1 Anchor Design
1.1 Input data
Anchor plate
CBFEM
: lx x ly x t = 320.0 mm x 320.0 mm x 10.0 mm;
CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
Tension
Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)
Variables
2 2
Ase,N [mm ] futa [N/mm ]
38 860.00
Calculations
Nsa [kN]
32.500
Results
Nsa [kN] f steel f Nsa [kN] Nua [kN]
32.500 0.750 24.375 6.160
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
Ncbg = (AA ) y
Nc
Nc0
ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b)
f Ncbg ³ Nua ACI 318-19 Table 17.5.2
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
2
ANc0 = 9 hef ACI 318-19 Eq. (17.6.2.1.4)
( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-19 Eq. (17.6.2.3.1)
1+
3 hef
ef
ACI 318-19 Eq. (17.6.2.4.1b)
= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-19 Eq. (17.6.2.6.1b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-19 Eq. (17.6.2.2.1)
Variables
hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm] y c,N
60.0 0.2 0.3 ∞ 1.000
'
cac [mm] kc la fc [psi]
115.0 17 1.000 5,802
Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
129,600 32,400 0.998 0.997 1.000 1.000 20.911
Results
Ncbg [kN] f concrete f Ncbg [kN] Nua [kN]
83.223 0.650 54.095 24.550
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
Variables
2 2
Ase,V [mm ] futa [N/mm ]
38 860.00
Calculations
Vsa [kN]
19.100
Results
Vsa [kN] f steel f Vsa [kN] Vua [kN]
19.100 0.650 12.415 1.638
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
Nc0
ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b)
f Vcpg ³ Vua ACI 318-19 Table 17.5.2
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
2
ANc0 = 9 hef ACI 318-19 Eq. (17.6.2.1.4)
( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-19 Eq. (17.6.2.3.1)
1+
3 hef
ef
ACI 318-19 Eq. (17.6.2.4.1b)
= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-19 Eq. (17.6.2.6.1b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-19 Eq. (17.6.2.2.1)
Variables
kcp hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm]
1 60.0 0.0 0.0 ∞
'
y c,N cac [mm] kc la fc [psi]
1.000 115.0 17 1.000 5,802
Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
129,600 32,400 1.000 1.000 1.000 1.000 20.911
Results
Vcpg [kN] f concrete f Vcpg [kN] Vua [kN]
83.645 0.700 58.552 6.403
1.5 Combined tension and shear loads, per ACI 318-19 section 17.8
z z
bNV = bN + bV <= 1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA
TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor
plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.
The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the
potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or
where pullout or pryout strength governs.
• Refer to the manufacturer's product literature for cleaning and installation instructions.
• For additional information about ACI 318 strength design provisions, please go to
https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
• Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference
ACI 318-19, Section 26.7.
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
Hilti HST3 stud anchor with 68 mm embedment, M10 hef2, Carbon steel, installation per ER-578
y
160.0 160.0
35.0
3 4
160.0
250.0
x
160.0
1 2
35.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
2.2 Summary
Description Profile Anchor plate Welds [%] Concrete [%]
sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] Hole bearing
[%]
1 Combination 1 43.34 0.00 76.59 0.00 3 18 4
2.3 Anchor plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid anchor plate (CBFEM) Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 3.991 kN 6.115 kN
Anchor 2 3.999 kN 6.134 kN
Anchor 3 4.001 kN 6.141 kN
Anchor 4 4.009 kN 6.160 kN
User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can
be applied.
2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for
critical cross sections, which should be performed outside of PROFIS Engineering.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
275.00 N/mm²
0.00 N/mm²
2.4.1.2 Plastic strain
Results below are displayed for the decisive load combination: 1 - Combination 1
5.00%
0.00%
2.4.2 Plate hole bearing resistance, AISC 360-16 Section J3
Decisive load combination: 1 - Combination 1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
Equations
FRn = 0.75 Rn
V ≤ FRn
Variables
lc [mm] t [mm] Fu [N/mm²] d [mm] Rn [kN]
Anchor 1 38.9 10.0 430.00 10.0 103.200
Anchor 2 38.1 10.0 430.00 10.0 103.200
Anchor 3 48.5 10.0 430.00 10.0 103.200
Anchor 4 358.4 10.0 430.00 10.0 103.200
Results
V [kN] FRn [kN] Utilization [%] Status
Anchor 1 1.639 77.400 3 OK
Anchor 2 1.604 77.400 3 OK
Anchor 3 1.594 77.400 3 OK
Anchor 4 1.568 77.400 3 OK
2.5 Welds
Profiles are modeled without taking the corner radius into account. Special rules for welding (e.g. for cold-formed profiles ...) are not taken into
account by the software.
Equations
FRn = F Fnw Aw
Fn
Utilization =
F Rn
Variables
Edge Xu Th [mm] Ls [mm] L [mm] Lc [mm] FEXX [N/mm²] Q [°] Aw [mm²]
Member 1-tfl 1 E70xx 5.0 7.1 199.5 20.0 482.63 45.2 100
Member 1-bfl 1 E70xx 5.0 7.1 199.5 20.0 482.63 44.8 100
Results
Edge Fn [kN] FRn [kN] Utilization [%] Status
Member 1-tfl 1 4.547 28.144 17 OK
Member 1-bfl 1 4.903 28.072 18 OK
2.6 Concrete
Decisive load combination: 1 - Combination 1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
0.00 N/mm²
2.6.2 Concrete block compressive strength resistance check, AISC 360-16 Section J8
Equations
Fp = F fp,max
A A
2 2
fp,max = 0.85 fc' √( ) ≤ 1.7 fc; √( )≤2
A A
1 1
N
s = A
1
Utilization =
s
Fp
Variables
N [kN] fc' [N/mm²] F A1 [mm²] A2 [mm²]
8.969 40.00 0.65 6,593 1,570,827
Results
Load combination Fp [N/mm²] s [N/mm²] Utilization [%] Status
Combination 1 44.20 1.36 4 OK
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
2.8 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability
and adequacy for your specific jurisdiction and project requirements.
● The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
13
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
3 Summary of results
Design of the anchor plate, anchors, welds and other elements are based on CBFEM (component based finite element method) and AISC.
Load combination Max. utilization Status
Anchors Combination 1 46% OK
Anchor plate Combination 1 28% OK
Welds Combination 1 18% OK
Concrete Combination 1 4% OK
Profile Combination 1 16% OK
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
14
Hilti PROFIS Engineering 3.0.92
www.hilti.com.qa
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19/3/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
15