Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

The IMZ Implant System: IMZ Original 3.3 & 4.0 Non-Hex Flat-Top

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

The IMZ Implant System

T
IMZ - Original

he IMZ Implant System was developed in Germany by Dr. Axel Kirsch in the early 1970s. It is the only major implant system using a shock absorbing intermobile element designed to simulate the periodontal ligament.

s IMZ Original 3.3 & 4.0 non-hex flat-top s IMZ Original The original IMZ implant was manufactured in two diameters 3.3mm and 4.0mm. The internal thread of the 3.3mm implant is 2.4mm and the 4.0mm implant has a 3.0mm thread. The external implant body is either titanium plasma sprayed or HA coated with hydroxalappetite. The IMZ implant body is no longer sold, however, IMZ restorative components, such as the complete abutment, UMA, etc., can still be purchased from Attachments International. Implants s IMZ Original 3.3 & 4.0 non-hex flat-top Restoratively Compatible To none

Indications and Quantities of Implants recommended:


Single Tooth Replacement One implant is required. Use the IMZ Hex Head for this type restoration. Not recommended with the original IMZ 3.3 or 4.0. Bridge Reconstructions Recommended for 1 implant attached to an abutment, or for 2 or more free standing implants using a tissue extension. Fixed / Detachable Reconstructions Recommended for 5 or more implants on a fully edentulous arch. Bar Type Overdentures Recommended for 2 or more implants using a UMA, complete abutment or IME tissue extension, or for an implant attached to a natural abutment. Stud Type Overdentures Requires at least 1 implant. Whenever possible more implants should be used.

All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

Terminology of Components

Restorative Components:
The restorative components are the elements used to fabricate a restoration that will be connected to the implant(s). The restoration may also be attached to an intermediate component called a tissue extension (UMA or IME) or abutment which in turn is connected to the implant(s).

Implant Body:
The implant body is placed into the bone for approximately 4-6 months to allow for osseointegration. The implants should not be loaded prior to osseointegration.

IMZ - Original

Tissue Extension:
The TE (Tissue Extension) also referred to as the Complete Abutment, is the intermediate connector between the implant and the restoration, it may extend above the tissue. In some instances, a TE extension is subgingival, to provide a more esthetic restoration.

IMZ

Complete Abutment

Implant Standardization:
The UMA tissue extension was developed to standardize the many different implant companies' components and instruments for a more economically controlled inventory and for simplicity of restorative procedures. Its tapered/hexagon fitting surface is identical, regardless of the size or type of implant employed, while its screw-in base is implant specific.
UMA

Compatibility:
Implants s IMZ Original 3.3 & 4.0 non-hex flat-top Restoratively Compatible To none

All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

IMZ Non-Hex 3.3 & 4.0 Compatible


IMPRESSION COPINGS
Impression copings are used to take an impression of the implant body or the tissue extension, such as the UMA, Complete abutment, titanium IME, or plastic IME. The Impression Copings which fit the implant bodies are made of titanium and transfer the thread timing. The new style

Impression Copings Analogs

IME/UMA impression coping is made of titanium and is more accurate than the old style plastic impression coping. For the IMZ-Hex Head implant, refer to the Branemark compatible section. When the UMA insert is used as a tissue extension, the standard line of UMA components is indicated.

3.3

SD Small Implant Diameter IMZ 3.3 MD Medium Implant Diameter IMZ 4.0

SD
3.3
Order #

MD
4.0
Order #

Description

Impression CopingsTo Fit Implant


Impression Coping for IMZ (A) 56-300080 56-400080

Impression CopingsTo Fit UMA / IME or Complete Abutments


IME / UMA Impression Coping Tapered 3.3 or 4.0 (B) 56-000080 56-000080

ANALOGS
Analogs are used for the fabrication of a master model. They are replicas of the implant body or the IME or Complete abutment tissue extension. The new IME impression technique requires only one analog.

SD
3.3
Order # 56-300015 56-000015

MD
4.0
Order # 56-400015 56-000015

Description IMZ Implant Body Analog, Brass (A) IME Analog, Brass (B)

All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

IMZ Non-Hex 3.3 & 4.0 Compatible


HEALING CAPS
Healing caps are used to maintain access through tissue during healing phase. They are available in various heights to accommodate tissue depth. Two types of titanium healing

UMA Abutment UMA Cylinder, Screw & Plug (CSP)

caps are available, both requiring the .050" hex driver: 1) fits directly to the implant, 2) fits on the IME or the UMA.

4.0

SD Small Implant Diameter IMZ 3.3 MD Medium Implant Diameter IMZ 4.0

SD
3.3
Dimensions H=2.0mm H=4.0mm H=6.0mm H=2.0mm H=4.0mm H=6.0mm Order # 56-302120 56-302140 56-302160 11-002120 11-002140 11-002160 11-000007

MD
4.0
Order # 56-402120 56-402140 56-402160 11-002120 11-002140 11-002160 11-000007

Description

Healing CapsTo Fit Implant


Implant Healing Cap (A) Implant Healing Cap Implant Healing Cap

Healing CapsTo Fit IME / UMA


IME, UMA Healing Cap IME, UMA Healing Cap IME, UMA Healing Cap TOOLS DDS Hex Driver .505"

COMPLETE ABUTMENT (TISSUE EXTENSION) NEW STYLE


The complete titanium abutments are extensions to fit from the implant through the tissue, without the TIE. The Complete Abutment combines the TIE and the IME in one unit, like the UMA. The UMA healing caps will also fit the IME or Complete abutment. When the UMA insert is used in place of the IME or the Complete Abutment, then the standard line of UMA components are indicated.

SD
3.3
Dimensions OH=2.5mm OH=3.5mm OH=2.0mm OH=3.0mm OH=5.0mm Order # 56-318330 56-318335

MD
4.0
Order # 56-418320 56-418330 56-418350 58-100190 58-100170 56-000080 56-000015

Description Complete Abutment 3.3 Complete Abutment 3.3 Complete Abutment 4.0 Complete Abutment 4.0 Complete Abutment 4.0 TOOLS LT / RA Handle LT / RA Complete Abutment Tip Impression Coping for IME or Complete Abutment Brass Analog for IME or Complete Abutment

OH = Overall Height
All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

IMZ Non-Hex 3.3 & 4.0 Compatible


UMA ABUTMENT (TISSUE EXTENSION)
The UMA titanium abutments are extensions which fit from the implant through the tissue, without the TIE. The UMA is the most widely used universal abutment utilizing a hex and a taper. The UMA is available for most commonly available

UMA Abutments UMA, Cylinder, Screw & Plug (CSP)

implant systems. The standard UMA components are indicated when the UMA insert is used in place of the IME or the complete abutment. For details, refer to the UMA section.

3.3

4.0

SD Small Implant Diameter IMZ 3.3 MD Medium Implant Diameter IMZ 4.0

SD
3.3
Dimensions 0.5mm 1.0mm 2.0mm 3.0mm 4.0mm 5.0mm 6.0mm 7.0mm Order # 11-001320 11-001330 11-001340 11-001350 11-001360 11-001370

MD
4.0
Order # 11-001405 11-001410 11-001420 11-001430 11-001440 11-001450 11-001460 11-001470

Description UMA Abutment UMA Abutment UMA Abutment UMA Abutment UMA Abutment UMA Abutment UMA Abutment UMA Abutment TOOLS: UMA Abutment Driver UMA Impression Coping, Tapered Non-Hex UMA Impression Coping Hex w/ .050" Hex Guide Pin UMA Brass Analog

see UMA section 11-000080 11-000090 11-000015

UMA, CYLINDER, SCREW & PLUG (CSP)


The UMA, CSP consists of a machined plastic cylinder hex or non-hex (bridge) type, a hex or slot screw, and an occlusal plug to seal the opening of the occlusal access hole. The hex cylinders are used for single or telescopic abutments, while the non-hex cylinders are used for bridges or overdenture bars.

Description UMA, CSP Hex Cyl & Hex .050" Screw & Plug (A) UMA, CSP Hex Cyl & Slot Screw & Plug (B) UMA, CSP Non-Hex Cyl & Hex .050" Screw & Plug (C) UMA, CSP Non-Hex Cyl & Slot Screw & Plug (D) UMA, Short Cylinder Only, Red (E) TOOLS: UMA, Reamer Gold Handle UMA, Lapping Tool and Guide Pin Note: For Slot Screws do not exceed 10 N/cm of torque.
All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

Order # 11-000202 11-000201 11-000252 11-000251 11-000270 11-000150 11-000155

IMZ Non-Hex 3.3 & 4.0 Compatible


TITANIUM & PLASTIC POSTS
The direct titanium abutment posts screw into the implant body and are indicated for Bridge Restorations only. They may be secured with Teflon tape, Omni-Lite or OMNI-Bond

Titanium Posts Plastic Posts Ti-Blocs

(see misc. implant section). The tapered posts can be altered like a preparation. Fabricate a soft tissue model whenever preparations are made in the laboratory.

SD Small Implant Diameter IMZ 3.3 MD Medium Implant Diameter IMZ 4.0

SD
3.3
Order # 56-301200 56-301100

MD
4.0
Order # 56-401200 56-401100

Description Direct Titanium Posts (A) Direct Plastic Posts (B) USE WITH: Impression Coping Implant Body Analog

56-300080 56-300015

56-400080 56-400015

TI-BLOC
The titanium bloc screws into the implant body and may be secured with Teflon tape, Omni-Lite or OMNI-Bond. The Ti-Bloc requires more preparation as it is a true cylindrical bloc. However, the Ti-Bloc can be prepared like a posterior prep, thereby increasing the esthetics and comfort. It can also be prepared to correct for divergency.

SD
3.3
Dimensions =4.0mm =8.0mm =5.0mm =8.0mm Order # 56-301210 56-301220

MD
4.0
Order # 56-401210 56-401220

Description Ti-Bloc 3.3 small (A) Ti-Bloc 3.3 medium Ti-Bloc 4.0 small (B) Ti-Bloc 4.0 medium USE WITH: Impression Coping Implant Body Analog

56-300080 56-300015

56-400080 56-400015

All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

IMZ Non-Hex 3.3 & 4.0 Compatible


PLASTIC CYLINDERS TO FIT IME & COMPLETE ABUTMENT
The plastic cylinders will fit the IME as well as the Complete Abutment. We recommend the castable plastic cylinders as there will be no coefficiency problem or breakage around the cylinder. The cylinders use the short screws that are available with a slot or with a .050" hex head.

Plastic Cylinders Screws & Guide Pins

The CSP abbreviation means that it includes the long gray castable plastic cylinder, a screw, and an occlusal plug. DO NOT CAST IMPLANT RESTORATIONS IN BASE ALLOY (NON-PRECIOUS).

SD Small Implant Diameter IMZ 3.3 MD Medium Implant Diameter IMZ 4.0

SD
3.3
Order #

MD
4.0
Order #

Description

CSP (Cylinder, Screw & Plug)


CSP, Cylinder, Slot Screw and Plug (A) CSP, Cylinder, .050" Hex Screw and Plug (B) PARTS Plastic Cylinder, Long for 3.3 or 4.0 (C) Plastic Cylinder, Short for 3.3 or 4.0 (D) Slot Screw Only Hex .050" Screw Only TOOLS UMA, Reamer Gold Handle UMA, Lapping Tool and Guide Pin 56-300251 56-300252 56-000250 56-000270 56-300051 56-300052 56-400251 56-400252 56-000250 56-000270 56-400051 56-400052 11-000150 11-000155

SCREWS & GUIDE PINS


The titanium screws and titanium guide pins are used to fasten the restoration to the abutments.

SD
3.3
Order #

MD
4.0
Order #

Description

Screws (A)
Slot Screw Hex .050" Screw 56-300051 56-300052 56-400051 56-400052

Guide Pins (B)


Guide Pins .050" Hex 11-000062 11-000062

Note: For Slot Screws do not exceed 10 N/cm of torque.

All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

IMZ Non-Hex 3.3 & 4.0 Compatible


OVERDENTURE STUD TYPE ATTACHMENTS
Two overdenture attachments are commonly used to directly screw in to the implant the Dalla Bona and the ORS, O-Ring system. Both male elements are made of titanium and are attached directly to the implant body. The Dalla Bona includes 1 male, 1 adjustable female, 1 spacer and

Overdenture Stud Type Attachments

1 brass analog. The ORS includes 1 male, 1 retainer ring, 3 white and 3 red O-Rings and a brass analog. The retention of the Dalla Bona female is adjustable with the activating/deactivating tool.

SD Small Implant Diameter IMZ 3.3 MD Medium Implant Diameter IMZ 4.0

SD
3.3
Dimensions H=1mm H=2mm H=3mm H=4mm H=5mm H=6mm H=7mm H=1mm H=2mm H=3mm H=4mm H=5mm H=6mm H=7mm Order # 56-343010 56-343020 56-343030 56-343040 56-343050 56-343060 56-343070 56-344010 56-344020 56-344030 56-344040 56-344050 56-344060 56-344070

MD
4.0
Order # 56-443010 56-443020 56-443030 56-443040 56-443050 56-443060 56-443070 56-444010 56-444020 56-444030 56-444040 56-444050 56-444060 56-444070

Description

Dalla Bona System (A)


Dalla Bona, complete Dalla Bona, complete Dalla Bona, complete Dalla Bona, complete Dalla Bona, complete Dalla Bona, complete Dalla Bona, complete

ORS, O-Ring System (B)


ORS, complete ORS, complete ORS, complete ORS, complete ORS, complete ORS, complete ORS, complete PARTS Dalla Bona, Implant Ti Female, Spacer & Analog Dalla Bona, Ti Female & Spacer only ORS, Retainer Rings (6) ORS, Combo O-Rings 10 red, 10 wt., 10 blk ORS, Implant Retainer Ring, Analog & O-Rings TOOLS Bio-Torq Socket Bio-Torq ORS / Dalla Bona Tip LT / RA Handle LT / RA ORS / Dalla Bona Tip Dalla Bona Activating Tool, Blue Dalla Bona Deactivating Tool, Yellow

F=3.4mm F=3.4mm H=2.0mm =5.1mm M=4.5mm

40-430002 99-451012 99-440044 99-443037 40-440002

40-430002 99-451012 99-440044 99-443037 40-440002

59-100190 59-100140 58-100190 58-100140 99-451017 99-451018

59-100190 59-100140 58-100190 58-100140 99-451017 99-451018

Tip: If you only need the male element Dalla Bona or ORS, replace the last zero of the order number with a 3. For example: 56-343010 is the DB Complete for IMZ 3.3. The male only is 56-343013.

All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

IMZ Non-Hex 3.3 & 4.0 Compatible


UBS BAR SYSTEM
The UBSUltimate Bar System is a convenient kit designed to facilitate the construction of implant bar retained overdentures. In designing this system, consideration has been given to function, ease of use and prevention of distal lift-off while allowing resiliency from the most anterior bar segment. Applications: Indications are for bar overdentures, precision partial dentures and patient removable implant restorations. Each system includes: 1 Hader-EDS Bar, green plastic (50mm) 6 Hader-EDS clips2 of each retention (2 white, 2 yellow, 2 red) 2 Hader-EDS Housings, gold plated stainless steel 1 Hader-EDS Seating Tool 2 SwissLoc Attachments 7.5mmadjustable to 4.0mm 2 SwissLoc Processing Jigs 1 PPM Bar 0 degree, blue plastic (50mm) 1 PPM 0 degree Mandrel 1 RA 1.5mm Reamer
Description UBS BAR KIT UBS - Ultimate Bar System

Overdenture Attachments Bar Type Reamers Lapping Tools

PPM Bar 0 degree

Hader-EDS Housings

Hader-EDS Clips

SwissLoc Attachments 7.5mm

Hader-EDS Bar

Order # 99-551000

Note: To purchase components or parts separately, refer to the respective pages in the Renew Biocare main catalog.

IMZ
REAMERS
The reamers are used to refine the internal access hole of a castable cylinder. The reamers also refine the seat for the head of the screw. The Reamer fits all UMA and IMZ IME European new style cylinders.
A

Description UMA, Reamer Gold Handle

Order # 11-000150

LAPPING TOOLS & PASTE


The Lapping tools are used with diamond polishing paste to refine the fitting surface of the cast cylinder. We recommend that you use it not more than 5-6 times. For superior restorations, you may want to use the 1 micron white diamond lapping paste. The lapping tool fits the cylinders for the Complete Abutment, IME and UMA.
B

Description UMA, Lapping Tool and Guide Pin Lapping Diamond Paste

Order # 11-000155 40-001010

All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

IMZ Non-Hex 3.3 & 4.0 Compatible


INSERTION DRIVERS
The Bio-Torq (B-T) and LT / RA Systems were designed to facilitate the insertion of implant components. The Bio-Torq Branemark compatible insertion tips may be utilized with the

Bio-Torq Drivers LT / RA Insertion Drivers Standard Drivers Wrenches

Bio-Torq socket / adapter or the Bio-Torq wrenches. The LT / RA (latch type) tips are used with right angle handpiece type drivers.

A
B-T LT / RA

B A

C
B-T LT / RA LT / RA

E D

B-T

LT / RA

B-T

LT / RA

B-T

Description

Order #

Order #

Bio-Torq
Hand Held Socket / Handle (A) Slot Tip Short Slot Tip Long (B) .050" Hex Tip Short .050" Hex Tip .Long (C) .048" Hex Tip Short .048" Hex Tip Long .9mm CS Hex Tip Short Complete Abutment Tip (D) UMA Tip Short (E) UMA Tip Long Bio-Torq Extension Note: For Slot Screws do not exceed 10 N/cm of torque. 59-100190 59-100110 59-100115 59-100120 59-100125 59-100130 59-100135 59-100200 N/A 59-100150 59-100155 59-100195

LT/ RA Driver
58-100190 58-100110 58-100115 58-100120 58-100125 58-100130 58-100135 N/A 58-100170 58-100150 N/A N/A

IMZ

STANDARD DRIVERS, B-T WRENCHES & LT / RA DRIVER

Description

Order #

Standard Drivers
DDS .050" Hex Driver (A) DDS Slot Screwdriver (B) Lab .050" Hex Driver (C) 11-000007 11-000005 11-000006

BIO-TORQ Wrenches & LT / RA Driver


BIO-TORQ Wrench 10 N/cm BIO-TORQ Wrench 20 N/cm BIO-TORQ Wrench 30 N/cm LT / RA Driver 59-100010 59-100020 59-100030 58-100000

All product names referenced herein are trademarks of their respective companies. 2002 AI/RBC, See Copyright & Disclaimer All Rights Reserved 1001 Bayhill Drive, San Bruno, CA 94066

10

You might also like