Instruction Manual
Instruction Manual
Instruction Manual
CAUTION
For items described as "Restrictions" or "Usable State" in this manual, the instruction manual
issued by the machine tool builder takes precedence over this manual.
Items not described in this manual must be interpreted as "not possible".
This manual is written on the assumption that all option functions are added. Confirm with the
specifications issued by the machine tool builder before starting use.
Refer to the Instruction Manual issued by each machine tool builder for details on each
machine tool.
Some screens and functions may differ depending on the NC system (or its version), and
some functions may not be possible. Please confirm the specifications before use.
Note that even items ranked as " CAUTION", may lead to major results depending on the
situation. In any case, important information that must always be observed is described.
DANGER
Not applicable in this manual.
WARNING
Not applicable in this manual.
CAUTION
1. Items related to product and manual
For items described as "Restrictions" or "Usable State" in this manual, the instruction
manual issued by the machine tool builder takes precedence over this manual.
Items not described in this manual must be interpreted as "not possible".
This manual is written on the assumption that all option functions are added. Confirm
with the specifications issued by the machine tool builder before starting use.
Refer to the Instruction Manual issued by each machine tool builder for details on
each machine tool.
Some screens and functions may differ depending on the NC system (or its version),
and some functions may not be possible. Please confirm the specifications before
use.
(Continued on next page)
CAUTION
2. Items related to installation and assembly
Ground the signal cables to ensure stable system operation. Also ground the NC unit
main frame, power distribution panel and machine to one point, so they all have the
same potential.
I. SCREEN OPERATIONS
-i-
2.3.7 Executing Restart Search (Restart Type 2) .......................................................................62
2.3.8 Changing the Device..........................................................................................................66
2.3.9 Changing the Directory with the Main Screen....................................................................66
2.3.10 Returning to the Restart Position .....................................................................................67
2.3.11 Executing the MSTB Commands .....................................................................................69
2.4 Program Edit .............................................................................................................................70
2.5 Trace .........................................................................................................................................71
2.5.1 Displaying the Machine Position Trace ..............................................................................74
2.5.2 Canceling the Machine Position Trace...............................................................................75
2.5.3 Displaying the Machine Position of the Tool Center Point Trace .......................................75
2.5.4 Canceling the Machine Position of the Tool Center Point Trace........................................75
2.5.5 Changing the Display Range .............................................................................................76
2.5.6 Changing the Display Mode ...............................................................................................79
2.5.7 Changing the Display Angle...............................................................................................80
2.5.8 Switching the Full-screen Display Mode ............................................................................81
2.5.9 Precautions for Tracing ......................................................................................................81
2.6 Program Check (2D) .................................................................................................................82
2.7 Program Check (3D) [700 series only] ......................................................................................83
2.8 Counter All-axis Display ............................................................................................................84
2.9 Tool Compensation Amount......................................................................................................86
2.10 Workpiece Coordinate System Compensation .......................................................................89
2.11 Counter Set .............................................................................................................................90
2.12 Origin Set, Origin Cancel ........................................................................................................92
2.13 Manual Numerical Value Command .......................................................................................94
2.14 Modal Display..........................................................................................................................96
2.15 Program Tree Display .............................................................................................................99
2.16 Integrated Time Display ........................................................................................................100
2.16.1 Setting the Integrated Time............................................................................................102
2.16.2 Setting the Time Display Selection ................................................................................103
2.17 Common Variables................................................................................................................104
2.17.1 Setting Common Variables ............................................................................................106
2.17.2 Copying/Pasting Common Variables .............................................................................107
2.17.3 Erasing Common Variables ...........................................................................................108
2.18 Local Variables .....................................................................................................................109
2.18.1 Displaying the Arbitrary Local Variables ........................................................................111
2.19 Buffer Correction ...................................................................................................................112
2.20 PLC Switch Function.............................................................................................................115
2.20.1 Turning PLC Switches ON/OFF .....................................................................................116
2.21 Verify Stop.............................................................................................................................117
2.22 Load Meter Display ...............................................................................................................121
2.23 Spindle, Standby Display ......................................................................................................122
2.24 Tool Center Coordinate Display ............................................................................................123
2.25 All Spindles' Rotation Speed Display ....................................................................................125
3. Setup Screen ...............................................................................................................................126
3.1 Screen Configuration ..............................................................................................................126
3.2 Tool Compensation Amount....................................................................................................128
3.2.1 Tool Compensation Amount (M system) ..........................................................................128
3.2.1.1 Setting the Tool Compensation Data ........................................................................132
3.2.1.2 Erasing the Tool Compensation Data .......................................................................134
3.2.1.3 Copying/Pasting the Tool Compensation Data .........................................................135
3.2.2 Tool Compensation Amount (L system)...........................................................................136
3.2.2.1 Wear Data .................................................................................................................136
3.2.2.2 Tool Length Data.......................................................................................................139
3.2.2.3 Tool Nose Data .........................................................................................................141
- ii -
3.2.2.4 Operation Method .....................................................................................................144
3.3 Tool Measurement ..................................................................................................................148
3.3.1 Tool Measurement (M system) ........................................................................................148
3.3.2 Tool Measurement (L system) .........................................................................................154
3.4 Tool Registration .....................................................................................................................165
3.4.1 Registering a Tool in the Magazine Pot ...........................................................................167
3.4.2 Setting the PLC Command ..............................................................................................168
3.4.3 Setting/Erasing the Tool No. of Spindle/Standby Tools ...................................................168
3.4.4 Erasing the Tool Registration Data ..................................................................................169
3.5 Tool Life Management ............................................................................................................170
3.5.1 Displaying the Group List .................................................................................................172
3.5.2 Displaying the Life Management Data in Group Units (M system)...................................176
3.5.3 Displaying the Life Management Data (L system: Tool life management I) .....................184
3.5.4 Displaying the Tool Life Management Data in Group Units (L system: Tool life
Management II) ................................................................................................................187
3.6 Workpiece Coordinate System Offset .....................................................................................193
3.6.1 Setting the Coordinate System Offset..............................................................................195
3.6.2 Erasing the Coordinate System Offset Amount ...............................................................196
3.6.3 Setting the Workpiece Coordinate Origin.........................................................................196
3.6.4 Changing the Coordinate System Display .......................................................................197
3.7 Workpiece Measurement ........................................................................................................198
3.7.1 Workpiece Measurement (M system) ..............................................................................198
3.7.1.1 Carrying Out Surface Measurement..........................................................................202
3.7.1.2 Carrying Out Hole Measurement...............................................................................203
3.7.1.3 Carrying Out Width Measurement.............................................................................205
3.7.1.4 Carrying Out Rotation Measurement.........................................................................207
3.7.1.5 Performing Automatic Recontact When Contacting the Workpiece ..........................211
3.7.2 Workpiece Measurement (L system) ...............................................................................212
3.8 User Parameters .....................................................................................................................219
3.8.1 Selecting the Parameter Number.....................................................................................221
3.8.2 Setting the Parameters ....................................................................................................221
3.8.3 Copying/Pasting Parameters ...........................................................................................222
3.8.4 Parameter Configuration ..................................................................................................224
3.8.5 Echoback .........................................................................................................................225
3.8.6 Ethernet Parameter Password .........................................................................................225
3.8.7 Machine Parameter Password Setting Method................................................................226
3.8.8 Parameter List..................................................................................................................227
3.8.8.1 Process Parameters..................................................................................................227
3.8.8.2 Fixed Cycle ...............................................................................................................232
3.8.8.3 Control Parameters ...................................................................................................233
3.8.8.4 Operation Parameters ...............................................................................................236
3.8.8.5 I/O Parameters ..........................................................................................................238
3.8.8.6 Ethernet Parameters .................................................................................................241
3.8.8.7 Computer Link Parameters .......................................................................................243
3.8.8.8 Subprogram Storage Destination Parameters ..........................................................245
3.8.8.9 Axis Parameters ........................................................................................................246
3.8.8.10 Barrier Data (For L system only) .............................................................................248
3.8.8.11 High Accuracy Parameters......................................................................................249
3.8.8.12 High-accuracy Axis Parameters ..............................................................................254
3.9 MDI Program Editing...............................................................................................................255
3.10 Counter Setting .....................................................................................................................256
3.11 Manual Numerical Value Commands....................................................................................257
3.12 T Code List............................................................................................................................258
3.13 Pallet Program Registration [700 series only] .......................................................................260
- iii -
3.13.1 Standard Pallet Registration ..........................................................................................261
3.13.2 Pallet List Screen ...........................................................................................................263
3.13.3 Pallet Details Screen......................................................................................................265
4. Edit Screen ..................................................................................................................................269
4.1 Screen Configuration ..............................................................................................................269
4.2 Program Editing ......................................................................................................................271
4.2.1 Creating a New Machining Program ................................................................................274
4.2.2 Editing a Machining Program ...........................................................................................275
4.2.3 Editing MDI Program........................................................................................................276
4.2.4 Registering MDI Program in NC Memory.........................................................................276
4.2.5 Deleting a File ..................................................................................................................277
4.2.6 Editing Operations............................................................................................................277
4.2.7 Changing the Display .......................................................................................................278
4.2.8 Displaying an Arbitrary Line .............................................................................................279
4.2.9 Rewriting Data..................................................................................................................280
4.2.10 Inserting Data.................................................................................................................281
4.2.11 Deleting Data .................................................................................................................282
4.2.12 Searching for Character Strings.....................................................................................284
4.2.13 Replacing Character Strings ..........................................................................................286
4.2.14 Copying/Pasting Data ....................................................................................................287
4.2.15 Undoing Program Changes............................................................................................288
4.2.16 Correcting/Displaying Input Mistakes [700 series only]..................................................289
4.2.17 Adding Sequence No. (N No.) Automatically .................................................................295
4.2.18 G Code Guidance ..........................................................................................................298
4.2.19 Playback Editing.............................................................................................................301
4.3 Program Check (2D) ...............................................................................................................306
4.3.1 Checking Continuously ....................................................................................................309
4.3.2 Checking One Block at a Time.........................................................................................311
4.3.3 Canceling the Program Check .........................................................................................312
4.3.4 Drawing during a Program Check ....................................................................................312
4.3.5 Changing the Display Range ...........................................................................................313
4.3.6 Changing the Display Mode .............................................................................................316
4.3.7 Changing the Display Angle.............................................................................................317
4.3.8 Switching to Full-screen Display Mode ............................................................................318
4.3.9 Availability of Check Mode with Other Functions .............................................................319
4.3.10 Handling of Variable Commands, Parameter Input by Program, and Compensation
Data Input by Program .....................................................................................................320
4.3.11 Notes for Program Check (2D).......................................................................................321
4.4 Program Check (3D) [700 series only] ....................................................................................323
4.4.1 Checking Continuously ....................................................................................................326
4.4.2 Checking One Block at a Time.........................................................................................327
4.4.3 Canceling the Program Check .........................................................................................327
4.4.4 Enlarging and Reducing the Workpiece Shape ...............................................................328
4.4.5 Moving the Workpiece Shape ..........................................................................................328
4.4.6 Rotating the Workpiece Shape ........................................................................................328
4.4.7 Performing an Interference Check ...................................................................................329
4.4.8 Switching to Full-screen Display Mode ............................................................................329
4.4.9 Setting the Workpiece Shape...........................................................................................330
4.4.10 Setting the Tool Shape...................................................................................................335
4.4.11 Availability of Check Mode with Other Functions ...........................................................340
4.4.12 Handling of Variable Commands, Parameter Input by Program, and Compensation
Data Input by Program .....................................................................................................340
4.4.13 Notes for Program Check (3D).......................................................................................340
4.5 Program Input/Output..............................................................................................................343
- iv -
4.5.1 Changing the Valid Area ..................................................................................................346
4.5.2 Selecting a Device, Directory, and File ............................................................................347
4.5.3 Transferring a File ............................................................................................................351
4.5.4 Comparing Files (Compare).............................................................................................353
4.5.5 Erasing a File ...................................................................................................................354
4.5.6 Changing a File Name (Rename) ....................................................................................355
4.5.7 Creating a Directory .........................................................................................................356
4.5.8 Merging a File ..................................................................................................................357
4.5.9 Formatting an External Device.........................................................................................358
4.5.10 List of File Names ..........................................................................................................358
4.5.11 Edit Lock B and C ..........................................................................................................359
4.5.12 Program Display Lock C ................................................................................................360
4.5.13 Data Protect Keys ..........................................................................................................361
4.5.14 Sharing Machining Data.................................................................................................362
5. Diagnosis Screens......................................................................................................................365
5.1 System Configuration Screen .................................................................................................365
5.2 Option Display Screen ............................................................................................................368
5.3 I/F Diagnosis Screen...............................................................................................................369
5.3.1 Displaying the PLC Device Data ......................................................................................372
5.3.2 Carrying Out Modal Output ..............................................................................................373
5.3.3 Carrying Out One-shot Output .........................................................................................374
5.4 Drive Monitor Screen ..............................................................................................................375
5.4.1 Servo Axis Unit Display Items ..........................................................................................377
5.4.2 Spindle Unit Display Items ...............................................................................................380
5.4.3 Display Items for the Power Supply Unit..........................................................................389
5.4.4 Display Items for the Auxiliary Axis Unit [700 series only] ...............................................391
5.4.5 Display Items for the Synchronous Error .........................................................................393
5.4.6 Clearing the Alarm History ...............................................................................................394
5.5 NC Memory Diagnosis Screen (NC Memory Diagn Screen) ..................................................395
5.5.1 Writing/Reading the Data Using the NC Data Designation ..............................................397
5.6 Alarm Screen ..........................................................................................................................398
5.6.1 Alarm History....................................................................................................................400
5.7 Self Diagnosis Screen.............................................................................................................402
5.8 Data Sampling Screen ............................................................................................................406
5.8.1 Executing NC Data Sampling...........................................................................................411
5.8.2 Outputting Sampling Data ................................................................................................412
5.9 Anshin-net Screen...................................................................................................................414
5.9.1 Message Display Screen .................................................................................................414
5.9.2 Anshin-net Parameter 1, 2 Screen...................................................................................416
5.9.3 Operation Method ............................................................................................................417
5.9.4 Sharing Machining Data...................................................................................................418
5.10 Machine Tool Builder Network System (MTB net) Screen....................................................419
5.10.1 Message Display Screen ...............................................................................................419
5.10.2 MTB Net Parameter 1, 2 Screen....................................................................................421
5.10.3 Operation Method ..........................................................................................................422
6. Maintenance Screens .................................................................................................................423
6.1 Parameter Screens .................................................................................................................425
6.1.1 Changing the Parameter Display .....................................................................................430
6.1.2 Setting the Parameters ....................................................................................................431
6.1.3 Copying/Pasting Parameters ...........................................................................................433
6.1.4 User Parameters ..............................................................................................................435
6.1.5 Echo Back ........................................................................................................................436
6.2 Input/Output Screen ................................................................................................................437
-v-
6.2.1 Changing the Valid Area ..................................................................................................440
6.2.2 Selecting a Device, Directory and File .............................................................................441
6.2.3 Transferring a File ............................................................................................................448
6.2.4 Comparing Files (Compare).............................................................................................450
6.2.5 Erasing a File ...................................................................................................................451
6.2.6 Changing a File Name (Rename) ....................................................................................451
6.2.7 Creating a Directory .........................................................................................................452
6.2.8 Merging a File ..................................................................................................................453
6.2.9 Formatting an External Device.........................................................................................454
6.2.10 List of File Names ..........................................................................................................454
6.2.11 Edit Lock B and C ..........................................................................................................463
6.2.12 Data Protect Keys ..........................................................................................................464
6.2.13 Sharing Machining Data.................................................................................................466
6.3 All Backup Screen...................................................................................................................469
6.3.1 Performing a Backup Operation.......................................................................................471
6.3.2 Performing a Restore Operation ......................................................................................471
6.4 System Setup Screen .............................................................................................................472
6.4.1 Preparation for Spindle Parameter Setting ......................................................................474
6.4.2 Writing Initial Parameters .................................................................................................475
6.4.3 Writing Sample PLC Ladders...........................................................................................476
6.5 Adjust S-analog Screen ..........................................................................................................477
6.5.1 Adjustment Preparations..................................................................................................479
6.5.2 Performing Automatic Adjustments..................................................................................479
6.5.3 Performing Manual Adjustments ......................................................................................480
6.6 Absolute Position Setting Screen............................................................................................482
6.6.1 Selecting the Axis.............................................................................................................484
6.6.2 Carrying Out Dogless-type Zero Point Initialization .........................................................485
6.6.3 Carrying Out Dog-type Zero Point Initialization................................................................493
6.6.4 Precautions ......................................................................................................................493
6.7 Auxiliary Axis Test Screen [700 series only] ...........................................................................496
6.7.1 Preparation.......................................................................................................................499
6.7.2 Selecting a Device, Directory and File .............................................................................500
6.7.3 Test Operation .................................................................................................................504
6.7.4 Precaution ........................................................................................................................504
6.8 Diagnosis Data Collection Setting Screen ..............................................................................505
6.8.1 Performing a Data Collection Operation ..........................................................................507
6.8.2 Stopping a Data Collection Operation..............................................................................507
6.8.3 Clearing a Collected Data ................................................................................................507
- vi -
2.1 Control Unit Ready......................................................................................................................4
2.2 In Automatic Operation ...............................................................................................................4
2.3 Automatic Operation Start Busy..................................................................................................4
2.4 Automatic Operation Pause Busy ...............................................................................................4
2.5 Return to Reference Position ......................................................................................................4
2.6 Alarm...........................................................................................................................................4
2.7 M00 .............................................................................................................................................4
2.8 M02/M30 .....................................................................................................................................4
3. Reset Switch and Emergency Stop Button ..................................................................................5
3.1 Reset Switch ...............................................................................................................................5
3.2 Emergency Stop Button ..............................................................................................................5
4. Operation Mode...............................................................................................................................6
4.1 Mode Selection Switch................................................................................................................6
4.2 Jog Feed Mode ...........................................................................................................................6
4.3 Rapid Traverse Feed Mode ........................................................................................................7
4.4 Reference Point Return Mode.....................................................................................................8
4.5 Incremental Feed Mode ............................................................................................................10
4.6 Handle Feed Mode....................................................................................................................10
4.7 Memory Mode ...........................................................................................................................11
4.8 MDI Operation Mode.................................................................................................................12
5. Operation Panel Switches in Operation Mode ...........................................................................13
5.1 Rapid Traverse Override...........................................................................................................13
5.2 Cutting Feed Override...............................................................................................................13
5.3 Manual Feedrate .......................................................................................................................13
5.4 Handle/Incremental Feed Magnification....................................................................................14
5.5 Handle Feed Axis Selection ......................................................................................................14
5.6 Manual Pulse Generator ...........................................................................................................14
5.7 Cycle Start and Feed Hold ........................................................................................................15
5.8 Feed Axis Selection ..................................................................................................................15
6. Operation Panel Switch Functions..............................................................................................16
6.1 Chamfering................................................................................................................................16
6.2 Miscellaneous Function Lock ....................................................................................................16
6.3 Single Block ..............................................................................................................................16
6.4 Dry Run .....................................................................................................................................16
6.5 Manual Override........................................................................................................................16
6.6 Override Cancel ........................................................................................................................17
6.7 Optional Stop ............................................................................................................................17
6.8 Optional Block Skip ...................................................................................................................17
6.9 Manual Absolute .......................................................................................................................18
6.10 Error Detect.............................................................................................................................19
6.11 Follow-up Function..................................................................................................................19
6.12 Axis Removal ..........................................................................................................................19
6.13 Manual/Automatic Synchronous Feed ....................................................................................19
6.14 Handle Interruption..................................................................................................................20
6.14.1 Outline..............................................................................................................................20
6.14.2 Interruptible Conditions ....................................................................................................20
6.14.3 Interruption Effective Axis ................................................................................................20
6.14.4 Axis Movement Speed Resulting From Interruption.........................................................21
6.14.5 Path Resulting After Handle Interruption..........................................................................21
6.14.6 Handle Interruption in Tool Radius Compensation ..........................................................23
6.14.7 Interrupt Amount Reset ....................................................................................................25
6.14.8 Operation Procedure........................................................................................................25
- vii -
6.15 Machine Lock ..........................................................................................................................26
6.16 Deceleration Check.................................................................................................................27
6.16.1 Functions..........................................................................................................................27
6.16.2 Deceleration Check Method.............................................................................................28
6.16.3 Deceleration Check When Opposite Direction Movement Is Reversed ...........................30
6.16.4 Parameters.......................................................................................................................31
6.16.5 Precautions ......................................................................................................................32
7. Stored Stroke Limit .......................................................................................................................34
7.1 Stored Stroke Limit I..................................................................................................................36
7.2 Stored Stroke Limit II.................................................................................................................37
7.3 Stored Stroke Limit IB ...............................................................................................................39
7.4 Stored Stroke Limit IC ...............................................................................................................39
7.5 Movable Range during Inclined Axis Control ............................................................................40
7.6 Stored Stroke Limit for Rotation Axis ........................................................................................41
7.7 Precautions ...............................................................................................................................42
III. MAINTENANCE
1. Daily Maintenance and Periodic Inspection and Maintenance ...................................................1
1.1 Maintenance Items......................................................................................................................1
1.1.1 Escutcheon ..........................................................................................................................1
1.1.2 LCD Panel............................................................................................................................2
1.1.3 Compact Flash/IC card ........................................................................................................2
1.2 Replacement Methods [700 series].............................................................................................3
1.2.1 Durable Parts .......................................................................................................................3
1.2.2 Compact Flash .....................................................................................................................7
1.2.3 IC Card.................................................................................................................................8
1.3 Replacement Methods [70 series]...............................................................................................9
1.3.1 Durable Parts .......................................................................................................................9
1.3.2 Compact Flash ...................................................................................................................11
IV. APPENDIXES
Appendix 1. List of Function Codes..................................................................................................1
Appendix 2. Table of Command Value Ranges................................................................................2
Appendix 3. Circular Cutting Radius Error.......................................................................................8
Appendix 4. Registering/Editing the Fixed Cycle Program.............................................................9
4.1 Fixed Cycle Operation Parameters .............................................................................................9
4.2 Transmitting/Erasing the Fixed Cycle Program...........................................................................9
4.3 Standard Fixed Cycle Subprogram (For L system)...................................................................10
4.4 Standard Fixed Cycle Subprogram (For M system)..................................................................20
Appendix 5. RS-232C I/O Device Parameter Setting Examples ....................................................26
Appendix 6. Alarms ..........................................................................................................................27
6.1 List of Alarms ............................................................................................................................27
6.1.1 Operation Alarms ...............................................................................................................27
6.1.2 Stop Codes ........................................................................................................................35
6.1.3 Servo/Spindle Alarms.........................................................................................................39
6.1.4 MCP Alarm.........................................................................................................................48
6.1.5 System Alarms ...................................................................................................................58
- viii -
6.1.6 Absolute Position Detection System Alarms ......................................................................64
6.1.7 Distance-coded Reference Scale Errors............................................................................67
6.1.8 Messages during Emergency Stop ....................................................................................68
6.1.9 Auxiliary Axis Alarms..........................................................................................................70
6.1.10 Computer Link Errors .......................................................................................................77
6.1.11 User PLC Alarms .............................................................................................................78
6.1.12 Network Service Errors ....................................................................................................80
6.2 Operation Messages .................................................................................................................81
6.2.1 Search-related Operation Messages .................................................................................81
6.2.2 Graphic Display-related Operation Messages ...................................................................82
6.2.3 Variable (Common variables, local variables) - related Operation Messages ...................83
6.2.4 PLC Switch-related Operation Messages ..........................................................................83
6.2.5 Compensation-related (Tool compensation, coordinate system offset)
Operation Messages ..........................................................................................................83
6.2.6 Data Input/Output-related Operation Messages ................................................................84
6.2.7 Parameter-related Operation Messages ............................................................................87
6.2.8 Measurement-related (Workpiece, rotation) Operation Messages ....................................88
6.2.9 Tool (Tool registration, tool life) -related Operation Messages ..........................................89
6.2.10 Editing-related Operation Messages................................................................................91
6.2.11 Diagnosis-related Operation Messages ...........................................................................93
6.2.12 Maintenance-related Operation Messages ......................................................................94
6.2.13 Data Sampling-related Operation Messages ...................................................................96
6.2.14 Absolute Position Detection-related Operation Messages...............................................97
6.2.15 System Setup-related Operation Messages ....................................................................97
6.2.16 Automatic Backup-related Operation Messages..............................................................98
6.2.17 Alarm History-related Operation Messages .....................................................................98
6.2.18 Anshin-net-related Operation Messages..........................................................................99
6.2.19 Messages Related to Machine Tool Builder Network System .......................................104
6.2.20 Other Operation Messages ............................................................................................106
6.3 Program Error .........................................................................................................................107
Appendix 7. G Code Guidance Display List .................................................................................126
- ix -
I. SCREEN OPERATIONS
1. Operating the Setting and Display Unit
1.1 Setting Display Unit Appearance
<Example for ABC layout keyboard unit> (5) Data setting keys
(alphabet, numerals, symbols)
(3) Previous screen display key
(1) Function keys (11) Frame keys (Part system changeover)
(4) Menu changeover keys (15) Menu list key (6) Particular keys
I-1
1. Operating the Setting and Display Unit
1.1 Setting Display Unit Appearance
I-2
1. Operating the Setting and Display Unit
1.1 Setting Display Unit Appearance
SFP
F0
(7) Data INSERT (INSERT) This inputs the data insertion mode. When a data
correction Data insert key setting key is pressed, a character is inserted in front
keys of the current cursor position.
The overwrite mode is entered when the DELETE,
C・B CAN, INPUT, cursor or TAB, etc., keys are
pressed, or when the screen is changed.
DELETE (DELETE) This deletes the character just before the cursor
Data delete key position in the data setting area.
C•B This cancels the setting in the data setting area.
CAN / C•B CAN (C・B CAN)
Cancel key
ABC...
(8) Lower case /abc... (LOWER CASE) This changes the input between upper case and lower
input key case alphabetic characters.
(9) SHIFT key SHIFT
(SHIFT) This validates the setting on the lower line of data key.
(10) Cursor keys This moves the cursor up or down one when setting
data in the screen display items.
This moves the cursor one item to the left or right
when selecting data in the screen display items.
at cursor left end: Moves to the right end of
previous line.
at cursor right end: Moves to left end of next line.
This moves the data input cursor one character to the
left or right in the data setting area.
(11) Frame keys This switches the tag.
(12) INPUT key INPUT
(INPUT) This fixes the data in the data setting area, and writes
it to the internal data. The cursor moves to the next
position.
(13) RESET key RESET
(RESET) This resets the NC.
(14) Menu keys This changes the screen and displays the data.
(15) Menu list LIST
(MenuList) This is function that displays each screen's menu
keys configuration as a list. (Refer to "1.7 Menu list")
(16) Operation ALTER (ALTER) This is alternate key (Alt key).
keys This is control key.
CTRL (CTRL)
SP (SP) This is space key.
I-3
1. Operating the Setting and Display Unit
1.2 Screen Configuration
(8)
(9)
(7) (10)
Display items
I-4
1. Operating the Setting and Display Unit
1.2 Screen Configuration
The operation status indicates the operation mode for displayed part system.
The selectable operation mode is following below.
(Note 1) Note the following points when using two or more part systems.
The operation mode displays the operation mode selected for the 1st part system. Thus, when
using two-or-more-part-system machine for which the operation modes are separately selected for
each part system, the operation mode displayed for a part system other than the 1st part system,
and the operation mode on the machine may not match.
The MDI status is displayed when the operation mode is the MDI mode.
This does not appear when other operation modes are selected.
The displayed MDI status is following below.
I-5
1. Operating the Setting and Display Unit
1.2 Screen Configuration
The operation status displays the currently selected NC operation status for each part system. (The status for
up to four part systems is displayed.)
1.2.4 Alarms/Warnings
When an alarm or warning occurs, the alarm No. and alarm message character string are displayed.
(Example)
Searching
I-6
1. Operating the Setting and Display Unit
1.3 Screen Transition Diagram
Search Research Edit Trace Check Cnt exp Offset Coord Cnt set MST
Monitr
Modal Tree Time Com var Loc var P corr PLC SW G92 set Col stp LD MTR
T-ofs T-meas T-reg T-life Coord W-meas User MDI Cnt set MST
T-list Pallet
Setup
Process Fixed Control Operate I/O Ethernet Link Subpro Axis Barrier
param cycle param param param param param stor param data
Hi-prec Hi-prec
param axis
Refer to "3. Setup Screens"
H/W S/W Option I/F dia Drv mon Mem dia Alarm Selfdia NC smp Anshin MTB
Config display message net net
Diagn
Process Control Axis Operate Barrier I/O Ethernet Link Subpro BaseSys
param param param param data param param param stor param
BaseAx BaseCom Axis Zp-rtn Abs pos Servo Spindle Spindle RotAxis
spec param spec param param param spec param param
PLC PLC inc PLC PLC Bit Er Comp Er Comp Macro Posn AUX
timer timer counter constnt select param data list switch param
I-7
1. Operating the Setting and Display Unit
1.4 Screen Selection Procedure
The screen is selected by pressing a function key such as MONITOR or SETUP, or by pressing a menu key
displayed in the screen selection menu.
Operation method (To display "T-ofs" screen from the "Setup screen")
(1) Press the function key SETUP. The previously displayed setup screen will appear.
(2) Press the menu T-ofs key. Tool compensation amount screen appears.
I-8
1. Operating the Setting and Display Unit
1.5 Setting Data
Operation method
(Note 1) The contents in the data setting area are only displayed until the INPUT key is pressed.
These contents are invalidated if the screen is changed. The data is written into the memory when
the INPUT key is pressed.
(Note 2) Special settings may be required depending on the data type. Refer to each item.
(Note 3) The cursor may move to the right of the display item depending on the data type.
(Note 4) If an illegal key is set, an error occurs when INPUT is pressed. Reset the correct data.
The key is input at the position where the cursor is displayed. If a cursor is not displayed, the key input is
invalid.
When a key is input, the data appears at the cursor position, and the cursor moves one character space to
the right.
(2) Press the key. The cursor moves one character space to the right.
123777456
(1) Move the cursor to the position where the The cursor moves in the data setting area.
data is to be inserted. 123456
(2) Press the INSERT key, and then the data The cursor moves one character space to the right.
keys. 123777456
INSERT 7 7 7
(Note) The overwrite mode is entered when the DELETE, C·B CAN keys are pressed, or when the screen is
changed.
I-9
1. Operating the Setting and Display Unit
1.5 Setting Data
(1) Move the cursor to the position where the The cursor moves in the data setting area.
data is to be deleted. 123777456
(2) Press the DELETE key. The character in front of the cursor is deleted, and the
cursor moves.
12377456
(1) Press the C·B key. The cursor moves in the data setting area.
If a cursor is displayed on the screen, data is set in the data setting area and the INPUT key is pressed, the
data appears at the cursor position on the screen. The cursor moves to the next position.
The following keys can be used to move the cursor with the cursor keys.
I - 10
1. Operating the Setting and Display Unit
1.5 Setting Data
In addition to the method of directly inputting numeric data for specific data settings, a method to input the
operation results using four rules operators and function symbols can be used.
Input method
Numeric values, function symbols, operators and parentheses ( ) are combined and set in the data setting
area.
The operation results appear when the INPUT key is pressed. Data for the currently selected setting item will
be set when INPUT key is pressed again. The contents in the data setting area are erased.
Operation examples
(1) Set as shown below, and press the The operation results appear in the data
INPUT key. setting area.
=12∗20 INPUT 240 |
(2) Press the INPUT key again. Data for the selected setting item is set.
The result is displayed on the screen.
The cursor moves to the next position.
I - 11
1. Operating the Setting and Display Unit
1.5 Setting Data
Restrictions
I - 12
1. Operating the Setting and Display Unit
1.6 Operating the Screen
The menu can be used to select screens and to select functions or setting items. Up to ten menus can be
displayed at once.
To select the menu, use the menu key below the menu display.
To change the menu, use the menu changeover key.
(Example) Explanation of menus used for editing the program on the Edit screen (excerpt)
I - 13
1. Operating the Setting and Display Unit
1.7 Menu List
(1)
(2)
(3)
Display items
I - 14
1. Operating the Setting and Display Unit
1.7 Menu List
I - 15
1. Operating the Setting and Display Unit
1.7 Menu List
I - 16
1. Operating the Setting and Display Unit
1.7 Menu List
Operation method
(1) Press the MenuList key. The Menu list window appears showing the selected
screen's menu list at the top.
When the MenuList key is pressed while
editing the file on the Edit screen, a prompt
to confirm whether to save the program
appears before Menu list window opens.
(2) Using the ↑ , ↓ , → , ← and page keys, move The function outline for the selected menu appears.
the cursor to the menu for which the function The function outline does not appear if a menu with no
outline is to be displayed. name is selected.
The cursor does not move to the group
name.
Operation method
(1) Press the MenuList key. The Menu list window appears showing the selected
screen's menu list at the top.
(2) Using the ↑ , ↓ , → , ← and page keys, move The function outline for the selected menu appears.
the cursor to the menu to move to.
(3) Press the INPUT key. The selected menu function can be moved to directly.
The menu is not moved to if a menu with no name is
selected.
The Menu list window closes after moving.
I - 17
1. Operating the Setting and Display Unit
1.7 Menu List
Operation method
(1) Press the MenuList key. The Menu list window appears showing the selected
screen's menu list at the top.
(2) Press the ↓ key four times. The cursor moves down four times, and the screen
scrolls.
(3) Press the ↑ key three times. The cursor moves up three times, and the screen scrolls.
I - 18
1. Operating the Setting and Display Unit
1.7 Menu List
(5) Press the ← key once. (Note 1) The cursor moves to the upper right, and the screen
scrolls.
(7) Press the ↓ key twice. The cursor moves down twice.
(Note 1) The cursor moves in the same way even when the |← key is pressed.
(Note 2) The cursor moves in the same way even when the →| key is pressed.
I - 19
1. Operating the Setting and Display Unit
1.8 Guidance Function
The parameter/operation guidance function displays the details of the parameters or the operation methods
according to the state of the screen currently being displayed.
Screen configuration
The parameter/operation guidance window is displayed with the following type of configuration.
The parameter
detail or operation
method is
displayed.
Operation method
If the ? key is pressed on any screen, the guidance window will open. If a pop-up window other than the
guidance window is open, the guidance window will open over the currently opened pop-up window. In this
case, the menu state does not change. If ? key or CANCEL key is pressed again when the guidance window
is open, the guidance window will close and the screen will return to the previous state in which the ? key was
pressed.
I - 20
1. Operating the Setting and Display Unit
1.8 Guidance Function
(1) Press the Edit menu on operation screen. The edit window is displayed.
(2) Press the ? key. The guidance window is opened, and sub-contents for
edit operation method is displayed.
(3) Move the cursor to the operation method Select the "Program editing - Undoing program
to be displayed by , ,PAGE, PAGE
changes" with the cursor.
keys.
(4) Press the INPUT key. The operation method for "Program editing - Undoing
program changes" is displayed.
(Note 1) If the parameter tag such as machine parameter, fixed cycle, etc. is opened with the key, the
details for the top parameter are displayed.
I - 21
1. Operating the Setting and Display Unit
1.8 Guidance Function
(1) Press the Param menu on maintenance The machining parameter screen is displayed.
screen.
(3) Press the ? key. The guidance window is opened, and the detail of
"#8005 ZONE r" parameter is displayed.
(4) Press the key. The operation method for parameter screen is
displayed.
(Note 1) While guidance window is displayed, the parameter details displayed on each parameter type tab
are recorded. Therefore, when the parameter type is switched with / key, last displayed
parameter details are displayed.
(Note 2) If the parameter No. cannot be gotten (the cursor is non-display, the cursor is put on blank line, the
cursor is put on comment line), the top of parameter guidance for each parameter appears.
I - 22
1. Operating the Setting and Display Unit
1.8 Guidance Function
(1) Press the Search menu on operation The operation search window is displayed.
screen.
(3) Press the key. The contents for operation guidance are displayed.
(4) Move the cursor to the operation method Select the "Restart search - Restart type 2" with the
to be displayed by , ,PAGE, PAGE
cursor.
keys.
I - 23
1. Operating the Setting and Display Unit
1.8 Guidance Function
(5) Press the INPUT key. The operation method for "Restart search" is
displayed.
(Note 1) The operation details of function that cannot be selected because of no option are also displayed on
the contents list.
(Note 2) When the key is pressed during the contents display, the sub-contents for operation search
(operation method (2)) are displayed.
Precaution
(1) If the ? key is pressed when alarm occurs, the alarm guidance window will open.
(2) To display another operation method, select newly an operation method from the contents list. It is not
possible to jump from the parameter, operation details to other details.
(3) When the ? key is pressed while the menu list window is displayed, the guidance window is opened after
the menu list window is closed.
I - 24
1. Operating the Setting and Display Unit
1.8 Guidance Function
The alarm guidance is the function that displays message, details and remedy for the currently occurring
alarms.
This function is an option.
Screen configuration
(1)
(2)
(3)
Display items
I - 25
1. Operating the Setting and Display Unit
1.8 Guidance Function
Operation method
If the ? key is pressed on any screen, the alarm guidance window will open. If a pop-up window other than
the alarm guidance window is open, the alarm guidance window will open over the currently opened pop-up
window. In this case, the menu state does not change. If ? key or CANCEL key is pressed again when the
guidance window is open, the guidance window will close and the screen will return to the previous state in
which the ? key was pressed.
(1) Press the ? key during occurring alarm on The guidance window is opened while "alarm" tag is
operation screen. valid. The alarm details and remedy are displayed for
(Ex.) When "H/W stroke end axis exists" "H/W stroke end axis exists".
and another alarm occur.
(Note 1) The alarm guidance is executed for the alarm that is occurred when the ? key has been pressed.
Therefore, the guidance will be displayed continually even if the alarm is reset while the alarm
guidance is displayed. The alarm guidance is not executed for the alarm that has occurred while the
alarm guidance is displayed.
(Note 2) If the ? key is pressed when an alarm is not occurring, the operation/parameter guidance appears.
In this state, if the "alarm" tag is selected with the right frame key, nothing is displayed in the
message, details and remedy columns. (These columns are blank.)
(Note 3) All the explanations of the alarm having the same error class and No. are displayed in the details
column.
I - 26
1. Operating the Setting and Display Unit
1.8 Guidance Function
(1) Press the key or key when the The alarm guidance with one priority lower than the
alarm guidance is displayed. current alarm guidance is displayed.
If the key or key is pressed when the lowest
priority alarm is displayed, the alarm with the highest
priority is displayed.
(Ex.) When 3 alarms occur.
(1/3) (2/3) (3/3)
(2) Press the key or key when the The alarm guidance with one priority higher than the
alarm guidance is displayed. current alarm guidance is displayed.
If the key or key is pressed when the
highest priority alarm is displayed, the alarm with the
lowest priority is displayed.
(Ex.) When 3 alarms occur.
(1/3) (2/3) (3/3)
Precautions
(1) While the user parameter window on "Setup" or the parameter screen on "Mainte" is displayed, the
parameter guidance display will be prioritized even if an alarm occurs.
(2) When the ? key is pressed while the menu list window is displayed, the guidance window is opened after
the menu list window is closed.
(3) The alarm guidance of stop code and operator message is not displayed.
I - 27
1. Operating the Setting and Display Unit
1.9 Touch Panel Functions [700 series only]
Touch panel screen operation is available with a touch panel display unit.
(1) (2)
(3)
(4)
(5)
(6)
Display items
I - 28
1. Operating the Setting and Display Unit
1.9 Touch Panel Functions [700 series only]
When a place within the data setting area of the screen having a cursor is touched, the cursor moves to the
touched position. Cursor movement by touch panel operation is also possible in the area where the cursor is
moved by , , , , keys. When a window is closed after cursor movement, the cursor
position is returned to the first line. When the cursor is moved or the area is changed by touch panel
operation in the Y/N input wait status (when the [Line clear] menu is selected, etc.) the status will be that
when N is selected (canceled), and then the cursor movement or area change will be carried out.
(2) Select the ALL clear menu. The ALL clear menu is highlighted.
The message "Clear all?(Y/N)" is displayed.
(3) Touch the coordinate value for the The cursor is moved to the touched position.
arbitrary coordinate system offset. The highlight of the ALL clear menu is undone and
"All clear" is canceled.
The message "Clear all?(Y/N)" disappears.
In the screen where active area can be changed, the area touched will become active.
Active area cannot be changed by touch panel operation during mass-editing or file saving for automatic
backup.
I - 29
1. Operating the Setting and Display Unit
1.9 Touch Panel Functions [700 series only]
(1) (2)
Display items
I - 30
1. Operating the Setting and Display Unit
1.9 Touch Panel Functions [700 series only]
(1)
(3)
(2)
(4)
(5)
Display items
I - 31
1. Operating the Setting and Display Unit
1.10 Touch Panel S/W Key
When a touch panel display unit is used, touch panel operation is available.
With the touch panel soft key function, a key input is possible by touching a key on the S/W keyboard which is
displayed on the screen. S/W keyboard is displayed if S/W Key button is touched in each screen. In this
case, screen or menu status will not change. S/W keyboard is always displayed on the front screen. When
the CLOSE key on the S/W keyboard is touched, the S/W keyboard will be closed. S/W keyboard will be
enabled when the parameter "#11010 Software keyboard" is set to "1". When S/W keyboard is disabled,
S/W Key button is not displayed.
I - 32
1. Operating the Setting and Display Unit
1.10 Touch Panel S/W Key
(10)
(11)
(1)
(12)
(2)
(3) (3)
(4) (13)
(5)
Display items
I - 33
1. Operating the Setting and Display Unit
1.10 Touch Panel S/W Key
(1) Touch the S/W Key button. S/W keyboard is displayed on the front screen.
S/W Key button is highlighted.
(2) Touch the CLOSE key, or touch the S/W keyboard will close.
S/W Key button again.
(1) Touch the S/W Key button. S/W keyboard is displayed on the front screen.
S/W Key button is highlighted.
(2) Touch located at the upper right S/W keyboard is displayed on the upper side of the
screen.
corner of the S/W keyboard.
changes to .
(3) Touch located at the upper right S/W keyboard is displayed on the upper side of the
screen.
corner of the S/W keyboard.
changes to .
I - 34
1. Operating the Setting and Display Unit
1.10 Touch Panel S/W Key
If displaying the S/W keyboard while input area is being displayed on a screen, such as in the case where the
operation search window or setup screen is being displayed, the S/W keyboard input area will be valid. At this
time, the key selected on the S/W keyboard is temporarily displayed in the S/W keyboard input area, and then
is input and set in the screen by selecting the INPUT key.
(2) Touch the , , keys to The cursor for tool compensation amount is moved.
move the cursor to an arbitrary position.
(3) Touch the data setting key and enter the "15" is displayed in the S/W keyboard input area.
value.
Example: 15
(4) Touch the INPUT key. "15" is input at the tool compensation amount cursor
position.
If S/W keyboard is displayed while edit window is displayed for program editing or input area is not displayed
on a screen, or when the monitor screen main menu is displayed, S/W keyboard input area will be invalid. At
this time, the key selected on the S/W keyboard is directly input to the screen.
(1) Display the edit window on the monitor S/W keyboard is displayed.
screen and touch the S/W Key button. S/W keyboard input area will be invalid.
(2) Touch the , , keys to The cursor for the edit window is moved.
move the cursor to an arbitrary position.
(3) Touch the data setting key and enter the "G28" is displayed in the edit window.
value.
Example: G28
(4) Touch the INPUT key. "G28" which has been input in the edit window is
confirmed.
I - 35
1. Operating the Setting and Display Unit
1.11 Screen Saver (Backlight OFF) Function
The screen saver function protects the display unit by backlight OFF after the time set in the parameters has
elapsed.
The backlight can also be turned OFF with key operations on the Monitor screen.
The backlight is turned ON by pressing any key, or by touching anywhere on the screen when the display unit
carries a touch-sensitive screen.
The screen saver function has two types: "Automatic change function" that the backlight is turned OFF after a
certain period of time, and "Manual change function" that the backlight is turned OFF by key operations.
If there is no key input, no operation from touch-sensitive screen, or no screen display request signal input
from the machine within the time set in the parameter "#8078 Screen Saver Time", the backlight will be turned
OFF.
If "#8078 Screen Saver Time" is set to "0", the backlight will not be turned OFF.
The backlight can be turned OFF by pressing the SHIFT and C.B CAN keys on the Monitor screen (when a
pop-up screen is not displayed). It is possible to be turned OFF by inputting the keys from the S/W keyboard.
Even if "#8078 Screen Saver Time" is set to "0", the backlight can be turned OFF by pressing the SHIFT and
C.B CAN keys.
(Note 1) Even if the SHIFT and C.B CAN keys are pressed when a screen other than the main menu is
displayed on the Monitor screen (when a pop-up window is displayed), the backlight cannot be
turned OFF.
(Note 2) The backlight cannot be turned OFF by the manual change function on screen other than Monitor
screen.
I - 36
1. Operating the Setting and Display Unit
1.11 Screen Saver (Backlight OFF) Function
1.11.2 Backlight ON
If a key is pressed or the screen display request signal is input while the backlight is OFF, the backlight will be
turned ON.
The backlight is turned ON by touching anywhere on the screen if the display unit carries a touch-sensitive
screen. In that case, even if the screen name tab or the menu is touched, the display is not changed.
Key operation
The correspondence when the key is pressed is as follows during backlight OFF.
(1) Backlight ON + screen transition
(Example) Function key, Part system changeover key, Frame keys, ? key, etc.
Precautions
(1) The backlight will not be turned ON even if the reset key is pressed. However, if the screen display
request signal is input when the reset key is pressed, the backlight will be turned ON. Refer to the
instruction manual issued by each machine tool builder for details. Note that whether the backlight will be
turned ON when any of the machine operation board keys (other than the NC operation board keys) is
pressed will differ according to the machine specifications. Refer to the instruction manual issued by
each machine tool builder for details.
(2) If a key is pressed or the screen display request signal is input while the screen is displayed, counting of
the time to turn the backlight OFF will restart. However, even if SHIFT, ALTER or CTRL key is pressed,
counting of the time to turn the backlight OFF will not restart.
(3) Operation when the or key is pressed will differ according to the machine tool builder. Refer to
the instruction manual issued by each machine tool builder for details.
(4) When the backlight is turned ON, the first character is ignored if the SHIFT + A to W key is input. (Ex.
WHILE -> HILE)
(5) The S/W keyboard is operated regardless of backlight ON/OFF. However, when the backlight is OFF, the
key input is ignored even if the following keys are input from S/W keyboard.
• Data setting keys
• Data correction keys
• SP key
• INPUT key
• Cursor keys
• Page changeover key
I - 37
2. Monitor Screens
2.1 Screen Configuration
2. Monitor Screens
Various information related to operation, such as the axis counter, speed display and MSTB command are
displayed on the Monitor screen. The following operations regarding operation can be executed.
(1) Operation search
(2) Restart search
(3) Editing the searched machining program
(4) Trace (Display of machine movement path)
(5) Check (Display of NC program's tool movement path)
(6) Correction of operating program's buffer
(7) Counter set
(8) Manual numeric command etc.
(6)
(7)
(8)
(1)
(9)
(10)
(11)
(2)
(12)
(3)
(4)
(5)
I - 38
2. Monitor Screens
2.1 Screen Configuration
[For Manual]
(6)
(7)
(8)
(1) (9)
(10)
(11)
(12)
(5)
I - 39
2. Monitor Screens
2.1 Screen Configuration
Display items
I - 40
2. Monitor Screens
2.1 Screen Configuration
(Note) If the program No. (program name) exceeds 12 characters, "*" will appear at the 12th character.
I - 41
2. Monitor Screens
2.1 Screen Configuration
Menus
This enlarges the counter, and displays the counters for all axes. 2.8 Counter All-axis
Display
This displays the tool compensation amount. 2.9 Tool Offset Amount
A value can also be set for the tool compensation amount.
A arbitrary value can be set in the relative position counter. 2.11 Counter Set
I - 42
2. Monitor Screens
2.1 Screen Configuration
This displays the date, time and integrated time, etc., The date, time 2.16 Integrated Time
and integrated time, etc., can also be set. Display
This sets and cancels the origin. 2.12 Origin Set, Origin
Cancel
The spindle load and Z axis load, etc., are displayed in a bar graph. 2.22 Load Meter Display
These displayed contents differ according to the machine tool builder.
The current spindle tool No. and the standby tool No. are displayed. 2.23 Spindle, Standby
These displayed contents differ according to the machine tool builder. Display
This displays the tool center point coordinates, handle interruption 2.24 Tool Center Point
amount (tool axis movement), and tool center point speed. Display
(Note) If the 5-axis related options (tool center point control, tool
length compensation along the tool axis, tool handle feed &
interrupt) are not mounted, these menus are not displayed.
This displays commanded/actual rot speed values of all the spindles. 2.25 All Spindles'
Rotation Speed Display
I - 43
2. Monitor Screens
2.1 Screen Configuration
<Manual>
5-axis related 5-axis related
Layout specifications specifications Remarks
disabled enabled
Left of screen Relative position Tip workpiece This can be changed with "#8905 counter type 5".
position
Right of Machine position Machine position This can be changed with "#8906 counter type 6".
screen
The correspondence between the mode selection switch settings and display contents on the left side of the
screen is as follows.
I - 44
2. Monitor Screens
2.2 Operation Search
On this screen, the program can be called from the program storage site, such as a memory, by designating
the program (program No.) to be automatically run and the program start position (sequence No., block No.).
In 70 series, only the memory, the serial, and the memory card can be used for the input/output device.
(1)
(2)
(3)
(4)
Display items
I - 45
2. Monitor Screens
2.2 Operation Search
Menus
C
Serial
Memory C
card
C
DS
C
FD
List This updates the list contents. (The latest contents of the currently C
update selected device and directory are listed.)
Sort This changes the method that the list is sorted. C 2.2.3 Changing the
change Sorting Method
This changes whether to show or hide the comment field in the list. B 2.2.2 Changing Whether
Comment
When the comment field is hidden, the file name field will be enlarged. to Show or Hide the
nondisp
Comment Field
This closes the pop-up window and quits this function. C
Close
(Note 2) When using serial, the port number set with parameter "#9005 TAPE MODE PORT" is connected,
and search.
I - 46
2. Monitor Screens
2.2 Operation Search
Operation method
(1) Select the part system to run with the The selected part system appears on the upper left of
$<->$ keys. the screen.
(3) Select the device. The selected device name and route directory (HD:/)
(Example) HD appear in the Device name, Directory display field.
(4) Using the ↑, ↓, ½ and ¾ keys, move the The following is displayed.
cursor to the directory containing the file to
be set.
If the list contents differ from the actual device or directory, press the menu List Update .
(5) Press the INPUT key. The active window changes to the directory.
I - 47
2. Monitor Screens
2.2 Operation Search
When designating the sequence number and block number and searching for the program, input the search
conditions in the input area. he program No. is categorized according to the presence of an extension.
(a) Operation search is cancelled if the following operations are carried out on the Edit screen after
operation search. Execute restart search in this case.
• If the searched program is erased.
• If the searched sequence No. is erased.
• If the block corresponding to the searched block No. is erased.
(b) Operation search cannot be executed in another block during MDI operation even if the block is
stopped.
Wait for MDI operation to end or reset the NC before searching.
I - 48
2. Monitor Screens
2.2 Operation Search
The file name field can be extended by changing whether to show or hide the comment field.
Operation method
(1) Press the menu "Comment nondisp". The file name is displayed up to 32 alphanumeric
characters and symbols after the comment field
disappears.
The menu is highlighted.
(2) Press the highlighted "Comment nondisp" The comment field appears, and the file name is
again. displayed up to 15 alphanumeric characters and
symbols.
The menu highlight returns to normal.
"Comment display" is invalidated: The file name is displayed up to 32 alphanumeric characters and
symbols.
(Note 1) The set status is held even if the NC power is turned OFF.
(Note 2) The set status is common for list view of operation screen, restart search screen, etc.
(Note 3) The cursor moves to the head when display/non-display in the comment field is switched.
I - 49
2. Monitor Screens
2.2 Operation Search
Sorting method changes to 1→2→3→4→5→1 • • • • every time the Sort change menu is pressed.
The selected sorting method is also displayed in the list on the ther screens. The method is common for all
the devices, as well. The sorting method will be held even after the power is turned OFF and ON.
Up to 64 files (Including current directory "." and one directory above "..") can be sorted within a directory. If
exceeds 65 files, the Sort change menu is displayed in gray and changing the sorting method is impossible.
In this case, the sorting method is "2. File name character code ascending order".
(Note 1) The character code ascending (descending) order is the method in which file names are compared
one by one using the ASCII code.
Example: If the ascending order is applied, the appropriate order would be 1→A as "1" equals to
"0x31" and "A" equals to "0x41".
(Note 2) When the device is "Memory", display for "current directory" and "one directory above" is not
available.
(Note 3) When comments are the same, sorting is carried out by the file name character code ascending
(descending) order.
(Note 4) "Date/comment" for the devices other than "Memory" are compared using character string only.
Thus, the order will not be one by the actual date.
(Note 5) Sorting method cannot be changed in memory mode.
I - 50
2. Monitor Screens
2.3 Restart Search
If machining is temporarily stopped due to tool breakage, etc., the program restart function searches for the
block of the machining program to be restarted, and restarts machining from that block.
There are two types of restart, type 1 and type 2.
Restart method Details
Restart type 1 After machining is reset due to a tool breakage, etc., machining is restarted from the designated
sequence number and/or block number.
Only the program which had been executed just before can be restarted.
Even after the power is turned ON again, the program can be restarted if the program has been
executed before the power supply is turned OFF.
(Note 1) In case that NC has been reset or the power supply has been turned OFF while fixed
cycle, custom fixed cycle, machine tool builder macro, or macro interruption is
executed, the search with no input to the setting will be performed for each source
program.
(Note 2) When the user macro is executed, the user macro execution position is searched.
Restart type 2 After machining program is stopped due to a holiday, etc., and the power is turned OFF and ON,
machining is restarted from the designated sequence number and/or block number.
Automatic top A top search must be executed from the screen. Then, command a sequence
search OFF No. and block No., and restart a program.
Automatic top A top search may not be executed from the screen. A top search is automatically
search ON executed, so it is not necessary to execute a top search from the screen.
Command a sequence No. and block No., and restart a machining.
An arbitrary program can be restarted by designating the program No.
When a program No. is omitted, the program currently searched is restarted.
The validity of the automatic top search can be changed with control parameter "#8914 Auto Top search".
I - 51
2. Monitor Screens
2.3 Restart Search
Screen transition
<Top search screen> (Note)
[Top search]
[MSTB history]
[MSTB history]
(Note) In the following cases, the screen cannot be switched to top search screen.
• Restart type 1
• The parameter "#8914 Auto Top search" is "1" (automatic top operation)
I - 52
2. Monitor Screens
2.3 Restart Search
(1)
(2)
(3)
(4)
(5)
(6)
Display items
I - 53
2. Monitor Screens
2.3 Restart Search
Menus
I - 54
2. Monitor Screens
2.3 Restart Search
Display items
Same as "2.2 Operation Search".
Menus
I - 55
2. Monitor Screens
2.3 Restart Search
Display items
Same as "2.2 Operation Search".
Menus
C
M-Card
C
DS
C
FD
List This updates the list details. (A list of the latest details of the currently C
update selected device and directory is displayed.)
Sort This updates the list sorting method. C 2.2.3 Changing the
change Sorting Method
This returns the main menu. C
Retn
Comment This changes whether to show or hide the comment field in the list. B
nondisp When the comment field is hidden, the file name field will be enlarged.
I - 56
2. Monitor Screens
2.3 Restart Search
(1)
Display items
Menus
I - 57
2. Monitor Screens
2.3 Restart Search
Restart type 1
When feed hold has been applied and reset because the tool has broken, etc., restart with Restart type 1.
Start
Machining program
Press the feed hold button and retreat to the Feed hold reset
tool change position by manual means or MDI.
Press the RESET key and suspend the present Machining restart
processing.
(Note 1) When single block signal is OFF, the machining is restarted without stopping temporarily after the
axes return to the restart position. (The cycle starts when the automatic return by program restart is
valid.)
I - 58
2. Monitor Screens
2.3 Restart Search
I - 59
2. Monitor Screens
2.3 Restart Search
Restart type 2
If a machining program differing from the machining program to be restarted was run before starting restart
search, restart with restart type 2.
When the coordinate system of the automatic operation last time and the coordinate system of the machining
restart are changed, it is possible to restart.
(Note) The necessary matters for starting the machining program, such as setting the coordinate system,
must be completed before starting restart search.
(Note 1) When single block signal is OFF, the machining is restarted without stopping temporarily after the
axes return to the restart position. (The cycle starts when the automatic return by program restart is
valid.)
(Note 2) Restart Search is not possible for a program with 33 or more file name characters.
(Note 3) When the searched program do not exist, the operation message "Search error" appears.
I - 60
2. Monitor Screens
2.3 Restart Search
When feed hold has been applied and reset because the tool has broken, etc., restart with Restart type 1.
Operation method
(Example) When tool breakage during execution of O1000 N7 occurred, and restarting from the O1000 N6
block
(5) Set the position to restart search in the Delimit the ONB number in the setting area using /.
setting area. <When O No. was attached>
The main or sub program is targeted.
(Ex.) 1000/6/0
<When O No. was not attached>
The program currently searched is targeted.
(Ex.) /6/0
(Note) When the INPUT key is pressed without
entering data in the input area, restart search
will be carried out for the last execution block.
(Type 1 only)
I - 61
2. Monitor Screens
2.3 Restart Search
If a machining program differing from the machining program to be restarted was run with tape, memory or
HD operation before starting restart search, restart the respective machining program with restart type 2.
The restart type 2 operation sequence is the same as restart type 1, but necessary matters for starting the
machining program, such as setting the coordinate system, must be completed before starting restart search.
When the parameter "#8914 Auto Top search" is "0", execute the top search for the machining program.
Operation method (When the parameter "#8914 Auto Top search" is "0")
(Example) When restarting from subprogram O123 N6 B2 called from main program O1000
(5) Press the main menu Restart search . The submenu appears.
The main screen for restart search appears as a
pop-up window.
(7) Press the sub-menu Top search . The window for top search appears as a pop-up
window.
(8) Using the ↑ , ↓ , ½ and ¾ keys, move the Set the cursor to 1000.
cursor to the target machining program.
I - 62
2. Monitor Screens
2.3 Restart Search
(10) Set the position to restart search in the Delimit the ONBP number in the setting area using /.
setting area. <When O No. was attached>
The restart search is executed at designated position
by NBP No. with the set O No. at the head.
(Ex.) 123.PRG/6/2/1
<When O No. was not attached>
The program currently searched is targeted.
(Ex.) /6/2/1
P sets the number of times that the block targeted for the restart search appears.
For example, if a block in a subprogram is searched, and the subprogram is called out several times,
the block to be searched is also executed several times. Thus, which execution block to be searched
must be set. (If "0" is set, it is handled in the same manner as "1".)
To search the first execution block, or to search for a block executed only once, this item does not
need to be set.
I - 63
2. Monitor Screens
2.3 Restart Search
Operation method (When the parameter "#8914 Auto Top search" is "1")
(Example) When restarting from subprogram O123 N6 B2 called from main program O1000
(5) Press the main menu Restart search . The submenu appears.
The main screen for restart search appears as a
pop-up window.
(7) Press the sub-menu File set . The window for file set appears as a pop-up window.
(8) Using the ↑ , ↓ , ½ and ¾ keys, move the Set the cursor to 1000.
cursor to the target machining program.
(9) Press the INPUT key. The screen for restart search appears as a pop-up
window.
I - 64
2. Monitor Screens
2.3 Restart Search
(10) Set the position to restart search in the Delimit the ONBP number in the setting area using /.
setting area. <When O No. was attached>
The restart search is executed at designated position
by NBP No. with the set O No. at the head.
(Ex.) 123.PRG/6/2/1
<When O No. was not attached>
The program currently searched is targeted.
(Ex.) /6/2/1
I - 65
2. Monitor Screens
2.3 Restart Search
Operation method
(1) Press the submenu File set . The window for file setting appears as a pop-up
window.
(2) Select the device, and press the menu The selected device name and root directory (HD:/)
key. appear in the Device name and Directory display field.
(Example) HD
(Note) In 70 series, only the memory and the memory card can be used for the input/output device.
Operation method
(1) Press the submenu File set . The window for file setting appears as a pop-up
window.
(2) Using the ↑ , ↓ , ½ and ¾ keys, move the The following is displayed.
cursor to the directory to be moved.
If the list contents differ from the actual device or directory, press the menu List Update .
(3) Press the INPUT key. The directory changes, and the contents of the
designated directory appear in the list.
The moved directory appears in the directory display
field.
(5) After changing the directory, press the The restart search main window opens as a pop-up
Retn or CANCEL key. window.
I - 66
2. Monitor Screens
2.3 Restart Search
(3) Move the axis in the restart return The restart position and "RP" appear sequentially from the
direction. axes that have been returned. The Restart remaining
distance is "0".
(Note 1) When the restart switch is ON, move the axis in the same direction as the restart direction. If moved
in the reverse direction, the operation error "M01 R-pnt direction illegal" occurs. If the tool needs to
be retracted once, such as if the tool is interfering with the workpiece, turn the restart switch OFF
and retract the axis manually.
(Note 2) After restart position return is completed, the axis cannot be moved if the restart switch is ON. If the
axis is moved, the operation error "M01 restart switch ON" occurs.
(Note 3) If even one axis has not completed return to the restart position at cycle start, the error "T0112
Restart pos. return incomplete" occurs. Note that if the axis has been returned to the restart position
once and is not at the restart position during cycle start, the alarm does not occur.
(Note 4) If the axis to be returned to the restart position is a machine lock axis, the operation error "M01
program restart machine lock" occurs. Release the machine lock before returning to the restart
position.
(Note 5) If the restart switch is turned to ON after the axis is returned to the restart position with the restart
switch OFF, "PR" may not be displayed. Return to the restart position after the restart switch is
turned ON.
(Note 6) After restart search had been completed, if the movement command is issued by MDI before
automatic restart position return has been started, the program error (P48) occurs. Perform the
operation again after reset.
I - 67
2. Monitor Screens
2.3 Restart Search
(Note 7) After restart search had been completed, if the T command different from the program is issued by
MDI before the searched program has been started, the program error (P48) may occur. Perform
the operation again after reset. T commands which result in errors are shown below. (Only L
system)
(1) When "#1100 Tmove" = "0"
T command that selects a tool with different tool length/wear amount than the tool selected by
the program
(2) When "#1100 Tmove" = "1"
A program error will not occur by T command.
(3) When "#1100 Tmove" = "2"
T command that selects a tool with different wear amount than the tool selected by the program
(Note 8) After restart search had been completed, if the handle interruption is performed before the searched
program has been started, always the same operation as manual absolute ON is executed
regardless of "Manual absolute" signal.
If the parameter "#1302 AutoRP" is set to "1", each axis returns to the restart position with dry run at cycle
start. Machining restarts after returning. The order that the axes return follows parameter "#2082 a_rstax".
(Note 1) Manually move the axis to a position where the tool does not interfere with the workpiece before
starting the cycle.
(Note 2) Even if the parameter "#1302 AutoRP" is set to 1, the axes can be returned manually to the restart
position by turning the restart switch ON. In this case, move the axes in the order of manual restart
position return → automatic restart position return. After completing automatic restart position return,
if the operation is stopped temporarily and the restart switch is turned ON, the operation error "M01
restart switch ON" occurs.
(Note 3) Once the axis has been manually returned to the restart position, if it is moved from the restart
position, it will not return to the restart position even if automatic restart position return is executed.
(Note 4) The axis for which parameter "#2082 a_rstax" is set to 0 does not return to the restart position. Note
that if 0 is set for all axes, all axes simultaneously return to the restart position. Designate the axes
in part system units. If the axis for which parameter "#2082 a_rstax" is set to 0 has not completed
manual restart position return when automatic restart position return is started, the error "T0112
Restart pos. return incomplete" occurs.
(Note 5) After automatic restart position return had been started, if the automatic start is executed during
MDI mode before not all axes have yet to complete automatic restart position return, the error
"T0112 Restart pos. return incomplete" occurs.
(Note 6) After restart search had been completed, if the movement command is issued by MDI before
automatic restart position return has been started, the program error (P48) occurs. Perform the
operation again after reset.
(Note 7) After restart search had been completed, if the T command different from the program is issued by
MDI before the searched program has been started, the program error (P48) may occur. Perform
the operation again after reset. T commands which result in errors are shown below. (Only L
system)
(1) When "#1100 Tmove" = "0"
T command that selects a tool with different tool length/wear amount than the tool selected by
the program
(2) When "#1100 Tmove" = "1"
A program error will not occur by T command.
(3) When "#1100 Tmove" = "2"
T command that selects a tool with different wear amount than the tool selected by the program
(Note 8) After restart search had been completed, if the handle interruption is performed before the searched
program has been started, always the same operation as manual absolute ON is executed
regardless of "Manual absolute" signal. When manual interruption is executed to the automatic
restart position return completed axis, the axis never returns the automatic restart position again.
(Note 9) When an axis moved to return is operated manually, the axis cannot return to correct position.
I - 68
2. Monitor Screens
2.3 Restart Search
Operation method
(1) Press the submenu MSTB history . The pop-up window changes to the MSTB history
window.
The MSTB commands used for machining program
are listed.
(3) Press the INPUT key. The designated command is executed. A value, which
has been commanded once, is displayed in gray. The
cursor will move to the next item.
(5) When completed with all settings, press The MSTB history pop-up window closes and the
the Close or MSTB history menu. restart search main window appears as a pop-up
window.
I - 69
2. Monitor Screens
2.4 Program Edit
The machining programs are edited. When the main menu Edit is pressed, the operation searched
program (MDI program for MDI mode) appears.
If no program has been searched or tape operation has been executed, the edit window will not open.
When the program is edited, the key input data is directly written into the program display area. All data is
overwritten from the cursor position. "Editing" appears on the right side of the file name display when the input
starts. When the INPUT key is pressed, the program is saved in the NC memory and the "Editing"
message disappears.
Refer to "4.2 Program edit" for details.
I - 70
2. Monitor Screens
2.5 Trace
2.5 Trace
This function illustrates the actual machine's movement path or tool center point movement path, and draws
the actual machine movement.
This allows the machine operation to be monitored during machining.
The programs that can be traced are operation searched machining programs (MDI program for MDI mode).
If no program has been operation searched, the trace window will not open.
Using All display menu, normal display and whole display modes can be switched.
(Note 1) The trace function is an additional specification. The graphic trace option is required.
(Note 2) The tool center point trace function is an additional specifications. The 5-axis related options (tool
center point control, tool length compensation along the tool axis, tool handle feed & interrupt) are
required.
(1)
(2)
(3)
(4)
(5)
< Drawing area: 2-plane > < Input area displayed >
(6)
I - 71
2. Monitor Screens
2.5 Trace
(1)
(5)
(3)
(7)
(2)
(4)
Display items
I - 72
2. Monitor Screens
2.5 Trace
Menus
This changes the graphic drawing display range. C 2.5.5 Changing the
When this menu is pressed, the menu changes to the display range Display Range
Display change menu.
range
When the display range is changed, the graphic data displayed on the
screen is erased.
This changes the drawing plane. C 2.5.6 Changing the
When this menu is pressed, the menu changes to the display mode Display Mode
change menu.
Display
mode There are three types of graphic display modes: 1-plane, 2-plane and
3D.
When the drawing plane is changed, the graphic data displayed on
the screen is erased.
All This switches the normal display mode and the full-screen display B 2.5.8 Switching the
display mode. Full-screen Display
Mode
This displays the machining program being executed on the graphic B
Program drawing area.
display This menu can be selected only when the full-screen display mode is
applied.
This sets the viewpoint angle for the 3D display mode. C 2.5.7 Changing the
When the viewpoint angle is changed, the graphic data displayed on Display Angle
Rotate
the screen is erased.
Note that this menu can be used only in the 3D display mode.
The display range (scale and display position) is automatically set C
from the machine movable area. The machine movable area is set
Std with the parameters "#2013 OT-" and "2014 OT+" (software limit).
range
When the display range is changed, the graphic data displayed on the
screen is erased.
This displays the selected counter. For each trace mode, the counter C
type can be set separately. And the setting is held after the power is
turned OFF and ON. However, if the [Trace ON] or [Tip traceON]
menu is not highlighted, this is displayed in gray and cannot be
selected.
The following counters can be selected.
• Relat posn (Related position counter)
• Work co posn (Workpiece coordinate position counter)
Counter • Machine posn (Machine position counter)
type
• Remain command (Remain command counter)
• Next command (Next command counter)
• Program posn (Program position counter)
• Tip wk posn (Tool tip workpiece position counter)
• Tip machine (Machine position of tool center point counter)
• Pulse (Tool axis movement counter)
(Note) During the trace mode, "Tip wk posn", "Tip machine" and
"Pulse" are cannot selected.
This closes the pop-up window and quits this function. C
Close
I - 73
2. Monitor Screens
2.5 Trace
Operation method
(1) Press the main menu Trace ON . • The Trace ON menu is highlighted.
If Tip TraceON is highlighted, unhighlight it.
• The machine position appears in the drawing area
as a tool mark.
• The counter selected by Counter type menu is
displayed at the counter.
• The message "Tracing" appears.
After this, the machine position path is drawn with
graphics in the trace mode.
(Note) If graphic check (2D) is executed, the "Trace
ON" status is cancelled.
I - 74
2. Monitor Screens
2.5 Trace
Operation method
(2) Press the main menu Trace ON . • The Trace ON menu is unhighlighted.
• The tool mark in the drawing area is erased.
• The message "Tracing" is erased.
(Note) Even if the menu is unhighlighted, the
displayed counter type does not change.
2.5.3 Displaying the Machine Position of the Tool Center Point Trace
Operation method
(1) Press the main menu Tip TraceON . • The Tip TraceON menu is highlighted.
If Trace ON is highlighted, unhighlight it.
• The tool center point appears in the drawing area as
a tool mark.
• The counter selected by Counter type menu is
displayed at the counter.
• The message "Tracing Tip Position" appears.
2.5.4 Canceling the Machine Position of the Tool Center Point Trace
Operation method
(2) Press the main menu Tip TraceON . • The Tip TraceON menu is unhighlighted.
• The tool mark in the drawing area is erased.
• The message "Tracing Tip Position" is erased.
(Note) Even if the menu is unhighlighted, the
displayed counter type does not change.
I - 75
2. Monitor Screens
2.5 Trace
(1) Press the Display range key. A white frame indicating the display range appears on
the screen.
The display range input mode is activated, and the
following menu appears.
(2) Press the menu Zoom in or Zoom out. The size of the white frame changes according to the
key operations.
To enlarge the figure:
Press the menu Zoom In or the -
key.
To reduce the figure:
Press the menu Zoom out or the +
key.
I - 76
2. Monitor Screens
2.5 Trace
(1) Press the Display range key. A white frame indicating the display range appears on
the screen.
The display range input mode is activated, and the
following menu appears.
(2) Press the Up , Down , Left , Right The cursor () indicating the center of the display and
menu or cursor movement keys ↑ , ↓ , the frame line move up, down, left and right according
←, → . to the key operations.
(3) Press the INPUT key. The display position changes so that the cursor
position () is the center of the area.
By changing the display position, the graphic data
displayed on the screen is erased, however, the scale
value is not changed.
(Note 1) When changing the display range in the 2-plane display mode such as "XY/XZ", the display range
(scale and display position) for the upper and lower areas changes in the same manner.
The operation method is the same as the 1-plane display mode.
The white-framed display range in the upper and lower areas simultaneously move to the left/right
when the Left , Right keys are pressed.
The white-framed display range of either upper or lower areas moves up and down when the
Up , Down keys are pressed.
Which frame to be moved up/down can be changed with the page key.
I - 77
2. Monitor Screens
2.5 Trace
(1) Press the Display range key. A white frame indicating the display range appears on
the screen.
The display range input mode is activated, and the
following menu appears.
(2) Press the Centering key. The display position is changed so that the current
machine position appears in the center of the drawing
area.
When display position is changed, the graphic data
displayed on the screen is erased.
(Note 1) In the 2-plane display mode such as "XY/XZ", centering is applied for the upper and lower areas.
The operation method is the same as the 1-plane display mode.
I - 78
2. Monitor Screens
2.5 Trace
(Note 1) When display mode is changed, the graphic data displayed up to that point are erased.
(Note 2) The set display mode is held even after the power is turned OFF and ON.
(Note 3) The display mode can be set independently for the trace function and program check function.
These settings are not sequenced.
(Note 4) The menu axis names XYZ correspond to the base axis IJK. X = base axis I, Y = base axis J, and Z
= base axis K.
(1) Press the menu Display mode . The menus for the selectable display modes appear.
The input area appears.
(2) Select the mode to display and press the The display mode and drawing area appear as a
menu. 2-plane image.
(Example) XY/XZ
I - 79
2. Monitor Screens
2.5 Trace
(1) Press the menu Display mode . The menus for the selectable display modes appear.
The input area appears.
(2) Set the axis name, and press the INPUT XYC appears as the axis name in the display mode.
key. The X axis, Y axis and C axis are the three axes for
drawing.
XYC INPUT
The display mode includes the 1-plane, 2-plane and 3D display modes. The display mode currently
selected is shown with an image. The selected axis names are displayed in the image.
Display example
<1-plane> (XY) <2-plane> (XY/XZ) <3D> (XYZ)
(Note 1) When the display angle is changed, the graphics displayed up to that point are erased.
(Note 2) The set display angle is held even if the power is turned ON and OFF.
(Note 3) The display angle can be set independently for the trace function and program check function.
These settings are not sequenced.
Operation method
(1) Press the menu key Rotate . The rotation mode is activated, and the following menu
appears.
(2) Use the Up , Down , Left , Right The cube displayed at the lower right of the screen
menu to adjust the display angle. rotates according to the key operations.
(Note 1) The set display angle is held even after the power is turned OFF and ON.
I - 80
2. Monitor Screens
2.5 Trace
Press the All display menu key to display the trace window on the whole screen. (full-screen display
mode).
Press this menu again to return the normal display.
All display
menu : ON
All display
menu : OFF
(Note 1) The selected display mode is maintained even after rebooting the machine.
(Note 2) The full-screen display mode is applied to the trace function and program check (2D/3D solid)
function commonly.
(Note 3) The full-screen display mode is applied commonly to all part systems.
Displaying a program
When pressing the Program display menu key, the contents of the machining program currently being
checked is displayed on the drawing area.
When pressing the Program display again, the displayed program is erased.
Note that this menu can be used only when the full-screen display mode is selected.
(Note 1) The selected display mode is maintained even after rebooting the machine.
(Note 2) The program display mode is applied to the trace function and program check (2D) function
commonly.
(Note 3) The Program display menu key cannot be selected while the normal display mode is selected.
Program display mode is valid only when the full-screen display mode is selected.
(Note 4) The program display mode is applied commonly to all part systems.
Refer to section "4.3.11 Precautions for Program Check Function (2D)" for other precautions.
I - 81
2. Monitor Screens
2.6 Program Check (2D)
Program check (2D) is a function that draws the machining program movement path without executing
automatic operation. The machining program can be checked with graphic data drawn at a high speed.
Using All display menu, normal display and full-screen display modes can be switched.
The programs that can be checked are operation searched machining programs (MDI program for MDI
mode).
If no machining program has been operation searched, the program check window will not be opened.
Refer to "4.3 Program Check (2D)" for details.
(Note) The program check (2D) function is an additional specification. The graphic check option is required.
I - 82
2. Monitor Screens
2.7 Program Check (3D) [700 series only]
Program check (3D) is a function that draws the workpiece shape and tool movement in the cutting process
of the machining program as a solid image without executing automatic operation. The machining program
can be checked with graphic data drawn at a high speed.
Using All display menu, normal display and full-screen display modes can be switched.
The operation searched machining program (MDI program for MDI mode) can be checked.
The Program Check window will not open if no machining program has been searched.
The workpiece shape and tool shape used with this function can be set on the Edit screen.
Refer to section "4.4 Program Check (3D)" for details.
(Note) The program check (3D) function is an additional specification. The graphic check and 3D solid
graphic check options are required.
I - 83
2. Monitor Screens
2.8 Counter All-axis Display
I - 84
2. Monitor Screens
2.8 Counter All-axis Display
Menus
Manual This displays the amount moved with the manual mode while the B
int amt manual absolute switch was OFF.
This displays the value obtained by subtracting the tool compensation B
Program
posn amount compensated for that axis from the position actually being
executed for each axis.
This closes the pop-up window and quits this function. C
Close
This displays the position of the tool end from the workpiece B
Tip wk
posn coordinate reference point in the selected workpiece coordinate
system.
Tip This displays the position of the tool end from the machine coordinate B
machine system reference point in the machine coordinate system.
This displays the amount moved in the selected axis direction using B
the manual pulse generator in the hypothetical machine coordinate
system.
Pulse
Basically this is updated only when manual ABS is OFF. If "#7905
NO_ABS" is set to "1", this will be updated regardless of the manual
ABS ON/OFF.
(Note 1) The type of counter displayed first when the pop-up display appears is the relative position. If the
5-axis related option is ON, the counter will be the "Tip wk posn".
The counter which appears next is the type selected previously.
(Note 2) The menus Tip wk posn, Tip machine and Tip axis movement appear when the 5-axis related
option is ON.
I - 85
2. Monitor Screens
2.9 Tool Compensation Amount
I - 86
2. Monitor Screens
2.9 Tool Compensation Amount
I - 87
2. Monitor Screens
2.9 Tool Compensation Amount
! CAUTION
! If the tool offset amount or workpiece coordinate system offset amount is changed during
automatic operation (including during single block stop), the changes will be valid from the
command in the next block or after several subsequent blocks.
I - 88
2. Monitor Screens
2.10 Workpiece Coordinate System Compensation
The coordinate system offset controlled by the NC can be set and displayed.
48 or 96 sets of coordinate system offset sets can be added according to the option.
Refer to "3.6 Workpiece Coordinate System Offset" for details.
! CAUTION
! If the tool offset amount or workpiece coordinate system offset amount is changed during automatic
operation (including during single block stop), the changes will be valid from the command in the
next block or after several subsequent blocks.
I - 89
2. Monitor Screens
2.11 Counter Set
An arbitrary value can be set in the relative position counter which opens as a pop-up window.
Menus
I - 90
2. Monitor Screens
2.11 Counter Set
Operation method
(1) Press the main menu Counter set . The relative position counter opens as a pop-up
window.
The cursor appears at the 1st axis of the relative
position counter.
Instead of the operation above, the axis The relative position counter opens as a pop-up
name address key can be pressed to set window.
the counter. The cursor appears at the designated axis (Z axis).
(Example) Z
(3) Input a numeric value. The set value "100.000" appears at the cursor
(Example) 100.000 INPUT position. The cursor moves to the next axis.
(4) Repeat step (3) for each axis. The pop-up window closes when the counter has been
set for the last axis.
For axes that are not to be operated, press
the ↓ key and move the cursor.
I - 91
2. Monitor Screens
2.12 Origin Set, Origin Cancel
Menus
I - 92
2. Monitor Screens
2.12 Origin Set, Origin Cancel
(1) Press the main menu G92 set . The relative position counter opens as a pop-up
window.
The menu Origin set is highlighted.
The cursor appears at the 1st axis of the relative
position counter.
(3) Input 0, and then press the INPUT key. "0.000" appears at the cursor position.
The cursor moves to the next axis.
If the INPUT key is pressed without
inputting a value, zero (0) will be set.
(Origin zero)
(4) Repeat step (3) for each axis. The pop-up window closes when the origin has been
set for the last axis.
For axes that are not to be operated, press
the ↓ key and move the cursor.
(1) Press the main menu G92 set , and then The relative position counter opens as a pop-up
press the menu Origin cancel . window.
The menu Origin cancel is highlighted.
The cursor appears at the 1st axis of the relative
position counter.
(2) Press the INPUT key. The same value as the machine position appears at
the cursor position.
The cursor moves to the next axis.
(3) Repeat step (2) for each axis. The pop-up window closes when the origin has been
canceled for the last axis.
For axes that are not to be operated, press
the ↓ key and move the cursor.
I - 93
2. Monitor Screens
2.13 Manual Numerical Value Command
The spindle function (S), miscellaneous function (M), tool function (T) and 2nd miscellaneous function (B)
commands can be executed.
The manual numerical value command can be executed by inputting an address such as S, M, T or B, as
well.
Menus
I - 94
2. Monitor Screens
2.13 Manual Numerical Value Command
(1) Press the main menu MST . The S, M, T, B display opens as a pop-up window.
S 100
M 50
T 4
B 1000
(2) The manual numerical value command The S, M, T, B display opens as a pop-up window.
can also be issued by using the address The cursor appears at T.
keys instead of the operation above.
(Example) T S 100
M 50
T 4
B 1000
(Note) The cursor moves to the first line when the part system is changed while displaying the manual
numeric command window.
The manual numerical value command mode is canceled by carrying out one of the following operations
before pressing the INPUT key.
• Press the menu Close
• Press the key
• Change the screen
For each S, M, T and G command, the data type to output to user PLC is designated by parameters
"#12006 Mbin M binary", "#12008 Sbin S binary", "#12010 Tbin T binary" and "#12012 Bbin B binary".
The output data type and the manual numerical value command setting/output range are shown below.
(Note 1) Even if the parameter (#12008 Sbin S binary) is set to "0" (BCD), the signed binary output is
applied to S. BCD output is not applied.
(Note 2) If a negative value is set when the data type is "BCD type" or "No-signed binary type", a value
converted into positive value is output to user PLC.
(Note 3) Add a "-" sign before the value to set a negative value. The display will be a positive value.
(Note 4) A value larger than "#3001 slimt1" to "#3004 slimt4" or "#3005 smax1" to "#3008 smax4"
cannot be output for S.
I - 95
2. Monitor Screens
2.14 Modal Display
(1)
(3)
(2)
(4)
(6)
(5)
(7)
(8)
(9)
(10) (11)
Display items
This displays each modal state.
Display item Details
(1) G00…G94 Status of currently executed G command modal
:
G69…G42.1
(2) G50:P=0.000000 Scaling magnification
(3) G54.1:P0 Extended workpiece coordinate system
(4) G69:R=0.000 Coordinate rotation angle (Displays within a ±360° range)
(5) G05:P0 High-speed machining mode
Q1 High-speed high-accuracy control 1
Q2 Spline interpolation
P10000 High-speed high-accuracy control 2 (SSS control OFF)
P1 High-speed machining mode I
P2 High-speed machining mode II
P3 High-speed machining mode III
SSS SSS valid
(6) G40: Tool radius compensation modal
D0 Compensation No.
= 100.000000: Shape compensation amount in respect to tool radius
10.000000 Tool radius wear amount
(7) G49: Tool length compensation modal
Z Compensation axis name
H0 Compensation No.
= 0.000000: Compensation amount
0.000000 Tool length wear amount
(8) G07.1:OFF Cylindrical interpolation modal
(9) G08: High-accuracy control mode
P0 High-accuracy control mode OFF
P1 High-accuracy control mode ON
(10) FA F modal value of currently executed program command
FM Manual federate
(11) Program command modal value of each currently executed command
S1 to S4 S command
M1 to M4 M command
T T command
B 2nd miscellaneous function (B) command
I - 96
2. Monitor Screens
2.14 Modal Display
<L system>
(1)
(9)
(2)
(3) (10)
(4)
(5)
(11)
(6)
(12)
(7)
(8)
(13)
Display items
This displays each modal state.
Display item Details
(1) G01…G94 Status of currently executed G command modal
:
G69…G42.1
(2) G54.1:P10 Extended workpiece coordinate system
(3) TX : -12.345 The total value of the first axis' tool length and wear compensation amount for the tool
being used
(4) TZ : 12.345 The total value of the second axis' tool length and wear compensation amount for the
tool being used
(5) TY : 10.000 The total value of the additional axis' tool length and wear compensation amount for
the tool being used
(6) TG : 123 Tool length compensation No.
(7) TW : 123 Wear compensation No.
(8) V 12345678 Modal value for constant surface speed spindle rotation speed (V1 to V4)
(9) FA 24000.00 F modal value of currently executed program command
(10) FM 1200.00 Manual federate
(11) FS 0.0000 Program command synchronous feedrate modal value
(12) FE 0.0000 Thread lead command synchronous feedrate modal value
(13) Program command modal value of each currently executed command
S1 to S4 S command
M1 to M4 M command
T1 to T2 T command
B 2nd miscellaneous function (B) command
I - 97
2. Monitor Screens
2.14 Modal Display
Menus
I - 98
2. Monitor Screens
2.15 Program Tree Display
This displays the main program, subprogram, MDI interrupt and user macro call nesting structure.
Display items
Menus
I - 99
2. Monitor Screens
2.16 Intagrated Time Display
The integrated time (date, time, power ON time, automatic operation time, automatic start time, external
integrated time 1, external integrated time 2, cycle time) controlled by the NC can be set and displayed.
Note that the cycle time cannot be set. (Cycle time is display only.)
The integrated times displayed in cycle time display area on "Auto/MDI" tag can be set.
Display items
(Note) When the #3 Power ON to #8 Cycle time displays reach the maximum value (9999:59:59), the count
stops, and the maximum value remains displayed.
I - 100
2. Monitor Screens
2.16 Intagrated Time Display
Menus
Time The time that is displayed in upper line on cycle time display C 2.16.2 Setting the Time
select1 area is selected. Display Selection
Time The time that is displayed in bottom line on cycle time display C
select2 area is selected.
This closes the pop-up window and quits this function C
Close
I - 101
2. Monitor Screens
2.16 Intagrated Time Display
Operation method
(1) Press the menu Time setting . The time setting mode is entered.
The cursor appears at the "#1 Date" position in the
integrated time display.
(2) Input today's date. "2003.08.19" appears at "#1 Date", and the cursor
(Example) 2003/8/19 INPUT moves to "#2 Time".
(3) Set the data for each item, and press the When "#7 External integrated time 2" has been set,
INPUT key. the cursor disappears, and the time setting menu
highlight is turned OFF.
If the item does not need to be set, press
the ↓ key and move the cursor.
Note that #8 Cycle time cannot be set, so
the cursor will not move.
(Note 2) If the Time setting menu or key is pressed again during the time setting mode, the time
setting mode will be canceled.
Setting range
I - 102
2. Monitor Screens
2.16 Intagrated Time Display
Operation method
(1) Press the menu "Time select1" The time selection mode is activated, and the following
menu appears.
Power Auto Auto Ext Ext Cycle
Date Time
ON oper strt time1 time2 time
(2) Press the time type for the mode to The automatic operation time is displayed in upper line
display. on cycle time display area. The menu display returns
(Example) "Auto oper" to integrated time sub-menu.
(3) Press the menu "Time select2" The time selection mode is activated, and the following
menu appears.
Power Auto Auto Ext Ext Cycle
Date Time
ON oper strt time1 time2 time
(4) Press the time type for the mode to The automatic operation time is displayed in bottom
display. line on cycle time display area. The menu display
(Example) "Power ON" returns to integrated time sub-menu.
(Note 1) The displayed time is held even after the power is turned OFF and ON.
I - 103
2. Monitor Screens
2.17 Common Variables
The details of the common variables can be set and displayed on this screen.
If there is a common variable command (Note) in the machining program, the variable value (variable name)
set when the block is executed is displayed.
The number of common variable sets differs according to the specifications.
(Note) The variable names can be set for common variables #500 to #519.
(1)
(2)
(3)
Display items
I - 104
2. Monitor Screens
2.17 Common Variables
Menus
This clears the contents of the variable No. at the cursor position or A 2.17.3 Erasing Common
Variabl continuous variable Nos. Variables
clear (Note) The contents are not cleared to "0". The state with no data is
entered.
This clears the variable No. at the cursor position or the continuous A
Name
clear variable number's variable name (Variable name: variable No. 500 to
519).
This closes the pop-up window and quits this function. C
Close
I - 105
2. Monitor Screens
2.17 Common Variables
(2) Designate the variable No. The common variable for the set No. appears at the
102 INPUT head.
(2) Input a value. The value obtained by adding the input value to the
1.234 +INPUT original value appears.
(Example) If the original value is 135.000, 136.234
appears. (135.000 + 1.234 = 136.234)
Operation method (Setting "COUNTER" as the variable name for variable No. 509)
(1) Select common variable 509 with the The cursor appears at the cursor 509 variable position.
same procedure as steps (1) and (2)
above.
(2) Press the key. The cursor moves to the 509 variable name.
(Note) The variable name can be set only for variable Nos. 500 to 519.
I - 106
2. Monitor Screens
2.17 Common Variables
Operation method
(1) Select the variable to be copied. The cursor moves to the selected variable.
(2) Press the menu Copy . One line of the copied variable is highlighted.
(3) Select the variable to be pasted, and press The copied variable is pasted, and the highlight returns
the menu Paste . to normal.
The copied variable is held until a variable is newly
copied.
I - 107
2. Monitor Screens
2.17 Common Variables
Operation method (Erasing the variable value for variable number 102 to 104)
(2) Input the No. (range) of the variable to be A message confirming the erasing appears.
erased. The background color of the erase range (variable
102/104 INPUT value) changes to light blue.
Operation method (Erasing the variable name for variable No. 509)
(2) Select the variable , and press the INPUT A message confirming the erasing appears.
key The background color of the erase range (variable
name) changes to light blue.
509 INPUT
(3) Press the Y key. The variable name for 509 only is erased.
The variable value is not erased.
The variable at the cursor position will become the target of the erasing if the INPUT key is pressed without
designating a variable No.
I - 108
2. Monitor Screens
2.18 Local Variables
(1)
(2)
(3)
(4)
Display items
I - 109
2. Monitor Screens
2.18 Local Variables
Menus
Display This lowers the local variable display level one by one. If this menu is C 2.18.1 Displaying the
level- pressed when the display level is 0, the level changes to display level Arbitrary Local Variables
4.
This increases the local variable display level one by one. If this menu C
Display
level+ is pressed when the display level is 4, the level changes to display
level 0.
This closes the pop-up window and quits this function. C
Close
Relation of user macro subprogram call execution level and display level
Main (level 0) O1 (level 1) O10 (level 2) O100 (level 3) O1000 (level 4)
#1=0.1
#2=0.2 : : :
#3=0.3 G65 P10A10.B20. G65 P100A100. G65 P1000A1000.
: C30.; B200.; B2000.; :
G65 P1A1.B2.C3.; : : :
: M02; M99; M99; M99;
M02;
Local variable Local variable Local variable Local variable Local variable
Precautions
The local variables are not erased when reset or when the power is turned OFF. They are erased at macro
call.
I - 110
2. Monitor Screens
2.18 Local Variables
When the menu Display level + is pressed again, the display level changes in the order of 2 → 3 → 4
→ 0 → 1 → 2 → … and so forth.
When the menu Display level - is pressed again, the display level changes in the order of 0 → 4 → 3
→ 2 → 1 → 0 … and so forth.
The displayed local variable No. changes when the page changeover keys (previous page , next page
) are pressed.
#1
:
#12
#13
:
#24
#25
:
#33
I - 111
2. Monitor Screens
2.19 Buffer Correction
During automatic operation (Memory, HD, FD, DS, memory card) or MDI operation, a block stop can be
applied, and the next command can be corrected or changed.
When a program error occurs, the block in which the error occurred can be corrected without resetting the NC,
and operation can be continued.
In 70 series, only the memory and the memory card can be used for the input/output device.
Memory
HD
Memory
card Preread Execution
DS Machine
block block NC operation control
FD
MDI
Buffer correction
(1) The next command can be corrected in the following two cases.
• When single block stop is applied, and there is a command block to be corrected in the next
command.
• When there is an error (program error) in the next command and automatic operation is stopped.
(2) Not only the displayed buffer data but also the contents in the device are corrected with the buffer
corrections. (The corrected data is reflected.)
(3) Several blocks following the next command can be corrected simultaneously.
Menus
I - 112
2. Monitor Screens
2.19 Buffer Correction
Operation method
During a single block stop or when a program error stop occurs, the buffer can be corrected with the following
operations, and operation can be continued.
The normally executed program appears in the buffer correction area.
(1) Press the main menu Prg correct . The buffer correction mode is entered.
(3) Press the INPUT key. The buffer correction mode ends, and the corrected
data is written into program.
If a program error has occurred, the error display is
erased.
(4) Confirm that the corrected data is correct, The program execution resumes from the currently
and then restart. stopped position.
I - 113
2. Monitor Screens
2.19 Buffer Correction
Precautions
(1) Buffer correction mode will not be applied in the following cases.
(a) Machining program for buffer corrections is in edit lock or program display lock state.
(b) Data protection key 3 is enabled.
(c) Machining program for the device in write-protection state
(d) Machining program in read-only state
I - 114
2. Monitor Screens
2.20 PLC Switch Function
The various control signals for NC operation can be turned ON and OFF.
Refer to the instruction manual issued by the machine tool builder for details.
(1)
(2)
Display items
Menus
I - 115
2. Monitor Screens
2.20 PLC Switch Function
(1) Press the menu Setting valid . The menu Setting valid will be highlighted.
A message confirming the start of PLC switch setting
will appear.
(2) Press "Y" or INPUT The PLC switch setting mode will be entered.
The cursor will appear at the PLC switch No. position.
The menu keys ON and OFF will appear normally.
(3) Press the cursor keys ↑ and ↓ to The #6 number is highlighted.
move the cursor to "#6".
(4) Press the menu key ON . The "#6 Program restart" switch turns ON, and a *
mark appears.
To turn OFF, press the menu key OFF.
a * mark appears.
(Note 1) If the Setting valid menu or key is pressed again during the PLC switch setting mode, the
PLC switch setting mode will be canceled.
(Note 2) The PLC switch setting mode is canceled when the PLC switch's pop-up window is closed.
(Note 3) The cursor will not appear in modes other than the PLC switch setting mode.
I - 116
2. Monitor Screens
2.21 Verify Stop
The machining program operation can be block stopped at a registered verify stop position. The registered
verify stop position can be canceled.
In 70 series, only the memory, the serial, and the memory card can be used for the input/output device.
(Note) Verify stop is an additional specification. The verify stop option is required.
(1)
(2)
(3)
I - 117
2. Monitor Screens
2.21 Verify Stop
Display items
C
Serial
Memory C
card
C
DS
C
FD
List This updates the list contents. (The latest contents of the currently C
update selected device and directory are listed.)
Sort This changes the method of sorting the list. C 2.2.3 Changing the
change Sorting Method
Stop This opens the verify stop position display window as a pop-up C "Canceling the verify
posn window. stop"
This changes whether to show or hide the list comment field. B 2.2.2 Changing Whether
Comment
The file name field is increased when the comment field is hidden. to Show or Hide the
nondisp
Comment Field
This closes the pop-up window and quits this function. C
Close
I - 118
2. Monitor Screens
2.21 Verify Stop
(1) Select the part system for executing verify The currently selected part system is displayed at the
stop with the $<->$ key. upper left of the screen.
(2) Press the main menu Verify stop . The verify stop submenu appears.
The list appears as a pop-up window.
(3) Select the device. The device name and root directory (HD:/) selected in
(Example) HD the device name and directory display fields are
displayed.
If the list contents differ from the actual device or directory, press the menu List update .
(5) Press the INPUT key. The cursor moves within the directory.
(6) Input the program No., sequence No. and The verify stop position is displayed, and the program
block No. using / as a delimiter. No. ("MDI" for MDI mode), sequence No., block No.
(Example) 1001/1/2 INPUT and [Verifying] appear.
(7) Start the automatic operation. When the verify stop is completed, a message
indicating the end appears.
The stop position displayed on the screen is cleared,
and the [Verifying] display is erased.
I - 119
2. Monitor Screens
2.21 Verify Stop
(1) Carry out the operations in "Operation The verify stop position appears.
method (Registering verify stop)".
If the verify stop position is not displayed,
press the menu Stop position .
(2) Press the menu Stop cancel . The stop position displayed on the screen is cleared,
and the [Verifying] display is erased.
Precautions
(1) When registering the stop position (O, N, B values), confirm that the block exists in the searched
program. Verify stop will not be executed if the corresponding block is not found at the registered stop
position.
(2) Always set one of the O, N or B numbers. If nothing is set, a setting error will occur.
(3) If the O No. is not set, the O No. used during operation search will be used.
(4) If the N and B numbers are not set, the block will be searched using the O No.
(5) If there are several sequences and blocks with the same number in one program, verify stop will be
executed after executing the first block that matches in the execution order.
(6) The settings are canceled when verify stop is executed.
(7) The settings are canceled when reset is executed.
(8) If only the program number is set, verify stop will take place at the head of the program only when there
is a program number at the first line.
(9) Verify stop / Verify stop cancel cannot be performed for blocks being executed or blocks already read
into the preread buffer.
(10) Verify stop is not performed in the tapping mode.
(11) Verify stop is possible in a subprogram, but is not possible in a machine tool builder macro program.
(12) If verify stop is set for a fixed cycle block, verify stop will be executed after the positioning block is
completed.
(13) Verify stop is possible even when editing is locked.
(14) Verify stop is executed after executing the block set for the verify stop position. If the verify stop position
is set in a program call (M98) block, verify stop will be executed before the subprogram is called.
(15) If the set block is set to be skipped, verify stop will not be executed.
(16) The verify stop position can be registered for each part system.
(17) The stop position cannot be registered during verification.
(18) Registration of verify stop position is not possible for a program with 33 or more file name characters.
(19) In the case where the device is HD, memory card, DS, or FD at the time of verify stop position
registration, inputting "0//" will be resulted in a setting error.
I - 120
2. Monitor Screens
2.22 Load Meter Display
(1)
Display items
Menus
I - 121
2. Monitor Screens
2.23 Spindle, Standby Display
The current spindle tool No. and the standby tool No. are displayed.
(1)
(2)
(3)
Display items
Menus
I - 122
2. Monitor Screens
2.24 Tool Center Coordinate Display
The tool center coordinates, handle interrupt amount (tool axis movement) and tool center point speed are
displayed during the tool center point control function, tool length compensation along tool axis function, and
tool handle feed & interrupt function (handle feed along the tool axis, tool handle interrupt, tool diameter
direction handle feed, nose center rotation handle feed).
This function is an additional specification. The 5-axis related options (tool center point control, tool length
compensation along the tool axis, tool handle feed & interrupt) are required.
(1) (4)
(5)
(2)
(3)
(6)
Display items
I - 123
2. Monitor Screens
2.24 Tool Center Coordinate Display
Menus
I - 124
2. Monitor Screens
2.25 All Spindles' Rotation Speed Display
The current spindle tool No. and the standby tool No. are displayed.
This function only displays the value. It is not possible to operate here.
(2)
(1)
Display items
Menus
I - 125
3. Setup Screen
3.1 Screen Configuration
3. Setup Screen
The setup screen is used to make tool and workpiece related settings, set user parameters, edit the MDI, set
the counter, and perform manual numerical value commands.
(1)
(2)
(3)
Display items
I - 126
3. Setup Screen
3.1 Screen Configuration
Menus
This sets an arbitrary value for the relative position counter. 3.10 Counter Setting
This performs the manual numerical value commands. 3.11 Manual Numerical
Value Commands
This searches T code among the designated program (including the 3.12 T Code List
subprograms) and lists in order that it was found. This menu is displayed only
when the T code list option is valid.
This registers machining programs to the pallet of automatic pallet changer 3.13 Pallet Program
(hereinafter APC). This menu displays if the option is enabled. Registration
This menu is only for 700 series.
I - 127
3. Setup Screen
3.2 Tool Compensation Amount
(1)
I - 128
3. Setup Screen
3.2 Tool Compensation Amount
(1)
! CAUTION
If the tool compensation amount or workpiece coordinate system offset amount is changed during
automatic operation (including during single block stop), the changes will be valid from the
command in the next block or after several subsequent blocks.
I - 129
3. Setup Screen
3.2 Tool Compensation Amount
Display items
(Note 1) The display range is when the minimum command unit is 1µm ("#1003 iunit"
= B, "#1041 I_inch" = 0).
Furthermore, the display and setting ranges are as follows based on the "#1003 iunit"
and "#1041 I_inch" setting combination.
Setting/display range
#1003 #1041
iunit I_inch Type I
Type II Length wear Type II Length dimension
Radius wear Radius dimension
0 -99.999 to 99.999 -999.999 to 999.999
B
1 - 9.9999 to 9.9999 -99.9999 to 99.9999
0 -99.9999 to 99.9999 -999.9999 to 999.9999
C
1 - 9.99999 to 9.99999 -99.99999 to 99.99999
0 -99.99999 to 99.99999 -999.99999 to 999.99999
D
1 - 9.999999 to 9.999999 -99.999999 to 99.999999
0 -99.999999 to 99.999999 -999.999999 to 999.999999
E
1 - 9.9999999 to 9.9999999 -99.9999999 to 99.9999999
I - 130
3. Setup Screen
3.2 Tool Compensation Amount
Menus
Set the compensation number and press INPUT to put that A 3.2.1.1 Setting the Tool
Offset Compensation Data
No. number to the top and display the tool compensation data.
The cursor moves to the contents of that first line.
Line This copies the contents of the tool compensation data in the selected C 3.2.1.3 Copying/Pasting
copy line (one line). the Tool Compensation
Data
The contents (one line) of the copied tool compensation data are C
written to the line where the cursor is.
If changes are made to the data in that line after Line copy is
Line
paste selected from the menu, the data prior to the changes is written when
pasting.
The data in the copied line can be pasted as many times as is
required until new data is copied.
This erases the compensation data in the selected line (multiple lines A 3.2.1.2 Erasing the Tool
can be erased). Compensation Data
Selection method: Select the first and the last compensation number
Line to be erased.
clear [Ex.] 1/E: Set all compensation data to "0".
If the INPUT key is pressed without selecting a line, the
compensation data in the line where the cursor is currently positioned
is erased.
This undoes the last changes to the tool compensation data. C
Undo (This menu is valid for the "Data Input", "Paste Line" and "Undo"
operations.)
I - 131
3. Setup Screen
3.2 Tool Compensation Amount
Operation method (Setting "37.000" in the length wear data of compensation No. (102))
(2) Designate the Compensation No. The set number appears at the top of the area, and the
102 INPUT cursor moves.
(4) Input the length wear value. The set value displays.
37.000 INPUT
Settings can be made by pressing the
=INPUT key instead of the INPUT
key.
Old New
I - 132
3. Setup Screen
3.2 Tool Compensation Amount
Operation method ("-3.000" is calculated and set in the length wear data for compensation number
(102).)
(2) Enter a value. The input value is added to the original value and
-3.000 +INPUT displays.
[Ex.] 37.000 displays if the original value is 40.000.
(40.000 – 3.000 = 37.000)
Old New
I - 133
3. Setup Screen
3.2 Tool Compensation Amount
Operation method (Erasing one line of tool compensation data at the cursor position)
(1) Move the cursor to the line to The cursor appears at the data item of the selected
be erased with the ↑ , ↓ , and compensation No.
keys.
(2) Press the Line clear and INPUT The menu keys are highlighted and a message
menu. displays confirming whether it is okay to erase.
The background color of the data to be erased
displays in light blue.
(3) Press the Y or INPUT key. The selected line of data (one line amount) is cleared
to zero.
To cancel the erasing, press a key other The data erased to zero displays at the top of the
than Y or INPUT . compensation data.
Operation method (Erasing the compensation data from compensation number 122 to 125.)
(2) Input the compensation number of the A message box displays to confirm whether it is okay
data range to be erased. to erase the data.
122/125 INPUT The background color of the data to be erased
displays in light blue.
(3) Press the Y or INPUT key. The compensation data for the selected compensation
number is erased, and the menu highlight returns to
Press a key other than Y or INPUT normal.
in order not to erase the data. The data cleared to zero displays at the top of the
compensation data.
(Note) If the INPUT key is pressed without selecting an compensation number, the line where the cursor
is located is erased.
I - 134
3. Setup Screen
3.2 Tool Compensation Amount
(2) Press the Line copy menu. The background color of the copied data changes to
light blue.
(4) Press the Line paste menu. The copied compensation data is written in the line
where the cursor is.
The background color returns to normal.
The copied compensation data is held until another
line is copied.
(Note 1) If the compensation data for the copied line is changed after the menu Line copy is pressed, the
data prior to the change is written when pasted.
I - 135
3. Setup Screen
3.2 Tool Compensation Amount
(1)
! CAUTION
If the tool compensation amount or workpiece coordinate system offset amount is changed during
automatic operation (including during single block stop), the changes will be valid from the
command in the next block or after several subsequent blocks.
I - 136
3. Setup Screen
3.2 Tool Compensation Amount
Display items
(Note 1) The display range is when the minimum command unit is 1µm ("#1003 iunit"
= B, "#1041 I_inch" = 0).
(Note 2) Set whether to set the additional axis tool nose wear compensation amount
for 3rd or 4th axis at parameter "#1520 Tchg34".
(Note 3) Displays only for the number of valid axes if only 1st axis or 2nd axis are
valid.
(Note 4) Depending on the setting of parameter #8010(Max. value), the
setting/display range may be different from the above.
(Note 5) Depending on the setting of parameter #8011(Max. additional value), the
setting/display range may be different from the above.
Furthermore, the display and setting ranges are as follows based on the "#1003 iunit"
and "#1041 I_inch" setting combination.
(Type I, Type II, Type III wear and tool length data)
#1003 #1041
Setting/display range
iunit I_inch
0 -99.999 to 99.999
B
1 - 9.9999 to 9.9999
0 -99.9999 to 99.9999
C
1 - 9.99999 to 9.99999
0 -99.99999 to 99.99999
D
1 - 9.999999 to 9.999999
0 -99.999999 to 99.999999
E
1 - 9.9999999 to 9.9999999
X axis offset
X axis tool length offset +X axis wear offset
Z axis offset
Z axis tool length offset +Z axis wear offset
Tool nose
I - 137
3. Setup Screen
3.2 Tool Compensation Amount
Menus
I - 138
3. Setup Screen
3.2 Tool Compensation Amount
(1)
! CAUTION
If the tool compensation amount or workpiece coordinate system offset amount is changed during
automatic operation (including during single block stop), the changes will be valid from the
command in the next block or after several subsequent blocks.
Display items
(Note 1) The display range is when the minimum command unit is 1µm ("#1003 iunit"
= B, "#1041 I_inch" = 0).
(Note 2) Set whether to set the additional axis tool nose wear compensation amount
for 3rd or 4th axis at parameter "#1520 Tchg34".
(Note 3) Displays only for the number of valid axes if only 1st axis or 2nd axis are
valid.
I - 139
3. Setup Screen
3.2 Tool Compensation Amount
Generally, the center of the tool rest or the tip of the base tool is used as the programmed base position.
(1) The programmed base position is the center of the tool rest:
Basic position
(basic point)
(2) The programmed base position is the tip of the base tool:
Basic tool
Menus
I - 140
3. Setup Screen
3.2 Tool Compensation Amount
(1)
! CAUTION
If the tool compensation amount or workpiece coordinate system offset amount is changed during
automatic operation (including during single block stop), the changes will be valid from the
command in the next block or after several subsequent blocks.
I - 141
3. Setup Screen
3.2 Tool Compensation Amount
Display items
(Note 1) The display range is when the minimum command unit is 1µm ("#1003 iunit"
= B, "#1041 I_inch" = 0).
(Note 2) Set at the radius value if parameter "#1019 dia” is "0", or at the diameter
value if this parameter value is "1".
(Note 3) Depending on the setting of parameter #8010(Max. value), the
setting/display range may be different from the above.
(Note 4) An absolute setting is applied even if the tool nose point is entered by
pressing the + Input menu and entering a value.
I - 142
3. Setup Screen
3.2 Tool Compensation Amount
2 6 1
7 0 5
X
R
Z 3 8 4
r
Menus
I - 143
3. Setup Screen
3.2 Tool Compensation Amount
Operation method (Setting "18.000" in the X-axis tool nose wear compensation amount of
compensation No. (1))
(2) Designate the Compensation No. The set number appears at the top of the area, and the
1 INPUT cursor moves.
(4) Input the X-axis tool nose wear The set value displays.
compensation amount.
18.000 INPUT
Settings can be made by pressing the
=INPUT key instead of the INPUT
key.
Old New
I - 144
3. Setup Screen
3.2 Tool Compensation Amount
Operation method ("-2.000" is calculated and set in the X-axis tool nose wear compensation amount
for compensation number (102).)
(2) Enter a value. The input value is added to the original value and
-2.000 +INPUT displays.
[Ex.] 18.000 displays if the original value is 20.000.
(20.000 – 2.000 = 18.000)
Old New
I - 145
3. Setup Screen
3.2 Tool Compensation Amount
Operation method (Erasing one line of tool compensation data at the cursor position)
(1) Move the cursor to the line to The cursor appears at the data item of the selected
be erased with the ↑ , ↓ , and compensation No.
keys.
(2) Press the Line clear and INPUT The menu keys are highlighted and a message
menu. displays confirming whether it is okay to erase.
The background color of the data to be erased
displays in light blue.
(3) Press the Y or INPUT key. The selected line of data (one line amount) is cleared
to zero.
To cancel the erasing, press a key other The data erased to zero displays at the top of the
than Y or INPUT . compensation data.
Operation method (Erasing the compensation data from compensation number 1 to 3.)
(2) Input the compensation number of the A message box displays to confirm whether it is okay
data range to be erased. to erase the data.
1/3 INPUT The background color of the data to be erased
displays in light blue.
(3) Press the Y or INPUT key. The compensation data for the selected compensation
number is erased, and the menu highlight returns to
Press a key other than Y or INPUT normal.
in order not to erase the data. The data cleared to zero displays at the top of the
compensation data.
(Note) If the INPUT key is pressed without selecting an compensation number, the line where the cursor
is located is erased.
I - 146
3. Setup Screen
3.2 Tool Compensation Amount
(2) Press the Line copy menu. The background color of the copied data changes to
light blue.
(4) Press the Line paste menu. The copied compensation data is written in the line
where the cursor is.
The background color returns to normal.
The copied compensation data is held until another
line is copied.
(Note 1) If the compensation data for the copied line is changed after the menu Line copy is pressed, the
data prior to the change is written when pasted.
(Note 2) It is not possible to paste the data to a different display (wear data, tool length data, tool nose data).
I - 147
3. Setup Screen
3.3 Tool Measurement
Table
When the measurement is completed, designate
the tool compensation No.
Finish
I - 148
3. Setup Screen
3.3 Tool Measurement
(internal computing)
When using the gauge block, etc., set the value
of the reference surface height.
Finish
(Note) Changing of the tool measurement type is determined based on the measurement axis (tool length
measurement axis, tool radius measurement axis) TLM reference length (parameter "#2016 tlml+") at
each measurement mode. When parameter "#2016 tlml+" is "0", the tool measurement type is tool
length measurement I.
I - 149
3. Setup Screen
3.3 Tool Measurement
Screen image
(1)
(2)
(4)
(3)
(5)
Display items
(Note) The TLM value counter differs according to the parameter "#1328 TLM type"
value.
0 : The position when the measurement switch was turned ON is displayed
as 0.
1 : The display is based on the machine zero point.
L meas : Z (Axis name) The axis selected in the parameters "#8711 TLM L meas axis" and "#8712 TLM D
R meas : X (Axis name) meas axis" is the target axis for the measurement.
(3) Reference surface height This displays a value for the reference surface height.
The setting range is from -99999.999 to 99999.999(mm)
I - 150
3. Setup Screen
3.3 Tool Measurement
(5) Tool compensation data This displays the tool compensation data. Depending on the tool compensation type
(I/II), the display details of the displayed tool compensation data will differ.
Menus
I - 151
3. Setup Screen
3.3 Tool Measurement
(1) Turn ON the measurement switch. The message "On mea 0" appears.
(2) Press the T-leng measure menu. The menu is highlighted, and the tool length
measurement starts. The measurement values are
displayed in "Meas value" during the measurement.
The menu T-leng measure is highlighted as a
default after the power is turned ON.
(3) Contact the measurement tool against the When the measurement tool contacts the sensor, the
sensor, using manual feed and manual skip position displayed in the measurement values
handle feed. Stop the feed when the tool counter.
contacts the sensor.
(5) Press the Offset write menu. The measurement values are written as a tool
compensation amount.
The wear amount is cleared to "0" for the tool
compensation type II.
(Note 1) The measurement values are not written if the cursor is in a position other than "Length" or
"Radius".
(Note 2) The axis returns and stops after contacting the sensor, but be careful not to move the axis after
that. If the axis moves after contacting the sensor, the distance that was actually moved will be
added to the measurement values counter, and the skip position will not be held.
(6) Turn OFF the measurement switch to The message "On mea 0" disappears.
finish measuring.
I - 152
3. Setup Screen
3.3 Tool Measurement
Display Meaning
On mea 1 This state is entered if a skip signal is input during manual measurement.
The "On mea 2" state is shifted to after deceleration stop is confirmed.
On mea 2 This is the state during the first retract operation.
The "On mea 3" state is shifted to after retracting the retract amount.
On mea 3 This is the state in which retract by the retract amount has completed.
If the skip after deceleration stop confirmation signal is ON, the status display will remain
the same.
The "On mea 0" state is shifted to when this state is reset.
On mea 4 This is the state during the second measurement.
If the skip signal is not input even after moving to the specified position, a warning will
appear, and the status display will remain the same.
The "On mea 0" state is shifted to when this state is reset
On mea 5 This state is entered when the skip signal is input during the second measurement.
The "On mea 6" state is shifted to after deceleration stop is confirmed.
On mea 6 This is the state during the second return operation.
The "On mea 0" state is shifted to after retracting the retract amount.
On mea 0 This state is entered when not in the "On mea 1" to "On mea 6" states.
The operating procedure of the tool radius measurement and submenu details are the same as when
measuring tool length.
(Use T-rad. measure instead of T-leng measure )
Refer to "Carrying out tool length measurement" for details.
I - 153
3. Setup Screen
3.3 Tool Measurement
Z-axis + tlml
Measurement point
Tool length
basic point
X-axis
tool length
(Note) Always set the measurement point in radius value, regardless of the diameter/radius command.
I - 154
3. Setup Screen
3.3 Tool Measurement
Measurement
X-axis measurement value
basic point
X-axis + tlml
Measurement
basic point
Z-axis
Z-axis + tlml measurement value
Tool length = Machine position - Measurement basic point (#2015 tlml-) - Measurement value
The expression above is used for automatic calculation in the measurement value input method.
Tool length
basic point
X-axis
tool length
(Note) Always set the measurement basic point in radius value, regardless of the diameter/radius
command.
I - 155
3. Setup Screen
3.3 Tool Measurement
X axis
Xm
Zp
Xp Zm
Z axis
X axis –
contact surface
Z axis +
contact surface Z axis tool compensation amount
I - 156
3. Setup Screen
3.3 Tool Measurement
Tool compensation amount = Machine coordinate position (machine coordinate position at the time of skip
input) - Measurement basic position (sensor position)
The expression above is used for automatic calculation in Manual tool length measurement II.
X-axis tool
length
I - 157
3. Setup Screen
3.3 Tool Measurement
Screen image
[Manual tool length measurement I: Basic point method]
(4)
(1)
(5)
(4)
(1)
(2) (5)
I - 158
3. Setup Screen
3.3 Tool Measurement
(4)
(3)
(5)
Display items
I - 159
3. Setup Screen
3.3 Tool Measurement
(5) Tool compensation data This displays the tool compensation data.
(Note 1) Cursor movement and part system changing operation are same as "Tool
compensation type III (L system)".
(Note 2) Automatically jumps to the compensation No. registered in "Tool No. (Tool
length measurement 2)" (PLC device) during manual tool length
measurement II. (Jumps even when the wear data is being displayed.) Note
that the ↑ , ↓ , , keys are disabled.
(Note) Measurement result and workpiece measurement value will be cleared when changing of part
systems, screens and measurement modes are carried out.
I - 160
3. Setup Screen
3.3 Tool Measurement
Menus
(Note) The data displayed on the tool compensation amount screen and the data displayed on "Tool
compensation data" in the tool measurement screen are not linked one another. (The wear data is not
necessarily displayed when the tool measurement screen has opened while the wear data is
displayed on the tool compensation amount screen.)
I - 161
3. Setup Screen
3.3 Tool Measurement
Carrying out tool length measurement (Manual tool length measurement I: Basic point method)
(2) Point the cursor to the position The cursor is displayed at compensation No.2, Z
(compensation No. 2, Z axis) where the axis.Calculation result of Z axis is displayed in
measurement result are to be set. "Measure value".
(3) Press the Offset write menu. The value displayed in "Measure value" is set in
compensation No.2, Z axis.
(Note 1) Compensation amount is written in diameter value for diameter command, in radius value for
radius command.
Carrying out tool measurement (Manual tool length measurement I: Measurement value input method)
(2) Point the cursor to the position The cursor is displayed at compensation No.3, X axis.
(compensation No. 3, X axis) where the (Note) In order to measure a different axis, point the
measurement result are to be set. cursor to the axis to be measured and perform
the following operations.
I - 162
3. Setup Screen
3.3 Tool Measurement
(5) Retract the tool and measure the The Work measure menu is highlighted and the cursor
workpiece. And then press the moves to the workpiece measurement value.
Work measure menu.
(6) Set the workpiece measurement result. 10 is set for the workpiece measurement value.
10 INPUT Highlight of the Work measure menu is canceled and
the cursor moves to the tool compensation data.
(7) Press the Offset write menu. "Measurement result - workpiece measurement value"
is set to compensation No.3, X axis.
(Note 1) Compensation amount is written in diameter value for diameter command, in radius value for
radius command.
(1) Select the tool to be measured with The tool to be measured is selected.
manual numerical value command. (Refer
to "3.11 Manual Numerical Value
Command" for details.)
(2) Set the compensation No. of the The compensation No. of the compensation data to be
compensation data to be set in "Tool No. set is selected.
(Tool length measurement 2)" (PLC
device).
(3) Set the compensation No. of the wear data The compensation No. of the wear data to be cleared
to be cleared in "wear compensation No. is selected.
(tool presetter)" (PLC device).
(4) Turn the measurement switch ON. "On meas" is displayed. Guide drawing for manual tool
length measurement II is displayed. Tool
compensation data is displayed, placing the
compensation No. set in "Tool No. (Tool length
measurement 2)" (PLC device) at the top.
I - 163
3. Setup Screen
3.3 Tool Measurement
(5) Move the additional axis in the minus Measurement value is set for the additional axis of the
direction by manual feed and have the tool compensation No. set in "Tool No. (Tool length
nose contact with the touch sensor. measurement2)" (PLC device)
(Note 1) When entering the sensor area, the axis can be moved only in one direction selected from +X,
-X, +Z, -Z, (+Y、-Y). If two axes are moved simultaneously, measurement will not be carried out.
At this time, "E78 AX UNMATCH (TLM)" is displayed and the axis movement stops.
(Note 2) If the tool nose is contacting the sensor, the axis can be moved only in the direction moving
away from the sensor. Whether or not the tool nose is detached from the sensor can be judged
by the following conditions.
● The sensor signal has been turned OFF for 500ms or more.
● The tool nose is moved 100µm or more after the sensor signal has turned OFF.
The above conditions are set with parameter "#1227 aux11/bit2".
I - 164
3. Setup Screen
3.4 Tool Registration
A tool No. is assigned to each tool to make the tools installed on the machine recognizable to the NC. The
tool No. is registered corresponding to the magazine pot and spindle where that tool is installed, and the
standby location.
When the tool No. and magazine pot are changed by a tool selection command or tool replacement
command, the new tool No. is displayed
When not making an arbitrary setting for the number of registered tools, there are maximum 3 magazines,
and up to 120 tools can be registered for each magazines. When making an arbitrary setting, there are a
maximum of 5 magazines, and up to 360 tools can be registered for all magazines.
This function differs depending on the specifications of the machine tool builder. Refer to the instruction
manual issued by the machine tool builder for details.
(2)
(1)
(3)
Inputting an address key, such as MST, displays manual numerical value command window where manual
numerical value command is executed.
Display items
I - 165
3. Setup Screen
3.4 Tool Registration
Menus
I - 166
3. Setup Screen
3.4 Tool Registration
(1) Press the menu Magazn 2 . The tool data of the set magazine No. appears.
(1) Designate the pot No. The tool data appears with the designated pot No. at
the head.
Pot No. 21 INPUT
The cursor moves to the tool No. setting column.
(2) Input the tool number. The input tool number displays and the cursor moves
50 INPUT to the next tool number.
I - 167
3. Setup Screen
3.4 Tool Registration
(1) Set the value after the PLC command The set value displays in the PLC command setting
menu. field, and the PLC command setting mode is enabled.
The function of the command depends on the machine
PLC command 12 INPUT
tool builder’s specifications.
(Note) Select the PLC Command menu again before pressing the INPUT key, then the menu
highlight returns to normal, and the PLC command setting mode becomes disable.
(2) Press the menu PLC command , or the The PLC command setting mode is released, and the
menu highlight returns to normal.
key again to finish setting.
(1) Press the Spindle standby menu. The cursor appears at the top tool No. of
spindle/standby.
In addition, the first "D" column is highlighted.
(3) Input a new tool No. The tool No. changes. The cursor moves to the next
50 INPUT (Note1) tool No.
(4) Press the Spindle standby menu again The spindle/standby setting mode is cancelled.
or key to quit the spindle/standby
setting mode.
(Note 1) When the Spindle standby menu again or key is pressed before pressing the INPUT
key, the spindle/standby setting mode will be cancelled and the set data will be ignored.
(Note 2) Move the cursor with → key to set the "D" data.
(1) Press the Spindle standby menu. The cursor appears at the top tool No. of
spindle/standby.
In addition, the first "D" column is highlighted.
(2) Move the cursor to the tool No. to be The tool No. of spindle/standby changes to “0”.
erased and input “0”.
0 INPUT
(Note 1) Move the cursor with → key and set “0” to erase the "D" data as the same manner as the tool
No.
I - 168
3. Setup Screen
3.4 Tool Registration
Operation method (Selecting a magazine number and erasing the tool registration data.)
(1) Press the menu Magazn 2 . The tool registration data of the selected magazine No.
appears.
(2) Press the menu Magazn clear . A message displays confirming whether it is okay to
erase.
(3) Press the Y or INPUT key. All selected magazine tool data (tool number and D) is
erased.
Spindle/standby tool data is not erased.
I - 169
3. Setup Screen
3.5 Tool Life Management
The life management data of the tool usage conditions, etc., is set and displayed.
The tool life management specifications differ for the M and L system.
Inputting an address key, such as MST, displays manual numerical value command window where manual
numerical value command is executed.
<M system>
Tool life management I
The usage time or No. of uses of the tool commanded in the program is incremented, and the usage
state of that tool is monitored.
I - 170
3. Setup Screen
3.5 Tool Life Management
<L system>
Tool life management I ............ Tool life data display
The tool usage time and usage count indicated in the program is accumulated, and the usage status for
that tool is monitored. Tool life management can be performed for a maximum of 80 tools (tool Nos. 1 to
80).
(a) Time based control
The cutting time (G01, G02, G33 etc.) after performing the tool selection command (T) is calculated
in the tool usage time corresponding to the designated tool.
A warning is issued if the usage time at the time the tool selection command is performed reaches
the life time.
(b) Usage count based control
The tool usage count corresponding to the designated tool No. increases each time the tool
selection command (T) is performed.
A warning is issued if the usage count at the time the tool selection command is performed exceeds
the life time.
Tool life management II ........... Tool life data display / registration group list display
The life (usage time, usage count) of each tool is controlled, and if the life is reached, the same spare
tools are selected and used one by one from the group to which that tool belongs.
{ Group count : Multi-part system spec. : max. 40 groups for each part system
Single part system spec.: max. 80 groups
{ No. of tools in group : Max. 16
The tool life management related parameters (basic shared parameters) are shown below.
The tool life management screen is made up of the group list display screen and the life management
data screen.
(There is no group list display screen in L system tool life management 1. Only the life management data
screen exists.)
Refer to the following sections for details of the display contents, menus, and an explanation of the
operations for each screen.
I - 171
3. Setup Screen
3.5 Tool Life Management
<M system>
When changing from a group unit display to the group list display, the cursor displays at the group No. at
the group unit display.
(1)
I - 172
3. Setup Screen
3.5 Tool Life Management
<L system>
This screen is enabled only for tool life management type II (parameter "#1096 T_Ltyp" = 2).
The tool life management data currently being used and the group list display.
(1)
(10)
(3) (9)
(4) (8)
(7)
(5)
(6)
(2)
[CHOSEN TOOL]
Display item Details Display range
(3) Group Displays the life management group No. currently being used. 1 to 9999
(4) Tool No. Displays the tool No. currently being used. 1 to 999999
(5) Comp No. Displays the compensation No. currently being used. 1 to 80
(6) Mthd Displays whether the group currently being used is controlled by 0: Time
the usage time or usage count. 1: Count
(7) Used Displays the usage data for the tool currently being used. Usage time:
0 to 99999999 (s)
Usage count:
0 to 999999 (set)
(8) Total Displays the total usage data for the tool currently being used. Usage time:
In the case of tools using multiple compensation Nos., the total 0 to 99999999 (s)
usage data for all compensation Nos. displays. In the case of only Usage count:
one compensation No., the same value as "Used" displays. 0 to 999999 (set)
(9) Life Displays the life value for the tool currently being used. Usage time:
0 to 99999999 (s)
Usage count:
0 to 999999 (set)
(10) ST Displays the status of the tool currently being used. 0: Unused tool
1: Used tool
2: Normal life tool
3: Skipped tool
I - 173
3. Setup Screen
3.5 Tool Life Management
(2) Designate the group No. to be registered. The life management data for the selected group No.
25 INPUT displays empty.
(Note 1) An error occurs if the group No. duplicates a pre-existing group No.
(Note 2) The group is not registered if the following operations are performed after newly registering a
group No..
• The application is exited without registering even 1 item of tool life data.
• The screen is changed to that of other than the group unit display.
• The part system is changed.
(2) Designate the group to be erased. The selected group No. is erased.
72 INPUT
If nothing is input in the input area, the group at the cursor location is erased.
I - 174
3. Setup Screen
3.5 Tool Life Management
(1) Press the menu Grp all delete . The confirmation message appears.
(2) Designate the group to be erased. All the registered groups and their tool life
72 INPUT management data is erased.
(Note 1) If no group has been registered, the operation message "Can't delete all groups" will appears.
(2) Press the menu Group change key. The menu is highlighted.
(3) Set the new group No.. The group No. changes to "20".
20 INPUT
(2) Press the menu T-life group or The screen changes to the group unit display and the
INPUT keys. group No. "5" tool life management data displays.
<M sysem>
<L system>
I - 175
3. Setup Screen
3.5 Tool Life Management
(6)
(1) (7)
(2)
(3)
(4)
(5)
(8)
(9)
(10)
I - 176
3. Setup Screen
3.5 Tool Life Management
Tool status
Machine manufacturer release
Tool status
0 : Unused tool
Normally set to "0" when the tool is replaced with a new
tool.
1 : Used tool
This becomes "1" when the cutting actually starts.
2 : Normal life tool
This becomes "2" when the usage data (usage time and
No. of uses) exceeds the life data.
3 : Tool abnormality 1 tool
4 : Tool abnormality 2 tool
(Note) Item 3 and 4 differ depending on the machine tool builder
specifications.
I - 177
3. Setup Screen
3.5 Tool Life Management
(M system)
Display item Details Display range
(5) Mthd
I - 178
3. Setup Screen
3.5 Tool Life Management
(M system)
Display item Details Display range
(10) Used This displays the usage data for individual tools based on the Usage time:
method specified for the tool life management method. 0 to 4000 (min)
(Note) This data is not counted during machine lock, auxiliary No. of mounting
function lock, dry run or for a single block. times:
0 to 65000 (set)
No. of uses:
0 to 65000 (set)
(Note 1) The "Length compensation" and "Radius compensation" calculation/direct compensation amount
setting/display range are as follows based on a combination of settings of "#1003 inunit (input unit)"
and "#1041 I_inch (initial inch)".
I - 179
3. Setup Screen
3.5 Tool Life Management
Menus (M system)
I - 180
3. Setup Screen
3.5 Tool Life Management
(2) Designate the group No. to be displayed. The tool life data of the designated group No. appears,
12 INPUT and the cursor moves to the head of the data.
(Note) If a group No. that does not exist is designated, a message appears to confirm the creation of a
new No. A new group is created if Y or INPUT is pressed.
(1) Press the Grp No. change menu. The menu is highlighted.
(2) Designate the group No. after changing. The group No. changes to "112".
112 INPUT
(Note) An error occurs if the group No. duplicates a pre-existing group No.
(1) Move the cursor to the data to be set using The menu is highlighted.
the , ↑ , ↓ , and
keys.
It is possible to move to the line after the
registered line.
Set a tool No. for this line to newly register
tool life management data.
(Note 1) The other settings will be invalid when the tool ST (status) setting data are not set.
(Note 2) The same tool cannot be registered in more than one group.
(Note 3) If the tool No. is not set, the other data cannot be set.
(Note 4) Change the "Method" to initialize the related items.
Change the tool life management method (the 1st digit) to clear the "Life" and "Usage", and also
change the units.
Change the tool radius compensation data (the 2nd digit) to clear the "Radius Compensation".
Change the tool length compensation data (the 3rd digit) to clear the "Length Compensation".
Figures after the decimal point are also changed in line with the specifications.
I - 181
3. Setup Screen
3.5 Tool Life Management
(4) Press the Line paste menu. The copied tool life management data is written to the
data (excluding the tool No.) in the line where the
cursor is located.
The background color returns to normal.
The cursor moves to "ST".
(Note 1) Once copied, the data is held until a new data item is copied.
(Note 2) It is not possible to paste into a line for which a tool No. has not been set.
Operation method (Erasing one line of tool life management data) (M system)
(2) Press the menu Line clear and The menu is highlighted.
A message displays confirming whether it is okay to
INPUT keys.
erase the data.
The background color of the area to be erased
changes to light blue.
(3) Press the Y or INPUT key. One line of the selected life management data is
erased and the menu highlight returns to normal.
Press a key other than Y or INPUT The next line moves up after erasing.
in order not to erase the data.
I - 182
3. Setup Screen
3.5 Tool Life Management
(2) Set the range to be erased by marking the A message appears to confirm the erasing.
first and last # Nos. with a "/", and press The background color of the area to be erased
INPUT key. changes to light blue.
122/125 INPUT
(3) Press the Y or INPUT key. The tool life data corresponding to the designated #
No. is erased, and the menu highlight returns to
Press a key other than Y or INPUT normal.
in order not to erase the data. The next line after the erased range moves up.
(2) Set the No. of the group to be registered. A new group is created and the life management data
25 INPUT displays containing no data.
(2) Press the Group delete menu. A message appears to confirm the erasing.
(3) Press the Y or INPUT key. All the tool life management data for the displayed
group No. is erased and the previous group No. data
displays.
Returns to the group list displays if all groups are
erased.
I - 183
3. Setup Screen
3.5 Tool Life Management
3.5.3 Displaying the Life Management Data (L system: Tool life management I)
The tool life management data can be set and displayed. Use the / keys to scroll between screens
if all of the registered tools cannot be displayed on one screen.
I - 184
3. Setup Screen
3.5 Tool Life Management
Menus (L system)
(2) Press the menu Line copy . The background color of the copied data changes to
light blue.
(4) Press the Line paste menu. The copied tool life management data is written to the
data in the line where the cursor is located.
The background color returns to normal.
(Note 1) Once copied, the data is held until a new data item is copied.
I - 185
3. Setup Screen
3.5 Tool Life Management
Operation method (Erasing one line of tool life management data) (L system)
(2) Press the menu Line clear and The menu is highlighted.
A message displays confirming whether it is okay to
INPUT keys.
erase the data.
The background color of the area to be erased
changes to light blue.
(3) Press the Y or INPUT key. One line of the selected life management data is
erased and the menu highlight returns to normal.
Press a key other than Y or INPUT The next line moves up after erasing.
in order not to erase the data.
(2) Set the erasing range by marking the first A message displays confirming whether it is okay to
and last # Nos. with a "/", and press erase the data.
INPUT key. The background color of the area where the data is
erased changes to light blue.
122/125 INPUT
(3) Press the Y or INPUT key. The tool life data corresponding to the designated #
No. is erased, and the menu highlight returns to
Press a key other than Y or INPUT normal.
in order not to erase the data. The next line after the erased range moves up.
(Note) If the INPUT key is pressed without setting a # No., the line at the cursor is erased.
I - 186
3. Setup Screen
3.5 Tool Life Management
3.5.4 Displaying the Tool Life Management Data in Group Units (L system: Tool life
Management II)
The tool life management data of an arbitrary group is set and displayed. If the registered tools cannot be
displayed on one screen, scroll the screen using the or key.
This screen is enabled only for tool life management II ("#1096 T_Ltyp" = 2).
(1)
(3)
(2)
(4) (8)
(5) (7)
(6)
By setting parameter "#1107 Tllfsc", it is possible to select the life management data display mode for
multiple groups.
"#1107 Tllfsc" setting value 0 1 2
No. of display groups 1 2 4
Max. No. of registered tools 16 8 4
I - 187
3. Setup Screen
3.5 Tool Life Management
<Group information>
Display item Details Setting range
(1) Group Life management group No. 1 to 9999
(2) Form This displays whether to control the currently displayed group 0 : Hours
in usage hours or usage count. 1 : Times
(3) Life This sets the tool life data for the currently displayed group. Usage time:
The following tool life data units display based on the control 0 to 99999999 (s)
method. Usage count:
Usage time : (s) 0 to 999999 (set)
Usage count : (set)
I - 188
3. Setup Screen
3.5 Tool Life Management
Menus (L system)
Group This creates a new group and displays the life management data A "Registering a group"
regist containing no data.
(2) Designate the group No. to be displayed. The tool life data of the designated group No. appears,
12 INPUT and the cursor moves to the head of the data.
(Note) If a group No. that does not exist is set, a message appears to confirm the creation of a new No..
A new group is created if Y or INPUT is pressed.
When creating a new group, set the method and life data at the end of the group No., separating
the data with a "/". If the method and life data are omitted, a new group is created with method =
0 (usage time), and life data = 0.
I - 189
3. Setup Screen
3.5 Tool Life Management
(1) Press the Grp No. change menu. The menu is highlighted.
(2) Designate the group No. after changing. The group No. changes to "112".
112 INPUT
(Note) An error occurs if the group No. duplicates a pre-existing group No.
(Note 1) It is not possible to set any other data if the tool No. and compensation No. have not been set.
(2) Press the menu Line copy . The background color of the copied data changes to
light blue.
(4) Press the Line paste menu. The copied tool life management data is written to the
data in the line where the cursor is located.
The background color returns to normal.
The cursor moves to "Tool No.".
(Note 1) Once copied, the data is held until a new data item is copied.
I - 190
3. Setup Screen
3.5 Tool Life Management
Operation method (Erasing one line of tool life management data) (L system)
(2) Press the menu Line clear and The menu is highlighted.
A message displays confirming whether it is okay to
INPUT keys.
erase the data.
The background color of the area where the data is
erased changes to light blue.
(3) Press the Y or INPUT key. One line of the selected life management data is
erased and the menu highlight returns to normal.
Press a key other than Y or INPUT in The next line moves up after erasing.
order not to erase the data.
(2) Set the erasing range by marking the first A message displays confirming whether it is okay to
and last # Nos. with a "/", and press erase the data.
INPUT key. The background color of the area where the data is
erased changes to light blue.
1/5 INPUT
(3) Press the Y or INPUT key. The tool life data corresponding to the designated #
No. is erased, and the menu highlight returns to
Press a key other than Y or INPUT normal.
in order not to erase the data. The next line after the erased range moves up.
(Note) If the INPUT key is pressed without setting a # No., the line at the cursor is erased.
(2) Set the No. of the group to be registered. A new group is created and the life management data
25/1/3000 INPUT displays containing no data.
(Note 1) If the method and life data are omitted, a new group is created with method = 0 (usage time),
and life data = 0.
(Note 2) An error occurs if the same group No. already exists.
(Note 3) The group is not registered if one of the operations below is performed after registering a new
group No.
• If the application is exited without registering even 1 item of tool life data.
• If the screen is changed to that of other than the group unit display.
• The part system is changed.
I - 191
3. Setup Screen
3.5 Tool Life Management
Operation method (Changing the active area for multiple group displays) (L system)
(1) Press the Group change menu. The cursor indicating the active status moves to the
next group.
I - 192
3. Setup Screen
3.6 Workpiece Coordinate System Offset
This function allows the user to set and display the coordinate system offset controlled by the NC.
Using the option, the number of coordinate system offset sets can be increased by 48 or 96 sets.
(1)
(2)
(3)
Inputting an address key, such as MST, displays manual numerical value command window where manual
numerical value command is executed.
Display items
(2) EXT offset area This displays or sets the offset amount for the external workpiece system.
(3) G92/G52 offset area This displays the offset amount for G92 or the local coordinate system.
The offset amount of the corresponding local coordinate system (G52) is displayed
only when the cursor is at G54 to G59.
! CAUTION
If the tool compensation amount or workpiece coordinate system offset amount is changed during
automatic operation (including during single block stop), the changes will be valid from the
command in next block or after several subsequent blocks.
I - 193
3. Setup Screen
3.6 Workpiece Coordinate System Offset
Menus
This sets the workpiece coordinate system offset so that the current C 3.6.3 Setting the Work
Easy
setting machine coordinate becomes the workpiece coordinate zero point. Piece Coordinate Origin
Only the axis at the cursor position is set.
This displays the G54 - G59 workpiece coordinate system offset C 3.6.1 Setting the
G54-G59 amount. The cursor moves to the G54 offset. This menu can be used Coordinate System
when the G54 – G59 offsets are not displayed. Offset
Enter the P number displayed at the screen to display the extension A
workpiece coordinate (G54.1 Pn) offset in the coordinate system
G54.1 offset area. This menu is not displayed if the extension workpiece
P coordinate system offset option is disabled.
If the local coordinate system offset (G52) displays in the G92/G52
area, the display changes to G92.
This displays the G92 or G52 coordinate system offset amount. The C
Coord
G92/G52 G92 offset data is always displayed when the cursor is not at the G54
to G59 offset data.
All All coordinate system offset amounts for all axes are erased with the A 3.6.2 Erasing the
clear exception of G92 and EXT. Coordinate System
Offset Amount
All axs This erases the local offset data for all axes corresponding to the A
clear offset data of the coordinate system where the cursor is located.
This can be selected when the number of enabled axes is 6 or over. C
Next
axis The displayed axes are changed to axes 1 – 5, and axis 6 and over.
(Note) This displays when there are 6 or more axes.
I - 194
3. Setup Screen
3.6 Workpiece Coordinate System Offset
Operation method (Setting the workpiece coordinate system G54 - G59 offset amount)
(1) Press the G54-G59 menu. The G54 - G59 workpiece coordinate system offset
displays.
(4) Set the offset amount. The set data displays and the cursor moves to the next
122 INPUT data.
This setting can be made by pressing the
menu =INPUT key instead of the
INPUT key.
(Note) It is possible to perform additional input by pressing the menu +INPUT key instead of the
INPUT or menu =INPUT keys.
[Ex.] If the original data is 122.000:
1.234 [+INPUT] → 122.000 + 1.234 = 123.234
Set the external coordinate system offset amount to keep the current workpiece coordinate system offset
amounts from G54 to G59, and also apply an offset to the entire system.
Furthermore, it is also possible to use the data transfer function to write data directly to the external
coordinate system offset (EXT).
(Refer to "6.2 Input/output screen" for details of the data transfer function.)
I - 195
3. Setup Screen
3.6 Workpiece Coordinate System Offset
Operation method (Erasing the coordinate system (excluding G92) offset amount where the cursor is
displayed for all axes.)
(1) Press the menu All axs clear menu. The menu is highlighted.
A message displays confirming whether it is okay to
erase the data.
(2) Press the Y key. All of the coordinate system indicated by the cursor is
cleared to zero.
In addition, all axes data of the local offset (G52) for
the coordinate system will be erased.
Operation method (Erasing all axis offset data of all coordinate systems (excluding G92 and EXT))
(1) Press the menu All clear menu. The menu is highlighted.
A message displays confirming whether it is okay to
erase the data.
I - 196
3. Setup Screen
3.6 Workpiece Coordinate System Offset
Use the tab keys to change the coordinate system offset cursor position.
EXT G92
Changing the coordinate system offset using the page change keys (previous page: , next page: )
Use the page change keys to change the coordinate system offset display as shown below.
An option is required for the G54.P1 - P96 workpiece coordinate system offset display.
I - 197
3. Setup Screen
3.7 Workpiece Measurement
■For surface measurement (As for the hole or width measurement, the guide drawing differ.)
(2)
(1)
(3)
(4)
(6)
(5)
(1)
(3)
(7)
(4)
(8) (6)
(5)
(9)
Inputting an address key, such as MST, displays manual numerical value command window where manual
numerical value command is executed.
I - 198
3. Setup Screen
3.7 Workpiece Measurement
Display items
I - 199
3. Setup Screen
3.7 Workpiece Measurement
Menus
Hole This enables hole measurement. (The cursor moves to the B 3.7.2 Carrying Out Hole
meas measurement counter point A.) Measurement
Width This enables width measurement. (The cursor moves to the B 3.7.3 Carrying Out Width
meas measurement counter point A.) Measurement
Rotate This enables rotation measurement. (The cursor moves to the B 3.7.4 Carrying Out
meas measurement counter point A.) Rotation Measurement
This changes the axes displayed at the coordinate system offset and C
Next measurement position counter from axis 1 - 5, and axis 6 and over.
axis
(Note) This displays when the number of enabled axes is 6 or over.
Center This sets the center shift amount. (The cursor moves to the 1st axis of A 3.7.4 Carrying Out
shift "center shift (S)" when this is selected.) Rotation Measurement
Rotate This sets the coordinate rotation center. (The cursor moves to the 1st A
center axis of "coordinate rotation center" when this is selected.)
Rotate This sets the coordinate rotation angle. (The cursor moves to the A
angle "coordinate rotation angle" when this is selected.)
I - 200
3. Setup Screen
3.7 Workpiece Measurement
Hole
meas
Width
meas
Rotate
meas
I - 201
3. Setup Screen
3.7 Workpiece Measurement
Outline
When carrying out surface measurement, the position of each axis is measured and the measurement results
are set in the workpiece coordinates system offset. The measurement position displays at the measurement
counter.
(Note) The sign (+ and -) changes depending on the direction of the axis moved last.
Item Reference
Sensor radius "#8702 Tool Dia"/2
Sensor length "#8701 Tool Length "
Operation method
(3) Turn ON the measurement switch on the The message "On meas" appears.
machine operation board.
I - 202
3. Setup Screen
3.7 Workpiece Measurement
(7) Press the Coord write menu. The value achieved by adding or subtracting the
external workpiece offset to or from the X axis
measurement position based on the "#8709 Ext work
sign rvs" is set in workpiece coordinate system
selected at (6).
The measurement counter displays blank.
(9) Return the tool to the reference position, The message "On meas" disappears.
and turn the measurement switch OFF.
Outline
When carrying out hole measurement, three positions (A, B, and C) are measured, and the hole center
position calculated from the three measured positions is set in the workpiece coordinate system offset. The
measurement position displays at the measurement counter.
(Note) The skip past amount is added for only the axis that moved last.
The sign ( + or - ) of the past amount depends on the movement direction of the axis.
Item Reference
Center compensation (H) "#8703 OFFSET X"
Center compensation (V) "#8704 OFFSET Y"
Skip past amount (horizontal axis) "#8707 Skip past amout (H)"
Skip past amount (vertical axis) "#8708 Skip past amout (V)"
I - 203
3. Setup Screen
3.7 Workpiece Measurement
Operation method
(1) Press the Hole meas menu. The menu is highlighted and the cursor displays at
point A.
Use the ↑ , ↓ keys to move to points B and C.
(3) Turn ON the measurement switch on the The message "On meas" appears.
machine operation board.
(8) Press the Coord write menu. The hole center position is measured, and based on
the "#8709 Ext work sign rvs", value achieved by
adding or subtracting the external workpiece to or from
the measurement result is set in workpiece coordinate
system selected at (7). The measurement counter
displays blank.
(9) Return the tool to the reference position, The message "On meas" disappears.
and turn the measurement switch OFF.
I - 204
3. Setup Screen
3.7 Workpiece Measurement
Outline
When carrying out width measurement, two positions (A, and B) are measured, and the width center position
calculated from the two measured positions is set in the workpiece coordinate system offset. The
measurement position displays at the measurement counter.
(Note) The skip past amount is added for only the axis that moved last.
The sign ( + or - ) of the past amount depends on the movement direction of the axis.
Item Reference
Sensor length "#8701 Tool Length"
Center compensation (H) "#8703 OFFSET X"
Center compensation (V) "#8704 OFFSET Y"
Skip past amount (horizontal axis) "#8707 Skip past amout (H)"
Skip past amount (horizontal axis) "#8708 Skip past amout (V)"
Operation method
(1) Press the Width meas menu. The menu is highlighted and the cursor displays at
point A.
Use the ↑ , ↓ keys to move to points A and B.
(3) Turn ON the measurement switch on the The message "On meas" appears.
machine operation board.
I - 205
3. Setup Screen
3.7 Workpiece Measurement
(6) Similarly, position the tool against the Upon contact, the axis automatically contacts the
opposite side. groove wall again. The skip position displays in the
measurement counter point B.
(8) Press the Coord write menu. The width center position is measured, and based on
the "#8709 Ext work sign rvs", value achieved by
adding or subtracting the external workpiece offset to
or from the measurement result is set in workpiece
coordinate system offset G55 (coordinate system
selected at (7)). The measurement counter displays
blank.
(10) Return the tool to the reference position, The message "On mea" disappears.
and turn the measurement switch OFF.
I - 206
3. Setup Screen
3.7 Workpiece Measurement
Outline
When carrying out rotation measurement, the offset (rotation center and rotation angle) of the rotary
coordinate system is measured, and the results are set to the workpiece coordinate system offset (rotation
center) and the parameters "#8623 Coord rot centr(H)", "#8624 Coord rot centr(V)", and "#8627 Coord rot
angle".
(Note) The skip past amount is added for only the axis that moved last.
The sign ( + or - ) of the skip past amount depends on the movement direction of the axis.
Item Reference
Center compensation (H) "#8703 OFFSET X"
Center compensation (V) "#8704 OFFSET Y"
Skip past amount (horizontal axis) "#8707 Skip past amout (H)"
Skip past amount (vertical axis) "#8708 Skip past amout (V)"
(1) Press the Rotate meas menu. The pop-up window for the rotation measurement
appears.
The measurement counter becomes active and the
cursor appears at the 1st axis.
(3) Input the center shift amount (Si). The value is input and the cursor moves to the 2nd
10.000 INPUT axis.
(4) Input the center shift amount (Sj). The value is input, however, the cursor does not move.
-5.000 INPUT
(5) Press the Center shift menu. The menu highlight returns to normal.
The measurement counter becomes active and the
cursor appears at the 1st axis.
"C shift (S)" column active display returns to normal.
I - 207
3. Setup Screen
3.7 Workpiece Measurement
Operation method (Setting the center and angle of the coordinate rotation)
The setting of the parameters "#8623 Coord rot centr(H)", "#8624 Coord rot centr(V)", and "#8627 Coord rot
angle" can be changed.
(1) Press the Rotate meas menu. The pop-up window for the rotation measurement
appears.
The measurement counter becomes active and the
cursor appears at the 1st axis.
(3) Input data in the 1st axis of "Coord center" The value is input and the cursor moves to the 2nd
column. axis.
0 INPUT
(4) Input data in the 2nd axis of "Coord center" The value is input, however, the cursor does not move.
column.
0 INPUT
(5) Press the Rotate center menu. The menu highlight returns to normal.
The measurement counter becomes active and the
cursor appears at the 1st axis.
"Coord center" column active display returns to
normal.
(Note) Set the angle of the coordinate rotation in the same manner.
I - 208
3. Setup Screen
3.7 Workpiece Measurement
Operation method (Carrying out the rotation measurement using touch sensor to set the
measurement results to the workpiece coordinate offset)
(1) Press the Rotate meas menu. The menu is highlighted and the cursor appears at
point A.
The cursor can be moved to A, B, or C, using ↑ and
↓ keys.
(3) Set the following parameters to "0". The value is input, however, the cursor does not move.
#8623 Coord rot centr(H)
#8624 Coord rot centr(V)
#8627 Coord rot angle
(Note) These parameter should be set to "0" to set the measured value to them.
If the value other than "0" has been set, an error occurs when writing to the coordinate
system.
(4) Turn the manual absolute switch ON. The value is input and the cursor moves to the 2nd
axis.
(6) Turn ON the measurement switch on the The message "On meas" appears.
machine operation board.
(7) Referring to "Setting the center shift The menu highlight returns to normal.
amount", set the center shift amount. The measurement counter becomes active and the
cursor appears at the first axis.
This setting is not necessary if the
"Coord center" column active display returns to
coordinate rotation center is served as the
normal.
workpiece coordinate zero point.
I - 209
3. Setup Screen
3.7 Workpiece Measurement
(11) Press the Coord write menu. The hole center position is measured, and based on
the "#8709 Ext work sign rvs", value achieved by
adding or subtracting the external workpiece to or from
the measurement result is set in workpiece coordinate
system selected at (7). The measurement counter
displays blank.
(12) Return the tool to the reference position, The message "On meas" disappears.
and turn the measurement switch OFF.
I - 210
3. Setup Screen
3.7 Workpiece Measurement
Return
amount
Return
amount
The return speed for (3) and (6) is 40 times the measurement parameter feedrate (#8706). However, if
the return speed is faster than rapid feedrate (override 100%), the rapid feedrate will become the return
speed.
I - 211
3. Setup Screen
3.7 Workpiece Measurement
Workpiece
Z axis
Workpiece coordinate
zero point
(5)
(1)
(2)
(6)
(3)
(4)
Manual numerical value command can be executed when manual numerical value command window is
displayed by inputting an address key such as MST, etc.
I - 212
3. Setup Screen
3.7 Workpiece Measurement
Display items
I - 213
3. Setup Screen
3.7 Workpiece Measurement
Menus
I - 214
3. Setup Screen
3.7 Workpiece Measurement
(1) Execute the reference position return. The coordinate system is established.
(Note 1) If the workpiece is measured without
establishing the reference position return, the
operation message "Meas axis not returned
to ref. position" appears.
(5) Issue the T command with MDI operation, The tool is selected.
etc. (Note 1) Set the selected tool compensation No. in R
register.
The set R register differs according to
parameter setting and the state of the tool
presetter sub-side valid signal.
(Note 2) Set the "tool length/wear data" for the tool
being used beforehand.
(7) Input the workpiece measurement signal. The Z axis external workpiece coordinate offset data is
automatically calculated from the tool compensation
data of the used tool and the machine value at the
point this signal is input. The results are set as the
data.
(8) Turn "Tool length measurement 2" signal Measurement of the external workpiece coordinate
OFF. offset is completed.
I - 215
3. Setup Screen
3.7 Workpiece Measurement
(1) Execute the reference position return. The coordinate system is established.
(Note 1) If the workpiece is measured without
establishing the reference position return, the
operation message "Meas axis not returned
to ref. position" appears.
(3) Select an arbitrary coordinate system The designated coordinate system offset is selected.
offset. (Note 1) When switching to an arbitrary coordinate
system offset display, press one of these;
"Coord G54 - G59" "Coord G54.1P" menu or
page key.
(7) Press the menu MeasVal take in. The workpiece measurement is executed.
The operation message "OK? (Y/N)" appears, so
press the Y or INPUT.
The Z axis external workpiece coordinate offset data is
automatically calculated from the tool compensation
data of the used tool and the machine value at the
point this signal is input. The results are set as the
data.
I - 216
3. Setup Screen
3.7 Workpiece Measurement
Details of automatic calculation expression (When the workpiece measurement signal is used)
The external workpiece coordinate offset data is automatically calculated with the following expression.
External workpiece coordinate offset = Machine coordinate value - Tool compensation data
The tool compensation data used for the measurement is selected with the base specification parameter
"#1226 aux10 bit0".
#1226 aux10 bit0 Tool compensation data
0 Tool length data + nose wear data
1 Tool length data
Machine value
Tool
compensation
amount Tool rest Basic machine
coordinate zero point
Details of automatic calculation expression (When the MeasVal take in menu is used)
The workpiece coordinate offset data is automatically calculated with the following expression.
The calculation expression changes according to basic specification parameter "#8709".
When "#8709" is "0":
Workpiece coordinate offset
= Machine coordinate value - External workpiece coordinate offset - Tool compensation data
When "#8709" is "1":
Workpiece coordinate offset
= Machine coordinate value + External workpiece coordinate offset - Tool compensation data
The tool compensation data used for the measurement is selected with the base specification parameter
"#1226 aux10 bit0".
#1226 aux10 bit0 Tool compensation data
0 Tool length data + nose wear data
1 Tool length data
Workpiece
coordinate offset External workpiece
coordinate offset
Machine value
Tool
compensation
amount Tool rest Basic machine
coordinate zero point
I - 217
3. Setup Screen
3.7 Workpiece Measurement
For the compensation No. of the tool length and tool nose wear data used by automatic calculation, the No.
set in R register in the following table is used.
Tool length Tool nose wear
#1218
#1098 Tlno. #1130 set_t compensation No. compensation No.
aux02 bit4
Main side Sub-side Main side Sub-side
R2600, R2604,
0 0/1 0/1
R2601 R2605
R2600, R2604,
0 R536, R537
0 R2601 R2605
1 1 R2602, R2606,
1 0/1 R2603 R2607
(Note 1) When the compensation No. is 0, the compensation amount will be calculated as "0".
(Note 2) If the compensation No. exceeds the number of specified offset sets, the operation message
"Offset No. not found" appears.
(Note 3) If the input data exceeds the setting range, the operation message "Data range error" appears.
(Note 4) If the data protect key 1 is valid, the operation message "Data protect" appears.
(Note 5) Whether to use the main side or sub-side is selected with the tool presetter sub-side valid signal.
(OFF: Main side, ON: Sub-side)
(Note 6) Set the compensation No. in R register by the BCD code.
I - 218
3. Setup Screen
3.8 User Parameters
(1)
(2)
(1)
(2)
I - 219
3. Setup Screen
3.8 User Parameters
Display items
Menus
Fixed
cycle
Control
param
Operate
param
I/O
param
Ethernet
param
Link
param
Subpro
stor
Axis
param
Barrier
data
Hi-prec
param
Hi-prec
axis
This selects an arbitrary parameter number. A 3.8.1 Selecting the
Param Set the parameter number and press the INPUT key to move that Parameter Number
No. number to the top and display the parameter. The cursor also moves
to that number.
Area This copies the parameter setting values in the designated range. A 3.8.3 Copying/Pasting
copy The range is designated with numbers. Parameters
This pastes the range of parameters designated in area copy. They A
are pasted in a parameter corresponding to the axis or part system
Area where the cursor is.
paste
Once copied, a parameter can be pasted any number of times until a
new parameter is copied.
This can be selected if the total number of part system display axes is C
Next 5 or more.
axis This is used at the parameter screen with the array structure for each
axis.
This closes the pop-up window and quits this function. C
Close
I - 220
3. Setup Screen
3.8 User Parameters
Operation method (Normal setting: Set "100" for X1 axis of "#8204 OT-" parameter)
(1) Press the Axis param menu. The axis parameter displays.
(2) Use the ↑ , ↓ , |← and →| The cursor moves to the position where the data is to
keys to move the cursor to the setting be set (X1 axis).
position.
(3) Enter a value. The set value displays and the cursor moves one
100 INPUT position downwards.
Operation method (Batch data setting: Set "200" for Y1 axis and "250" for Z1 axis of "#8204 OT-")
(1) Press the Axis param menu. The axis parameter displays.
(2) Use the ↑ , ↓ keys to move the The cursor moves to the position where the data is to
cursor to the setting position. be set.
(3) Enter a value. The set value displays and the cursor moves one
Input format: position downwards.
1st column/2nd column/3rd column
/200 /250 INPUT
(Note 1) When a parameter is changed and PR displays at the top of the screen, reboot the machine
to enable that parameter change.
(Note 2) When the INPUT key is pressed without inputting a value, the parameter setting value is not
changed, and the cursor moves.
(Note 3) Parameters that can be set simultaneously must display within the currently displayed three
columns.
(Note 4) If parameter values are simultaneously input in multiple columns, settings are made from the
currently displayed column on the left side, no matter which column the cursor is positioned.
I - 221
3. Setup Screen
3.8 User Parameters
Operation method (Specifying and copying the parameter where the cursor is located)
(2) Move the cursor to the position of the The copy position displays in the selected area color.
parameter to be copied and press the The menu highlight returns to normal.
INPUT key.
(3) Designate the copy range. The range to be copied displays in the selected area
Format: First No./Last No. color.
8701/8705 INPUT The menu highlight returns to normal.
(Note 1) The selected area color of the copied area returns to normal when the copied data is pasted.
However, the copied range can still be pasted until the parameter type display is changed.
(Note 2) Only the currently displayed parameter type can be copied.
I - 222
3. Setup Screen
3.8 User Parameters
(2) Press the Area paste menu. The menu is highlighted and a confirmation message
displays.
(3) Press the Y or INPUT key. The copied data is written to the parameter where the
cursor is located.
The copied data is not written in when the The menu highlighted returns to normal.
N key is pressed.
(Note) If the relevant parameter is changed after specifying the range to be copied, the value after the
change is pasted.
I - 223
3. Setup Screen
3.8 User Parameters
: Can be used, : Operable under certain conditions (Refer to the section below for conditions.)
Next axis System change Area copy Area paste
Parameter type Parameter No.
menu Key menu menu
(Note 3) (Note 3) (Note 3)
Process parameter 8001 to 8011 -
8041, 8042
8071 to 8075
8701 to 8706
(Note 3) (Note 3) (Note 3)
Fixed cycle 8012 to 8018 -
8051 to 8059
8083 to 8086
Control parameter 8101 to 8124 - - - -
Operation parameter 8501 to 8506 - - - -
I/O parameter 9001 to 9014 - - - -
9101 to 9130
9201 to 9230
9301 to 9330
9401 to 9430
9501 to 9530
Ethernet parameter 9701 to 9706 - - - -
9711 to 9721
9731 to 9741
9751 to 9761
9771 to 9781
Computer link 9601 to 9630 - - - -
parameter
(Note 3) (Note 3) (Note 3)
Subprogram storage 8800 to 8889 -
designation
parameter
(Note 1) (Note 2) (Note 2)
Axis parameter 8201 to 8212 -
(Note 3)
Barrier data (Note 4) 8300 to 8319 -
(Note 3) (Note 3) (Note 3)
High precision 1149, 1150 -
parameter 1205 to 1207
1209
1568 to 1571
8019 to 8023
8025 to 8030
8033 to 8037
8090 to 8094
(Note 2)
High precision axis 2001, 2002 -
(Note 1) (Note 2)
parameter 2010
(Note 1) This is valid only when the total number of valid NC axes and PLC axes in the entire part system
is four or more.
(Note 2) This is valid only when the total number of valid NC axes and PLC axes in the entire part system
is two or more.
(Note 3) This is valid only when the number of valid part systems is two or more.
(Note 4) The barrier data appears only for the L system specifications.
I - 224
3. Setup Screen
3.8 User Parameters
3.8.5 Echoback
When the cursor moves to a parameter with 16 or more characters, all of the set value is echoed back to the
input area. The value of such parameter is displayed with "…" displays in the data field.
Echoback parameters
Parameter type Parameter number, name
Ethernet parameter #9714 Host 1 directory (The same for hosts 2 to 4)
Subprogram storage destination parameter #8881 Subpro stor D0:dir (The same for devices 1 to 4)
I - 225
3. Setup Screen
3.8 User Parameters
Operation method (In the case where the password has not been input even once after turning ON the
power.)
(1) Display the High-accuracy Parameters When the cursor is positioned at the machine
screen. parameters, the "Input a password." message
displays. (System awaits password)
When the ↑, ↓ keys are used to move
the cursor to a position other than the
machine parameters, the awaiting
password status is cleared along with the
message.
(2) Input the machine parameter password "*****" displays at the input area while the password is
and press the INPUT key. being input.
Press the INPUT key to clear the awaiting
password status, and enable machine parameter
settings to be made.
(Note) If the password is input incorrectly, the awaiting password status remains cleared and a "The
password is incorrect." message displays.
I - 226
3. Setup Screen
3.8 User Parameters
I - 227
3. Setup Screen
3.8 User Parameters
<Scaling>
# Item Contents Setting range (unit)
8072 SCALING P Set the scale factor for reduction or magnification 0 to 99.999999
(for M system only) for the machining program for which the G50 or
G51 command is issued.
This parameter is effective when the program
specifies no scale factor.
<Spiral interpolation>
# Item Contents Setting range (unit)
8075 SpiralEndErr Designate the tolerable error range (absolute value) 0 to 99999.999 (mm)
(for M system only) when the end point position commanded with the
command format type 2 spiral interpolation or
conical interpolation command differs from the end
point position obtained from the speed and
increment/decrement amount.
I - 228
3. Setup Screen
3.8 User Parameters
<Coord rotation>
# Item Contents Setting range (unit)
8621 Coord rot plane (H) This sets the plane, center coordinates, vector Axis name
components and angle.
Plane (horizontal axis):
8622 Coord rot plane (V) This sets the name of the 1st axis when measuring
the rotation.
When not set, the name will be the X axis.
Plane (vertical axis):
8623 Coord rot centr (H) -999999.999 to
This sets the name of the 2nd axis when
999999.999 (mm)
measuring the rotation.
When not set, the name will be the Y axis.
8624 Coord rot centr (V)
Plane (vertical) Center
coordi-
nates Vector (vertical)
8625 Coord rot vctr (H) Angle
Center coordi-
nates (vertical) Vector (horizontal)
8626 Coord rot vctr (V)
M Plane (horizontal)
Center coordinates
8627 Coord rot angle (horizontal) -360.000 to 360.000
(°)
(Note) The angle is automatically calculated and
enumerated at vector component setting,
but direct setting of the angle is possible.
When directly setting the angle, "0" appears
in both the horizontal axis and vertical axis
of the vector components.
I - 229
3. Setup Screen
3.8 User Parameters
<TLM>
# Item Contents Setting range (unit)
8701 Tool length This sets the length to the touch tool tip. ±99999.999 (mm)
8702 Tool Dia This sets the diameter of the sphere at the touch ±99999.999 (mm)
tool tip.
8703 OFFSET X This sets the deviation amount (X direction) from ±99999.999 (mm)
the touch tool center to the spindle center.
8704 OFFSET Y This sets the deviation amount (Y direction) from ±99999.999 (mm)
the touch tool center to the spindle center.
8705 RETURN This sets the one-time return distance for 0 to 99999.999 (mm)
contacting again.
8706 FEED This sets the feedrate when contacting again. 1 to 60000 (mm/min)
8707 Skip past amout (H) This sets the difference (horizontal axis direction) of ±99999.999 (mm)
the skip read value and actual skip position.
8708 Skip past amout (V) This sets the difference (vertical axis direction) of ±99999.999 (mm)
the skip read value and actual skip position.
8709 EXT work sign rvs This is set when using the external workpiece 0/1
coordinate system with Z shift.
0: External workpiece offset (Z shift) no sign
reversal (Conventional)
1: External workpiece offset (Z shift) sign reversal
8710 EXT work ofs invld This sets whether external workpiece offset 0/1
subtraction is valid when setting the workpiece
coordinate offset.
0: Do not subtract external workpiece offset.
(Conventional)
1: Subtract the external workpiece offset.
8711 TLM L meas axis This designates the tool length measurement axis. Axis name (Note 1)
This sets the #1022 axname2 axis name.
8712 TLM D meas axis This designates the tool diameter measurement Axis name (Note 2)
axis.
This sets the #1022 axname2 axis name.
(Note 1) If the axis name is illegal or not set, the 3rd axis name will be set as a default.
(Note 2) If the axis name is illegal or not set, the 1st axis name will be set as a default.
I - 230
3. Setup Screen
3.8 User Parameters
I - 231
3. Setup Screen
3.8 User Parameters
I - 232
3. Setup Screen
3.8 User Parameters
I - 233
3. Setup Screen
3.8 User Parameters
I - 234
3. Setup Screen
3.8 User Parameters
8116 Coord rot para invd Select the validity of coordinate rotation by the 0/1
parameters.
0: Valid
1: Invalid
8117 OFS Diam DESIGN Select whether tool radius compensation amount is 0/1
designated with tool radius or tool diameter.
0: Tool radius compensation amount
1: Tool diameter compensation amount
8145 Validate F1 digit Specify whether to execute the F command with a 0/1
1-digit code command or with a direct numerical
command.
0: Direct numerical command (command
feedrate during feed per minute or rotation)
1: 1-digit code command (feedrate specified
with #1185 spd_F1 - #1189 F5)
I - 235
3. Setup Screen
3.8 User Parameters
8906 Counter type 6 This sets the type of counter displayed at the right
of the Manual display on the Monitor screen.
8910 Edit undo This sets whether to validate the Undo function 0/1
during program edit on the Monitor screen or Edit
screen.
0: Invalid
1: Valid
8914 Auto Top search This sets the operation method for restart search 0/1
type 2.
0: It is necessary to set the top search position
arbitrarily.
1: The restart search is executed from O No.
that is designated as head.
8915 Auto backup day 1 When the NC power is ON after the designated -1 to 31
date was passed over, the automatic backup is (-1 can be set for
8916 Auto backup day 2 executed. "Auto backup day 1"
When -1 is set to "Auto backup day 1", the only.)
8917 Auto backup day 3 automatic backup is executed every turning NC
power ON.
8918 Auto backup day 4 When 0 is set to all on "Auto backup day 1" to "4",
the automatic backup is not executed. It is possible
to specify the designated date up to 4 days for a
month.
I - 236
3. Setup Screen
3.8 User Parameters
I - 237
3. Setup Screen
3.8 User Parameters
I - 238
3. Setup Screen
3.8 User Parameters
I - 239
3. Setup Screen
3.8 User Parameters
I - 240
3. Setup Screen
3.8 User Parameters
9712 Host1 user name This sets the user name when logging into the host 15 characters
computer. (alphanumeric) or less
9713 Host1 password This sets the password when logging into the host 15 characters
computer. (alphanumeric) or less
9714 Host1 directory This sets the directory name of the host computer. 31 characters
Refer to (Note 4) for details. (alphanumeric) or less
I - 241
3. Setup Screen
3.8 User Parameters
(Note 1) The user name and password are required when logging in.
(Note 2) It is necessary to enable reading/writing when exchanging files.
(Note 3) With the Personal WEB Server and Windows NT 4.0 fpt Server, the file list format can be selected
from DOS or UNIX.
(Note 4) The directory released to the client (NC unit) with the host computer's server is handled as the root
directory by the NC unit.
I - 242
3. Setup Screen
3.8 User Parameters
9603 PARITY EFFECTIVE This parameter is set when using a parity bit 0: No parity bit used in
separately from the data bit. I/O mode
1 character 1: Parity bit used in I/O
ON mode
OFF b1 b2 b3 b4 b5 b6 bn
I - 243
3. Setup Screen
3.8 User Parameters
I - 244
3. Setup Screen
3.8 User Parameters
I - 245
3. Setup Screen
3.8 User Parameters
I - 246
3. Setup Screen
3.8 User Parameters
I - 247
3. Setup Screen
3.8 User Parameters
I - 248
3. Setup Screen
3.8 User Parameters
After setting up the parameter (PR) listed in the table, turn OFF the NC power. To validate the parameter, turn
ON the power again.
G1bF
G1btL Time
1209 cirdcc Arc Specify the deceleration speed at the arc entrance 1 to 999999 (mm/min)
deceleration or exit.
speed
1568 SfiltG1 G01 software This is a filter time constant used to smoothen 0 to 200 (ms)
acceleration/ changes in the acceleration speed for the cutting
deceleration feed acceleration/deceleration speed when
speed filter accelerating/decelerating before interpolation.
1569 SfiltG0 G00 software This is a filter time constant used to smoothen 0 to 200 (ms)
acceleration/ changes in the acceleration speed for the rapid
deceleration traverse acceleration/deceleration speed when
speed filter accelerating/decelerating before interpolation.
1570 Sfilt2 Software This is a filter time constant used to further 0 to 50 (ms)
acceleration/ smoothen changes in the acceleration speed when
deceleration accelerating/decelerating before interpolation.
speed filter 2 When setting "0" or "1", this parameter is invalid.
1571 SSSdis SSS control The shape recognition range for SSS control is 0/1
adjustment fixed.
coefficient
fixed value
selection
I - 249
3. Setup Screen
3.8 User Parameters
I - 250
3. Setup Screen
3.8 User Parameters
I - 251
3. Setup Screen
3.8 User Parameters
<High-accuracy spline>
# Item Contents Setting range (unit)
8025 SPLINE ON Specify whether to enable the spline function. 0/1
(for M system only) 0: Disable the spline function.
1: Enable the spline function.
Spline interpolation will be valid during G61.2
modal regardless of this setting.
8026 CANCEL ANG. When the angle made by blocks exceeds the set 0 to 180 (°)
(for M system only) value, spline interpolation is canceled temporarily. 0: 180 (°)
In consideration of the pick feed, set a value a little
smaller than the pick feed angle.
8027 Toler-1 Specify the maximum chord error (tolerance) in a 0.000 to 100.000 (mm)
(for M system only) block that includes an inflection point. Set the
tolerance applicable when the applicable block is
developed to fine segments by CAM. (normally
about 10 μm)
When 0.000 is set, the applicable block is linear.
8028 Toler-2 Specify the maximum chord error (tolerance) in a 0.000 to 100.000 (mm)
(for M system only) block that includes no inflection point. Set the
tolerance applicable when the applicable block is
developed to fine segments by CAM. (normally
about 10 μm)
When 0.000 is set, the applicable block is linear.
8029 FairingL Set the length of the block subject to fairing. 0 to 100.000 (mm)
(for M system only) (Valid when "#8033 Fairing ON" is set to 1.)
8030 MINUTE LENGS When the length of one block exceeds the set -1 to 127 (mm)
(for M system only) value, spline interpolation is canceled temporarily 0: 1 (mm)
and linear interpolation is performed. Set a value
a little smaller than one block length of the program.
If - 1 is set, spline interpolation is performed
regardless of block length.
<Fairing>
# Item Contents Setting range (unit)
8033 Fairing ON Set whether to use the fairing function. 0/1
(for M system only) 0: Fairing invalid
1: Fairing valid
Fairing function will be valid during G61.2 modal
regardless of this setting.
8034 AccClamp ON Set the method for clamping the cutting speed. 0/1
(for M system only) 0: Clamp with parameter "#2002 clamp" or the
corner deceleration function.
1: Clamp the cutting speed with acceleration
judgment.
(Valid when "#8033 Fairing ON" is set to 1.)
8036 CordecJudge Change the conditions for judging a corner. 0/1
(for M system only) 0: Judge the corner from the angle of the
neighboring block.
1: Judge the corner from the angle of the
neighboring block, excluding minute blocks.
(Valid when "#8033 Fairing ON" is set to 1.)
8037 CorJudgeL Set the length of the block to be excluded. 0 to 99999.999 (mm)
(for M system only) (Valid when "#8036 CordecJudge" is set to 1.)
I - 252
3. Setup Screen
3.8 User Parameters
<SSS control>
# Item Contents Setting range (unit)
8090 SSS ON Set whether to validate SSS control with G05 0/1
(for M system only) P10000.
0: Invalid
1: Valid
8091 StdLength Adjust the maximum value of the range for 0 to 100.000 (mm)
(for M system only) recognizing the shape.
To eliminate the effect of steps or errors, etc., set a
large value. To enable sufficient deceleration, set a
small value.
If "0.000" is set, the standard value (1.000mm) will
be applied.
8092 ClampCoeff Adjust the clamp speed at the curved section 1 to 100
(for M system only) configured of fine segments.
Coefficient = setting value
8093 StepLeng Set the width of the step at which the speed is not -0.001 to 0.100 (mm)
(for M system only) to be decelerated. (Approximately the same as the
CAM path difference [Tolerance].)
If 0 is set, the standard value (5µm) will be applied.
If a minus value is set, the speed will decelerate at
all minute steps.
8094 DccWaitAdd Set the time to wait for deceleration when the 0 to 100 (ms)
(for M system only) speed FB does not drop to the clamp speed.
I - 253
3. Setup Screen
3.8 User Parameters
I - 254
3. Setup Screen
3.9 MDI Program Editing
Press the main menu [MDI] key to display the contents of the MDI program in a pop-up window.
When the parameter “#1144 mdlkof” is “0” (MDI setting impossible), switch to the MDI mode once to press the
menu “MDI”.
I - 255
3. Setup Screen
3.10 Counter Setting
This function is used to display the relative position counter in a pop-up window and set the counter.
Function : Used to set an arbitrary value in the relative position counter.
Counter display change : The set data displays only at the relative position counter.
Offset : There is no change.
I - 256
3. Setup Screen
3.11 Manual Numerical Value Commands
This function is used to set and display all the Spindle function (S), Miscellaneous function (M), Tool function
(T), and No. 2 miscellaneous function (B) commands.
Input the address for S, M, T, and B to set and display the manual numerical value commands.
Refer to "2.13 Manual Numerical Value Commands" for further details.
I - 257
3. Setup Screen
3.12 T Code List
This function searches the T code in designated machining program (including the subprograms) and lists it
in the order the T codes are commanded. (Max. 100 codes)
As for the T code of the tool that has not been registered, it is indicated with text color and background color
changed.
This window is displayed only when the graphic check option is provided.
(1)
(2)
Display items
I - 258
3. Setup Screen
3.12 T Code List
Memory C
card
C
DS
C
FD
List This updates the list contents. (The latest contents of the currently C
update selected device and directory are listed.)
Sort This changes the method that the list is sorted. C 2.2.3 Changing the
change Sorting Method
This changes whether to show or hide the comment field in the list. B 2.2.2 Changing Whether
Comment
When the comment field is hidden, the file name field will be enlarged. to Show or Hide the
nondisp
Comment Field
This closes the pop-up window and starts getting T codes. C
Retn
(2) Press the menu T-list search . The submenu appears. The list to select a file appears
as a pop-up window.
(3) Select the device. The selected device name and its root directory (HD:/)
[EX.] HD appears in the directory display area.
T code list cannot be displayed when INPUT key is pressed with the following programs selected;
• The program that does not exist.
• The program that is waiting to be restarted.
• The program during automatic operation.
• The program being checked.
The list window will not change.
(Note 1) When switching to the other screen, getting T code is interrupted automatically.
(Note 2) When the Close menu is pressed, getting T code is interrupted automatically.
(Note 3) T code list for MDI program cannot be displayed.
(Note 4) T code list acquisition is not possible for a program with 33 or more program name characters.
I - 259
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
Machining programs can be registered per each pallet of the automatic pallet changer (hereinafter APC) and
the indexing plane.
The Pallet Program Registration screens include "Standard Pallet Registration screen" and "Pallet 4 Page
Registration screen", and those two screens can be switched by the parameters.
Screen Function
Standard Pallet Registration screen Registration of machining programs for pallet 1 & 2 is carried out.
Pallet 1 & 2 can be registered at once.
Pallet 4 Page Pallet list Machining program device, file name, machining status, and index
Registration screen planes under machining for 4 planes of the pallet 1 to 12 are
screen displayed.
Information of 2 pallets can be displayed at once.
Pallet details Machining program device, file name, machining status, and
screen external workpiece coordinates for each plane of the pallet 1 to 12
are set.
Information of one pallet's 2 indexing planes can be set at once.
(Note) The number of pallets is determined by the parameter "#11002 Valid pallet num".
Inputting an address key, such as MST, displays manual numerical value command window where manual
numerical value command is executed.
I - 260
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
(1)
(6)
(2)
(3)
(4)
(5)
Display items
I - 261
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
Menus
File The file name to be registered can be selected from the list. C Selecting a file name
set A list of files of the currently selected device is displayed. from the list
This menu can be used only when the cursor is at file name.
The state (Machining, Program Search, Program Start) indicated by C Registering a machining
ON the cursor is validated. program for the pallet
This menu can be used only when the cursor is at Machining,
Program Search, or Program Start.
The state (Machining, Program Search, Program Start) indicated by C
OFF the cursor is invalidated.
This menu can be used only when the cursor is at Machining,
Program Search, or Program Start.
(2) Press the Device select menu and The cursor is moved to "Device". The device menu
select a device. (Memory, HD, DS, FD, Memory card) is displayed. If
selected, the device selected in "Device" is displayed.
(3) Move the cursor to "File name" and input The contents set in "File name" is displayed.
the program No.
Move the cursor to "Machining" and press The contents set in "Machining" is displayed.
(4) the ON or OFF menu.
(5) Move the cursor to "Program Search" and The contents set in "Program Search" is displayed.
press the ON or OFF menu.
(6) Move the cursor to "Program Start" and The contents set in "Program Start" is displayed.
press the ON or OFF menu.
(1) Move the cursor to "File name" and press A list of files for the specified device is displayed.
the File set menu.
(2) Move the cursor to an arbitrary file and The selected file name is displayed in "File name". The
press the INPUT key. cursor is moved to "Machining". An arbitrary file name
can be directly entered, as well.
(Note 1) When a file name is directly entered, whether or not the file exists is not checked.
(Note 2) When a file name is directly entered, if other than character strings or values within the setting
range (1 to 99,999,999) is set, an error occurs.
(Note 3) If a directory is specified, a setting error occurs.
I - 262
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
Machining program device, file name, machining status, and index planes under machining for 4 planes of
the pallet 1 to 12 are displayed.
(Note) The number of pallets is determined by the parameter "#11002 Valid pallet num".
(1)
(2)
(6)
(3)
(4)
(5)
Display items
I - 263
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
Menus
Pallet The screen is shifted to the Pallet details screen. B 3.13.3 Pallet Details
details The 0° or 90° data of the pallet displayed on the top line of the Pallet Screen
list screen is displayed.
(1) When the pallet 1 and 2 are displayed, Pallet 3 and 4 are displayed.
press the Next pallet menu or next
page key.
(2) Press the Prev pallet menu or previous Pallet 1 and 2 are displayed.
page key.
(1) Using the , , , keys, The contents set in "Program Search" is displayed.
move the cursor to "Program Search" and The cursor moves to "Program Start".
press the ON or OFF menu.
(1) Using the , , , keys, The contents set in "Program Start" is displayed. The
move the cursor to "Program Start" and cursor moves to "Program Search".
press the ON or OFF menu.
Every time the , , , or key is pressed, the cursor switches between "Program Search"
and "Program Start".
I - 264
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
Machining program device, file name, machining status, Aux. and external workpiece coordinates for each
plane of the pallet 1 to 12 are set.
(Note) The number of pallets is determined by the parameter "#11002 Valid pallet num".
(5)
(1)
(6)
(2)
(3)
(4)
Display items
I - 265
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
(Note 1) The operation message "Pallet running" appears when the setting of "Program Dev.", "Program
Name", "Machining", or "Aux." is executed to the index plane under machining of a pallet in
machine. The "Program Dev.", "Program Name", "Machining", or "Aux." can be set when the
index plane of a pallet in machine is not under machining.
Even if the index plane of a pallet in machine is under machining, the external workpiece
coordinate can be set.
Menus
File File name to be registered can be selected from a list. C 3.13.1 Standard Pallet
set A list of files of the currently selected device is displayed. Registration (Selecting a
When the cursor is pointing at file name, this menu is operatable. file from the list)
ON The state (Machining) indicated by the cursor is validated. C Setting values in each
This menu can be used only when the cursor is at Machining. index plane
OFF The state (Machining) indicated by the cursor is invalidated. C
This menu can be used only when the cursor is at Machining.
Previous index plane is displayed. C Changing index planes
When 0° or 90° index plane is being displayed, this menu displays the
Prev previous pallet, 180° or 270° index plane. When 180° or 270° index
plane plane is being displayed, this menu displays 0° or 90° index plane.
When 0° or 90° index plane of the pallet 1 is displayed, this menu
cannot be selected.
Next index plane is displayed. C
When 0° or 90° index plane is being displayed, this menu displays
Next 180° or 270° index plane. When 180° or 270° index plane is being
plane displayed, this menu displays the next pallet, 0° or 90° index plane.
When 180° or 270° index plane of the last pallet is displayed, this
menu cannot be selected.
An arbitrary pallet can be selected. A Changing display pallets
Pallet When the pallet No. is set and the INPUT key is pressed, the 0° or 90°
select pallet details data for that pallet will be displayed. The cursor will move
to the 0° machining program file name.
The Pallet list screen will open. B 3.13.1 Standard Pallet
Pallet
list A list of pallets, including the pallet displayed on the Pallet details Registration
screen will appear.
Pallet This displays the pallet details. B
details
I - 266
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
(1) Press the Pallet select menu. Input The pallet 5's 0° and 90° index plane will appear.
pallet No. and press the INPUT key.
5 INPUT
(Example) When the screen display status acquired after the above (Changing display pallets) operation
(1) Press the Next plane menu or next The pallet 5's 180° and 270° index plane will appear.
page key.
(2) Press the Prev plane or previous page The pallet 5's 0° and 90° index plane will appear.
key.
I - 267
3. Setup Screen
3.13 Pallet Program Registration [700 series only]
(2) Press the Device select menu and The cursor moves to "Device". The device menu
select a device. (Memory, HD, DS, FD, Memory card) is displayed. If
selected, the device selected in "Device" is displayed.
After setting, the cursor moves to "File name".
(3) Enter program No. in "File name". Contents set in "File name" is displayed. The cursor
moves to "Machining".
A file can be selected from the list, as well.
(4) Press the ON or OFF menu for The contents set in "Machining" is displayed.
"Machining". The cursor moves down.
(5) Move the cursor to "Ext coord" and input Values for 3 axes are set. The cursor moves to the
values for 3 axes. "Program File name" above.
I - 268
4. Edit Screens
4.1 Screen Configuration
4. Edit Screen
The Edit screen is used to edit the machining program (adding, erasing and changing), perform checks, and
input/output data.
Left Right
area area
I - 269
4. Edit Screens
4.1 Screen Configuration
Menus
I - 270
4. Edit Screens
4.2 Program Editing
This is used to edit (add, erase, change) the machining programs in the NC memory, HD, memory card
(front IC card), DS (compact flash) or FD, and to create new programs.
(In 70 series, only the memory and the memory card can be used.)
This function is used for three types of program: machining program, MDI program and fixed cycle program.
Press the main menu Edit key to display the program found when performing an operation search (MDI
program in MDI mode).
The contents of the left area depends on the display type:
Check display type :Enables to edit a program confirming the program check screen.
Multi-program display type :Enables to edit two programs using left and right editing areas.
G-code guidance display type :Enables to edit a program referring to the G code guidance.
Playback display type :Enables to edit program trying sample machining.
There are two types of editing available: regular editing and mass-editing. The specification and the
limitation are different between regular editing and mass-editing.
The conditions and the maximum edit size of mass-editing are as follows.
(1)
(3)
(2)
(4)
(5)
I - 271
4. Edit Screens
4.2 Program Editing
Display items
Menus
I - 272
4. Edit Screens
4.2 Program Editing
Line This inserts the copied line at the line before the cursor. C
paste This menu cannot be selected during mass-editing.
Line This erases the designated line (multiple lines can be erased.) A 4.2.11 Deleting Data
clear This menu cannot be selected during mass-editing.
This returns the contents of the program to that prior to saving and C 4.2.15 Undoing Program
display. Changes
Undo This menu cannot be selected when parameter "#8910 Edit Undo" is
set to "0".
This menu cannot be selected during mass-editing.
In 70 series, this menu cannot be selected.
Display This switches the display type. C
change
Comment This changes whether to show or hide the comment field in the list. B
nondisp When the comment field is hidden, the file name field will be enlarged.
When the character string is designated and the INPUT key is A 4.2.12 Searching for
String Character Strings
search pressed, that character string is searched for.
This menu cannot be selected during mass-editing.
If the character string to be searched for and the character string to A 4.2.13 Replacing
String be replaced are separated with a "/" and designated, when the Character Strings
replace INPUT key is pressed, the character string is replaced.
This menu cannot be selected during mass-editing.
This enables the input mistake check for the program being edited. B 4.2.16 Correcting/
Miss This menu cannot be selected during mass-editing. Displaying Input
warning
This menu is only for 700 series. Mistakes
This moves the cursor to the next input mistake warning location. C
Next This menu cannot be selected during mass-editing.
miss
This menu is only for 700 series.
The sequence No. can be added automatically by pressing the A 4.2.17 Adding Sequence
N auto INPUT key after designating an additional value. No. (N No.)
add
This menu cannot be selected during mass-editing. Automatically
MDI This registers the MDI program in the memory. A 4.2.3 Editing MDI
regist This can be performed only when the MDI program is displayed. Program
This deletes the programs. When the name of the program to be A 4.2.5 Deleting a File
Erase erased is designated and the INPUT key is pressed, the
file
designated file is deleted.
I - 273
4. Edit Screens
4.2 Program Editing
Operation method
(1) Press the menu Open (New) . The following menu appears.
The list appears as a pop-up window.
(2) Select a device. The selected device name and directory (Memory:
(Ex.) Menu Memory /Program) appear in the Device name, Directory
display column.
For the devices other than memory, root directory is
selected.
(3) Input the file name for the program to be If a program can be newly created, a program
newly created and press the INPUT containing only EOR is created.
key. The list display is closed.
(Ex.) 100 INPUT
(4) Edit a machining program. Refer to "4.2.6 Edit Operations" and later.
(5) Press the INPUT key. The created machining program is saved to the
device.
I - 274
4. Edit Screens
4.2 Program Editing
Operation method
(2) Select a device. The selected device name and directory (memory:
(Ex.) Menu Memory /program) appear in the Device name, Directory
display column.
For the devices other than memory, root directory is
selected.
(4) Press the INPUT key. The program appears at the top if the file can be
opened.
The cursor moves to the head character of the
program. The mode enters the overwrite mode.
The list display is closed.
(5) Edit a machining program. Refer to "4.2.6 Edit Operations" and later.
(6) Press the INPUT key. The edited machining program is saved to the device.
I - 275
4. Edit Screens
4.2 Program Editing
Operation method
(2) Edit the MDI program. Refer to "4.2.6 Edit Operations" and later.
(Note 1) Before starting MDI operation, confirm that the MDI settings are completed. If "Editing" or "MDI
no setting" is displayed, the MDI operation cannot be started.
When the INPUT key is pressed, the head block will be searched, and the message "MDI
search complete" will appear. The setting will then be completed.
If the cursor is moved without editing, the block indicated by the cursor will be searched for
when the INPUT key is pressed.
(Note 2) If the INPUT key is pressed when the number of MDI program characters including EOB (;)
and EOR (%) exceeds 2000, "Memory capacity over" message will appear and the MDI
program will not be searched for execution.
Note that the contents edited after the MDI program is saved last will not be saved in the NC
memory.
Operation method
(1) Press the menu MDI regist . The menu is highlighted and turned to the program
No. input wait status.
The cursor appears in the input area.
(2) Set the program No. to be registered and MDI program is registered in the memory. The
press the INPUT key. operation message "MDI entry complete" is displayed.
The menu highlight returns to normal. The cursor
returns to the program display area.
(Note 1) When the INPUT key is pressed without entering the program name, a setting error occurs.
(Note 2) When the entered program name already exists in the NC memory, the operation message
"Overwrite this file?(Y/N)" is displayed.
(Note 3) MDI programs cannot be registered in the NC memory in the following cases.
• When the setting is made for other than programs with the parameter "#1166 fixpro".
• During "Editing" is displayed.
• When the remaining size of program is smaller than the MDI program to be registered.
• When the remaining number of programs that can be registered is "0".
• Entered program name already exists in the NC memory, and the status is in automatic
operation or program restarting.
I - 276
4. Edit Screens
4.2 Program Editing
Operation method
(1) Press the menu Erase file . The following menu appears.
The list appears as a pop-up window.
(2) Select a device. The selected device name and directory (memory:
(Ex.) Menu Memory /program) appear in the Device name, Directory
display column.
For the devices other than memory, root directory is
selected.
(4) Press the INPUT key. The operation message "Erase? (Y/N)" appears.
! CAUTION
If "there is no value after the G" command, the operation will be the "G00" operation when the
program is run due to key chattering, etc., during editing.
I - 277
4. Edit Screens
4.2 Program Editing
Switching the active area is possible only when the multi-program display type is selected.
Press the <--> change key to switch the active area between the left and right window.
Right side is active (can be edited) Left side is active (can be edited)
<--> change
Changing the display using the page changeover keys ( : Previous Page, : Next Page)
key: This displays one page of preceding lines of the current top line.
When there is less than one page of data, a page of data will be displayed including the data
currently displayed.
(The cursor moves to the last line of the screen. Cursor does not move in mass-editing.)
key: This displays one page of following lines of the current bottom line. (The cursor moves to the top
line of the screen. Cursor does not move in mass-editing.)
The cursor will move up one line in the program each time the cursor key ( , ) is pressed.
If the key is pressed at the top line of the program display area, the program will scroll up one line.
If the key is pressed at the end, the program will scroll down one line.
When a block is displayed over 2 or more lines, , keys move the cursor by block unit during regular
editing and by line unit during mass-editing.
↓
11:N11;
↑ 12:N12 Z300.; ↓
13:Y200.;
14:;
Display scrolls without
moving cursor position.
I - 278
4. Edit Screens
4.2 Program Editing
Move the cursor using the tab keys ( |← : back tab/ →| : tab).
|← key : Moves to the start of the word where the cursor is currently positioned.
If the cursor is at the start of a word, it moves to the start of the previous word.
→| key : Moves to the word after the word where the cursor is currently positioned.
(Note) Pressing |← →| keys or ← → keys does not make any difference in mass-editing.
Operation method
(2) Input the line No. The program appears with the set line No. at the
(Ex.) 6 INPUT head.
The cursor moves to the head.
The menu highlight returns to normal.
(Note 1) When "0" is input, the cursor moves to the first line.
(Note 2) When "E" is input, the cursor moves to the end.
I - 279
4. Edit Screens
4.2 Program Editing
Operation method
(2) Set the data. The message "Editing" appears when setting is
started.
The data is set from the position of the cursor. Data at
the area is overwritten.
The cursor moves one space (character) at a time to
the right as the data is set.
(3) When one line of setting is completed, EOB ( ; ) is added to the set data and the data is fixed.
press the INPUT key. When newly creating data, the cursor moves to the
head of the next line.
When changing existing data, etc., the cursor does
not move.
(Note 1) Up to 255 characters can be input in one block in regular editing and 127 characters in mass-
editing.
(Note 2) When the cursor is on or one place to the right of EOB ( ; ), input data is inserted even if not in
input mode (refer to "4.2.10 Inserting Data".)
(Note 3) When changing to another function such as the program check, or to another screen such as
the operation screen when "Editing" displays, the operation message "Save current file? (Y/N)"
displays. If N key is pressed changing to the other screen once, and the Edit screen is
selected again, the program before editing operation will be displayed. (Edited contents will be
invalid.)
(Note 4) "Saving" is displayed in flickering during saving.
I - 280
4. Edit Screens
4.2 Program Editing
Operation method
(3) Set the data. The data is inserted before the cursor position. Data
after the cursor moves to the night.
(4) When the setting is completed, press the The set data is fixed.
INPUT key. The cursor does not move, but if there is no EOB ( ; )
at the end of the line, it will be added. Then, the cursor
moves to the next line.
The mode returns to the overwrite mode, and the
message "Editing" disappears.
I - 281
4. Edit Screens
4.2 Program Editing
(2) Press the DELETE key. 1 character is deleted at the cursor position, and
"Editing" appears. The data from the cursor position
moves to the left.
When this key is held down, the characters can be
deleted one at a time.
(3) Press the INPUT key. The edited machining program is saved to the device
and "Editing" disappears.
(2) Press the C.B key. 1 line is deleted at the cursor position, and "Editing"
appears. The lines following the cursor position are
shifted upward. The cursor position does not change.
When this key is held down, the line can be deleted
one at a time.
(3) Press the INPUT key. The edited machining program is saved to the device
and "Editing" disappears.
(Note 1) In the case where the block for the deleted line covers multiple lines, these lines are also
deleted.
(Note 2) Last line only with "%" cannot be deleted.
I - 282
4. Edit Screens
4.2 Program Editing
(2) Designate the deletion range. The background color for the range to be deleted
(Ex.) From line 8 to line 10 turns light blue.
8/10 INPUT The message "Erase? (Y/N) " appears.
(3) Press the Y or INPUT key. The data in the range with the blue background is
deleted and the menu highlight returns to normal.
Press the N key not to delete. The lines following the deleted data are shifted
upward.
The cursor position and top line No. do not change.
(Note 1) If the INPUT key is pressed without setting a line No., the line where the cursor is will be
deleted.
(Note 2) If the last line of the file is the range to be deleted, the last line can be designated as "E".
(Example) From 8th line to last line : 8/E
From 1st line to last line: /E
(Note 3) Mass-editing has restrictions below.
• The range has to be within 100 lines.
• Last line designation switch "/E" is invalid.
(Note 4) "Executing" is displayed in flickering during line clear.
Operation method (Deleting several lines (one screen of data) displayed on a screen)
(1) Press the CAN key. Data (machining program) for 1 screen is deleted, and
"Editing" appears.
(2) Press the INPUT key. The edited machining program is saved to the device
and "Editing" disappears.
I - 283
4. Edit Screens
4.2 Program Editing
Operation method
(2) Set the character string to be searched A search for a character string is made from the
for, and press the INPUT key. character after the cursor position downwards.
If the character string is discovered, the cursor moves
(Ex.) G20 INPUT
to the start of that character string.
A message appears if there is no character string
applicable to the program.
Marking can be performed by adding an option to the
character string being searched for.
((Ex.) G20/MR :G20 are marked in red.
(Refer to the "Marking function" for further details.)
(3) To continue searching, press the INPUT The next corresponding character string is searched
key again. for.
The search finishes when the end of the program is
reached.
(Note) It is not possible to return to the head of the
program and resume the search. To search
from the head of the program, move the
cursor to the top line and carry out the search
operation again.
(4) To end the search, press the menu key. The menu highlight returns to normal, and the
character string in the input area disappears.
The search mode is held until the menu key is
pressed.
(The character string remains in the input area.)
I - 284
4. Edit Screens
4.2 Program Editing
Marking function
Marking can be performed by adding an option to the character string being searched for.
(Note 1) The marking status is maintained when another program is opened while character strings are
still marked.
(Note 2) If the input mistake check warning function is enabled while character strings are still marked,
the marking is given priority in the case where the input mistake location and the marked
display overlap.
(Note 3) In the case where the search marking and input mistake check warning function are displayed
simultaneously, the marking is cleared and the input mistake warning display remains.
(Note 4) With the multi-program display type, the search and marking is valid only in the area where the
search and marking is carried out.
(Note 5) The marked status is maintained until the NC power is turned OFF.
(Note 6) Marking function is invalid in mass-editing.
(1) If the designated character string cannot be found, a "Designated character string not found" message
displays.
(2) A search is performed for a character string containing the designated character string, irrespective of
the characters before and after. As a result, if "G2" is designated, G20 - G29 and G200 etc. will also
be the subject of a search.
I - 285
4. Edit Screens
4.2 Program Editing
Operation method
(2) Designate the search character string and The character string is searched downward from the
the replace character string. character after the current cursor position.
((Ex.) Search character string: G02 If a character string is discovered, the cursor moves to
Replace character string: In the the start of that character string, and a "Replace?
case of G03 (Y/N) " message appears.
G02/G03 INPUT (Note 1) If any character string is not found in the program, the
cursor does not move.
(3) Press the Y or INPUT key. The character string is replaced, and a search is
performed for the next applicable character string. (If a
Press the N key not to replace. batch replacement is performed, a search is not made
as the replace has been completed.)
A "Designated character string not found" message
appears when the end of the program is reached.
"Editing" appears if replace is performed.
(4) Press the Y or INPUT key again if The same operation as above is performed.
continuing the search/replace.
(5) To end search/replace, press the The menu highlight returns to normal, and the
String replace . character string in the input area disappears.
The replacement mode is held until the menu key is
pressed.
(The character string remains in the setting area.)
(Note 1) When batch replacing for all the character strings in the program, add "/G" to the above setting.
Search character string/replace character string/G (Ex.) G02/G03/G
During batch replacement, after replacing all character strings to the end of the program, the
process ends while showing the last character string replaced. Note that the replacement mode
is held, and the character string remains in the input area.
(Note 2) If the program character strings from the current cursor position to the last line are to be
replaced in a batch, add "/E" to the above setting.
Search character string/replace character string/E (Ex.) G02/G03/E
(Note 3) "Executing" is displayed in flickering during string replace.
I - 286
4. Edit Screens
4.2 Program Editing
(2) Designate the range to be copied. The background color for the range to be copied turns
(Ex.) From line 8 to line 10 light blue.
8/10 INPUT The menu highlight returns to normal.
(1) If INPUT key is input without setting a line No., the line where the cursor is at is copied.
(2) The highlight of the copy target lines disappears when editing operations are resumed.
(3) If the file is edited after the Line copy menu is pressed, the data copied in the line is canceled.
(4) If the last line of the file is the range to be copied, the last line can be designated as "E".
(Example) From 8th line to last line : 8/E
(5) The copied data is maintained while the copy source file is opened even if the display type or editing
area is switched to another one.
(6) Up to100 lines can be copied in mass-editing.
(2) Press the Line paste menu. The copied data is inserted in the line before the
cursor position, and "Editing" appears.
(3) Press the INPUT key. The edited machining program is saved to device, and
"Editing" disappears.
(Note 1) With multi-program display type, data can be copied and pasted between both left and right
areas.
(Note 2) Copy/past is not possible in between regular editing and mass-editing.
(Note 3) "Executing" is displayed in flickering during line paste.
I - 287
4. Edit Screens
4.2 Program Editing
(1) Change to memory mode and press the The searched program appears from the top.
main menu Edit key.
(2) Move the cursor to the position to be The data is replaced with input data and " Editing"
corrected, and input a character. appears.
(Ex.) 135
(3) Press the INPUT key. The edited machining program is saved to the device
and "Editing" disappears.
(4) Press the menu Undo . The contents of the file return to the same condition
as when the editing was started in the procedure (1).
These contents of the file are saved to the device.
(5) Press the menu Undo again. The contents of the file return to the same condition
as when the file was saved in the procedure (3).
These contents of the file are saved to the device.
(Note1) This function is only valid when parameter "#8910 Edit Undo" is set to "1".
(Note2) When returned to the previous status, the cursor will move to the head line.
(Note3) With the multi-program display type, returning to the previous contents is valid only in the active
area.
(Note 4) Undoing is not possible in mass-editing mode.
(Note 5) "Executing" is displayed in flickering during undoing.
I - 288
4. Edit Screens
4.2 Program Editing
I - 289
4. Edit Screens
4.2 Program Editing
I - 290
4. Edit Screens
4.2 Program Editing
I - 291
4. Edit Screens
4.2 Program Editing
(1) Press the menu Open (New) , input a Only an EOR program is created.
new file name, and press the INPUT
key.
(3) Edit the program. A warning is displayed at the moment the INPUT
key is pressed.
I - 292
4. Edit Screens
4.2 Program Editing
(2) Press the Edit menu. Machining programs appear from the top.
(3) Press the Miss warning menu. A warning displays the position where an input
mistake occurred. The cursor moves from its current
position to the first input mistake that was found.
(4) Press the Next miss menu. The cursor moves to the next input mistake position.
I - 293
4. Edit Screens
4.2 Program Editing
Precautions
(1) The input mistake check timing is outlined in the following table.
If the Miss warning menu is pressed again when the input mistake check warning function is enabled,
this function is then disabled.
The character color of the location of an input mistake then returns to normal.
(2) The Next miss menu is grayed out and cannot be selected when the Miss warning menu is not
highlighted.
(3) An input mistake check warning function can be performed even when editing a MDI program.
(4) An input mistake check warning function can also be performed for a comment block.
(5) If the data in an address that is subject to a decimal point input mistake is "0", no warning is issued
regardless of the presence of a decimal point.
((Ex.) No warning is issued for "X0")
If the data in an address that is subject to a decimal point input mistake has been omitted, no warning is
issued.
((Ex.) No warning is issued for "G28XYZ")
(6) Blocks with " [","]" are not subject to an input mistake check warning function.
(7) The input mistake status is held in the operation screen edit window, setup screen MDI edit window, and
edit screen edit area.
(8) If an input mistake is found after the current cursor position, the "Input miss was detected" message
appears. If no input mistake is found, the "Input miss was not detected" message appears.
(9) With the multi-program display type, the input mistake check is performed also in the non-active area.
Note that the messages “Input miss was detected" and "Input miss was not detected" will be displayed
by judging the input mistake referring to the cursor position in the active area.
(10) Input mistake check warning function is disabled in mass-editing.
(11) "Executing" is displayed in flickering during checking input mistakes.
I - 294
4. Edit Screens
4.2 Program Editing
When the sequence No. (N No.) is input once, the sequence No. to which a constant value is added can be
automatically added to each block of the machining program.
The added sequence No. data is to N2 to N999999.
This function is disabled during mass-editing.
Operation method
(1) Press the menu N auto add. The menu key is highlighted and turned to the
additional value input wait status. The cursor appears
in the input area.
(2) Input the additional value. "N+10" is displayed in N No. additional value display
(Ex.) 10 INPUT column. The cursor moves from the input area to the
edit area.
(4) Input a file name not used, then press the "O100" is created in edit area.
INPUT key.
(Ex.) 100
(4) Select a file, then press the INPUT key. The selected file is opened in edit area.
(6) Input " ; " (EOB). "N110" (previous block N No. "N100" + an additional
value "10") is added after a " ; " (EOB).
I - 295
4. Edit Screens
4.2 Program Editing
(7) Input the second block data and " ; " "N120" is added behind " ; ".
(EOB).
(Ex.) G92X0.Y0.Z0.;
(8) Press the INPUT key. The message "Editing" disappears. The program
is saved.
(Note 1) When the menu N auto add is pressed again while the menu is highlighting, N No. additional
value display column is cleared, and N No. automatic addition is canceled.
(Note 2) The setting range is 1 to 1000. When "01" is input, "1" is set. When "0" is input, this function is
canceled. When an illegal value or 9 characters or more is input, an error will occur.
(Note 3) The additional value can be set even when the machining program has been not opened. Even
if the machining program is opened again, the additional value is not invalid.
(Note 4) This function is enabled only during regular editing of edit screen.
(Note 5) This function is disabled during mass-editing. However, the set N No. additional value in regular
editing is not cleared, and the additional value is valid during regular editing again.
(Note 6) Even if the same N No. exists by automatic addition, an error will not occur.
(Note 7) The system separately has N No. in a right area and left area of the edit screen.
(Note 8) When the previous block is leading zero like "N010", N No. automatic addition can be executed.
However, "0" is not added, and "N10" is displayed.
I - 296
4. Edit Screens
4.2 Program Editing
(1) When the previous block has N No. (When the cursor is located at the last character in the overwrite
mode.)
N100 G28 X0 Y0 Z0 ; -> Input ";" -> N100 G28 X0 Y0 Z0;N110;
N100 G28 X0 Y0 Z0 ; -> Input ";" -> N100 G28 X0 Y0 Z0 ;N110;
N100 G28 X0 Y0 Z0 ; -> Input ";" -> N100 G28 X0 Y0 Z0 ;N110;
(2) When the previous block has N No. (When the insertion mode)
N100 G2 8 X0 Y0 Z0 ; -> Input ";"-> N100 G2;N110 8 X0 Y0 Z0 ;
N100G28X0Y0Z0; N200G90X20.Y20.Z20.;
-> Input ";"-> N100G28X0Y0Z0;N110 N200G90X20.Y20.Z20.;
I - 297
4. Edit Screens
4.2 Program Editing
The contents displayed on the G code guidance area depends on the cursor position on the Edit screen, and
is refreshed when moving the cursor.
The G code that meets following conditions are displayed in this area.
• G code that exists between the head of block and cursor position including the cursor position.
• G code that exists immediately before the cursor if multiple G codes meet the above condition.
Specific example
G91 G17 ; The guidance will not be refreshed because the cursor
is out of the block.
G91 G00 X100. Y100. ; The guidance for G00 will be displayed because G00
is the nearest G code to the cursor.
I - 298
4. Edit Screens
4.2 Program Editing
With G code guidance function, the commands having "G" followed by 1 or more numbers are regarded as
the G code. Thus, when "G" that is located immediately before the cursor is within the comment, the
guidance will not be refreshed. In the same manner, when a G code is commanded using variables such as
"G#100" or "G#500", etc. but numbers, the guidance will not be refreshed.
The G code that can be displayed in the guidance area is as follows.
G91 G120 X100. Y100. ; G code "G120" is not included in the specifications,
thus, G code guidance will not be refreshed.
L50 G10 ; The guidance not for "G10 L50" but "G10" will be
displayed.
I - 299
4. Edit Screens
4.2 Program Editing
(1) G code guidance may be refreshed when the cursor is located near the comment.
[Ex.] ( PROG01 ) ; The guidance for G01 will be displayed.
(2) When the cursor is located at the axis address, etc., the guidance for the nearest G code will be
displayed even if the address has no relationship with the G code.
[Ex.] G01 G90 X100. ; G code that has a relationship with "X100. " is "G01",
however, G code guidance for "G90" will be displayed.
(3) When moving the cursor to the block with no G code as follows, the contents of guidance will differ
depending on the cursor’s route even if the cursor is in the same block.
[Ex.] N01 G91 G01 X100. F1000 ; When the cursor is moved by the route "a", the
guidance for G01 which is displayed last in N01 block
↓ will also be displayed in N02 block.
N02 Y100. Z100. ; ← ... a When the cursor is moved by the route "b", the
guidance for G02 which is displayed last in N03 block
↑b
will also be displayed in N02 block.
N03 G02 X50. Y50. R50. ;
(4) G code guidance will be refreshed even if an option of the G code is not valid. Thus, G code could not
function though the guidance is displayed.
(5) Basically, G code format in the guidance is displayed using the format of 3-axis specifications of X, Y,
and Z.
(6) Whichever plane is selected among the plane selection functions G17 to G19, the display data in the
guidance is displayed using X-Y plane (G17) format.
(7) When the G code command includes an address which have two or more meanings, both contents will
be displayed.
(8) G code guidance will not be refreshed while the character string is searched or replaced.
I - 300
4. Edit Screens
4.2 Program Editing
(1)
(2)
(3)
(1)
(2)
(3)
I - 301
4. Edit Screens
4.2 Program Editing
Display items
I - 302
4. Edit Screens
4.2 Program Editing
(1) Set "#1126 PB_G90" to "0" on the Incremental value mode is set.
parameter screen.
(2) The menu Display change or key is The "playback display type" is displayed.
press several times on the edit screen. The menu <--> change cannot be used.
(3) Open the program pressing Edit and The selected program is displayed in right area.
Open on the edit screen.
(4) Move the axis during manual mode. The axis movement amount is displayed in playback
movement amount.
I - 303
4. Edit Screens
4.2 Program Editing
(5) Input the data such as the G codes in the The alphanumeric characters, ←, → and DELETE
area for playback editing.
keys can be input in the area for playback editing.
(6) Press the axis address key such as X or The playback movement amount is input after the axis
Y. address in the playback editing area. If the axis
address key is pressed while the playback movement
amount is being changed, the playback movement
amount at the time the key was pressed will be input.
(7) Press the INPUT key. The program in the playback editing area will be
inserted at the block before the cursor position in the
right area, and the program is saved.
When there is no "EOB" (;) at the end of the character
string, it is added automatically.
The cursor moves to the line head being cleared the
content of the playback edit.
For an absolute value, the playback movement
amount will not change.
For an incremental value, the difference of the axis
command value for the axis used in step (6) and the
playback movement amount will remain as the
playback movement amount.
(Note) If the program is not displayed on right area,
the operation message "Can't execute
playback edit" appears.
(Note 1) When the program is not displayed on the right area, a playback editing cannot be executed.
(Note 2) When the C.B key is pressed, all data in the playback editing area will be erased.
(Note 3) When the and keys are pressed, the program cursor on the right area will move.
(Note 4) When the page-switching key is pressed, the program on the right area will scroll.
(Note 5) When the menu key is pressed, the process corresponding to the right area will run.
I - 304
4. Edit Screens
4.2 Program Editing
(1) Playback editing of a program in automatic operation or program restart is not possible.
(2) Up to 95 characters can be edited in the playback editing area.
(3) If the screen/part system is changed or the program file is opened when the input program is in the
playback edit area, the program being edited will be aborted.
(4) Other files can be opened during playback editing. Playback editing can be continued even when other
file is opened. However, if an incremental value is designated, the playback movement amount will be
cleared to 0 for all axes. A new file can be created and edited, and MDI editing carried out in the same
manner.
(5) If the program being playback edited automatically starts, playback editing cannot be continued.
(6) The playback movement amount after playback editing will differ according to the parameter "#1126
PB_G90" state and the commanded G code. The playback movement amount after INPUT is pressed is
calculated for each block that has been playback edited.
X axis playback X axis playback movement amount after INPUT
Details to be
movement
playback
amount before For an absolute value For an incremental value
edited
editing
X 100.000 G01 X10.; X 100.000 X 90.000
The program position + The difference of the axis
manual interrupt amount is command value (X10.) and
inserted as the playback playback movement amount
movement amount. before INPUT (X100.) is
inserted as the playback
movement amount.
G92 X10.; X 10.000 X 0.000
The command value (X10.) Regardless of the command
following G92 is inserted as value following G92, 0 is
the playback movement inserted as the playback
amount. movement amount.
(7) The playback editing is disabled during mass-editing.
(8) Do not set the same address to the parameter "#1013 axname" and "#1014 incax". If the same address
is set, the absolute counter has priority. (However, the same address as the address used in other part
system can be specified.)
I - 305
4. Edit Screen
4.3 Program Check (2D)
The program check function (2D) is used to graphically draw the machining program movement path without
performing auto operation.
The machining program can be checked with graphic data drawn at a high speed.
Using All display menu, normal display and full-screen display modes can be switched.
(Note1) The program check (2D) function is an additional specification. The graphic check option is required.
(Note2) When changing the screen to the edit screen, display depends on the previous checking type
(2D/3D). Note that when selecting this screen during graphic trace, 3D solid program check will apply.
If the 3D solid check option is not valid in this time, the area of “Check” tag will not be blank.
(8)
(1)
(9)
(2)
(3)
(4)
(5)
(6)
< Drawing area: 2-plane > < Input area displayed >
(7)
I - 306
4. Edit Screen
4.3 Program Check (2D)
(1)
(3) (5)
(8)
(9)
(2)
(6) (4)
Display items
I - 307
4. Edit Screen
4.3 Program Check (2D)
Menus
(Note) The menu 3D check and Operate search keys cannot be selected while the check is performed or
interrupted. Menu can be selected after Check reset is pressed.
I - 308
4. Edit Screen
4.3 Program Check (2D)
Operation method
(1) Press the main menu Check . The program check screen becomes active.
(2) Press the Operate search key. The following menu appears.
The list appears in a pop-up window.
(3) Select a device. The selected device name and directory (memory:
(Ex.) Menu Memory /program) appear in the device name and directory
display columns.
(Note) When the number of characters of directory path (full path) exceeds 48, changing directories
cannot be performed.
I - 309
4. Edit Screen
4.3 Program Check (2D)
(6) Press the Check continu key. A program check is executed and that path is drawn.
A "Checking" message appears and the menu is
A block stoppage occurs when performing highlighted.
a program check if the Check continu The check counter display is updated.
or Check step keys are pressed while The check G modal does not display.
performing a continuous check. The machining time is updated.
Furthermore, the program check is
restarted if the Check continu key is
pressed during the block stoppage.
I - 310
4. Edit Screen
4.3 Program Check (2D)
Operation method
(1) Press the main menu Check . The program check screen becomes active.
(3) Press the menu Check step . The program check is executed for one block, and a
graphic drawing of the machining program movement
path is made.
The check counter display is updated.
The check G modal display is updated.
I - 311
4. Edit Screen
4.3 Program Check (2D)
(4) Press the menu Check step . The program check is executed for the next block.
The menu returns to normal state.
The program check is continued from the
next block if the Check continu key is
pressed during block stoppage.
Operation method
(1) Press the menu Check reset . The program check is reset and a "Reset complete"
message appears.
I - 312
4. Edit Screen
4.3 Program Check (2D)
(1) Press the menu Display range . A white frame indicating the display range appears on
the screen.
The display range input mode is activated, and the
following menu appears.
(2) Press the menu Zoom In or Zoom out. The size of the white frame can be changed by using
key operations.
To enlarge the drawing size:
Press the menu Zoom In or - key.
To reduce the drawing size:
Press the menu Zoom out or +
key.
I - 313
4. Edit Screen
4.3 Program Check (2D)
(1) Press the menu Display range . A white frame indicating the display range appears on
the screen.
The display range input mode is activated, and the
following menu appears.
(2) Press the Up , Down , Left , Right The cursor () indicating the center of the display and
the frame line move up, down, left and right according
menu or cursor movement keys ↑ , ↓, to the key operations.
←, → .
(3) Press the INPUT key. The display position changes so that the cursor
position () is the center of the area.
By changing the display position, the graphic data
displayed on the screen is erased, however, the scale
value is not changed.
(Note 1) When changing the display range while the 2-plane display mode such as "XY/XZ", the display
range (scale and display position) for the upper and lower areas changes in the same manner.
The operation method is the same as the 1-plane display mode.
The white-framed display range in the upper and lower areas simultaneously move to the left/right
when the Left , Right keys are pressed.
The white-framed display range of either upper or lower areas moves up and down when the
Up , Down keys are pressed.
Which frame to be moved up/down can be changed with the page key.
(Note 2) The set displayed position will be held even after the power is turned OFF and ON again.
I - 314
4. Edit Screen
4.3 Program Check (2D)
(1) Press the menu Display range . A white frame indicating the display range appears on
the screen.
The display range input mode is activated, and the
following menu appears.
(2) Press the Centering . The display position is changed so that the current
machine position appears in the center of the drawing
area.
(Note 1) In the 2-plane display mode such as "XY/XZ", centering is applied for the upper and lower areas.
The operation method is the same as the 1-plane display mode.
(Note 2) When the Centering menu key is pressed after the display scale has changed, only the
centering is applied without changing the scale value.
I - 315
4. Edit Screen
4.3 Program Check (2D)
(Note 1) When the display mode is changed, the graphics displayed up to that point are erased.
(Note 2) These set display mode is maintained even after rebooting the machine.
(Note 3) The display mode can be set independently at the trace function and program check function. These
settings are not linked with one another.
(Note 4) The menu axis names XYZ are compatible with the basic axes IJK. X = base axis I, Y = base axis J,
and Z = base axis K.
(1) Set the axis name and press the INPUT XYZ appears the graphic display mode name.
key. There are 3 drawing axes: X, Y, and C.
XYC INPUT
There are three types of display mode: 1- plane, 2- plane, and 3D. An image displays which display mode
is currently selected. The selected axis name displays for the image axis name.
Display example
<1-plane> (XY) <2-plane> (XY/XZ) <3-dimension> (XYZ)
I - 316
4. Edit Screen
4.3 Program Check (2D)
(Note 1) When the display angle is changed, the graphics displayed up to that point are erased.
(Note 2) The set display angle is maintained even after rebooting the machine.
(Note 3) The display angle can be set independently at the trace function and program check function. These
settings are not linked with one another.
Operation method
(1) Press the menu Rotate . The mode changes to the rotation mode and the
following menu appears.
Up Down Left Right
(2) Use the Up , Down , Left , Right Rotate the cubic display in the lower right of the screen
menu to adjust the display angle. using the operation keys.
Z Z
The cursor movement keys ( ↑ , ↓ , X Y
← , → ) can also be used to rotate. Y X
(Note 1) The set display angle is maintained even after rebooting the machine.
I - 317
4. Edit Screen
4.3 Program Check (2D)
Press the All display menu key to display the program check window on the whole screen. (full-screen
display mode).
Press this menu again to return the normal display.
All display
menu : ON
All display
menu : OFF
(Note 1) The selected display mode is maintained even after rebooting the machine.
(Note 2) The full-screen display mode is applied to the trace function and program check (2D/3D solid)
function commonly.
(Note 3) The full-screen display mode is applied commonly to all part systems.
Displaying a program
When pressing the Program display menu key, the contents of the machining program on checking is
displayed on the drawing area.
When pressing the Program display again, the displayed program is erased.
Note that this menu can be used only when the full-screen display mode is selected.
(Note 1) The selected display mode is maintained even after rebooting the machine.
(Note 2) The program display mode is applied to the trace function and program check (2D) function
commonly.
(Note 3) The Program display menu key cannot be selected while the normal display mode is selected.
Program display mode is valid only when the full-screen display mode is selected.
(Note 4) The program display mode is applied commonly to all part systems.
I - 318
4. Edit Screen
4.3 Program Check (2D)
I - 319
4. Edit Screen
4.3 Program Check (2D)
#1
4.3.10 Handling of Variable Commands, Parameter Input by Program, and Compensation Data
Input by Program
If a program check is performed for a machining program for which the variable command data etc. is
rewritten, all data types are treated as shown in the following table after completion.
I - 320
4. Edit Screen
4.3 Program Check (2D)
Check function
(1) The check function draws while referring only to the NC internal operation results. Thus, the path is not
drawn for commands requiring machine movement.
(2) Check search and check start are not possible during automatic start or automatic pause. The operation
message "Executing automatic operation" appears.
(3) Operation search is possible for a program with 32 or less file name characters.
(4) Graphic check is not available for MDI program.
Notes for checking (Common for continuous check and check step)
(1) When the menu Zoom in , Zoom out , Display mode , Rotate or Display range key is pressed
while checking, the graphic data is erased, however, the program check is not interrupted.
(2) Drawing is continued even after changing to another screen while checking.
(3) Automatic operation cannot be performed even if the automatic operation button is pressed while
checking. “M01 Operation Alarm (0112)" occurs.
(4) Execute automatic start after the check is completed or after the check is interrupted by pressing the
Check reset .
(5) Refer to "4.3.10 Handling of Variable Commands, Parameter Input by Program, and Compensation Data
Input by Program " for further details on all types of data set in the program while checking.
(6) Checking the program stops if there is a M00/M01 command. However, when executing the M01
command, drawing is stopped regardless of the ON/OFF status of the optional stop switch signal.
(7) When switching part systems during checking, drawing will be erased. When the displayed part system is
undone, check operation will be continued from the previous state (program position before part systems
were switched).
(8) Status during checking (in "Check continu"/in "Check step") is held per part system.
(9) 2D graphic check drawing begins from the actual coordinate value used for the program operation
(coordinate value of the machine position).
(10) The contents of ONB display and buffer display in the check screen during automatic operation are the
contents of the program during automatic operation. The contents of ONB display and buffer display in
the operation screen during check execution are the contents of the program during check execution.
(11) When operation search or check operation ("Check continu" or "Check step") is performed during
program restarting, the operation message "in program restarting" is displayed, and the program will not
be searched or graphically checked.
I - 321
4. Edit Screen
4.3 Program Check (2D)
(1) The checking mode is released when the trace mode becomes ON.
(2) Graphic check (2D) cannot be performed during the trace mode.
(3) When displaying Edit screen during the graphic trace mode, graphic check 3D will be applied regardless
of the previous check type. If the 3D solid check option is not valid, the area of Check tag will be blank.
(4) When trace window is displayed during check, check will be terminated. (This applies for all the part
systems under checking.)
I - 322
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Program check (3D) is a function that draws the workpiece shape and tool movement in the cutting process
of the machining program as a solid image without executing automatic operation. The machining program
can be checked with graphic data drawn at a high speed.
This function requires workpiece and tool shape settings.
Program check (3D) can draw a solid image in the basic machine coordinate system or the workpiece
coordinate system.
The coordinate system used to draw can be switched on "Work set" screen.
In the workpiece coordinate system, a solid image is drawn by using the workpiece coordinate system
designated by the program.
Using All display menu, normal display and full-screen display modes can be switched.
(Note 1) The program check (3D) function is an additional specification. The graphic check and 3D solid
graphic check option is required.
(Note 2) When changing the screen to the edit screen, display depends on the previous checking type
(2D/3D). Note that when selecting this screen during graphic trace, 3D solid program check will
apply.
If the 3D solid check option is not valid in this time, the area of Check tag will not be blank.
(1) (5)
(2) (6)
(3)
I - 323
4. Edit Screen
4.4 Program Check (3D) [700 series only]
(1)
(2) (3)
(5)
(4)
Display items
I - 324
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Menus
(Note 1) When the graphic trace mode is entered and automatic operation is running, the menu
Operate search , Check continu , Check step , Check reset cannot be selected and
the 3D solid program check cannot be performed.
Only the 3D solid program check can be performed unless the automatic operation is running.
(Note 2) The menu 2D check , Operate search , Work setting , Tool setting cannot be selected
while the check is performed or interrupted.
I - 325
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Operation method
(1) Press the main menu Check . The program check screen becomes active.
(2) Press the Operate search key. The following menu appears.
The list appears in a pop-up window.
(3) Select a device. The selected device name and directory (memory:
(Ex.) Menu Memory /program) appear in the device name and directory
display columns.
(Note) When the number of characters of directory path (full path) exceeds 48, changing directories
cannot be performed.
I - 326
4. Edit Screen
4.4 Program Check (3D) [700 series only]
(6) Press the Check continu key. A program check is performed, and a solid drawing is
made for the cutting process workpiece shape and tool
A block stoppage occurs when performing movement.
a program check if the Check continu A "Checking" message appears and the
or Check step keys are pressed while Check continu menu is highlighted.
performing a continuous check. The check counter display is updated.
Furthermore, the program check is The check G modal does not appear.
restarted if the Check continu key is The machining time is updated.
pressed during the block stoppage.
A "Program check completed" message appears when
The program check is reset if the the continuous check is completed.
Check reset key is pressed while The Check continu menu highlight returns to
performing a continuous check. normal.
Operation method
(1) Press the main menu Check . The program check screen becomes active.
(3) Press the menu Check step . The program check is executed for one block, and a
solid drawing of the workpiece shape and tool
movement during the cutting process is made.
The check counter display is updated.
The check G modal display is updated.
The machining time is updated.
(4) Press the menu Check step . The program check is executed for the next block.
Operation method
(1) Press the menu Check reset . The program check is reset and a "Reset complete"
message appears.
I - 327
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Operation method
(1) Press the menu Zoom . The mode changes to the enlargement/reduction
mode, and the following menu appears.
Zoom Zoom
in out
(2) Press the menu Zoom in . The drawing area center position is set in the center,
and the enlarged workpiece is redisplayed.
To enlarge the drawing:
Press the menu Zoom in or - key.
To reduce the drawing size:
Press the menu Zoom out or + key.
Operation method
(1) Press the menu Move . The mode changes to the movement mode and the
following menu appears.
Up Down Left Right
(2) Use the Up , Down , Left , Right The workpiece shape moved in the designated
keys to adjust the display position. direction is redisplayed.
Operation method
(1) Press the menu Rotate . The mode changes to rotation mode and the following
menu appears.
Up Down Left Right
(2) Use the Up , Down , Left , Right The workpiece shape rotated in the designated
keys to adjust the display angle. direction is redisplayed.
(Note 1) The set display angle is maintained even after rebooting the machine.
I - 328
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Operation method
(2) Press the menu Check step or A program check is performed, and a solid drawing of
the workpiece shape and tool movement during the
Check continu .
cutting process is performed.
A "Checking" message is displayed and the menu
Check step or Check continu key is highlighted.
The workpiece and tool contact, this is drawn in a color
highlighting the interference.
Press the All display menu key to enlarge the program check window (full-screen display mode).
Press this menu again to return the normal display.
All display
menu : ON
All display
menu : OFF
(Note 1) The selected display mode is maintained even after rebooting the machine.
(Note 2) The full-screen display mode is applied to the trace function and program check (2D/3D solid)
function commonly.
(Note 3) The full-screen display mode is applied commonly to all part systems.
I - 329
4. Edit Screen
4.4 Program Check (3D) [700 series only]
(2)
(1)
Display items
I - 330
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Menus (the cursor is at WorkRefPoint(I,J,K) (material basic point), or WorkWidth (material width))
Pink
I - 331
4. Edit Screen
4.4 Program Check (3D) [700 series only]
(2) Press the menu Work coord. "Work coord" appears at the cursor position.
The cursor moves one place down.
It is also possible to set input values. A guide drawing with workpiece coordinate origin
0 INPUT : Machine coord appears in the guide drawing area.
1 INPUT : Work coord
When the drawing coordinate system is the workpiece coordinate, the drawn coordinate system can be
selected. Only the coordinate system selected here is drawn.
When the drawing coordinate system is the machine coordinate, "All Wk. Coord" (all workpiece
coordinates) is set at "Coord Select" (workpiece coordinate system selection). Therefore,
Coord G54-G59 or Coord G54.1P menu cannot be selected.
(2) Press the menu Coord G54-G59. The sub-menus, which select G54 to G59, are
displayed.
(3) Press the menu G56. "G56" appears at the cursor position.
The cursor moves one place down.
The sub-menus of the material shape (WorkForm) are
When Return menu is selected, return to
displayed.
Coord Select menu.
(2) Press the menu Block . "Block" appears at the cursor position.
The cursor moves one place down.
It is also possible to set input values. A block guide drawing appears in the guide drawing
0 INPUT : Default shape area.
1 INPUT : Block
I - 332
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Setting the material basic point (WokRefPoint (I)) and size (WrkWidth (I,J,K))
Enter the material basic point and size. Specify the material basic point with the specified coordinate on
"Work set" screen.
(1) Use the ↑ , ↓ keys to move the cursor
to the material basic point or width (I)
setting column.
(Note 1) The workpiece will not be displayed if two or more size data are "0".
(Note 2) The setting range of the material basic point and width is as follows.
However, the value of less than 0 cannot be set to width.
(2) Press the material color menu. The cell where the cursor is located appears in gray.
(Ex.) Menu Gray The cursor moves one place down. (The cursor does
not move when at the cross section color.)
It is also possible to set input values.
0 INPUT : Default color
1 INPUT : Gray
2 INPUT : Red
3 INPUT : Yellow
4 INPUT : Blue
5 INPUT : Green
6 INPUT : Light blue
7 INPUT : Purple
8 INPUT : Pink
I - 333
4. Edit Screen
4.4 Program Check (3D) [700 series only]
By combination of the drawing coordinate system (CoordinateSystem) and the workpiece coordinate
system selection (Coord Select), the drawing at 3D check changes as follows.
(Example)
[Parameter] [Machining program]
#8920 = 1 N1 G28 XYZ
[Tool compensation] N2 T1 M6
No.1 : Length 150.000 L wear 0.000 N3 G43 H1
Radius 20.000 R wear 0.000
[Workpiece coordinate] N10 G0 G90 G59 X100. Y100. Z0.
G59 : X 50.000 Y 50.000 Z 0.000 N11 G91 G01 Z-200. F100
G54.1P1 : X 200.000 Y 200.000 Z 0.000 N12 G02 I-15
[Workpiece shape setting] N13 G01 Z200.
Workrefpoint (I,J,K) = (0.000, 0.000, -200.000)
WorkWidth (I,J,K) = (500.000, 500.000, 100.000) N20 G0 G90 G54.1 P1 X200. Y200. Z0.
N21 G91 G01 Z-200. F100
N22 G02 I-15
N23 G01 Z200.
M30
%
Coord
CoordinateSystem Drawing result when 3D check in example
Select
Machine Coord All wk. Arranges the workpiece based
coord on the machine coordinate zero
point.
N12 Draws the tool movement of all
workpiece coordinate systems
N22 on the basic machine coordinate
system.
Workpiece coordinate
zero point G59
I - 334
4. Edit Screen
4.4 Program Check (3D) [700 series only]
(2)
(1)
(3)
Display items
I - 335
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Drill
Bulnose
endmill
Chamfer
Tap
Menus (when the cursor is at Radius (tool radius), Length (tool length), or ToolData1,2 (shape data)
Gray
Red
Yellow
Blue
Green
Light
blue
Purple
Pink
I - 336
4. Edit Screen
4.4 Program Check (3D) [700 series only]
(2) Input the Tool No. "10" appears at the cursor position.
(Ex.) 10 INPUT The cursor moves one place to the right.
(Note 1) Register a new tool data to set the default value for the tool type, tool radius, tool length, and
shape data 1,2, and tool color.
(Note 2) If two or more of the same tool number is registered, the tool shape data that is registered first is
selected.
(Note 3) When an unregistered tool is selected, the previously used tool is used as is.
Clearing the tool data (Clearing tool data for one line at the cursor position)
(2) Input as shown below. The contents of the line where the cursor is located are
0 INPUT all cleared.
The cursor does not move.
(3) Press the INPUT key. Background color of the line at the cursor position is
turned to light blue.
The operation message
"Erase?(Y/N)" is displayed.
(4) Press the Y or INPUT key. The contents of the line where the cursor is located are
all cleared.
Press any key other than Y and Background color of the line at the cursor position is
INPUT to cancel. returned.
The cursor does not move.
The menu highlight is returned to normal.
I - 337
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Clearing the tool data (Clearing tool data for multiple lines)
(2) Set the first and last tool No. of the area to The background color of the lines for tool No. 20 to 50
be cleared by dividing by "/" and press the is highlighted in light blue.
INPUT key. The operation message "Erase? (Y/N)" appears.
When the tool data to be cleared does not exist within
20/50 INPUT
the page currently being displayed, the cursor is
moved to the first line of the area to be cleared,
making it the top of the display area.
Specify the last line "E" to make it the end of the
clearance range.
(Example) 10/E
(3) Press the Y or INPUT key. The contents of the line highlighted in light blue are all
cleared.
Press any key other than Y and Background color is returned.
INPUT to cancel. The menu highlight is returned to normal.
(Note 1) A setting error occurs when the specified tool No. does not exist.
(Note 2) A setting error occurs when the specified ending tool No. does not exist in the lower line than the
starting tool No.
(Note 3) When the area to be cleared ranges over 2 pages, tools in the specified area in the second page
and after will be cleared, as well.
(Note 4) When two or more of the same tool Nos. are specified, tool data of the tool number registered
first is cleared.
(2) Press the tool type menu. "Ball endmill" appears at the cursor position.
(Ex.) Menu Ball endmill The cursor moves one place to the right.
The ball end mill guide drawing (note) appears in the
It is also possible to set input values. guide drawing area.
0 INPUT : Default tool
1 INPUT : Ball end mill
2 INPUT : Flat end mill
3 INPUT : Drill
4 INPUT : Bull nose end mill
5 INPUT : Chamfer
6 INPUT : Tap
(Note) The drill appears in the guide drawing area when the default tool is designated.
I - 338
4. Edit Screen
4.4 Program Check (3D) [700 series only]
(2) Press the tool color menu. The cell where the cursor is located appears in green.
(Ex.) Menu Green The cursor moves to the tool number column one line
below.
It is also possible to set input values.
0 INPUT : Default color
1 INPUT : Gray
2 INPUT : Red
3 INPUT : Yellow
4 INPUT : Blue
5 INPUT : Green
6 INPUT : Light blue
7 INPUT : Purple
8 INPUT : Pink
(Note) The tool appears in red when the default color is designated.
I - 339
4. Edit Screen
4.4 Program Check (3D) [700 series only]
4.4.12 Handling of Variable Commands, Parameter Input by Program, and Compensation Data
Input by Program
Refer to "4.3.10 Handling of Variable Commands, Parameter Input by Program, and Compensation Data Input
by Program".
Check function
(1) The check function draws while referring only to the NC internal operation results. Thus, the path is not
drawn for commands requiring machine movement.
(2) Check search and check start are not possible during automatic start or automatic pause. The operation
message "Executing automatic operation" appears.
(3) Operation search is possible for a program with 32 or less file name characters.
(4) Graphic check is not available for MDI program.
Notes for checking (Common for continuous check and check step)
(1) The drawing is not initialized and the program check is not interrupted even if the menu Zoom ,
Move , or Rotate key is pressed while checking.
(2) Check reset is applied when changing to another screen while checking.
(3) Automatic operation cannot be performed even if the automatic operation button is pressed while
checking. An operation alarm ("Program check mode") occurs.
Execute automatic start after completing the check or after stopping the check by pressing the
Check reset
(4) Refer to "4.3.10 Handling of Variable Commands, Parameter Input by Program, and Compensation Data
Input by Program" for further details on all types of data set in the program while checking.
(5) The program stops if there is a M00/M01 command. However, when executing the M01 command,
drawing is stopped regardless of the ON/OFF status of the optional stop switch signal.
(6) The tool shape is drawn using the value set in "Tool set" window (Radius, Length, ToolData1,2).
As for the tool moving path, select with the parameter "#8920 3D tool Ofs Select", whether the tool
compensation amount (radius dimension/length dimension) in Tool compensation screen is added to the
path or not.
When the compensation amount is added, pay an attention so that the compensation No. during tool
length/radius compensation and T command value is the same number. Failure to observe this could
result in over cutting or insufficient cutting because the tool shape does not match the machine position.
(7) If the following data for new tool is "0" or no setting when changing the tool, the new tool is drawn with the
default setting.
•Type : "Drill" is selected when "Kind" is not set.
•Length : 150mm (5.90 inch) when "Length" is "0".
•Radius : 20mm (0.79 inch) when "Radius" is "0".
•Color : "Red" is selected when "CL” is not set.
(8) When the parameter "8920 3D tool Ofs Select" is set to "0" or "1", tool is drawn with its radius the default
value (20mm) if the tool radius to be displayed is "0" or less.
I - 340
4. Edit Screen
4.4 Program Check (3D) [700 series only]
(9) The menu related to graphic function cannot be selected during the automatic operation with the trace
mode ON.
(10) The zero point mark is not drawn.
(11) The contents of ONB display and buffer display in the check screen during automatic operation are the
contents of the program during automatic operation. The contents of ONB display and buffer display in
the operation screen during check execution are the contents of the program during check execution.
(12) When operation search or check operation ("Check continu" or "Check step") is performed during
program restarting, the operation message "in program restarting" is displayed, and the program will not
be searched or graphically checked.
(1) Set the standby tool count in the parameters "#1327 3D ATC type". The tool replacement method with
each parameter is as follows. (Tool replacement commands other than M6 (M22, etc.) are not
supported.)
T2;
Machining M6T2; M6T3; M6T1;
process section Drawing by tool T1 Drawing by tool T1 Drawing by tool T1
I - 341
4. Edit Screen
4.4 Program Check (3D) [700 series only]
Drawing position
(1) Set the drawing position with the parameter "#8920 3D tool Ofs Select".
With the parameter "#8920 3D tool Ofs Select", select which data is used for calculation of the drawing
position (tool center point), the tool compensation amount stored in the NC memory or the data set in the
“Work set” window. In the table below;
"NC memory data" indicates "the compensation amount stored in the NC memory".
"3Ddata" indicates "the data set in the "Tool set" window".
Setting of
Tool shape data used for display Tool center position (Z axis)
#8920
Radius In G43 modal:
0 NC memory data
compensation Machine position - 3Ddata
(Tool measurement
Length In G44 modal:
type I) 3D data
compensation Machine position - 3Ddata
1 Radius In G43 modal:
(Tool measurement compensation Machine position - NC memory data
type II) Length NC memory data In G44 modal:
compensation Machine position + NC memory data
(Note) This setting cannot be used with tool
measurement type I.
2 Radius In G43 modal:
(Tool measurement compensation Machine position - 3Ddata
type I) 3D data
Length In G44 modal:
compensation Machine position - 3Ddata
3 Radius In G43 modal:
(Tool measurement compensation Machine position - 3Ddata
type II) Length In G44 modal:
3D data
compensation Machine position - 3Ddata
(Note) This setting cannot be used with tool
measurement type I.
(Note 1) As for the 1st and 2nd axis (basic axis I,J) and the 3rd axis (basic axis K) during G49 (tool
compensation cancel mode), the machine position is applied to the drawing position.
(Note 2) In the workpiece coordinate system drawing, "Machine position" in above table means
"Workpiece coordinate position".
I - 342
4. Edit Screen
4.5 Program Input/Output
The machining program can input/output between the NC internal memory and the external input/output
device. The hard disk inside the NC unit is also treated as an external device.
This function applies to the following devices.
(1) Memory (NC internal memory)
(2) HD
(3) Serial
(4) Memory card (front IC card)
(5) DS (compact flash at NC)
(6) Ethernet
(7) FD
(8) Anshin-net server
(Note) In 70 series, only the memory, the serial, the memory card, Ethernet and Anshin-net server can be
used.
(4)
(3)
(2)
(5)
(6)
(7)
I - 343
4. Edit Screen
4.5 Program Input/Output
Display items
• When the Ethernet parameter "#97*1 Host n no total siz" is set to 1, the number of host memory
characters will not appear.
I - 344
4. Edit Screen
4.5 Program Input/Output
Menus
This changes the name of the file in file setting column A to that of in A 4.5.6 Changing a File
Rename
A→B file setting column B. Name (Rename)
(Note) The same device must be selected for A and B.
This creates a new directory in the selected file setting column. A 4.5.7 Creating a
Dir
create The directory can be created when HD, memory card, DS or FD is Directory
selected for the device.
Merge This adds the file contents of file setting column B to file setting A 4.5.8 Merging a File
B→A column A. (The file setting column B file is not affected.)
This closes the pop-up window and quits this function. C
Close
MemCrd The formats the memory card (front IC card). A 4.5.9 Formatting an
format External Device
DS This formats the DS. A
format This menu is only for 700 series.
FD This formats the FD. A
format This menu is only for 700 series.
This cancels a warning from network service. C 4.5.14 Sharing
Warning Machining Data
cancel "Canceling a warning
from network service"
This interrupts the process (transfer, compare, etc.) during its C
Stop
execution.
I - 345
4. Edit Screen
4.5 Program Input/Output
Changing file setting column B to a valid area (refer to upper right diagram)
(1) Press the → or →| key. File setting column B changes to a valid area.
Changing file setting column A to a valid area (refer to upper left diagram)
(1) Press the ← or |← key. File setting column A changes to a valid area.
I - 346
4. Edit Screen
4.5 Program Input/Output
Select a device where the file Select using the shortcut keys or sub-menu.
subject to the operation exists.
(1) The device can be selected using the sub-menu or shortcut keys.
(The devices that can be used will differ depending on the specifications.)
(2) One of the following methods can be used to designate the directory (for devices other than the NC
memory) and file name.
• Designate the directory path or file name in the input area and press the INPUT key.
• Move the cursor in the list display section to the target directory or file name and press the
INPUT key.
A wildcard (*) can be used for the file name.
(Note) When the number of characters of directory path (full path) exceeds 128, changing directories
cannot be performed.
(1) During directory and file name setting, the designated directory, path or file name will be set, even if it
does not actually exist. This will not cause an error. Note that the previously set directory is overwritten.
(2) When selecting a fixed cycle program, it is necessary to set the basic common parameter "#1166 fixpro".
Furthermore, select "Memory" for the device, and "Program" for the directory.
I - 347
4. Edit Screen
4.5 Program Input/Output
(1) Press the M short cut key. The device name changes to "Memory".
"Program" appears in the directory.
(2) Press the menu File set . The NC memory program list and input area appear.
I - 348
4. Edit Screen
4.5 Program Input/Output
[Ex. 2] When programs 1.PRG to 1000.PRG, and 1 to 1000 exist in the HD.
Designate "*" in the file name : The target program is "1 to 1000".
Designate "*.*" in the file name : The target program is "1.PRG to 1000.PRG".
Designate "1*" in the file name : The target program is "1, 10 to 19, 100 to 199, 1000".
Designate "1*.*" in the file name : The target program is "1.PRG, 10.PRG to 19.PRG, 100.PRG to
199.PRG, 1000.PRG".
Operation method (Selecting a file from a device other than the NC memory)
(1) Press a device selection shortcut key. The device name changes to "HD".
(Example) G The root directory (/) appears in the directory.
(2) Press the menu File set . The HD program list and input area appear.
I - 349
4. Edit Screen
4.5 Program Input/Output
I - 350
4. Edit Screen
4.5 Program Input/Output
Operation method
(2) Designate the transfer source device, The designated file displays in file setting column A.
directory and file name. A wildcard "*" can be used for the file name to
designate multiple files.
(4) Designate the transfer destination device, The designated file appears in file setting column B.
directory and file name.
(5) Press the menu Transfr A→B . A message appears to confirm the transfer.
(6) Press the Y or INPUT key. File transfer is commenced. The process progress
display area displays message indicating that transfer
is in progress, and also indicates the transfer direction.
Furthermore, the data being transferred appears in the
input/comparison data display area of the input data
display column.
! CAUTION
! " ; ", "EOB", "%", and "EOR" are symbols used for explanation. The actual codes for ISO are "CR,
LF" ("LF") and "%".
The programs created on the Edit screen are stored in the NC memory in a "CR, LF" format,
however, the programs created with external devices such as the FD or RS-232C may be stored
in an "LF" format.
The actual codes for EIA are "EOB (End of Block)" and "EOR (End of Record)".
! To prevent the influence of data loss and data transformation over the line, always carry out data
comparison after transferring a machining program.
I - 351
4. Edit Screen
4.5 Program Input/Output
(1) Depending on the type of file, some data cannot be transferred during automatic operation. Do not
transfer during automatic operation.
(2) When the capacity of the transfer destination is reached during file transfer, only the data transferred up
to that point is registered as a file, and an error will occur.
(3) During input to the NC memory or comparison, if the file format size on the NC memory side differs from
the other side file format size (when the maximum number of registrations differs between the NC
memory and the other side), processing is carried out matching the smaller size.
(Ex. 1) If a format size of 200 files is input for a format size of 1000 NC files, 200 files are registered.
(Ex. 2) If a format size of1000 files is input for a format size of 200 NC files, the files up to the 200th file
are registered and an error message appears. (The remaining files are not registered.)
(4) Up to 223 files, including the directory, can be registered in the FD's root directory.
(1) For the serial, always set both ends of the "EOR" code at the head and end to feed (NULL). If "EOB" etc.,
is directly after "EOR", the operation may not be executed normally due to the input buffer influence
during the next input operation.
(2) The transfer speed is slower if there are many registrations.
(3) The size of one block of the machining program to be transferred should be 250 characters or less.
(4) When using tape, carry out parity V adjustment to improve the reliability of the tape format. Then use it
with the input/output parameter "Parity V" validated.
(5) When the machine tool builder macro and fixed cycle program are input, change the program type with
the parameter (#1166 fixpro). Also, set the device and directory as follows.
Device: Memory, Directory: Program
(6) Transferring or verifying the multiple files between the external device connected serially and that other
than the serial connection.
(7) With machining program created by the MELDAS500 Series or earlier model, "EOB" is registered as "LF".
However, when these programs are stored in the 700/70 Series NC memory, "EOB" will be converted to
"CR LF", and the number of characters will increase. Thus, when all of the machining programs output
from an MELDAS500 Series or earlier model, having the same specifications as the maximum memory
capacity, are stored in the 700/70 Series NC memory, the memory capacity may be exceeded.
(8) When the file to be transferred (input) is running or in "program restarting" mode, the operation message
"Executing automatic operation" or "Program restarting" is displayed and file will not be transferred
(input).
I - 352
4. Edit Screen
4.5 Program Input/Output
Operation method
(2) Designate the device, directory and file The designated file name appears in file setting
name to be compared. column A.
(4) Designate the other device, directory and The designated file name appears in file setting
file name to be compared. column B.
(5) Press the menu Compare A:B . The file comparison starts.
The input data and comparison data appear in the
input/comparison data display area.
A message appears when the comparison is
completed.
If a comparison error occurs, the block with the error is
displayed in the comparison data display column on
the screen.
I - 353
4. Edit Screen
4.5 Program Input/Output
(2) Designate the device, directory and file The designated file appears in file setting column A.
name to be erased.
(3) Press the menu Erase . A message to confirm the erasing appears.
Use the → or →| key to select file setting column B, and designate the device, directory, and file name for file
setting column B. Following this, the operation method is same as for "Deleting a file in file setting column A".
I - 354
4. Edit Screen
4.5 Program Input/Output
(2) Designate the device, directory and file The designated file appears in file setting column A.
name before the change.
(4) Designate the device, directory, and file The designated file appears in file setting column B.
name after the change.
(Note 1) Make sure the original and new devices are the same.
(Note 2) If the file to be renamed is running or program restarting, an error will occur, and the name will
not be changed.
(Note 3) If a file that does not exist is designated for the original file, or if an existing file name is
designated for the new file selection, an error occurs, and the name is not changed.
(Note 4) The directory where the file in operation search/check search is stored cannot be renamed. The
operation message "Can't rename designated file" appears.
I - 355
4. Edit Screen
4.5 Program Input/Output
Operation method
(3) Select a directory to be newly created from The designated details appear.
the list, or designate by inputting from the
input area.
(4) Set the new directory in the input area and The set directory name appears.
press INPUT key.
(Note1) Up to 223 files, including the directory, can be registered in the FD's root directory.
(Note2) Make sure that the directory path is less than 100 characters. When the path exceeds 100
characters, it cannot be recognized as a path.
I - 356
4. Edit Screen
4.5 Program Input/Output
Operation method
(2) Designate the merge destination device, The designated file name appears in file setting
directory, and file name. column A.
(4) Designate the merge source device, The designated file name appears in file setting
directory, and file name. column B.
(5) Press the menu Merg B→A . A message confirming the merge appears.
(Note 1) If the merge destination file (file in file setting column A) is running, an error will occur, and the
files will not be merged.
(Note 2) The devices that can be merged are the memory, HD, FD, memory card and DS.
I - 357
4. Edit Screen
4.5 Program Input/Output
(1) Insert a floppy disk in the FD drive, and A message confirming the formatting appears.
press the menu FD format
(1) Press the menu MemCrd format . A message confirming the formatting appears.
First, press the menu DS format . The following operations are the same as "Formatting a memory card".
I - 358
4. Edit Screen
4.5 Program Input/Output
Machining program A
1 to 7999
Machining program B
(user standard program)
8000 to 8999
Machining program C Editing Editing prohibited
(machine tool builder custom prohibited by by Edit lock B
program) Edit lock C
9000 to 9999
Machining program A
10000 to 99999999
The operations below in the Edit MDI and the Input/Output screens are influenced by the edit lock setting.
An error will occur if operations that are not possible are attempted.
When the edit lock is valid, processing is executed (except the edit lock target program) by the input/output
function.
(Note) When the multiple part system specification is valid, the machining programs of all the part systems
are protected by edit lock B and C.
I - 359
4. Edit Screen
4.5 Program Input/Output
#1122 pglk_c
Screen operation 1 (Display:{ Search:×) 2 (Display:× Search:×)
Buffer display of operating The program contents are not displayed. Only "%" is displayed.
program
Display when Program display
highlights on 2D check
full-screen
When the menu Edit was The operation message "Program display lock C" appears.
pressed The window is opened.
When the main menu P corr (When the edit lock B or C is valid, edit lock B or C is given to
was pressed priority.)
Search from the operation The search can be executed. The search cannot be
search window executed.
Search from the restart search The operation message
window "Program display lock C"
Search from the top search appears. The window is not
window (of restart search) closed. The contents of input
area are not cleared.
#1122 pglk_c
1 (Display: Search: ) 2(Display: Search: )
Screen operation
The file is automatically opened The program contents are not -
when changing the edit screen displayed. Only "%" is (It is not possible to search, so
(Note 1) displayed. the file is never automatically
opened when changing the
edit screen.)
When the file is opened by the The operation message "Program display lock C" appears.
menu Open. The window is not closed.
(When the edit lock B or C is valid, edit lock B or C is given to
priority.)
When the main menu P corr The program contents are not displayed. Only "%" is displayed.
was pressed
Right side program display
when check main menu is
selected
Search from the operation The search can be executed. The search cannot be
search window of 2D/3D check executed.
The operation message
"Program display lock C"
appears. The window is not
closed.
(Note 1) When changing the edit screen, the file opened immediately before or operation searched/check
searched is automatically opened.
I - 360
4. Edit Screen
4.5 Program Input/Output
(1) KEY1: Provides general protection for tool data and protection of the coordinate system preset using
the origin set.
(2) KEY2: Protects user parameters and common variables.
(3) KEY3: Protects the machining program.
Data settings and deletion is stopped if any of the data protection keys is OFF.
(Note 1) If editing or settings, etc. are performed on the screens shown above when KEY3 is OFF, a "Data
protect" message appears.
(Note 2) When the multiple part system specification is valid, editing and input/output of the machining
programs of all the part systems are prohibited by KEY3.
I - 361
4. Edit Screen
4.5 Program Input/Output
Operation method
(2) Designate the transfer source device, The designated file appears.
directory and file name.
(4) Press the menu File set . The designated file appears in file setting column B.
(5) Press the menu Anshin net to “Anshin-net server” is displayed as device name.
designate the transfer destination device The file name, unless specified, is as same as the
and file name. name of the originally transferred file.
Only numbers within 10 characters can be used for
a file name.
(6) Press the menu Transfr A→B . A message appears to confirm the transmission of
machining data.
(Note 1) Neither HD operation nor memory card operation can be performed during file transmission from
HD.
(Note 2) Only one file can be saved on Anshin-net server. The file previously exists on the Anshin-net server
is overwritten.
(Note 3) Anshin-net icon appears in the upper middle of the screen during Anshin-net communications.
(Note 4) When Anshin-net server is specified as device name, the directory button is displayed in gray and
cannot be selected.
I - 362
4. Edit Screen
4.5 Program Input/Output
(3) Press the menu Anshin net to “Anshin-net server” as device name and the
designate the transfer source device and designated file name are displayed.
file name.
(5) Designate the transfer destination device, The designated file appears.
directory and file name.
(6) Press the menu Transfr A→B . A message appears to confirm the reception of
machining data.
When the file name is not designated in the file setting
column A, the message “File name not designated for
dev A” appears to indicate the error.
(7) Press the Y or INPUT key. The reception of machining data starts.
A message appears upon the completion of reception.
(Note 1) When the same file name exists in the transfer destination device, an error occurs and the transfer
cannot be executed.
(Note 2) Anshin-net icon appears in the upper middle of the screen during Anshin-net communications.
(Note 3) When Anshin-net server is specified as device name, the directory button is displayed in gray and
cannot be selected.
I - 363
4. Edit Screen
4.5 Program Input/Output
(3) Press the menu Anshin-net to “Anshin-net server”, as device name, and the
designate the file name to erase. designated file name are displayed.
(4) Press the menu Erase A . A message appears to confirm the erasing.
(1) Press the menu key Warning cancel . The warning message from network service is cleared.
(Note 1) A warning message from network service appears when any error occurs during communications.
(Note 2) NC reset can also clear the warning message from network service.
Notes
I - 364
5. Diagnosis Screens
5.1 System Configuration Screen
5. Diagnosis Screens
5.1 System Configuration Screen
The hardware configuration (card name and sub-number), software configuration (software number and
sub-number), and PLC program configuration (file name, file label, and execution type) are displayed in this
screen.
Software configuration
(1)
Hardware configuration
(2)
(3)
I - 365
5. Diagnosis Screens
5.1 System Configuration Screen
(4)
(4)-a
(4)-b
(4)-c
(4)-d
Display items
There are up to three channels. The 7th and 8th station of the
RIO3 channel is fixed for use with the handle I/F and is not
displayed.
I - 366
5. Diagnosis Screens
5.1 System Configuration Screen
There are up to three channels. The 7th and 8th station of the
RIO3 channel is fixed for use with the handle I/F and is not
displayed.
(4) PLC ladder file list This displays the file name, file label, execution type for each PLC ladder program.
Use ↑ , ↓ keys to change the pages and refer it.
(a) This displays the registration No. of each PLC program file.
Registration Registration size is max. 32 files.
No. The target file to be executed is max. 20 files.
(b) This displays the file name of PLC program file. (data of GX Developer)
File name Max. 8 characters.
(c) This displays this file label of PLC program file. (data of GX Developer)
File label Max. 32 characters.
(d) This displays the execution type of PLC program.
Execution
type Display Meaning
HIGH High-speed PLC program
MIDDLE Middle-speed PLC program
INTIAL Initial state of PLC program
WAIT Standby PLC program
LOW Low-speed PLC program
(blank) Not the target of the execution.
Menus
Ladder This displays the PLC program list (file name, file label, and execution C
config type
I - 367
5. Diagnosis Screens
5.2 Option Display Screen
(1)
Display items
I - 368
5. Diagnosis Screens
5.3 I/F Diagnosis Screen
(Note) Pay close attention to the sequence operation when using these functions during machine operation.
(3)
(2)
(1)
Display items
Display item Details
(1) Device No. and This displays the data from the device Nos. designated in the setting area in numerical
input/ output order.
signal value The data is displayed as binary (bit units) and hexadecimal values.
(binary/ Individual device Nos. can be displayed separately in the left area and right area.
hexadecimal Select the valid area with theand |← key when →| operations such as display
display) changeover and data setting are carried out.
Each X, Y, M, F, L, SM, TI, TO, TS, TA, STI, STO, STS, STA, CI, CO, CS, CA, D, R,
SB, B, V, SW, SD, W, P, K, and H data is the target data.
(2) Modal output This displays the data and device to carry out modal output.
The details to be defined are set here when carrying out the modal type forced output
of PLC interface signals.
Refer to "5.3.2 Carrying Out Modal Output" for details.
(3) 1-shot output This displays the data and device to carry out one-shot output.
The details to be defined are set here when carrying out the one-shot type forced
output of PLC interface signals.
Refer to "5.3.3 Carrying Out One-shot Output" for details.
I - 369
5. Diagnosis Screens
5.3 I/F Diagnosis Screen
Menus
A device is an address for classifying a signal handled in the PLC. A device No. is a series of numbers
attached to that device.
7 6 5 4 3 2 1 0
X0008 1 0 1 0 0 0 0 1
XF XE XD XC XB XA X9 X8
X0018 0 0 0 0 1 0 0 0
7 6 5 4 3 2 1 0
High-order
R0010 1 0 1 0 0 0 0 1
8 bits
Low-order
0 1 1 0 1 0 1 0
8 bits
I - 370
5. Diagnosis Screens
5.3 I/F Diagnosis Screen
No. of
Device Device No. Units Details
points
X (*) X0 to X1FFF 8192 1-bit Input signals to the PLC. Machine input, etc.
Y Y0 to Y1FFF 8192 1-bit Output signals to the PLC. Machine output, etc.
M M0 to M10239 10240 1-bit For temporary memory
F F0 to F1023 1024 1-bit For temporary memory. Alarm message interface.
L L0 to L511 512 1-bit Latch relay (Backup memory)
SM (*) SM0 to SM127 128 1-bit Special relay
TI TI0 to TI703 704 1-bit Timer contact
TO TO0 to TO703 704 1-bit Timer output
TS TS0 to TS703 704 16-bit Timer setting value
TA TA0 to TA703 704 16-bit Timer current value
STI STI0 to STI63 64 1-bit Integrated timer contact
STO STO0 to STO63 64 1-bit Integrated timer output
STS STS0 to STS63 64 16-bit Integrated timer setting value
STA STA0 to STA63 64 16-bit Integrated timer current value
CI CI0 to CI255 256 1-bit Counter contact
CO CO0 to CO255 256 1-bit Counter output
CS CS0 to CS255 256 16-bit Counter setting value
CA CA0 to CA255 256 16-bit Counter current value
D D0 to D2047 2048 16-bit Data register
R (*) R0 to R13311 13312 16-bit File register
SB SB0 to SB1FF 512 1-bit MELSEC NET/10 link special relay
B B0 to B1FFF 8192 1-bit MELSEC NET/10 link relay
V V0 to V255 256 1-bit MELSEC NET/10 edge relay
SW SW0 to SW1FF 512 16-bit MELSEC NET/10 link special register
SD SD0 to SD127 128 16-bit MELSEC NET/10 special register
W W0 to W1FFF 8192 16-bit MELSEC NET/10 link register
(Note) The use of devices marked with a * mark in the device column has been determined.
Do not use devices other than those corresponding to the input/output signals with the machine side
(input/output signals of the remote I/O unit), even if it is an undefined vacant device.
I - 371
5. Diagnosis Screens
5.3 I/F Diagnosis Screen
(2) Set the device No. (X0020), and press the The device "X0020" appears at the head of the valid
INPUT key. display area.
(Note) When setting the device No., an error will occur if a number exceeding the specifications or an illegal
address is set.
The valid area device Nos. change in page units when / is pressed. Changing of the pages stops
within the range of device numbers of which the device has.
(1) Press the key. The data is displayed from the next number
currently displayed.
I - 372
5. Diagnosis Screens
5.3 I/F Diagnosis Screen
(1) Press the menu key Modal output . The modal output mode is entered, and the cursor
appears at the modal output area.
(3) Set the device and data, and press the Modal output is executed, and the cursor disappears.
The data that was in the cursor position is overwritten
INPUT key.
by the input data, and is invalidated.
The modal output mode is cancelled by pressing the
X0048/1 INPUT
key.
(Note 1) The data of the modally output device is displayed in order in the selected area.
This modal output is held until the output is cancelled or the power is turned OFF.
(Note 2) When no data is set (Ex."X0048/","X0048"), the operation message "Setting Data not found" is
displayed.
(1) Press the menu key Modal output . The modal output mode is entered, and the cursor
appears at the modal output area.
(3) Press the menu key Modal clear . The data that was in the cursor position is released
from modal output. The "DEV" and "Data" columns
become blank.
The modal output mode is cancelled by pressing the
key.
! Caution
! Pay close attention to the sequence operation when carrying out forced data setting (forced output)
in the I/F diagnosis screen during machine operation.
I - 373
5. Diagnosis Screens
5.3 I/F Diagnosis Screen
(1) Press the menu key 1-shot output . The one-shot output mode is entered, and the cursor
appears at the one-shot output area.
(2) Set the device and data, press the The input data is overwritten in the one-shot output
INPUT key. area, and is one-shot output. The cursor in the
one-shot output area disappears.
The data of the one-shot output device is displayed in
X0042/1 INPUT
order in the selected area.
The one-shot output mode is cancelled by pressing the
key.
(Note 1) Because the input signal (X, etc.) to the PLC is updated at the head of each PLC cycle, the
machine immediately returns to the normal state, even if one-shot type forced output is carried
out.
(Note 2) When no data is set (Ex.: "X0048/","X0048"), the operation message "Setting Data not found" is
displayed.
! Caution
! Pay close attention to the sequence operation when carrying out forced data setting (forced output)
in the I/F diagnosis screen during mach
I - 374
5. Diagnosis Screens
5.4 Drive Monitor Screen
(1)
(2)
Display items
I - 375
5. Diagnosis Screens
5.4 Drive Monitor Screen
Menus
Spindle This displays the diagnosis information of the spindle unit in the data B 5.4.2 Spindle unit
unit display area. display items
Power This displays the diagnosis information of the power supply unit in the B 5.4.3 Display items for
unit data display area. the power supply unit
This monitors the various data related to the auxiliary axis (MR-J2-CT) B 5.4.4 Display items for
servo control. the auxiliary axis unit
AUX
unit The menu appears and operation is possible only when there is one or
more valid auxiliary axes in the auxiliary axis control.
This menu is only for 700 series.
This displays the diagnosis information of the synchronous error in the B 5.4.5 Display items for
Synchro data display area. the synchronous error
error The menu appears and operation is possible only when the
synchronous control axis option is valid.
Alarm This clears the diagnosis information alarm history. A 5.4.6 Clearing the alarm
his clr history
This displays the data for the next four axes. C
Next
axis The menu appears and operation is possible only when diagnosis
information for five or more axes is displayed.
I - 376
5. Diagnosis Screens
5.4 Drive Monitor Screen
The axis name set in the base axis specification parameter "#1022 axname2" appears at the axis name.
Display items
Droop (i) The error of the actual machine position to the command position is called droop. This
error is proportional to command speed value.
Speed (r/min) This displays the actual rotation speed of motor.
Feedrate (mm/s) This displays the feedrate detected by the detector mounted on the machine end.
Load current (%) This displays the FB value of the motor current in terms of continuous current during
stalling.
Max current 1 (%) This displays the motor current command in terms of continuous current during
stalling.
An absolute value of the current command peak value sampled after the power ON is
displayed.
Max current 2 (%) This displays the motor current command in terms of continuous current during
stalling.
An absolute value of the current command peak value sampled in most recent 2
seconds is displayed.
Max current 3 (%) This displays the FB value of the motor current in terms of continuous current during
stalling.
An absolute value of the current FB peak value sampled in most recent 2 seconds is
displayed.
Overload (%) This is the data used to monitor the motor overload.
Regen Load (%) This is the data used to monitor the resistance overload state when the resistance
regenerative power supply is connected.
Est disturb torq (%) This displays the estimated disturbance torque in terms of stall rated torque when the
disturbance observer is valid.
I - 377
5. Diagnosis Screens
5.4 Drive Monitor Screen
I - 378
5. Diagnosis Screens
5.4 Drive Monitor Screen
I - 379
5. Diagnosis Screens
5.4 Drive Monitor Screen
Display items
Droop (i) The error of the actual machine position to the command position is called droop. This
error is proportional to command speed value.
Speed (r/min) This displays the actual rotation speed of motor.
Load (%) This displays the motor load.
Max current 1 (%) This displays the motor current command in terms of continuous current during
stalling.
An absolute value of the current command peak value sampled after the power ON is
displayed.
Max current 2 (%) This displays the motor current command in terms of continuous current during
stalling.
An absolute value of the current command peak value sampled in most recent 2
seconds is displayed.
Max current 3 (%) This displays the FB value of the motor current in terms of continuous current during
stalling.
An absolute value of the current FB peak value sampled in most recent 2 seconds is
displayed.
Overload (%) This is the data used to monitor the motor overload.
Regen load (%) This is the data used to monitor the resistance overload state when the resistance
regenerative power supply is connected.
Est disturb torq (%) This displays the estimated disturbance torque in terms of stall rated torque when the
disturbance observer is valid.
Max disturb torq (%) This displays the estimated disturbance torque in terms of stall rated torque when the
collision detection function is adjusted.
An absolute value of the estimated disturbance torque peak value sampled in most
recent 2 seconds is displayed.
Load inertia R. (%) This displays the estimated load inertia ratio when the collision detection function is
adjusted.
I - 380
5. Diagnosis Screens
5.4 Drive Monitor Screen
I - 381
5. Diagnosis Screens
5.4 Drive Monitor Screen
Control input 2L This displays the control input signals from the NC.
I - 382
5. Diagnosis Screens
5.4 Drive Monitor Screen
Control input 4L This displays the control input signals from the NC.
Control input 4H Bit Details
0
1 Spindle control mode selection command 1, 2, 3
2
4L 3
4
5 Gear selection command 1
6 Gear selection command 2
7
8
9
A
4H B
C M-coil switch command
D L-coil switch command
E Sub-motor selection command
F
I - 383
5. Diagnosis Screens
5.4 Drive Monitor Screen
Control input 6L This displays the control input signals from the NC.
I - 384
5. Diagnosis Screens
5.4 Drive Monitor Screen
Control output 2L This displays the control output signals to the NC.
I - 385
5. Diagnosis Screens
5.4 Drive Monitor Screen
Control output 4L This displays the control output signals to the NC.
I - 386
5. Diagnosis Screens
5.4 Drive Monitor Screen
Control output 6L This displays the control output signals to the NC.
I - 387
5. Diagnosis Screens
5.4 Drive Monitor Screen
I - 388
5. Diagnosis Screens
5.4 Drive Monitor Screen
Display items
I - 389
5. Diagnosis Screens
5.4 Drive Monitor Screen
I - 390
5. Diagnosis Screens
5.4 Drive Monitor Screen
5.4.4 Display Items for the Auxiliary Axis Unit [700 series only]
"Auxiliary axis unit" appears only when there is one or more valid auxiliary axis. (Base common parameter
"#1044 auxno" is "1" or more).
The various data related to the auxiliary axis (MR-J2-CT) servo control is monitored.
For reference, change the display items using the key and key.
Data for the number of axes (up to six) set with the base common parameter "#1044 auxno (No. of connected
MR-J2-CT units)" is displayed.
Display items
I - 391
5. Diagnosis Screens
5.4 Drive Monitor Screen
I - 392
5. Diagnosis Screens
5.4 Drive Monitor Screen
Display items
I - 393
5. Diagnosis Screens
5.4 Drive Monitor Screen
Operation method
(3) Press the menu Alarm his clr . The menu is highlighted, and a message appears to
confirm the erasing.
The alarm history1: Time appears at the head.
(4) Press the Y key. The alarm history data for the selected axis (device) is
cleared to zero.
I - 394
5. Diagnosis Screens
5.5 NC Memory Diagnosis Screen (NC Memory Diagn Screen)
(1)
(2)
(3)
Display items
I - 395
5. Diagnosis Screens
5.5 NC Memory Diagnosis Screen (NC Memory Diagn Screen)
Menus
(Note) Decimal, hexadecimal, floating point data and character string data writing is possible.
Note that hexadecimal, floating point data and character strings may not be settable depending on the
data.
Decimal : Integers without decimal points ....... (Example) -1234
Hexadecimal : An "H" is necessary at the end........ (Example) 1234H
Floating point data : Data with a decimal point ................ (Example) -12.3
Character string data : Character string ............................... (Example) X
I - 396
5. Diagnosis Screens
5.5 NC Memory Diagnosis Screen (NC Memory Diagn Screen)
(1) Using the menu cursor keys, move the The cursor moves to the "Part system No." position.
cursor to the "Part system No." position.
(2) Set the part system No. The index No. is highlighted, and the set value is
displayed.
1 INPUT The cursor moves to the right item position.
(3) Separate the section No., sub-section No., The set value appears.
axis No. with a "/", and set. The cursor moves to the right item position.
126/8007/0 INPUT
(5) Set the data, and press the INPUT key. Write processing is executed.
The Index No. highlight returns to normal.
(2) Press the menu key Data read . The index No. highlight is released, and the normal
display of the memory data starts.
The data format (data size, display format) of the data
displayed in the memory data differs according to the
data type to be displayed.
(Note) The cursor is constantly displayed. Using the cursor keys, the cursor can be moved to the part system
No. area, section/sub-section/axis area.
I - 397
5. Diagnosis Screens
5.6 Alarm Screen
NC message
(1)
(2)
PLC message
(3)
(4)
I - 398
5. Diagnosis Screens
5.6 Alarm Screen
Display items
The axis name is displayed in messages for each axis. The axis name is displayed as shown below
according to the axis type.
Axis type Axis name display Display example Remarks
NC axis Control axis name XYZ If the same message occurs for each part system,
(Name of axis in part several NC axes are displayed together.
system)
Spindle 'S' + spindle No. S1S2 If the same message occurs, several spindles are
displayed together.
PLC axis 'P' + PLC axis No. P1P2 If the same message occurs, several PLC axes are
displayed together.
Auxiliary axis 'A' + auxiliary axis No. A1A2 If the same message occurs, several auxiliary axes
are displayed together.
If the same message occurs for different axis types, they will appear as separate messages.
The part system name is also displayed if the message is output for each part system. The part system name
set in "#1169 system name" is displayed. The part system name does not appear for the 1-part system.
I - 399
5. Diagnosis Screens
5.6 Alarm Screen
Record condition :When an alarm occurs (Up to five at the same time)
With multi-part system, 1st part system is given priority and recorded.
(Following 2nd part system, 3rd part system...)
Number of history :512 alarms (Whole)
Range of record :NC alarm (alarm, warning), stop code
I - 400
5. Diagnosis Screens
5.6 Alarm Screen
Menus
(Note 1) History start, History stop, History update and History clear menus are valid when the alarm history
function is valid and Alarm history menu is selected.
(Note 2) When the alarm history function is used for the first time, clear the alarm history contents by
pressing History clear menu. Unnecessary data may be recorded in the alarm history.
I - 401
5. Diagnosis Screens
5.7 Self Diagnosis Screen
(1) (3)
(2)
Display items
I - 402
5. Diagnosis Screens
5.7 Self Diagnosis Screen
I - 403
5. Diagnosis Screens
5.7 Self Diagnosis Screen
State Details
In-position This displays "1" (in-position state) when the following
conditions are satisfied for even one axis.
• No acceleration/deceleration delay for all axes
• Within the in-position width set in the parameter for all axes
Interlock(+) When the auto interlock +n-th axis signal or the manual
interlock +n-th axis signal is OFF, "1" appears for the n-th axis.
(Explanation of the display) oooooo1o
(3) Credit system This displays the valid term by the credit system when the credit system is valid.
This does not display when the credit system specification is invalid.
I - 404
5. Diagnosis Screens
5.7 Self Diagnosis Screen
Menus
(2) Press Y or INPUT . The cumulated count of the servo communication error
1 and 2 will be cleared to "0".
When other keys are pressed, it will not clear to "0".
This also applies to RIO clear , Ether clear and Battery clear menu.
When using the multi-part system specification, switch the displayed part system by Next system menu or
the part system switching key $⇔$ .
I - 405
5. Diagnosis Screens
5.8 Data Sampling Screen
(Note 1) The maximum number of sampled data items is the total number of data. When the number of
sampled channels is increased, the number of data per channel will decrease.
(1) (2)
(3)
(4)
Display items
Display State
Sampling Sampling is being executed.
Sampling stop Sampling is not being executed, or the sampling process has
completed.
Trigger wait When the "Start condition" is not set to "0" (manual start), this
indicates a state waiting for the sampling to start, detecting
the trigger, after the menu Samp start is pressed.
I - 406
5. Diagnosis Screens
5.8 Data Sampling Screen
(3) Sampling counter This displays the position of the sampling buffer during the sampling process.
When the sampling buffer is valid, the head of the buffer can be seen with the value of the
counter at the end of sampling.
Sampling buffer
0
1
:
n-1 End of buffer (newest data)
Sampling counter (n)→ n Head of buffer (oldest data)
:
(4) Sampling parameter This displays and sets the parameters necessary for sampling.
Menus
Sampling parameter
I - 407
5. Diagnosis Screens
5.8 Data Sampling Screen
0 Manual start
Sampling starts when Smp start menu is
pressed.
1 Variable No.
Sampling starts when the variable set in "Variable
No." is 0 or a value other than null. (Note 2)
2 PLC device
Sampling starts at the rising edge of the signal set
in "PLC device". (Note3)
3 Address condition, true
Sampling starts when "Address", "Data" and "Data
mask" conditions are true. (Note1)
4 Address condition, false
Sampling starts when "Address", "Data" and "Data
mask" conditions are false. (Note1)
Output form Select the data format when outputting the sampling data in text 0,1
style.
0 Outputs in decimal figure
1 Outputs in hexadecimal figure with 8 digits
(Note 1) When "Output form" is set to "1", and "#1004 ctlrunit" is
"E (1nano)", the data larger than 1m will not be output
correctly. When the output data exceeds 1m, the
low-order 32bits of the sampling data will be output.
(Note 2) Refer to the section "5.8.2 Outputting sampling data" for
details on sampling data output.
Address1 Set the sampling address. -
: (a) Index No. method
Address8 The index No. is fixed regardless of the axis configuration.
The low-order six digits of the address are explained below.
(If the high-order two digits are not set, the setting will be
interpreted as 00.)
I - 408
5. Diagnosis Screens
5.8 Data Sampling Screen
(Note) If a value other than "0" is set, the "End condition" must
also be set. If not, the sampling process will not end until it
is forcibly ended.
End condition Select the condition for ending the sampling process. (Note 4) 0 to 4
0 Sampling completed
When the buffer is full, the sampling ends.
1 Variable No.
Sampling ends when the variable set in "variable
No." is 0 or a value other than null (Note 2)
2 PLC device
Sampling ends at the rising edge of the signal set in
"PLC device". (Note 3)
3 Address condition, true
Sampling ends when "address", "data" and "data
mask" conditions are true. (Note 1)
4 Address condition, false
Sampling ends when "address", "data" and "data
mask" conditions are false. (Note 1)
I - 409
5. Diagnosis Screens
5.8 Data Sampling Screen
(Note) If both "Start condition" and "End condition" are set to other
than "1" (variable No.), the value will be ignored even if set.
PLC device This sets the PLC device that functions as the start/end trigger. (*)X0000 to (*)X1FFF
When "∗" is added at the head, the device will be a b contact. (*)Y0000 to (*)Y1FFF
If a device that does not exist is input or the device No. is not
within the setting range, an error will occur.
(Note) If both "Start condition" and "End condition" are set to other
than "2" (PLC device), the value will be ignored even if set.
Address This sets the address targeted for applying "Data mask". (Note 1) -
However, if an illegal address (highest-order bit 0) is input, an error
will occur.
(Note) If both "Start condition" and "End condition" are set to other
than "3" or "4" (address conditions, true/false), the value
will be ignored even if set. This item can be set with the
same methods as "address 1 to 8".
Data This sets the data for judging the results of applying "Data mask" -
on "Address".
(Note) If both "Start condition" and "End condition" are set to other
than "3" or "4" (address conditions, true/false), the value
will be ignored even if set.
Data mask This sets the data mask to be applied on "Address". -
(Note) If both " Start condition " and " End condition" are set to
other than "3" or "4" (address conditions, true/false), the
value will be ignored even if set.
(Note1) When "3" or "4" is set in "Start condition", be sure to set the address, the data, and the data mask.
This applies to "End condition" as well. If these are not set, sampling may not start.
When the same values are set in both "Start condition" and "End condition", sampling will not take a
place.
Example of "End condition" by setting address
Setting End condition :3
Address : 12345678
Data : 00000100
Data mask : 0000FFFF
Meaning of setting The trigger for sampling end turns ON when the results obtained by applying data
mask "0000FFFF" on the data of which address is "12345678" matches "00000100".
I - 410
5. Diagnosis Screens
5.8 Data Sampling Screen
(Note 2) When "1" is set in "Start condition"/"End condition", the common variable uses the floating decimal
point type. Thus, if the calculation results are used, an error will occur, and the value may not be
recognized as "0" because of its calculation error.
When using a multi-part system, the trigger will turn ON when the conditions are satisfied even if
only one part system is used.
(Note 3) The variable data settings are validated immediately only from the program. These will not be
validated immediately with settings from the screen or an external input.
(Note 4) Even if "End condition" is satisfied, the subsequent flow will differ according to the value set in
"Process type". (This also applies when ending manually.)
Sampling completed
Start trigger ON Start trigger ON End trigger ON
(buffer full)
One-shot
Sampling Sampling stopped
(2) Press the menu Samp start . The sampling starts and the menu cannot be selected.
When the sampling end condition is satisfied, the state
will be "Sampling stop". The menu Samp start can
be selected.
(Note 1) The sampling will not end even if transferred to another screen in sampling.
(Note 2) The data set in this function will not be output to the parameter.
(Note 3) The contents of "State" is returned to "Sampling stop". (The parameters related to NC data
sampling is maintained.)
(Note 4) The data is displayed in 16 digits. However, the data can be set up to 8 digits.
I - 411
5. Diagnosis Screens
5.8 Data Sampling Screen
Sampling can be output on the data I/O screen under [Mainte] tag.
(4) Press the menu Trnsfr A->B . Sampling file will be output.
(Note 1) The data can not be output when the sampling is not executed.
(Note 2) The data can be output only when the sampling output valid parameter (#1224 aux08/bit0) is
valid.
(Note 3) The output format differs depending on the sampling parameter "Output form".
(Note 4) The header information is not added to output sampling data.
I - 412
5. Diagnosis Screens
5.8 Data Sampling Screen
Sampling data is output in decimal figure when the sampling parameter "Output form" is set to "0".
(Example) When the number of channel is 3, the address is 1 to 3, and the output unit is E,
it stops when 1ch is 100mm, 2ch is -100mm and 3ch is 50mm.
Output format
1ch 2ch 3ch
1st data 200000000 -200000000 100000000
2nd data 200000000 -200000000 100000000
3rd data 200000000 -200000000 100000000
: : : :
Sampling data is output in hexadecimal figure with 8 digits when the sampling parameter "Output form" is set
to "1".
The output data is the sampling buffer dumped in the length of the long type data (32bits).
(Example) When the number of channel is 3, the address is 1 to 3, and the output unit is C,
it stops when 1ch is 100mm, 2ch is -100mm and 3ch is 50mm.
I - 413
5. Diagnosis Screens
5.9 Anshin-net Screen
Anshin-net connection status and message from NC service are displayed on this screen. Operator can make
one-touch calls; validate operator notification; and change the notifying party's telephone No.
(1)
(2)
(3)
(4) (5)
(6)
Display items
I - 414
5. Diagnosis Screens
5.9 Anshin-net Screen
Menus
I - 415
5. Diagnosis Screens
5.9 Anshin-net Screen
The notifying party's telephone No. and comments are set in this screen.
Anshin-net parameter 1
I - 416
5. Diagnosis Screens
5.9 Anshin-net Screen
(1) Set sampling condition and data. Notice Ope. menu key is highlighted and the other
menus will be disabled.
"Operator notice effective" is displayed.
When the Notice Ope. menu key is pressed again while operator notification is valid, menu's highlight
and disabled state will be canceled, and the operator notification will be disabled.
If machining ends normally/abnormally while operator notification is valid, system is connected to the NC
service.
("Dialing" → "Waiting for dialing" → "Verifying the user registration" → "Connecting" → "Sending" →
"Connecting" → "Transmission completed")
The message from NC service is displayed.
After data has been sent, menu's highlight and disabled state is canceled, and operator notification will
be disabled.
A call is made to the currently displayed notifying party's telephone No. from the call center.
(1) Press the Call menu key. Call menu is highlighted and the other menus will be
disabled.
"Carry out one-touch call? (Y/N)" is displayed.
(2) Press "Y" or the INPUT key. Connects to NC service. Connection status is displayed
in order.
("Dialing" → "Waiting for dialing" → "Verifying the user
registration" → "Connecting" → "Sending" →
"Connecting" → "Transmission completed")
Diagnosis data is sent to NC service after connection
has been established.
After diagnosis data has been sent, menu's highlight
and disabled state is canceled, and the message from
NC service is displayed.
(1) Press the 1-shot No. menu key. 1-shot No. menu is highlighted and the other menu will
be disabled.
The mode for setting the arbitrary No. is entered.
The cursor is displayed at the notifying party's
telephone No. column.
(2) Enter numerical value. Menu's highlight and disabled state are canceled, and
012-345-6789 INPUT "012-345-6789" is displayed at the cursor position.
The notifying party's telephone No. is changed to the
number entered.
If the 1-shot No. menu key is pressed again after an arbitrary telephone No. has been set, the
notifying party's telephone No. will be the number already selected (No. 1, 2, or 3).
(Note 1) If the No.1, No.2, or No.3 menu key is pressed after an arbitrary telephone No. has been input,
the displayed arbitrary telephone No. will be cleared and the notifying party's telephone No. will
be changed to the number 1, 2, or 3 on the Anshin-net parameter 1 screen.
I - 417
5. Diagnosis Screens
5.9 Anshin-net Screen
(1) Press the Anshin param.1 menu key in Anshin-net parameter 1 screen is displayed.
the message display screen. (Press the Anshin param.2 menu key to set the
parameter for Anshin-net parameter 2 screen.)
(2) Move the cursor to the item to be set with The cursor is moved to the item to be set, and the value
the and keys. currently set in the data setting area is displayed.
(3) Enter a value and press the INPUT The input value is reflected at the cursor position.
key.
I - 418
5. Diagnosis Screens
5.10 Machine Tool Builder Network System (MTB Net) Screen
Diagnosis data can be transmitted to the machine tool builder from this screen. The net connection state and
messages from the machine tool builder are also displayed on this screen.
(1)
(2)
(3)
(4)
Display items
I - 419
5. Diagnosis Screens
5.10 Machine Tool Builder Network System (MTB Net) Screen
Menus
MTB Jumps to the MTB net parameter1 screen. B "Setting the parameter"
param.1 (Note 1) This menu cannot be selected while connecting the
machine tool builder network.
Jumps to the MTB net parameter2 screen. B "Setting the parameter"
(Note 1) This menu can be used only when a password has been set
MTB
param.2 by the machine tool builder.
(Note 2) This menu cannot be selected while connecting the
machine tool builder network.
Warning This cancels the warning of network service. C "Canceling a warning of
cancel network service"
This transmits diagnosis information to the machine tool builder. A "Transmitting diagnosis
Send
information to the
machine tool builder"
I - 420
5. Diagnosis Screens
5.10 Machine Tool Builder Network System (MTB Net) Screen
The valid/invalid of the machine tool builder network (MTB net) function is set in this screen.
Menus
MTB Jumps to the MTB net parameter2 screen. B "Setting the parameter"
param.2 (Note 1) This menu can be used only when a password has been set
by the machine tool builder.
Return Jumps to the MTB net screen. C "Canceling a warning of
network service"
I - 421
5. Diagnosis Screens
5.10 Machine Tool Builder Network System (MTB Net) Screen
(1) Press the menu key Send. The Send menu will be highlighted, and the message
"Transmit diagnosis data? (Y/N)" will appear.
(2) Press "Y" or the INPUT key. Connects to the machine tool builder. Connection
status is displayed in order.
Diagnosis data is sent to the machine tool builder after
connection has been established.
After diagnosis data has been sent, menu's highlight is
canceled, and the message from the machine tool
builder is displayed.
(1) Press the menu key Warning cancel . The warning message from network service is cleared.
(Note 1) A warning message will appear if an error occurs when reception of the diagnosis results is
completed or during communication.
(Note 2) NC reset can also clear the warning message from network service.
(1) Press the MTB param.1 menu key in MTB net parameter 1 screen is displayed.
the message display screen. (Press the MTB param.2 menu key to set the
parameter for MTB net parameter 2 screen.)
(2) Move the cursor to the item to be set with The cursor is moved to the item to be set, and the value
the and keys. currently set in the data setting area is displayed.
(3) Enter a value and press the INPUT The input value is reflected at the cursor position.
key.
(Note 1) To return to the message display screen, Return key or CANCEL key is pressed.
(Note 2) When the communication between the call center and the machine tool builder is started while
displaying MTB net parameter screen 1 or 2, the parameters cannot be changed until the
communication is completed. The operation message "Network service is connected" appears.
I - 422
6. Maintenance Screens
6. Maintenance Screens
The NC memory can be formatted, the absolute position parameters setting, the SRAM backup, etc. are
possible on this screen. Important operations are protected with a password.
(1)
(3)
(2)
Display items
I - 423
6. Maintenance Screens
Menus
PLC This forcible stops the PLC ladder process. If this menu key is pressed C
stop in the stopped state, the stop is canceled.
All This backs up (saves) or restores (reloads) the file such as SRAM etc. C
backup to designated device.
Adjust This changes the screen to that for adjusting the spindle analog C
S-ana output.
To This sets the absolute position for servo axis (arbitrary NC axis, PLC C
Abs pos axis).
This carries out absolute position setting or test operation by the C
AUX
test auxiliary axis forward run/reverse run.
This menu is only for 700 series.
This executes the followings. C
Setting to collect the diagnosis data
Collect
set Confirming the diagnosis data collection status
Starting/Stopping to collect the diagnosis data
Clearing the diagnosis data
This formats the NC memory. B
Format
(1) Press the menu SRAM backup . A message appears to confirm the backup execution.
I - 424
6. Maintenance Screens
6.1 Parameter Screens
<Pattern 1> This is the screen for setting the common parameters for the axis, device, etc.
(Process param, etc.)
<Pattern 2> This is the screen for setting the parameters having an array structure for each axis
(Axis param, etc.)
I - 425
6. Maintenance Screens
6.1 Parameter Screens
<Pattern 3> This is the screen for setting parameters common for the axis and device, etc.
The parameter names are not displayed
(Machine error data, PLC constant, etc.)
<Pattern 4> This is the screen for setting parameters having an array structure for each part system
(Base system parameters, etc.)
I - 426
6. Maintenance Screens
6.1 Parameter Screens
<Pattern 5> This is the screen for setting the subprogram storage destination parameters
I - 427
6. Maintenance Screens
6.1 Parameter Screens
Menus
Control
param
Axis
param
Operate
param
Barrier
data
I/O
param
Ethernet
param
Link
param
Subpro
stor
I - 428
6. Maintenance Screens
6.1 Parameter Screens
Axis
spec
Zp-rtn
param
Abs pos
param
Servo
param
Spindle
spec
Spindle
param
RotAxis
param
PLC
timer
PLC inc
timer
PLC
counter
PLC
constnt
Bit
select
Er Comp
param
Er Comp
data
Macro
list
Posn
switch
AUX
param
Open
param1
Open
param2
CC-Link
param1
CC-Link
param2
I - 429
6. Maintenance Screens
6.1 Parameter Screens
(1) Press the menu change key until the menu The menu Link param appears.
Link param appears.
(2) Press the menu Link param . The computer link parameters appears.
The menu Link param is highlighted.
I - 430
6. Maintenance Screens
6.1 Parameter Screens
(2) Use the , , and keys to The cursor moves to the position of the setting target
data.
move the cursor to the position to be set.
The cursor can also be moved with the
menu Param No. .
Refer to "6.2.2 Selecting the parameter
No.".
(3) Input the value. The setting value appears, and the cursor moves.
1 INPUT
I - 431
6. Maintenance Screens
6.1 Parameter Screens
(2) Use the and keys to move the The cursor moves to the position of the setting target
data.
cursor to the position to be set.
(The row does not need to be designated
with the and keys.)
(3) Input the value. The setting value appears, and the cursor moves.
(Format: 1st row/2nd row/3rd row/4th row)
100//200 INPUT
(Note 1) If PR appears at the lower right of the screen when the parameter value is changed, the
parameter value will be validated when the power is turned ON again.
(Note 2) If the INPUT key is pressed without inputting a value, the cursor will move without changing the
parameter setting value.
(Note 3) If a character string, such as an axis name or input/output device name, is set in the parameter, the
setting will be cleared when 0 is input and the INPUT key is pressed.
(Note 4) Parameters for up to four rows, which are as currently displayed, can be set at once.
(Note 5) If the parameter value for several rows is input simultaneously, the values will be set from the
currently displayed left end no matter which row the cursor is currently at.
I - 432
6. Maintenance Screens
6.1 Parameter Screens
(2) Press the menu Area copy and The menu is highlighted.
INPUT . The setting value of the parameter at the cursor
position highlighted.
(Note) When the screen has an array structure for each axis or each part system, an error will occur if
different rows (axis or part system) are designated for the copy start position and end position.
I - 433
6. Maintenance Screens
6.1 Parameter Screens
(3) Designate the copy range. The copy target range is highlighted.
Format: First No./Last No. The menu highlight returns to normal.
8203/8205 INPUT
(Note 1) The copy target range highlight returns to the normal display by pasting. The copy target range is
valid until the parameter type display is changed.
(Note 2) Only the currently displayed parameter types can be copied.
(Example) If the parameter numbers #1001 to #1028 of the base system parameter are designated
as the copy target range, the base axis specification parameters #1013 to #1024 cannot
be copied.
(2) Press the menu key Area paste . The menu is highlighted, and a message confirming
the operation appears.
(3) Press Y or INPUT . The copied data is written to the parameter with the
same number as when copied, in the area where the
The copied data will not be written in when cursor is.
the N key is pressed. The menu highlight returns to normal.
(Note) If the corresponding parameter is changed after the copy target range is designated, the changed
value will be pasted.
I - 434
6. Maintenance Screens
6.1 Parameter Screens
(Note 1) This is valid only when the total number of valid NC axes and PLC axes in the entire part system is
five or more.
(Note 2) This is valid only when the total number of valid NC axes and PLC axes in the entire part system is
two or more.
(Note 3) This is valid only when the number of valid part systems is two or more.
(Note 4) The barrier data appears only for the L specifications.
(2) Input F , and press the INPUT key. "FD" appears at "#8882 D1: dev".
The cursor moves down one line.
(2) Set "/TEMP1/TEMP12/TEMP123", and The value is set, and the cursor moves down one line.
press the INPUT key.
I - 435
6. Maintenance Screens
6.1 Parameter Screens
I - 436
6. Maintenance Screens
6.2 Input/Output Screen
(1)
(2)
(4)
(3) (5)
(6)
(7)
Display items
I - 437
6. Maintenance Screens
6.2 Input/Output Screen
* : When the Ethernet parameter "#97*1 Host n no total siz" is set to 1, the number of host memory
characters will not appear.
I - 438
6. Maintenance Screens
6.2 Input/Output Screen
Menus
I - 439
6. Maintenance Screens
6.2 Input/Output Screen
I - 440
6. Maintenance Screens
6.2 Input/Output Screen
Designate the device where the target file is located. → Select from the sub menu.
↓
Designate the directory with a full path. → Input the full path or select from the list.
↓
Designate the file name. → Input the file name or select from the list.
Menu used
I - 441
6. Maintenance Screens
6.2 Input/Output Screen
Designation method
Device Designation target file
Device Directory File name
NC memory • Machining program Select from the - Key input in the input
• User macro submenu (Default) area, and press INPUT
• Fixed cycle
Select from the list
Other than the Select from the Key input in the input area, -
machining program submenu and press INPUT (Fixed)
Select from the submenu
Other than the All Select from the Key input in the input area, Key input in the input
NC memory submenu and press INPUT area, and press INPUT
Select from the list Select from the list
The device can be selected from the submenu. (The devices that can be used will differ depending on the
specifications.)
One of the following methods can be used to designate the directory (for devices other than the NC memory)
and file name.
• Set the directory path (full path) or file name in the input area, and press the INPUT key.
• Press submenu From list of the menu Dir or File name . Move the cursor to the target directory or
file name, and press the INPUT key.
A wild card (*) can be used when selecting a file name.
(1) During directory and file name setting, the designated directory, path or file name will be set, even if it
does not actually exist. This will not cause an error. Note that the previously set directory is overwritten.
(2) When a file in the NC memory other than a machining program is designated, it is not necessary to set
the file name. (The file name is fixed.)
(3) When a file name is selected from the menu, it first is displayed in the input area. However, at this time
the file name has not yet been fixed. Press the INPUT key again to fix the file name.
(4) When the key is pressed when setting a file name, the file name in the input area is erased.
(5) When a fixed cycle program is designated, the basic common parameters "#1166 fixpro" must be set.
Select "Memory" for the device, and "Program" for the directory.
I - 442
6. Maintenance Screens
6.2 Input/Output Screen
(1) Press the menu Device select . The following menu appears.
(2) Press the menu Memory . "Memory" appears in the device name, and the default
"Program" appears in the directory.
(3) Press the menu File name . The following menu appears.
(4)-2 Move the cursor to file name to be The selected file name appears in the input area.
selected, and fix.
, , INPUT
(4)-3 Press the INPUT key. The selected file name appears.
I - 443
6. Maintenance Screens
6.2 Input/Output Screen
(1) Press the menu Device select . The following menu appears.
(2) Press the menu Memory . "Memory" appears in the device name, and "Program"
appears as the default in the directory.
(4) Press the menu Tool offset . The directory and file name appear.
(Note) The file name for each directory is fixed. Refer to "6.2.10 List of file names" for the file names.
I - 444
6. Maintenance Screens
6.2 Input/Output Screen
(1) Press the menu Device select . The following menu appears.
(2) Select a device. The device name appears. The root directory is
selected as the default.
(3) Designate the directory. The mode changes to the mode for inputting the
Select the menu Dir directory name.
The following menu appears.
/PRG/PRECUT INPUT
(4)-2 Move the cursor to directory to be The selected directory appears in the data setting
selected, and fix. column.
The contents of the selected directory appear in the
, , INPUT list.
I - 445
6. Maintenance Screens
6.2 Input/Output Screen
(5) Designate the file name. The mode changes to the mode for inputting the file
Press the menu File name name.
The following menu appears.
10013.PRG INPUT
(6)-2 Move the cursor to file name to be The selected file name appears in the input area.
selected, and fix.
, , INPUT
(6)-3 Press the INPUT key. The selected file name appears.
I - 446
6. Maintenance Screens
6.2 Input/Output Screen
(2) Press the key. The details in the input area are erased, and the main
menu appears.
Main menu
The details in the data input area are erased.
Submenu
I - 447
6. Maintenance Screens
6.2 Input/Output Screen
Operating method
(2) Designate the transfer origin device, The designated file appears.
directory and file name. Multiple files can be designated in the file setting
column A. Designate the first and last file name of the
target range. A wildcard "*" can be designated for the
file name.
(4) Designate the transfer destination device, The designated file appears.
directory and file name.
(5) Press the menu Trnsfr A ->B . A message appears to confirm the transfer.
(6) Press Y or INPUT . The file transfer starts. The data being transferred
appears in the input data display column.
A message appears when the transfer is completed.
! Caution
! " ; ", "EOB", "%", and “EOR” are symbols used for explanation. The actual codes for ISO are "CR,
LF" ("LF") and "%".
The programs created on the Edit screen are stored in the NC memory in a "CR, LF" format,
however, the programs created with external devices such as the FD or RS-232C may be stored in
an "LF" format.
The actual codes for EIA are "EOB (End of Block)" and "EOR (End of Record)".
! To prevent the influence of data loss and data transformation over the line, always carry out data
comparison after transferring a machining program.
I - 448
6. Maintenance Screens
6.2 Input/Output Screen
Notes
I - 449
6. Maintenance Screens
6.2 Input/Output Screen
(7) Notes when transferring auxiliary axis parameter files (700 series only)
(a) When the auxiliary axis parameters are input to the NC memory, the same parameter data is
simultaneously transferred to the drive unit. If transferred errors by some causes occur, the
parameter data may be not matched between NC memory data and drive unit.
Operation method
(2) Designate the device, directory and file The designated file name appears.
name to be compared.
(4) Designate the other side device, directory The designated file name appears.
and file name to be compared.
(5) Press the menu Compare A:B . The file comparison starts. The data being compared
appears in the comparison data display column.
A message appears when the comparison is
completed.
If a comparison error occurs, the block with the error is
displayed in the comparison data display column on
the screen.
I - 450
6. Maintenance Screens
6.2 Input/Output Screen
(2) Designate the device, directory and file The designated file appears.
name to be erased.
(3) Press the menu Erase A . A message to confirm the erasing appears.
(Note) If the file to be erased is running or in "program restarting" mode, the operation message "Executing
automatic operation" or "Program restarting" is displayed, and the file will not be erased.
The operations are the same as method "Erasing a file Erase A " above. Designate the target device,
directory and file name in the file setting column B, and press the menu Erase B .
Operation method
(2) Designate the original device, directory The designated file name appears.
and file name.
(4) Designate the new device, directory and The designated new file name appears.
file name.
(Note 1) Select the same device for original and new devices.
(Note 2) If the file to be renamed is running or in "program restarting" mode, the operation message
"Executing automatic operation" or "Program restarting" is displayed, and the name will not be
changed.
(Note 3) If a file that does not exist is designated for the original file, or if an existing file name is designated
for the new file selection, an error occurs, and the name is not changed.
I - 451
6. Maintenance Screens
6.2 Input/Output Screen
Operation method
(3) Designate the directory where the new The designated details appear.
directory is to be created.
(4) Set the new directory in file setting column The designated details appear.
A.
(5) Press the menu Dir create . The designated directory is created.
I - 452
6. Maintenance Screens
6.2 Input/Output Screen
Operation method
(2) Designate the merge destination device, The designated file name appears.
directory and file name.
(4) Designate the merge origin device, The designated file name appears.
directory and file name.
(5) Press the menu Merge B ->A . A message confirming the merge appears.
(6) Press Y or INPUT . The file merge starts. The data being merged will appear in
the Input Data display column.
A message appears when the merge is completed.
(Note 1) If the merge destination file (file in file setting column A) is running or in "program restarting" mode,
the operation message "Executing automatic operation" or "Program restarting" is displayed, and
the files will not be merged.
(Note 2) The devices that can be merged are the memory, HD, FD, memory card and DS.
I - 453
6. Maintenance Screens
6.2 Input/Output Screen
(1) Insert a floppy disk in the FD drive, and A message confirming the formatting appears.
press FD format .
(1) Press the menu MemCrd format . A message confirming the formatting appears.
First, press the menu DS format . Refer to "Formatting a memory card" for following operations.
(Note 1) The DS is formatted with FAT16.
(Note 2) Only the DS formatted with FAT16 can be used. The DS with NTFS cannot be used.
(Note 3) As for the DS formatted with NTFS, reformat it with FAT formatted by Windows to use.
(NC cannot convert NTFS partition to FAT formatted.)
(Note 4) The volume label is not set even when the DS is formatted.
I - 454
6. Maintenance Screens
6.2 Input/Output Screen
The following types of data format are used according to parameter type and display method.
(The address order in one block must use the following format.)
N1084P0.001
(a) The output parameter setting value is the same format as the screen display.
N2001A1P10000
Parameter setting value
Axis No. 1 to 4
Parameter # No.
I - 455
6. Maintenance Screens
6.2 Input/Output Screen
N1001T1P1
Parameter setting value
Part system No. (1: $1, 2: $2, 3: PLC axis)
Parameter # No.
(a) The parameter data for the screen in which parameters per part system are displayed on one screen
is out put as follows.
[Output example]
:
N1001T1P1
N1001T2P1
N1001T3P0
N1002T1P2
N1002T2P1
N1002T3P0
:
(b) If parameters are displayed per part system upon switch of the part system (when $ key is
pressed), the parameter data is output per part system.
[Output example]
:
N8001T1P99
N8002T1P0
N8003T1P10000
:
N8001T2P30
N8002T2P1
N8003T2P20000
:
I - 456
6. Maintenance Screens
6.2 Input/Output Screen
N13001C1P100
Parameter setting value
Spindle No. 1 to 4
Parameter # No.
(5) IP address
N1926K1P192
[Output example]
(Example) When "#1926 Global IP address" setting value is "192.168.200.1"
:
N1926K1P192
N1926K2P168
N1926K3P200
N1926K4P1
:
I - 457
6. Maintenance Screens
6.2 Input/Output Screen
(1) M type
Tool compensation amount data format is as follows.
Address Definition Details
G - Fixed to G10.
L Type L10 for tool compensation memory I.
See below for tool compensation memory II.
L10:Tool length shape compensation
L11:Toll length wear compensation
L12:Tool radius shape compensation
L13:Tool radius wear compensation
P Compensation No. The compensation No. is shown with the value following P.
R Compensation amount The compensation No. is shown with the value following R.
[Output example]
%
$1
G10L10P1R0.000
G10L10P2R0.000
:
$2
G10L10P1R0.000
G10L10P2R0.000
:
%
(2) L type
Tool compensation amount data format is as follows.
Address Definition Details
G - Fixed to G10.
L Type L10 for tool length compensation input.
L11 for tool nose wear compensation input.
P Compensation No. The compensation No. is shown with the value following P.
X X axis compensation The X axis compensation amount data is shown with the value
amount (Absolute) following X. (Absolute)
U X axis compensation The X axis compensation amount data is shown with the value
amount (Incremental) following U. (Incremental)
Z Y axis compensation The Y axis compensation amount data is shown with the value
amount (Absolute) following Z. (Absolute)
W Y axis compensation The Y axis compensation amount data is shown with the value
amount (Incremental) following W. (Incremental)
R Nose R compensation The nose R compensation amount data is shown with the
amount (Absolute) value following R. (Absolute)
C Nose R compensation The nose R compensation amount data is shown with the
amount (Incremental) value following C. (Incremental)
Q Hypothetical tool nose The hypothetical tool nose point is shown with the value
point following Q.
[Output example]
%
G10L10P1X0.000Z0.000R1.000Q3
G10L11P1X0.000Z0.000R0.000Q3
G10L10P2X0.000Z0.000R1.000Q2
:
G10L11P80X0.000Z0.000R0.000Q0
%
I - 458
6. Maintenance Screens
6.2 Input/Output Screen
(1) M type
Tool life management data format is as follows.
Address Definition Details
G Group No. The group No. for tool life management is shown with the
value following G.
D Tool no. The tool No. is shown with the value following D.
S Status The tool status is shown with the value following S.
M Method The tool life management method is shown with the value
following M.
L Length compensation The length compensation data is shown with the value
following L.
R Radius compensation The radius compensation data is shown with the value
following R.
B AUX. The auxiliary data is shown with the value following B.
E Service lifetime The service lifetime is shown with the value following E.
P Used time The used time is shown with the value following P.
[Output example]
%
LIFEDM()
$1
G100 D1000 S1 M101010 L100 R100 B11 E0 P0
G200 D2000 S2 M000000 L200 R200 B22 E0 P0
G300 D3000 S3 M201020 L300 R300 B33 E0 P0
:
G999999 D9999 S1 M202020 L999 R999 B99 E0 P0
%
(2) L type
(a) Tool life management I
Tool life management I format is as follows.
Address Definition Details
N Tool No. The tool No. is shown with the value following N.
P Time-used The time-used is shown with the value following P.
E Time-max The time-max is shown with the value following E.
Q Count-used The count-used is shown with the value following Q.
F Count-max The count-max is shown with the value following F.
S Status The status of tool life management is shown with the value
following S.
B AUX. The auxiliary data is shown with the value following B.
[Output example]
%
LIFEL1( TOOL LIFE DATA)
$1
N1 P12.34.56 E45.56 Q6 F7 S1 B0
N2 P2.3.4 E5.6 Q7 F8 S1 B1
N3 P99.59.59 E99.59 Q9999 F9999 S2 B99
N4 P0.0.0 E0.0 Q0 F0 S0 B0
:
N80 P0.0.0 E0.0 Q0 F0 S0 B0
%
I - 459
6. Maintenance Screens
6.2 Input/Output Screen
I - 460
6. Maintenance Screens
6.2 Input/Output Screen
[Output example]
%
LIFEL2( TOOL LIFE DATA)
$1
G100 M0 E1000 A50 D123456 H1 P321 S1
G100 M0 E1000 A50 D888888 H2 P0 S0
G111 M1 F2000 B80 D777777 H20 Q2000 S2
G1234 M0 E1000 A50 D123 H30 P100 S1
G9999 M1 F999999 B9 D999999 H80 Q999999 S2
%
[Output example]
%
COMN()
N100T1P123.0000
N101T1P1.0000E7
:
N100T2P1.0000E7
:
%
I - 461
6. Maintenance Screens
6.2 Input/Output Screen
[Output example]
I - 462
6. Maintenance Screens
6.2 Input/Output Screen
Machining program A
1 to 7999
Machining program B
(user standard subprogram)
8000 to 8999
Machining program C Editing Editing
(machine tool builder custom prohibited by prohibited by
program) Edit lock C Edit lock B
9000 to 9999
Machining program A
10000 to 99999999
The operations below in the Edit MDI and the Input/Output screens are influenced by the edit lock setting.
An error will result if operations that are not possible are attempted.
When the edit lock is valid, processing is executed (except the edit lock target program) by the input/output
function.
I - 463
6. Maintenance Screens
6.2 Input/Output Screen
(1) KEY1: Provides general protection for tool data and protection of the coordinate system preset using
the origin set.
(2) KEY2: Protects user parameters and common variables.
(3) KEY3: Protects the machining program.
Data settings and deletion is stopped if any of the data protection keys is OFF.
(Note 1) When using the multi-part system, the settings for various types of data in all part systems are
prohibited with the data protection keys.
The operations listed in the table below are prohibited when KEY 1 is OFF.
<Data protected by KEY1 >
No. Operation Screen
1 Origin set Monitor
2 Tool compensation amount setting/erasing Tool compensation amnt, Tool measure
3 Tool registration data setting/erasing Tool registration
4 Tool life data setting/erasing Tool life
5 Workpiece coordinate offset amount setting/erasing Coord offset, Workpiece measure, Rotate meas
6 Tool offset data input/output Input/Output
7 Tool compensation amount input/output Input/Output
8 Tool registration data input/output Input/Output
9 Tool life data input/output Input/Output
10 Workpiece coordinate offset amount input/output Input/Output
(Note) If setting of data in the screens shown in No. 2 to 5 is attempted when the KEY1 is OFF, the message
"Data protect" appears.
If origin set is attempted on the Position display1 screen and the INPUT key is pressed, the origin
set is not executed, and the message "Origin set not possible" appears.
If the operations shown in No. 6 to 10 are attempted and the INPUT key is pressed, the message
"Data protect" appears, and the input and output are disabled.
I - 464
6. Maintenance Screens
6.2 Input/Output Screen
The operations listed in the table below are prohibited when KEY 2 is OFF.
<Data protected by KEY 2>
No. Operation Screen
1 Control parameter ON/OFF Setup/User/Control param
2 Axis parameter setting Setup/User/Axis param
3 Operation parameter setting Setup/User/Operation param
4 Machining parameter setting Setup/User/Process param, Rotate meas
5 Common variable setting Monitr/Position display/Common variable
6 I/O basic parameter setting Mainte/Parameter
7 Parameter input/output Mainte/I/O
8 Common variable input/output Mainte/I/O
(Note) If setting of data in the screens shown above is attempted when the KEY2 is OFF, the message "Data
protect" appears.
If the operations shown in No. 7 and 8 are attempted and the INPUT key is pressed, the message
"Data protect" appears, and the input and output are disabled.
The operations listed in the table below are prohibited when KEY 3 is OFF.
<Data protected by KEY3>
No. Operation Screen
1 MDI data memory entry MDI
2 Machining program editing Edit
3 New program editing Edit
4 Registered program comment setting Edit
5 Machining program memory registration, compare, input/output Input/Output
6 Machining program erasing (single, all) Input/Output
7 Registered program comment setting Input/Output
8 Machining program copy, marge, name change Input/Output
9 Machining program buffer correction Monitr
(Note) If editing or setting, etc., is attempted on the screens shown above when the KEY3 is OFF, the
message "Data protect" appears.
I - 465
6. Maintenance Screens
6.2 Input/Output Screen
Operation method
(2) Designate the transfer source device, The designated file appears.
directory and file name.
(4) Press the menu Anshin net to "Anshin-net server" is displayed as device name.
designate the transfer destination device The file name, unless specified, is as same as the
and file name. name of the originally transferred file.
Only numbers within 10 characters can be used for
a file name.
(5) Press the menu Transfr A→B . A message appears to confirm the transmission of
machining data.
(Note 1) Neither HD operation nor memory card operation can be performed during file transmission from
HD.
(Note 2) Only one file can be saved on Anshin-net server. The file previously exists on the Anshin-net server
is overwritten.
(Note 3) Anshin-net icon appears in the upper middle of the screen during Anshin-net communications.
(Note 4) When Anshin-net server is specified as device name, the directory button is displayed in gray and
cannot be selected.
I - 466
6. Maintenance Screens
6.2 Input/Output Screen
(2) Press the menu Anshin net to “Anshin-net server” as device name and the
designate the transfer source device and designated file name are displayed.
file name.
(5) Designate the transfer destination device, The designated file appears.
directory and file name.
(6) Press the menu Transfr A→B . A message appears to confirm the reception of
machining data.
When the file name is not designated in the file setting
column A, the message “File name not designated for
dev A” appears to indicate the error.
(7) Press the Y or INPUT key. The reception of machining data starts.
A message appears upon the completion of reception.
(Note 1) When the same file name exists in the transfer destination device, an error occurs and the transfer
cannot be executed.
(Note 2) Anshin-net icon appears in the upper middle of the screen during Anshin-net communications.
(Note 3) When Anshin-net server is specified as device name, the directory button is displayed in gray and
cannot be selected.
I - 467
6. Maintenance Screens
6.2 Input/Output Screen
(2) Press the menu Anshin-net to “Anshin-net server”, as device name, and the
designate the file name to erase. designated file name are displayed.
(3) Press the menu Erase A . A message appears to confirm the erasing.
(1) Press the menu key Warning cancel . The warning message from network service is cleared.
(Note 1) A warning message from network service appears when any error occurs during communications.
(Note 2) NC reset can also clear the warning message from network service.
Notes
I - 468
6. Maintenance Screen
6.3 All Backup Screen
(1)
(2)
(3)
(4)
(5)
Display items
I - 469
6. Maintenance Screen
6.3 All Backup Screen
Menus
I - 470
6. Maintenance Screen
6.3 All Backup Screen
Operation methods
(2) Move the cursor to select the area. An operation message "OK? (Y/N)" appears.
Press the INPUT key. (Note) Auto 1 to 3 cannot be selected.
Operation methods
(2) Move the cursor to select the file. An operation message "OK? (Y/N)" appears.
Press the INPUT key.
I - 471
6. Maintenance Screen
6.4 System Setup Screen
(1)
(2)
(5)
(3)
(4)
Display items
I - 472
6. Maintenance Screen
6.4 System Setup Screen
I - 473
6. Maintenance Screen
6.4 System Setup Screen
Menus
Operation methods
(1) Save the spindle parameter setting file at the Assuming that personal computer recognizes the
memory card's root directory. memory card as the E drive, the spindle parameter
setting file is saved as "E: \INITSP.PRM".
(2) Insert the memory card into the front IC card At the input/output screen, verify that the
holder. "INITSP.PRM" file has been saved on the memory
card.
I - 474
6. Maintenance Screen
6.4 System Setup Screen
Operation methods
(3) Press the Y or INPUT key. Parameter setting begins, and an operation
message appears as follows.
"Initial parameter creating" → "Initial parameter
transferring" → "Spindle initial parameter
transferring" (This operation message is
displayed only if a spindle parameter setting file
exists.)
When parameter settings are completed, an
operation message "Param set ended. Format
NC memory? (Y/N)" appears.
(4) Press the Y or INPUT key. File formatting begins, and an operation message
"Executing format" appears.
When file formatting is completed, an operation
message "Format complete" appears.
(Note 1) When the "data protect key 2" is enabled, an operation message "Data protect" appears, and
processing is interrupted.
(Note 2) In the automatic operation mode, an operation message "Executing automatic operation" appears,
and processing is interrupted.
(Note 3) If all the required settings have not been input on the system setup screen, an operation message
"Setting error" appears, and processing is interrupted.
(Note 4) Processing is interrupted if a key other than the Y or INPUT key is pressed, or if switching to
another screen occurs. (Processing is interrupted even if switching to another screen occurs during
data transfers.)
(Note 5) The menu is displayed in gray during data transfers.
I - 475
6. Maintenance Screen
6.4 System Setup Screen
Operation methods
(1) Press the menu Ladder setting . An operation message "Write sample ladder?
(Y/N)" appears.
(2) Press the Y or INPUT key. Sample PLC ladder writing begins, and an
operation message "Transferring" appears.
When sample PLC ladder writing is completed, an
operation message "Transfer complete" appears.
(Note 1) In the automatic operation mode, an operation message "Executing automatic operation" appears,
and processing is interrupted.
(Note 2) In the "PLC RUN" mode, an operation message "PLC running" appears, and processing is
interrupted.
(Note 3) If there is no sample PLC ladder, an operation message "Sample ladder not found" appears, and
processing is interrupted.
(Note 4) Processing is interrupted if a key other than the Y or INPUT key is pressed, or if switching to
another screen occurs. (Processing is interrupted even if switching to another screen occurs during
data transfers.)
(Note 5) The menu is displayed in gray during data transfers.
I - 476
6. Maintenance Screen
6.5 Adjust S-analog Screen
(1)
(2)
(5)
(3)
(4)
Display items
I - 477
6. Maintenance Screen
6.5 Adjust S-analog Screen
Menus
I - 478
6. Maintenance Screen
6.5 Adjust S-analog Screen
Operation methods
The PLC must be stopped when performing spindle analog output adjustments.
(1) Press the function key MAINTE . The maintenance screen appears.
(3) Enter the machine tool builder password. The menu highlighting is cleared.
Automatic adjustment will execute "0V offset adjustment" and "+ gain adjustment" for the remote I/O analog
outputs (max. 4ch) connected to the main unit. The - gain will be handled as the + gain.
Operation methods
(2) Press the Y or INPUT key. Automatic adjustment begins, and an operation
message "Auto adjust execution" appears.
The manual adjustment related menu is displayed
in gray during the automatic adjustment, and
manual adjustments are disabled.
Switching to other screens is also disabled at this
time.
When the automatic adjustment is completed, an
operation message "Auto adjust complete"
appears.
I - 479
6. Maintenance Screen
6.5 Adjust S-analog Screen
(1) Use the ↑ ↓ keys to move the cursor to The menu and the selected line are highlighted.
item #10101, then press the Manual adjust The current setting value is displayed at "Current
menu button. adjust data". A 0V analog voltage is output to ch0
at this time.
(2) Monitor the analog voltage. Adjust the 0V offset until the analog voltage is 0V
±3.5mV. The setting range -999 to 999.
(4) Press the INPUT key. "Current adjust data" is set as "ch0 0V offset", and
the 0V offset result is enabled.
The menu Manual adjust highlighting is
cleared.
I - 480
6. Maintenance Screen
6.5 Adjust S-analog Screen
(1) Use the ↑ ↓ keys to move the cursor to The menu and the selected line are highlighted.
item #10102, then press the menu The current setting value is displayed at "Current
Manual adjust . adjust data". A ch0 +10V analog voltage is output
at this time.
(2) Monitor the analog voltage. Adjust the + gain until the monitor voltage is 10V
±3.5mV. The setting range -999 to 999.
(4) Press the INPUT key. "Current adjust data" is set as "ch0 + gain", and
the adjustment result is enabled.
The menu Manual adjust highlighting is
cleared.
(1) Use the ↑ ↓ keys to move the cursor to The menu and the selected line are highlighted.
item #10103, then press the menu The current setting value is displayed at "Current
Manual adjust . adjust data". A ch0 -10V analog voltage is output
at this time.
(2) Monitor the analog voltage. Adjust the - gain until the monitor voltage is -10V
±3.5mV. The setting range -999 to 999.
(4) Press the INPUT key. "Current adjust data" is set as "ch0 - gain", and
the adjustment result is enabled.
The menu Manual adjust highlighting is
cleared.
I - 481
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(1)
(8) (2)
(3)
(4)
(5)
(6)
(7)
Display items
I - 482
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(Note) [Type of zero point initialization] indicates the progress state of zero point initialization as shown below.
1.Dogless-type absolute position detection system
Machine end stopper method (manual initialization)
Order Display Details of progress
1 Illegality While the absolute position is lost.
2 Stopper From when the menu "Abs pos set" is pressed
to when the axis pushes against the machine end stopper.
3 Release From when the axis pushes against the machine end stopper
to when axis starts to move in the counter direction.
4 Ret. Ref. P. From when the axis moves in the counter direction
to when it reaches the grid point immediately before the stopper.
5 Complete The axis has reached the grid point immediately before the stopper.
The absolute position has been established.
2. Dogless-type absolute position detection system
Machine end stopper method (automatic initialization)
Order Display Details of progress
1 Illegality While the absolute position is lost.
2 Jog Start From when the menu "Abs pos set" is pressed
to when a value is set in "Zero-P".
3 Stopper1 From when JOG operation starts
to when the axis pushes against the machine end stopper.
4 Zero-P. Rel. From when the axis pushes against the machine end stopper
to when axis reaches the approach point.
5 Stopper2 From when the axis reaches the grid point immediately before the stopper
to when it pushes against the machine end stopper.
6 Ret. Ref. P. From when the axis pushes against the machine end stopper second time
to when axis reaches the grid point immediately before the stopper.
7 Complete The axis has reached the grid point immediately before the stopper.
The absolute position has been established.
3. Dogless-type absolute position detection system
Marked point alignment method
Order Display Details of progress
1 Illegality While the absolute position is lost.
2 Origin Set From when the menu "Abs pos set" is pressed
to when "1" is set in "Origin-P".
3 Ret. Ref. P. While moving in the direction designated with the absolute position parameter #2050.
4 Complete The axis has reached the grid point immediately before the marked point.
The absolute position has been established.
4. Dogless-type absolute position detection system
Marked point alignment method II
Order Display Details of progress
1 Illegality While the absolute position is lost.
2 Origin Set From when the menu "Abs pos set" is pressed
to when "1" is set in "Origin-P".
3 Complete With the sequence above, the absolute position is established.
5. Dog-type absolute position detection system
Order Display Details of progress
1 Illegality While the absolute position is lost.
2 Zero-P. Rel. After dog-type manual or automatic reference position return is started.
3 Complete Axis has returned to the reference position.
I - 483
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
Menus
Procedures
(2) Set the axis name (which was set with The axis name and data change.
"#1022 axname2") and press INPUT key. Procedures displays according to the selected initialization
type.
I - 484
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(1) Select the axis that "#2049 type" is "1". Refer to "6.6.1 Selecting the Axis" for procedures to select
the axis.
(3) Input "1" to "Absolute posn set". The input value appears at "Absolute posn set".
(4) Input an arbitrary value to "#2 Zero-P". The input value appears at "#2 Zero-P".
(5) Move the axis toward the machine end State : [Stopper]
stopper. Machine end : Distance between stopper and grid point
-> a
Machine posn : [Not passed] -> current machine position
The current has reached its limit for given State : [Release]
time.
-> c
(7) Move the axis in the counter direction. State : [Ret. Ref. P.]
-> d
I - 485
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
If "#2059 zerbas" is "0" (absolute position origin point = mechanical basic position), axis will stop
automatically at this point without moving in the opposite direction and "Complete" appears at [State] and
"0.000" at [Machine end].
(8) (7)
Basic machine coordinate system Reference (9)
zero point position
(Note1) To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P",
and then turn the power OFF and ON.
(Note2) If pressing against the machine end is attempted without passing the grip point once after turning
the power ON, the operation message "Not passed on grid" will appear. Return to a point before the
last grid, and then repeat from step of pressing against the machine end stopper.
(Note3) If the first grid point is covered by the grid mask (#2028 grmask) as a result of return to the electric
basic position, the axis stops at the next grid point.
Note that zero-point shift amount (#2027 G28sft) is invalid.
I - 486
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(3) Input "1" to "Absolute posn set". The input value appears at "Absolute posn set".
(4) Input an arbitrary value to "#2 Zero-P". The input value appears at "#2 Zero-P".
The axis pushes against the machine end State : [Zero-P. Rel.]
stopper. After the current reached its limit
for given time, the axis returns toward the
approach point at the "push speed".
-> b
The axis pushes against the machine end State : [Ret. Ref. P.]
stopper. After the current reached its limit
for given time, the axis returns toward the
grid point immediately before the stopper
at the "push speed".
-> d
I - 487
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
If "#2059 zerbas" is "0" (absolute position origin point = mechanical basic position), axis will stop
automatically at this point without moving in the opposite direction and "Complete" appears at [State] and
"0.000" at [Machine end].
Grid point
(electric basic "Machine end"
position) Machine end stopper
Reference position (mechanical basic
parameter position)
"#2037 G53ofs" "#2056 aproch"
(Note1) To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P",
and then turn the power OFF and ON.
(Note2) If pressing against the machine end is attempted without passing the grip point once after turning
the power ON, the operation message "Not passed on grid" will appear. Return to a point before the
last grid, and then repeat from step of pressing against the machine end stopper.
(Note3) If the first grid point is covered by the grid mask (#2028 grmask) as a result of return to the electric
basic position, the axis stops at the next grid point.
Note that zero-point shift amount (#2027 G28sft) is invalid.
(Note4) Acceleration/deceleration during movement at the specified push speed is performed in
smoothing-off (step feed) mode.
(Note5) If "0" is specified for "#2056 aproch" of the absolute position parameters, the machine zero point is
regarded as the approach point.
(Note6) Automatic initialization is interrupted if one of the following events occurs. If it is interrupted, [State]
indicates "Jog Start" (after selecting the "Auto init set" mode if it is caused by mode change), so
restart operation from the step of JOG-start.
• An absolute position detection alarm occurs.
• Operation preparation signal turns OFF.
• The mode is changed.
• The system is reset.
If [State] is "Complete" before automatic initialization is started, "State" returns to "Complete" when
power is turned OFF and ON again without restarting the operation.
I - 488
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(Note7) Automatic initialization cannot be started in the following cases. The operation message "Can't
start" will appear if starting is attempted.
• When "#0 Absolute posn set" is not set.
• When the "#2 Zero-P" setting is inappropriate.
• When "#2055 pushf" is not set.
• When "Z71 Abs encoder failure 0005" has occurred.
In the above cases, if the "#2 Zero-P" setting is inappropriate, this means that the relation of "#2
Zero-P" and "#2037 G53ofs" is inappropriate. That is, if "#2 Zero-P" is smaller than the "#2037
G53ofs", the machine end stopper will be located between the basic machine coordinate system zero
point and reference position; this disables automatic initialization. (Refer to the following left figure.)
If "#2 Zero-P " is set to "0", the machine end stopper direction is unpredictable; this also disables
automatic initialization. (Refer to the following right figure.)
I - 489
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(3) Input "1" to "#0 Absolute posn set". The input value appears at "#0 Absolute posn set".
(4) Input an arbitrary value to "#2 Zero-P". The input value appears at "#2 Zero-P".
(5) Move the axis toward the mechanical State : [Origin Set]
basic position and align it to the marked Machine posn : [Not passed] -> current machine position
point.
-> a
(6) Input "1" to "#1 Origin-P". The input value appears at "#1 Origin-P".
(7) Move the axis in the direction designated State : [Ret. Ref. P.]
with the parameter "#2050 absdir".
-> b Machine end : Distance between machine basic point
(marked point) and the first grid point
I - 490
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
b Machine end
Basic machine c stopper
coordinate system Reference (Mechanical basic
zero point position position)
Grid point
Zero point parameter (electric basic
"#2037 G53ofs" position)
(Note 1) To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P",
and then turn the power OFF and ON.
(Note 2) If aligning axis on the marked point is attempted without passing the grip point once after turning the
power ON, the operation message "Not passed on grid" will appear. Return to a point before the last
grid, and then repeat from step of aligning the axis on the marked point.
(Note 3) If the first grid point is covered by the grid mask (#2028 grmask) as a result of return to the electric
basic position, the axis stops at the next grid point.
Note that zero-point shift amount (#2027 G28sft) is invalid.
(Note 4) Reconfirm the "absdir" setting if the machine does not move in the direction of "#2050 absdir". The
machine will move only in the positive direction when set to “0”, and the negative direction when set
to "1".
I - 491
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(3) Input "1" to "#0 Absolute posn set". The input value appears at "#0 Absolute posn set".
(4) Input an arbitrary value to "#2 Zero-P". The input value appears at "#2 Zero-P".
Input "1" to "#1 Origin-P". The input value appears at "#1 Origin-P".
State : [Complete]
Machine end : 0.000
Machine posn : The value set in "#2 ZERO"
Machine end
Basic machine stopper
coordinate system Reference (mechanical
zero point position basic position)
Reference position
parameter
"#2037 G53ofs"
(Note1) To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P",
and then turn the power OFF and ON.
(Note2) If aligning axis on the marked point is attempted without passing the grip point once after turning the
power ON, the operation message "Not passed on grid" will appear. Return to a point before the last
grid, and then repeat from step of aligning the axis on the marked point.
(Note3) If the first grid point is covered by the grid mask (#2028 grmask) as a result of return to the electric
basic position, the axis stops at the next grid point.
Note that zero-point shift amount (#2027 G28sft) is invalid.
I - 492
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(1) Select the axis that "#2049 type" is "3". Refer to "6.6.1 Selecting the Axis" for procedures to select
the axis.
(Note1) If the dog-type reference position return is interrupted by resetting, the previous state ("Complete"
or "Illegality") will display in the [State] column.
(Note2) With dog-type zero point return, reference position return can be executed again even if the [State]
is "Complete".
6.6.4 Precautions
(1) The "#0 Absolute posn set" parameter (axis for which zero point is to be initialized) can be set
simultaneously for all axes or individually for each axis.
(2) The "#0 Absolute posn set" parameter cannot be turned OFF with the keys. It is turned OFF when
the power is turned ON again.
(3) "#2 ZERO-P" can be set at any time as long as "#0 Absolute posn set" is set to "1".
(4) The grid point must be passed at least once after turning the power ON before initializing the zero
point. If the grid point has not been passed, the operation message "Not passed on grid" will appear
at the "Machine posn".
(5) When the absolute position is established, the required data will be stored in the memory.
I - 493
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(Example 1) To set the zero point at 50.0mm before absolute position origin point on + end
(Mechanical basic
position or electrical
basic position)
(Example 2) To set the zero point at 400.0mm before the machine basic position or absolute
position origin point on - end.
(Example 3) To set the basic machine coordinate system zero point on the grid point, calculate the
"#2 Zero-P" parameter setting value as shown below using the value displayed at
"Machine end". "Machine end" shows the distance from the mechanical basic position
to the previous grid point.
(Note that when setting the electrical basic position coordinate value in "#2 Zero-P",
the "Machine end" value does not need to be considered.)
To set the third gird point as the zero point when the "Machine end" display is -5.3 at the
+ end basic position. (Example of 10.0mm grid interval.)
10.0 10.0
I - 494
6. Maintenanace Screens
6.6 Absolute Position Detection Screen
(Example 1) To set the reference point to the same position as the basic machine coordinate
system zero point.
(Mechanical basic
position or electrical
basic position)
Basic machine "#2 Zero-P"
coordinate system
zero point
(Example 2) To set the reference point at a position 200.0mm to the + side from the basic machine
coordinate zero point.
(To set the basic machine coordinate system zero point 300.0mm front of the
absolute position origin point.)
"G53ofs" = 200.0
Absolute position
Reference point origin point
Basic machine
(Mechanical basic
coordinate system
position or electric
zero point
"#2 Zero-P" = 300.0 basic position)
I - 495
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
(1)
(2)
Display items
I - 496
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
I - 497
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
Menus
I - 498
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
6.7.1 Preparation
Before the screen is switched to auxiliary axis test screen, prepare the following things.
(3) Turn J2CT operation adjustment mode valid signal (R9998/bit0) ON.
I - 499
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
(1) Press the menu Axis select , input the If the axis No. that does not exist is designated, an
axis No. error will occur.
(2) Press the menu OpeTestmode . When the J2CT operation adjustment mode valid
signal from PLC is only turning ON while an auxiliary
axis is stopping, the menu OpeTestmode can be
turned ON.
(4) Set the "Parameter set" No. If the value other than 1 to 4 is set to "Parameter set",
a setting error will occur.
(5) Press the menu Normal Rot or The absolute position is set automatically.
Reverse Rot, start the axis.
I - 500
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
(1) Press the menu Axis select , input the If the axis No. that does not exist is designated, an
axis No. error will occur.
(2) Press the menu OpeTestmode . When the J2CT operation adjustment mode valid
signal from PLC is only turning ON while an auxiliary
axis is stopping, the menu OpeTestmode can be
turned ON.
(3) Press the menu Abs pos set . Status abs posn set : "Stopper"
(5) Set the "Parameter set" No. If the value other than 1 to 4 is set to "Parameter set",
a setting error will occur.
(6) When the operation mode is HANDLE, If the value other than 0 to 3 is set to "Scale", a setting
set the feed amount per pulse to "Scale". error will occur.
(7) The axis is traveled to machine end Status abs posn set : " Stopper" -> "Release"
stopper.
JOG : Press the menu Normal Rot
or Reverse Rot
HANDLE: Turn the handle.
-> a
When "#50101 Cont1/bitA" is "0" (absolute position basic point = mechanical basic position), the axis will
automatically stop without traveling. When absolute position coordinate zero point is set to mechanical basic
position or other than electrical basic position, the reference position is moved with "#50116 ABS Base
(absolute position zero point)".
Axis movement
a
#50116 ABS Base
Setting distance of absolute position zero point c b
Machine end stopper
When #50101 Cont1/bitA = 1 (Mechanical basic position)
Grid
Reference position (Electrical basic position)
I - 501
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
(1) Press the menu Axis select , input the If the axis No. that does not exist is designated, an
axis No. error will occur.
(2) Press the menu OpeTestmode . When the J2CT operation adjustment mode valid
signal from PLC is only turning ON while an auxiliary
axis is stopping, the menu OpeTestmode can be
turned ON.
(3) Press the menu Abs pos set . Status abs posn set : "Origin Set"
(5) Set the "Parameter set" No. If the value other than 1 to 4 is set to "Parameter set",
a setting error will occur.
(6) When the operation mode is STEP or If the value other than 0 to 3 is set to "Scale", a setting
HANDLE, set the feed amount per pulse to error will occur.
"Scale".
(7) Press the menu Origin pos set , Status abs posn set : "Ret. Ref. P."
designate the basic point.
When "#50101 Cont1/bitA" is "0" (absolute position basic point = mechanical basic position), the axis will
automatically stop without traveling. When absolute position coordinate zero point is set to mechanical basic
position or other than electrical basic position, the reference position is moved with "#50116 ABS Base
(absolute position zero point)".
Axis movement a
#50101 Cont1/bitA = 0
I - 502
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
Depending on the state during operation, the display will change as shown below. Refer to the following table
for details on each display item.
With operation
Without operation
Display item of
Details
"Status abs posn set"
Illegality This appears when the absolute position has been lost.
Stopper This appears after the absolute position initialization set is started and the
machine end is pushed against.
Release This appears after the machine end is pushed against, and the current limit is
reached continuously for a set time.
Origin Set This appears after the absolute position initialization set is started, and the
origin point is designated moving to the mechanical basic position.
Ret. Ref. P. This appears after the basic point is designated, and the nearest grid is
reached with the "#50120 ABS TYPE" basic point direction movement.
Zero-P. Rel. This appears when the reference position has been returned to with the
dog-type initialization.
Complete This appears when the absolute position initialization set has been
completed.
This displays the state that the absolute position has been established.
(Note) When using position setting methods other than the dog-type method, mechanical end stopper method,
marked point alignment method, the initialization state will be blank.
I - 503
6. Maintenanace Screens
6.7 Auxiliary Axis Test Screen [700 series only]
Operation methods
The test operation can be carried out with menu Normal Rot/Reverse Rot by separating the auxiliary axis
control from the PLC.
(1) Press the menu Axis select , input the If the axis No. that does not exist is designated, an
axis No. error will occur.
(2) Press the menu OpeTestmode . When the J2CT operation adjustment mode valid
signal from PLC is only turning ON while an auxiliary
axis is stopping, the menu OpeTestmode can be
turned ON.
(3) Select the "Operation mode". If the value other than 1 to 5 is set to "Operation
mode", a setting error will occur.
(4) When the operation mode is STEP or If the value other than 0 to 3 is set to "Scale", a setting
HANDLE, set the feed amount per pulse to error will occur.
"Scale".
(5) Set the "Parameter set" No. If the value other than 1 to 4 is set to "Parameter set",
a setting error will occur.
6.7.4 Precaution
(1) Do not turn "Auto operation "start" command signal (ST) " ON during Ope. test mode.
(2) If the screen shifts other screen, the auxiliary axis mode (Ope. test mode, Absolute posn set) is held.
However, the axis stops if the axis is rotating.
I - 504
6. Maintenance Screen
6.8 Diagnosis Data Collection Setting Screen
(1)
(2)
(3)
Display items
I - 505
6. Maintenance Screen
6.8 Diagnosis Data Collection Setting Screen
Menus
Start This begins collecting sampling data and history data. A 6.8.1 Performing a
Data Collection
Operation
Stop This stops the sampling data and history data collection A 6.8.2 Stopping a
operation. Data Collection
Operation
Data This stops the sampling data and history data collection A 6.8.3 Clearing a
clear operation, and clears the collected data. Collected Data
I - 506
6. Maintenance Screen
6.8 Diagnosis Data Collection Setting Screen
Operation methods
(1) Press the menu Start . An operation message "The collection begin?"
appears.
(2) Press Y or INPUT key. Data collection begins, and "History collecting"
and "Sampling" appears in the status column.
Operation methods
(1) Press the menu Stop . An operation message "The collection stop?"
appears.
(2) Press Y or INPUT key. Data collection stops, and "History stop" and
"Sampling stop" appears in the status column.
To resume data collection, press the menu
Start .
Operation methods
(1) Press the menu Data clear . An operation message "Execute the collection
data clear?" appears.
I - 507
II. MACHINE OPERATIONS
This chapter explains the functions and operation method of the machine operation switches for operation
(automatic operation and manual operation) by using the illustration of the machine operation panel.
The actual machine operation and motion vary by machine specification. Refer to the operation manual issued
by the machine tool builder. Use this chapter for reference.
MISCELLA-
SINGLE NEOUS
DRY RUN BLOCK FUNCTION CANCEL
CONTROL IN AUTO ALARM M00 M02 M30 LOCK Z LOCK
UNIT OPERATION ON ON ON ON ON ON
READY
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
REFERENCE POINT
HANDLE/INCREMENTAL HANDLE FEED RAPID TRAVERSE FEED RATE
MAGNIFICATION AXIS SELECTION OVERRIDE OVERRIDE MANUAL FEED RATE RESET
150 100 X Y Z 4
1000 1 140 160 72.0 140. 0
Y Z 100 130 170 52.0
100 1000 5000 10 50 120 180 31.0
200. 0
270. 0
100 10000 X 4 110 190 21.0 370. 0
100
100 25 90
200 20.0 520. 0
FEED AXIS SELECT
10 80
210
220
14.0
10.0
720.0
1000.0
10 50000 70 230 7.2 1400.0
1 1 60 240 6.2 2000.0 +X +Y +Z +4
1000 50 250 3.7 2700.0
1 100000 40
30
260 2.7 3700.0
270 2.0 5200.0
20 280 1.4 7200.0
10 290 1.0 10000.0
0 300 0 14000.0
% % mm/min
-X -Y -Z -4
HANDLE
SPINDLE OVERRIDE
- 00 + MODE SELECT
10 72 MEMORY
10 10 80 90
MDI RAPID TRAVERSE
70 100
TAPE JOG
60 110 EMERGENCY STOP
HANDLE REFERENCE POINT
50 120 RETURN CYCLE START FEED HOLD
INCREMENTAL
II - 1
1. Operation State
1.1 Operation State Correlation Diagram
1. Operation State
1.1 Operation State Correlation Diagram
The controller operation state changes momentarily according to the program contents or signals from the
operation panel or machine. The operation states are roughly classified into power OFF, not ready, and
ready.
Manual mode operation is enabled in the operation complete state.
(a)
Power OFF state
Power OFF
(b) Power ON
Automatic
Feed hold (g) (f) operation
is started
CRT operations
Start Input (Machinery preparation)
(f) Automatic
Automatic operation in operation Searching unmodal
progress not ready
state Completed
M02/30
Automatic
Block stop (h) (f) operation
is started
Automatic operation is
stopped
II - 2
1. Operation State
1.3 Operations Not Ready
1.4.1 Reset
The reset state means that the controller is reset.
(1) From not ready to reset (Transition of operation state correlation diagram (d))
This state is also called initial state.
• When about four seconds has passed after the power is turned ON.
(2) From another ready state to reset (Transition of operation state correlation diagram (e))
• When the RESET key on the setting and display unit is turned ON;
• When external reset signal is input from the machine; or
• When M02 or M30 is executed (depending on the machine specifications).
! CAUTION
Stay out of the moveable range of the machine during automatic operation. Keep hands, feet and
face away from the rotating spindle.
II - 3
2. Indicator Lamps
2.1 Control Unit Ready
2. Indicator Lamps
2.1 Control Unit Ready
The CONTROL UNIT READY lamp indicates that the control unit is ready to run. The lamp goes OFF at
emergency stop or when an alarm occurs in the drive or operation block.
2.6 Alarm
The ALARM lamp goes ON when an alarm occurs during NC running.
2.7 M00
If M00 given in a program is executed during automatic operation, automatic operation stop is performed after
execution of the M00 block is completed. The M00 lamp is turned ON. (This depends on PLC processing.)
2.8 M02/M30
When M02 or M30 is executed during automatic operation, the NC unit reaches the program end and the
M02 or M30 lamp is turned ON. (This depends on PLC processing.)
II - 4
3. Reset Switch and Emergency Stop Button
3.1 Reset Switch
! CAUTION
! If the axis overruns or emits an abnormal noise, immediately press the emergency stop button and
stop the axis.
II - 5
4. Operation Mode
4.1 Mode Selection Switch
4. Operation Mode
4.1 Mode Selection Switch
The MODE SELECT switch is used to determine the controller operation mode.
(Note 1) Refer to the section 1.4 for the running state when a mode is changed to another one during
automatic operation.
Operation procedure
Using the MODE SELECT switch, select the jog mode.
To move the controlled axis, turn on the FEED AXIS SELECT switch. The
controlled axis is moved while the switch is turned on.
When the switch is turned off, the controlled axis stops with deceleration.
(Note 1) When the MANUAL OVERRIDE switch on the operation panel is turned ON, the override value set
by using the FEED RATE OVERRIDE switch takes precedence over the feedrate set by using the
MANUAL FEED RATE switch.
II - 6
4. Operation Mode
4.3 Rapid Traverse Feed Mode
(Note 1) Refer to the manual issued by the machine tool builder for the rapid traverse feedrate.
(Note 2) Refer to the section 5 for the RAPID TRAVERSE OVERRIDE switch.
Operation procedure
Using the MODE SELECT switch, select the rapid traverse feed mode.
Using the RAPID TRAVERSE OVERRIDE switch, set arbitrary override value.
To move the controlled axis, turn ON the FEED AXIS SELECT switch. The
controlled axis is moved while the switch is turned ON.
When the switch is turned OFF, the controlled axis stops with deceleration.
(Note 1) The override value set by using the CUTTING FEED OVERRIDE switch is not effective for the rapid
traverse feedrate; when the override value is 0%, the controlled axis does not move.
II - 7
4. Operation Mode
4.4 Reference Point Return Mode
(–) (+)
Dog
Reference point
(–) (+)
Dog
Reference point
The steps below describe what happens to the controlled axis when it returns to the reference point for
the first time with the power ON and with the machine in an "operations not ready state" (emergency stop
is engaged or the servo alarm is ON) or when the parameters are selected in the dog mode.
(1) The controlled axis is moved in the direction where the near point detection limit switch and dog
approach each other in the reference point return mode.
(2) When the limit switch kicks the dog, the controlled axis once stops with deceleration.
(3) Next, the controlled axis moves to the reference point at the approach rate set in the parameter.
(4) When it arrives at the reference point, the reference point arrival signal is output.
(5) The reference position establishment signal is output.
If high-speed return is set in a given parameter after dog mode reference point return is executed, then
high-speed reference point return will be made.
II - 8
4. Operation Mode
4.4 Reference Point Return Mode
If the return direction is erroneous in high-speed reference point return, an alarm occurs.
A return is made to the reference point at the rapid traverse feedrate.
Minus Plus
Dog
Reference point
Operation procedure
Using the MODE SELECT switch, select the reference point return mode.
Using the RAPID TRAVERSE OVERRIDE switch, set arbitrary override value.
Machine table
Plus movement Minus movement
Dog
Reference point
Limit switch
The machine position depends on whether the near point detection limit switch is on the plus or minus
side with the near point dog on the machine table as illustrated above as the reference.
When the limit switch exists on the dog, move to either plus or minus.
For dog mode reference point return, turn ON the FEED AXIS SELECT switch (+ or -) in the direction
where the dog and limit switch approach each other.
For high-speed reference point return, turn ON the FEED AXIS SELECT switch (+ or -) in the direction
that the spindle head approaches the reference point.
Hold the FEED AXIS SELECT switch ON during reference point return until the machine passes by the
dog (dog mode) or the REFERENCE POSITION ARRIVAL lamp goes ON (high speed return).
II - 9
4. Operation Mode
4.5 Incremental Feed Mode
Operation procedure
Using the MODE SELECT switch, select the incremental feed mode.
The controlled axis selected by turning ON the FEED AXIS SELECT switch once is
moved at a given distance.
Operation procedure
Using the MODE SELECT switch, select the handle feed mode.
Using the HANDLE FEED AXIS SELECT switch, select the controlled axis to be
moved.
in arbitrary direction. -
00 +
10 72
10 10
II - 10
4. Operation Mode
4.7 Memory Mode
Operation procedure
Call the work program for memory operation by using the setting and display unit.
The CYCLE START switch becomes effective when it is once turned ON, then OFF.
To temporarily stop machine motion, turn ON the FEED HOLD switch. The
controlled axes being moved stop with deceleration.
When machine motion is stopped by using the FEED HOLD switch, automatic operation will be restarted
by turning ON the CYCLE START switch.
Memory operation terminates when M02 or M30 in the program is executed. The M02 or M30 lamp on
the machine operation panel is turned ON.
To repeat executing the same program, input the rewind signal by reset & rewind with user PLC.
To forcibly terminate automatic operation, turn ON the RESET switch.
! CAUTION
! Carry out dry run operation before actually machining, and confirm the machining program, tool
offset amount and workpiece coordinate system offset amount.
II - 11
4. Operation Mode
4.8 MDI Operation Mode
Operation procedure
The MDI operation follows the memory operation.
Set data on the setting and display unit MDI program editing screen.
The following steps are the same as the memory operation steps. Refer to 4.7.
(Note 1) When using a 2-part system, the MDI data operation can be switched with the parameters.
#1050 MemPrg Details
The common MDI program for the part system is run in each part
0, 2, 4, 6
system.
1, 3, 5, 7 MDI programs for each part system are run in each part system.
II - 12
5. Operation Panel Switches in Operation Mode
5.1 Rapid Traverse Override
manual operation.
100
RAPID TRAVERSE OVERRIDE is applicable to the 50
following: 25
(Note 1) The dry run rate is the movement rate set by using the MANUAL FEED RATE switch by overriding
the programmed feedrate in automatic operation.
(Note 2) Refer to the section 6.5 for feedrate override applied to manual feedrate.
100
II - 13
5. Operation Panel Switches in Operation Mode
5.4 Handle/Incremental Feed Magnification
1 1 1000 1
100 1000 5000 10
100 10000
10 10 10 100
10 50000
100 100 1
1
1000
100000
1000 1000
5000 5000
10000 10000
50000 50000
100000 100000
II - 14
5. Operation Panel Switches in Operation Mode
5.7 Cycle Start and Feed Hold
The CYCLE START switch becomes effective when the switch is turned ON, then OFF.
Use the FEED HOLD switch to temporarily stop automatic operation (for example, deceleration stop of
the control axis during automatic operation). To restart operation, use the CYCLE START switch.
Use the FEED AXIS SELECT switch to start FEED AXIS SELECT
the controlled axis during manual operation. +X +Y +Z +4
While the FEED AXIS SELECT switch is held
ON, the selected controlled axis is moved.
When the switch is turned OFF, the controlled -X -Y -Z -4
axis movement stops.
II - 15
6. Operation Panel Switch Functions
6.1 Chamfering
II - 16
6. Operation Panel Switch Functions
6.6 Override Cancel
Program N1G54 ;
N2G90G81X50. Z-20. R3. F100 ;
/N3X30. ;
N4X10. ;
N5G80 ;
M02 ;
N4 N2 N4 N3 N2
II - 17
6. Operation Panel Switch Functions
6.9 Manual Absolute
X
W
Feed hold stop Path on program
(absolute command)
Manual interrupt
(Program coordinate system is not updated by
tool move distance.)
Path after manual interrupt
-Y
When MANUAL ABSOLUTE Switch Is ON
X
W
Path on program
Feed hold stop (absolute command)
Manual interrupt
(Program coordinate system is updated by tool
move distance.)
Path after manual interrrupt
II - 18
6. Operation Panel Switch Functions
6.10 Error Detect
X axis command
Y axis command
Error detect off
Y axis command
Error detect on
II - 19
6. Operation Panel Switch Functions
6.14 Handle Interruption
Y Tool
X Z Interrupt
10
1 100
Workpiece
Handle feed
Automatic feed
G01 Z __ F
X __ Y __ ;
X __ Y __ ;
X __ Y __ ;
II - 20
6. Operation Panel Switch Functions
6.14 Handle Interruption
Program path
(G91 X_ Y_;)
II - 21
6. Operation Panel Switch Functions
6.14 Handle Interruption
Program path
(G90 X_ Y_;)
Program path
(G90 X_ Y_;)
II - 22
6. Operation Panel Switch Functions
6.14 Handle Interruption
Program path
(G90 X_ Y_;)
Distance of interruption by
manual handle
Program path
(G90 X_ Y_;)
B
A
II - 23
6. Operation Panel Switch Functions
6.14 Handle Interruption
Program path
G42
Tool path
Distance of interruption by
manual handle
Path after interruption
(Incremental mode, continuous operation)
Program path
G42 G40
R
R
Tool Tool path
R
radius
Distance of interruption by
manual handle
Program path
G42 G40
R R
Tool
radius Tool R
path
Distance of interruption
by manual handle
Path after interruption
II - 24
6. Operation Panel Switch Functions
6.14 Handle Interruption
Program path
G42 G40
Tool path
Distance of interruption
by manual handle
Path after interruption
(Absolute mode, program absolute position update valid, continuous operation)
Select interrupt axis by setting the HANDLE AXIS SELECTION switch on the
machine operation panel.
Select the travel distance per handle graduation by setting the HANDLE/
INCREMENTAL MAGNIFICATION switch.
Program path
Tool path (current position
(handle interrupt display) display)
Handle interrupt
II - 25
6. Operation Panel Switch Functions
6.15 Machine Lock
II - 26
6. Operation Panel Switch Functions
6.16 Deceleration Check
II - 27
6. Operation Panel Switch Functions
6.16 Deceleration Check
Ts
Ts : Acceleration/deceleration time constant
Td Td : Deceleration check time
Td = 2 × Ts + (0 to 14ms)
2 × Ts
Td Ts
Ts : Acceleration/deceleration time constant
Td : Deceleration check time
Td = 2 × Ts + (0 to 14ms)
The deceleration check time required during rapid traverse is the longest rapid traverse deceleration
check time of all axes. This check time is determined by the rapid traverse acceleration/deceleration
mode and rapid traverse acceleration/deceleration time constant of simultaneously commanded
axes.
The deceleration check time required during cutting feed is determined in the same manner. It is the
longest cutting feed deceleration check time of all axes. This check time is determined by the cutting
feed acceleration/deceleration mode and cutting feed acceleration/deceleration time constant of
simultaneously commanded axes.
II - 28
6. Operation Panel Switch Functions
6.16 Deceleration Check
Speed
G0inps (G1inps)
SV024
Command to motor
Motor speed
If the SV024 setting value is larger, in-position check will end when the SV024 setting value is
established.
II - 29
6. Operation Panel Switch Functions
6.16 Deceleration Check
G0Ipfg:0
G1 G0
G1 G0
G0Ipfg:1 G1 G0
G1 G0 Commanded
deceleration
G0Ipfg:0
G1 G1
G1 G1
G0Ipfg:1 G1 G1
G1 G1 Commanded
deceleration
II - 30
6. Operation Panel Switch Functions
6.16 Deceleration Check
6.16.4 Parameters
(1) Designation of deceleration check
Base specification parameters
# Items Details Setting range
1193 inpos Change with the "#1306 InpsType" (deceleration check designation type).
0: Deceleration check method1
1: Validate in-position check
II - 31
6. Operation Panel Switch Functions
6.16 Deceleration Check
6.16.5 Precautions
(1) Designating deceleration check
• When in-position check is valid, set the in-position width in the servo parameters.
II - 32
6. Operation Panel Switch Functions
6.16 Deceleration Check
(Note 1) When G1 command is issued, the in-position check is performed regardless of the deceleration
check parameter.
(Note 2) XX expresses all commands.
(6) Deceleration check in polar coordinate interpolation / milling interpolation / cylindrical start /
cancel command
• The deceleration check in polar coordinate interpolation / milling interpolation / cylindrical start / cancel
command are as follows.
II - 33
7. Stored Stroke Limit
Outline
Three tool entry prohibited ranges can be set with stored stroke limit I, stored stroke limit II, IIB and stored
stroke limit IB. Part of the prohibited range on the outside of soft limit I can be validated with stored stroke limit
IC.
The stored stroke limit II and IIB select the outer side (II) and inner side (IIB) of the entry prohibited range with
parameters.
Stored stroke
limit IC
If the tool tries to move over the set range, an alarm will appear, and the axis will decelerate to a stop.
If the prohibited range is entered and an alarm occurs, movement will be possible only in the direction
opposite the entry direction.
! CAUTION
Always set the stored stroke limit. Failure to set this could result in collision with the machine end.
(Note) The axis movement possible when the reference point return has not yet completed is limited to
manual and handle feed only. Automatic operation is validated after the reference point return is
completed.
II - 34
7. Stored Stroke Limit
Detailed explanation
The stored stroke limit sets a prohibited range with the parameters or program command. The maximum and
minimum values of the prohibited range are set as coordinate values (radius values) on the basic machine
coordinate system for each axis. If the parameters (#8204 OT-CHECK-N and #8205 OT-CHECK-P), for
setting the prohibited range, are set to the same value, the stroke will not be checked. This function is valid
only for the axis for which the reference point is established.
If the machine enters the prohibited range, an operation error will occur, and the machine movement will stop.
The alarm can be reset by moving the erroneous axis in the opposite direction.
During automatic operation, if an alarm occurs with even one axis, all axes will decelerate to a stop. During
manual operation, only the axis that caused the alarm will decelerate to a stop. The axis will always stop at a
position before the prohibited range. The distance between the prohibited range and stop position will depend
on the feedrate.
The stored stroke limits I, II, IIB, IB and IC are handled as follows.
II - 35
7. Stored Stroke Limit
7.1 Stored Stroke Limit I
This is a stroke limit function used by the machine maker. The boundary is set with the parameters (axis
specification parameters "#2013 OT-" and "#2014 OT+"). The outside of the set boundary is the prohibited
range.
When used with the stored stroke limit II function, the narrow range designated by the two types becomes the
movement valid range.
Point 1
Prohibited range
the basic machine coordinate
Machine movement valid range system.
Point 1: #2014 OT+
Point 2: #2013 OT-
Point 2
II - 36
7. Stored Stroke Limit
7.2 Stored Stroke Limit II
The boundary is set with the parameters (axis parameters #8204 OT-CHECK-N, #8205 OT-CHECK-P) or
with the program commands. Either the inside or the outside of the set boundary is the prohibited range.
Whether the inside or outside of the range is prohibited is determined by parameter (#8210 OT-INSIDE).
When the inside is selected, this function is called stored stroke limit IIB.
When using program commands, entry of the tool into the prohibited range is prohibited with G22, and entry
into the prohibited range is enabled with G23.
The stored stroke limit II function can be invalidated for each axis with the parameter setting (#8202
OT-CHECK OFF: 1).
"#8210 OT-INSIDE" can be set for each axis, but when used in combination, the following type of operation is
possible.
Outside
Moveable range
Moveable range
Outside
Inside
Moveable range
Inside
Inside
Moveable range
II - 37
7. Stored Stroke Limit
7.2 Stored Stroke Limit II
When used with the stored stroke limit I function, the narrow range designated by the two types becomes the
movement valid range.
Point 1
Prohibited range
prohibited with Point 3 and 4:
stored stroke #8205 OT-CHECK-P
limit II Machine movement
valid range #8204 OT-CHECK-N
A range except for that of the stored stroke limit I becomes the movement prohibited range.
Point 1
Point 3
Basic machine
Range prohibited coordinate system
Prohibited range
Prohibited range
Point 4
+ setting value
II - 38
7. Stored Stroke Limit
7.3 Stored Stroke Limit IB
The boundary is set for each axis with the parameters (axis parameters "#2061 OT_1B-" and "#2062
OT_1B+"). The inside of the set boundary is the prohibited range.
Prohibited range
with stored stroke coordinate Point 4 : #2061 OT_1B-
limit IIB Machine system
movement Points 1 and 2 are the
valid range prohibited range set with
Point 4 stored stroke limit I, and points
3 and 4 are the prohibited
Point 2 - setting value range set with stored stroke
limit II.
+ setting value
The boundary is set for each axis with the parameters (axis parameters "#2061 OT_1B-" and "#2062
OT_1B+"). The inside of the set boundary is the machine movement valid range.
This is valid when the axis parameter #2063 is set to 2, and cannot be used with soft limit IB.
Point 1
coordinate system.
Point 3 : #2062 OT_1B+
Machine movement valid range Point 4 : #2061 OT_1B-
Point 3
Points 1 and 2 are the
prohibited range set with
Point 2 Additional stored stroke limit I.
movement
range
Point 4
II - 39
7. Stored Stroke Limit
7.5 Movable Range during Inclined Axis Control
By setting #2063 OT_1Btype to "3", the inclined axis control axis can be checked with the program
coordinates using the stored stroke limit IB/IC range setting (#2061, #2062). The stored stroke limit IB and IC
cannot be used together at this time.
By using this function with stored stroke limit I, the check can be carried out simultaneously with the actual
axis and program coordinate value. In this case, the range that does not fit into either of the following two
prohibited ranges will be the movable range.
X axis
i i
Point 3
The following values are set
with the coordinate values in
the basic machine coordinate
Point 1 system.
y axis Point 3: #2062 OT_1B+
θ Point 4: #2061 OT_1B-
Point 2
Points 1 and 2 are the
Movable range prohibited range set with
Y axis stored stroke limit I.
Point 4
Movement prohibited range
II - 40
7. Stored Stroke Limit
7.6 Stored Stroke Limit for Rotation Axis
Stored stroke limits I and II are used as the stored stroke limit for the rotation axis. The area between the
maximum and minimum values of the prohibited range's parameters, which does not contain the 0 point of
the basic machine coordinate system, is the entry prohibited range.
The prohibited range parameters for the rotation axis can be set to establish "maximum value < minimum
value". This will be handled in the same manner as if "maximum value > minimum value".
(Example)
Stored stroke limit I (maximum value and minimum value of prohibited range parameter)
#2013 OT- : -70.000°
#2014 OT+ : 60.000°
Stored stroke limit II (maximum value and minimum value of prohibited range parameter)
#8204 Soft limit - : 30.000°
#8205 Soft limit + : 80.000°
0°
Movable range
-70° (290°)
(Note) Do not use stored stroke limits IB, IIB or IC. Invalidate stored stroke limits IB, IIB and IC by setting the
parameters as shown below.
#8210 OT INSIDE: 0 (stored stroke limit II valid, IIB invalid)
#2061, #2062 set to same value (stored stroke limits IB and IC invalid)
II - 41
7. Stored Stroke Limit
7.7 Precautions
7.7 Precautions
(1) If the maximum value and minimum value of the stored stroke limit's prohibited range are set to the same
value, the following will occur.
• When the maximum value and minimum value are set to 0, if the outside is the prohibited range, the
entire range will be prohibited. If the inside is the prohibited range, the entire range will be the
moveable range.
• If data other than 0 is set for the maximum value and minimum value, the entire range will be the
moveable range.
(2) The stored stroke limit IC is valid when the axis parameter #2063 is changed.
If changed during automatic operation, the function will be validated after the smoothing for all axes
reaches 0.
(3) Make sure that the lower limit value of the stored stroke limit IC setting value is "smaller than the upper
limit value".
II - 42
III. MAINTENANCE
1. Daily Maintenance and Periodic Inspection and Maintenance
1.1 Maintenance Items
1.1.1 Escutcheon
(1) Cleaning the escutcheon
(a) Prepare the rear side of the escutcheon to clean.
(b) Wipe the escutcheon with a soft, clean, dry cloth. If cleaning is still required, put some neutral
detergent on a cloth and wipe. Do not use alcohol, thinner, etc.
III - 1
1. Daily Maintenance and Periodic Inspection and Maintenance
1.1 Maintenance Items
III - 2
1. Daily Maintenance and Periodic Inspection and Maintenance
1.2 Replacement Methods [700 series]
All data, such as the parameters and machining programs that need to be backed up when the power is
turned OFF, are saved by a lithium battery installed in the control unit's battery holder.
(Note) Replace the battery when the alarm "Z52 Battery drop 0001" appears on the NC screen. The internal
data could be damaged if the alarm "Z52 Battery drop 0003" appears.
[Replacement procedures]
Always replace the battery with the control unit (machine) power turned OFF.
Complete the replacement within 30 minutes after turning the power OFF. (If the battery is not connected
within 30 minutes, the data being backed up may be destroyed.)
(1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.)
(2) Open the electric cabinet door, and confirm that the control unit LED, 7-segment display, etc., are all
OFF.
(3) Open the front cover of the control unit by pulling on the right side of the door.
(4) Pull the connector connected to the battery out from the BAT connector.
(5) Remove the battery from the battery holder.
(6) Fit the new battery into the battery holder.
(7) Insert the connector connected to the new battery into the BAT connector. Pay attention to the
connector orientation, being careful not to insert backwards.
(8) Close the front cover of the control unit. At this time, confirm that the cover is closed by listening for
the "click" sound when the latch catches.
(9) Close the door of the electric cabinet.
Front cover
BAT connector
Battery holder
Connector connected
to the battery
Battery
III - 3
1. Daily Maintenance and Periodic Inspection and Maintenance
1.2 Replacement Methods [700 series]
! CAUTION
If the battery low warning is issued, save the machining programs, tool data and parameters in an
input/output device, and then replace the battery. When the battery alarm is issued, the machining
programs, tool data and parameters may be destroyed. Reload the data after replacing the battery.
! Do not short circuit, charge, overheat, incinerate or disassemble the battery.
! Dispose the spent battery according to the local laws.
III - 4
1. Daily Maintenance and Periodic Inspection and Maintenance
1.2 Replacement Methods [700 series]
Type ........109P0412H731
Life ..........60,000 hours (When the rotary speed decreased 30% less than the initial values)
Life is a presumption value in 60°C environment, not guaranteed value.
[Replacement procedures]
Always replace the cooling fan with the control unit (machine) power turned OFF.
(1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.)
(2) Open the electric cabinet door.
(3) Remove the fan cover on the top center of the control unit. (Remove the fan cover by pushing up the
front tab.)
(4) Pull out the cooling fan from the control unit cooling fan housing.
(5) Pull the connector connected to the cooling fan out from the control unit PCB.
(6) Replace the cooling fan with the new one. Insert the connector connected to the new cooling fan into
the control unit PCB.
(7) Put the cooling fan into the control section cooling fan housing. (Be sure the label side is on the top.)
(8) Arrange the cooling fan wiring neatly in the control unit cooling fan housing.
(9) Install the fan cover. (First install the back tabs in the control unit. Then install the front tabs in the
control unit.)
(10) Check the cables and wires for leaks of connection, faulty connections, etc., then close the electric
cabinet door.
Front tab
Back
tab Control unit
! Caution
! Do not replace the control unit while the power is ON.
! Collect and dispose of the spent cooling fan according to the local laws.
III - 5
1. Daily Maintenance and Periodic Inspection and Maintenance
1.2 Replacement Methods [700 series]
Type ........MMF-06D24DS-RP3
Life ..........50,000 hours (When the rotary speed decreased 20% less than the initial values)
Life is a presumption value in 60°C environment, not guarantee value.
[Replacement procedures]
Always replace the cooling fan for display unit with the control unit (machine) power turned OFF.
(1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.)
(2) Open the electric cabinet door.
(3) Remove the fan cover of cooling fan housing (2 parts) that is installed to PCB on back of display unit.
(Remove the fan cover by pushing up the front tab.)
(4) Pull out the cooling fan from the control unit cooling fan housing.
(5) Pull the connector connected to the cooling fan out from the control unit PCB.
(6) Replace the cooling fan with the new one. Insert the connector connected to the new cooling fan into
the control unit PCB.
(7) Put the cooling fan into the control section cooling fan housing. (Be sure the label side is on the top.)
(8) Arrange the cooling fan wiring neatly in the control unit cooling fan housing.
(9) Install the fan cover.
(10) Check the cables and wires for leaks of connection, faulty connections, etc., then close the electric
cabinet door.
Tab
Fan cover
Cooling fan
Cooling fan
housing
! Caution
! Do not replace the control unit while the power is ON.
! Collect and dispose of the spent cooling fan according to the local laws.
III - 6
1. Daily Maintenance and Periodic Inspection and Maintenance
1.2 Replacement Methods [700 series]
[Replacement procedures]
Always replace the compact flash with the control unit (machine) power turned OFF.
(1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.)
(2) Open the electric cabinet door, and confirm that the control unit LED, 7-segment display, etc., are all
OFF.
(3) Open the front cover of the control unit.
(4) Press the eject lever twice to eject the compact flash.
(5) Insert the new compact flash. (The surface is faced on the observers' right.)
(6) Close the front cover of the control unit. At this time, confirm that the cover is closed by listening for
the "click" sound when the latch catches.
(7) Close the door of the electric cabinet.
Front
cover
Eject lever
Compact flash
(Note 1) There may be a compatibility problem between devices a commercially available compact flash
memory, so illegal operations may occur.
III - 7
1. Daily Maintenance and Periodic Inspection and Maintenance
1.2 Replacement Methods [700 series]
1.2.3 IC Card
Front IC card
(1) Open the card slot door on display unit right end.
(2) Insert the IC card. (The surface is faced on the observers' right.)
(1) Open the card slot door on display unit right end.
(2) Press the eject lever twice to eject the IC card.
Eject lever
IC card
III - 8
1. Daily Maintenance and Periodic Inspection and Maintenance
1.3 Replacement Methods [70 series]
All data, such as the parameters and machining programs that need to be backed up when the power is
turned OFF, are saved by a lithium battery installed in the control unit's battery holder.
[Replacement procedures]
Always replace the battery with the control unit (machine) power turned OFF.
Complete the replacement within 30 minutes after turning the power OFF. (If the battery is not connected
within 30 minutes, the data being backed up might be destroyed.)
(1) Check that the machine power is turned OFF. (If the power is not OFF, turn it OFF.)
(2) Confirm that the control unit LED, 7-segment display, etc., are all OFF.
(3) Open the battery cover of the control unit. Pull the right side of the battery cover toward front.
(4) Pull the connector connected to the battery out from the BAT connector.
(5) Remove the battery from the battery holder.
(6) Fit the new battery into the battery holder.
(7) Insert the connector connected to the new battery into the BAT connector. Pay attention to the
connector orientation, being careful not to insert backwards.
(8) Close the front cover of the control unit. At this time, confirm that the cover is closed by listening for
the "click" sound when the latch catches.
Battery cover
Battery
Battery holder
BAT connector
III - 9
1. Daily Maintenance and Periodic Inspection and Maintenance
1.3 Replacement Methods [70 series]
! CAUTION
If the battery low warning is issued, save the machining programs, tool data and parameters in an
input/output device, and then replace the battery. When the battery alarm is issued, the machining
programs, tool data and parameters may be destroyed. Reload the data after replacing the battery.
Do not short circuit, charge, overheat, incinerate or disassemble the battery.
Dispose the spent battery according to the local laws.
III - 10
1. Daily Maintenance and Periodic Inspection and Maintenance
1.3 Replacement Methods [70 series]
Compact flash
Eject lever
III - 11
IV. APPENDIXES
Appendix 1. List of Function Codes
(Note 1) Codes not listed in the above table are stored on tape, but an error will result during operation if they
are not comments.
(Note 2) This denotes characters (including blanks) which are stored inside and which correspond to the
command codes. "@" is not displayed.
IV - 1
Appendix 2. Table of Command Value Ranges
IV - 2
Appendix 2. Table of Command Value Ranges
IV - 3
Appendix 2. Table of Command Value Ranges
IV - 4
Appendix 2. Table of Command Value Ranges
IV - 5
Appendix 2. Table of Command Value Ranges
IV - 6
Appendix 2. Table of Command Value Ranges
IV - 7
Appendix 3. Circular Cutting Radius Error
F
A
F A : Command coordinate
B : Tracking coordinate
B
R : Command radius (mm)
ΔR : Radius error (mm)
Δθ : Angle error (rad)
Δθ
F : Cutting feed rate (m/min)
ΔR
The radius error ΔR and angle error Δθ are calculated from the following formula.
Exponential 1 1 2
1 2
F × 103 2
acceleration/ deceleration ΔR = R • ( 2 Ts + 2 Tp ) • ( 60 ) (mm)
Linear 1 1 1 F × 103 2
acceleration/ deceleration ΔR = R • ( 24 Ts2 + 2 Tp2) • ( 60 ) (mm)
F F
Δθ= tan-1 (Ts • -1
R ) + tan (Tp • R ) (rad)
Ts: Time constant (s) of specified smoothing circuit
Tp: Position loop time constant
(Note 1) When the ΔR radius error applying with circular cutting does not come within the allowable value,
proceed to reduce the cutting feed rate F, set Ts to a lower value or review the program.
(Note 2) In the steady state, ΔR is constant. However, it is not constant with command start and stop
transitions. Under command start and stop conditions, therefore, the tracking coordinate should be
as shown in the figure below.
Start/stop
ΔR
ΔR
Command Tracking
IV - 8
Appendix 4. Registering/Editing the Fixed Cycle Program
4.1 Fixed Cycle Operation Parameters
! CAUTION
Do not change the fixed cycle program without prior approval from the machine maker.
IV - 9
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
G31 Z #5 F #3 ;
1F [ROUND [ ABS [#2 - [ ##10 ∗ #11 − #12 ] ] ] GT #8 ] GOTO 1 ;
1F [ROUND [ ##10 ∗ #11 - #12 ] EQ #4 ] GOTO 1 ;
##9 = #10 - #12/#11 - #2/#11 + ##9 ;
#3003 = #1 ;
N2 ;
M99 ;
N1 # 3901 = 126 ;
G. 1 ;
1F [ ABS [ #2 ] GT 0 ] GOTO 10 ;
#14 = 1 ;
N10 #13 = #3 ;
IF [ #15 NE 0 ] GOTO 11 ;
#13 = #3 - #5 ;
N11 #16 = 0 ;
D0 1 ;
#10 = 0 ;
#11 = #4 ;
D0 2 ;
#10 = #10 + #4 ;
IF [ ABS [ #10 ] GE [ABS [ #1 ] ] ] GOTO 1 ;
G01 X #11 ;
G00 X #6 ;
#11 = #4 - #6 ;
END 2 ;
N1 G01 X#1 − #10 + #11 ;
IF [ #15 EQ 0 ] GOTO 20 ;
IF [ #16 EQ 0 ] GOTO 21 ;
N20 G00 Y#5 ;
N21 #16 = 1 ;
G00X - #1 ;
IF [ #14 ] GOTO 3 ;
#12 = #12 + #3 ;
IF [ ABS [ #12 ] LT [ABS [ #2 ] ] ] GOTO 2 ;
#14 = 1 ;
#13 = #2 - #12 + #13 ;
N2 G00 Y #13 ;
#13 = #3 - #5 ;
END 1 ;
N3 G00 Y - #2 - #5 ;
M99 ;
IV - 10
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
G. 1 ;
1F [ ABS [ #1 ] GT 0 ] GOTO 10 ;
#14 = 1 ;
N10 #13 = #4 ;
IF [ #15 NE 0 ] GOTO 11 ;
#13 = #4 - #5 ;
N11 #16 = 0 ;
D0 1 ;
#10 = 0 ;
#11 = #3 ;
D0 2 ;
#10 = #10 + #3 ;
IF [ ABS [ #10 ] GE [ABS [ #2 ] ] ] GOTO 1 ;
G01 Y #11 ;
G00 Y #6 ;
#11 = #3 - #6 ;
END 2 ;
N1 G01 Y#2 - #10 + #11 ;
IF [ #15 EQ 0 ] GOTO 20 ;
IF [ #16 EQ 0 ] GOTO 21 ;
N20 G00 X#5 ;
N21 #16 = 1 ;
G00Y - #2 ;
IF [ #14 ] GOTO 3 ;
#12 = #12 + #4 ;
IF [ ABS [ #12 ] LT [ABS [ #1 ] ] ] GOTO 2 ;
#14 = 1 ;
#13 = #1 - #12 + #13 ;
N2 G00 X #13 ;
#13 = #4 - #5 ;
END 1 ;
N3 G00 X - #1 - #5 ;
M99 ;
IV - 11
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
G. 1 ;
#3003 = #8 OR 1 ;
G0 X #1 ;
G1 Y #2 ;
G0 Y − #2 ;
X #5 ;
1F [ #3 EQ 0 ] GOTO 1 ;
G1 X - #3 Y #4 ;
N1 G1 Y#6 ;
X - #7 ;
G0Y - #2 ;
X - #5 ;
1F [ #3 EQ 0 ] GOTO 2 ;
G1 X #3 Y #4 ;
N2 G1 Y#6 ;
X #7 ;
#3003 = #8 ;
G0Y - #2 ;
M99 ;
G. 1 ;
#12 = 1 ;
#13 = #9 ;
1F [ ABS [ #13 ] GE [ ABS [ #8 ] ] ] GOTO 1 ;
#16 = 1 ;
#13 = #8 ;
N1 #11 = #13 ;
1F [ ABS [ #11 ] LT [ ABS [ #4 − #5 ] ] ] GOTO 2 ;
#11 = #4 - #5 ;
#14 = 1 ;
N2 #17 = #11 ;
#18 = ROUND [ [ #4 - #11 - #5 ] ∗ #7 ] ;
IF [ [ #18 XOR #1 ] GE 0 ] GOTO 10 ;
#18 = - #18 ;
N10 #19 = #18 ;
#10 = ROUND [ [ #11 + #5 ] ∗ #7 ] ;
IF [ [ #10 XOR #1 ] GE 0 ] GOTO 20 ;
#10 = - #10 ;
N20 G00 X#10 ;
#20 = #10
D0 1 ;
#15 = ROUND [ #10 ∗ #3/#1 ] ;
G00 Y #2 + #3 - #4 - #15 + #11 ;
G33 X#1 - #10 - #18 Y -#3 + #15 ;
G00 Y - #2 + #4 − #11 ;
IF [ #14 GT 0 ] GOTO 3 ;
IF [ #16 GT 0 ] GOTO 7 ;
#12 = #12 + 1 ;
#13 = ROUND [ #9 ∗ SQRT [ #12 ] ] ;
IV - 12
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
G. 1 ;
N761 !L10
#12 = 1 ;
#13 = #9 ;
1F [ ABS [ #13 ] GE [ ABS [ #8 ] ] ] GOTO 1 ;
#16 = 1 ;
#13 = #8 ;
N1 #11 = #13 ;
1F [ ABS [ #11 ] LT [ ABS [ #4 − #5 ] ] ] GOTO 2 ;
#11 = #4 - #5 ;
#14 = 1 ;
N2 #17 = #11 ;
#18 = ROUND [ [ #4 - #11 - #5 ] ∗ #7 ] ;
IF [ [ #18 XOR #1 ] GE 0 ] GOTO 10 ;
#18 = - #18 ;
N10 #19 = #18 ;
#10 = ROUND [ [ #11 + #5 ] ∗ #7 ] ;
IV - 13
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
IV - 14
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
2-system simultaneous
G76.2 (O762)
compound thread cutting cycle
G. 1 ;
N762 !L10 ;
#12 = 1 ;
#13 = #9 ;
1F [ ABS [ #13 ] GE [ ABS [ #8 ] ] ] GOTO 1 ;
#16 = 1 ;
#13 = #8 ;
N1 #11 = #13 ;
1F [ ABS [ #11 ] LT [ ABS [ #4 - #5 ] ] ] GOTO 2 ;
#11 = #4 - #5 ;
#14 = 1 ;
N2 #17 = #11 ;
#18 = ROUND [ [ #4 - #11 - #5 ] ∗ #7 ] ;
IF [ [ #18 XOR #1 ] GE 0 ] GOTO 10 ;
#18 = - #18 ;
N10 #19 = #18 ;
#10 = ROUND [ [ #11 + #5 ] ∗ #7 ] ;
IF [ [ #10 XOR #1 ] GE 0 ] GOTO 20 ;
#10 = - #10 ;
N20 IF [# 27 NE 1 ] GOTO 21 ;
G00 X#10 ;
N21 #20 = #10 ;
#28 = 1 ;
D01 ;
#15 = ROUND [ #10 ∗ #3/#1 ] ;
#29 = #28 MOD 2 ;
IF [ [ #27 EQ 1 ] AND [#29 EQ 0 ] GOTO 22 ;
IF [ [ #27 EQ 2 ] AND [#29 EQ 1 ] GOTO 22 ;
G00 Y #2 + #3 - #4 - #15 + #11 ;
!L11 ;
G33 X#1 - #10 - #18 Y -#3 + #15 ;
G00 Y - #2 + #4 - #11 ;
#21 = #18 ;
!L12 ;
N22 IF [ #14 GT 0 ] GOTO 3 ;
IF [ #16 GT 0 ] GOTO 7 ;
#12 = #12 + 1 ;
#13 = ROUND [ #9 ∗ SQRT [ #12 ] ] ;
IF [ ABS [ #13 - #11 ] GE [ ABS [ #8 ] ] ] GOTO 8 ;
#16 = 1 ;
N7 #13 = #11 + #8 ;
N8 #11 = #13 ;
IF [ ABS [ #11 ] LT [ ABS [ #4 - #5 ] ] ] GOTO 9 ;
#11 = #4 - #5 ;
#14 = 1 ;
N9 #10 = ROUND [ [ #17 - #11 ] ∗ #7 ] ;
IF [ [ #10XOR#1] GE 0 ] GOTO 6 ;
#10 = -#10 ;
N6 #10 = #10 + #20 ;
IF [ [ #27 EQ 1 ] AND [#29 EQ 1 ] GOTO 24 ;
IF [ [ #27 EQ 2 ] AND [#29 EQ 0 ] GOTO 24 ;
IF [ [ #27 EQ 2 ] AND [#28 EQ 1 ] GOTO 23 ;
G00 X − #1 + #10 + #21 ;
IV - 15
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
GOTO 24 ;
N23 G00 X#10 ;
N24 IF [ #14 LT 0 ] GOTO 11 ;
#18 = 0 ;
GOTO 12 ;
N11 #18 = #19 - #10 + #20 ;
N12 #28 = #28 + 1 ;
END 1 ;
N3 IF [ ABS [ #6 ] LT 1 ] GOTO 5 ;
#14 = 0 ;
#13 = 0 ;
D0 2 ;
IF [ #14 GT 0 ] GOTO 5 ;
#13 = #13 + #6 ;
IF [ ABS [ #13 ] LT [ ABS [ #5 ] ] ] GOTO 4 ;
#13 = #5 ;
#14 = 1 ;
N4 #29 = #28 MOD 2 ;
IF [ [ #27 EQ 1 ] AND [#29 EQ 1 ] GOTO 25 ;
IF [ [ #27 EQ 2 ] AND [#29 EQ 0 ] GOTO 25 ;
G00 X #10 - #1 + #21 ;
#21 = 0 ;
G00 Y #2 + #3 − #4 + #13 - #15 + #11 ;
!L11 ;
G33 X #1 - #10 Y − #3 + #15 ;
G00 Y - #2 + #4 - #13 - #11 ;
!L12 ;
N25 #28 = #28 + 1 ;
END 2 ;
N5 G00 X - #1 ;
M99 ;
%
G. 1 ;
1F [ [ #1 EQ 0 ] OR [ #2 EQ 0 ] ] GOTO 1 ;
Y #2 + #7 ;
G1 X #1 Y - #7 ;
Y - #2 ;
G0 X - #1 ;
N1 M99 ;
G. 1 ;
1F [ [ #1 EQ 0 ] OR [ #2 EQ 0 ] ] GOTO 1 ;
Y #2 + #7 ;
G33 X #1 Y - #7 F #9 E #10 ;
G0 Y - #2 ;
X - #1 ;
N1 M99 ;
IV - 16
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
G. 1 ;
1F [ [ #1 EQ 0 ] OR [ #2 EQ 0 ] ] GOTO 1 ;
X #1 + #7 ;
G1 X - #7 Y #2 ;
X - #1 ;
G0 Y - #2 ;
N1 M99 ;
G83
(O830) Deep hole drilling cycle B
G87
G. 1 ;
1F [ #30 ] GOTO 2 ;
M #24 ;
#29 = #11 #28 = 0 ;
Z #2 ;
#2 = ##5 #3003 = #8 OR 1 ;
D0 1 ;
#28 = #28 − #11 #26 = - #28 - #29 ;
Z #26 ;
IF [ ABS [ #28 ] GE [ ABS [ #3 ] ] ] GOTO 1 ;
G1 Z #29 ;
G0 Z #28 ;
G29 = #11 + #14 ;
END 1 ;
N1 G1 Z #3 - #26 ;
G4 P #4 ;
#3003 = #8 ;
G0Z - #3 - #2 ;
IF [#24 EQ #0 ] GOTO 2 ;
M #24 + 1 ;
G4 P #21 ;
N2 M99 ;
IV - 17
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
G83
(O831) Deep hole drilling cycle A
G87
G. 1 ;
1F [ #30 ] GOTO 2 ;
M #24 ;
#29 = #0 #28 = #11 ;
Z #2 ;
#2 = ##5 #3003 = #8 OR 1 ;
D0 1 ;
#29 = #29 + #11 ;
IF [ ABS [ #29 ] GE [ ABS [ #3 ] ] ] GOTO 1 ;
G1 Z #28 ;
G0 Z - #14 ;
#28 = #11 + #14 ;
END 1 ;
N1 G1 Z #3 - #29 + #28 ;
G4 P #4 ;
#3003 = #8 ;
G0Z - #3 - #2 ;
IF [#24 EQ #0 ] GOTO 2 ;
M #24 + 1 ;
G4 P #21 ;
N2 M99 ;
G. 1 ;
1F [ #30 ] GOTO 3 ;
#3003 = #8 OR 1 ;
#29 = #12 #28 = 0 ;
G0 Z #2 ;
IF [ #12 NE #0 ] GOTO 1 ;
IF [ #11 EQ #0 ] GOTO 2 ;
N1 #28 = #28 - #12 #26 = - #28 - #29 ;
IF [ ABS [ #28 ] GE [ ABS [ #3 ] ] ] GOTO 2 ;
G1 Z #12 ;
G4 P #4 ;
G0 Z #28 - #2 ;
G4P # 13 ;
G29 = #11 + #15 ;
D0 1 ;
#28 = #28 - #11 #26 = - #28 - #29 ;
G0 Z #26 + #2 ;
IF [ ABS [ #28 ] GE [ ABS [ #3 ] ] ] GOTO 2 ;
G1 Z #29 ;
G4 P #4 ;
G0 Z #28 - #2 ;
G4 P # 13 ;
END 1 ;
N2 G1 Z #3 - #26 ;
G4 P #4 ;
#3003 = #8 ;
G0Z - #3 - #2 ;
N3 M99 ;
IV - 18
Appendix 4. Registering/Editing the Fixed Cycle Program
4.3 Standard Fixed Cycle Subprogram (For L system)
G84
(O840) Tap cycle
G88
G. 1 ;
1F [ #30 ] GOTO 2 ;
M #24 ;
Z #2 ;
#2 = ##5 #3003 = #8 OR 1 #3004 = #9 OR 3 ;
G1 Z #3 ;
G4 P #4 ;
M4 ;
#3900 = 1 ;
G1 Z - #3 ;
#3004 = #9 ;
M3 ;
#3003 = #8 ;
IF [#24 EQ #0 ] GOTO 1 ;
M #24 + 1 ;
G4 P #21 ;
N1 G0 Z − #2 ;
N2 M99 ;
G85
(O850) Boring cycle
G89
G. 1 ;
1F [ #30 ] GOTO 2 ;
M #24 ;
Z #2 ;
#2 = ##5 #3003 = #8 OR 1 ;
G1 Z #3 ;
G4 P #4 ;
#3003 = #8 ;
Z - #3 F #23 ;
F #22 ;
IF [#24 EQ #0 ] GOTO 1 ;
M #24 + 1 ;
G4 P #21 ;
N1 G0 Z − #2 ;
N2 M99 ;
IV - 19
Appendix 4. Registering/Editing the Fixed Cycle Program
4.4 Standard Fixed Cycle Subprogram (For M system)
IV - 20
Appendix 4. Registering/Editing the Fixed Cycle Program
4.4 Standard Fixed Cycle Subprogram (For M system)
G0 Z#28 ; Return.
#29 = #11 + #14 ; Define the cutting amount for block 2 and after.
END1 ;
N1 G1 Z#3 - #26 ; Cutting feed
#3003 = #8 ;
G0 Z - #3 - #2 ; Return.
N2 M99%
IV - 21
Appendix 4. Registering/Editing the Fixed Cycle Program
4.4 Standard Fixed Cycle Subprogram (For M system)
IV - 22
Appendix 4. Registering/Editing the Fixed Cycle Program
4.4 Standard Fixed Cycle Subprogram (For M system)
IV - 23
Appendix 4. Registering/Editing the Fixed Cycle Program
4.4 Standard Fixed Cycle Subprogram (For M system)
IV - 24
Appendix 4. Registering/Editing the Fixed Cycle Program
4.4 Standard Fixed Cycle Subprogram (For M system)
IV - 25
Appendix 5. RS-232C I/O Device Parameter Setting Examples
IV - 26
Appendix 6. Alarms
6.1 List of Alarms
Appendix 6. Alarms
6.1 List of Alarms
6.1.1 Operation Alarms
IV - 27
Appendix 6. Alarms
6.1 List of Alarms
IV - 28
Appendix 6. Alarms
6.1 List of Alarms
IV - 29
Appendix 6. Alarms
6.1 List of Alarms
IV - 30
Appendix 6. Alarms
6.1 List of Alarms
IV - 31
Appendix 6. Alarms
6.1 List of Alarms
IV - 32
Appendix 6. Alarms
6.1 List of Alarms
IV - 33
Appendix 6. Alarms
6.1 List of Alarms
IV - 34
Appendix 6. Alarms
6.1 List of Alarms
IV - 35
Appendix 6. Alarms
6.1 List of Alarms
IV - 36
Appendix 6. Alarms
6.1 List of Alarms
IV - 37
Appendix 6. Alarms
6.1 List of Alarms
Alarm Unclamp In dwell Alarm Door Waiting Alarm Waiting Waiting Waiting Waiting
No. signal execu- No. open for No. for for for rapid for MSTB
wait tion spindle spindle cutting traverse comp-
position orienta- speed decelera- letion
to be tion to decelera- tion
(Note 2) (Note 1) looped complete tion
0 0 0
1 × 1 × 1 ×
8 × 8 × 2 ×
9 × × 9 × × 3 × ×
4 ×
5 × ×
6 × ×
7 × × ×
8 ×
9 × ×
A × ×
B × × ×
C × ×
D × × ×
E × × ×
F × × × ×
IV - 38
Appendix 6. Alarms
6.1 List of Alarms
(Note 2) The resetting method may change according to the alarm class.
For example, even if "S03 SERVO ALARM: NR" is displayed, it may be necessary to turn the NC
power ON again.
IV - 39
Appendix 6. Alarms
6.1 List of Alarms
IV - 40
Appendix 6. Alarms
6.1 List of Alarms
IV - 41
Appendix 6. Alarms
6.1 List of Alarms
IV - 42
Appendix 6. Alarms
6.1 List of Alarms
IV - 43
Appendix 6. Alarms
6.1 List of Alarms
IV - 44
Appendix 6. Alarms
6.1 List of Alarms
IV - 45
Appendix 6. Alarms
6.1 List of Alarms
IV - 46
Appendix 6. Alarms
6.1 List of Alarms
IV - 47
Appendix 6. Alarms
6.1 List of Alarms
Alarm No.
Error No.
Message
Class
IV - 48
Appendix 6. Alarms
6.1 List of Alarms
(Note) When two or more "Y02 System alarms" occur at the same time, only the alarm which occurs first is
displayed.
IV - 49
Appendix 6. Alarms
6.1 List of Alarms
IV - 50
Appendix 6. Alarms
6.1 List of Alarms
(Alarm No.)
0 0
IV - 51
Appendix 6. Alarms
6.1 List of Alarms
(Alarm No.)
0 0
IV - 52
Appendix 6. Alarms
6.1 List of Alarms
(Alarm No.)
0 0
IV - 53
Appendix 6. Alarms
6.1 List of Alarms
IV - 54
Appendix 6. Alarms
6.1 List of Alarms
IV - 55
Appendix 6. Alarms
6.1 List of Alarms
IV - 56
Appendix 6. Alarms
6.1 List of Alarms
0 0 1 ×
No.1 spindle
2 ×
No.2 spindle
3 × ×
4 ×
No.3 spindle
5 × ×
No.4 spindle
6 × ×
7 × × ×
Alarm
Details Remedy
No.
0001 There is an error in the spindle encoder signal. • Check the spindle encoder's feedback cable
to The data transmission to the drive unit is stopped and the encoder.
0007 when this error occurs.
IV - 57
Appendix 6. Alarms
6.1 List of Alarms
Warning No.
Message
(Note) If warning No. 0001, 0002, 0003, or 000A is displayed, set the parameters, then turn power OFF and
turn it ON again.
IV - 58
Appendix 6. Alarms
6.1 List of Alarms
IV - 59
Appendix 6. Alarms
6.1 List of Alarms
! CAUTION
If the battery low warning is issued, save the machining programs, tool data and parameters in an
input/output device, and then replace the battery. When the battery alarm is issued, the machining
programs, tool data and parameters may be destroyed. Reload the data after replacing the battery.
Do not replace the battery while the power is ON.
Do not short circuit, charge, heat, incinerate or disassemble the battery.
Dispose of the spent battery following local laws.
(Note 1) The display of Z52 battery fault 0001 can be removed by resetting. However, the warning state will
not be cancelled until the battery is replaced.
(Note 2) Temperature warning
If the alarm is displayed when an overheat alarm is detected‚ the overheat signal will be output
simultaneously. If the machine is in automatic operation‚ the operation will be continued‚ but
restarting will not be possible after resetting or stopping with M02/M30. (Starting will be possible
after block stop or feed hold.) The alarm will be reset and the overheat signal will turn OFF when the
temperature drops below the specified temperature.
76543210
PLC parameter bit selection #6449
Communication terminal
(setting and display unit) 0: Detection invalid
Controller 1: Detection valid
IV - 60
Appendix 6. Alarms
6.1 List of Alarms
Alarm RIO RIO RIO RIO Alarm RIO RIO RIO RIO
number (seventh (sixth (fifth (fourth number (third (second (first (0th
station) station) station) station) station) station) station) station)
0 0
1 × 1 ×
2 × 2 ×
3 × × 3 × ×
4 × 4 ×
5 × × 5 × ×
6 × × 6 × ×
7 × × × 7 × × ×
8 × 8 ×
9 × × 9 × ×
A × × A × ×
B × × × B × × ×
C × × C × ×
D × × × D × × ×
E × × × E × × ×
F × × × × F × × × ×
This also applies for the remote I/O 1st part system communication interrupted station, remote I/O 3rd part
system communication interrupted station and board connection remote I/O communication interrupted
station.
IV - 61
Appendix 6. Alarms
6.1 List of Alarms
(Note 4)
Z60 Fieldbus communication error n1 n2 n3 n4
Classification No.
Message
Class.
Details
No.
n1 Shows state of the master channel (shown in hexadecimal number)
00: Offline In initializing
40: Stop Cutting I/O communication
80: Clear Resetting output data of each slave by sending 0 data.
C0: In operation In I/O communication
n2 Shows error state (shown in hexadecimal number)
Bit 7 6 5 4 3 2 1 0
BIT Details
0 Control error: Parameter error
1 Auto clear error: Communication with all the slave channels was cut because
a communication with one slave channel had an error.
2 Non exchange error: Slave channel with communication error is found
3 Fatal error: The communication cannot be continued because sever network
failure exists.
4 Event error: Short-circuit was found on the network.
5 Not ready: CNC communication is not ready.
6 Time out error: Time out was detected in communication with each channel.
7 Not used
IV - 62
Appendix 6. Alarms
6.1 List of Alarms
(a) Error in master channel (when remote address with an error is FF (hexadecimal number))
Value in
Details Remedy
n3
0 No error Operating normally
32 No USR_INTF-task Damage in HN571. Replace HN571.
33 No global data field
34 No FDL-task
35 No PLC-task
37 Master parameter incorrect
39 Slave parameter incorrect
3C Data offset exceeding allowable set Check the configuration setting.
value received
3D Slave data send range overlap
3E Slave data receive range overlap
3F Not set data hand shake Damage in HN571. Replace HN571.
40 RAM range exceeded
41 Slave parameter data set illegal
CA No segment
D4 Data base read illegal Download the configuration data again.
D5 Operating system illegal Damage in HN571. Replace HN571.
DC Watch dog error
DD Hand shake mode
No data communication by 0
DE Master auto clear mode When setting auto clear mode, the auto clear
mode was performed because one slave was
not able to connect in run time.
(b) Error in slave channel (when remote address with an error is other than FF (hexadecimal
number))
Value in
Details Remedy
n4
2 Station overflow reported Check the configuration of slave channel in
3 Station stopped responding to which error has occurred. Check if there is
master command any short-circuit in wire to bus.
9 No slave required responding data
11 No station respond
12 No master to logical token ring
15 Illegal parameter requested
IV - 63
Appendix 6. Alarms
6.1 List of Alarms
IV - 64
Appendix 6. Alarms
6.1 List of Alarms
(Note) To release alarm "Z70 Abs data error", enter the parameter data output when establishing the
absolute position and turn ON the power again. For the rotary axis, however, the alarm cannot be
released by entering the parameter data.
IV - 65
Appendix 6. Alarms
6.1 List of Alarms
(Note) When this alarm occurs, do not turn OFF the drive unit power to protect the absolute position data.
Replace the battery while the drive unit power is ON.
IV - 66
Appendix 6. Alarms
6.1 List of Alarms
Error No.
Message
Alarm class
IV - 67
Appendix 6. Alarms
6.1 List of Alarms
IV - 68
Appendix 6. Alarms
6.1 List of Alarms
IV - 69
Appendix 6. Alarms
6.1 List of Alarms
IV - 70
Appendix 6. Alarms
6.1 List of Alarms
The tolerable regeneration power of the internal • Set the parameter #50002 correctly.
regenerative resistor or external regenerative option was • Connect correctly.
exceeded. • Lower the positioning frequency.
• Change the regenerative option to
a larger capacity.
• Lower the load.
• Review the power supply.
Regenerative transistor error • Replace the servo drive unit.
IV - 71
Appendix 6. Alarms
6.1 List of Alarms
Alarm
Details Remedy
information
0033 Aux ax overvoltage • Wire correctly.
The voltage of the converter in the servo drive unit was • Replace the servo drive unit.
400V or more. • For the internal regenerative
resistor, replace the drive unit.
• For the external regenerative option,
replace the regenerative option.
0046 Aux ax motor overheating • Reduce the motor load.
An operation state causing the motor to overheat • Review the operation pattern.
continued.
0050 Aux ax overload 1 • Reduce the motor load.
The servo drive unit or servomotor overload protection • Review the operation pattern.
function activated. • Change to a motor or drive unit
with large output.
• Change the setting of the
automatic tuning response
characteristics.
• Correct the connection.
• Replace the servomotor.
IV - 72
Appendix 6. Alarms
6.1 List of Alarms
00E9 Aux ax main circuit OFF warning • Turn ON the main circuit power.
The servo ON signal was input while the main circuit
power was OFF.
The contactor operation is faulty.
IV - 73
Appendix 6. Alarms
6.1 List of Alarms
IV - 74
Appendix 6. Alarms
6.1 List of Alarms
IV - 75
Appendix 6. Alarms
6.1 List of Alarms
IV - 76
Appendix 6. Alarms
6.1 List of Alarms
Message
Alarm class
IV - 77
Appendix 6. Alarms
6.1 List of Alarms
Sub-status
Message Details Remedy
1 2
U01 - - PLC program is not input. Download the PLC program of the
No user (Note) Emergency stop (EMG) will format selected with the PLC
PLC be applied. environment selection parameters
(bit selection #51/bit 4).
U10 0x0010 - PLC scan time error Edit the PLC program size to a
Illegal PLC The scan time is 1 second or smaller size.
longer.
0x0040 - PLC program operation mode Download the PLC program
illegal having the same format as when
PLC program different from the the power was reset or turned
designated mode was ON.
downloaded.
(Note) Emergency stop (EMG) will
be applied.
0x0080 - GPPW ladder code error Download the correct GPPW
(Note) Emergency stop (EMG) will format PLC program.
be applied.
0x008x - PLC4B ladder code error Download the correct PLC4B
An illegal circuit was found in the format PLC program.
PLC4B ladder.
bit1: PC medium-speed circuit
illegal
bit2: PC high-speed circuit illegal
(Note) Emergency stop (EMG) will
be applied.
0x0400 Number of Software illegal interrupt Turn the power ON again.
ladder The PLC program process stopped If the error is not reset, download
steps abnormally due to an illegal the correct PLC program.
software command code.
(Note) Emergency stop (EMG) will
be applied.
IV - 78
Appendix 6. Alarms
6.1 List of Alarms
Sub-status
Message Details Remedy
1 2
U10 0x800x Number of Software exception
Illegal PLC PLC The PLC program process stopped
program abnormally due to a bus error, etc.
steps bit 0: BIN command operation error Refer to the methods for using the
bit 1: BCD command operation BCD and BIN function
error commands.
bit6: CALL/CALLS/RET Turn the power ON again.
command error If the error is not reset, download
bit7: IRET command execution the correct PLC program.
error
(Note) Emergency stop (EMG) is
applied for bit 6/7.
U50 The PLC program is stopped. Start the PLC program.
PLC
stopped
U55 The PLC program is stopped and not Write the PLC program into ROM.
PLC written into ROM.
stopped /
is not
saved
U60 The PLC program is not written into Write the PLC program into ROM.
Ladder is ROM.
not saved
(Note) The number of PLC program steps displayed on the screen may not match the actual number of error
occurrence steps because of the PLC program timing. Use this as a guideline of the occurrence
place.
IV - 79
Appendix 6. Alarms
6.1 List of Alarms
IV - 80
Appendix 6. Alarms
6.2 Operation Messages
IV - 81
Appendix 6. Alarms
6.2 Operation Messages
IV - 82
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Program check not possible • Graphic check was attempted during the Computer link B operation.
Execute check search • The program check is disabled. Execute the check search.
Solid check disabled (memory • The 3D program check is disabled due to the memory shortage.
shortage) Separate the programs and execute the check drawing again.
Press the menu [Work init] once before performing the check
drawing again.
IV - 83
Appendix 6. Alarms
6.2 Operation Messages
IV - 84
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Can't close file for dev A • Contact the service center
Can't open directory for dev B • Could not find a directory corresponding to device B.
Different devices designated in A • The same device must be designated for devices A and B, but
and B differing devices were designated.
Timeout error • A timeout error occurred when communicating with the external
device.
Checking • Cannot be executed during a check
Make directory complete • Creation of the directory has been completed.
IV - 85
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Merge complete • The data merge completed.
Merge execution • The data merge is being executed.
Memory alloc error • Securing of the communication data range failed.
Rename complete • The rename has been completed.
• Message to confirm the operation.
OK? (Y/N)
[Y] or [INPUT] : Execute the operation
[N] : Cancel the operation.
I/O not ready • An error occurred between the NC and the external device.
I/O parameter error • The external device settings and input/output parameters do not
match.
I/O port busy • Input/output was not possible as the I/O port is busy.
FD write protect • The FD is write-protected.
Release the write protection.
PLC running • An attempt was made to input a user PLC during PLC RUN.
• Stop the PLC on the maintenance screen.
FD not ready • An attempt was made to perform an FD operation search with no FD.
• An attempt was made to display the FD list with no FD.
MemoryCard not ready • An attempt was made to perform operations with no memory card.
DS not ready • An attempt was made to perform operations with no data server.
Can't write in READ-ONLY file • Contact the service center.
Condense complete • Condensing has been completed.
A directory does not exist • The specified directory does not exist.
Setting complete normally • Decryption code setting file of the credit system was set normally.
IV - 86
Appendix 6. Alarms
6.2 Operation Messages
IV - 87
Appendix 6. Alarms
6.2 Operation Messages
TLM axis is illegal • During 2 or more axes movement, the tool length measurement was
executed by turning the sensor ON. Keep the tool away from the
sensor and execute the measurement by one axis.
TLM axis not returned to ref. • The tool length measurement was executed by tuning the sensor ON
position for the axis in which dog-type reference point return has not been
executed. Carry out reference point return for the measurement axis.
Can't write rotation parameter • The measured result cannot be set in the process parameter.
IV - 88
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Can't calculate center & angle for • Three points necessary for calculation are not retrieved.
rot • Center shift amount or censor radius was failed to retrieve.
• Calculation of the center and the angle was failed.
Input 0 to coord center & angle • The center and the angle are not "0".
for rot Set "0" in the parameter "#8623 Coord rot centr (H)", "#8624 Coord
rot centr (V)" and "#8627 Coord rot angle".
Can't calculate • Hole center cannot be determined.
Meas axis not returned to ref. • The workpiece measurement was executed when dog-type reference
position point return has not been executed. Carry out reference point return
for the measurement axis.
IV - 89
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Exists in spindle/standby. Set? • An attempt was made to set the same No. as the tool No. for
(Y/N) spindle/standby.
Exists in magazine 1. Set? (Y/N) • An attempt was made to set the same No. as the tool No. that has
been registered to the valid magazine.
Exists in magazine 2. Set? (Y/N) • An attempt was made to set the same No. as the tool No. that has
been registered to the valid magazine.
Exists in magazine 3. Set? (Y/N) • An attempt was made to set the same No. as the tool No. that has
been registered to the valid magazine.
Exists in magazine 4. Set? (Y/N) • An attempt was made to set the same No. as the tool No. that has
been registered to the valid magazine.
Exists in magazine 5. Set? (Y/N) • An attempt was made to set the same No. as the tool No. that has
been registered to the valid magazine.
IV - 90
Appendix 6. Alarms
6.2 Operation Messages
Can't write into file • Could not write the data to the memory with the buffer correction.
Contact the service center.
Overwrite this file?(Y/N) • Message to confirm when registering MDI
[Y] or [INPUT] : Overwrite the file.
[N] : Do not overwrite the file.
Memory over • The program cannot be written, because the memory capacity will be
exceeded.
Designated character string not • Could not find the search results and character string in the program.
found
Save current file ?(Y/N) • Message to confirm the saving.
[Y] : Save the changes to the current file.
[N] : Do not save the changes to the current file.
A file does not exist • An attempt was made to select and edit a non-existent file.
Executing • Following menu's process is executing now:
"Line paste", "Line clear", "Undo", "String search", "String replace",
"Miss warning", or "Next miss".
Designated file does not exist • An attempt was made to select and erase a non-existent file.
Erase complete • The data erasing completed.
Can't erase designated file • The selected file cannot currently be erased.
Designated file does not exist • A file that does not exist was designated when file editing.
Designated file already exists • When creating a new file, a file name was designated that already
exists.
Replace? (Y/N) • Message to confirm the character string replacement.
[Y] or [INPUT] : Replace the character string.
[N] : Do not replace the character string.
File access error • Contact the Service Center.
File open error • The designated file is already open.
Editing • A program is being edited on the screen.
Save the program to write it into the memory.
Program entry over • The program could not be registered in the memory when attempted,
because the No. of registrations designated in the specifications
would be exceeded.
Block char nos over • The character number limitation in one block was exceeded.
Paste error • Pasting was attempted within the copy range of the same file.
Copy range is inadequate • The copy range designation is inadequate.
Check whether the designated range exists.
• The range was designated exceeding 100 lines during mass editing.
Area designation is inadequate • The area designation is inadequate.
Check whether the designated area exists.
Designated line is out of • Designation was attempted of a line No. larger than the No. of lines in
program range the entire program.
IV - 91
Appendix 6. Alarms
6.2 Operation Messages
Message Details
MDI no setting • Editing of the MDI was started, but the MDI setting was incomplete.
Abs/Inc mode is illegal • During playback editing:
G90 was set when control parameter "Playback G90" was OFF.
G91 was set when control parameter "Playback G90" was ON.
MDI search complete • The MDI search completed.
Can't search in MDI mode • The restart search was attempted during MDI mode.
• Execute the restart search after switching other than MDI mode.
MDI Set ended • MDI setting cannot be executed.
MDI Setting error • MDI setting was completed.
MDI search error • Could not execute the MDI search.
MDI entry complete • MDI entry has been completed.
Can't edit except in MDI mode • "#1144 mdlkof" (MDI setting lock) is "0" and therefore it is not possible
to edit the MDI program in a mode other than MDI mode.
Input miss was detected • An input miss was detected.
Input miss was not detected • A search was performed for an input miss, however, none was found.
Can't edit a file except in NC • Editing cannot be performed at the edit window for programs other
memory than those in the NC memory.
Save it • The cursor was tried to move beyond the editable range during
mass-editing. Save, then operate again.
Save not possible • A special file (history file etc.) that cannot be saved was edited and an
attempt was made to save it. Perform an operation to quit editing.
• Failed saving due to file size over, etc. during mass-editing.
• Setting of "#1166 fixpro" was illegal. Use the settings for a regular
program.
• MDI cannot be entered due to MDI editing mode. Press INPUT key
and finish editing.
Save left side file? (Y/N) • Message to confirm whether saving the left side file of the
multi-program display type
[Y]: Save the change
[N]: Do not save the change
Save right side file? • Message to confirm whether saving the right side file of the
(Y/N) multi-program display type
[Y]: Save the change
[N]: Do not save the change
Can't edit because of size over • The program cannot be written, because the memory capacity will be
exceeded.
• If the memory capacity of the transfer designation device is exceeded
during the automatic backup, increase the available memory of the
device.
Can't edit the searched file • The serial file cannot be edited.
DS not ready • Operation was attempted when a DS was not inserted.
• Creating or opening a program was attempted when a DS was not
inserted.
FD not ready • The FD operation search was attempted when an FD was not
inserted.
• The FD list display was attempted when an FD was not inserted.
• Creating or opening a program was attempted when an FD was not
inserted.
IV - 92
Appendix 6. Alarms
6.2 Operation Messages
Message Details
MemoryCard not ready • Operation was attempted when a memory card was not inserted.
This cannot be specified • Invalid special characters (/E, etc.) were set.
Loading • Loading file.
Saving • Saving file.
Can't execute playback edit • The playback editing cannot be executed because the right side
area is mass-editing mode.
• Playback editing was attempted while program file to be edited is not
designated. Display a program file in the right side area.
Program display lock C • The program display or search cannot be executed. Review the
parameter "#1121 pglk_c" (program display lock).
IV - 93
Appendix 6. Alarms
6.2 Operation Messages
Change Ope. test mode • Operation of the Operation test screen was attempted when the
operation adjustment mode was not selected.
Test mode sig valid signal is now • The operation adjustment mode cannot be selected because the
OFF operation adjustment mode valid signal (R9998/bit0) is 0.
IV - 94
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Auto adjust complete • Analog output adjustment completed normally.
Auto adjust execution • Performing analog output adjustment normally.
Execute? (Y/N) • Message to confirm the operation
[Y] or [INPUT] : The currently selected operation is performed.
[N] : The currently selected operation is not performed.
Unit not equipped • The machine is not equipped with an analog output unit.
A serial number is inaccurate • The system data to be restored and the serial number in the NC do
not match, and therefore it is not possible to restore.
• Check to ensure that the serial number in the NC has been set and
that the system data to be restored matches.
Operating aux axis • It is not possible to set parameter and input/output data during
auxiliary axis operation.
• It is not possible to change the display axis during auxiliary axis
operation.
IV - 95
Appendix 6. Alarms
6.2 Operation Messages
Input the axis name • This appears when the data type is selected in the Ch1 or Ch2 data
setting area.
Input the name of the axis to be sampled.
Input axis name/signal No./bit • This appears when the data type is selected in the Ch1 or Ch2 data
setting area.
Set the sampling conditions common for Ch1 and Ch2.
Input device name/device No. • Input device name/device No.
Input file/sub-ID/item/data • This appears when an NC file is selected in the Ch1 or Ch2 data
setting area.
Change the area • Change the area.
Sampling conditions are illegal • The data cannot be sampled as the setting conditions are illegal.
Review the data, vertical scale, sampling rate and horizontal scale on
the Condition setting screen.
Can't start sampling • "#1224 aux08/bit0" is "0" and sampling start-up cannot be performed.
The collection invalid • The parameters are set to prevent data being collected. Check the
parameters.
The collection begin? • Determines whether to start data collection. Press [Y] or [INPUT] to
start data collection.
The collection stop? • Determines whether to stop data collection. Press [Y] or [INPUT] to
stop data collection.
The collection is being executed • An attempt was made to start data collection while data collection
was being performed.
The collection is stopping • An attempt was made to stop data collection while data collection was
stopped.
The collection invalid • The data collection is set invalid in the parameter. Check the
parameter.
Scroll execution • The waveform display is being scrolled.
IV - 96
Appendix 6. Alarms
6.2 Operation Messages
IV - 97
Appendix 6. Alarms
6.2 Operation Messages
IV - 98
Appendix 6. Alarms
6.2 Operation Messages
IV - 99
Appendix 6. Alarms
6.2 Operation Messages
IV - 100
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Dialing Do not turn the power OFF • Data is being transmitted with one-touch call.
until the one-touch call • Communication will start when one-touch call is
executed, but the line is not connected yet in
ends.
this state.
• This state is also entered when standing by for
transmission.
Waiting for dialing Do not turn the power OFF • Redialing since the NC service is using the line
until the one-touch call for other communication.
ends.
Verifying the user Do not turn the power OFF • User authentication is being executed by the
registration until the one-touch call NC service side.
ends.
Connecting Do not turn the power OFF • The line is connected with one-touch call.
until the one-touch call
ends.
Receiving Do not turn the power OFF • The diagnosis data is being received with
until the one-touch call one-touch call.
ends.
Sending Do not turn the power OFF • The diagnosis data is being sent with one-touch
until the one-touch call call.
ends.
Transmission Press one-touch call to • Communication with one-touch call has ended,
completed call the NC service. and the line has been disconnected.
Do not turn the power OFF
during the one-touch call.
Reception completed Press one-touch call to • Communication with one-touch call has ended,
call the NC service. and the line has been disconnected.
• This is displayed when at least one file has
Do not turn the power OFF
been received.
during the one-touch call.
(Status of Connecting with NC • In connection standby state since line is being
communication with service. used by Anshin-net.
NC service) Wait for communication to
end.
IV - 101
Appendix 6. Alarms
6.2 Operation Messages
IV - 102
Appendix 6. Alarms
6.2 Operation Messages
IV - 103
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Network service is connected • The settings of the MTB net parameter 1,2 cannot be changed
since the system is communicating with Call Center or machine
tool builder. Set again after the communication has ended.
transmission ends.
Verifying the user Don't turn OFF a power • The system is waiting for an authentication
registration supply until diagnosis data response from remote diagnosis tool kit.
transmission ends.
Waiting for the reply Don't turn OFF a power • The line has been disconnected once, and
supply until diagnosis data the system is waiting for a connection with
the machine tool builder.
transmission ends.
Verifying the Don't turn OFF a power • The line has been connected corresponding
destination supply until diagnosis data to the received call from the machine tool
builder. The system is confirming the
transmission ends. destination of connection.
Connecting Don't turn OFF a power • The system is connected or connecting with
supply until diagnosis data machine tool builder.
transmission ends.
Transmitting Don't turn OFF a power • The diagnosis data is actually being
supply until diagnosis data transmitted.
transmission ends.
Transmission Press Y (transmit the • The transmission of diagnosis data has
completed diagnosis data) or N (cancel). ended, and the line has been disconnected.
You'll connect with MTB
when it gets available if line
used.
IV - 104
Appendix 6. Alarms
6.2 Operation Messages
Message Details
Waiting for dialing Don't turn OFF a power • The machine tool builder is using the line for
supply until diagnosis data other communication.
transmission ends.
(Status of Connecting with NC service. • In connection standby state since line is being
communication with Please wait until the used by Anshin-net.
NC service) communication ends.
(Status of Connecting with MTB. • In connection standby state since line is being
communication with Please wait until the used by the machine tool builder.
machine communication ends.
manufacturer)
IV - 105
Appendix 6. Alarms
6.2 Operation Messages
Can't command manual value • The manual numerical value protect is valid and therefore it is not
possible to perform a manual numerical value command.
Getting T code list • T code list is being retrieved.
T code list complete • Retrieving T code list is completed.
Load meter display not possible • The load meter cannot be displayed.
Contact the machine tool builder.
Pallet running • Each setting was executed during pallet running.
APC executing • Each setting was executed during automatic pallet changer
executing.
IV - 106
Appendix 6. Alarms
6.3 Program Error
IV - 107
Appendix 6. Alarms
6.3 Program Error
IV - 108
Appendix 6. Alarms
6.3 Program Error
IV - 109
Appendix 6. Alarms
6.3 Program Error
IV - 110
Appendix 6. Alarms
6.3 Program Error
IV - 111
Appendix 6. Alarms
6.3 Program Error
IV - 112
Appendix 6. Alarms
6.3 Program Error
IV - 113
Appendix 6. Alarms
6.3 Program Error
IV - 114
Appendix 6. Alarms
6.3 Program Error
IV - 115
Appendix 6. Alarms
6.3 Program Error
IV - 116
Appendix 6. Alarms
6.3 Program Error
IV - 117
Appendix 6. Alarms
6.3 Program Error
IV - 118
Appendix 6. Alarms
6.3 Program Error
IV - 119
Appendix 6. Alarms
6.3 Program Error
IV - 120
Appendix 6. Alarms
6.3 Program Error
IV - 121
Appendix 6. Alarms
6.3 Program Error
IV - 122
Appendix 6. Alarms
6.3 Program Error
IV - 123
Appendix 6. Alarms
6.3 Program Error
IV - 124
Appendix 6. Alarms
6.3 Program Error
IV - 125
Appendix 7. G Code Guidance Display List
IV - 126
Appendix 7. G Code Guidance Display List
O: Modal, ×: Unmodal
G code Group Function Modal
27 00 Reference point check ×
28 00 Reference point return ×
29 00 Start point return ×
30 00 2nd to 4th reference point return ×
30.1 00 Tool change position return 1 ×
30.2 00 Tool change position return 2 ×
30.3 00 Tool change position return 3 ×
30.4 00 Tool change position return 4 ×
30.5 00 Tool change position return 5 ×
30.6 00 Tool change position return 6 ×
31 00 Skip/Multi-step skip function 2 ×
31.1 00 Multi-step skip function 1-1 ×
31.2 00 Multi-step skip function 1-2 ×
31.3 00 Multi-step skip function 1-3 ×
32 - - -
33 01 Thread cutting O
34 00 Special fixed cycle (bolt hole circle) ×
35 00 Special fixed cycle (line at angle) ×
36 00 Special fixed cycle (arc) ×
37 00 Automatic tool length measurement ×
37.1 00 Special fixed cycle (grid) ×
38 00 Tool radius compensation vector designation ×
39 00 Tool radius compensation corner arc ×
40 07 Tool radius compensation cancel -
41 07 Tool radius compensation left O
42 07 Tool radius compensation right O
40.1 15 Normal line control cancel -
41.1 15 Normal line control left ON O
42.1 15 Normal line control right ON O
43 08 Tool length compensation (+) O
44 08 Tool length compensation (-) O
43.1 08 Tool length compensation along the tool axis O
43.4 08 Tool center point control type 1 O
43.5 08 Tool center point control type 2 O
45 00 Tool position compensation (expansion) ×
46 00 Tool position compensation (reduction) ×
47 00 Tool position compensation (doubled) ×
48 00 Tool position compensation (halved) ×
Tool length compensation cancel/Tool center point
49 08 -
control cancel
50 11 Scaling cancel -
51 11 Scaling ON O
50.1 19 G command mirror image cancel -
51.1 19 G command mirror image ON O
52 00 Local coordinate system setting O
53 00 Machine coordinate system selection ×
54 12 Work coordinate system 1 selection O
55 12 Work coordinate system 2 selection O
56 12 Work coordinate system 3 selection O
57 12 Work coordinate system 4 selection O
58 12 Work coordinate system 5 selection O
59 12 Work coordinate system 6 selection O
Work coordinate system selection 48 sets
54.1 12 O
expanded
IV - 127
Appendix 7. G Code Guidance Display List
O: Modal, ×: Unmodal
G code Group Function Modal
60 00 Uni-directional positioning ×
61 13 Exact stop check mode O
61.1 13 High-accuracy control O
61.2 13 High-accuracy spline O
62 13 Automatic corner override O
63 13 Tapping mode O
63.1 13 Synchronous tapping mode (normal tapping) O
63.2 13 Synchronous tapping mode (reverse tapping) O
64 13 Cutting mode O
65 00 User macro call ×
66 14 User macro modal call A O
66.1 14 User macro modal call B O
67 14 User macro modal call cancel -
Programmable coordinate rotation mode ON
68 16 O
/3-dimensional coordinate conversion mode ON
Programmable coordinate rotation mode OFF
69 16 -
/3-dimensional coordinate conversion mode OFF
70 09 User fixed cycle -
71 09 User fixed cycle -
72 09 User fixed cycle -
73 09 Fixed cycle (step) O
74 09 Fixed cycle (reverse tap) O
75 09 Fixed cycle (circle cutting cycle) O
76 09 Fixed cycle (fine boring) O
77 09 User fixed cycle -
78 09 User fixed cycle -
79 09 User fixed cycle -
80 09 Fixed cycle cancel -
81 09 Fixed cycle (drill/spot drill) O
82 09 Fixed cycle (drill/counter boring) O
83 09 Fixed cycle (deep drilling) O
84 09 Fixed cycle (tapping) O
85 09 Fixed cycle (boring) O
86 09 Fixed cycle (boring) O
87 09 Fixed cycle (back boring) O
88 09 Fixed cycle (boring) O
89 09 Fixed cycle (boring) O
90 03 Absolute value command O
91 03 Incremental command value O
92 00 Machine coordinate system setting O
93 05 Inverse time feed O
94 05 Asynchronous feed (per-minute feed) O
95 05 Synchronous feed (per-revolution feed) O
96 17 Constant surface speed control ON O
97 17 Constant surface speed control OFF -
98 10 Fixed cycle Initial level return O
99 10 Fixed cycle R point level return O
100 to 225 00 User macro (G code call) Max. 10 -
IV - 128
Revision History
Mar. 2005 IB(NA)1500042-B • Contents were revised to correspond to Mitsubishi CNC 700 Series software version
B0.
• The following sections were added to "I. SCREEN OPERATIONS":
1.1 Setting Display Unit Appearance
1.3 Screen Transition Diagram
1.4 Screen Selection Procedure
1.5 Setting Data
1.8 Guidance Function
2.2.2 Changing Whether to Show or Hide the Comment Field
2.3.5 Operation Sequence for Program Restart
2.5.8 Switching Full-screen Display Mode
2.16.2 Setting the Time Display Selection
2.22 Load Meter Display
2.23 Spindle, Standby Display
3.4.4 Erasing the Tool Registration Data
3.12 T Code List
4.2.17 G Code Guidance
4.3.8 Switching to Full-screen Display Mode
4.4.8 Switching to Full-screen Display Mode
5.7 Self Diagnosis Screen
5.8 Data Sampling Screen
6.3 All Backup Screen
6.4 System Setup Screen
6.5 Adjust S-analog Screen
6.6 Absolute Position Setting Screen
6.7 Auxiliary Axis Test Screen
6.8 Diagnosis Data Collection Setting Screen
• The following section names were changed:
"2.3.3 Directory change screen" -> "2.3.3 File Setting Screen"
"5.1 Hardware and software configuration screen (H/W S/W config screen)"
-> "5.1 System Configuration Screen "
• The following sections were unified.
"4.5.9 Formatting an FLD" and "4.5.10 Formatting a Memory card and DS"
-> "4.5.9 Formatting an External Device "
"6.2.9 Formatting an FLD" and "6.2.10 Formatting a Memory card and DS"
-> "6.2.9 Formatting an External Device "
• The configuration of "1. Operating the Setting and Display Unit" in "I. SCREEN
OPERATIONS" was changed.
• The following sections were added to " II. MACHINE OPERATIONS":
7. Stored Stroke Limit
• "III. MAINTENANCE" was added.
• The following sections were added to " IV. APPENDIXES":
6.2.15 System setup-related operation messages
6.2.16 Automatic backup-related operation messages
Appendix 7. G Code Guidance Display List
• Mistakes were corrected.
Date of revision Manual No. Revision details
Sept. 2005 IB(NA)1500042-C • Contents were revised to correspond to Mitsubishi CNC 700 Series software version
B3.
• The following sections were added to "I. SCREEN OPERATIONS":
1.8.2 Alarm Guidance
1.9 Touch Panel Functions
1.10 Touch Panel S/W Key
2.2.3 Changing the Sorting Method
3.3.1 Tool Measurement (M system)
3.3.2 Tool Measurement (L system)
3.7.4 Carrying Out Rotation Measurement
3.13 Pallet Program Registration
5.9 Anshin-net Screen
• The following section was added to " IV. APPENDIXES":
6.2.17 Messages Related to Anshin-net
• The following sections were changed to paragraph header:
3.3.1 Carrying Out Tool Length Measurement
3.3.2 Carrying Out Tool Radius Measurement
• The following sections were deleted:
6.1.2 Selecting the Parameter No.
6.1.6 Machine Parameters
• Mistakes were corrected.
Mar. 2006 IB(NA)1500042-D • Contents were revised to correspond to Mitsubishi CNC 700 Series software version
C0.
• The following sections were added to "I. SCREEN OPERATIONS":
4.2.17 Adding Sequence No. (N No.) Automatically
4.2.19 Playback Editing
4.5.12 Program Display Lock C
5.6.1 Alarm History
• Mistakes were corrected.
Sept. 2006 IB(NA)1500042-E • Contents were revised to correspond to Mitsubishi CNC 700 Series software version
D0.
• The following sections were added to "I. SCREEN OPERATIONS":
1.5.2 Inputting Operations
1.11 Screen Saver (Backlight OFF) Function
2.25 All Spindles' Rotation Speed Display
3.7.2 Workpiece Measurement (L System)
4.5.14 Sharing Machining Data
5.9.4 Sharing Machining Data
5.10 Machine Tool Builder Network System (MTB net) Screen
6.2.13 Sharing Machining Data
• The configuration of "3.2 Tool Measurement" was changed.
• The configuration of "3.7 Workpiece Measurement" was changed because
workpiece measurement (L system) is added.
• Mistakes were corrected.
Global service network
NORTH AMERICA FA Center CHINA FA Center
EUROPEAN FA Center KOREAN FA Center
ASEAN FA Center
TAIWAN FA Center
North America FA Center (MITSUBISHI ELECTRIC AUTOMATION INC.) ASEAN FA Center (MITSUBISHI ELECTRIC ASIA PTE. LTD.)
Illinois CNC Service Center Singapore CNC Service Center
500 CORPORATE WOODS PARKWAY, VERNON HILLS, IL. 60061, U.S.A. 307 ALEXANDRA ROAD #05-01/02 MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943
TEL: +1-847-478-2500 (Se FAX: +1-847-478-2650 (Se TEL: +65-6473-2308 FAX: +65-6476-7439
California CNC Service Center Thailand MITSUBISHI CNC Agent Service Center (F. A. TECH CO., LTD)
5665 PLAZA DRIVE, CYPRESS, CA. 90630, U.S.A. 898/19,20,21,22 S.V. CITY BUILDING OFFICE TOWER 1 FLOOR 12,14 RAMA III RD
TEL: +1-714-220-4796 FAX: +1-714-229-3818 BANGPONGPANG, YANNAWA, BANGKOK 10120. THAILAND
Georgia CNC Service Center TEL: +66-2-682-6522 FAX: +66-2-682-6020
2810 PREMIERE PARKWAY SUITE 400, DULUTH, GA., 30097, U.S.A. Malaysia MITSUBISHI CNC Agent Service Center
TEL: +1-678-258-4500 FAX:+1-678-258-4519 (FLEXIBLE AUTOMATION SYSTEM SDN. BHD.)
New Jersey CNC Service Center 60, JALAN USJ 10/1B 47620 UEP SUBANG JAYA SELANGOR DARUL EHSAN MALAYSIA
200 COTTONTAIL LANE SOMERSET, NJ. 08873, U.S.A. TEL: +60-3-5631-7605 FAX:+60-3-5631-7636
TEL: +1-732-560-4500 FAX: +1-732-560-4531 JOHOR MITSUBISHI CNC Agent Service Satellite
Michigan CNC Service Satellite (FLEXIBLE AUTOMATION SYSTEM SDN. BHD.)
2545 38TH STREET, ALLEGAN, MI., 49010, U.S.A. NO. 16, JALAN SHAHBANDAR 1, TAMAN UNGKU TUN AMINAH, 81300 SKUDAI, JOHOR MALAYSIA
TEL: +1-847-478-2500 FAX:+1-269-673-4092 TEL: +60-7-557-8218 FAX: +60-7-557-3404
Ohio CNC Service Satellite Indonesia MITSUBISHI CNC Agent Service Center
62 W. 500 S., ANDERSON, IN., 46013, U.S.A. (PT. AUTOTEKNINDO SUMBER MAKMUR)
TEL: +1-847-478-2608 FAX: +1-847-478-2690 WISMA NUSANTARA 14TH FLOOR JL. M.H. THAMRIN 59, JAKARTA 10350 INDONESIA
Texas CNC Service Satellite TEL: +62-21-3917-144 FAX: +62-21-3917-164
1000, NOLEN DRIVE SUITE 200, GRAPEVINE, TX. 76051, U.S.A. India MITSUBISHI CNC Agent Service Center (MESSUNG SALES & SERVICES PVT. LTD.)
TEL: +1-817-251-7468 FAX: +1-817-416-1439 B-36FF, PAVANA INDUSTRIAL PREMISES M.I.D.C., BHOASRI PUNE 411026, INDIA
Canada CNC Service Center TEL: +91-20-2711-9484 FAX: +91-20-2712-8115
4299 14TH AVENUE MARKHAM, ON. L3R OJ2, CANADA BANGALORE MITSUBISHI CNC Agent Service Satellite
TEL: +1-905-475-7728 FAX: +1-905-475-7935 (MESSUNG SALES & SERVICES PVT. LTD.)
Mexico CNC Service Center S 615, 6TH FLOOR, MANIPAL CENTER, BANGALORE 560001, INDIA
MARIANO ESCOBEDO 69 TLALNEPANTLA, 54030 EDO. DE MEXICO TEL: +91-80-509-2119 FAX: +91-80-532-0480
TEL: +52-55-9171-7662 FAX: +52-55-9171-7698 Delhi MITSUBISHI CNC Agent Parts Center (MESSUNG SALES & SERVICES PVT. LTD.)
Monterrey CNC Service Satellite 1197, SECTOR 15 PART-2, OFF DELHI-JAIPUR HIGHWAY BEHIND 32ND MILESTONE
ARGENTINA 3900, FRACC. LAS TORRES, MONTERREY, N.L., 64720, MEXICO GURGAON 122001, INDIA
TEL: +52-81-8365-4171 FAX: +52-81-8365-4171 TEL: +91-98-1024-8895 FAX:
Brazil MITSUBISHI CNC Agent Service Center Philippines MITSUBISHI CNC Agent Service Center
(AUTOMOTION IND. COM. IMP. E EXP. LTDA.) (FLEXIBLE AUTOMATION SYSTEM CORPORATION)
ACESSO JOSE SARTORELLI, KM 2.1 18550-000 BOITUVA – SP, BRAZIL UNIT No.411, ALABAMG CORPORATE CENTER KM 25. WEST SERVICE ROAD SOUTH
TEL: +55-15-3363-9900 FAX: +55-15-3363-9911 SUPERHIGHWAY, ALABAMG MUNTINLUPA METRO MANILA, PHILIPPINES 1771
TEL: +63-2-807-2416 FAX: +63-2-807-2417
European FA Center (MITSUBISHI ELECTRIC EUROPE B.V.) Vietnam MITSUBISHI CNC Agent Service Center (SA GIANG TECHNO CO., LTD)
47-49 HOANG SA ST. DAKAO WARD, DIST.1 HO CHI MINH CITY, VIETNAM
Germany CNC Service Center TEL: +84-8-910-4763 FAX:+84-8-910-2593
GOTHAER STRASSE 8, 40880 RATINGEN, GERMANY
TEL: +49-2102-486-0 FAX:+49-2102486-591
South Germany CNC Service Center China FA Center (MITSUBISHI ELECTRIC AUTOMATION (SHANGHAI) LTD.)
KURZE STRASSE. 40, 70794 FILDERSTADT-BONLANDEN, GERMANY China CNC Service Center
TEL: +49-711-3270-010 FAX: +49-711-3270-0141 2/F., BLOCK 5 BLDG.AUTOMATION INSTRUMENTATION PLAZA, 103 CAOBAO RD. SHANGHAI
France CNC Service Center 200233, CHINA
25, BOULEVARD DES BOUVETS, 92741 NANTERRE CEDEX FRANCE TEL: +86-21-6120-0808 FAX: +86-21-6494-0178
TEL: +33-1-41-02-83-13 FAX: +33-1-49-01-07-25 Shenyang CNC Service Center
Lyon CNC Service Satellite TEL: +86-24-2397-0184 FAX: +86-24-2397-0185
Beijing CNC Service Satellite
U.K CNC Service Center 9/F, OFFICE TOWER1, HENDERSON CENTER, 18 JIANGUOMENNEI DAJIE, DONGCHENG
TRAVELLERS LANE, HATFIELD, HERTFORDSHIRE, AL10 8XB, U.K. DISTRICT, BEIJING 100005, CHINA
TEL: +44-1707-282-846 FAX:-44-1707-278-992 TEL: +86-10-6518-8830 FAX:+86-10-6518-8030
Italy CNC Service Center China MITSUBISHI CNC Agent Service Center
ZONA INDUSTRIALE VIA ARCHIMEDE 35 20041 AGRATE BRIANZA, MILANO ITALY (BEIJING JIAYOU HIGHTECH TECHNOLOGY DEVELOPMENT CO.)
TEL: +39-039-60531-342 FAX: +39-039-6053-206 RM 709, HIGH TECHNOLOGY BUILDING NO.229 NORTH SI HUAN ZHONG ROAD, HAIDIAN
Spain CNC Service Satellite DISTRICT , BEIJING 100083, CHINA
CTRA. DE RUBI, 76-80 -APDO.420 08190 SAINT CUGAT DEL VALLES, BARCELONA SPAIN TEL: +86-10-8288-3030 FAX:+86-10-6518-8030
TEL: +34-935-65-2236 FAX: Tianjin CNC Service Satellite
Turkey MITSUBISHI CNC Agent Service Center RM909, TAIHONG TOWER, NO220 SHIZILIN STREET, HEBEI DISTRICT, TIANJIN, CHINA 300143
(GENEL TEKNIK SISTEMLER LTD. STI.) TEL: -86-22-2653-9090 FAX: +86-22-2635-9050
DARULACEZE CAD. FAMAS IS MERKEZI A BLOCK NO.43 KAT2 80270 OKMEYDANI Shenzhen CNC Service Satellite
ISTANBUL, TURKEY RM02, UNIT A, 13/F, TIANAN NATIONAL TOWER, RENMING SOUTH ROAD, SHENZHEN, CHINA
TEL: +90-212-320-1640 FAX: +90-212-320-1649 518005
Poland MITSUBISHI CNC Agent Service Center (MPL Technology Sp. z. o. o) TEL: +86-755-2515-6691 FAX:+86-755-8218-4776
UL SLICZNA 34, 31-444 KRAKOW, POLAND Changchun Service Satellite
TEL: +48-12-632-28-85 FAX: TEL: +86-431-50214546 FAX: +86-431-5021690
Wroclaw MITSUBISHI CNC Agent Service Satellite (MPL Technology Sp. z. o. o) Hong Kong CNC Service Center
UL KOBIERZYCKA 23, 52-315 WROCLAW, POLAND UNIT A, 25/F RYODEN INDUSTRIAL CENTRE, 26-38 TA CHUEN PING STREET, KWAI CHUNG, NEW
TEL: +48-71-333-77-53 FAX:+48-71-333-77-53 TERRITORIES, HONG KONG
Czech MITSUBISHI CNC Agent Service Center TEL: +852-2619-8588 FAX:+852-2784-1323
(AUTOCONT CONTROL SYSTEM S.R.O. )
NEMOCNICNI 12, 702 00 OSTRAVA 2 CZECH REPUBLIC Taiwan FA Center (MITSUBISHI ELECTRIC TAIWAN CO., LTD.)
TEL: +420-596-152-426 FAX: +420-596-152-112 Taichung CNC Service Center
NO.8-1, GONG YEH 16TH RD., TAICHUNG INDUSTIAL PARK TAICHUNG CITY, TAIWAN R.O.C.
TEL: +886-4-2359-0688 FAX:+886-4-2359-0689
Taipei CNC Service Satellite
TEL: +886-4-2359-0688 FAX:+886-4-2359-0689
Tainan CNC Service Satellite
TEL: +886-4-2359-0688 FAX: +886-4-2359-0689
Duplication Prohibited
This manual may not be reproduced in any form, in part or in whole, without written
permission from Mitsubishi Electric Corporation.
© 2004-2006 MITSUBISHI ELECTRIC CORPORATION
ALL RIGHTS RESERVED.