When connecting a Factory Gateway unit, please substitute the words "Factory Gate-
way" for this document's "GP/GLC".
Installation
This CD-ROM includes all the protocol files required by the GP/GLC to communicate
with a Yasukawa Electric Corporation Series PLC. Also, you will need to have one or
more of the following software applications installed. The screen and data transfer files
included in the CD-ROM must be installed in each of those applications. For informa-
tion regarding installing the software, refer to that software's Operation Manual.
Software Applications
• GP-PRO/PBIII for Windows Ver. 2.1 or higher.
• Pro-Server with Pro-Studio for Windows Ver. 3.0 *1
*1 When using the Factory Gateway unit, GP-Web Ver. 1.0 or later or GP-Viewer
Ver. 1.0 or later, be sure to select "Pro-Server with Pro-Studio for Windows"
as the "Destination Folder".
Yaskawa Electric
The following describes the system structure for connecting the GP to Yaskawa PLCs.
The Cable Diagrams mentioned in the following tables are
listed in the section titled "2.4.2 Cable Diagrams".
* 1 Due to the size of its connector case, this cable cannot be used for GP-270,
GP-370, GP-377 and GP-377R Series units
*2 When using an ST401 unit, a 9-pin <-> 25-pin adaptor is required.
GP/GLC
Yaskawa Electric
RS-232C Series
GL120 Corporation
(Cable Diagram 3) *1
JZMSZ-120W0200-03 ST401
GP/GLC
RS-232C Yaskawa Electric Co.
CP-9200 Series
(Cable Memo BUS Cable
CP-9200H
Diagram 1) JZMSZ-W1015-21 *2*3 ST401
* 1 <1:n Connection>
GP
CP-9200SH CP-9200SH
• In this system a total of thirty one (31) CPUs can be connected to one GP.
Be sure to connect only ONE GP unit.
• Even though the CPU settings allow 33 or more units to be designated,
the GP unit's specifications limit the number to 32. Even though a setting
of 33 or more can be entered, the units cannot be used.
• CN1, CN2, CN3 can be connected at the same time.
GP/GLC
*1 RS-232C Series
Micro
(Cable Diagram 5)
ST401
GP/GLC
*1 RS-232C Yaskawa Electric Series
PROGIC-8 *2 *3
(Cable Diagram 4) JEPMC-W5310-03
ST401
GP/GLC
GL120 RS-422 Series
JAMSC-120MON27100
GL130 (Cable Diagram 6)
ST400
* 1 <1:n Connection>
GP
CP-MP920 CP-MP920
• In this system a total of thirty one (31) CPUs can be connected to one GP.
Be sure to connect only ONE GP unit.
• Even though the CPU settings allow 33 or more units to be designated,
the GP unit's specifications limit the number to 32. Even though a setting
of 33 or more can be entered, the units cannot be used.
• PORT1, PORT2, CN1, CN2, CN3 can be connected at the same time.
* 1 <1:n Connection>
GP
-------------------
-
217IF-01 217IF-01
RS-422/485 RS-422/485
Serial Connector Serial Connector
• In this system a total of thirty one (31) CPUs can be connected to one GP.
Be sure to connect only ONE GP unit.
• Even though the CPU settings allow 33 or more units to be designated,
the GP unit's specifications limit the number to 32. Even though a setting
of 33 or more can be entered, the units cannot be used.
• The 217IF-01 RS-232C Serial Connector and the 217IF-01 RS-422/485
Serial Connector can be used at the same time.
The cable diagrams illustrated below and the cable diagrams recommended by
Yaskawa Electric Corporation may differ. Using these cables for your PLC opera-
tions, however, will not cause any problems.
Ground your PLC’s FG terminal according to your country's appli-
cable standard. For details, refer to the corresponding PLC manual.
• Connect the FG line of the Shield cable to either the GP or PLC,
depending on your environment. When using a connector hood
and grounding the FG line, be sure to use an electrical conductor.
The following connection diagrams show examples for connect-
ing a shielded cable to the PLC.
• For the RS-232C connection, use a cable length less than 15m.
• For the RS-422 connection, use a cable length less than 300m.
• If a communications cable is used, it must be connected to the
SG (signal ground).
ST401 Unit
Shield
GP Unit Shield
(25P Male) PLC Unit
7 SG (9P)
9 TERM 7 SG
10 RDA 2 TXD
16 RDB 9-TXD
11 SDA 3 RXD
15 SDB 6-RXD
330Ω 1/4W 18 CSB 1 FG
19 ERB
21 CSA
22 ERA
1 FG
When connecting the #9 and #10 pins in the GP Serial I/F, a termination
Ω is added between RDA and RDB.
resistance of 100Ω
ST400 Unit
ST Unit Shield PLC Unit
(9P Female) (9P)
5 SG 7 SG
1 RDA 2 TXD
2 RDB 9 -TXD
330Ω 1/4W
3 SDA 3 RXD
7 SDB 6-RXD
330Ω 1/4W 6 CSB 1 FG
9 ERB
8 CSA
4 ERA
Connector
Shell
ST401 Unit
Shield
ST401 Unit
Shield
ST Unit Connector Shell 1 FG PLC Unit
(9P Female) 3 SD 2 TXD (9P)
2 RD 3 RXD
7 RS 4 RTS
8 CS 5 CTS
6 DR 6 DSR
5 SG 7 GND
1 CD
4 ER
ST401 Unit
Shield
ST Unit Connector Shell 8 FG PLC Unit
(9P Female) 3 SD 3 TXD (8P)
2 RD 4 RXD
7 RS 6 RTS
8 CS 7 CTS
6 DR 2 DTR
5 SG 5 GND
1 CD
4 ER
Connecting the #9 and #10 pins in the GP Serial I/F adds a termination
Ω between RDA and RDB.
resistance of 100Ω
ST400 Unit
ST Unit
(9P Female) Shield PLC Unit
Connector Shell (9P)
5 SG 7 SGND
1 RDA 2 TXDP
120Ω 1/2W 2 RDB 9 TXDN
3 SDA 3 RXDP
120Ω 1/2W 7 SDB 6 RXDN
6 CSB 1 FG
9 ERB
8 CSA
4 ERA
ST401 Unit
Shield
ST Unit Connector Shell 1 FG PLC Unit
(9P Female) 3 SD 2 SD (9P)
2 RD 3 RD
7 RS 4 RS
8 CS 5 CS
6 DR 6 N.C
5 SG 7 SG
1 CD
4 ER
Shield
ST401 Unit
Shield
GP Unit
(25P Male) Shield
1 FG PLC Unit Shield PLC Unit
7 SG No. 1 No. n
9 TERM SG SG
10 RDA TX+ TX+ 120Ω
16 RDB TX- TX- 1/2W
120Ω 11 SDA RX+ RX+ 120Ω
1/2W 15 SDB RX- RX- 1/2W
18 CSB
19 ERB
Grounding: Your country's
21 CSA
applicable standard.
22 ERA
ST400 Unit
ST Unit
(9P Female) Shield PLC Unit Shield PLC Unit
Connector Shell No. 1 No. n
5 SG SG SG
120Ω 120Ω
1 RDA TX+ TX+
1/2W 1/2W
2 RDB TX- TX-
120Ω 3 SDA RX+ RX+ 120Ω
1/2W 7 SDB RX- RX- 1/2W
6 CSB
9 ERB
8 CSA Grounding: Your country's Grounding: Your country's
4 ERA applicable standard. applicable standard.
ST401 Unit
Shield
Connecting TX- to TXR and RX- to RXR on the PLC side adds a termination
Ω.
resistance of 120Ω
ST400 Unit
GP Unit Shield PLC Unit
(9P Female) MDR 14 Pin Male
5 SG 14 SG
1 RDA 1 TX+
2 RDB 2 TX-
120Ω 3 SDA 3 RX+
1/2W 7 SDB 4 RX-
6 CSB 11 TXR
9 ERB 7 RXR
8 CSA
4 ERA
Connector Shell
ST400 Unit
GP Unit Shield PLC Unit - No. 1 Shield PLC Unit - No. n
(9P Female) MDR 14-Pin Male MDR 14-Pin Male
5 SG 14 SG 14 SG
1 RDA 1 TX+ 1 TX+
2 RDB 2 TX- 2 TX-
120Ω 3 SDA 3 RX+ 3 RX+
1/2W 7 SDB 4 RX- 4 RX-
6 CSB 11 TXR 11 TXR
9 ERB 7 RXR 7 RXR
8 CSA
4 ERA
Connector Shell
Memocon-SC Series
(U84/84J/U84S/GL40S/GL60H/GL70H/GL60S)
Setup System Area here.
Device Bit Address Word Address Particulars
*1
Coil (Output/Internal) 00001 ~ 08192 ---
*1 *2
Input Relay 10001 ~ 14096 ---
*1
Link Coil D0001 ~ D1024 ---
*2
Input Register --- 30001 ~ 30512
H/L
Output/Keep Register --- 40001 ~ 49999
CP-9200/CP-9200H's
Device Word Address Register No. Particulars
Corresponding to Address
Input Register 49744 ~ 49871 IB00000 ~ IB007FF
• If the above devices are used in the Control Pack series, the ad-
dresses converted using the above table should be entered.
• When you wish to use a CP-9200 together with CPU#1's Data Regis-
ter or the System Register, be sure to copy data to the Common Reg-
ister (MW00000 ~ MW07694) first.
Memocon Micro
Setup System Area here.
Device Bit Address Word Address Particulars
*1
Coil (Output/Internal) 00001 ~ 01531 ---
*1
Input Relay 10001 ~ 10511 ---
H/L
Input Register --- 30001 ~ 30047
PROGIC-8 Series
Setup System Area here.
Device Bit Address Word Address Particulars
*1
Output Coil O1 ~ O512 ---
*1 *2
Input Relay l1 ~ I512 ---
*1
Internal Coil N1 ~ N1536 ---
*1
Link Coil D1 ~ D1024 ---
0 0 0
-1 -1 32769
If the DW and the DR are used, be sure to use values in the range from
-9999 to 9999. Data must be displayed in four digits (decimal nota-
tion).
0 0 0
-1 -1 2147483649
MP2300 Series
• Designate the LS area bit at the end of the Word Address, using
from 0 to F.
• Since the Yaskawa Electric MP2000/MP900/CP-9200SH unit’s pro-
tocol can be used for a 1:n connection, it will differ from the
MEMOCON-SC’s protocol and internal method of representing
devices. When you wish to modify the screen data from a
MEMOCON-SC, you will need to reenter device data.
• The hold Register and Input Register device settings must be en-
tered within each block. Any settings that extend into other blocks
are not allowed.
(Example: You cannot enter a 20 word long setting, starting from
GMW1010.)
When you are setting up parts and tags in GP-PRO/PB III, you can desig-
nate PLC’s station numbers as you are inputting addresses. If you do not
designate the station numbers, the number following the one you previ-
ously entered will be automatically selected. (The factory setting is “1”.)
01/1X00201
Address
PLC's Station No. Enter the
PLC's station
number here.
Memocon-SC Series
(GL40S/GL60S/GL60H/GL70H) (GL120CPU Direct Connection)
GP Setup Communication Module Setup
PROGIC-8
GP Setup Port 1/Port 2 Setup
Baud Rate
9600 bps (fixed) ---
(for Port 1 connection)
Baud Rate Baud Rate
19200 bps 19200 bps
(for Port 2 connection) (for Port 2 connection)
Data Length 8 bits ---
Memocon Micro
GP Setup Comm1 Port Setup
Data Length 8 8
Stop Bit 1 1
Station No. 1 ~ 32 1 ~ 32
MP900 Series
GP Setup PLC Setup
Baud rate 19200bps Baud rate 19.2Kbps
Data Length 8 Data Length 8
Stop Bit 1 Stop Bit 1
Parity Bit Even Parity Bit Even
Data Flow Control ER Control Send Mode RTU
Communication Format Serial I/F
RS-232C RS-232C
(RS-232C) (RS-232C)
Communication Format Serial I/F
4 Wire-Type RS-485
(RS-422) (RS-422)
Unit No. 1 Device Address 01
Master Slave Slave
Transmission Protocol MEMOBUS
1 0001 IFON
Write Range HI
2 0012 32787 DW00013
1 0018 IEND
Message Reception Function
(Standard System Function)
1 0019 MSC-RCV
Operating
1 0020 SB000004 EXCUTE BUSY DB000210
FIN FOUT
Normal Complete
1 0022 SB000004 ABORT COMPLETE DB000211 •••/035
FIN FOUT
Error Complete
1 0024 00005 DEV-TYP ERROR DB000212 •••/037
FIN FOUT
Normal Complete
1 0035 DB000211
•••/032
Normal Counter
1 0036[ INC DW00024]
•••/016
Error Complete
1 0037 DB000212
•••/034
1 0038 IFON
Error Counter
2 0039 INC DW00025
•••/017 Result Save
DW00026 •••/053S
2 0040 DW00000
Status Save
DW00027
2 0042 DW00001
Command Receiver ST# Hold
DW00028
2 0044 DW00002
FC Save
DW00029
2 0046 DW00004
Data Address Hold
DW00030
2 0048 DW00005
Data Size Hold
DW00031
2 0050 DW00006
Destination CF# Save
DW00032
2 0052 DW00007
1 0054 IEND
0 0055 DEND
MP2300 Series
GP Setup PLC Setup
Baud Rate (bps) 19200 Baud Rate (bps) 19200
Data Length 8 bits Data Length 8 bits
Stop Bit 1 bit Stop Bit 1 bit
Parity Bit Even Parity Bit Even
Data Flow Control ER Control
RS-232C RS-232C
Communication Format Serial I/F
RS-422 (4-Wire) RS-422/485
Unit No. 1 to 32 Device Address 1 to 32
Transmission Protocol MEMOBUS
Master/Slave Slave
Transmission Mode RTU
Send Delay Not designated
Designated
Auto Receive *1
Not designated
FORi=0 TO 31 BY 1
0 DW0000i DW Register Clear
FEND
00000 DW00008
Coil Offset Setting
00000 DW00009
Relay Offset Setting
00000 Device address-related DW00010 Input Offset Setting
00000 setting values DW00011 Hold Register Offset Setting
00000 DW00012 Write Range LO
65534 DW00013 Write Range HI
00000 DW00024 Normal Pulse Counter Clear
00000 DW00025 Alarm Pulse Counter Clear
00000 DW00014 System Clear
IEND
Instruction Executing
M SG-RCV
Enter the following values SB000004 DB000210
for each module. EXECUTE BUSY
CPU module 8 Stop Normal Complete
217IF 5 SB000004 DB000211
218IF 6 ABORT COMPLETE
Error Complete
DB000212
00008 DEV-TYP ERROR
00001 PRO-TYP
00001 CIR-NO
00001
CH-NO
Enter the circuit number RECV PARAM
used to connect to the GP Normal Complete After the instruction
DA00000
DB000211 message is received, the
acknowledge message
Normal Counter Send Complete turns ON.
[ INC DW00024 ]
Increase Normal Pulse
Error Complete Counter
DB000212
Send Error Completed
IFON
Error Counter Increase Error Pulse
INC DW00025 Counter
DW00000 DW00026
Save processing result
DW0001 DW00027 Save Status
DW0002 DW00028 Save free ST numbers
DW0004 DW00029 Save FC
DW0005 DW00030 Save Data Address
DW0006 DW00031 Save Data Size
DW0007 DW00032 Save destination CP No.
IEND
DEND
A Yasukawa Electric
When the device is setup using the methods below, the Data Communication
Speed declines by the number of times the device is read.
• When consecutive addresses exceed the maximum data number range
• When an address is designated for division
• When device types are different
To speed up data communication, plan the tag layout in screen units, as
consecutive devices. (Includes the Alarm and Trend screens.)
PLC
<Memocon-SC Series (includes Micro)> <PROGIC-8 Series>
Max. No. of Max. No. of
Device Consecutive Device Consecutive
Address Address
Coil Output Coil O
(Output/Internal) 250 Words Input Relay I 250 Words
Input Relay Internal Coil N
Link Coil D 128 Words Link Coil D 128 Words
Input Register Data Register W
Output/Latch Register Input Register D 125 Words
Link Register R 125 Words Link Register R
Constant Register
Extended Register
<MP2300 Series>
Max. No. of Consecutive
Device
Addresses
Coil
Input Relay
125 Words
Special Latch Register
Input Register
Inverter
Max. No. of Consecutive
Device
Addresses
Bit Register
16 Words
Register
Device codes and address codes are used to specify indirect addresses for the
E-tags or K-tags.
The word addresses of data to be displayed are coded and stored in the word
address specified by the E-tags and K-tags. (Code storage is done either by the
PLC, or with T-tag and K-tags)
PLC
<Memocon-SC Series (U84/84J/U84S/GL40S/GL60H/GL70H/GL60S)>
Device code
Device Word Address Address code
(HEX)
Save as word address value
Input Register 30001~ 1240
minus 30001.
Save as word address value
Output/Keep Register 40001~ 0040
minus 40001.
Word Save as word address value
Link Register R0001~ 4840
Device minus 1.
Save as word address value
Constant Register 31001~ 1440
minus 31001.
Extended Register A0000~ 1040 Word Address
<PROGIC-8 Series>
Device code
Device Word Address Address code
(HEX)
Save as word address value
Data Register W1~ 0040
minus 1.
Save as word address value
Word Input Register Z1~ 1240
minus 1.
Device
Save as word address value
Link Register R1~ 4840
minus 1.
LS area LS0000~ 4040 Word Address
<Memocon Micro>
Device code
Device Word Address Address code
(HEX)
Save as word address value
Input Register 30001~ 1240
minus 30001.
Word
Save as word address value
Device Output/Keep Register 40001~ 0040
minus 40001.
LS area LS0000~ 4040 Word Address
<MP900/CP200SH Series>
DEVICE CODE
DEVICE WORD ADDRESS ADDRESS CODE
(HEX)
COIL GMB0000- 0x9000 Word Address value
INPUT RELAY GIB0000 - 0x8000 Word Address value
HOLD REGISTER GMW0000 - 0x0200 Word Address value
HOLD REGISTER GMW1024 - 0x0400 Word Address -1024 value
HOLD REGISTER GMW2048 - 0x0600 Word Address -2048 value
HOLD REGISTER GMW3072 - 0x0800 Word Address -3072 value
Word Addresses
<MP2300 Series>
Device Word Address Device Address Address Code
GMB0000 - 0x9000 Word Address
GMB1024 - 0x9200 Word Address - 1024
Coil
GMB2048 - 0x9400 Word Address - 2048
GMB3072 - 0x9600 Word Address - 3072
GIB0000 - 0x8000 Word Address
GIB0400 - 0x9800 Word Address - 1024
Input Relay
GIB0800 - 0x9A00 Word Address - 2048
GIB0C00 - 0x9C00 Word Address - 3072
GMW00000 - 0x0200 Word Address
GMW01024 - 0x0400 Word Address - 1024
GMW02048 - 0x0600 Word Address - 2048
GMW03072 - 0x0800 Word Address - 3072
GMW04096 - 0x0A00 Word Address - 4096
GMW05120 - 0x0C00 Word Address - 5120
GMW06144 - 0x0E00 Word Address - 6144
GMW07168 - 0x1000 Word Address - 7168
GMW08192 - 0x1200 Word Address - 8192
GMW09216 - 0x1400 Word Address - 9216
GMW10240 - 0x1600 Word Address - 10240
GMW11264 - 0x1800 Word Address - 11264
GMW12288 - 0x1A00 Word Address - 12288
GMW13312 - 0x1C00 Word Address - 13312
Special Latch
GMW14336 - 0x1E00 Word Address - 14336
Register
GMW15360 - 0x2A00 Word Address - 15360
GMW16384 - 0x2C00 Word Address - 16384
GMW17408 - 0x2E00 Word Address - 17408
GMW18432 - 0x3000 Word Address - 18432
GMW19456 - 0x3200 Word Address - 19456
GMW20480 - 0x3400 Word Address - 20480
GMW21504 - 0x3600 Word Address - 21504
GMW22528 - 0x3800 Word Address - 22528
GMW23552 - 0x3A00 Word Address - 23552
GMW24576 - 0x3C00 Word Address - 24576
GMW25600 - 0x3E00 Word Address - 25600
GMW26624 - 0x4200 Word Address - 26624
GMW24648 - 0x4400 Word Address - 27648
GMW28672 - 0x4600 Word Address - 28672
Inverter
Device Word Address Device Code Address Code
BR0000 ~ BR03FF 8200
Bit Device Bit Register BR0400 ~ BR07FF 8400
BR0800 ~ BR0BFF 8600
0000 ~ 03FF 0200 Word Address
Register 0400 ~ 07FF 0400
Word Device
0800 ~ 0BFF 0600
LS Area LS0000 ~ 4000
After Conversion
Special Latch
Coil Input Relay Input Register
Register LS
(GMB) (GIB) (GMW) (GIW)
Coil (GMB)
Before Conversion
: If Conversion Mode is "Word", both word and bit devices will be converted.
If Conversion Mode is "Bit", only bit devices will be converted.