AlcAtel-lucent

OmniSwitch 6855
HARDENED LAN SWITCH

Alcatel-Lucent OmniSwitch™ 6855 Hardened LAN Switch (HLS) models are industrial grade,
managed, Gigabit and 10 Gigabit Ethernet switches designed to operate reliably in harsh
electrical environments and severe temperatures.

This superior, rugged hardware design, The target applications for these versatile
coupled with the widely deployed and LAN switches are power utilities, trans-
field-proven Alcatel-Lucent Operating portation and traffic control systems,
System (AOS), makes the OmniSwitch 6855 industrial factory floor installations,
ideal for industrial and mission-critical video surveillance systems and outdoor
applications that require wider operating installations, all of which require gigabit
temperature ranges, more stringent EMC/ backbone connectivity.
EMI requirements and an optimized
feature set for high security, reliability,
performance and easy management.

FeAtuReS BeneFitS
Ruggedized hardware design Operates at a wider temperature range from -40°C to +75°C, with-
stands greater shock, vibrations, temperature and EMI/EMC tests
Convection cooling for fanless models or temperature triggered Increased reliability, and lower acoustic levels
fans for 24 port models
Power over Ethernet (PoE) support on all copper models Enables converged applications by providing power to IP phones,
surveillance cameras, and wireless access points
Redundancy at all levels including power supplies, software A field-upgradeable solution that makes the network highly available
and hot-swappable. Small Form Factor Pluggable (SFP) modules and reduces operating expenses
Wire-rate switching and routing at gigabit speeds. Advanced Outstanding performance when supporting real-time voice, data, and
services incorporated in the operating system (OS): quality of video applications for converged scalable networks
service (QoS), access control lists (ACLs), L2/L3, VLAN stacking,
and IPv6
Extensive security features for network access control (NAC), Fully secures the network at the edge, at no additional cost
policy enforcement and attack containment
Hardware-based virtual routing and forwarding (VRF) support on Enterprise-wide cost reduction through hardware consolidation
OmniSwitch 6855-U24X to achieve network segmentation and security without additional
hardware installation
Advanced, out-of-the-box auto- configuration, Link Layer Automated switch setup and configuration, and end-to-end VLAN
Discovery Protocol (LLDP) network policies and dynamic VLAN provisioning support cost-effective installation and deployment
allocation
Ready for Metro Ethernet access: VLAN stacking, multicast switch- Simplifies Metro Ethernet network OA&M for service providers
ing, Dynamic Host Configuration Protocol (DHCP) snooping/ option
82, ITU-T Y.1731, IEEE 802.1ag, IEEE 802.3ah and MAC-Forced
Forwarding (MEF 9/14 compliant)
FeAtuReS BeneFitS

Enhanced Unified Access features for converged campus network Unified Access and Application fluent Networks provide resilient
solutions architecture with automated controls, enhanced security and simpli-
• SIP Fluency to provision & monitor QOS treatment of SIP flows fied management for both wired and wireless users resulting in
• Airgroup™ Network Services for Bonjour speaking devices reduced operational complexity & lesser cost.
• Integrated Policy with User Network Profile User Network Profiles add intelligence to the network to automatically
• Citrix VDI fluency enables differentiated services for VDI flows adapt as users move around the enterprise network.
Integration of services enable employees to access same applica-
tions and service across wired and wireless access and thus gives a
consistent, seamless user experience.
Enables deployment of advanced , secure BYOD services OS6855 offers flexible deployment options for BYOD services which
in enterprise networks*: does not require a forklift upgrade and protects customer investment.
• Advanced zero-touch guest management capabilities Automatic on-boarding and 802.1x provisioning of user devices helps
• Device on-boarding and automated 802.1x provisioning in IT operation simplification and increased wired LAN security.
• Device posture/health check, and fingerprinting,
Provides improved control and security over corporate data/applica-
• Application management
tions for mixed personal and corporate environment.

* Requires ClearPass

Alcatel-lucent OmniSwitch 6855-u24x OmniSwitch 6855-P14

OmniSwitch 6855 models • Two 10 Gigabit Ethernet SFP+ ports for • 12 10/100/1000 RJ-45 copper ports
stacking or uplinks • 12 PoE-capable ports
The OmniSwitch 6855 family offers
customers an extensive selection of Gigabit • 22 SFP ports • Two SFP ports
and 10 Gigabit Ethernet fixed-configura- • Two combo ports • Fanless design
tion switches and power supply options • Up to four units in a stack
that accommodate most needs. Models
offered include industrial-strength PoE
and non-PoE models in a IU form factor.

Fiber models with 10 Gigabit


Ethernet OmniSwitch 6855-24
OmniSwitch 6855-u10 • 20 10/100/1000 RJ-45 copper ports
Copper models with PoE
• Eight SFP ports OmniSwitch 6855-14 • Four PoE-capable ports
• Two RJ-45 10/100/1000 copper ports • 12 10/100/1000 RJ-45 copper ports • Four combo ports
• Fanless design • Four PoE-capable ports
• Two SFP ports
• Four combo ports
• Fanless design

All PoE models support 15.4 W per


port PoE (compliant with IEEE 802.3af
standard).
Technical Specifications
OS6855-P14 OS6855-14 OS6855-24 OS6855-u10 OS6855-u24X
Number of ports
Maximum 10 Gigabit Ethernet 0 0 0 0 2
Maximum 10/100/100Base-T 12 12 24 2 2
RJ-45
Maximum SFP connectors 2 2 4 8 24
PoE 12 4 4 0 0
Combo 0 0 4 0 2
Physical dimensions
Width 21.6 cm 21.6 cm 43.8 cm 21.6 cm 43.8 cm
(8.50 in.) (8.50 in.) (17.25 in.) (8.50 in.) (17.25 in.)
Height 4.4 cm (1.73 in.) 4.4 cm (1.73 in.) 4.4 cm (1.73 in.) 4.4 cm (1.73 in.) 4.4 cm (1.73 in.)
Depth (no PS shelf attached) 26 cm (10.25 in.) 26 cm (10.25 in.) 27.4 cm (10.78 in.) 26 cm (10.25 in.) 27.4 cm (10.78 in.)
Weight (no PS) 2.7 kg (5.96 lb.) 2.42 kg (5.28 lb.) 3.78 kg (8.34 lb.) 2.42 kg (5.28 lb.) 5.3 kg (11.68 lb.)
Weight (with one PS and tray) 3.83 (8.44 lb.) 3.55 kg (7.82 lb.) 5.35 kg (11.8 lb.) 3.55 kg (8.2 lb.) 6.87 kg (15.14 lb.)

AlcAtel-lucent OmniSwitch 6855


Alcatel-Lucent Enterprise Data sheet
2
OS6855-P14 OS6855-14 OS6855-24 OS6855-u10 OS6855-u24X
Environment
Operating temperature -40°C to +70°C -40°C to +70°C -40°C to +75°C -40°C to +70°C -40°C to +70°C
(-40°F to +158°F) (-40°F to +158°F) (-40°F to +167°F) (-40°F to +158°F) (-40°F to +158°F)
Storage temperature -40°C to +85°C -40°C to +85°C -40°C to +85°C -40°C to +85°C -40°C to +85°C
(-40°F to +185°F) (-40°F to +185°F) (-40°F to +185°F) (-40°F to +185°F) (-40°F to +185°F)
Humidity (operating and storage) 5% to 95% 5% to 95% 5% to 95% 5% to 95% 5% to 95%
MTBF* (hours) 387,985 430,389 529,644 508,942 373,980
Fanless design Yes Yes No Yes Yes***
Acoustic (dB) at <50°C Silent Silent 33 Silent Silent
Acoustic (dB) – all fans on N/A N/A 57 N/A N/A
Power consumption**** 33.5 W 30 W 46 W 25 W 51 W
Heat dissipation** (BTU/hr) 114.3 102.4 157 85.3 174

• MTBF values calculated at 25•C (77°F) for the switch only


** Sufficient spacing required for airflow and heat dissipation
*** The OS6855-U24X chassis is fanless. The etxernal DC power supplies have fans.
**** Power consumption was measured from the AC input power using nominal input voltage of 120 V AC and runnnig full traffic on all ports.

Combo ports are ports individually There is no interruption of service when unit. A power shelf provided with the unit
configurable to be 10/100/1000 Base-T or a new power supply is installed or an old can slide into the rear of the switch and is
1000Base-X, which spuport SFP transceiv- one replaced. used to hold two power supplies.
ers for short, long and very long distances.
Power supplies for OmniSwitch Any power supply can be remotely
Gigabit fiber interfaces on the OmniSwitch 6855-14, OmniSwitch 6855-P14 connected using a cable, which enables
6855-U10 and OmniSwitch 6855-U24X and OmniSwitch 6855-u10 rack mounting using the mounting ears
models support Gigabit SFP or 100Base-X The power supplies for the half rack mod- provided with the unit. This feature allows
SFP optical transceivers. See the full list of els come in the form of a power brick in for space-sensitive installations requiring
supported transceivers at the end of the either AC or DC variant. A separate power reduced depth (for example, in a wall-
data sheet. brick provides PoE power and is available mounted cabinet).
for purchase when PoE is required.
Power supplies Indicators

OmniSwitch 6855 models support redun- Power supplies for • Per-port LEDs: link/activity/PoE
dant, hot-swappable AC, DC or PoE power OmniSwitch 6855-24 and • System LEDs: OK (switch HW/SW status)
supplies. The primary and the backup OmniSwitch 6855-U24X • PS1/PS2: primary and/or redundant power
power supply units are external, allowing The primary and the backup power supply status
for easier maintenance and replacement. supplies for the 24 port models are • 7-segment LED on OS6855-U24X
modular and connect to the rear of the indicating the operational mode
and stack number

POWER SUPPLY MODELS DESCRIPTION


OS6855-PSS PSU for OS6855-14 and OS6855-U10; 90 V to 240 V AC, 50 Hz to 60 Hz AC, 40 W, 12 V AC-DC
OS6855-PSS-P PSU for PoE on OS6855-14; 66 W, 48 V PoE, AC-DC
OS6855-PSS-D PSU for 6855-14 and OS6855-U10, 40 W, -48 V and 24 V input to 12 V DC-DC
OS6855-PSS-P-D PSU for PoE on OS6855-14; 66 W, -48 V input DC-DC
OS6855-PSSPH PSU for PoE on OS6855-P14; 185 W PoE, AC-DC
OS6855-PSL-C Fanless PSU for OS6855-U24X; 90 V to 240 V AC, 50 Hz to 60 Hz AC; 80 W, 12 V, AC-DC
OS6855-PSL-P PSU for OS6855-24; 90 V to 240 V AC, 50 Hz to 60 Hz AC; 160 W, 48 VC PoE, 12 V, AC-DC
OS6855-PSL-D PSU for OS6855-24 and OS6855-U24X; 80 W, -48 V/12 V DC-DC
OS6855-PSL-DL PSU for OS6855-24 and OS6855-U24X; 80 W, 24 V/12 V DC-DC
Physical dimensions Weight Depth Width Height
OS6855-PSS, OS6855-PSS-P, 0.65 kg (1.3 lb.) 14 cm (5.5 in.) 8.1 cm (3.2 in.) 4.1 cm (1.6 in.)
OS6855-PSS-D
OS6855-PSS-P-D 0.5 kg (1.1 lb.) 16.6 cm (6.53 in.) 8 cm (3.15 in.) 4.4 cm (1.73 in.)
OS6855-PSSPH 1.03 kg (2.27 lb.) 11.35 cm (4.47 in.) 6.3 cm (2.48 in.) 12.52 cm (4.93 in.)
Power brick tray 0.5 kg (1.35 lb.) 19.1 cm (7.5 in.) 21.6 cm (8.5 in.) 4.4 cm (1.73 in.)
Power supply (AC, DC or PoE) 1.00 kg (2.20 lb.) 16.5 cm (6.5 in.) 16 cm (6.3 in.) 4.4 cm (1.73 in.)
Power supply tray 0.60 kg (1.32 lb.) 17.8 cm (7.0 in.) 35.3 cm (13.88 in.) 4.4 cm (1.73 inn.)

AlcAtel-lucent OmniSwitch 6855


Alcatel-Lucent Enterprise Data sheet
3
Compliance and • EN 50121-4: 2006 for Class A device Stacking capacity for OS6855-U24X

certfications • IEEE 1613 (C37.90.x) • Full duplex/aggregated: 20/40 Gbps


• C37.90.3 (ESD) Layer 2 switching
Commercial
EMI/EMC • C37.90.2 (Radiated RFI) • Maximum number of configured VLANs:
• IEEE 1613 C37.90.1 (Fast Transient) 4K
• FCC CRF Title 47 Subpart B (Class A)
• IEEE 1613 C37.90.1 (Oscillatory) • Maximum MAC addresses per system: 16K
• VCCI (Class A)
• IEEE 1613 C37.90 (H.V. Impulse) • Jumbo frame support: 9216 bytes
• AS/NZS 3548 (Class A)
• CE marking for European countries (Class A) • IEEE 1613 C37.90 (Dielectric Strength)
Simplified manageability
• EN 5502:2006 (Emission Standard)
Military Management interfaces
• EN 61000-3-3:1995 +A2:2005
• MIL-STD-810F (shock and vibration)*** • Intuitive, familiar Alcatel-Lucent CLI
• EN 61000-3-2:2006 reduces training costs
• MIL-STD-901D (shock)**
• EN 55024:1998 +A1:2001 +A2:2003 • Easy to use, point-and-click, web-based
(Immunity Standards) • MIL-STD-167-1 (vibration)**
element manager (WebView) with built-in
¬ EN 61000-4-2: 1995+ A1:1998 • MIL-STD-810F**: Methods 500, 501, 502,
help for easy configuration
+A2:2001 503, 504, 505, 506, 507, 508, 509, 510,
• Integrated with Alcatel-Lucent OmniVista™
512, 514, 515, 516, 520, 521
¬ EN 61000-4-3:2006 products for network management
• MIL-STD-461E**: CE101, CE102, CS101,
¬ EN 61000-4-4:2004 • Full configuration and reporting using
CS114, CS115, CS116, RE101, RE 102,
¬ EN 61000-4-5:2006 SNMPv1/2/3 across all OmniSwitch
RS101, RS103
¬ EN 61000-4-6:2007 families to facilitate third-party network
management system integration
¬ EN 61000-4-8:1993 +A1:2001 Safety agency certifications
• Remote switch access using Telnet or
¬ EN 61000-4-11:2004 • US UL 60950 Secure Shell (SSH)
• IEEE802.3: Hi-pot Test (2250 V DC on all • IEC 60950-1:2001; all national deviations • File upload using USB, TFTP, FTP, SFTP, or
Ethernet ports)
• EN 60950-1: 2001; all deviations SCP for faster configuration
• EN 50121-4
• CAN/CSA-C22.2 No. 60950-1-03 • Human-readable ASCII-based configuration
neBS**
• NOM-019 SCFI, Mexico files for off-line editing, bulk configuration
• GR-63-CORE (temperature, humidity, and out-of-the-box auto-provisioning
• AS/NZ TS-001 and 60950:2000, Australia
altitude, contamination)
Monitoring and troubleshooting
• UL-AR, Argentina
• GR-1089-CORE Issue 4 (section 2-3)
• Local (on the flash) and remote server
• UL-GS Mark, Germany
• GR-1089-CORE Issue 4 (section 3.2, 4-10) logging: Syslog and command log
Industrial • EN 60825-1 Laser
• Port-based mirroring for trouble- shooting
• IEC 60870-2-2 (operational temperature) • EN 60825-2 Laser
and lawful interception; supports four
• IEC 60068-2-1 (temperature type test – cold) • CDRH Laser sessions with multiple sources-to-one
• IEC 60068-2-2 (temperature type test – hot) * Note: Class A with UTP cables. destination
** Contact for availability
• IEC 60721-3-1: Class 1K5 (storage *** All models except OS6855-P14 are MIL-810F • Policy-based mirroring allows selection of
temperature)
compliant the type of traffic to mirror by using QoS
policies
• IEC 68-2-30: 5% to 95% non-condensing
humidity Detailed Product Features • Remote port mirroring facilitates passing
mirrored traffic through the network to a
• IEC 60255-21-2 (mechanical chock) Interface and speeds
remotely connected device
• IEC 60255-21-1 (vibration) Switching capacity
• Port monitoring feature allows capture
EMI/EMC • OS6855-U10/-U10D: 10 Gbps Full Duplex
of Ethernet packets to a file to assist in
• EN 61131-2 or 20 Gbps aggregate
troubleshooting
• EN 61000-6-4: 2007 (emission) • OS6855-14/-14D/ -P14: 14 Gbps Full
• sFlow v5 and RMON for advanced
Duplex or 28 Gbps aggregate
• EN 61000-6-2: 2005 (immunity) monitoring and reporting capabilities for
• OS6855-24/-24D/-24DL: 24Gbps Full statistics, history, alarms and events
• EN 55024: 1998 (immunity)
Duplex or 48Gbps aggregate
¬ IEC 61000-4-3 • IP tools: ping and trace route
• OS6855-U24X/-U24XD/-U24XDL: 48Gbps
¬ IEC 61000-4-12 • Y.1731 and IEEE 802.1ag Ethernet
Full Duplex or 96Gbps aggregate
operations, administration and
¬ IEC 61000-4-16 Layer 2 throughput ( Mp/s)
maintenance (OA&M): Connectivity
¬ IEC 61000-4-17 • OS6855-U10/-U10D: 14.9 Mp/s Fault Management and performance
¬ IEC 61000-4-29 • OS6855-14/-14D/-P14: 20.8 Mp/s measurements (layer-2 ping and link trace)
• IEC 60255-5 • OS6855-24/-24D/-24DL: 35.7 Mp/s • IEEE 802.3ah Ethernet in the First Mile
• IEC 61850-3 (Electric Power Substations) • OS6855-U24X/-U24XD/-U24XDL: (EFM) for link monitoring, remote fault
• IEC 62236-4:2008 – Railway applications; 65.5 Mp/s detection, and loop- back control (layer-1
Electromagnetic compatibility – Part 4 ping)

AlcAtel-lucent OmniSwitch 6855


Alcatel-Lucent Enterprise Data sheet
4
• Dying Gasp support via SNMP and syslog • IEEE 802.3ad Link Aggregation Control • Microsoft Active Directory authentication
messages: Protocol (LACP) and static LAG groups snooping (Kerberos)
¬ Unidirectional Link Detection (UDLD) across modules • Bring Your Own Device (BYOD) – Enables
detects and disables unidirectional links • Dual-home link support for sub-second deployment of advanced, secure BYOD
on fiber optic interfaces. link protection without STP services in enterprise networks*:
¬ Digital Diagnostic Monitoring (DDM): • Virtual Router Redundancy Protocol on-boarding of Guest, IT/non-IT issued and
Real-time diagnostics of fiber (VRRP) to provide highly available routed silent devices; Restriction/Remediation of
connections for early detection of environments traffic from non-compliant devices. Uses
optical signal deterioration RADIUS CoA to dynamically enforce User
• Bidirectional Forwarding Detection (BFD)
Network Profiles based on Authentication,
¬ Link Monitoring: link flap detection for fast failure detection and reduced
Profiling, Posture check of devices
and link error counts to identify bad re-convergence times in a routed
* Requires ClearPass
connections and automatically make environment
Containment, monitoring and quarantine
adjustments to use the links that are good • Broadcast, unknown unicast and multicast
• Support for Alcatel-Lucent OmniVista
¬ Time Domain Reflectometry (TDR): used storm control to avoid degradation in
2500 Quarantine Manager and quarantine
for locating break or other discontinuity overall system performance
VLAN
in copper cables. • Redundant and hot-swappable power
• Learned Port Security (LPS) or MAC
Network configuration supplies, transceivers modules offering
address lockdown secures the network
• Auto-negotiating 10/100/1000 ports uninterruptable service
access on user or trunk ports based on
automatically configure port speed and • Dual image and dual configuration file MAC address
duplex setting storage provides backup
• DHCP Snooping, DHCP IP and Address
• Auto MDI/MDIX automatically configures • Stacking capability (OS6855- U24X only) Resolution Protocol (ARP) spoof protection
transmit and receive signals to support for virtual chassis redundancy. Up to 10-km
• Embedded traffic anomaly detection (TAD)
straight- through and crossover cabling fault-tolerant remote stacking supported.
monitors traffic patterns typical for worm-
• BOOTP/DHCP client with option 60 allows • Split Stack Protection: Auto detection and like viruses and either shuts down the port
auto-configuration of the switch for recovery of stacks splitting into sub-stacks or reports to the management system
simplified deployment due to multiple stacking-link or stack
• ARP poisoning detection
• DHCP v4/v6 relay to forward client elements failure*
* Contact for availability • IP Source Filtering as a protective and
requests to a DHCP server
effective mechanism against ARP attacks
• Alcatel-Lucent Mapping Adjacency Advanced security • ACLs to filter out unwanted traffic
Protocol (AMAP) for building topology
Access control including denial of service (DoS) attacks;
maps
• AOS Access Guardian framework for flow-based filtering in hardware (layer 1
• IEEE 802.1AB LLDP with MED extensions to layer 4)
comprehensive user-policy- based
for automated device discovery and IP
network access control (NAC) • Support of Microsoft® Network Access
phone provisioning
• Autosensing 802.1X multi-client, multi- Protection (NAP)
• Multiple VLAN Registration Protocol
VLAN support • Bridge Protocol Data Unit (BPDU) blocking
(MVRP) and GARP VLAN Registration
• MAC-based authentication for non-802.1x automatically shuts down user ports to
Protocol (GVRP) for 802.1Q/1ak-compliant
hosts prevent topology loops if an STP BPDU
VLAN pruning and dynamic VLAN creation
• Web based authentication (captive portal): packet is seen
• Auto-QoS for switch management and IP
A customizable web portal residing on the • STP Root Guard prevents edge devices
phone traffic
switch from becoming STP root nodes
• Network Time Protocol (NTP) for network-
• IEEE 802.1X and MAC-based • LLDP Security mechanism for rogue device
wide time synchronization
authentication, with group mobility and detection and restriction
“guest” VLAN support
Resiliency and high availability
• Host integrity check (HIC) agent on each Converged networks
• ITU-T G.8032 v2 Ethernet Ring switch makes it an HIC enforcer and PoE
Protection(ERP) designed for loop facilitates endpoint device control for
• Dynamic PoE allocation delivers only the
protection and fast convergence times company policy compliance; quarantine
power needed by the attached device
(sub 50 ms) in ring topologies and remediation are supported as required
up to the total power budget for most
• Ring Rapid Spanning Tree Protocol (RRSTP) • User Network Profile (UNP) simplifies NAC efficient power consumption
optimized for ring topology to provide by dynamically providing pre-defined
• PoE models support Alcatel- Lucent IP
less than 100-ms convergence time policy configuration to authenticated
phones and WLAN access points, as well
• IEEE 802.1s Multiple Spanning Tree clients – VLAN, ACL, bandwidth, HIC
as any IEEE 802.3af-compliant end device
Protocol (MSTP) encompasses IEEE 802.1D • SSH for secure CLI session with public key
• Configurable per-port PoE priority and
Spanning Tree Protocol (STP) and IEEE infrastructure (PKI) support
max power for power allocation
802.1w Rapid Spanning Tree Protocol
• TACACS+ client allows for authentication QoS
(RSTP)
authorization and accounting (AAA) with a
• Per-VLAN spanning tree (PVST+) and • Priority queues: Eight hardware- based
remote TACACS+ server
Alcatel-Lucent 1x1 STP mode queues per port for flexible QoS
• Centralized RADIUS and Light- weight management
Directory Access Protocol (LDAP) user
authentication

AlcAtel-lucent OmniSwitch 6855


Alcatel-Lucent Enterprise Data sheet
5
• Traffic prioritization: Flow-based QoS with • Neighbor Discovery Protocol (NDP) Supported Standards
internal and external prioritization (also • DHCP relay for IPv6 IEEE standards
known as re-marking) iPv4/iPv6 multicast
• IEEE 802.1D (STP)
• Bandwidth management: Flow- based • Internet Group Management Protocol
bandwidth management, ingress rate • IEEE 802.1p (CoS)
(IGMP) v1/v2/v3 snooping for optimized
limiting; egress rate shaping per port • IEEE 802.1Q (VLANs)
multicast traffic
• Queue management: Configurable • IEEE 802.1ad (Provider Bridges)
• Protocol Independent Multicast – Sparse
scheduling algorithms: Strict Priority Mode (PIM-SM)/Protocol Independent • IEEE 802.1ag (Connectivity Fault
Queuing (SPQ), Weighted Round Robin Multicast – Dense Mode (PIM-DM) Management)
(WRR) and Deficit Round Robin (DRR) • IEEE 802.1ak (Multiple VLAN Registration
• Distance Vector Multicast Routing Protocol
• Congestion avoidance: Support for End- (DVMRP) Protocol)
to-End Head-of-Line (E2E-HOL) blocking • IEEE 802.1s (MSTP)
• Multicast Listener Discovery (MLD) v1/v2
prevention and flow control
snooping for optimized multicast traffic • IEEE 802.1w (RSTP)
• LLDP network polices for dynamic
Metro Ethernet access • IEEE 802.1X (Port-based Network Access
designation of VLAN-ID and layer-2/
• Ethernet services support per IEEE Control)
layer-3 priority for IP phones
802.1ad Provider Bridge services (also • IEEE 802.3i (10Base-T)
• Auto-QoS for switch management traffic
known as Q-in-Q or VLAN stacking): • IEEE 802.3u (Fast Ethernet)
as well as traffic from Alcatel-Lucent IP
¬ Service VLAN (SVLAN) and Customer • IEEE 802.3x (Flow Control)
phones
VLAN (CVLAN) transparent LAN services
• Differentiated Services for Virtual Desktop • IEEE 802.3z (Gigabit Ethernet)
¬ Ethernet network-to-network interface
Interface (VDI) flows. One-touch QOS • IEEE 802.3ab (1000Base-T)
(NNI) and user network interface (UNI)
support for Citrix VDI • IEEE 802.3ac (VLAN Tagging)
services
Fluent network for voice, video and data
¬ Service Access Point (SAP) Profile • IEEE 802.3ad (Link Aggregation)
• Session Initiation Protocol (SIP) detection, • IEEE 802.3ae (10G Ethernet)
identification
session monitoring and tracking
¬ CVLAN to SVLAN translation and • IEEE 802.3af (Power over Ethernet)
• Provides real time conversation quality
mapping
information contained in the SIP packets
concerning packet loss, delay, jitter, MOS • Ethernet OA&M compliant with ITU ITU-T standards
score, R-Factor in real time Y.1731 and IEEE 802.1ag version 8.1 • ITU-T G.8032: Draft (June 2007) Ethernet
for connectivity fault and performance Ring Protection
• SIP profile for QOS, priority tuning for
management and IEEE 802.3ah EFM for
end-to-end processing • ITU-T Y.1731 OA&M fault and performance
link OA&M
• Multicast DNS Relay: Bonjour protocol management
• Service Assurance Agent (SAA) for SLA
Support for wired Airgroup™
compliance validation
IETF standards
• Customer provider edge (CPE) test head
Layer-3 routing and multicast iPv4
traffic generator and analyzer tool used
iPv4 routing • RFC 2003 IP/IP Tunneling
in the metro Ethernet network to validate
• Multiple VRF for network Segmentation customer Service Level Agreements (SLA) • RFC 2784 GRE Tunneling
and Inter-VRF route leaking • TR-101 PPPoE Intermediate Agent OSPF
• Static routing, Routing Information allowing for the PPPoE network access • RFC 1253/1850/2328 OSPF v2 and MIB
Protocol (RIP) v1 and v2 method • RFC 1587/3101 OSPF NSSA Option
• Open Shortest Path First (OSPF) v2, • MAC-Forced Forwarding support according • RFC 1765 OSPF Database Overflow
Border Gateway Protocol (BGP) v4 to RFC 4562 • RFC 2154 OSPF MD5 Signature
• Generic Routing Encapsulation (GRE) • Private VLAN feature for user traffic • RFC 2370/3630 OSPF Opaque LSA
and IP/IP tunneling segregation
• RFC 3623 OSPF Graceful Restart
• Graceful restart extensions for OSPF • DHCP Option 82: Configurable relay agent
RiP
and BGP information
• RFC 1058 RIP v1
• VRRP v2 • IP Multicast VLAN (IPMVLAN) for
• RFC 1722/1723/1724/2453/1724 RIP v2
• DHCP relay (including generic UDP relay) optimized multicast replication at the edge
and MIB
• ARP saving network core resources
• RFC 1812/2644 IPv4 Router Requirements
iPv6 routing • Optimized Ethernet access services delivery
• RFC 2080 RIPng for IPv6
• Static routing ¬ Network bandwidth protection against
BGP
overload of video traffic
• Routing Information Protocol Next
¬ Multicast streams isolation from multiple • RFC 1269/1657 BGP v3 & v4 MIB
Generation (RIPng)
content providers over the same • RFC 1403/1745 BGP/OSPF Interaction
• OSPF v3
interface • RFC 1771-1774/2842/2918/3392 BGP v4
• BGP v4 (with extensions to IPv6 routing)
• MEF 9 and 14 certified • RFC 1965 BGP AS Confederations
• Graceful restart extensions for OSPF
• Managed by Alcatel-Lucent 5620 Service • RFC 1966 BGP Route Reflection
and BGP
Aware Manager • RFC 1997/1998 BGP Communities
• VRRP v3
Attribute

AlcAtel-lucent OmniSwitch 6855


Alcatel-Lucent Enterprise Data sheet
6
• RFC 2042 BGP New Attribute Manageability QoS
• RFC 2385 BGP MD5 Signature • RFC 854/855 Telnet and Telnet options • RFC 896 Congestion Control
• RFC 2439 BGP Route Flap Damping • RFC 959/2640 FTP • RFC 1122 Internet Hosts
• RFC 2545 BGP-4 Multiprotocol Extensions • RFC 1155/2578-2580 SMI v1 and SMI v2 • RFC 2474/2475/2597/3168/3246
for IPv6 Inter-Domain Routing • RFC 1157/2271 SNMP DiffServ
• RFC 2796 BGP Route Reflection • RFC 1212/2737 MIB and MIB-II • RFC 2697 srTCM
• RFC 2858 Multiprotocol Extensions for • RFC 1213/2011-2013 SNMP v2 MIB • RFC 2698 trTCM
BGP-4 • RFC 1215 Convention for SNMP Traps • RFC 3635 Pause Control
• RFC 3065 BGP AS Confederations • RFC 1350 TFTP Protocol Others
iP multicast • RFC 768 UDP
• RFC 1573/2233/2863 Private Interface MIB
• RFC 1075 DVMRP • RFC 791/894/1024/1349 IP and IP/
• RFC 1643/2665 Ethernet MIB
• RFC 1112 IGMP v1 Ethernet
• RFC 1901-1908/3416-3418 SNMP v2c
• RFC 2236/2933 IGMP v2 and MIB • RFC 792 ICMP
• RFC 2096 IP MIB
• RFC 2362/4601 PIM-SM • RFC 793/1156 TCP/IP and MIB
• RFC 2131 DHCP server/client
• RFC 2365 Multicast • RFC 826/903 ARP and Reverse ARP
• RFC 2570-2576/3411-3415 SNMP v3
• RFC 2710 — Multicast Listener Discovery • RFC 919/922 Broadcasting internet
• RFC 2616 /2854 HTTP and HTML
for IPv6 datagram
• RFC 2667 IP Tunneling MIB
• RFC 2715/2932 Multicast Routing MIB • RFC 925/1027 Multi LAN ARP/ Proxy ARP
• RFC 2668/3636 IEEE 802.3 MAU MIB
• RFC 2934 PIM MIB for IPv4 • RFC 950 Subnetting
• RFC 2674 VLAN MIB
• RFC 3376 IGMPv3 • RFC 951 BOOTP
• RFC 3414 User based Security model
• RFC 4541 Considerations for IGMP • RFC 1151 RDP
• RFC 4251 Secure Shell Protocol
and MLD snooping• RFC 5060 Protocol • RFC 1191/1981 Path MTU Discovery
architecture
Independent Multicast MIB • RFC 1256 ICMP Router Discovery
• RFC 4252 The Secure Shell (SSH)
• RFC 5132 IP Multicast MIB • RFC 1305/2030 NTP v3 and Simple NTP
Authentication Protocol
• RFC 5240 PIM Bootstrap Router MIB • RFC 1493 Bridge MIB
• RFC 4878 OA&M Functions on Ethernet-
iPv6
Like Interfaces • RFC 1518/1519 CIDR
• RFC 1886/3596 DNS for IPv6
Security • RFC 1541/1542/2131/3396/3442 DHCP
• RFC 2292/2553/3493/3542 IPv6 Sockets
• RFC 1321 MD5 • RFC 1757/2819 RMON and MIB
• RFC 2373/2374/3513/3587 IPv6
• RFC 2104 HMAC Message Authentication • RFC 2131/3046/3315/4649/6221 DHCP/
Addressing
• RFC 2138/2865/2868/3575/2618 RADIUS BOOTP Relay
• RFC 2460//2462/2464 Core IPv6
Authentication and Client MIB • RFC 2132 DHCP Options
• RFC 2461 NDP
• RFC 2139/2866/2867/2620 RADIUS • RFC 2251 LDAP v3
• RFC 2463/2466/4443 ICMP v6 and MIB Accounting and Client MIB • RFC 2338/3768/2787 VRRP and MIB
• RFC 2452/2454 IPv6 TCP/UDP MIB • RFC 2228 FTP Security Extensions • RFC 3021 Using 31-bit prefixes
• RFC 2893/4213 IPv6 Transition • RFC 2267 Network Ingress Filtering • RFC 3060 Policy Core
Mechanisms
• RFC 2284 PPP EAP • RFC 3176 sFlow
• RFC 3056 IPv6 Tunneling
• RFC 2869 RADIUS Extension • RFC 4562 MAC-Forced Forwarding
• RFC 3542/3587 IPv6
• RFC 3579 RADIUS for EAP • RFC 5880, 5881, 5882 BFD
• RFC 3595 TC for Flow Label
• RFC 3576 Dynamic Authorization
• RFC 4007 IPv6 Scoped Address Extensions to RADIUS
Architecture
• RFC 4193 Unique Local IPv6 Unicast
Addresses

AlcAtel-lucent OmniSwitch 6855


Alcatel-Lucent Enterprise Data sheet
7
OmniSwitch 6588 ordering
OmniSwitch 6855 models
OS6855-14, Layer-3 fixed-configuration fanless switch in a 1U form factor. It has 12 RJ-45 connectors individually configurable to
OS6855-14D 10/100/1000Base-T, four of which are PoE–capable, and two SFP ports that support various distances. An OS6855-PSS
or OS6855-PSS-D power supply respectively is included in the bundle.
OS6855-P14 Layer-3 fixed-configuration fanless switch in a 1U form factor. It has 12 RJ-45 connectors individually configurable to
10/100/1000Base-T, all of which are PoE capable, and two SFP ports that support various distances. The bundle comes
with system power supply (OS6855-PSS), PoE power supply (OS6855-PSSPH), power shelves, and power cord.
OS6855-U10 Layer-3 fixed-configuration fanless switch in a 1U form factor. It has two RJ-45 connectors individually configurable
OS6855-U10D to 10/100/1000Base-T, and eight SFP ports that support various distances. An OS6855-PSS or OS6855-PSS-D power
supply respectively is included in the bundle.
OS6855-24, Layer-3 fixed-configuration switch in a 1U form factor. It has 20 RJ-45 connectors individually configurable to
OS6855-24DL, 10/100/1000Base-T, four of which provide PoE and four combo ports. On the combo ports, either copper or fiber
OS6855-24D can be used on a one-for-one basis. An OS6855-PSL-P, OS6855-PSL-D or OS6855-PSL-DL power supply respectively is
included in the bundle.
OS6855-U24X, Layer-3 fixed-configuration switch in a 1U form factor. It has two 10G SFP+ ports, 22 SFP ports that support
OS6855-U24XDL, various distances, and two combo ports. On the combo ports, either RJ-45 connectors individually configurable
OS6855-U24XD to 10/100/1000Base-T, or fiber SFP can be used on a one-for-one basis. The 10G SFP+ ports can be used either
as uplinks or as stacking ports. An OS6855-PSL-C, OS6855-PSL-DL or OS6855-PSL-D power supply respectively is
included in the bundle.
OmniSwitch 6855 backup power supplies for OS6855-14, -P14 and –U10
OS6855-PSS OS6855-PSS power brick AC power supply. Provides only system power. Does not provide PoE. Ships with country
specific power cord.
OS6855-PSS-P OS6855-PSS-P power brick AC power supply. Provides PoE only power to one OS6855-14. Ships with country specific
power cord.
OS6855-PSS-D OS6855-PSS-P-D power brick 48V DC power supply. Provides PoE only power to one OS6855-14
OS6855-PSS-P-D OS6855-PSS-P-D power brick 48V DC power supply. Provides PoE only power to one OS6855-14. Up to 66 W at
-40 to +45C and 42W at ambient -40 to +75C.
OS6855-PSSPH OS6855-PSSPH power brick AC power supply. Provides up to 180W of PoE only power to one OS6855-P14.
OmniSwitch 6855 backup power supplies for OS6855-24 and OS6855-U24X
OS6855-PSL-P OS6855-PSL-P modular AC backup power supply. Provides backup system and PoE power to one OS6855-24 switch.
OS6855-PSL-D OS6855-PSL-D modular -48V DC backup power supply. Provides backup system power to one 24 port 6855 switch.
OS6855-PSL-DL OS6855-PSL-DL modular 24V DC backup power supply. Provides backup system power to one 24 port 6855 switch.
OS6855-PSL-C OS6855-PSL-C fanless modular AC backup power supply. Provides backup system power to one OS6855-U24X switch.
Transceivers All optical transceivers qualified for the OmniSwitch 6855 operate at a wider operating temperature range than the
corresponding commercial types.
iSFP-10G-LR 10G industrial optical transceiver (SFP+). Supports single-mode fiber over 1310 nm wavelength (nominal) with an
LC connector. Typical reach of 10 km.
iSFP-GIG-LH70 1000Base-LH industrial transceiver. Supports single-mode fiber over 1550 nm wavelength (nominal) with an
LC connector. Typical reach of 70 km.
iSFP-GIG-LH40 1000Base-LH industrial transceiver Supports single-mode fiber over 1310 nm wavelength (nominal) with an
LC connector. Typical reach of 40 km.
iSFP-GIG-LX 1000Base-LX industrial transceiver Supports single-mode fiber over 1310 nm wavelength (nominal) with an
LC connector. Typical reach of 10 km.

iSFP-GIG-SX 1000Base-SX industrial transceiver. Supports multimode fiber over 850 nm wavelength (nominal) with an
LC connector. Typical reach of 300 m.
iSFP-GIG-T 1000Base-T Gigabit industrial Ethernet Transceiver (SFP MSA). Supports category 5, 5E, and 6 copper cabling up
to 100 m. SFP supports 10/100/1000 Mb/s and full-duplex mode.
iSFP-GIG-BX-U 1000Base-BX SFP transceiver with an LC type interface. Supports single-mode fiber on a single strand link up to
10 km. Transmits 1310 nm and receives 1490 nm optical signal.
iSFP-GIG-BX-D 1000Base-BX SFP transceiver with an LC type interface. Supports single-mode fiber on a single strand link up to
10 km. Transmits 1490 nm and receives 1310 nm optical signal.
iSFP-100-MM 100Base-FX industrial transceiver with an LC type interface. This transceiver is designed for use over multimode fiber.

AlcAtel-lucent OmniSwitch 6855


Alcatel-Lucent Enterprise Data sheet
8
iSFP-100-SM15 100Base-FX industrial transceiver with an LC type interface. This transceiver is designed for use over single-mode
fiber up to 15 km.
iSFP-100-SM40 100Base-FX industrial transceiver with an LC type interface. This transceiver is designed for use over single-mode
fiber up to 40 km.
iSFP-100-BX-U 100Base-BX industrial transceiver with an SC type interface. This bidirectional transceiver is designed for use over
single-mode fiber on a single strand link up to 20 km point-to-point. This transceiver is normally used in the client
(ONU) and transmits 1310 nm and receives 1550 nm optical signal.
iSFP-100-BX-D 100Base-BX industrial SFP transceiver with an SC type interface. This bidirectional transceiver is designed for use
over single mode fiber on a single strand link up to 20 km point-to-point. This transceiver is normally used in the
central office (OLT) and transmits 1550 nm and receives 1310 nm optical signal.

SeRvice AnD SuPPORt


Warranty
Limited lifetime hardware warranty: Limited to the original owner, and will be provided for up to 5 years after the product’s
End-of-Sales announcement.

www.alcatel-lucent.com Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of
Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented
is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2013 Alcatel-Lucent. All rights reserved. E2013092544EN (November)

You might also like