PRODUCT

Correction Reissue

NEWS Product Discontinuation


Notices
Issue Date
October 1, 2021
Inverters No. 2021E006C(2)

Discontinuation Notice of High-function General-purpose Inverter


3G3RX-[]-E1F (For Europe area only).

<< REQUEST >>


There was modification in portion of Product Discontinuation notices of Product News No. 2021E006C of May 2021
issue. What we have changed is as follows; Change [ Final order entry date ], [ Date of The Last Shipping ] and
[ Scheduled date of maintenance close ].
Please abolish old edition, replace the latest No. 2021E006C(2).

Product Discontinuation Recommended Replacement


High-function General-purpose Inverter High-function General-purpose Inverter
Model 3G3RX-[]-E1F Model 3G3RX2-[]

[ Final order entry date ]


The end of August, 2022
Note: Discontinuation date of network options is the end of March, 2029.

[ Date of The Last Shipping ]


The end of August, 2022

[ Scheduled date of maintenance close ]


The end of August, 2029

[ Caution on recommended replacement ]


(1) Mounting dimensions of 3G3RX-[]-E1F and 3G3RX2-[] are same. Not need to additional hole.
(2) Name, arrangement and wiring for the main circuit terminal block and the control circuit terminal
block have some differences.
(3) Default parameter value and parameter functions have some differences between 3G3RX-[]-E1F and
3G3RX2-[].
(4) PG option board and network option for 3G3RX-[]-E1F can’t be used for 3G3RX2-[].
(5) The operator for 3G3RX-[]-E1F has 4digit LED display however 3G3RX2-[] have LCD display.
Operation will be improved.
(6) 3G3RX-[]-E1F have 3G3RX-A4004-E1F (400V class 0.4kw capacitor). However 3G3RX2-[] doesn’t
have 3G3RX2-A4004. So please to be replaced by 3G3RX2-A4007.
(7) The default setting of the control circuit is source logic, which is different from the 3G3RX-[]-E1F.
Make sure that the switch setting matches the circuit after wiring before turning ON power.
(8) Although the built-in EMC noise filter of 3G3RX-[]-E1F is disabled as default, that of 3G3RX2-[] is
enabled as default.
Disable the EMC filter by changing the wiring of the EMC filter in some of the following cases:
- When an external noise filter is used
- When the built-in EMC noise filter is used in a power supply environment different from that of
Europe

OMRON Corporation Industrial Automation Company No. B-211709


[ Difference from discontinued product ]
Recommended Body Dimen- Wire Mounting Charac- Operation Operation
replacement Model Color sions connection Dimensions teristics ratings methods
3G3RX2-[] ** * -- ** * * --
** : Compatible
* : The change is a little/Almost compatible
-- : Not compatible
- : No corresponding specification

[ Product Discontinuation and recommended replacement ]


Product discontinuation Recommended replacement
3G3RX-A2004-E1F 3G3RX2-A2004
3G3RX-A2007-E1F 3G3RX2-A2007
3G3RX-A2015-E1F 3G3RX2-A2015
3G3RX-A2022-E1F 3G3RX2-A2022
3G3RX-A2037-E1F 3G3RX2-A2037
3G3RX-A2055-E1F 3G3RX2-A2055
3G3RX-A2075-E1F 3G3RX2-A2075
3G3RX-A2110-E1F 3G3RX2-A2110
3G3RX-A2150-E1F 3G3RX2-A2150
3G3RX-A2185-E1F 3G3RX2-A2185
3G3RX-A2220-E1F 3G3RX2-A2220
3G3RX-A2300-E1F 3G3RX2-A2300
3G3RX-A2370-E1F 3G3RX2-A2370
3G3RX-A2450-E1F 3G3RX2-A2450
3G3RX-A2550-E1F 3G3RX2-A2550
3G3RX-A4004-E1F 3G3RX2-A4007
3G3RX-A4007-E1F 3G3RX2-A4007
3G3RX-A4015-E1F 3G3RX2-A4015
3G3RX-A4022-E1F 3G3RX2-A4022
3G3RX-A4040-E1F 3G3RX2-A4037
3G3RX-A4055-E1F 3G3RX2-A4055
3G3RX-A4075-E1F 3G3RX2-A4075
3G3RX-A4110-E1F 3G3RX2-A4110
3G3RX-A4150-E1F 3G3RX2-A4150
3G3RX-A4185-E1F 3G3RX2-A4185
3G3RX-A4220-E1F 3G3RX2-A4220
3G3RX-A4300-E1F 3G3RX2-A4300
3G3RX-A4370-E1F 3G3RX2-A4370
3G3RX-A4450-E1F 3G3RX2-A4450
3G3RX-A4550-E1F 3G3RX2-A4550
3G3RX-B4750-E1F 3G3RX2-B4750
3G3RX-B4900-E1F 3G3RX2-B4900
3G3RX-B411K-E1F 3G3RX2-B411K
3G3RX-B413K-E1F 3G3RX2-B413K

2
[ Body color ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-[]-E1F 3G3RX2-[]
Black. Black.

[ Wire connection ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-[]-E1F 3G3RX2-[]
Circuit Diagram Main Circuit Diagram

Control Circuit Diagram

[ Difference of Terminal Block ]


Main Circuit Terminal Block
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
Terminal Terminal name Terminal Terminal name
PD/+1 External DC reactor terminal PD DC reactor connection terminal
Connection terminal for regenerative
P/+ Braking resistor connection terminal P
braking unit

3
[ Difference of Terminal Block ]
Control Circuit Terminal Block
Product discontinuation Recommendable replacement
Item
Model 3G3RX-[]-E1F Model 3G3RX2-[]
By factory default, the terminal FW and the
multi-function input terminals are set to sink logic
Changing (NPN).
You can switch between the sink logic and
input To change the input control logic to source logic
source logic for input terminals by using SW6.
control (PNP), remove the short-circuit bar between the
(The default setting is source logic.)
logic terminals P24 and PLC on the control circuit
terminal block, and connect it between the
terminals PLC and CM1.
- Backup 24 V power supply terminal
Additional
- 1a relay terminal
function
- Function safety terminal

Product discontinuation Recommendable replacement


Model 3G3RX-[]-E1F Model 3G3RX2-[] Remarks
Terminal Terminal name Terminal Terminal name
Frequency
Power supply for
H reference power H
setting speed
supply output
Frequency On 3G3RX-E1F, O is specified for
reference input voltage input.
O
(Voltage Analog input And OI is specified for current input.
reference) Ai1 terminal 1/2 On 3G3RX2, for Ai1 and Ai2, 0-10VDC
Frequency Ai2 (voltage/current voltage input and 0-20mA current input
reference input switching SW 1/2) can be switched using a switch for use.
OI It can be used for input frequency
(Current
reference) command or feedback.
Auxiliary
frequency
Analog input
O2 reference input Ai3
terminal 3
(Voltage
reference)
Frequency
Analog power
L reference L
Common
common
Multi-function On 3G3RX-E1F, AM is specified for
AM analog output voltage output.
(Voltage) Analog output And AMI is specified for current output.
Ao1 terminal 1/2 On 3G3RX2, for Ao1 and Ao2, 0-10VDC
Ao2 (voltage/current voltage output and 0-20mA current
Multi-function switching SW 3/4) output can be switched using a switch
AMI analog output as output of information monitor data of
(Current) the inverter.
Multi-function Digital monitor
FM FM
digital output (voltage)
Sequence input Common for
CM1 CM1
common digital monitor

4
[ Difference of Terminal Block ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[] Remarks
Terminal Terminal name Terminal Terminal name
1 1
2 2
3 3
4 4
Multi-function input
5 5
6 6 Input terminal
7 7
8 8
Forward RUN On 3G3RX2, FW signal is set on the input
FW 9
command terminal terminal ”9”.
Multi-function input Common for input
PLC COM
common terminal
11 11
12 12
Multi-function
13 13 Output terminal
output
14 14
15 15
Multi-function Common for output
CM2 CM2
output common terminal
On 3G3RX-E1F, By factory default,
AL2 AL0 Multi-function Relay Output (AL2, AL1)
Multi-function relay
Operation Selection (C036) is set at NC
output Select
AL1 AL1 contact between AL2 and AL0, and NO
1c relay terminal contact between AL1 and AL0.
On 3G3RX2, by factory default,
Multi-function relay Relay output terminal function selection
AL0 AL2 a/b (NO/NC) selection (CC-17) is set at
output common
NO contact between AL0 and AL2.
External thermistor External thermistor
TH TH+
input terminal Input
- 16A NO contact relay added to 3G3RX2.
- 1a relay terminal You can select the function by setting the
- 16C parameter of output terminal 16.

[ Mounting dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
Mounting dimensions for 3G3RX-[]-E1F and 3G3RX2-[] are same.
Model Width Height Screw
A2004/A2007/A2015/A2022/A2037/A4004(3G3RX)/A4007/A4015/A4022/A4037 130 241 M5
A2055/A2075/A2110/A4055/A4075/A4110 189 246 M6
A2150/A2185/A2220/A4150/A4185/A4220 229 376 M6
A2300/A4300 265 510 M8
A2370/A2450/A4370/A4450/A4550 300 520 M10
A2550 380 670 M10
B4750/B4900 300 670 M10
B411K/B413K 380 710 M10

5
[ Dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-A2004-E1F/A2007-E1F/A2015-E1F/ 3G3RX2-A2004/A2007/A2015/A2022/A2037/A4007/
A2022-E1F/A2037-E1F/A4004-E1F/ A4015/A4022/A4037
A4007-E1F/A4015-E1F/A4022-E1F/
A4037-E1F

6
[ Dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-A2055-E1F/A2075-E1F/A2110-E1F/ 3G3RX2-A2055/A2075/A2110/A4055/A4075/A4110
A4055-E1F/A4075-E1F/A4110-E1F

7
[ Dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-A2150-E1F/A2185-E1F/A2220-E1F/ 3G3RX2-A2150/A2185/A2220/A4150/A4185/A4220
A4150-E1F/A4185-E1F/A4220-E1F

8
[ Dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-A2300-E1F/A4300-E1F 3G3RX2-A2300/A4300

9
[ Dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-A2370-E1F/A2450-E1F/A4370-E1F/ 3G3RX2-A2370/A2450/A4370/A4450/A4550
A4450-E1F/A4550-E1F

10
[ Dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-A2550-E1F 3G3RX2-A2550

11
[ Dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-B4750-E1F/B4900-E1F 3G3RX2-B4750/B4900

12
[ Dimensions ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
3G3RX-B411K-E1F/B413K-E1F 3G3RX2-B411K/B413K

13
[ Characteristics ]
Product discontinuation Recommendable replacement
Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
A2004 A2007 A2015 A2022 A2004 A2007 A2015 A2022
Applicable motor CT 0.4 0.75 1.5 2.2 ND 0.4 0.75 1.5 2.2
(4-pole) capacity VT 0.75 1.5 2.2 3.7 LD 0.75 1.5 2.2 3.7
[kW] VLD 0.75 1.5 2.2 3.7
Rated input 3-phase: 200 V -15% to 240 V 10%, 3-phase: 200 V -15% to 240 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 3.3 5.5 8.3 12 ND 3.8 6.0 9.5 13.1
Rated input
VT 3.9 7.2 10.8 13.9 LD 4.4 7.5 11.2 14.3
current [A]
VLD 5.2 9.5 12.4 18.6
Rated output 3-phase (3-wire) 200 to 240 V 3-phase (3-wire) 200 to 240 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 3.0 5.0 7.5 10.5 ND 3.2 5.0 8.0 11.0
Rated output
VT 3.7 6.3 9.4 12 LD 3.7 6.3 9.4 12.0
current [A]
VLD 4.4 8.0 10.4 15.6
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

Product discontinuation Recommendable replacement


Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
A2037 A2055 A2075 A2110 A2037 A2055 A2075 A2110
Applicable motor CT 3.7 5.5 7.5 11 ND 3.7 5.5 7.5 11
(4-pole) capacity VT 5.5 7.5 11 15 LD 5.5 7.5 11 15
[kW] VLD 5.5 7.5 11 15
Rated input 3-phase: 200 V -15% to 240 V 10%, 3-phase: 200 V -15% to 240 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 18 26 35 51 ND 20.8 29.8 38.1 54.8
Rated input
VT 23 37 48 64 LD 23.3 35.7 47.6 66.7
current [A]
VLD 27.1 39.3 54.8 71.4
Rated output 3-phase (3-wire) 200 to 240V 3-phase (3-wire) 200 to 240 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 16.5 24 32 46 ND 17.5 25.0 32.0 46.0
Rated output
VT 19.6 30 44 58 LD 19.6 30.0 40.0 56.0
current [A]
VLD 22.8 33.0 46.0 60.0
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

14
[ Characteristics ]
Product discontinuation Recommendable replacement
Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
A2150 A2185 A2220 A2300 A2150 A2185 A2220 A2300
Applicable motor CT 15 18.5 22 30 ND 15 18.5 22 30
(4-pole) capacity VT 18.5 22 30 37 LD 18.5 22 30 37
[kW] VLD 18.5 22 30 37
Rated input 3-phase: 200 V -15% to 240 V 10%, 3-phase: 200 V -15% to 240 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 70 84 105 133 ND 76.2 90.5 113.1 145.2
Rated input
VT 80 94 120 150 LD 86.9 101.2 134.5 166.7
current [A]
VLD 95.2 110.7 147.6 182.1
Rated output 3-phase (3-wire) 200 to 240 V 3-phase (3-wire) 200 to 240 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 64 76 95 121 ND 64.0 76.0 95.0 122
Rated output
VT 73 85 113 140 LD 73.0 85.0 113 140
current [A]
VLD 80.0 93.0 124 153
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

Product discontinuation Recommendable replacement


Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
A2370 A2450 A2550 A2370 A2450 A2550
Applicable motor CT 37 45 55 ND 37 45 55
(4-pole) capacity VT 45 55 75 LD 45 55 75
[kW] VLD 45 55 75
Rated input 3-phase: 200 V -15% to 240 V 10%, 3-phase: 200 V -15% to 240 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 160 200 242 ND 173.8 216.7 261.9
Rated input
VT 186 240 280 LD 201.2 250.0 321.4
current [A]
VLD 220.2 272.6 351.2
Rated output 3-phase (3-wire) 200 to 240 V 3-phase (3-wire) 200 to 240 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 145 182 220 ND 146 182 220
Rated output
VT 169 210 270 LD 169 210 270
current [A]
VLD 185 229 295
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

15
[ Characteristics ]
Product discontinuation Recommendable replacement
Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
A4004 A4007 A4015 A4022 - A4007 A4015 A4022
Applicable motor CT 0.4 0.75 1.5 2.2 ND - 0.75 1.5 2.2
(4-pole) capacity VT 0.75 1.5 2.2 3.7 LD - 1.5 2.2 3.7
[kW] VLD - 1.5 2.2 3.7
Rated input 3-phase: 380 V -15% to 480 V 10%, 3-phase: 380 V -15% to 500 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 1.8 2.8 4.2 5.8 ND - 3.0 4.8 6.5
Rated input
VT 2.1 4.3 5.9 8.1 LD - 3.7 5.7 8.0
current [A]
VLD - 4.9 6.4 9.9
Rated output 3-phase (3-wire) 380 to 480 V 3-phase (3-wire) 380 to 500 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 1.5 2.5 3.8 5.3 ND - 2.5 4.0 5.5
Rated output
VT 1.9 3.1 4.8 6.7 LD - 3.1 4.8 6.7
current [A]
VLD - 4.1 5.4 8.3
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

Product discontinuation Recommendable replacement


Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
A4037 A4055 A4075 A4110 A4037 A4055 A4075 A4110
Applicable motor CT 3.7 5.5 7.5 11 ND 3.7 5.5 7.5 11
(4-pole) capacity VT 5.5 7.5 11 15 LD 5.5 7.5 11 15
[kW] VLD 5.5 7.5 11 15
Rated input 3-phase: 380 V -15% to 480 V 10%, 3-phase: 380 V -15% to 500 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 9.8 15 21 28 ND 11.0 17.6 22.6 29.8
Rated input
VT 13.3 20 24 32 LD 13.2 19.0 26.2 34.5
current [A]
VLD 15.0 20.8 29.8 36.9
Rated output 3-phase (3-wire) 380 to 480 V 3-phase (3-wire) 380 to 500 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 9.0 14 19 25 ND 9.2 14.8 19.0 25.0
Rated output
VT 11.1 16 22 29 LD 11.1 16.0 22.0 29.0
current [A]
VLD 12.6 17.5 25.0 31.0
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

16
[ Characteristics ]
Product discontinuation Recommendable replacement
Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
A4150 A4185 A4220 A4300 A4150 A4185 A4220 A4300
Applicable motor CT 15 18.5 22 30 ND 15 18.5 22 30
(4-pole) capacity VT 18.5 22 30 37 LD 18.5 22 30 37
[kW] VLD 18.5 22 30 37
Rated input 3-phase: 380 V -15% to 480 V 10%, 3-phase: 380 V -15% to 500 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 35 42 53 64 ND 38.1 46.4 57.1 72.6
Rated input
VT 41 47 63 77 LD 44.0 51.2 67.9 83.3
current [A]
VLD 47.6 56.0 73.8 91.7
Rated output 3-phase (3-wire) 380 to 480 V 3-phase (3-wire) 380 to 500 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 32 38 48 58 ND 32.0 39.0 48.0 61.0
Rated output
VT 37 43 57 70 LD 37.0 43.0 57.0 70.0
current [A]
VLD 40.0 47.0 62.0 77.0
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

Product discontinuation Recommendable replacement


Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
A4370 A4450 A4550 B4750 A4370 A4450 A4550 B4750
Applicable motor CT 37 45 55 75 ND 37 45 55 75
(4-pole) capacity VT 45 55 75 90 LD 45 55 75 90
[kW] VLD 45 55 75 90
Rated input 3-phase: 380 V -15% to 480 V 10%, 3-phase: 380 V -15% to 500 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 83 100 121 164 ND 89.3 108.3 133.3 178.6
Rated input
VT 94 116 149 176 LD 101.2 125.0 160.7 190.5
current [A]
VLD 110.7 138.1 175.0 209.5
Rated output 3-phase (3-wire) 380 to 480 V 3-phase (3-wire) 380 to 500 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 75 91 112 149 ND 75.0 91.0 112 150
Rated output
VT 85 105 135 160 LD 85.0 105 135 160
current [A]
VLD 93.0 116 147 176
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

17
[ Characteristics ]
Product discontinuation Recommendable replacement
Item Model 3G3RX-[]-E1F Model 3G3RX2-[]
B4900 B411K B413K B4900 B411K B413K
Applicable motor CT 90 110 132 ND 90 110 132
(4-pole) capacity VT 110 132 160 LD 110 132 160
[kW] VLD 110 132 160
Rated input 3-phase: 380 V -15% to 480 V 10%, 3-phase: 380 V -15% to 500 V 10%,
voltage 50/60 Hz ±5% 50/60 Hz ±5%
CT 194 239 286 ND 214.3 258.3 309.5
Rated input
VT 199 253 300 LD 232.1 273.8 345.2
current [A]
VLD 253.6 300.0 376.2
Rated output 3-phase (3-wire) 380 to 480 V 3-phase (3-wire) 380 to 500 V
voltage (depending on receiving voltage) (depending on receiving voltage)
CT 176 217 260 ND 180 217 260
Rated output
VT 195 230 290 LD 195 230 290
current [A]
VLD 213 252 316
CT (Heavy Load) -10 to 50°C ND (Normal Duty) -10 to 50°C
Operating ambient
VT (Light Load) -10 to 40°C LD (Low Duty) -10 to 45°C
temperature
VLD (Very Low Duty) -10 to 40°C
Storage ambient
-20 to 65°C -20 to 65°C
temperature
Operating ambient 20% to 90%RH 20% to 90%RH
humidity (location free of condensation) (location free of condensation)

[ Operation ratings ]
Product discontinuation Recommendable replacement
Model 3G3RX-[]-E1F Model 3G3RX2-[]
Item
A2004 to A2550 B4750 to A2004 to A2550 B4750 to
A4004 to A4550 B413K A4007 to A4550 B413K
CT 0.5 to 15 kHz 0.5 to 10 kHz ND 0.5 to 16.0 kHz 0.5 to 10.0 kHz
Carrier frequency
VT 0.5 to 12 kHz 0.5 to 8 kHz LD 0.5 to 12.0 kHz 0.5 to 8.0 kHz
change range
VLD 0.5 to 10.0 kHz 0.5 to 8.0 kHz
Output frequency
0.1 to 400 Hz 0.00 to 590.00 Hz
range
Digital command ±0.01% and Digital command ±0.01% and
Frequency
analog command ±0.2% (25°C±10°C) analog command ±0.2% (25°C±10°C)
precision
against the maximum frequency against the maximum frequency
Frequency Digital setting: 0.01 Hz Digital setting: 0.01 Hz
resolution Analog setting: maximum frequency/4000 Analog setting: maximum frequency/4000
Acceleration/
0.01 to 3600.0 s 0.00 to 3600.00 s
Deceleration time

[ Operation methods ]
There are some differences of operator, parameters, terminal blocks, default settings and options between
3G3RX-E1F and 3G3RX2.
Please refer to “Replace Guide From 3G3RX to 3G3RX2" (Man. No.: I922-E1), “High-function
General-purpose Inverter RX Series User’s Manual" (Man. No.: I560-E2) and “High-function
General-purpose Inverter RX2 Series User’s Manual" (Man. No.: I620-E1).

Specifications and prices in this product news are as of the issue date and are subject to change without notice.
Only main changes in specifications are described in this document. Please be sure to read the relevant catalogs, datasheets, product
specifications, instructions, and manuals for precautions and necessary information when using products.

18

You might also like