41-P01 Analog Indicator As-R

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Industry

=41-P01

Analog indicator
AS-R

=41-P02 =41-P01
+211.16 +111.16

Copyright
The transmission as well as the reproduction of these documents, the use and communication of their content is not permitted without
the express written permission of Siemens AG. Offenders will be liable to damages. All rights, including rights created by patent grant
or registration of a utility model or design, are reserved by Siemens AG.

AsiaRunner AR15 VR Version: 1.1


Module SD Date: 30-06-2008
Subsystems and devices E-Part Originator: I MO LM CS P
Copyright © Siemens AG 2008. All rights reserved.
Reg.no. 6.1787.001. Operating Instruction AS-R

Analogue Indicator AS-R

DIN EN ISO 9001


mess a
Copyright © messMa GmbH • All Rights Reserved • 17.05.2006 Seite 1 von 10
Operating Instruction AS-R Reg.no. 6.1787.001.

0. Contents

1 Scope of delivery ..................................................................... Page 4

2 General description .................................................................. Page 4

3 Technical data ......................................................................... Page 5


4 Installation ............................................................................. Page 7

5 Connection .............................................................................. Page 8

6 Conditions for use .....................................................................Page 10


7 Housing design .........................................................................Page 10

8 Connection conditions ................................................................Page 10

9 Maintenance .............................................................................Page 10
CE marking .............................................................................. Page 10

Seite 2 von 10 Copyright © messMa GmbH • All Rights Reserved • 17.05.2006


Reg.no. 6.1787.001. Operating Instruction AS-R

1. Scope of delivery

• Analogue indicator AS-R


• Operating instructions
• 2 fastening brackets and 2 hexagon nuts
• 2 plug components with threaded terminal ends or spring
connectors
• Flat-type female terminal in the insulated housing

2. General description

Function The analogue indicator is designed for use in rail vehicles, for
example as a speedometer, and is used for the analogue
representation of measured variables, based on voltage, current or
frequency changes.

After the connection of the supply voltage the indicator carries out an
initialisation of the stepping motor system and then supplies the
current display value.

An additional voltage input allows the dial illumination intensity to be


controlled.

24 V DC, 36 V DC or 48 to 110 V DC can be used as the nominal


supply voltage.

Two signal LEDs in the dial indicate operating modes, e.g. when
programmed indicator limit values are exceeded or in the event of
error modes.

In addition, a status relay is provided for the output of these


operating modes.

Furthermore, two binary input signals are connected to the indicator,


which can also be used to control the signal LEDs.

The actual indicator position of the indicators can be monitored. This


involves each of the indicator positions measured with a feedback unit
being output to a SUB D25 plug connector via an 8-bit data interface
with a handshake signal.

Moreover, internal monitoring is also possible, which in the event of


an unauthorised tolerance between the actual and target indicator
positions triggers an error response.

All input and output signals are potentially separated from one
another and, with the exception of the interface to the indicator
feedback, from the supply voltage.

Copyright © messMa GmbH • All Rights Reserved • 17.05.2006 Seite 3 von 10


Operating Instruction AS-R Reg.no. 6.1787.001.

3. Technical data

Inputs

Measuring channel:
Potential separation : 1 kV AC
Unit current:
Measuring range : 0/4 ... 20 mA 0 ...15 mA 0 ... 10 mA
Absolute limit values : ± 40 mA ± 30 mA ± 20 mA
Input resistance : 110 Ω ± 1 % 150 Ω ± 1 % 220 Ω ± 1 %

Standard voltage:
Measuring range : 0 ... 10 V 0 ... 40 V 0 ... 6 V
Absolute limit values : ± 20 V + 80 V + 12 V
Input resistance : > 75 kΩ
Frequency:
Measuring range : 0 ... < 10 kHz
Low level : < 4,0 V
High level : > 6,0 V
Absolute limit values : ± 50 V
High-level pulse width : > 25 µs
Low-level pulse width : > 25 µs
Input resistance : > 44 kΩ

Voltage input for dimming:


Control of illumination intensity
Potential separation : 1 kV AC
Measuring range : 0 ... 24 / 36 / 48 / 72 / 110 V DC
Absolute limit values : ± 48 / 72 / 96 / 144 / 220 V DC
Input resistance : > 47 / 75 / 100 / 150 / 240 kΩ

Two binary status inputs:


Potential separation : 1 kV AC
Low level : < 6,0 V
High level : > 14,0 V
Input current : < 2,0 mA
Absolute limit values : ± 200 V
Typical debounce time : 100 ms

Seite 4 von 10 Copyright © messMa GmbH • All Rights Reserved • 17.05.2006


Reg.no. 6.1787.001. Operating Instruction AS-R

Outputs

Status relay:
Solid-state relay with normally open contact
Contact limit values : U < 150 V, I < 100 mA, RON < 35 Ω
Overvoltage protection
via parallel varistor : Typically 1 mA at 240 V

Indicator feedback unit


Recording of actual indicator positions by a feedback unit
Internal error response in the event of
a deviation of the actual indictator position
from the target indicator position: > (3,0 – 1,0) % from the scale end value

Interfaces to the output of the actual indicator positions:


No potential separation to the supply voltage
SUB D25 socket terminal strip
8-bit data width + handshake signal
Resolution : 1 bit corresponds to 1.5° indicator deflection
Signal level : HCMOS outputs
Output protective resistance
of the signal lines : 1 kΩ ± 10 %
Updating : When the actual position of an indicator changes
Handshake signal : Low-high edge
Data bit setup time : 750 ± 50 ns

Indication elements
Indication error : ± 1,0 % from the scale end value
Internal indicator : Dial opening angle = 240 °
Response time of indicator
f. 240° indicator deflextion: < 2,0 s
Two LED signals : Red/green/yellow, Ø = 3 mm
Scale illumination : Internal with LEDs, can be dimmed externally

Supply voltage:
24 V DC rated voltage : 16,8 ... 32,0 V DC
36 V DC rated voltage : 25,0 ... 50,0 V DC
48 ... 110 V DC rated volt. : 33,0 ... 143,0 V DC
Power consumption : < 3,2 W
Installation position : 0 ... 90°

Copyright © messMa GmbH • All Rights Reserved • 17.05.2006 Seite 5 von 10


Operating Instruction AS-R Reg.no. 6.1787.001.

4. Installation

Insert the AS-R analogue indicator at the front in the control panel
cutout.
Fasten it in place by screwing the fastening elements to the left and
right on the housing so that it is pressed in a fixed position against
the control panel.

Please note the specifications for the control panel:


• Max. thickness of 5 mm
• Cutout Ø = 101 +0.5 mm, 131 +0.5 mm

The following information can be found in Figures 1 and 4:


• Dimensions of the device
• Position of the installation elements and theconnection terminals

40
ø100,0 (ø130,0)

km/h
20 60

0 M 1
80
LED1 LED2

messMa

65,0 ø106,0 (ø136,0)


35,0 (30,0)

Figure 1 - Dimensions of the device

Seite 6 von 10 Copyright © messMa GmbH • All Rights Reserved • 17.05.2006


Reg.no. 6.1787.001. Operating Instruction AS-R

5. Connection

The connection configuration is shown in Figure 2.


Please note the following for the connection leads:
• Lead cross section of 0.5 to 1.5 mm²
• Free cable ends with crimped screw connection
• Twist rather than tin cable ends for spring connectors

Safety information:
Do not connect the device under voltage!
• Interrupt the voltage supply
• Connect the earthing connection marked
with the aid of the flat-type female
terminal to the rear of the device.

Dimming the scale


illumination: When using the external dimming input, it must be remembered that
setting the maximum dimming voltage results in the most intensive
scale illumination possible.
Owing to the potential separation of the dimming input from the
indicator supply voltage, an opposite behaviour can be achieved by
the incorrect connection of the input (increase in potential at
terminal 11).

Fuse: The indicator has a safety fuse (T 800 mA) accessible from the rear
for protection against supply overvoltage.

Note:
The indicator must be returned to the manufacturer if the fuse is
faulty.

Phoenix terminals

Terminal connection
1 +Supply voltage
2 - Supply voltage
3 not used
4 not used
5 +Status input 1
6 - Status input 1
7 +Status input 2
8 - Status input 2
9 Status relay (connection 1)
10 Status relay (connection 2)
11 - Voltage input for dimming
12 +Voltage input for dimming
13 - Internal indicator analogue/frequency input
14 +Internal indicator current/voltage input
15 +Internal indicator frequency input
16 not used
17 not used
18 not used

Figure 2 (Connection of Phoenix terminals)


Copyright © messMa GmbH • All Rights Reserved • 17.05.2006 Seite 7 von 10
Operating Instruction AS-R Reg.no. 6.1787.001.

Interface to the output of the actual indicator positions:

See Figure 3 for the configuration of the SUB D25..

Note:
• The logic outputs to the SUB D25 socket are not potentially
separated from the supply voltage
• The HCMOS logic outputs have protective series resistors of
1 kΩ± 10 %

SUB D25 indicator feedback unit

Terminal Connection
1 not used
2 GND
3 not used
4 not used
5 not used
6 not used
7 not used
8 GND
9 Handshake signal internal indicator
10 Daten bit 6 Innenzeiger
11 Daten bit 4 internal indicator
12 Daten bit 2 internal indicator
13 Daten bit 0 internal indicator
14 GND
15 GND
16 not used
17 not used
18 not used
19 not used
20 GND
21 GND
22 not used
23 not used
24 not used
25 not used

Figure 3 - Connection configuration (for SUB D25 feedback unit)


Seite 8 von 10 Copyright © messMa GmbH • All Rights Reserved • 17.05.2006
Reg.no. 6.1787.001. Operating Instruction AS-R

Connection diagram: Status input2 Status input1 not used


Counter input Supply voltage
- + - + - + - +
8 7 6 5 4 3 2 1

+ +
f
Supply voltage

External indicator
not used Internal indicator Dim m. scale illumin. Status relay
f+ U/I + - f+ U/I + - + -
18 17 16 15 14 13 12 11 10 9

I I

Dimming voltage Relay contact


+ U + U

f f
T800mA

9
1+ 10
2- -11
3+ +12
4- -13
5+ U/I+14
6- f+15
7+ -16
-
8- U/I+17
f+18
Zähler
Progr.

Figure 4 - Position of the installation elements and connection terminals

Copyright © messMa GmbH • All Rights Reserved • 17.05.2006 Seite 9 von 10


Operating Instruction AS-R Reg.no. 6.1787.001.

6. Conditions for use

Operating temperature : - 25 °C ... + 70 °C


Switch-on temperature : min. - 30 °C; max. + 80 °C
(Condition: achievement of the operating after
max. 1h)
Storage temperature : - 40 °C ... + 85 °C
IP rating : Front side IP 54, terminals IP 20
Vibration/shocks : Class A as per DIN EN 61373
Environmental conditions : Classes 5K2, 5B1, 5C1 as per DIN EN 60721-3-5

7. Housing design

Front dimensions : Ø = 106 mm, 136 mm


Control panel cutout : Ø = 101 +0,5 mm, 131 +0,5 mm
Installation depth : see dimensional diagram
Mass : approx. 800 g

8. Connection conditions

Interface to the output of the actual indicator positions:


SUB D25 socket terminal strip

Earthing connection:
Flat-type plug 6,3 x 0,8 mm
Accessories : Flat-type female termina 6,3 x 0,8 mm
(crimping cable connection of 2,5 mm²)
All other connections:
Phoenix terminals
Accessories(standard) : Phoenix plug components with threaded terminal ends
MC 1,5/8-STF-3,81 and MC 1,5/10-STF-3,81
(optional) : Phoenix spring connector
FK-MCP 1,5/8-STF-3,81 and MC 1,5/10-STF-3,81
Connectable
cross section : max. 1,5 mm²

9. Maintenance

The analogue indicators are maintenance-free.

CE - marking

• Railway applications, electro-magnetic compatibility EN 50121-1


• Railway applications, Electronic equipments used on rollingstock EN 50155
• Preventive fireproof on rail vehicles DIN 5510
• Rolling stock equipment EN 61373
• Ambient conditionst EN 60721-3-5
• Safety requirements for electrical equipment for measurement, control and laboratory use
EN 61010-1
• Degree of protection provided by enclosures EN 60529

Seite 10 von 10 Copyright © messMa GmbH • All Rights Reserved • 17.05.2006


messMa GmbH
D-39167 Irxleben • Am Stadtfeld 8
Tel.: (+49) 39204 / 886-0 • Fax: (+49) 39204 886 55
Internet:www.messma.de • e-mail:vertrieb@messma.de

Declaration of Conformity
AS-Q || AS-QZ || AS-R || AS-RZ

messMa declares that the product conforms


to the following specifications.

Any modification of the product requires our prior consent;


otherwise, this declaration will become null and void.

• Railway applications, electro-magnetic compatibility EN 50121-1

• Railway applications, Electronic equipments used on rollingstock


EN 50155

• Preventive fireproof on rail vehicles DIN 5510

• Safety requirements for electrical equipment for measurement,


control and laboratory use EN 61010-1

• Degree of protection provided by enclosures EN 60529

Datum: ................

Qual.-Sich.: ........
messMa GmbH
D-39167 Irxleben l Am Stadtfeld 8
Tel.: (+49) 39204 / 886-0 l Fax: (+49) 39204 886 55
Internet:www.messma.de l e-mail:vertrieb@messma.de

For attention:
Technical changes possible
The drawing, dimensions and other data are as far binding.

Certificate of quality
Material: The used materials are according to drawings,
lists of parts, DIN 57411 and international
standards.

Test of function: The test of function was carried out accor-


ding to test and quality classification and
the function was according to order.

Performance: The performance is according to the


technical documents and the delivery
contract as well as the international standards.

Guarantee: We guarantee for an unobjectionable


function and grant a period of guarantee
according to our delivery conditions.

device no. ________________ date _____________________

Inspector _________________ Guarantee of quality ________