Single phase inverters 6 to 10 kW

ASW S Series

Models:
ASW6000-S
ASW8000-S
ASW10000-S

Easy-to-install Reliable User-friendly

• Toolless DC connection via Phoenix • International quality standards • 16 A input current, compatible with
Contact connectors • Integrated DC switch bifacial and large area PV modules
• Quick setup and commissioning • IP66 rated design for outdoor use • Online monitoring via Wi-Fi and
with AiSWEI apps AiSWEI apps
• Compact wall mount design • 3 MPPT´s for flexible PV array
design

solplanet.net @Solplanet
Technical Datasheet ASW6000-S ASW8000-S ASW10000-S

Max. PV array power 9000 Wp STC 12000 Wp STC 15000 Wp STC

Max. input voltage 600 V

MPP voltage range / rated input voltage 80 V - 560 V / 360 V

Min. input voltage 80 V

Initial. feed in voltage 100 V


Input (DC)

Max. operating input current 16 A

Max. short circuit current 22.5 A

No. of independent MPPT inputs / strings per MPPT input 3 /1

Rated power 6000 W 8000 W 10000 W

Max. apparent AC power 6600 VA³ 8800 VA³ 11000 VA³

AC nominal voltage 220 V / 230 V / 240 V

AC voltage range 180 V to 295 V

AC grid frequency / range 50 Hz / 45 Hz to 55 Hz


60 Hz / 55 Hz to 65 Hz
Max. output current 30 A 40 A 50 A
Output (AC)

Adjustable power factor range 0.8 leading to 0.8 lagging

Feed-in phases 1

Harmonic distortion (THD) at rated output <3%

Max. efficiency / European efficiency 97.7 % / 97.3 %

DC switch ●

Ground fault monitoring / grid monitoring ●/●


& Protection

DC reverse polarity protection / AC short circuit protection ●/●


Efficiency

All-pole-sensitive residual-current monitoring unit ●

Protection class (according to IEC 62109-1) / I/AC: III; DC :ll


overvoltage category (according to IEC 62109-1)
Dimensions (W / H / D) 503 / 435 / 183 mm

Weight < 18 kg

Operating temperature range -25°C … +60°C

Self-consumption (at night) <1W

Topology Transformerless

Cooling concept Natural convection

Degree of protection (according to IEC 60529) IP66


General data

Climatic category (according to IEC 60721-3-4) 4K4H

Max. permissible value for relative humidity (non-condensing) 100 %

Max. operating altitude 3000 m

DC connection Phoenix contact

AC connection Plug-in connector

Mounting type Wall-mount bracket

LED indicators (Status / Fault/ Communication) ●


Features

Communication interface 1&2


Wi-Fi / 4G / RS485 (Optional)

Certificates and approvals (more available on request) CE, EN50549, IEC62109, IEC62116, IEC61727, IEC61683, IEC60068, IEC61000,
AS/NZS4777, C10/C11

● Standard features / ○ optional features / – not available


1- 2-pin RS485 to approved smart meters for export power control applications
2- DRED supported with RS485 communication for Australia & New Zealand
3- The overload setting is disabled as default for European and AS/NZS4777 grid codes
Version: November 2021

You might also like