IDU-R Product Preview

(Beta Release: April 2007)

The WinLink™ 1000 IDU-R provides a


backup link for a leased line via a
redundant wireless link. In addition, the
IDU-R provides a carrier grade Ethernet
link that can be used for data services.

In most cases, the E1/T1 leased line is


defined as the primary link and the radio
link as backup. The IDU-R constantly
monitors the status of the leased line
and, in the event of a failure (detected
according LOS or AIS indications),
switches automatically to the radio link in
less than 25 milliseconds. Terrestrial Link Operational – WinLink 1000 in Standby Mode

The WinLink™ 1000 is maintained in


hot-standby mode as a fully operational,
synchronized link. The Ethernet capacity
of the WinLink™ 1000 is available at all
times, regardless of the status of the
leased line.

The IDU-R will be available with the


following ordering options:

• WL1000-IDUR-E1/ACEU
• WL1000-IDUR-T1/ACUS
Terrestrial Link Fails – WinLink 1000 switches to Active Mode

As with all IDUs in the WinLink™ 1000 Family, the WinLink™ 1000 IDU-R works
with all WinLink™ 1000 ODU products.

RADWIN Ltd. January 2007


IDU-R Technical Specifications
E1/T1 Interface
Framing Unframed (transparent)
Number of E1/T1 Interfaces 2 (1 for user network, 1 for thru leased line)
Connector RJ-45
Line Code E1: HD83 @ 2.048 Mbps; T1: B8SZ/AMI @ 1.544
Mbps
Standards Compliance ITU-T G.703, G.826
Jitter & Wander According to ITU-T G.823, G.824
Timing Independent Tx and Rx clocks
Latency Radio - 8 msec (typical)
Impedance E1: 120Ω, balanced; T1: 100Ω, balanced
LAN Interface
Type 10/100BaseT Interface with Auto-negotiation (IEEE
802.3)
Number of Ethernet Ports 2
Framing/Coding IEEE 802.3/U
Line Impedance 100Ω
Connector RJ-45
VLAN Support Transparent
Maximum Frame Length 1536 Bytes
Latency 3 msec (typical)
Management
Protocol SNMP based
Network Management SNMPc, HPOV
Dry Contact Alarms 4 Inputs + 4 Outputs (D-25 Type Connector);
Configurable by the Management application
Mechanics
Dimensions 16.5cm(L) x 23.5cm(W) x 4.5cm(H)
Weight 0.5 kg/1.1 lbs
Power and Mounting
Power Feeding 110/220VAC; 20 - 60VDC Dual
Power Consumption 3W (not including radio)
Environmental
Operating Temperatures -5°C - 45°C / 23°F - 113°F
Humidity 90% non-condensing
Safety
TUV 60950, According to UL 60950
CAN/CSA C22.2 No. 60950
EMC
FCC:CFR47 Class B, Part15, EN: 300 386 V1.3.2; 301 489-1 V1.4.1;
Subpart B 55022:1998; 61000-3-2:2000;
61000-3-3:1995; 55024:1998
CAN/CSA-CEI/IEC AS/NZS: CISPR 22, CISPR 22:2002, CISPR 22:1997

RADWIN Ltd. January 2007