Service Training of New Electric

Counterbalance Forklift Truck


Model FB-9
Part 2: Vehicle - 6

Service Engineering Department


Overseas Customer Service Division
Mitsubishi Logisnext Co., Ltd.

1
Part 2 Vehicle Section
<Contents>
1. Overall of FB-9
2. PS Controller Replacement & Memory Initialization
3. Required Work for Delivery
4. Electric Wiring
5. Sensors & Switches
6. Option Addition
7. Periodical Maintenance

© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 2


6. Option Addition

Contents – Option addition


Setting is applied when each optional function is equipped
with the following condition.

6-1. Option addition at factory


(New truck)

6-2. Option addition at dealer


(Before delivery to customer)

6-3. Option addition at customer


(After delivery to customer)

© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 3


6. Option Addition
6-1. Option addition at factory (New truck)

◆Setting is completed at factory.

◆Dealer does not need to install any parts


and any setting.

© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 4


6. Option Addition
6-2. Option addition at dealer (Before delivery to customer)
1) Dealer needs to install parts.
【Case example】
Sales section orders to add forward chime on stock truck.
Parts installation

Buzzer

Chime

Relay
◆Yellow connector
◆After relay installation
for relay
(This photo: W/O relay)
*All additional parts to add forward chime are shown on parts list.
© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 5
6. Option Addition
6-2. Option addition at dealer (Before delivery to customer)
Wiring-reading - 1
TRV
Option part → Dashed line
Controller
Standard part → Solid line

◆System wiring (Standard)


© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 6
6. Option Addition
6-2. Option addition at dealer (Before delivery to customer)
Wiring-reading - 2
Option part → Solid line
Standard part → Dashed line

◆System wiring (Option)


© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 7
6. Option Addition
6-3 Option addition at customer (After delivery to customer)
2) Dealer needs to install parts and setting
【Case example】
Customer orders to add Load meter on customer’s truck.
*This load meter is not for commercial use.
Parts installation *All additional parts for load sensor opt. are shown on parts list.

W/Load meter

Press. sensor

Body harness

© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 8


6. Option Addition
6-3. Option addition at customer (After delivery to customer)

Wiring-reading
HYD controller
Option part → Dashed line
Standard part → Solid line

◆System wiring (Standard)


© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 9
6. Option Addition
6-3. Option addition at customer (After delivery to customer)
Setting - 1
Necessary to perform setting.
Multiple setting is required for this option.
Refer to attached document page? for details

Option Setting screen


LOAD METER SERVICE screen SETTING→OPTION→LOAD METER ①
SERVICE screen CALIBRATION→LOAD METER ➁
SERVICE screen SETTING→OPTION→OVERLOAD BUZZER

◆Multiple Setting*1
*1: Multiple settings must be done on some options.
Refer to the “Service Manual for model FB-9” if you need more details of setting.
© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 10
6. Option Addition
6-3. Option addition at customer (After delivery to customer)
Setting - 2
Option Setting screen
LOAD METER SERVICE screen SETTING→OPTION→LOAD METER ①
SERVICE screen CALIBRATION→LOAD METER ➁
SERVICE screen SETTING→OPTION→OVERLOAD BUZZER ③
① On the SERVICE screen,
Set ON or ON+W for load meter (lift
pressure sensor) function

ON setting: "OVERLOAD" warning isn’t displayed.


ON + WARNING setting: "OVERLOAD" warning is displayed.

◆Multiple Setting*1
*1: Multiple settings must be done on some options.
Refer to the “Service Manual for model FB-9” if you need more details of setting.
© MITSUBISHI LOGISNEXT CO.,LTD. All rights reserved. 11
6. Option Addition
6-3. Option addition at customer (After delivery to customer)
Setting - 3
Option Setting screen
LOAD METER SERVICE screen SETTING→OPTION→LOAD METER ①
SERVICE screen CALIBRATION→LOAD METER ➁
SERVICE screen SETTING→OPTION→OVERLOAD BUZZER ③
On SERVICE screen,
➁Set the default value of the load
meter (Calibration for sensor of
pressure).
③Select buzzer sound ON or OFF
when “OVERLOAD” warning is OVERLOAD BUZZER

appeared.
◆Multiple Setting*1
*1: Multiple settings must be done on some options.
Refer to the “Service Manual for model FB-9” if you need more details of setting