Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

TIRERTS

TESTING RESEARCH ENGINEERING AND TECHNOLOGICAL SERVICES


14, RAMANATH PAL ROAD, KIDDERPORE, KOLKATA - 700 023 X
TEL : 2459-4142/2459-6344, FAX : 2459-5818, E-mail : treats_kolkata@yahoo.com / treats @treats.co.in, Web : treats.co.in
(Government Registered)

TEST REPORT Page 1of 2


Test Report No. : T/CA&MT - 0523B/23-24 (R) Material Specification : 18:2062 - 2011
Date ¢ 01.08.2023 Description of samples : 02 nos. cut pieces of round bar
Name of Customer : Jaypee Engg.& Hydraulic Samples stamped as : Not stamped '
Equipment Co. Ltd.
Chandannagar, Budge Budge ~ Samples drawn by H The customer
Trunk Road,
24 Parganas (South) Samples received on : 04.07.2023
Reference : Challan dated 04.07.2023 Samples tested on 3 31.07.2023
Location of Testing : At our Laboratory
ULR No. : TC759723000002702F Environmental Conditions: Temp. 30°C / 58% R.H.

T R CHEMICAL ANALYSIS -
TEST METHOD: [O E S~ ASTM E 415-2021 & JIS G-1253/2013]
Customer’s Code Marking | % % % % % % % %
gid [¢ S P Ni Cr Mo v Cu
330mm Round Bar M1 0.195 0.038 [ 0.035 | 0236 | 0.162 | 0.060 | <0.001 | 0.131
i
AL It 1
280mm Round Bar R1 0.195 [ 069 [ 0.266 | 0.037 | 0.036 | 0.237 | 0.162 | 0.060 | <0.001 | 0.131
T | i | )
Specified : IS: 21 2011 0.22 0.045 | 0.045 | - - - - -
Grade E 250, Quality BR max | max | max | max | max

DRETEEAT i ~ MECHANICAL TESTING


TEST METHOD: [Tensile— IS: 1608(Part 1) 2022
& Brinell Hardness: IS: 1500 (Part— 1) 2019]
SL | Customer’s Code | Marking | 02%P.S. | T.S. | %Elon | % Rednin Brinell Hardness Value
No. MPa MPa_ | SOmmG.L. | area Avg. HBW(3000 kef load, 10mm¢ ball)
1| 330mmRound Bar | M1 302.05 | 507.076 29 47132 137
2. | 280mm Round Bar RI 303.21 49853 298 519 143
Specified : 1S: 2062 - 2011 230 MPa | 410 230 - -
Grade E 250, Quality BR min MPa min
% 2 I | min

Remarks: Samples meet the above specified chemical & mechanical requirements.
Test(s) Witnessed by: Not witnessed.

“Checked by: Mr. “Tarafder. \/,'_S_% For TREATS

(B.MISHRA)
TQF 041 Manager-Laboratory
1) This TestReport refers to the values obtai e time oftesting& resiiis relate to the ftem tesicd
2) This Report shall not be reproduced in part or full without written permissiori of the management,
3) All tests are performed as per specification / reference books
4) Samples are drawn by the customer/ TPI & not by us, unless otherwise specified.
5) Laboratory is not responsible for information provided by the customer incorporated in the Test Report
6) This Test Report is non-negotiable
7) Any discrepancy in this Test Report should be brought to “notice within 13 days from the date of issuance”
TRERTE
TESTING RESEARCH ENGINEERING AND TECHNOLOGICAL SERVICES
14, RAMANATH PAL ROAD, KIDDERPORE, KOLKATA - 700 023 .
TEL : 2459-4142/2459-6344, FAX : 2459-5818, E-mail : treats_kolkata@yahoo.com / treats @treats.co.in, Web : treals.co.in
(Government Registered)

TEST REPORT Page 20f 2


Test Report No. : T/CA&MT - 0523B/23-24 (R) Material Specification : 18:2062 - 2011
Date : 01.08.2023 Description of samples : 02 nos. cut pieces of round bar
Name of Customer : Jaypee Engg.& Hydraulic Samples stamped as : Not stamped
Equipment Co. Ltd.
Chandannagar, Budge Budge ~ Samples drawn by : The customer
Trunk Road,
24 Parganas (South) Samples received on : 04.07.2023
Reference : Challan dated 04.07.2023 Samples tested on : 31.07.2023

Location of Testing : At our Laboratory Environmental Conditions: Temp. 30°C / 58% R.H.

CHEMICAL ANALYSIS
TEST METHOD: [O E S - ASTM E 415 — 2021 & JIS G-1253/2013]
SI. Customer’s Code Marking %
No. CE#
1. 330mm Round Bar Mi 0.381

2, 280mm Round Bar R1 0380

Specified : IS: 2062 — 2011 - 0.41


Grade E 250, Quality BR max
#C.E.=C+Mn/6 +(Cr+ Mo+ V)/5+(Ni+Cu)/15

Remarks: Samples meet the above specified chemical & mechanical requirements.

Test(s) Witnessed by: Not witnessed.

Checked by: Mr. / K. Tarafder. /;S_—/L’mork For TREATS

(B.MISHRA)
Manager-Laboratory
Disclaimer : 1) This Test Report refers to the values obtained at the time of testing & results relate to the ftem tested.
2) This Report shall not be reproduced in part or full without written permission of the management.
3) Al tests are performed as per specification / reference books.
4) Samples are drawn by the customer/ TPI & not by us, unless otherwise specified.
) Laboratory is not responsible for information provided by the customer incorporated in the Test Report
6) This Test Report s non-negotiable
7) Any discrepancy in this Test Report should be brought to “notice within 15 days from the date of issuance”.

You might also like