Data sheet for SIMOTICS M-1PH8

Article No. : 1PH8105-1CF02-3LC2 Figure similar

Client order no. : Item no. :


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Engineering data

PN MN IN UN fN nN Mmax Imax nmax M0 I0 Iμ


[kW] [Nm] [A] [V] [Hz] [rpm] [Nm] [A] [rpm] [Nm] [A]
η cos φ [A]

ALM 400V 8.0 44.0 17.5 400 60.2 1,750 103 41.0 9,000 52.0 20 0.878 0.780 8.8

BLM/SLM 400V 7.0 45.0 17.5 348 51.9 1,500 103 41.0 9,000 52.0 20 0.867 0.790 8.8
Y
ALM 480V 9.9 43.0 17.0 485 75.3 2,200 103 41.0 9,000 52.0 20 0.900 0.790 8.7

BLM/SLM 480V 9.0 43.0 17.0 453 68.5 2,000 103 41.0 9,000 52.0 20 0.911 0.780 8.7

Mechanical data External fan


Motor type Squirrel cage asynchronous motor Max. power consumption
Shaft height 100 3 AC 400 V / 50 Hz (±10%) 0.10 A
Cooling Forced ventilation DE -> NDE 3 AC 400 V / 60 Hz (±10%) 0.08 A
Vibration severity grade SPECIAL/B 3 AC 480 V / 60 Hz (±10%) 0.11 A
Shaft and flange accuracy SPECIAL

Degree of protection IP55


1)
Design acc. to Code I IM B5 (IM V1, IM V3) at a rated frequency of 4 kHz and a speed range of up to 5000 rpm

Pt1000 temperature sensor in the


Temperature monitoring stator winding

Color Standard (Anthracite RAL 7016)

Type of the bearing Performance

Shaft end Smooth hollow shaft

Incremental encoder sin/cos 1Vpp 256


Encoder system S/R without ND-end at terminal box
(encoder IN256S/R)

Physical constants
Thermal time constant 20 min

Moment of inertia 252 kgcm²

Weight (approx.) 65 kg

Connection
Type of electrical connection Terminal box

Position of the connection NDE top

Power connection NDE

Signal connection left

Terminal box designation gk813

Cooling data and sound pressure level


Airflow, min. 0.04 m³/s

Sound pressure level LpA(1m) motor +


external fan operation 50 HZ rated 70 dB 1)
load, tolerance + 3dB

Air discharge axial

Pressure drop 110 Pa

Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 1 Generated Wed Oct 23 00:26:41 CET 2024