The radio is part of the WinLink 1000 ODU-HE Series that supports native TDM and
Ethernet over a single wireless link. Providing capacity of 18 Mbps symmetric
throughput at distances of up to 80 km/50 miles, the radio transports up to 4
E1/T1s plus Ethernet traffic. Its high transmission power makes WinLink 1000 ODU-
HE radios the ideal solution to cover long distances and grant superior
robustness. The series supports Hub Site Synchronization enabling to operate up
to 16 collocated RADWIN radios.
WinLink 1000 ODU-HE radios can be operated with RADWIN IDU-C and IDU-E
Product Highlights Indoor devices as well as with the RADWIN PoE device for Ethernet only traffic.
• Native TDM WinLink 1000 ODU-HE is the ideal solution for service providers and corporations
(up to 4 E1s/T1s) and looking to profitably establish high-capacity networks over long distances.
Ethernet over a single
wireless link
• 18 Mbps symmetric Product Specifications
throughput
Configuration
• Operational range of up
Architecture Outdoor Unit with Integrated Antenna
to 80 km/50 miles
IDU to ODU Interface Outdoor CAT-5e cable; Maximum cable length: 100 m
• Configurable to support IDU-C RW-7200-2000 and RW-7204-2000; IDU-E Series (AT00629XX*);
Supported Indoor Units
5, 10 and 20 MHz PoE device (RW-9921-001X*)
Radio
channel bandwidth
Capacity 18 Mbps symmetric net throughput (up to 4 E1s/T1s plus Ethernet)
• High transmission power Frequency Bands 2.402 - 2.472 GHz
Range Up to 80 km/50 miles
• Extremely simple to install Channel Bandwidth Configurable: 5, 10, 20 MHz
and maintain Modulation OFDM – BPSK/QPSK/16QAM/64QAM
• OFDM technology Adaptive Modulation & Coding Supported
enabling nLOS Automatic Channel Selection Supported
Max Tx Power 27 dBm
deployments
Duplex Technology TDD
• Supporting Hub Site Error Correction FEC k = 1/2, 2/3, 3/4
Synchronization for Encryption AES 128
collocated units Hub Site Synchronization (HSS) Up to 16 collocated ODUs (RADWIN 2000 and/or WinLink 1000)
• Local and remote 1+1 with RADWIN 2000 link or WinLink 1000 link (must be operated
Monitored Hot Standby (MHS)
with IDU-C to support MHS)
network management
* For the exact X digit (ordering options), see RADWIN Product Catalog
Mechanical
Dimensions 30.5cm(H) x 30.5cm(W) x 5.8cm(D)
Weight 1.5kg/3.3lbs
Power and Mounting
Power Feeding Power provided by IDU or PoE
Power Consumption <10 W
Mounting Pole and Wall
Environmental
Enclosure All weather case
Operating Temperatures -35°C to + 60°C / -31°F to 140°F
100% condensing, IP67 (totally protected against dust and against
Humidity
immersion up to 1m)
ETSI IEC 60721-3-4 Class 4M5
Radio Regulations
FCC CFR47 : PART 15, subpart C
IC RSS-210
Safety
cTUVus UL 60950-1:2007; UL 60950-22:2007; CAN/CSA C22.2 No. 60950-1-07;
CAN/CSA C22.2.60950-22:2007
EN/IEC EN 60950-1:2006; EN 60950-22:2006; IEC 60950-1:2005; IEC 60950-22:2005
EMC
FCC 47 CFR Part 15:2007, Subpart B, Class B
CAN/CSA ICES-003:2004 Issue 4, Class B
ETSI EN 300 386 V1.3.3:2005; EN 301 489-4 V1.3.1:2002
DS AT0060300/01/02.10
Corporate Headquarters
T. +972.3.766.2917
E. sales@radwin.com