SGA - 9 flue gas analyzer is a gas analysis product for domestic and overseas environmental and industrial
control site monitoring online analysis. The analyzer is based on DOAS and chemometric algorithms (PLS) ,
able to measure SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, CH3I, etc. With high accuracy and reliability, fast
response time, wide self-developed and industrial measurement range and application fields, it has achieved
even surpassed similar products home and abroad. It can be widely used in environmental online monitoring,
industrial process control, safety monitoring, etc.

INDIA
TÜV NORD GROUP

Technical Principle
SGA-9 flue gas analyzer (standard form) uses the long optical path UV DOAS technology. lts optical
technology platform consists of light source, gas chamber, optical and spectroscopic (including diaphragm,
holographic grating, linear array detector) and other optical components. As shown in figure.
Ultraviolet light is sent by the photosource through the optical window into the gas chamber (optical path 0.25
meters), and absorbed by the sample gas flow through the gas chamber. The light carrying sample absorption
information gathers through lens coupled into the fiber and then transmits through the optical fiber into the
spectrometer. After light splitting and photovoltaic conversion, absorption spectrum is obtained and analyzed
to calculate the concentration of the related components in gas.

Sample gas Holographic Gas Cross Interference Table


Light Source grating Measuring Gas
SO2 NO NO2
inlet Interfering Gas

Diaphragm SO2 (500ppm) \ <1ppm no


Gas chamber NO (500ppm) no \ no
NO2 (500ppm) no <1ppm \
Sample gas H2O (No dew) no no no
outlet Linear
CO (1000ppm) no no no
array detector
CO2 (20%) no no no
Optical O2 (21%) no no no

Features
High measurement accuracy
Ÿ Ultraviolet has no moisture absorption, undisturbed by moisture and dust.
Ÿ No cross interference between the gas being measured (see table below).
Ÿ NO and NO2 can be measured at the same time, dispense with converter.
Ÿ Low detection limit
High reliability
Ÿ DOAS + PLS technology, small amount of zero drift & span drift.
Ÿ Modular design.
Ÿ No optical moving parts and no vibration influence.
Ÿ Strong gas cell, low cost.
Ÿ Spectrum automatic adjustment technology, long free maintenance cycle.
Ÿ Light source adopts the pulse source, the service life is 10 years.

info@swanenviron.com www.swanenviron.com
Flue Gas Analyzer (TUV Cert.)

Applications
Wide application scope
Ÿ Chloralkali plant PVC process.
Ÿ Titanium white production process.
Ÿ Sulfur recovery process.
Ÿ Natural gas purification process.
Ÿ Methyl iodide analysis for the coal chemical
industry.
Ÿ On-line air monitoring.
Ÿ Coal-fired power plants.
Ÿ Cement plant.
Ÿ Industrial furnaces.
Ÿ The desulfurization process monitoring.
Ÿ Denitration process monitoring.
Ÿ Incinerators

Easy View Large LCD

Components display Menu screen Operation record


Technical Specifications
Parameter Description
Measurement Component SO2 NO NO2
Range 0~300~3000 ppm 0~300~3000 ppm 0~1500~15000 ppm
Principle DOAS + Stoichiometry (PLS)
Linearity ≤ ± 1.5% F.S.
Repeatability ≤ ± 0.5%
Zero Drift ≤ ± 2% F.S./7d
Span Drift ≤ ± 2% F.S./7d
Response Time < 10s (T90)
Working Temperature -10oC to +40oC
Preheating Time No Preheating
Sample Gas Interface Φ 6 Bi-Lok
Sample Gas Flow Range (0.5~2) L/min, Fluctuation <25%
Sample Gas Pressure The current environmental pressures ±0.1 Bar
Sample Temperature 0oC to +50oC
Sample Gas Humidity No condensation (under sample temperature)
4-20 mA Input Interface 3, configurable, 100Ω load
4-20 mA Output Interface 5, output can be configured, maximum load capacity < 800Ω
Switch Input Interface 6, configurable
Relay Output Interface 14, output can be configured. DC 30V,2A
Communication Interface 1 x RS232, 1 x RS485 (Support the modbus protocol)
Outline Dimension 132mm (H) x 483mm (W) x 378mm (D)
Power Supply 220VAC ± 10%
Power Approx. 100W
Weight Approx. 10kg

info@swanenviron.com www.swanenviron.com
Flue Gas Analyzer (TUV Cert.)

External Dimensions

SWAN ENVIRONMENTAL PVT.LTD.


Plot No: 922 & 935, Swami Ayyappa Co-op Society, Madhapur, Hyderabad, Telangana - 500081
Mob: 9642225204 ; Tel: (040) 40216184/85 ; Fax: (040) 40216183
Email: info@swanenviron.com ; Website: www.swanenviron.com
An ISO 9001:2015 Regional Offices: Ahmedabad, Bengaluru, Bhubaneswar, Chandigarh, Chennai,
Certified Company Delhi, Guwahati, Indore, Kolkata, Mumbai, Raipur & Visakhapatnam

You might also like