Fuel Optimized
Description
The KTA38-Series benefits from years of Cooling System – Gear driven centrifugal water
technical development and improvement to pump. Large volume water passages provide
bring customers an innovative and future proof even flow of coolant around cylinder liners,
diesel engine that keeps pace with ever valves, and injectors. Bypass thermostats
changing generator set requirements. regulate coolant temperature. Spin-on corrosion
resistors check rust and corrosion, control acidity
Recognized globally for its performance under
and remove Impurities.
even the most severe climatic conditions, the
KTA38-Series is widely acknowledged as the Cylinder Block – Alloy cast iron with removable
most robust and cost-effective diesel engine in wet liners. Cross bolt support to main bearing
its power range for the generator set market. cap provides extra strength and stability.
cummins.com
©2023 Cummins Inc. | KTA38-G5 (02/23)
1500 rpm (50 Hz Ratings)
Gross engine output Net engine output Typical generator set output
Standby Prime Base Standby Prime Base Standby (ESP) Prime (PRP) Base (COP)
kWm/BHP kWm/BHP kWe kVA kWe kVA kWe kVA
970/1300 880/1180 656/880 938/1258 858/1150 634/850 887 1109 811 1014 600 750
Fuel Consumption 1500 (50 Hz) Fuel Consumption 1800 (60 Hz)
US US
% kWm BHP L/hr % kWm BHP L/hr
Gal./hr Gal./hr
Standby Power Standby Power
100 970 1300 228 60.3 100 - - - -
Prime Power Prime Power
100 880 1180 209 55.1 100 - - - -
75 660 885 161 42.5 75 - - - -
50 440 590 113 29.9 50 - - - -
25 220 295 65 17.3 25 - - - -
Continuous Power Continuous Power
100 656 880 158 41.7 100 - - - -
cummins.com
©2023 Cummins Inc. | KTA38-G5 (02/23)
*Drawing for illustration purposes only.
Ratings Definitions
Emergency Standby Limited-Time Running Prime Power (PRP): Base Load (Continuous)
Power (ESP): Power (LTP): Power (COP):
Applicable for supplying power Applicable for supplying power Applicable for supplying power Applicable for supplying power
continuously to varying to a constant electrical load for to varying electrical load for continuously to a constant load
electrical loads for the duration limited hours. Limited-Time unlimited hours. Prime Power up to the full output rating for
of power interruption of a Running Power (LTP) is in (PRP) is in accordance with ISO unlimited hours. No sustained
reliable utility accordance with ISO 8528. 8528. Ten percent overload overload capability is available
source. Emergency Standby capability is available in for this rating. Consult
Power (ESP) is in accordance accordance with ISO 3046-1. authorized distributor for rating.
with ISO 8528 and ISO 3046-1, Data shown above represents (Equivalent to Continuous
obtained and corrected in gross engine performance and Power in accordance with ISO
accordance with ISO 15550). capabilities as per ISO 3046-1, 8528 and ISO 3046-1, obtained
obtained and corrected in and corrected in accordance
accordance with ISO 15550. with ISO 15550).
©2023 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and “Our energy working for you.” are trademarks of
Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice.
KTA38-G5 PD00000068 (02/23)