Eurotron Microcal 2000+ Datasheet
Eurotron Microcal 2000+ Datasheet
Eurotron Microcal 2000+ Datasheet
Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from
all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.
We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. As such, we fully test & refurbish equipment in our in-house,
traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 1
year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of
combined experience, which enables us to deliver industry-leading service and support. We
endeavour to be customer focused in every way right down to the detail, such as offering free
delivery on sales, presenting flexible technical + commercial solutions and supplying a loan
unit during warranty repair, if available.
As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.
We are based at Aldermaston in the UK from where we supply test equipment worldwide.
Our facility incorporates Sales, Support, Admin, Logistics and our own in-house Lab.
- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our 40GHz in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.
Email: info@TestEquipmentHQ.com
Web: www.TestEquipmentHQ.com
MULTIFUNCTION MicroCal
Accurate and Reliable
CALIBRATORS
365 Days a Year
MicroCal 200/200+
Table IN - OUT Range MicroCal 2000+
High Accuracy
Sensor or Total range Accuracy Range Resolution
MicroCal 200
Accuracy
MicroCal 200+
Accuracy
MicroCal 2000+
Resolution Accuracy
Multifunctional Process Calibrators
parameter (% of rdg) (% of rdg) (% of rdg)
Tc J -210 ... 1200°C -190 ... 1200°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-350 ... 2200°F -310 ... 2192°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Tc K -270 ... 1370°C -160 ... 1260°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
454 ... 2500°F -256 ... 2300°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Tc T -270 ... 400°C -130 ... 400°C 0.01°C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-454 ... 760°F -238 ... 752°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Tc R -50 ... 1760°C 150 ... 1760°C 0.1 °C ±(0.02% + 0.2 °C) ± (0.01% + 0.2 °C) 0.01°C ±(0.005% + 0.2 °C)
-60 ... 3200°F 302 ... 3200°F 0.1 °F ±(0.02% + 0.36°F) ± (0.01% + 0.36 °F) 0.1 °F ±(0.005% + 0.36°F)
Tc S -50 ... 1760°C 170 ... 1760°C 0.1 °C ±(0.02% + 0.2 °C) ± (0.01% + 0.2 °C) 0.01°C ±(0.005% + 0.2 °C)
-60 ... 3200°F 338 ... 3200°F 0.1 °F ±(0.02% + 0.36°F) ± (0.01% + 0.36 °F) 0.1 °F ±(0.005% + 0.36°F)
MULTIFUNCTION
Tc B 50 ... 1820°C 920 ... 1820°C 0.1 °C ±(0.02% + 0.3 °C) ± (0.01% + 0.3 °C) 0.01°C ±(0.01% + 0.3 °C) CALIBRATORS
140 ... 3310°F 1688 ... 3308°F 0.1 °F ±(0.02% + 0.54°F) ± (0.01% + 0.54 °F) 0.1 °F ±(0.01% + 0.54°F)
Tc C 0 ... 2300°C 0 ... 2000°C 0.1 °C ±(0.02% + 0.2 °C) ± (0.01% + 0.2 °C) 0.1 °C ±(0.01% + 0.2 °C)
32 ... 4172°F 32 ... 3632°F 0.1 °F ±(0.02% + 0.36°F) ± (0.01% + 0.36 °F) 0.1 °F ±(0.01% + 0.36 °F)
Tc G 0 ... 2300°C 190 ... 2300°C 0.1 °C ±(0.02% + 0.3 °C) ± (0.01% + 0.3 °C) 0.1 °C ±(0.01% + 0.3 °C)
32 ... 4172°F 374 ... 4172°F 0.1 °F ±(0.02% + 0.54°F) ± (0.01% + 0.54 °F) 0.1 °F ±(0.01% + 0.54 °F)
Portable, Rugged and
Tc D 0 ... 2300°C 0 ... 2130°C 0.1 °C ±(0.02% + 0.3 °C) ± (0.01% + 0.3 °C) 0.1 °C ±(0.01% + 0.3 °C)
32 ... 4172°F 32 ... 3866°F 0.1 °F ±(0.02% + 0.54°F) ± (0.01% + 0.54 °F) 0.1 °F ±(0.01% + 0.54 °F) Easy to Use
Tc U -200 ... 400°C -160 ... 400°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-330 ... 760°F -256 ... 752°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F) Measures and Sources 14 Type
Tc L -200 ... 760°C -200 ... 760°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
of TCs and 10 RTDs
-330 ... 1400°F -328 ... 1400°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Tc N -270 ... 1300°C 0 ... 1300°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-450 ... 2380°F 32 ... 2372°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F) 24 Vdc Loop Power Supply
Tc E -270 ... 1000°C -200 ... 1000°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-454 ... 1840°F -328 ... 1832°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
In-Line Digit Setting
Tc F 0 ... 1400°C 0 ... 1400°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
32 ... 2560°F 32 ... 2552°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Pannel Mounting Kit
Pt100 IEC -200 ... 850°C -200 ... 850°C 0.01°C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.01°C ±(0.005% + 0.05°C)
OIML, a 3926 -330 ... 1570°F -328 ... 1562°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.005% + 0.09°F)
MicroCal PM200
Pt100 -200 ... 650°C -200 ... 650°C 0.01°C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.01°C ±(0.005% + 0.05°C)
a 3902 -330 ... 1210°F -328 ... 1210°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.005% + 0.09°F) Optional Module
Pt100 JIS -200 ... 600°C -200 ... 600°C 0.01°C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.01°C ±(0.005% + 0.05°C) to Generate/Measure Pressure
SAMA -330 ... 1120°F -328 ... 1112°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.005% + 0.09°F)
Pt 200 -200 ... 850°C -200 ... 850°C 0.1 °C ±(0.02% + 0.15°C) ± (0.01% + 0.15 °C) 0.01°C ±(0.005% + 0.15°C)
CalpMan 2007
-330 ... 1570°F -328 ... 1562°F 0.1 °F ±(0.02% + 0.27°F) ± (0.01% + 0.27 °F) 0.1 °F ±(0.005% + 0.27°F)
Pt 500 -200 ... 850°C -200 ... 530°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C) Software for Automatic
-330 ... 1570°F -328 ... 986°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F) Calibration and Documenting in
Pt1000 IEC -200 ... 850°C -200 ... 850°C 0.01°C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C) Compliance with ISO9001
OIML -330 ... 1570°F -328 ... 1562°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
CU10 -70 ... 150°C -70 ... 150°C 0.1 °C ±(0.02% + 0.4 °C) ± (0.01% + 0.4 °C) 0.1 °C ±(0.01% + 0.4 °C)
-100 ... 310°F -94 ... 302°F 0.1 °F ±(0.02% + 0.72°F) ± (0.01% + 0.72 °F) 0.1 °F ±(0.01% + 0.72°F)
CU100 -180 ... 150°C -180 ... 150°C 0.1 °C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.1 °C ±(0.01% + 0.05°C)
-300 ... 310°F -292 ... 302°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.01% + 0.09°F)
Ni100 -60 ... 180°C -60 ... 180°C 0.1 °C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.1 °C ±(0.01% + 0.05°C)
-80 ... 360°F -76 ... 356°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.01% + 0.09°F)
Ni120 0 ... 150°C 0 ... 150°C 0.1 °C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.1 °C ±(0.01% + 0.05°C)
32 ... 310°F 32 ... 302°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.01% + 0.09°F)
0 ... 5000 Ω 0.01 Ω ±(0.02% +120 mΩ ) ± (0.01% +120 mΩ ) 0.01 Ω ±(0.005% +120 mΩ )
b le C alibrat
Ω
OUT 0 ... 500 Ω 1 mΩ ±(0.02% + 20 mΩ ) ± (0.01% + 20 mΩ ) 1 mΩ ±(0.005% + 12 mΩ )
Por t a y!
5000 Ω 0.01 Ω 0.01 Ω le Toda
Availab
0 ... ±(0.02% +200 mΩ ) ± (0.01% +200 mΩ ) ±(0.005% +120 mΩ )
Frequency 1 ... 200 Hz 0.001 Hz ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) 0.001 Hz ±(0.005% + 0.001 Hz)
1 ... 2000 Hz 0.01 ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) 0.01 Hz ±(0.005% + 0.001 Hz)
1 ... 20000 Hz 0.1 Hz ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) 0.1 Hz ±(0.005% + 0.001 Hz)
Pulse counter
6
0 ... 10 counts 1 count infinite infinite 1 count infinite
Instrum
Pulse (Out) 0 ... 6000 pulse/min 1 pulse/min 1 pulse / min 1 pulse / min 1 pulse / min 1 pulse / min ron e
ot
Q
nt
0 ... 36000 pulse/h 1 pulse/h 1 pulse / min 1 pulse / min 1 pulse / h 1 pulse / min
r
Eu
Note: • The MicroCal 2000+ relative accuracies shown above are stated for 360 • Typical 2 years relative accuracy can be estimated by multiplying the “% of
Ce
m
ste
• The MicroCal 200/200+ relative accuracies shown above are stated for 360 days and the operative conditions are from +70°F to +77°F reading" specifications by 1.4. fie
rti
y
days and the operative conditions are from +64°F to +82°F • Typical 90 days relative accuracy can be estimated by dividing the "% of • All input ranges: additional error ±1 digit. d Quality S
reading" specifications by 1.6. • Eurotron traceability chart and uncertainty can be supplied on request.
www.eurotron.com
12 All descriptions are related to a fully optioned instrument. See last page for the different configurations
MULTIFUNCTION
MicroCal MicroCal MULTIFUNCTION
CALIBRATORS To Keep your Test and Process Equipment High Technology for Daily Use CALIBRATORS
Accurately Calibrated for ISO 9000 Compliance in Field and Laboratory
General SPECIFICATIONS
The MicroCal 200/200+ and MicroCal 2000+ are multifunctional calibrators IN/OUT parameters: Signal type: mV, V, mA, Ω , KΩ , frequency, pulses
with insulated channels. The instruments are portable and developed to meet thermocouples type: J, K, T, R, S, B, N, C, E, U, L, F, G, D
the needs of instrumentation engineers and Quality managers, both in resistance thermometers: Pt100 IEC, OIML, USLAB, US, SAMA, JIS, Pt200, 500,
1000, 1000 OIML, Ni100, Ni120, Cu10, Cu100
laboratory and in field work. Reference junction compensation: internal automatic: from -10 °C to +55 °C (14°F to 130°F)
This units are accurate, rugged, compact and easy to use. They are the ideal external adjustable: from -50 °C to +100 °C (-58°F to 210°F)
solution to simulate and measure simultaneously: Voltage, current, resistance, remote with external Pt100: from -10°C to +100 °C (14°F to 210°F)
thermocouple, resistance thermometers, frequency and pulse. Rj compensation drift: ± 0.015°C/°C (from -10 °C to +55 °C)
Rj compensation error: internal : ±0.15°C (±0.3°F)
Advanced flexibility and high performance has been achieved using a 32 bit remote : ±0.3°C (±0.6°F)
microprocessor and a fast A/D conversion technology. The calibrator’s internal Common mode rejection: >140 dB at ac operation
memory stores all data for normalized IEC, DIN and JIS thermoelectric sensors Normal mode rejection: >70 dB at 50 or 60 Hz
Temperature stability: MicroCal 200/200+: for temperature exceeding the band +18°C to +28°C (from +64 °C to +84 °F)
for both IPTS68 and ITS90 International Temperature Scale
full scale: ± 8 ppm/°C
zero: ± 0.2 mV /°C
MicroCal 2000+: for temperature exceeding the band +21°C to +25°C (from +70 °C to +77 °F)
The microprocessor performs automatic Table top
=
full scale: ± 3 ppm/°C
linearization and cold junction The case is equipped with 2 pivot feet to zero: ± 0.2 mV /°C
compensation to assure high accuracy. It is change the vertical viewing angle when Output impedance (emf output): < 0.5 Ω with 0.5 mA maximum current
possible to set the calibrator to execute using the instrument on the top of a table.
Input impedance (mV, V and Tc ranges): >10 MΩ
menu-driven calibration procedures for Input impedance (mA ranges): <140 Ω @ 1 mA
your instruments in field work. Quality System Source resistance effects: ±1 mV error for 1000 Ω source resistance
Research, development, production, Rtd and Ω simulation excitation current: MicroCal 200/200+: from 0.01 to 5 mA
Both Channel 1 (Out) and Channel 2 (In) inspection and certification activities are MicroCal 2000+: from 0.01 to 2 mA
have the following operative mode defined by methods and procedures of the Rtd and Ω
measurement excitation current: ~ 0.4 mA @ 400Ω
capabilities: Eurotron Quality System inspected for ~ 0.04 mA @ 4000Ω
= millivolts compliance and certified ISO9001 by Rtd connection: 2, 3, and 4 wires
= volts GASTEC, a Dutch notified body. Rtd cable compensation: up to 100 Ω (each wire)
= milliamperes (active and passive loop) Rtd cable compensation error (Pt100): ±0.005°C/ Ω of total wire
= Ohms EMC Conformity Maximum load resistance: 1000 Ω @ 20 mA
= temperature with thermocouples Display: graphic LCD 240 x 64 dots display with LED backlight device
The instrument case, made in shock-
= temperature with resistance Measurement sampling time: 250 ms
resistant injection molded ABS + Output noise (at 300 Hz): <2 mVpp for ranges up to 200 mV f.s.,
thermometers polycarbonate has an internal metal <10 mVpp for ranges up to 2 V f.s.
= frequency
coating to fulfill the prevision of the directive <80 mVpp for ranges up to 20 V f.s.
= pulse
89/336/CEE Electromagnetic Digital interface: full bidirectional TTL (a RS232 adapter normal or insulated, is available as an option)
Compatibility. Channel 1_Channel 2 insulation: 50 Vdc
Remote auxiliary inputs are available for: Calculation functions: hold, max, min, offset, average
Relative humidity
= and temperature Selection °C/°F/K: through the configuration procedure
module In/Out data memory: 20 data with manual or automatic recall
= Two internal sensors and built-in hand Logging mode: 1500 input data items (optional memory card for memory extension)
pump pressure module Convert function: displays the electrical equivalent of the engineering unit
Scale factor: 5 different settings with zero and span programmable within -399999 and +999999
The ergonomic case design allows the user Square root: in combination with scale factor
Calibration: self learning technique with automatic procedure
the calibrator in three different ways:
Power supply: external charger and rechargeable Ni-Cd battery
= Portable
Self contained operation: 6h on Tc and mV input/output (backlight Off)
Two different leather cases, with a cover 3.5h with 20 mA simulation (backlight Off)
and shoulder strap, are available upon Recharging time: 5h at 90% and 6h at 99% with instrument switched off.
request for instrument alone or The battery charging is active only with the instrument switched off.
instrument, printer and accessories. Line operation: 100 - 120 - 230 Vac through the external battery charger
These are extremely useful for practical Line transformer insulation: 2500 Vac
use since they leave one hand free for Firmware release identification: release code on the display
instrument tuning. Operating environment temperature range: from -10 °C to +55 °C (from 14 °C to 130 °F)
= Panel mounting Storage temperature range: from -30 °C to +60 °C (from -22 °C to 140 °F)
It requires a panel cutout of 9.7” x 3.5”. Case: Injection moulded ABS with internal metal coating
The instrument bezel flange butts against Dimensions: 264 x 96 x 172 mm (10.4”x3.8”x6.8”) DIN size
the front of the mounting plate; two Weights: nett: 8.8 lb. gross: 12.1 lb.
lateral mounting brackets fit over the
instrument rear panel
6 11
MicroCal 200/200+ MULTIFUNCTION
CALIBRATORS
MicroCal 2000+
"Excellence in measurements"
Instrument Highlight
MicroCal 200/200+
6 digit display
MicroCal 2000+
6 ½ digit display
7
MULTIFUNCTION MicroCal 200/200+
CALIBRATORS MicroCal 2000+
Firmware
The firmware is stored inside a flash
memory and allows a fast and easy
upgrade of the instrument using a
standard PC. Firmware includes the
following capabilities:
• multiple measurement and
generation mode
• signal processing: filter, average,
min, max
• PC downloadable test procedure
• DataLogger and graphic recorder
• switch test routine
• ramping and stepping for dynamic
testing
• user definable linearization
• user entry of probe specific
calibration coefficients.
8
MicroCal MULTIFUNCTION
To Document the Inspection CALIBRATORS
"Excellence in measurements" and Calibration Activities
ORDERING CODE
MicroCal 2000+
End
step 3928 - A - B - C - D
Each instrument is supplied with USB cable, PC
Software Package (Linman, Logman), leather
carrying case with shoulder strap, Report of Calibration
and instruction manual.
9
MULTIFUNCTION
MicroCal
CALIBRATORS Easy to use
Easy to Order
Calibration IN
Procedure 5.01 bar
InP
ç
ç 5.00 bar
10
MULTIFUNCTION
MicroCal MicroCal MULTIFUNCTION
CALIBRATORS To Keep your Test and Process Equipment High Technology for Daily Use CALIBRATORS
Accurately Calibrated for ISO 9000 Compliance in Field and Laboratory
General SPECIFICATIONS
The MicroCal 200/200+ and MicroCal 2000+ are multifunctional calibrators IN/OUT parameters: Signal type: mV, V, mA, Ω , KΩ , frequency, pulses
with insulated channels. The instruments are portable and developed to meet thermocouples type: J, K, T, R, S, B, N, C, E, U, L, F, G, D
the needs of instrumentation engineers and Quality managers, both in resistance thermometers: Pt100 IEC, OIML, USLAB, US, SAMA, JIS, Pt200, 500,
1000, 1000 OIML, Ni100, Ni120, Cu10, Cu100
laboratory and in field work. Reference junction compensation: internal automatic: from -10 °C to +55 °C (14°F to 130°F)
This units are accurate, rugged, compact and easy to use. They are the ideal external adjustable: from -50 °C to +100 °C (-58°F to 210°F)
solution to simulate and measure simultaneously: Voltage, current, resistance, remote with external Pt100: from -10°C to +100 °C (14°F to 210°F)
thermocouple, resistance thermometers, frequency and pulse. Rj compensation drift: ± 0.015°C/°C (from -10 °C to +55 °C)
Rj compensation error: internal : ±0.15°C (±0.3°F)
Advanced flexibility and high performance has been achieved using a 32 bit remote : ±0.3°C (±0.6°F)
microprocessor and a fast A/D conversion technology. The calibrator’s internal Common mode rejection: >140 dB at ac operation
memory stores all data for normalized IEC, DIN and JIS thermoelectric sensors Normal mode rejection: >70 dB at 50 or 60 Hz
Temperature stability: MicroCal 200/200+: for temperature exceeding the band +18°C to +28°C (from +64 °C to +84 °F)
for both IPTS68 and ITS90 International Temperature Scale
full scale: ± 8 ppm/°C
zero: ± 0.2 mV /°C
MicroCal 2000+: for temperature exceeding the band +21°C to +25°C (from +70 °C to +77 °F)
The microprocessor performs automatic Table top
=
full scale: ± 3 ppm/°C
linearization and cold junction The case is equipped with 2 pivot feet to zero: ± 0.2 mV /°C
compensation to assure high accuracy. It is change the vertical viewing angle when Output impedance (emf output): < 0.5 Ω with 0.5 mA maximum current
possible to set the calibrator to execute using the instrument on the top of a table.
Input impedance (mV, V and Tc ranges): >10 MΩ
menu-driven calibration procedures for Input impedance (mA ranges): <140 Ω @ 1 mA
your instruments in field work. Quality System Source resistance effects: ±1 mV error for 1000 Ω source resistance
Research, development, production, Rtd and Ω simulation excitation current: MicroCal 200/200+: from 0.01 to 5 mA
Both Channel 1 (Out) and Channel 2 (In) inspection and certification activities are MicroCal 2000+: from 0.01 to 2 mA
have the following operative mode defined by methods and procedures of the Rtd and Ω
measurement excitation current: ~ 0.4 mA @ 400Ω
capabilities: Eurotron Quality System inspected for ~ 0.04 mA @ 4000Ω
= millivolts compliance and certified ISO9001 by Rtd connection: 2, 3, and 4 wires
= volts GASTEC, a Dutch notified body. Rtd cable compensation: up to 100 Ω (each wire)
= milliamperes (active and passive loop) Rtd cable compensation error (Pt100): ±0.005°C/ Ω of total wire
= Ohms EMC Conformity Maximum load resistance: 1000 Ω @ 20 mA
= temperature with thermocouples Display: graphic LCD 240 x 64 dots display with LED backlight device
The instrument case, made in shock-
= temperature with resistance Measurement sampling time: 250 ms
resistant injection molded ABS + Output noise (at 300 Hz): <2 mVpp for ranges up to 200 mV f.s.,
thermometers polycarbonate has an internal metal <10 mVpp for ranges up to 2 V f.s.
= frequency
coating to fulfill the prevision of the directive <80 mVpp for ranges up to 20 V f.s.
= pulse
89/336/CEE Electromagnetic Digital interface: full bidirectional TTL (a RS232 adapter normal or insulated, is available as an option)
Compatibility. Channel 1_Channel 2 insulation: 50 Vdc
Remote auxiliary inputs are available for: Calculation functions: hold, max, min, offset, average
Relative humidity
= and temperature Selection °C/°F/K: through the configuration procedure
module In/Out data memory: 20 data with manual or automatic recall
= Two internal sensors and built-in hand Logging mode: 1500 input data items (optional memory card for memory extension)
pump pressure module Convert function: displays the electrical equivalent of the engineering unit
Scale factor: 5 different settings with zero and span programmable within -399999 and +999999
The ergonomic case design allows the user Square root: in combination with scale factor
Calibration: self learning technique with automatic procedure
the calibrator in three different ways:
Power supply: external charger and rechargeable Ni-Cd battery
= Portable
Self contained operation: 6h on Tc and mV input/output (backlight Off)
Two different leather cases, with a cover 3.5h with 20 mA simulation (backlight Off)
and shoulder strap, are available upon Recharging time: 5h at 90% and 6h at 99% with instrument switched off.
request for instrument alone or The battery charging is active only with the instrument switched off.
instrument, printer and accessories. Line operation: 100 - 120 - 230 Vac through the external battery charger
These are extremely useful for practical Line transformer insulation: 2500 Vac
use since they leave one hand free for Firmware release identification: release code on the display
instrument tuning. Operating environment temperature range: from -10 °C to +55 °C (from 14 °C to 130 °F)
= Panel mounting Storage temperature range: from -30 °C to +60 °C (from -22 °C to 140 °F)
It requires a panel cutout of 9.7” x 3.5”. Case: Injection moulded ABS with internal metal coating
The instrument bezel flange butts against Dimensions: 264 x 96 x 172 mm (10.4”x3.8”x6.8”) DIN size
the front of the mounting plate; two Weights: nett: 8.8 lb. gross: 12.1 lb.
lateral mounting brackets fit over the
instrument rear panel
6 11
MULTIFUNCTION MicroCal
Accurate and Reliable
CALIBRATORS
365 Days a Year
MicroCal 200/200+
Table IN - OUT Range MicroCal 2000+
High Accuracy
Sensor or Total range Accuracy Range Resolution
MicroCal 200
Accuracy
MicroCal 200+
Accuracy
MicroCal 2000+
Resolution Accuracy
Multifunctional Process Calibrators
parameter (% of rdg) (% of rdg) (% of rdg)
Tc J -210 ... 1200°C -190 ... 1200°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-350 ... 2200°F -310 ... 2192°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Tc K -270 ... 1370°C -160 ... 1260°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
454 ... 2500°F -256 ... 2300°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Tc T -270 ... 400°C -130 ... 400°C 0.01°C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-454 ... 760°F -238 ... 752°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Tc R -50 ... 1760°C 150 ... 1760°C 0.1 °C ±(0.02% + 0.2 °C) ± (0.01% + 0.2 °C) 0.01°C ±(0.005% + 0.2 °C)
-60 ... 3200°F 302 ... 3200°F 0.1 °F ±(0.02% + 0.36°F) ± (0.01% + 0.36 °F) 0.1 °F ±(0.005% + 0.36°F)
Tc S -50 ... 1760°C 170 ... 1760°C 0.1 °C ±(0.02% + 0.2 °C) ± (0.01% + 0.2 °C) 0.01°C ±(0.005% + 0.2 °C)
-60 ... 3200°F 338 ... 3200°F 0.1 °F ±(0.02% + 0.36°F) ± (0.01% + 0.36 °F) 0.1 °F ±(0.005% + 0.36°F)
MULTIFUNCTION
Tc B 50 ... 1820°C 920 ... 1820°C 0.1 °C ±(0.02% + 0.3 °C) ± (0.01% + 0.3 °C) 0.01°C ±(0.01% + 0.3 °C) CALIBRATORS
140 ... 3310°F 1688 ... 3308°F 0.1 °F ±(0.02% + 0.54°F) ± (0.01% + 0.54 °F) 0.1 °F ±(0.01% + 0.54°F)
Tc C 0 ... 2300°C 0 ... 2000°C 0.1 °C ±(0.02% + 0.2 °C) ± (0.01% + 0.2 °C) 0.1 °C ±(0.01% + 0.2 °C)
32 ... 4172°F 32 ... 3632°F 0.1 °F ±(0.02% + 0.36°F) ± (0.01% + 0.36 °F) 0.1 °F ±(0.01% + 0.36 °F)
Tc G 0 ... 2300°C 190 ... 2300°C 0.1 °C ±(0.02% + 0.3 °C) ± (0.01% + 0.3 °C) 0.1 °C ±(0.01% + 0.3 °C)
32 ... 4172°F 374 ... 4172°F 0.1 °F ±(0.02% + 0.54°F) ± (0.01% + 0.54 °F) 0.1 °F ±(0.01% + 0.54 °F)
Portable, Rugged and
Tc D 0 ... 2300°C 0 ... 2130°C 0.1 °C ±(0.02% + 0.3 °C) ± (0.01% + 0.3 °C) 0.1 °C ±(0.01% + 0.3 °C)
32 ... 4172°F 32 ... 3866°F 0.1 °F ±(0.02% + 0.54°F) ± (0.01% + 0.54 °F) 0.1 °F ±(0.01% + 0.54 °F) Easy to Use
Tc U -200 ... 400°C -160 ... 400°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-330 ... 760°F -256 ... 752°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F) Measures and Sources 14 Type
Tc L -200 ... 760°C -200 ... 760°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
of TCs and 10 RTDs
-330 ... 1400°F -328 ... 1400°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Tc N -270 ... 1300°C 0 ... 1300°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-450 ... 2380°F 32 ... 2372°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F) 24 Vdc Loop Power Supply
Tc E -270 ... 1000°C -200 ... 1000°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
-454 ... 1840°F -328 ... 1832°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
In-Line Digit Setting
Tc F 0 ... 1400°C 0 ... 1400°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C)
32 ... 2560°F 32 ... 2552°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
Pannel Mounting Kit
Pt100 IEC -200 ... 850°C -200 ... 850°C 0.01°C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.01°C ±(0.005% + 0.05°C)
OIML, a 3926 -330 ... 1570°F -328 ... 1562°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.005% + 0.09°F)
MicroCal PM200
Pt100 -200 ... 650°C -200 ... 650°C 0.01°C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.01°C ±(0.005% + 0.05°C)
a 3902 -330 ... 1210°F -328 ... 1210°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.005% + 0.09°F) Optional Module
Pt100 JIS -200 ... 600°C -200 ... 600°C 0.01°C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.01°C ±(0.005% + 0.05°C) to Generate/Measure Pressure
SAMA -330 ... 1120°F -328 ... 1112°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.005% + 0.09°F)
Pt 200 -200 ... 850°C -200 ... 850°C 0.1 °C ±(0.02% + 0.15°C) ± (0.01% + 0.15 °C) 0.01°C ±(0.005% + 0.15°C)
CalpMan 2007
-330 ... 1570°F -328 ... 1562°F 0.1 °F ±(0.02% + 0.27°F) ± (0.01% + 0.27 °F) 0.1 °F ±(0.005% + 0.27°F)
Pt 500 -200 ... 850°C -200 ... 530°C 0.1 °C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C) Software for Automatic
-330 ... 1570°F -328 ... 986°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F) Calibration and Documenting in
Pt1000 IEC -200 ... 850°C -200 ... 850°C 0.01°C ±(0.02% + 0.1 °C) ± (0.01% + 0.1 °C) 0.01°C ±(0.005% + 0.1 °C) Compliance with ISO9001
OIML -330 ... 1570°F -328 ... 1562°F 0.1 °F ±(0.02% + 0.18°F) ± (0.01% + 0.18 °F) 0.1 °F ±(0.005% + 0.18°F)
CU10 -70 ... 150°C -70 ... 150°C 0.1 °C ±(0.02% + 0.4 °C) ± (0.01% + 0.4 °C) 0.1 °C ±(0.01% + 0.4 °C)
-100 ... 310°F -94 ... 302°F 0.1 °F ±(0.02% + 0.72°F) ± (0.01% + 0.72 °F) 0.1 °F ±(0.01% + 0.72°F)
CU100 -180 ... 150°C -180 ... 150°C 0.1 °C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.1 °C ±(0.01% + 0.05°C)
-300 ... 310°F -292 ... 302°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.01% + 0.09°F)
Ni100 -60 ... 180°C -60 ... 180°C 0.1 °C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.1 °C ±(0.01% + 0.05°C)
-80 ... 360°F -76 ... 356°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.01% + 0.09°F)
Ni120 0 ... 150°C 0 ... 150°C 0.1 °C ±(0.02% + 0.05°C) ± (0.01% + 0.05 °C) 0.1 °C ±(0.01% + 0.05°C)
32 ... 310°F 32 ... 302°F 0.1 °F ±(0.02% + 0.09°F) ± (0.01% + 0.09 °F) 0.1 °F ±(0.01% + 0.09°F)
0 ... 5000 Ω 0.01 Ω ±(0.02% +120 mΩ ) ± (0.01% +120 mΩ ) 0.01 Ω ±(0.005% +120 mΩ )
b le C alibrat
Ω
OUT 0 ... 500 Ω 1 mΩ ±(0.02% + 20 mΩ ) ± (0.01% + 20 mΩ ) 1 mΩ ±(0.005% + 12 mΩ )
Por t a y!
5000 Ω 0.01 Ω 0.01 Ω le Toda
Availab
0 ... ±(0.02% +200 mΩ ) ± (0.01% +200 mΩ ) ±(0.005% +120 mΩ )
Frequency 1 ... 200 Hz 0.001 Hz ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) 0.001 Hz ±(0.005% + 0.001 Hz)
1 ... 2000 Hz 0.01 ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) 0.01 Hz ±(0.005% + 0.001 Hz)
1 ... 20000 Hz 0.1 Hz ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) 0.1 Hz ±(0.005% + 0.001 Hz)
Pulse counter
6
0 ... 10 counts 1 count infinite infinite 1 count infinite
Instrum
Pulse (Out) 0 ... 6000 pulse/min 1 pulse/min 1 pulse / min 1 pulse / min 1 pulse / min 1 pulse / min ron e
ot
Q
nt
0 ... 36000 pulse/h 1 pulse/h 1 pulse / min 1 pulse / min 1 pulse / h 1 pulse / min
r
Eu
Note: • The MicroCal 2000+ relative accuracies shown above are stated for 360 • Typical 2 years relative accuracy can be estimated by multiplying the “% of
Ce
m
ste
• The MicroCal 200/200+ relative accuracies shown above are stated for 360 days and the operative conditions are from +70°F to +77°F reading" specifications by 1.4. fie
rti
y
days and the operative conditions are from +64°F to +82°F • Typical 90 days relative accuracy can be estimated by dividing the "% of • All input ranges: additional error ±1 digit. d Quality S
reading" specifications by 1.6. • Eurotron traceability chart and uncertainty can be supplied on request.
www.eurotron.com
12 All descriptions are related to a fully optioned instrument. See last page for the different configurations