Datasheet Storage M Series
Datasheet Storage M Series
Datasheet Storage M Series
February 2016
High Performance
&
High Availability
IT Cost
Optimization
2
NEC Storage M Series
The ever increasing growth of data mandates IT reforms by implementing virtualized and cloud based environments.
This drastically changing environment requires a storage unit designed with these changes in mind. NEC’s M Series
storages have been developed to satisfy these needs by bringing together high reliability technology, functional
software, and tools to maximize productivity of virtualized and cloud environments.
M Series provides high performance and high availability to support business continuity, advanced eco-friendly
performance to reduce power consumption and cooling costs, easy installation and operation to reduce management
workload, and economic efficiency to meet today’s TCO demands to store and archive data. M Series utilizes
advanced storage virtualization technologies such as thin provisioning, data allocation optimization leveraging
high-speed solid state drive (SSD), and volume management which are compatible with server virtualization.
M Series offers a diverse product lineup including basic models (M110 & M310), high performance models (M510 &
M710), hybrid versions of models, and All Flash Storage (M310F & M710F) optimized for SSD to achieve higher
performance and faster response, all developed to respond to the needs of the next generation infrastructures.
M710
M710F
M510
Max. 48 ports
(FC/ISCSI) Max. 48 ports
Max. 960 drives (FC/ISCSI)
M310
Max. 32 ports
(FC/ISCSI) Max. 960 drives
Max.768 drives
M110 M310F
Max. 8 ports
(FC/ISCSI)
Max. 480 drives
Max. 8 ports Max. 8 ports
(FC/ISCSI/SAS) (FC/ISCSI)
Max. 120 drives Max. 480 drives
Automatic allocation of data to a suitable device according to its access Eco-friendly design employs 80PLUS® PLATINUM and 80PLUS®
frequency. GOLD certified high-efficiency power supplies as well as low-power
All components are redundant to provide maximum availability. processors.
High availability and reliability with NEC’s patented Super Phoenix M Series can be used even in 40°C(104°F) environments, reducing
Technology. cooling and electricity cost.
Superior security with Self Encrypting Drives and Secure Erasure function. Reduce power consumption by providing a visual power consumption
All Flash Storage optimized for flash to accelerate business applications display in GUI and implementing autonomous MAID function.
and improve response time. ENERGY STAR certified. (M110)
Dynamic Pool management enables expansion of capacity and performance without Devices (SAS, Nearline SAS, SSD) and interfaces (FC, iSCSI, SAS)
disruption. can be selected and intermixed according to your needs, optimizing
Thin Provisioning provides non-disruptive scaling capacity through over-subscription. investment cost.
Remote backup is easy and economical using a direct iSCSI interface, eliminating Management software and basic replication is bundled with the entry
complexity and cost of an FC to iSCSI gateway. level M110.
Data can be migrated between storage units without using an FC switch. Management in a virtual environment is simplified through integration
User-friendly GUI makes storage management and operation easy. with virtualization management software.
3
Virtualization with NEC Storage M Series
M Series supports VMware vSphere Virtual Volumes (VVOL) feature that LUN LUN
VM 1
Backup
enables storage features like backup & restore, snapshot, and Quality of VM 1 VM 1 Backup
VM 2 VM 2
Service (QoS) to be done at the VVOL level. VM 2 VM 2
Restore
Restore
VM 3 VM 3
M110 M310 M510 M710 M310F M710F VM 3
M series can control I/O flow by setting I/O threshold limits to each Task Important Average Average Server Important Average Average Server
level
High load High load
logical disk. Unlike many others, M Series allows both minimum and Performance Storage Storage
degradation
maximum thresholds to be used. It allows storage resources to be fairly A B C
Stable
performance A B C
Load suppression
allocated to normal priority applications while priority tasks preferentially (IOPS) (IOPS)
A A Ensure performance
acquire needed resources. M series stabilizes operations of the entire by setting a lower
limit.
system, allowing you to meet SLAs that require guaranteed Quality of B
B Suppress performance
to a certain level by
Service (QoS). C C
setting an upper limit.
Hybrid Data Tiering automatically tiers data to the most Application server Application server Application server
suitable device according to access frequency
M Series can create tiers with different types of devices; SSD, SAS HDD Automatically allocating the Automatically allocating the
stored data to a suitable stored data to a suitable
and Nearline SAS HDD. Once stored, data is automatically reallocated to device according to access device according to access
frequency (Logical disk unit). frequency (Block-data unit).
a suitable tier through routine monitoring so that frequently accessed NEC Storage
M Series
data is moved to a high speed SSD pool and infrequently accessed data
High High SSD pool
is moved to a low-cost nearline SAS pool. This keeps data on the
appropriate tier as access patterns change, maximizes storage Cost Performance SAS pool
read
M Series uses SSD which has a superior read performance as L2 cache, Write
NEC Storage M Series
Controller Controller
so throughput of frequently accessed data can be improved. In case of
Persistent write SSD L2 cache
an error in one controller, Persistent Write will continue Fast Write Continuing FastWrite operations by Removing hot spots by storing
maintaining redundant data when an frequently accessed data in a
operations, storing write data in SSD to keep data redundancy. error occurs in one controller. SSD SSD.
4
NEC Storage M Series
Thin provisioning maximizes storage investment efficiency by virtualizing Assigned capacity Assignment
Assign actual capacity monitoring history
logical volumes. Thin provisioning allows logical volumes to be oversubscribed, Logical disk when data is written. accumulation
Virtual capacity:10TB Storage and analysis
Add hard disk
making the logical volume look as if it has more physical resources than drives as Actual Pool capacity:
Manager
required. capacity:5TB 15TB
actually in the system. When physical capacity is insufficient, new physical
Threshold
Advanced dynamic pool value:
capacity can be non-disruptively added to the virtual volume. Thin provisioning Free:10TB
13TB
HDD HDD HDD HDD HDD Used:5TB
HDD Management
allows lower initial investment cost and lower power cost. server
Constructing a backup site can cost a great deal of money and Low-cost remote replication
without an FC-IP converter.
resources. M Series’ Remote Data Replication (RDR) uses an IP line with
iSCSI eliminating the need for an FC-IP converter. This enables
FC or iSCSI iSCSI Public line iSCSI FC or iSCSI
development of cost-efficient disaster prevention and response
measures. In addition, low-cost operation is possible due to reduced
total network setup & operational cost.
M110 M310 M510 M710 M310F M710F DDR RDR DDR
Master Replica Replica Replica
M Series M Series
M Series can perform direct backup & restore to NEC HYDRAstor (HS NEC Storage M series NEC Storage HS series
Data Data 6
HDD capacity is increasing so is the risk of data loss because a second HDD can fail while recovering a damaged HDD. M Series exploits NEC’s
patented RAID triple mirror that achieves the high-speed performance of RAID-1 with the double parity reliability of RAID-6.
M110 M310 M510 M710 M310F M710F
5
Green technology with NEC Storage M Series
Power consumption(kwh)
environment can be managed with real-time visualizations. In addition,
components such as CPU, fan and HDD autonomously control power
Autonomous
consumption based on storage unit usage. Energy efficient operations control
are also promoted by reduction of unnecessary power consumption
I/O count
when the storage unit is in the idle state.
M110 M310 M510 M710 M310F M710F
M Series adopts MAID (Massive Array of Inactive Disks) technology for In use Copying
Business volume ON
OFF ON OFF
Backup volume
6
NEC Storage M Series
Category Software Product Name M110 M310 M510 M710 M310F M710F Feature
Storage Management
NEC Storage Manager *1 *1 *1 *1 *1 Integrated storage operations management
Device Management NEC Storage Manager Integration Base *1 *1 *1 *1 *1 Integrated operations management in collaboration with SigmaSystemCenter
NEC Storage Manager Suite Package product consists of Storage Manager and Integration Base
NEC Storage PerformanceMonitor Monitors storage performance in real-time and accumulates monitoring data
NEC Storage PerformanceNavigator Efficiently analyzes storage performance data
Performance Management
NEC Storage PerformanceMonitor Suite Package product consists of PerformanceMonitor and PerformanceNavigator
NEC Storage Analyzer for VMware vCenter Operations Collaborates with VMware to analyze server and storage performance together
Replication Management NEC Storage ReplicationNavigator Suite Facilitates creation of backup system
Storage Control
NEC Storage BaseProduct Basic functions to control storage
Storage Control NEC Storage Manager Express *2 *1 *1 *1 *1 *1 Operations management of one storage without management server
NEC Storage ControlCommand *2 *1 *1 *1 *1 *1 CLI to control storage from application servers
NEC Storage DynamicDataReplication *3*4 Replicates volume in the same storage unit
NEC Storage RemoteDataReplication *3 Replicates volume in a remote storage unit
NEC Storage RemoteDataReplication Asynchronous *3 Asynchronously creates a remote replication volume through low-speed line
Replication NEC Storage DynamicSnapVolume *3*5 *5 *5 *5 *5 *5 Creates a snapshot which is the differential of original volume
NEC Storage DirectDataShadow Option Creates backup of M Series volumes in HS Series without backup server
NEC Storage ReplicationControl SQL Option Enables non-disruptive backup of Microsoft SQL Server
NEC Storage ReplicationControl FileSystem Option Enables non-disruptive backup of Linux file systems
Disaster Recovery NEC Storage RemoteDataReplication/DisasterRecovery Creates a remote replication volume, keeping consistency in case of disaster
NEC Storage VirtualCachePartitioning Divides storage cache memory and allocates them to tenants
NEC Storage ThinProvisioning *2 *1 *1 *1 *1 *1 Virtualizes volume capacity to show it has more capacity than actually has
NEC Storage StoragePowerConserver *2 *1 *1 *1 Reduces power consumption by powering off the motor of unused HDD
NEC Storage PerforOptimizer *6 *6 Autonomously reallocates the data according to the access frequency
NEC Storage PerforCache Uses SSD as L2 cache memory
Resource Control
NEC Storage DataMigration *2 *1 *1 *1 *1 *1 Migrates data from an existing NEC storage unit to M Series unit
NEC Storage VolumeProtect Preserves data in a tamper proof format for retention period
NEC Storage IO Load Manager Controls I/O flow corresponding to the upper/lower limit set to each volume
NEC Storage Virtual Volume Collaborates with VMware Virtual Volume to operate corresponding to VM
NEC Storage SecureEraser Securely erases the data in storage
High Availability NEC Storage PathManager *2 Automatically switches path in case of I/O path failure
*1: Eco Symbol & Eco Symbol Star are self-declaration type of ISO environmental labels (Type ll).
For details, see the following web site.
http://www.nec.com/en/global/eco/product/eco_pro/index.html
Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries.
Linux is a trademark or registered trademark of Linus Torvalds in the United States and other countries.
Red Hat is a trademark or registered trademark of Red Hat, Inc in the United States and other countries.
VMware is a trademark or registered trademark of VMware, Inc. in the United States and other countries.
All other products, brands, and trade names used in this document are trademarks or registered trademarks of their respective holders.
Before you use this product, please read carefully and comply with the cautions and warnings in manuals such as User’s Guide and
Safety notice Installation Guide. Incorrect use may cause a fire, electrical shock or injury.
For further information please contact your local NEC representative or:
Corporate Headquarters (Japan) North America (USA, Canada) APAC (South Asia, South East Asia, Oceania) EMEA (Europe, Middle East, Africa)
NEC Corporation NEC Corporation of America NEC Asia Pacific Pte. Ltd. NEC Enterprise Solutions
www.nec.com www.necam.com sg.nec.com www.nec-enterprise.com
Specifications and designs in this catalog are subject to change for improvement without notice.