Druck PT Data Sheet
Druck PT Data Sheet
Druck PT Data Sheet
Data Sheet
Two ranges of silicon diaphragm gauge pressure transducers, one with a built-in reference tube and one with an integral ventilated cable. The reference tube type allows transducers to be remotely mounted via a connecting pressure tube to the active face of the diaphragm. A second pressure connection must be made from the ambient air pressure in the region of the fluid pressure being measured, to the reference tube (and hence the non-active face of the diaphragm) on the transducer. This allows a true gauge reading to be taken (ie. the pressure above the local ambient of the fluid being measured) by the remote transducer. The integral cable range has the reference, or non-active face of the transducer, vented to the atmosphere via a small pipe inside the cable and should be used when the transducer is mounted directly in contact with the fluid pressure being measured. Both ranges feature silicon diaphragms with a bridge of semiconductor strain gauges integrally diffused which is bonded onto a glass carrier and housed in a titanium body. Titanium is used because of its similar thermal characteristics to silicon and hence, reduced unwanted temperature effects. The transducers can be used with any fluid which will not attack titanium, silicon dioxide or glass. The reference tube, or cable ventilation, can only be connected to a dry, non-corrosive non-conducting gas such as dry air.
Features
q Excellent linearity and hysteresis q High overload capacity q Range of 14 transducers; 7 with integral cable and boot and 7 with PTFE cable and reference tube q 7 operating pressure ranges from 1 to 60bar q Good thermal stability; 0.5% total error band over full temperature range of 0-50C
Dimensions
11 20 28
21 18AF
Electrical connections 6 core shielded/vented cable Supply positive Red Supply negative White Output positive Ye l l o w Blue Output negative N/C to transducer body Screen Any other cores not connected
18AF
11
44
14
Electrical connections 4 core ptfe shielded cable Red Supply positive Blue Supply negative Ye l l o w Output positive Green Output negative Screen N/C to transducer body
232-5244
Technical specification
Max. overpressure _______________4 times rated pressure Max. pressure on reference connection (PDCR 820 types) _____________________2 bar Negative pressure __________________________to vacuum Burst pressure ________________> 10 times rated pressure Excitation voltage __________________________10Vdc 5mA Output voltage ______________________100mV (for 10V in) Common mode voltage________________+ 6.5V (typ) w.r.t. -Ve supply for 10V in Output impedance ___________________________2K nom. Minimum load impedance ___100k for rated performance Resolution _____________________________________Infinite Combined non-linearity, hysteresis and repeatability_________________0.1% B.S.L. (best straight line) Zero offset and span setting _________________3mV max. Operating temp. range __________________-20C to +80C Temperature effects _______0.5% total error 0C to +50C Electrical connections __________________1m integral lead 6 core 810 series 4 core 820 series Pressure connections _________1/4 in BSP 60 internal core
Panel mounting digital pressure indicator DPI 260 (RS stock no. 646-763)
The digital pressure indicator will measure and indicate pressure to an accuracy of 0.1% full scale. The indicator utilises the PDCR 810 or 820 series pressure transducers. The compact, self contained, unit incorporates an extremely stable polarising supply, signal conditioning and amplifier system which does not degrade the transducer specification. The indicator is housed in a rugged ABS case designed to fit a DIN (92 x 45mm) panel cut-out.
Features
q q q q q q Excellent linearity and hysteresis 7.5mm seven segment display Front panel zero and span adjustment Self contained strain gauge indicator Field ranging/scaling by internal switches Analogue output: 0-2V.
REMOTE TRANSDUCER PRESSURE SOURCE L.E.D. DISPLAY AMPLIFIER SCALING UNIT A.D.C.
19.999
PSI
POWER SUPPLIES
LINEARISATION UNIT
POWER SUPPLIES
TRANSFORMER
232-5244
Specification
Readout
19999.
Display
7.5mm seven segment L.E.D.
Power supplies
110V or 240V, 50-400Hz at 3VA max. Link selectable.
Display overload
Settable anywhere between 1999 and 19999 to give 1 and flashing 0000.
Dimensions
96mm (wide) x 48mm (high) x 175mm (deep).
Resolution
0.005% F.S. maximum.
Weight
500gms. nominal.
Response
333msec to full scale on digital display and BCD output.
Position effect
Negligible.
Excitation voltages
5 or 10 Volts into 350 ohm bridge minimum.
Zero suppression/elevation
Capable of 19999 switch settable internally.
Electrical connection
Connector supplied with remote transducer and 1 metre of cable. Pin 1 Supply positive Pin 2 Output positive Pin 3 Output negative Pin 4 Supply negative Pin 5 Screen Pin 6 Sense
Temperature performance
Sensitivity temperature coefficient <0.005% of reading/C. Zero offset temperature coefficient <0.003% F.S./C. (ref. to 50mV input - 5V common mode) Zero suppression temperature coefficient 0.005% of reading/C.
Accuracy
Combined non-linearity, hysteresis and repeatability. 0.1% F.S. for 70mbar to 60bar 0.15% F.S. for 60bar to 700bar
18
52
22 A/F
30
BASEEFA Apparatus Certificate Ex97D2058 Approval category: EEx ia IIC T4 zone 0 Two-wire, 4-20 mA pressure sensors designed for continuous monitoring in hazardous areas such as gas/petrochemical and process control environments.
q q q q q q q q
+/-0.15% typical accuracy Zero and span adjustment of +/-5% Absolute and Gauge referenced pressure ranges 4 to 20mA output proportional to applied pressure Compatible with hostile media All stainless steel construction Electron beam welded wetted parts Built-in protection from: power supply fluctuations; reverse polarity; voltage spike, RFI q Intrinsically safe, should be used with a galvanic isolation barrier such as RS stock no. 259-6682. q IP65 rated.
232-5244
Technical specification
Over press.____________1 bar for 100 and 250mbar ranges Supply volt. ____________9 to 30V d.c. (pin 1 +ve, pin 2 -ve) Voltage spike prot.__________withstand 600V to ENV 50142 Zero offset/span setting _________________+/-0.5% / +/-5% Long term stabil. ______________________________+/- 0.2% Combined non-linearity______+/-0.15% typ. +/- 0.25% max. hysteresis and repeat. Operating temp. ________________________-20C to +80C Weight__________________________________________200g Press. connection _____________G 1/4 female (BSP Parallel) Elect. connection ___DIN 43650 plug with fee mating socket.
49
38
78.5
22. A.F
11
BASEEFA Apparatus Certificate No.: Ex892251x Approval category: EEx ia IIC T4 Two-wire, 4-20 mA pressure sensors designed for continuous monitoring in hazardous areas such as gas/petrochemical and process control environments. q Gauge style pressure measurement only q Robust stainless steel body with encapsulated electronic and silicon technology sensing element. q Suitable for use in Zone O Gas Group IIC, Temperature Class T4 q G 1/4 BSP pressure connection and DIN 43650 electrical connector (supplied) q Supplied with instruction leaflet with product and copy certificates available on request. q Should be used with a galvanic isolation barrier such as stock number RS 259 6682 q IP65 rated q Available with RS Servicepoint Calibration
Explanation
Absolute pressure is pressure measured with reference to vacuum pressure. An example of absolute pressure measurement is barometric measurement of atmospheric pressure. Gauge pressure is pressure measured with reference to atmospheric pressure. It can be viewed as a form of differential pressure. An example of gauge pressure measurement is measurement of tyre pressure.
Technical specification
Maximum overpressure 250m bar _______________________________________2 bar 1.6 bar to 25 bar __________________________3 x pressure 60 bar to 400 bar __________________________2 x pressure Supply voltage ______________________________9-30V d.c. Output current ________________________________4-20mA Combined non-linearity hysteresis and repeatability _________________10.15% FS Zero offset and span _________________5% site adjustable Long term stability _________________________0.1%, FS p/a Operating temp. ________________________-20C to +80C Process media temp. range _____________-30C to +120C Temperature effects ________________0.5% 9-10 to +50C RFI protection ___Conforms with IT 8839 (10kHZ to 500Mhz)
Range
Uncalibrated RS Servicepoint Calibrated
250m bar 1.6 bar 4 bar 10 bar 25 bar 60 bar 160 bar 400 bar
P.T.B. Cert. No Ex-94.C.2326 Approval category EExia 11a, 11b, 11c The unit is designed to power both 2-wire standard and SMART 420A transmitters in the hazardous area, transferring the output signal to the safe area. KFD2-STC1-Ex1 - Smart Transmitter/Power Supply Single channel Input EEx ia IIC Class 1, Div1, Groups A-G d.c. 24V Nominal power supply SMART compatible EMC in acc. with NAMUR NE 21 As an output signal, 20mA are available, digital information is generated by a processing system, field device or hand-held terminal and bi-directionally transferred by the barrier. This allows the operator to interrogate and reprogram the transmitter from the safe area, using non-certified communication equipment. These operations can be carried out in the hazardous area using suitably certified equipment. Hand-held terminals can be connected. In order to interface a hand-held terminal as easily as possible, these barriers come equipped with KF-STP-BU and KF-STP-GN terminals containing access holes for test probes.
Connections
Figure 4
Input EEx ia IIC Hazardous area Zone O
16.5V
PRESSURE TRANSMITTER
3-
1+
11 +
9+ 10(L-)
7 (L+) 8(L-)
Front View
1 4
2 5
3 6
7 10
8 11
9 12
Safe Area
Technical specification
Pressure ranges ____________________200mbar differential 2bar gauge 2bar absolute 20bar gauge Overpressure ______________Display flashes at 110% x FS* Safe to 2 x FS Accuracy: combined non-linearity,______________________+/-0.1% FS hysteresis and repeatability Temperature effects: Span ______________+/- 0.02% rdg/C Zero 1 bar (absolute only)_______________+/-0.5% FS/C >1bar (absolute only) _____________________+/0.2% FS/C Pressure connections ____________G1/8 and 6mm OD hose Pressure units _______Mpa, kPa, Pa, mbar, bar, psi, mmHg, Mhg, inHg, hPa, kgf/cm2, mH2O H2O @ 20C, H2O @ 4C * FS = Full scale
BASEEFA Certificate no: Ex 98E 2332 A compact and rugged range of digital pressure indicators designed for all pressure measurement and approved for use in hazardous areas. q Instrinsically Safe (EEx ia IIC T4) q 16 pressure units q Leak testing q High accuracy (0.1% full scale) q Ambient temperature measurement q Zero/display tare q Peak value hold q Alarm setting q Auto-off q Transient filter q Hinged fold away stand for bench use or hanging q Supplied with 3 x AA Alkaline cells and carry case with belt loop
Technical specification
Pressure ranges ____________________200mbar differential 2 bar gauge 2 bar absolute 20 bar gauge Overpressure __Display flashes at 110% x FS safe to 2 x FS* Accuracy: Combined non-linearity _______________________0.1% FS hysteresis and repeatability Temperature effects: span ________________0.02% rdg/C Zero < 1 bar (absolute only) _______________0.05% FS/C 1 bar (absolute only)______________________0.02% FS/C Pressure connections ____________G1/8 and 6mm OD hose Pressure units _____________MPa, kPa, Pa, mar, psi, mmHg, Mhg, inHg, hPa, kgf/cm2, mH2 O inH20 @ 20, inH2O @ 4C * FS = Full scale
Range
Uncalibrated Differential DPI705-200mbar gauge DPI705-2bar absolute DPI705-2bar gauge DPI705-20bar 312-0494 312-0517 312-0539 312-0523 Calibrated 315-9010 315-9026 316-1215 315-9032
Range
DPI705 I/S 200 mbar DPI705 I/S bar gauge DPI705 I/S 2 bar absolute DPI705 I/S 20 bar Uncalibrated 339-0378 339-0390 339-0384 339-0407 Calibrated 339-4106 339-4112 339-4128
Technical specification
BASEEFA Certificate No: Ex 99E2002X q A rugged, highly versatile, portable pressure calibrator approved for use in hazardous areas-Instrinsically safe (EEx ia IIC T4). q Provides a task driven user interface which facilitates easy setup of calibration, switch testing, leak testing, 4 to 20mA simulation, relief valve testing, data logging and ambient temperature recording modes. q Precision accuracy (0.025% full scale) q Built-in pressure/vacuum pump (-850mbar to +20 bar) q Cyrrent and voltage measurement q Pressure and current displayed simultaneously q Data storage and RS 232 interface Pressure range ________________________________0-2 bar 0-10 bar 0-20 bar Pressure media ______compatible with most common fluids Display ______________________5 digit, 13.6mm LCD digits with additional 16 text characters Resolution _________________________0.005% FS maximum Accuracy _________________________________0.075% FS Electrical ranges ____________________________0-50V d.c. 0-55mA Electrical outputs ___________24V nominal fixed, 25mA max Loop check ___________12mA nominal fixed, source or sink Operating temp. range __________________-10C to +50C Calibrated temp. range ____________________0C to +40C Pressure connection _________________________G18 female Environmental sealing _____________________________IP65 Batteries ___________________4 x size D cells zinc carbide
Technical specification
Pressure
Range 0-2 bar 0-7 bar 0-20 bar Inputs Voltage Current Temp. Overpressure 4 bar 14 bar 35 bar Range +/-50Vd.c. +/- 55mA -10 to 40C 0 to 24 mA Accuracy +/-0.05% rdg +/-0.004% FS +/-0.05% rdg +/-0.004% FS +/-1 C +/-0.1% +/- 5% +/-0.05% rdg +/- 0.1% FS 0.001mA Resolution 100 V 0.001mA 0.1C G 1/8 (female) Pressure port
Range
2 bar 10 bar 20 bar Uncalibrated 215-0826 215-0832 213-0844 Calibrated 215-7158 215-7142 215-7120
Outputs
Current
Range
Type DPI10 I/S 2bar DPI610 I/S 7bar DPI610 I/S 20bar 339-0413 339-0429 339-0435
RS Components shall not be liable for any liability or loss of any nature (howsoever caused and whether or not due to RS Components negligence) which may result from the use of any information provided in RS technical literature.