Linear Light Sensor LLS05-A

Linear Light Sensor

TYPE:LLS05-A

SENBA OPTICAL ELECTRONIC CO.,LTD.

Copyright © V1.0 2005-7 Page 1 of 7 SENBA OPTICAL ELECTRONIC CO.,LTD.


Linear Light Sensor LLS05-A

LLS05-A Replacement of CdS


RoHS Compliant / Pb-free / Cd-free
Linear Output Type Light Sensor
Production Specification

TYPICAL APPLICATIONS Outline Dimensions


·Replacement of Photoresistor (CdS).
·Control of backlight brightness for LCD Monitors,TV sets,
PDA ,Cameras and Mobile Phones.
·Switch for lighting equipments and Toys.
·Testing for daylight.

FEATURES
·Linear output conforming to illuminance.
·Built-in optical filter for spectral response similar
to that of the human eye.
·High Gain Photocurrent Amplifiers IC :
·Temperature Stable. 2 1 :
·Low dark current and Low working Lux.
·RoHS Compliant / Pb-free / Cd-free.

Internal Connection Diagram

FUNCTIONAL PIN DESCRIPTION

Item Description
VDD Positive Terminal
VOUT Negative Terminal

MAXIMUM RATINGS (Ta= 25°C)

Characteristics Symbol Rating Unit


Supply voltage VDD -0.5 to 7 V
Output voltage VOUT ≤ VDD V
Permissible power dissipation P 70 mW
Operating temperature range Topr -30 to 85 °C
Storage temperature range Tstg -40 to 100 °C
Soldering temperature range (10 s) Tsol 260 °C

Copyright © V1.0 2005-7 Page 2 of 7 SENBA OPTICAL ELECTRONIC CO.,LTD.


Linear Light Sensor LLS05-A
ELECTRICAL AND OPTICAL CHARACTERISTICS (Ta= 25°C)

Parameter Symbol Test Conditions Min Type Max Unit


Peak Spectral Response λPR 550 nm
Photocurrent (1) IL(1) VCC=5V, EV=5Lux 2.0 2.5 2.8 uA
Photocurrent (2) IL(2) VCC=5V, EV=10Lux 5.40 8.23 8.70 uA
Photocurrent (3) IL(3) VCC=5V, EV=100Lux 91.0 114.0 158.0 uA
Dark Current IDD(DARK) VCC=5V, Ev=0Lux 10 nA
Linear Response Range Ev 1-200 Lux
Switching Rise time tr 8.5
Vcc=5V, Rss=10kΩ ms
Time Fall time tf 8.5
Note: Output capacitance has an effect on switch time.
The white LED is regarded as light source.
TEST SCHEMATIC CIRCUITS

Photocurrent=Vout/Rss
*Rss is recommended to use high stable resistor.

Figure 1 - Photocurrent Measurement Circuit

Figure 2 - Measuring Method for Switching Time

Copyright © V1.0 2005-7 Page 3 of 7 SENBA OPTICAL ELECTRONIC CO.,LTD.


Linear Light Sensor LLS05-A
ELECTRICAL AND OPTICAL CHARACTERISTIC CURVES

Figure 3 - Spectral Response Curves

Figure 4 – Photocurrent vs. Illuminance Figure 5 – Dark Current vs. Ambient Temperature

Copyright © V1.0 2005-7 Page 4 of 7 SENBA OPTICAL ELECTRONIC CO.,LTD.


Linear Light Sensor LLS05-A
APPLICATION EXAMPLES

Automatic Night Light Figure 6.


This circuit show the LLS05-A in an Automatic
Night Light . The Lamp current is switched by a
sensitive gate SCR. The Igate (Type) of the
SCR(Silicon Controlled Rectifier) should be less than
10uA. When the light is above threshold, current
flows between the VDD and VOUT pins of the IC which
diverts current away from the gate of the SCR. The
light switching threshold can be adjusted by
choosing different values for R2 and R3.

Figure 6

Relay Drivers Figure 7.


The relay coil is energised when the
light < Slux(threshold). The Slux (threshold)
is set by R1. For battery operated circuits,
the hfe of TR2 should be high to allow a high
value for R3. The hfe of TR1 should be high
so that a low base current will be able to pull
R3 down.

Figure 7

Interface Circuit Examples Figure 8 & Figure 9


Figure8.This circuit uses a comparator (or Amp) to provide a level switching interface for the
LLS05-A. Out will be high when the voltage at VOUT < 0.1*VDD.

Figure 8 Figure 9
Figure 9 as Figure 8 except that out will be high when the voltage VOUT > 0.1*VDD

Copyright © V1.0 2005-7 Page 5 of 7 SENBA OPTICAL ELECTRONIC CO.,LTD.


Linear Light Sensor LLS05-A
CAUTIONS FOR USE

♦ Do not use the sensors under conditions that exceed the range of its specifications.
♦ Application circuit diagrams and circuit constants contained herein are shown as examples of
standard use and operation. Please pay careful attention to the peripheral conditions when
designing circuits and deciding upon circuit constants in the set.
♦ CMOS IC is contained, so static electricity should be avoided .
♦ Be sure to perform soldering at values within the maximum ratings. Take care so that no
external force is applied to the lead during and immediately after soldering. Do not perform
reflow soldering.
♦ The product is compliant with ECC RoHS.
♦ The photocurrent will be influenced if the dirty or destroy on the surface.
♦ The sensors are small, transparent, plastic packages. They are sensitive to moisture and come
in sealed, moisture proof packages.
♦ Small packing for 1000PCS, Big packing for 10000PCS.

Copyright © V1.0 2005-7 Page 6 of 7 SENBA OPTICAL ELECTRONIC CO.,LTD.


Linear Light Sensor LLS05-A

SALES OFFICE
SHENZHEN SENBA OPTICAL & ELECTRONIC CO., LTD.
Add: No.3 building,huafeng Industry Area, 39 District ,BaoAn ,ShenZhen City,China
Web: www.sbcds.com.cn
E-mail: sbcds@public.szptt.net.cn
Tel: 86-755-27895411, 27896456
Fax:86-755-27897072, 27895396

Copyright © V1.0 2005-7 Page 7 of 7 SENBA OPTICAL ELECTRONIC CO.,LTD.