Hilti PROFIS Engineering 3.0.

92

www.hilti.com.qa
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

Specifier's comments:

1 Anchor Design
1.1 Input data

Anchor type and diameter: HST3 M10 hef2


Item number: 2105712 HST3 M10x90 30/10
Effective embedment depth: hef,act = 60.0 mm, hnom = 68.0 mm
Material:
Evaluation Service Report: ER-578
Issued I Valid: 13‫‏‏‬/3‫‏‏‬/2023 | 28‫‏‏‬/2‫‏‏‬/2024
Proof: Design Method ACI 318-19 / Mech
Stand-off installation: eb = 0.0 mm (no stand-off); t = 10.0 mm

Anchor plate
CBFEM
: lx x ly x t = 320.0 mm x 320.0 mm x 10.0 mm;

Profile: Square hollow, 200 x 200 x 5; (L x W x T) = 200.0 mm x 200.0 mm x 5.0 mm


Base material: cracked concrete, C40/50, fc' = 5,802 psi; h = 250.0 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar

CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

1.1.1 Design results


Case Description Forces [kN] / Moments [kNm] Seismic Max. Util. Anchor [%]
1 Combination 1 N = 16.000; Vx = 4.000; Vy = 5.000; no 46
Mx = 0.000; My = 0.000; Mz = 0.000;

1.2 Load case/Resulting anchor forces y


3 4

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 6.115 1.638 1.026 1.278
2 6.134 1.604 0.974 1.274 x
3 6.141 1.594 1.024 1.222
4 6.160 1.568 0.977 1.226

resulting tension force in (x/y)=(0.2/0.3): 24.550 [kN]


1 2
resulting compression force in (x/y)=(0.0/0.0): 0.000 [kN]

Tension
Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)

1.3 Tension load

Load Nua [kN] Capacity f Nn [kN] Utilization bN = Nua/f Nn Status


Steel Strength* 6.160 24.375 26 OK
Pullout Strength* N/A N/A N/A N/A
Concrete Breakout Failure** 24.550 54.095 46 OK

* highest loaded anchor **anchor group (anchors in tension)

1.3.1 Steel Strength

Nsa = ESR value refer to ICC-ES ER-578


f Nsa ³ Nua ACI 318-19 Table 17.5.2

Variables
2 2
Ase,N [mm ] futa [N/mm ]
38 860.00

Calculations
Nsa [kN]
32.500

Results
Nsa [kN] f steel f Nsa [kN] Nua [kN]
32.500 0.750 24.375 6.160

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

1.3.2 Concrete Breakout Failure

Ncbg = (AA ) y
Nc

Nc0
ec,N y ed,N y c,N y cp,N Nb ACI 318-19 Eq. (17.6.2.1b)
f Ncbg ³ Nua ACI 318-19 Table 17.5.2
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
2
ANc0 = 9 hef ACI 318-19 Eq. (17.6.2.1.4)

( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-19 Eq. (17.6.2.3.1)
1+
3 hef

y ed,N = 0.7 + 0.3 (1.5h


c
) £ 1.0 a,min

ef
ACI 318-19 Eq. (17.6.2.4.1b)

= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-19 Eq. (17.6.2.6.1b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-19 Eq. (17.6.2.2.1)

Variables
hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm] y c,N
60.0 0.2 0.3 ∞ 1.000

'
cac [mm] kc la fc [psi]
115.0 17 1.000 5,802

Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
129,600 32,400 0.998 0.997 1.000 1.000 20.911

Results
Ncbg [kN] f concrete f Ncbg [kN] Nua [kN]
83.223 0.650 54.095 24.550

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

1.4 Shear load

Load Vua [kN] Capacity f Vn [kN] Utilization bV = Vua/f Vn Status


Steel Strength* 1.638 12.415 14 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 6.403 58.552 11 OK
Concrete edge failure in direction ** N/A N/A N/A N/A

* highest loaded anchor **anchor group (relevant anchors)

1.4.1 Steel Strength

Vsa = ESR value refer to ICC-ES ER-578


f Vsteel ³ Vua ACI 318-19 Table 17.5.2

Variables
2 2
Ase,V [mm ] futa [N/mm ]
38 860.00

Calculations
Vsa [kN]
19.100

Results
Vsa [kN] f steel f Vsa [kN] Vua [kN]
19.100 0.650 12.415 1.638

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

1.4.2 Pryout Strength

Vcpg = kcp [(AA ) y Nc

Nc0
ec,N y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1b)
f Vcpg ³ Vua ACI 318-19 Table 17.5.2
ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b)
2
ANc0 = 9 hef ACI 318-19 Eq. (17.6.2.1.4)

( )
1
'
y ec,N = 2 eN £ 1.0 ACI 318-19 Eq. (17.6.2.3.1)
1+
3 hef

y ed,N = 0.7 + 0.3 (1.5h


c
) £ 1.0 a,min

ef
ACI 318-19 Eq. (17.6.2.4.1b)

= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 ACI 318-19 Eq. (17.6.2.6.1b)
c ac ac
1.5
Nb = kc l a √ '
fc hef ACI 318-19 Eq. (17.6.2.2.1)

Variables
kcp hef [mm] ec1,N [mm] ec2,N [mm] ca,min [mm]
1 60.0 0.0 0.0 ∞

'
y c,N cac [mm] kc la fc [psi]
1.000 115.0 17 1.000 5,802

Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N Nb [kN]
129,600 32,400 1.000 1.000 1.000 1.000 20.911

Results
Vcpg [kN] f concrete f Vcpg [kN] Vua [kN]
83.645 0.700 58.552 6.403

1.5 Combined tension and shear loads, per ACI 318-19 section 17.8

bN bV z Utilization bN,V [%] Status


0.454 0.132 5/3 31 OK

z z
bNV = bN + bV <= 1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA
TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor
plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.
The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the
potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or
where pullout or pryout strength governs.
• Refer to the manufacturer's product literature for cleaning and installation instructions.
• For additional information about ACI 318 strength design provisions, please go to
https://submittals.us.hilti.com/PROFISAnchorDesignGuide/
• Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference
ACI 318-19, Section 26.7.
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

1.7 Installation data

Anchor type and diameter: HST3 M10 hef2


Profile: Square hollow, 200 x 200 x 5; (L x W x T) = 200.0 mm x 200.0 mm x Item number: 2105712 HST3 M10x90 30/10
5.0 mm
Hole diameter in the fixture: df = 12.0 mm Maximum installation torque: 45 Nm
Plate thickness (input): 10.0 mm Hole diameter in the base material: 10.0 mm
Hole depth in the base material: 73.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 120.0 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.

Hilti HST3 stud anchor with 68 mm embedment, M10 hef2, Carbon steel, installation per ER-578

1.7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Torque wrench
• Properly sized drill bit • Hammer

y
160.0 160.0
35.0

3 4
160.0
250.0

x
160.0

1 2
35.0

35.0 250.0 35.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -125.0 -125.0 - - - -
2 125.0 -125.0 - - - -
3 -125.0 125.0 - - - -
4 125.0 125.0 - - - -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

1.8 Drilling and installation

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

2 Anchor plate design

2.1 Input data


Anchor plate: Shape: Rectangular
lx x ly x t = 320.0 mm x 320.0 mm x 10.0 mm
Calculation: CBFEM
Material: S 275; Fy = 275.00 N/mm²; εlim = 5.00%
Anchor type and size: HST3 M10 hef2, hef = 60.0 mm
Anchor stiffness: The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method: AISC and LRFD-based design using component-based FEM
Stand-off installation: eb = 0.0 mm (No stand-off); t = 10.0 mm
Profile: 200 x 200 x 5; (L x W x T x FT) = 200.0 mm x 200.0 mm x 5.0 mm x -
Material: S 275; Fy = 275.00 N/mm²; εlim = 5.00%
Eccentricity x: 0.0 mm
Eccentricity y: 0.0 mm
Base material: Cracked concrete; C40/50; fc,cyl = 40.00 N/mm²; h = 250.0 mm
Welds (profile to anchor plate): Type of redistribution: Plastic
Material: E70xx
Mesh size: Number of elements on edge: 8
Min. size of element: 10.0 mm
Max. size of element: 50.0 mm

2.2 Summary
Description Profile Anchor plate Welds [%] Concrete [%]
sEd [N/mm²] ePl [%] sEd [N/mm²] ePl [%] Hole bearing
[%]
1 Combination 1 43.34 0.00 76.59 0.00 3 18 4
2.3 Anchor plate classification
Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid anchor plate (CBFEM) Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 3.991 kN 6.115 kN
Anchor 2 3.999 kN 6.134 kN
Anchor 3 4.001 kN 6.141 kN
Anchor 4 4.009 kN 6.160 kN

User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can
be applied.

2.4 Profile/Stiffeners/Plate
Profile and stiffeners are verified at the level of the steel to concrete connection. The connection design does not replace the steel design for
critical cross sections, which should be performed outside of PROFIS Engineering.

2.4.1 Equivalent stress and plastic strain


Part Load Material fy [N/mm²] elim [%] sEd [N/mm²] ePl [%] Status
combination
Plate Combination 1 S 275 275.00 5.00 76.59 0.00 OK
Profile Combination 1 S 275 275.00 5.00 27.63 0.00 OK
Profile Combination 1 S 275 275.00 5.00 30.32 0.00 OK
Profile Combination 1 S 275 275.00 5.00 39.70 0.00 OK
Profile Combination 1 S 275 275.00 5.00 43.34 0.00 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

2.4.1.1 Equivalent stress


Results below are displayed for the decisive load combination: 1 - Combination 1

275.00 N/mm²

0.00 N/mm²
2.4.1.2 Plastic strain
Results below are displayed for the decisive load combination: 1 - Combination 1

5.00%

0.00%
2.4.2 Plate hole bearing resistance, AISC 360-16 Section J3
Decisive load combination: 1 - Combination 1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

Equations

Rn = min(1.2 lc t Fu , 2.4 d t Fu) (AISC 360-16 J3-6a, c)

FRn = 0.75 Rn
V ≤ FRn
Variables
lc [mm] t [mm] Fu [N/mm²] d [mm] Rn [kN]
Anchor 1 38.9 10.0 430.00 10.0 103.200
Anchor 2 38.1 10.0 430.00 10.0 103.200
Anchor 3 48.5 10.0 430.00 10.0 103.200
Anchor 4 358.4 10.0 430.00 10.0 103.200

Results
V [kN] FRn [kN] Utilization [%] Status
Anchor 1 1.639 77.400 3 OK
Anchor 2 1.604 77.400 3 OK
Anchor 3 1.594 77.400 3 OK
Anchor 4 1.568 77.400 3 OK

2.5 Welds
Profiles are modeled without taking the corner radius into account. Special rules for welding (e.g. for cold-formed profiles ...) are not taken into
account by the software.

2.5.1 Anchor plate to profile


Decisive load combination: 1 - Combination 1

Equations

Fnw = 0.6 FEXX (1.0 + 0.5sin1.5 Q)

FRn = F Fnw Aw
Fn
Utilization =
F Rn
Variables
Edge Xu Th [mm] Ls [mm] L [mm] Lc [mm] FEXX [N/mm²] Q [°] Aw [mm²]
Member 1-tfl 1 E70xx 5.0 7.1 199.5 20.0 482.63 45.2 100
Member 1-bfl 1 E70xx 5.0 7.1 199.5 20.0 482.63 44.8 100

Results
Edge Fn [kN] FRn [kN] Utilization [%] Status
Member 1-tfl 1 4.547 28.144 17 OK
Member 1-bfl 1 4.903 28.072 18 OK

2.6 Concrete
Decisive load combination: 1 - Combination 1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

2.6.1 Compression in concrete under the anchor plate


2.97 N/mm²

0.00 N/mm²

2.6.2 Concrete block compressive strength resistance check, AISC 360-16 Section J8

Equations

Fp = F fp,max
A A
2 2
fp,max = 0.85 fc' √( ) ≤ 1.7 fc; √( )≤2
A A
1 1

N
s = A
1

Utilization =
s
Fp

Variables
N [kN] fc' [N/mm²] F A1 [mm²] A2 [mm²]
8.969 40.00 0.65 6,593 1,570,827

Results
Load combination Fp [N/mm²] s [N/mm²] Utilization [%] Status
Combination 1 44.20 1.36 4 OK

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

12
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

2.7 Symbol explanation


A1 Loaded area of concrete
A2 Supporting area
Aw Effective area of weld critical element
d Nominal diameter of the bolt
elim Limit plastic strain
ePl Plastic strain from CBFEM results
fc Concrete compressive strength
fc' Concrete compressive strength
FEXX Electrode classification number, i.e. minimum specified tensile strength
Fu Specified minimum tensile strength of the connected material
Fn Force in weld critical element
Fnw Nominal stress of the weld material
Fp Concrete block design bearing strength
fp,max Concrete block design bearing strength maximum
fy Yield strength
lc Clear distance, in the direction of the force, between the edge of the hole and the edge of the adjacent hole or
edge of the material
L Length of weld
Lc Length of weld critical element
Ls Leg size of weld
N Resulting compression force
s Average stress in concrete
sEd Equivalent stress
F Resistance factor
FRn Factored resistance
Rn Resistance
t Thickness of the anchor plate
Q Angle of loading measured from the weld longitudinal axis
Th Throat thickness of weld
V Resultant of shear forces Vy, Vz in bolt.
Xu Filler metal tensile strength

2.8 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability
and adequacy for your specific jurisdiction and project requirements.
● The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

13
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

3 Summary of results
Design of the anchor plate, anchors, welds and other elements are based on CBFEM (component based finite element method) and AISC.
Load combination Max. utilization Status
Anchors Combination 1 46% OK
Anchor plate Combination 1 28% OK
Welds Combination 1 18% OK
Concrete Combination 1 4% OK
Profile Combination 1 16% OK

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

14
Hilti PROFIS Engineering 3.0.92

www.hilti.com.qa
Company: Page: 15
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 11, 2024 Date: 19‫‏‏‬/3‫‏‏‬/2024
Fastening point:

4 Remarks; Your Cooperation Duties


● Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,
formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc.,
that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be
conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based
essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the
relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and
cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility.
The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and
the relevance of the results or suitability for a specific application.
● You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you
do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the
Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery
of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

15