7250X Data Sheet
7250X Data Sheet
7250X Data Sheet
com 888-773-2832
7250 Series
The system has been designed to meet The 7250X has an inherently lower cost
EPA Leak Detection and API Inventory design which results in savings. It provides
Monitoring requirements and has the same performance and reliability
been approved for use in hazardous as sensors that consume more power.
environments. Combining low power requirements with
high resolution provides the ultimate
The sensor’s electronics are SMT performance and reliability.
components and integrated into a 5/8”
Specifications
diameter sensing tube. This breakthrough
design eliminates the bulky electronics Power Supply
+5 VDC ± 10% typical (+3.7 VDC min.)
Probe Length
21” to 288”
Voltage Stainless Steel R Style
enclosure at the top of the sensor and
offers greater options for insertion and Current (at +5 VDC) 10mA max. (8mA typical) plus Stainless Steel D, S, M Style 20” to 288”
1.5mA max. (1mA typical) per temperature
mounting. sensor (Probes available in 1” increments) Consult Factory for
longer lengths
The probe is constructed of 316 Stainless Operating Temperature Hazardous Areas Approvals
Steel and comes with a variety of Sensing Area -40°C to 100°C (Non Hazardous Location)
-40°C to 70°C (Hazardous Location) FM
connectors, including a mini connector -40° O Tamb O 70° C
for quick connect applications, a single Electronics Area -40°C to 70°C Class I, II, III, Div. 1
3/4” NPT that can be used with a Steel Probe: 1000 psi max. Groups C, D, E, F, G, T4
Pressure Rating Class I, Div. 2
Float: Dependent. Call Factory.
compression f tting, a double 3/4” NPT for Groups A, B, C, D, T4
Resolution 0.0001” (Protocol Dependent)
mounting with a f ange or bushing, and a Class I, Zone 0, AEx ia IIB T4
Equal to Resolution
1/2” right angle for use in low overhead Repeatability
ATEX
applications. Linearity Probes up to 288”: ± 0.01% of span Ex ia IIB T4
or ± 0.015”, whichever is greater.
NEMKO 05 ATEX 1219X
Hysteresis Probes up to 288”: ± 0.002% of span
The 7250 communicates through a or ± 0.005”, whichever is greater. 0344 II 1G
single signal. The data is transmitted via Null Zone R Style: 9”
asynchronous serial communications D, S and M Style: 8” Sanitary Approvals
2”
and is offered with serial protocol options Dead Band
(3A 74-03)
including an ASCII format. There are Intrinsically Safe Barrier See Installation Drawing E0241200.
Consult Factory.
other options available to OEMs for use
Enclosure Material 316 Stainless Steel IP68
in developing a communications interface Rating
with the probe. The patented design Specifications are subject to change without notice. Patented.
Part Numbering
Dimension Drawing
MMConnector
STYLE
7/8-16 UNS-2A
1.00 .625
2.00"
8.00" NULL ZONE TEMPERATURE SPAN DEAD
BAND
Connector View
Intrinsically Safe Entity Parameters Contact Factory for additional drawings.
Vmax Imax PI CI LI