Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

PMT Hps 34 TT 03 16 stt750 Spec

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

SmartLine

Technical Information

STT750 SmartLine Temperature Transmitter


Specification 34-TT-03-16, March 2024

Introduction

Part of the SmartLine® family of products, the SmartLine


STT750 is a high-performance and value temperature
transmitter offering high accuracy and stability over a wide
range of process and ambient temperatures.
SmartLine easily meets the most demanding needs for
temperature measurement applications.

Best in Class Features:

Industry leading performance value

o Digital Accuracy up to .14 Deg C for RTD

o Stability up to +/-0.01% of URL per year for ten


years

o 125 mSec update time for single input models.

o 250 mSec update time for dual input models.

Reliable measurement

o Built in Galvanic Isolation


Figure 1– SmartLine STT750 Temperature
o Dual Compartment Housing transmitter
o Sensor Break detection

o Comprehensive on-board diagnostic capabilities Communications/Output Options:

o Full compliance to SIL 2/3 requirements. o 4-20 mA DC

o Available with 4 year warranty o HART ® (version 7.0)

o Supports Namur 89 Wire break All transmitters are available with the above listed
output and communication protocol option.
o Direct entry of Callendar-van Dusen coefficients
R0, α, δ and β for calibrated RTD sensors.

Lower Cost of Ownership


o Universal input
o Standard digital display capabilities
o Modular construction
o External zero, span, & configuration capability
o Polarity insensitive loop wiring
2 STT750 SmartLine Temperature Transmitter

Description Personal Computer Configuration

The STT750 SmartLine Temperature Transmitter is Field Device Manager (FDM) Software and FDM Express are
designed and manufactured to deliver high performance also available for managing HART device configurations.
across varying ambient temperature.
Diagnostics
Unique Indication/Display Options SmartLine transmitters all offer digitally accessible
The STT750 modular design accommodates a Standard diagnostics which aid in providing advanced warning of
possible failure events minimizing unplanned shutdowns,
LCD display.
providing lower overall operational costs
Standard LCD Display Features
System Integration
o Modular (may be added or removed in the field).
o 0, 90,180, & 270-degree position adjustments. o All SmartLine products meet the most current published

o Deg C, F, R, Kelvin, Milli volts, and Ohm measurement standards for HART.

units. Modular Design


o 2 Lines 6 digits PV (9.95H x 4.20W mm), 8 Characters. To help contain maintenance and inventory costs, all STT750
o Device configuration and calibration through integral transmitters are modular in design supporting the user’s
buttons or optional external buttons. ability to replace temperature boards, add indicators or
o Up to 4 configurable display screens. change electronic modules without affecting overall
performance or approval body certifications.
o Configurable screen rotation timing (2 to 20 sec).
o Write protect indication. Each temperature board is uniquely characterized to provide
o Critical fault indication. in-tolerance performance over a wide range of application
variations in temperature and due to the Honeywell advanced
Configuration Tools interface, electronic modules may be swapped with any
Integral Three Button Configuration Option electronics module without losing in-tolerance performance
Suitable for all electrical and environmental requirements, characteristics
SmartLine offers the ability to configure the transmitter and Modular Features
display via two buttons on the display and optional three o Replace temperature board, terminal board, or lightning
externally accessible buttons. The button compartment is protection*
isolated from other internal components and thus keeps the o Replace electronics or communication modules*
sensitive electronics environmentally sound. o Add or remove integral indicators*
Zero/span capabilities are also optionally available via these o Add or remove external configuration buttons
buttons with or without selection of a display option. * Field replaceable in all electrical environments (including IS)
except flameproof without violating agency approvals.
Handheld Configuration
SmartLine transmitters feature two-way communication and With no performance effects, Honeywell’s unique modularity
configuration capability between the operator and the results in lower inventory needs and lower overall
transmitter. This is accomplished via Honeywell Versatilis, a operating costs.
field-rated, next-generation multiple communication
configuration tool.

The Honeywell Versatilis Handheld is capable of field


configuring HART Devices and can also be ordered for use in
intrinsically safe environments.

All Honeywell transmitters are designed and tested for


compliance with the offered communication protocols and are
designed to operate with any properly validated hand-held
configuration device.
STT750 SmartLine Temperature Transmitter 3

Performance Specifications1,3
Reference Accuracy 2 (conformance to +/-3 Sigma)
Input Maximum Range Limits Digital Output D/A Standards
Type Accuracy Accuracy
(+/-) (% of span)

RTD °F
°C °C %
(2,3,4 wire)
Pt255 -200 to 850 -328 to 1562 0.90 0.025 IEC751 (=0.00385)

Pt100 -200 to 850 -328 to 1562 0.14 0.025 IEC751 (=0.00385)

Pt200 -200 to 850 -328 to 1562 0.28 0.025 IEC751(=0.00385)

Pt500 -200 to 850 -328 to 1562 0.17 0.025 IEC751 (=0.00385)


Pt1000 -200 to 500 -328 to 932 0.14 0.025 IEC751 (=0.00385)
Ni120 -80 to 260 -112 to 500 0.12 0.025 Edison Curve #7 (α=0.00672)
-58 to 482 Edison Copper Winding #15
Cu10 -50 to 250 1.40 0.025
(α=0.00427)
Thermocouples °C °F °C %
200 to 300 392 to 572 3.00 0.025 IEC 584-1 (ITS-90)
B
300 to 1820 572 to 3308 1.20 0.025 IEC 584-1 (ITS-90)

E -200 to 1000 -328 to 1832 0.40 0.025 IEC 584-1 (ITS-90)


J -200 to 1200 -328 to 2192 0.50 0.025 IEC 584-1 (ITS-90)
K -200 to 1370 -328 to 2498 0.50 0.025 IEC 584-1 (ITS-90)
N -200 to 1300 -328 to 2372 0.80 0.025 IEC 584-1 (ITS-90)
-50 to 0 -58 to 32 2.00 0.025 IEC 584-1 (ITS-90)
R
0 to 1760 32 to 3200 1.00 0.025 IEC 584-1 (ITS-90)
-50 to 0 -58 to 32 2.00 0.025 IEC 584-1 (ITS-90)
S
0 to 1760 32 to 3200 1.00 0.025 IEC 584-1 (ITS-90)
-250 to -200 -418 to 392 1.2 0.025 IEC 584-1 (ITS-90)
T
-200 to 400 -392 to 752 0.40 0.025 IEC 584-1 (ITS-90)
C (W5 W26) 0 to 2300 32 to 4172 1.20 0.025 ANSI/ASTM E-230 (ITS-90)

Digital Output D/A


Other Input
Maximum Range Limits Accuracy Accuracy Standards
Types
(+/-) (% of span)
Millivolts -100 to 1200 mV 0.17 mV 0.025
Millivolts -20 to 125 mV 0.021 mV 0.025
Ohms 0 to 500 Ohms 0.30 Ohms 0.025
Ohms 0 to 2000 Ohms 0.45 Ohms 0.025
Ohms 0 to 3000 Ohms 0.65 Ohms 0.025

1. Digital Accuracy is accuracy of the digital value accessed by the Host system and the handheld communicator.
2. Total analog accuracy is the sum of digital accuracy and output D/A Accuracy.
3. Output D/A Accuracy is applicable to the 4 to 20 mA Signal output.
4. For TC inputs, CJ accuracy shall be added to digital accuracy to calculate the total digital accuracy.
5. Custom Callendar-van Dusen not available for Pt25 sensors.
4 STT750 SmartLine Temperature Transmitter

Performance under Rated Conditions – All Models


Parameter Description
Input Span Adjustment Range No limits to adjustments within the maximum range except minimum span limit of 1
engineering unit
Analog Output Two-wire, 4 to 20 mA (HART transmitters only)
Digital Communications: HART 7 protocol compliant
Output Failure Modes Honeywell Standard: NAMUR NE 43 Compliance:
(HART only) Normal Limits: 3.8 – 20.8 mA 3.8 – 20.5 mA
Failure Mode: ≤ 3.6 mA and ≥ 21.0 mA ≤ 3.6 mA and ≥ 21.0 mA
Output Accuracy (HART only) ±0.025 % span
Supply Voltage Effect 0.005 % span per volt.
Transmitter Turn on Time
(includes power up & test HART: 2.5 sec.
algorithms)
Analog Input Stability: 0.01% of URL per year for 10 years
Maximum Lead Wire Resistance:
Thermocouples: 50 ohms/leg
RTD (all except Pt25) and ohms: 50 ohms/leg
RTD Pt25: 10 ohms/leg
Response Time HART Analog Output
(delay + time constant) 130 - 230 mSec
Update time 125 mSec
Damping Time Constant HART: Adjustable from 0 to 102 seconds in 0.1 increments. Default: 0.50 seconds
Ambient Temperature Effect Digital Accuracy
For RTD Inputs, 0.0025 °C/°C
For T/C Inputs: 0.010 °C/°C
Output D/A: 0.0010 % of span/°C
Cold Junction Accuracy ±0.25 °C
Total Reference Accuracy Digital Mode : Digital Accuracy + C/J Accuracy (T/C input types only)
Analog Mode (HART only):
Digital Accuracy + Output D/A Accuracy + C/J Accuracy (T/C input types only)
Example: Transmitter in Analog Mode with Pt100 sensor and 0 to 200°C range
Total Reference Accuracy = 0.14°C + (200 °C / 100 %) * 0.025 % = 0.19 °C
Sensor Burnout Burnout detection is user selectable. Upscale or down scale with critical status
message. For RTD or ohm type inputs; broken wire/wires will be indicated
Vibration Effect Per IEC60770-1 field or pipeline, high vibration level (10-2000Hz: 0.21
displacement/3g max acceleration)
Electromagnetic Compatibility IEC 61326-3-1
Isolation 2000 Vdc (1400Vrms) Galvanic isolation between inputs and output.
Stray Rejection Common Mode
AC (50 or 60 Hz): 120 dB (with maximum source impedance of 100 ohms) or ±
1 LSB (least significant bit) whichever is greater with line voltage applied.
DC: 120 dB (with maximum source impedance of 50 ohms) or a ±1 LSB whichever is
greater with 120 Vdc applied.
DC (to 1 KHz): 50 dB (with maximum source of impedance of 50 ohms) or ±1 LSB
whichever is greater with 50 Vac applied.
Normal Mode
AC (50 or 60 Hz): 60 dB (with 100% span peak-to-peak maximum)
EMC Compliance EN 61326-1 and EN 61326-3-1 (SIL)
Lightning Protection Option Leakage Current: 10 uA max @ 42.4 VDC 85 °C
Impulse rating: 8/20 uS 5000 A (>10 strikes) 10000 A (1 strike min.)
10/1000 uS 200 A (> 300 strikes)
STT750 SmartLine Temperature Transmitter 5

EMC Conformity (CE, Marine and SIL)

The STT750 device is compliant with IEC compliance EN 61326-1: 2013, EN IEC 61326-1: 2021 (CE) ; IEC 60533: 2015 /
IACS Req. 1991/Rev.8 2021 (Marine) and IEC 61326-3-1: 2017 (SIL)

Performance specifications under EMC conditions (CE and Marine):

HART: Worst case deviation < 0.1% of full span (for both Analog and Digital).

Operating Conditions – All Models

Reference Rated Condition Operative Limits Transportation and


Parameter
Condition Storage
C F C F C F C F
Ambient
0B Temperature1
STT750 25±1 77±2 -40 to 85 -40 to 185 -40 to 85 -40 to 185 -55 to 120 -67 to 248
Humidity %RH 10 to 55 0 to 100 0 to 100 0 to 100
HART Models: 11.8 to 42.4 Vdc at terminals (IS versions limited to 30 Vdc)
Supply Voltage
0 to 1,400 ohms (as shown in Figure 2)
Load Resistance
1
LCD Display operating temperature -20C to +70C . Storage temperature -30C to 80C.

Figure 2 – HART Supply voltage and loop resistance chart & calculations
6 STT750 SmartLine Temperature Transmitter

Materials Specifications (see model selection guide for availability/restrictions with various models)
Parameter Description
Mounting Bracket Wall or 2” Pipe, Carbon Steel (Zinc-plated) or 316 Stainless Steel
Pure Polyester Powder Coated Low Copper (<0.4%) – Aluminum.
Electronic Housing Meets Type 4X / IP66 / IP67. All stainless steel housing is optional.
Cover O ring material: Silicone
Sensor/Cable Entry 1/2 NPT electrical connection or M20x1.5
Can be mounted in virtually any position using the standard mounting brackets. Brackets
Mounting
are designed to mount onto a wall or a 2-inch (50 mm) vertical or horizontal pipe.
Wiring Accepts up to 16 AWG (1.5 mm diameter). Preferred 18AWG and above for ease of
wiring.
Dimensions See Figures 4 to 9
Net Weight Lbs (kg) Aluminum housing for transmitter with Display – 2.7 lbs (1.22 kg)
Aluminum housing for transmitter w/o Display – 2.6 lbs (1.18 kg)
Stainless Steel housing for transmitter with Display – 4.9 lbs (2.22 kg)
Stainless Steel housing for transmitter w/o Display – 4.8 lbs (2.18 kg)

Communications Protocols & Diagnostics

HART Protocol
Version:
HART 7
Power Supply
Voltage: 11.8 to 42.4Vdc at terminals
Load: Maximum 1400 ohms See figure 2
Minimum Load: 0 ohms. (For handheld communications, a minimum load of 250 ohms is required)
IEC 61508 Safety Certified SIL 2 and SIL 3

Standard Diagnostics
STT750 top level diagnostics are reported as either critical or non-critical as listed below. All diagnostics are readable via
the DD/DTM tools. All critical diagnostics will appear on the integral display.
Critical Diagnostics
Sensor Module Fault
Communications Module Fault
Sensor Communications Fault
Input Fault

IEC 61508 SIL 2 for non-redundant use and SIL 3 for redundant use according to EXIDA and
SIL 2/3 Certification TÜV Nord Sys Tec GmbH & Co. KG under the following standards: IEC61508-1: 2010; IEC
61508-2: 2010; IEC61508-3: 2010.
SIL EMI/EMC compliance as per Standard: IEC 61326-3-1: 2017
MARINE TYPE
American Bureau of Shipping (ABS); Certificate number: 23-2416104-PD
APPROVAL Lloyd’s Register (LR); Certificate number: LR23389941TA
STT750 SmartLine Temperature Transmitter 7

Wiring Diagram

Figure 3 STT750 Thermocouple, RTD, mV, ohm and Volt Connections


8 STT750 SmartLine Temperature Transmitter

Approval Certifications:

MSG AGENCY TYPE OF PROTECTION COMM Electrical Ambient Temperature


CODE OPTION Parameters
Explosion proof, Certificate:
FM16US0157X:
Class I, Division 1, Groups A, B, C, D; T 95oC, T5: Ta= -50oC
Dust Ignition Proof: 4-20 mA/ to 85oC
Class II, III, Division 1, Groups E, F, G; DE/HART/ F/ Note 1 T6: Ta= -50oC to 65oC
T6..T5 PROFIBUS

Class 1, Zone 1, AEx db IIC T6..T5 Gb


Zone 21 AEx tb IIIC T 95oC Db
Intrinsically Safe, Certificate:
FM
FM16US0157X: -50oC to 70oC
A Approvals TM
Class I, II, III, Division 1, Groups A, B, C,
(USA) 4-20 mA/
D, E, F, G; T4 FISCO:
DE/HART/FF/ Note 2
-50oC to 45oC
PROFIBUS
Class I Zone 0 AEx ia IIC T4 Ga
FISCO Field Device (Only for FF Option)
Class I Zone 0 Ex ia IIC T4 Ga
Non-Incendive, Certificate:
4-20 mA/
FM16US0157X: -50oC to 85oC
DE/HART/FF/ Note 1
Class I, Division 2, Groups A, B, C, D; T4
PROFIBUS
Class I Zone 2 AEx nA IIC T4 Gc
Enclosure: Type 4X/ IP66/ IP67 ALL ALL ALL
Explosion proof, Certificate: 2689056:
Class I, Division 1, Groups A, B, C, D;
Dust Ignition Proof:
Class II, Division 1, Groups E, F, G; Class
T 95oC, T5: Ta= -50oC
III, Division 1 ;T6..T5
4-20 mA/ to 85oC
Note 1
DE/HART/FF T6: Ta= -50oC to 65oC
Class I Zone 1 AEx db IIC T6..T5 Gb ;
Zone 21 Ex tb IIIC T 95oC Db

Ex db IIC T6..T5 Gb ;
Ex tb IIIC T 95oC Db
Intrinsically Safe, Certificate: 2689056:
Class I, II, III, Division 1, Groups A, B, C,
D, E, F, G; T4
CSA-Canada
B Class I Zone 0 AEx ia IIC T4 Ga
and USA
Class I Zone 2 Ex ic IIC T4 Gc -50oC to 70oC
4-20 mA/
Ex ia IIC T4 Ga Note 2 FISCO:
DE/HART/FF
Ex ic IIC T4 Gc -50oC to 45oC
FISCO Field Device (Only for FF Option)
Class I Zone 0 AEx ia IIC T4 Ga
Class I Zone 2Ex ic IIC T4 Gc
Ex ia IIC T4 Ga
Ex ic IIC T4 Gc
Non-Incendive, Certificate: 2689056:
Class I, Division 2, Groups A, B, C, D; T4
4-20 mA/
Note 1 -50oC to 85oC
DE/HART/FF
Class I Zone 2 AEx nA IIC T4 Gc
Ex nA IIC T4 Gc

Enclosure: Type 4X/ IP66/ IP67 ALL ALL ALL


STT750 SmartLine Temperature Transmitter 9

Standards: CSA C22.2 No. 0-10; CSA 22.2 No. 25-1966 (reaffirmed 2009);
CSA C22.2 No. 30-M1986 (reaffirmed 2012); CSA C22.2 No. 94-M91;
CSA C22.2 No. 61010-1: 2012; CSA-C22.2No.157-92 (reaffirmed 2012);
C22.2 No. 213-2017; C22.2 No. 60529-2016
C22.2 No. CSA 60079-0:2011; C22.2 No. 60079-1: 2011; C22.2 No. 60079-11:2014;
C22.2 No. 60079-15: 2012; C22.2 No. 60079-31:2015;
B
ANSI/ ISA12.12.01-2017; ANSI/ ISA 60079-0 (12.00.01): 2013;
ANSI/UL 60079-1 : 2015; ANSI/ ISA 60079-11(12.02.01) : 2012;
ANSI/ ISA 60079-15(12.12.02) : 2012 ;
ANSI/ ISA 60079-31: 2015;
FM Class 3615: Aug 2006; FM Class 3616: Dec 2011; ANSI/ IEC 60529 : Edition 2.1
ANSI/ UL 913: 2015; ANSI/UL 61010-1: 2016; UL 50: Ed 11
Flameproof, Sira 14ATEX2046X:
T 95oC, T5: Ta= -50oC
II 2 GD 4-20 mA/
Note 1 to 85oC
Ex db IIC T6..T5 Gb DE/HART/FF
T6: Ta= -50oC to 65oC
Ex tb IIIC T 95oC Db
Intrinsically Safe, Sira 14ATEX2046X:
II 1 GD -50oC to 70oC
Ex ia IIC T4 Ga 4-20 mA/
Note 2
Ex ia IIIC T95oC Da DE/HART/FF FISCO:
FISCO Field Device (Only for FF Option) -50oC to 45oC
Ex ia IIC T4 Ga
Enclosure: IP66/ IP67 ALL ALL ALL
C ATEX
Standards: EN 60079-0: 2012/A11:2013; EN 60079-1 : 2014; EN 60079-31 : 2014
EN 60079-11: 2011; EN 60079-26 : 2006; EN 60529 : 2000 + A1
Increase Safety/ Intrinsic Safety, Sira
14ATEX4052X:
II 3 G -50oC to 85oC
4-20 mA/
Ex ec IIC T4 Gc Note 1 FISCO:
DE/HART/FF
Ex ic IIC T4 Gc -50oC to 45oC
FISCO Field Device (Only for FF Option)
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67 ALL ALL ALL
Standards: EN 60079-0: 2012/A11:2013; EN 60079-7:2015; EN 60079-11:2012
Flameproof, SIR 14.0020X T 95oC, T5: Ta= -50oC
4-20 mA/
Ex db IIC T6..T5 Gb Note 1 to 85oC
o DE/HART/FF
Ex tb IIIC T 95 C Db T6: Ta= -50oC to 65oC
Intrinsically Safe, SIR 14.0020X
Ex ia IIC T4 Ga -50oC to 70oC
4-20 mA/
Ex ia IIIC T95oC Da Note 2 FISCO:
DE/HART/ FF
FISCO Field Device (Only for FF Option) -50oC to 45oC
Ex ia IIC T4 Ga
D IECEx Non Sparking, SIR 14.0020X
Ex ecIIC T4 Gc -50oC to 85oC
4-20 mA/
Ex ic IIC T4 Gc Note 1 FISCO:
DE/HART/ FF
FISCO Field Device (Only for FF Option) -50oC to 45oC
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67 ALL ALL ALL
Standards: IEC 60079-0: 2011; IEC 60079-1 : 2014,;
IEC 60079-11 : 2011; IEC 60079-7:2015;
IEC 60079-31 : 2013
10 STT750 SmartLine Temperature Transmitter

Flameproof: T 95oC, T5: Ta= --50oC


4-20 mA/
Ex db IIC T6..T5 Gb Note 1 to 85oC
DE/HART/FF
Ex tb IIIC T 95oC Db T6: Ta= -50oC to 65oC
Intrinsically Safe:
Ex ia IIC T4 Ga -50oC to 70oC
4-20 mA/
Ex ia IIIC T95oC Da Note 2 FISCO:
SAEx DE/HART/FF
FISCO Field Device (Only for FF Option) -50oC to 45oC
E (South Ex ia IIC T4 Ga
Africa) Increase Safety/ Intrinsic Safety:
Ex ec IIC T4 Gc -50oC to 85oC
4-20 mA/
Ex ic IIC T4 Gc Note 1 FISCO:
DE/HART/FF
FISCO Field Device (Only for FF Option) -50oC to 45oC
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67 ALL ALL ALL
Flameproof: T 95oC, T5: Ta= -50oC
4-20 mA/
Ex db IIC T6..T5 Gb Note 1 to 85oC
DE/HART/FF
Ex tb IIIC T 95oC Db T6: Ta= -50oC to 65oC
Intrinsically Safe:
Ex ia IIC T4 Ga -50oC to 70oC
4-20 mA/
Ex ia IIIC T95oC Da Note 2 FISCO:
DE/HART/FF
FISCO Field Device (Only for FF Option) -50oC to 45oC
F INMETRO
Ex ia IIC T4 Ga
Increase Safety/ Intrinsic Safety:
Ex ec IIC T4 Gc -50oC to 85oC
4-20 mA/
Ex ic IIC T4 Gc Note 1 FISCO:
DE/HART/FF
FISCO Field Device (Only for FF Option) -50oC to 45oC
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67 ALL ALL ALL
Flameproof: T 95oC, T5: Ta= -50oC
4-20 mA/
Ex d IIC T6..T5 Gb Note 1 to 85oC
DE/HART/FF
Ex tD A21 IP66/IP67 T95oC T6: Ta= -50oC to 65oC
Intrinsically Safe:
Ex ia IIC T4 -50oC to 70oC
4-20 mA/
NEPSI Ex iaD 20 T95oC Note 2 FISCO:
G DE/HART/FF
(CHINA) FISCO Field Device (Only for FF Option) -50oC to 45oC
Ex ia IIC T4
Non Sparking/ Intrinsic Safety:
4-20 mA/ -50oC to 85oC
Ex nA IIC T4 Note 1
DE/HART/FF
Ex ic IIC T4 Gc
Enclosure: IP66/ IP67 ALL ALL ALL
H KOSHA Flameproof:
4-20 mA/
(KOREA) Ex d IIC T4 Gb Note 1 -50oC to 85oC
DE/HART/FF
Ex tD A21 T 95oC IP 66/ IP67
Intrinsically Safe:
-50oC to 70oC
Ex ia IIC T4 4-20 mA/
Note 2 FISCO:
FISCO Field Device (Only for FF Option) DE/HART/FF
-50oC to 45oC
Ex ia IIC T4
Enclosure: IP66/ IP67 ALL ALL ALL
STT750 SmartLine Temperature Transmitter 11

J EAC Ex Flameproof:
4-20 mA/
(Russia, 1 Ex d IIC T4 Gb Note 1 -50oC to 85oC
DE/HART/FF
Belarus and Ex tb IIIC T95oC Db
Kazakhstan) Intrinsically Safe:
0 Ex ia IIC T4 Ga -50oC to 70oC
4-20 mA/
Ex ia IIIC T4 Db Note 2 FISCO:
DE/HART/FF
FISCO Field Device (Only for FF Option) -50oC to 45oC
0 Ex ia IIC T4 Ga
Non Sparking: 4-20 mA/
Note 1 -50oC to 85oC
2 Ex nAc IIC T4 DE/HART/FF
Enclosure: IP66/ IP67 ALL ALL ALL
P CCoE Ex ia IIC T4 Ga -50oC to 70oC
4-20 mA/
(India) FISCO Field Device (Only for FF Option) Note 2 FISCO:
DE/HART/FF
Ex ia IIC T4 -50oC to 45oC
Ex d IIC T4 Gb 4-20 mA/
Note 1 -50oC to 85oC
DE/HART/FF

Notes
1. Operating Parameters:
4-20 mA/ HART (Loop Terminal)
Voltage= 11.8 to 42 V Current= 4-20 mA Normal (3.8 – 23 mA Faults)

2. Intrinsically Safe Entity Parameters

Analog/HART Entity Values

Loop, Terminals 1 and 2:


Vmax = Ui = 30V Imax= Ii = 225mA Ci = 12nF Li = 0µH Pi = 0.9W

Temperature Sensor, Terminals 5, 6, 7 and 8:


Uo = 5.9V Imax= Io = 2.65mA Co = 39µF Lo = 4.99H Po = 15.48mW
12 STT750 SmartLine Temperature Transmitter

ounting & Dimensional Drawings

TRANSMITTER ENCLOSURE CAN BE ROTATED A TOTAL OF 90º FROM THE STANDARD MOUNTING POSITION

Figure 4 – STT750 with adapter housing - Horizontal Wall Mounting

Figure 5 – STT750 No-Adapter Horizontal Wall Mounting


STT750 SmartLine Temperature Transmitter 13

Figure 6 – STT750 Pipe Mount with adapter housing - Horizontal & Vertical

Figure 7 – STT750 Pipe Mount, Vertical

*Note 1: Figure 6 and 7. The housing adapter may not be present on all transmitter models. If the housing adapter is not
present, subtract 24,5mm (0,96 inches) from the dimension specified.
14 STT750 SmartLine Temperature Transmitter

Mounting & Dimensional Drawings

millimeters
Reference Dimensions: A

inches E

Figure 8 – STT750 with adapter housing - Dimensions


STT750 SmartLine Temperature Transmitter 15

Figure 9 – STT750 no adapter housing dimensions


16 STT750 SmartLine Temperature Transmitter

The Model Selection Guide is subject to change and is inserted into the specification as guidance only.

Model Selection Guide

Section 13
Page: STT7-1
Model STT750 Effective Date: January 12, 2024

Smart Temperature Transmitter


Model Selection Guide: Model Selection Guide
34-44-16-20 Issue 21 Honeywell Proprietary
Instructions: Make selections from all Tables Key through XIII using column below the proper arrow. Asterisk indicates
availability. Letter (a) refer to restrictions highlighted in the restrictions table. Tables delimited with dashes.
List Price equals
List Price: Price equals the sum of prices for all selections made.
the sum of all
Key I II III IV V VI VII VIII IX
selections
STT750 - _ - _ - _ - ___ - ___ - _ - ____ - _ _, _ _, _ _ - XXXX made.

Availability
KEY NUMBER INPUT TYPE Selection
Universal Input STT750 *

TABLE I NUMBER OF INPUTS


Input Details Single S *

TABLE II DIGITAL OUTPUT


Digital Output No 0 *

TABLE III AGENCY APPROVALS (See data sheet for Approval Code Details)
No Approvals Required 0 *
FM Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof A *
CSA Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof B *
ATEX Explosion proof, Intrinsically Safe & Non-incendive C *
IECEx Explosion proof, Intrinsically Safe & Non-incendive D *
Approvals SAEx Explosion proof, Intrinsically Safe & Non-incendive E *
INMETRO Explosion proof, Intrinsically Safe & Non-incendive F *
NEPSI Explosion proof, Intrinsically Safe & Non-incendive G *
KOSHA Explosion proof, Intrinsically Safe & Non-incendive H *
EAC Explosion proof, Intrinsically Safe & Non-incendive J *
CCoE Explosion proof, Intrinsically Safe & Non-incendive P *
TABLE IV TRANSMITTER ELECTRONICS SELECTIONS
Housing and Material Connection Lightning protection
Polyester Powder Coated Aluminum 1/2 NPT Yes C_ _ *
a. Electronic
Housing Material & Polyester Powder Coated Aluminum M20 Yes D_ _ *
Connection Type 316 Stainless Steel (Grade CF8M) 1/2 NPT Yes G_ _ *
316 Stainless Steel (Grade CF8M) M20 Yes H_ _ *
Analog Output Digital Protocol
b. Output/ Protocol
4-20mA dc Ext Zero, Span & HART Protocol _H_ *
Indicator Config Buttons Languages
None None None __0 *
None Yes (Zero/Span Only) None __A *
c. Customer Standard (w/internal
Interface Zero, Span & Conf None English __S *
Selections Buttons)
Standard (w/internal
Zero, Span & Conf Yes English __T *
Buttons)

TABLE V CONFIGURATION SELECTIONS


a. Application Diagnostics
Software Standard Diagnostics 1__ *
3
Write Protect Fail Mode High & Low Output Limits
b. Output Limit, Disabled High> 21.0mAdc Honeywell Std (3.8 - 20.8 mAdc) _1_ *
Failsafe & Write Disabled Low< 3.6mAdc Honeywell Std (3.8 - 20.8 mAdc) _2_ *
Protect Settings Enabled High> 21.0mAdc Honeywell Std (3.8 - 20.8 mAdc) _3_ *
Enabled Low< 3.6mAdc Honeywell Std (3.8 - 20.8 mAdc) _4_ *
c. General Factory Standard __S *
Configuration Custom Configuration __C *
3
NAMUR Output Limits 3.8 - 20.5mAdc can be configured by the customer or select custom configuration Table Vc
STT750 SmartLine Temperature Transmitter 17

TABLE VI CALIBRATION & ACCURACY SELECTIONS


a. Accuracy and Accuracy Calibrated Range Calibration Qty
Calibration Standard Factory Std Single Calibration A *
Standard Custom (Unit Data Required) Single Calibration B *

TABLE VII ACCESSORY SELECTIONS


Bracket Type Material
None None 0___ *
Flat Pipe Mounting Bracket Carbon Steel 1___ *
a. Mounting Flat Pipe Mounting Bracket 316 SS 3___ *
Bracket Angle Pipe Mounting Bracket Carbon Steel 2___ *
Angle Pipe Mounting Bracket 316 SS 4___ *
Wall Mounting Bracket Carbon Steel 5___ *
Wall Mounting Bracket 316 SS 6___ *
Customer Tag Type
No customer tag _0__ *
b. Customer
One Wired Stainless Steel Tag (Up to 4 lines 26 char/line) _1__ *
Tag
Two Wired Stainless Steel Tag (Up to 4 lines 26 char/line) _2__ *
One Wired Stainless Steel Blank Tag (Up to 4 lines 26 char/line) _3__ *
Unassembled Conduit Plugs & Adapters
No Conduit Plugs or Adapters Required _ _ A0 *
c. Unassembled
1/2 NPT Male to 3/4 NPT Female 316 SS Certified Conduit Adapter _ _ A2 n
Conduit
1/2 NPT 316 SS Certified Conduit Plug _ _ A6 n
Plugs &
M20 316 SS Certified Conduit Plug _ _ A7 m
Adapters
Minifast® 4 pin (1/2 NPT) (not suitable for X-Proof applications) _ _ A8 n
Minifast® 4 pin (M20) (not suitable for X-Proof applications) _ _ A9 m
TABLE VIII OTHER CERTIFICATIONS AND OPTIONS
None - No additional options 00 *
Marine Approval MT d
Certificate of Conformance F3 *
Calibration Test Report & Certificate of Conformance F1 *
b
c. Certifications Certificate of Origin F5 *
and Warranty SIL2/3 Certificate FE j
Extended Warranty Additional 1 year 01 *
Extended Warranty Additional 2 years 02 *
b
Extended Warranty Additional 3 years 03 *
Extended Warranty Additional 4 years 04 *
TABLE IX MANUFACTURING SPECIALS
Factory Factory Identification 0000 *

MODEL RESTRICTIONS
Available Only with Not Available with
Restriction Letter
Table Selection(s) Table Selection(s)
j Vb _ 1,2 _
d VIIa 1,3,5,6
m IVa D,H, _ _
n IVa C,G, _ _
b Select only one option from this group

FIELD INSTALLABLE REPLACEMENT PARTS


Description Kit Number Price
Integrally Mounted Standard Indicator Kit 50126003-501 Note P
Single Input Terminal Strip w/Lightning Protection for HART Modules 50086421-513 Note P
HART Electronics Module Kit 50086423-501 Note P
HART Electronics Module w/connection for external configuration buttons 50086423-502 Note P
Note P - For part number pricing please refer to WEB Channel.
PRODUCT MANUALS
Description Part Number
Product Manual STT750 Smart Temperature Transmitter User Manual - English 34-TT-25-13
Product Manual STT850/750 Smart Temperature Transmitter Safety Manual - English 34-TT-25-05
Product Manual STT850 Smart Temperature Transmitter HART Communications Manual - English 34-TT-25-15
All product documentation is available at www.process.honeywell.com.
Sales and Service
For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one
of the offices below.

ASIA PACIFIC EMEA AMERICA’S


Honeywell Process Solutions, Honeywell Process Solutions, Honeywell Process Solutions,
(TAC) hfs-tac- Phone: + 80012026455 or Phone: (TAC) 1-800-423-9883 or
support@honeywell.com +44 (0)1202645583 215/641-3610
(Sales) 1-800-343-0228
Australia Email: (Sales)
Honeywell Limited FP-Sales-Apps@Honeywell.com Email: (Sales)
Phone: +(61) 7-3846 1255 or FP-Sales-Apps@Honeywell.com
FAX: +(61) 7-3840 6481 (TAC) or
Toll Free 1300-36-39-36 hfs-tac-support@honeywell.com (TAC)
Toll Free Fax: hfs-tac-support@honeywell.com
1300-36-04-70 Web
Knowledge Base search engine Web
China – PRC - Shanghai http://bit.ly/2N5Vldi Knowledge Base search engine
Honeywell China Inc. http://bit.ly/2N5Vldi
Phone: (86-21) 5257-4568
Fax: (86-21) 6237-2826

Singapore
Honeywell Pte Ltd.
Phone: +(65) 6580 3278
Fax: +(65) 6445-3033

South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799 6114
Fax: +(822) 792 9015

Specifications are subject to change without notice.

For more information


To learn more about SmartLine Temperature,
visit www.process.honeywell.com
Or contact your Honeywell Account Manager

Process Solutions
Honeywell
2101 City West Blvd
Houston, TX 77042

Honeywell Control Systems Ltd


Honeywell House, Skimped Hill Lane
Bracknell, England, RG12 1EB
Shanghai City Centre, 100 Jungi Road
Shanghai, China 20061 34-TT-03-16
March 2024
www.process.honeywell.com ©2024 Honeywell International Inc.