Electrical Adjustment
5-1E. List of Adjustment Sheet
Minimum
No Name Parts Number Appearance Remarks
Order Qty

Contents of Sheet set is


1. X8 Adjustment Sheet Set SET430-000 1/ 1 set
below No.2 to No.6.

Count Sensor Adjustment 494-03


2. 100 pcs / 1 set
Sheet 3 (Same as J-Series)

D900101004
Replace MG Sheet after
3. MG Test Note (Same as 20 pcs/ 1 set
count 200 times.
1JL00J00015 for K4)

CIS ADJUSTMENT Remove surface film on the


4. SHEET D900101006 2 pcs / 1 set sheet before adjust CIS
(Sheet T) sensor.

CIS ADJUSTMENT Remove surface film on the


5. SHEET D900101005 2 pcs / 1 set sheet before adjust CIS
(Sheet R) sensor.

420-001A
Replace UV Sheet if face of
6. UV SHEET-25 (Same as for 1 pcs/ 1 set
Sheet dirty.
J-Series)
5. Electrical Adjustment
5-2A. Adjustment of Motor Drive
Related
Problem
Work Time 2 min.
Special Tools
Standard Value
(Unit: mm)

1. Select “Motor Drive” in the Maintenance


mode - Adjustment

2. Press mark.
Motor Speed SP 800 SP 1000 SP 1150
3. Stacker and Main Motor start automatically.

4. Adjustment completed when show “OK” for Main Result [OK] [OK] [OK]
all speed in LCD Display.
Feed Result [OK] [OK] [OK]
5. Electrical Adjustment
5-3A. Adjustment of CIS Sensor
Related
Problem CIS R Adjustment CIS T Adjustment
Work Time 2 min.
Special Tools Scale
Standard Value CIS R Sheet
(Unit: mm) CIS T Sheet

5. Clean CIS and IR Emitter Sensor.

6. Select CIS R sensor adjustment in the


Maintenance mode - Adjustment

7. Insert CIS R sheet (White sheet) on the CIS


sensor.

8. Press mark to adjust sensor.

9. When show “Adjustment OK” press

10. Select CIS T sensor adjustment in the


Maintenance mode - Adjustment

11. Insert CIS T sheet (Blue sheet) on the CIS


sensor.

12. Press mark.

13. When show “Adjustment OK” adjustment


completed.

Note:
Hold edge of CIS Sheet to prevent dirty of
surface.

Please replace CIS R/T Sheet when surface get


dirty or scratch. .
5. Electrical Adjustment
5-4A. Adjustment of Count Sensors
Related Problem
Work Time 1 min.
Special Tools
Standard Value
(Unit: mm)

1. Clean all count sensors.

2. Select Count sensor adjustment in the


Maintenance mode - Adjustment

3. Press mark to adjust sensor


automatically.

4. When show “Adjustment OK” adjustment


completed.
5. Electrical Adjustment
5-5A. Adjustment of UV/FL Sensors
Related Spiral Wrapping
Problem Abnormality
Work Time 1 min.
Special Tools Pic.1 Insert UV & FL Sheet as same position as below
Standard Value
UV & FL Sheet
(Unit: mm)

1. Enter to UV & FL Sensor.

2. Insert UV & FL Sheet on the UV Sensor.

3. Select UV & FL sensor adjustment in the


Maintenance mode - Adjustment

4. Press mark to adjust sensor


automatically.

Note:
Hold edge of Sheet to prevent dirty of surface.

Please replace Sheet when surface get dirty or


scratch. .
5. Electrical Adjustment
5-6C. Adjustment of MG Sensors
Related Spiral Wrapping
Problem Abnormality
Work Time 5 min.
Special Tools MG Sheet
Standard Value
(Unit: mm)

1. Remove Note Guide.

2. Enter the Maintenance Mode.

3. Select “Adjustment” - “MG & Ultrasonic” in Around 10mm


the Menu.

4. Put MG sheet more than 15 pcs on the


around 10mm from end of left side Hopper.

5. Touch mark (Yellow).

6. Put MG sheet again more than 15 pcs on


the around 10mm from end of right side
Hopper.
Around 10mm
7. Count MG Sheet L or R side until show
“OK” for all channels.

Note:
Please replace MG Sheet around 200 times
counted to keep accuracy of MG detection.
5. Electrical Adjustment
5-7B. Adjustment of Ultrasonic Sensors
Related Spiral Wrapping
Problem Abnormality
Work Time 5 min.
Special Tools MG Sheet
Standard Value
(Unit: mm)

Note:
Ultrasonic Sensor automatically adjusted when
adjust MG sensors.
Not necessary adjust Ultrasonic sensors again
when show OK in adjust Ultrasonic sensor
screen after adjust MG sensors.

1. Enter the Maintenance Mode.

2. Select “Adjustment” and “MG & Ultrasonic”


in the Menu.

3. Select Press to select page 2 to


adjust Ultrasonic Sensor.

4. Put MG Sheets more than 15 pcs on the


hopper.

5. Press to adjust Ultrasonic sensor.

6. Count MG sheets on the hopper until


indicate ‘OK.
5. Electrical Adjustment
5-8B. Adjustment of Hopper Sensor
Related
Problem
Work Time
Special Tools
Standard Value
(Unit: mm)

1. Clean Hopper sensors.

2. Select Hopper sensor adjustment in the


Maintenance mode - Adjustment

3. Put Sheet 3 on the Hopper.

Note:
If Sheet 3 not available, use bank note for
adjustment.

4. Press mark to adjust sensor


automatically.

5. When show “Adjustment OK” adjustment


completed.
5. Electrical Adjustment
5-9B. Adjustment of Stacker Sensor
Related
Problem
Work Time Pic.1
Special Tools
Standard Value
(Unit: mm)

1. Clean Stacker sensors.

2. Select Stacker sensor adjustment in the


Maintenance mode - Adjustment

3. Put Sheet 3 between 2nd and 3rd of Stacker


Wheel as Pic.1.

Note:
If Sheet 3 not available, use bank note for
adjustment.

4. Press mark to adjust sensor


automatically.

5. When show “Adjustment OK” adjustment


completed.
5. Electrical Adjustment
5-10B. Adjustment of Reject Sensor
Related Problem Pic.1
Work Time
Special Tools
Standard Value
(Unit: mm)

1. Clean Reject sensors.

2. Select Reject sensor adjustment in the Maintenance


mode - Adjustment

3. Put Sheet 3 in the Reject pocket as Pic.1.

Note:
If Sheet 3 not available, use bank note for
adjustment.

4. Press mark to adjust sensor.

5. When show “Adjustment OK” adjustment completed.

Caution:
If dirk position of notes could not detects correctly, set
darker printing area of bank notes as below and adjust
Stacker Sensor again.
5. Electrical Adjustment
5-11A. Adjustment of Encoder Sensor
Related
Problem
Work Time
Special Tools Sheet 3
Standard Value
(Unit: mm)

1. Select Encoder sensor adjustment in the


Maintenance mode - Adjustment

2. Put 15 pcs of Sheet 3 on the Hopper

3. Press mark to adjust sensor.

4. When show “Adjustment OK” adjustment


completed.

5. If show “NG”, count Sheet 3 until show


“OK”.
Please Setting SHEET on the Hopper
(Adjustment Sheet 3: 15 pcs)

Count CNT 0 pcs


Set Width 76mm
Set Encoder Distance
Avg. Encoder Width 0mm
Avg. Encoder Count 0 Hole