Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

TV0015C WiMon 100 Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Chemical, Oil and Gas - Products and Technology

Condition monitoring
WiMon100 wireless vibration and temperature sensor

The WiMon100 wireless vibration and temperature sensor 100 mm

paves the way for new and improved strategies for


the maintenance of electric motors and other rotating
equipment. With this sensor, the manual data collection
using handheld monitoring equipment will become a thing
of the past, and the range of equipment that might be
condition monitored is significantly extended.

Due to the cost efficiency, small size and ease of installation The device has an expected battery lifetime of up to five years
and commissioning of the WiMon100 sensor, on line vibration (depending on configuration and temperature) and will reduce
monitoring can now be realized for all types of rotating the cost of maintenance as well as extend the operation time
machines. The autonomous WiMon100 unit comprises a of electric motors and other rotating equipment by enabling
vibration sensor, a temperature sensor, a long-life battery and predictive maintenance. The sensor is designed for installation
communicating using WirelessHART™. WiMon100 units form in harsh environments, certified for ATEX Zone 0 and is ideal
a mesh communication network, if configured for routing, for use in the offshore sector as well as in other industries.
provide a secure, reliable and redundant path from WiMon100 The sensor itself is optimized for non-intrusive installation.
sensor to a gateway and onwards to monitoring and analysis
toolkits. The mounting is by means of a threaded hole which follows
industry standards and allows for a wide range of mounting
methods using commercially available studs or adaptors..

The WiMon 100 sensor is compatible with the


WirelessHART™ infrastructure. Management and analysis is
performed using the WiMon Data Manager. The WiMon Data
Manager handles data acquisition and storage as well as
providing a user interface for commissioning, configuration,
network operation and machine supervision and analyses
Specifications
Temperature measurement
Measurement range -40 0C .. +85 0C
Resolution 0.1 0C
Accuracy +/- 2 0C
Repeatability +/- 0.2 0C
Vibration measurement (overall values)
Velocity
Amplitude range 0,2- 350mm/s (10Hz)
Frequency range 10Hz - 1kHz

TV0015C Lowres © Copyright 2010 ABB. All rights reserved.


Detection type RMS
SKF Acceleration Enveloping Filter 3:
Amplitude range 0,25 - 245m/s 2
Frequency range Acc. 500Hz - 10kHz
Detection Peak to peak
Data processing
A/D conversion 16 bit
Sampling frequency 5,859kS/s
Sampling interval 0,7s
Uploaded waveform resolution 2048 samples / 0,7s
Certification(s)
Wireless communication
EX (Hazardous areas) ATEX Zone 0,
Network standard WirelessHART (HART 7.4)
Ex ia IIC T4 -40 0C/+85 0C
Radio standard IEEE 802.15.4
Radio ETSI
Frequency 2.4 GHz, licene free ISM band
EN 300 328 v.1.7.1
Range (nominal) >50m @ line-of-sight
EN 301 489-1 v.1.9.2
Power
EN 301 489-17 v.2.2.1
Battery type 3.6V AA lithium thionyl chloride Physical
(LI-SOCI2) bobbin cell Weight 0.2 kg

Estimated battery lifetime Up to 5 year battery life, Case material Stainless steel/Thermoplastic

depending on temperature, Mounting 1/4 28 UNF tapped hole


settings and usage; see below. Preferably stud mounted,
mounting torque 5Nm
Operating temperature (C) -40° to -20° -20° to 0° 0° to 40° 40° to 70°

Battery life in years 3 4 5 3 Dimensions 100 x 36 mm


Note 1 Default sensor configuration:
Vibration measurements (velocity and
acceleration enveloping) collected every
hour with static data (overall values)
uploaded
once per hour, and a single set of time For more information, please contact:
waveforms uploaded once per 24h.
Temperature measurement collected
every 5 minutes with all measurements ABB AS
uploaded once per hour. Process Automation Division
Sensor operating as a leaf node (not
routing) Ole Deviks vei 10
Note 2 Continuous operation in the 70 to 85 °C
PO Box 6359 Etterstad
temperature range is not recommended
as it will dramatically shorten battery N-0666 Oslo, Norway
life.
Phone: +47 22 87 20 00
Note 3 Operating a sensor in router mode will in-
crease energy consumption and reduce its
Email: ogp.products@no.abb.com
battery life, the extent of which depends
on the number of neighboring nodes and
amount of data being routed.
www.abb.no/oilandgas

Environmental The contents of this publication are presented for informational purposes only,
and while every effort has been made to ensure their accuracy, they are not to be
Temperature Operation: -40 0C to +85 0C construed as warranties or guarantees, express or implied, regarding the products
or services described herein or their use or applicability. All sales are governed by
Storage : 30 0C maximum
our terms and conditions, which are available on request.
IP class IP66 (dust-tight and resistant to
We reserve the right to modify or improve the designs or specifications of our
powerful water jetting)
products at any time without notice.

You might also like