Wiring Diagram

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

KONTRAKTOR

STANDARD
PANEL- LANTAI 1
(PANEL HAGER Shneider) inbow 12 POLE STOP
STOP AC SPLIT STK
KETERANGAN
DOWN LIGHT WALL MOUNT WATER
INSTALASI KONTAK HEATER 1,5 PK OUTDOOR
7W 7W 300 WATT 500 WATT 1500 WATT 300 WATT
MCB 3Ø MCB 1Ø NYM 3x2,5 mm2
25A/6kA 6A/6kA PVC HI (o) 3/4" LAMPU.1 56 8 BLOK AB 22
4A/6kA NYY 3x2,5 mm2 LAMPU.2 28 4
NYY 4x6 mm2

10A/6kA NYM 3x2,5 mm2 STK.1 2100 7


INCOME PLN

6A/6kA NYM 3x2,5 mm2 STK.2 300 1 JUDUL


4A/6kA NYY 3x2,5 mm2 STK.3 POMPA 300 1 BLOK AB TYPE ETHA 6 x 13 M
6A/6kA NYM 3x2,5 mm2 WH.1 500 1 CARPORT KIRI
10A/6kA NYM 3x2,5 mm2 AC.1 1500 1
1. Wering diagram
10A/6kA NYM 3x2,5 mm2 AC.2 1500 1
INCOME PLN NYY 4X4 + NYA 4mm ke LT.2 1561 2400 2500

3417 4228 5100

10,750
BC 6 mm2
PT. MPI

CP GUNUNG ANYAR II 6X13


PANEL- LANTAI 2
(PANEL HAGER Shneider) inbow STOP AC SPLIT STK
STOP WATER ATAP EXHAUST
DOWN LIGHT LED STRIP/TL HEATER
INSTALASI KONTAK 1,5 PK OUTDOOR
7W 12 W/M 300 WATT 500 WATT 1500 WATT 300 WATT 50 WATT
MCB 3Ø MCB 1Ø
MUHHAMAD WENDYSTA
NYM 3x2,5 mm2
20A/6kA 6A/6kA PVC HI (o) 3/4" LAMPU.1 61 7 1 2 Site Engineer
10A/6kA NYY 3x2,5 mm2 STK.4 2100 7
PT. GRIYO MAPAN SANTOSO
NYY 4x4 mm2

6A/6kA NYM 3x2,5 mm2 WH.2 1000 2


INCOME LT 1

10A/6kA NYM 3x2,5 mm2 AC.4 1500 1


4A/6kA NYY 3x2,5 mm2 STK.5 300 1
10A/6kA NYM 3x2,5 mm2 AC.5 1500 1
4A/6kA SPARE

1561 2400 2500

6461

SUBANDI
NYA 4 mm2 Site Supervisor
KE LT 1

PT. GRIYO MAPAN SANTOSO

SIGIT
Project Manager