ULTRASONIC INSPECTION REPORT

Page 1 of 3

Project: EACOP-JETTY & Company: EACOP Report No: ETJ-NDT-MUT-REP-00162


LOADING OUT FACILITY
Contractor: BBN LIMITED TZA Subcontractor: PEWCAT Ltd
Weld Completion Date :23- Oct -2024
Test Date: 23- Oct-2024
Job No: NA Location: Shallow Item Description: XH-45

Part Number & Revision Level: NA Serial Number: NA

Material: CARBON STEEL Weld Process: FCAW NDT Req. No.: ETJ-NDT-REQ-294

Equipment Make & Model: DOPPLER /ANYSCAN-30 Equip. Serial No: AA002HHA063

Cable Type & Length: Coaxial (Lemo - Lemo) Calibration / Ref. block: V1 (No. 598793), DAC (No. 403221)

Calibration date & Ref: 08-Jan.-2024 Test sensitivity: DAC 3mm Dia SDH
Couplant: Wall Paper Paste Surface Condition: As Welded & Cleaned Ref. Spec: EN 1090-2
Test Standard: BS EN ISO 17640:2018 Category: B Test %: 100
Procedure & Rev Ref: TZ-TAN-93-BBJ1-030143 Rev. 01 Acceptance Criteria: BS EN ISO 11666:2018 (Table: A.1-
Acceptance Level 2)
TRANSDUCERS
Make Freq- Mhz Angle Size (mm) Serial No Ref. dB T/C (dB) Scanning dB Range (mm)

Doppler 4 0 deg 10 Ø HLC366 31 0 +6 50

Doppler 4 45 deg 8x9 NFA007 37 2.0 +6 100


Doppler 4 60 deg 8x9 IDA294 38.5 2.0 +6 120
Doppler 4 70 deg 8x9 NCA206 44 2.0 +6 150
ATEL 4 80 deg 8x9 2403132 54 2.0 +6 180
Primary Ref. Response dB %: Scanning From: NA

Weld Pipe ø /Weld Material Discontinuity (mm) Disconti


JOINT Joint Length Indication Accept /
Drg. No Welder ID Thk Heig nuity
Reject
ID Type (mm) % Location Length Depth Type
(mm) ht
BBN-WDR-
TZ-TAN-93- J-5 012/013(0-180) BW 1168/3669 19 Ref dB 1700- 35 5-6 1 P Reject
BBJ1-231193 + 3.5 1735
BBN-WDR-
029/022(180- Ref dB 1900- 28 5-7 2 P Reject
360) + 4.5 1928

REMARKS:

LEGEND: P= Planar, NP= Non-planar.

PEWCAT NDT Operator BBN QC (review only) COMPANY REP


Name: IMAGWE MARCUS
Level: UT-Level 3 (ISO 9712)
Sign:

Date: 23-Oct-2024

ETJ-PC-QA-FO-GEN-ND-0002
ULTRASONIC INSPECTION REPORT
Page 2 of 3

ETJ-NDT-MUT-REP-00162

ETJ-PC-QA-FO-GEN-ND-0002
ULTRASONIC INSPECTION REPORT
Page 3 of 3

ETJ-NDT-MUT-REP-00162
PLAN VIEW
Weld Filling 180
& Cap

Weld Root &


BBN-WDR-012/013 Hot Pass
(0-180⁰) BBN-WDR-029/022
(180-360⁰)
1 1

CROSS SECTIONAL VIEW

1 2

45⁰ 45⁰