Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

V R B Steels 29-02-24

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

COMMANDO LAB

MATERIA L TESTING
IBR (TN) Govt. Registered Laboralory
Mechanlcal * Meltallography * Chemical Corrosion

PAGE: Iof | DATE: 29.02.2024


TEST REPORT No. CL/B/O78

TEST REPORT
Work Order No. : CUB/078 CUSTOMER DETAILS:
Received on 29.02.2024 M/s. VRB STEELS
Tested on 29.02.2024 BRANCH: S.F.No. I59, Karuvalur Main Road,
Test Method IS 1608-1:2022 Manichampalayam, Coimbatore-64 | 107.
Deviation from the method NIL Customer Ref.: Yr. Lt. Dt:29.02.2024
SAMPLE DESCRIPTION
Sheet Coil No. :3V5507000S
Description
Size :1.20mm Thick Specification : IS 513 PART-1-2016CR2
Heat No. :23203274
DETAILS OF TESTING FACILITY
: 27.10.2024
Machine No. CLIME/UTMEO1 Validity
: 25.2
Model TUE-CN-400 Ambient Temp.°C
Capacity 400 kN
TENSILE TEST RESULTS

Specimen Size Y.S UTS %


Batch ID Mpa EL
No Width Thick GL Area Mpa
M1m Imm mm mm
15.25 228.46 332.68 32.18
1. A23J12A009 12.50 1.22 50.00

50.00 15.48 225.68 329.18 33.15


2. A23J12A011 12.48 1.24

A23J12A013 12.51 1.21 50.00 15.14 210.68 307.55 36.14


3

Requirement Values 140-240 270-370 30 Min

Remarks: The above sample conforms to IS S13 PART-1-2016 CR2


Tested By Authorised By

(E.RAMAR) (A.SARAVANAKUMAR)
Testing Engineer Quality Manager
Note: (Y.S - Yield Strength, UTS -Ultimate Tensile Strength, EL-Elongation , RA- Reduction Area )
NOTE:
not drawn by us.
1. This report refers only to the particular sample(s) submitted for testing and the sample was of an approved abstract has
2. This report shall not be reproduced expect in full, unless written permission for the publication
been obtained from the Managing Partner, Commando Lab.
conditions of measurement.
3. The results reported in this report are valid at the time of under the stated
4. Correction or attestation if any invalidate this report. This report strictly confidential & its use for publicity, arbitration or as
evidence in legal disputes if forbidden.
CLFME01/00.02/08. 18
END OF TEST REPORT.

No. 3A, 5th South Street, Avarampalayam, Coimbatore -641 006.


Ph:0422 - 2560907 Mob:99430 14772, 99430 33225 E-mail : commandolab@gmail.com, Web:www.commandolab.com