F - NDT - 002

PT RADIANT UTAMA INTERINSCO Tbk

ULTRASONIC EXAMINATION REPORT

CLIENT : PT BUMI BEAM CENTER REPORT NO. : 01/UT/BBC-RUI/VII/23


JOB : UT FLAW SHEET NO. : 1 OF 3
CONTRACT NO. : DATE : July 24, 2023
LOCATION : CIREBON, WEST JAVA

DETAILS OF JOB

ITEM NO. : A-B57.1 S O P NO. : NDT 027


SUBJECT : STRUCTURE BUTT JOINT CRITERION : AWS D1.1
& T-JOINT THICKNESS : 8 & 12 mm
DRAWING NO. : SURFACE CONDITION : SMOOTH
MATERIAL : CARBON STEEL SURFACE TEMP. : AMBIENT
STAGE OF EXAMINATION :
BEFORE/AFTER PWHT BEFORE/AFTER HYDROTEST √ AFTER WELD

EQUIPMENT

FLAW DETECTOR : KRAUTKRAMER USM 35X S/N : 4419a


PROBES USED :
ANGLE PHOENIC TC 0° GSW 700
SIZE Ø 10 mm 8 x 9 mm
FREQUENCY 5 MHZ 4 MHZ
S/N 21675 23285

CALIBRATION FOR SENSITIVITY

COMPRESSION WAVES
DISTANCE : 100 mm SEN. SETTING : 100 mm 43.5 dB 80 % FSH
inch inch
SHEAR WAVES
DISTANCE : 100 mm SEN. SETTING : Ø 1.5 mm 66 dB 60 % FSH
inch SDH inch
CALIBRATION BLOCK(S) : V1 & V2 S/N : 0998 11 & 18-036
COUPLANT : CMC SOLUTION

SCANNING PROCEDURES
SINGLE TRAVERSE DOUBLE TRAVERSE TRIPLE TRAVERSE
√ √
SCANNING TECHNIQUES
ROTATIONAL ORBITAL LATERAL TRAVERSING
√ √ √ √

ORIGINAL (PT RUI-JKT)


F - NDT - 004
PT RADIANT UTAMA INTERINSCO Tbk

REPORT NO. : 01/UT/BBC-RUI/VII/23


+
X X
SHEET NO. : 2 of 3
-
Y
DATE : July 24, 2023
SKETCH

FACE C

FACE A

FACE B
FACE B FACE A

LAMINATION CHECK : √ NO LAMINATION LAMINATION FOUND

Discontinuity Evaluation
Weld/Joint Identification

Decibels Discontinuity
Distance
Attenuation
Indication Number

Transducer Angle

Angular Distance
Indication

Indication
Reference
Welder Stamp

Rating

Remarks
(Sound Path)
Level

Level

Level

"A" Surface
Depth from

From From
From Face
Number

X Y
Length

a b c d
Leg

J1 - - 70° A&B 1/2 - 66 - - - - - - - - ACC


J2 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
J3 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
J3 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
J4 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
J4 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
J5 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
J6 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
J7 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
J8 - - 70° A&B 1/2 - 66 - - - - - - - - ACC
EXAMINER QA/QC INSPECTOR AUTHORIZED INSPECTOR CLIENT'S REP.

ILHAM PUTRA
DATE : July 24, 2023 DATE : DATE : DATE :
PT. RADIANT UTAMA INTERINSCO

ORIGINAL (PT RUI-JKT)


PT RADIANT UTAMA INTERINSCO Tbk

PHOTOGRAPH
TAG / LINE : A-B57.1 Sheet : 3 of 3

J3
J1
J2

J4
J5 J6

J5 J6