Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Electronic Moisture Balance: Specifications Peripherals, Accessories

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

C054-E053B

Electronic Moisture Balance

Specifications Peripherals, Accessories

Model P/N MOC-120H 321-63300-10) Electronic Printer (w/o AC adapter) 321-64125


Measuring method Heat drying and weight loss AC Adapter for Electronic Printer 120V 321-63306-05
AC Adapter for Electronic Printer 230V 321-63306-04
Sample pan size 130 mm dia
GLP/GMP/ISO conforming calibration
Minimum display in weighing 0.001n
report can be produced.
Measurement range of
0.01% to 100.00 %
Intermediate status and final
moisture content results of measurements can be
Moisture content minimum display 0.01% printed out graphically.
Sample capacity 120n (321-64125 Includes connection cable,
printer paper 1 roll. AC Adapter should
Automatic or Timed ending modes, be separately ordered.)
Measurement modes Standard, Rapid, Slow and Step drying
modes, Predictive Measuring mode
Temperature Calibration Kit 321-64130
Drying heater Mid-wave infrared quartz heater
For temperature calibration at sample position, with
Setting temperature range 30 to 200 ; by 1; increments calibration report
(Sample position temperature)
Dimensions 220W X 415D X 190H (mm) RS-232C cable 321-63308
Weight 4.5o For connecting with computer.
Operational temperature and Data can be sent without software (WindowsDirect).
humidity range 5 to 40 ;, 85% RH or lower

Power requirements AC100 to 120 / 220 to 240V, 640W maximum


Sample pan 2pcs, Sample pan handler 2pcs,
Consumables, Supplies
Standard accessories
Aluminum sheet 20pcs, Spoon, Spatula

Stored procedures 10 Aluminum sheet 500pcs 321-63320-02

Printer paper for optional electronic printer 10 rolls 321-63306-08

Appropriate samples Safety Precautions


Samples from which moisture or other components Read Instruction manual and understand before use
vaporize and cause no hazardous reaction under of this instrument.
heating Do not measure any samples which cause hazardous
reaction under heating.
This instrument becomes very hot during measurements.
* Microsoft, Windows, and Excel are registered trademarks of Microsoft Corporation.
Use proper care to avoid burns or fires.
* The contents of this catalog are subject to change without notice.

URL http://www.shimadzu.com/balance
SHIMADZU CORPORATION. International Marketing Division SHIMADZU DO BRASIL COMÉRCIO LTDA.
3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641 Fax. 81(3)3219-5710 Avenida Marqus de S‹o Vicente, 1771. Barra Funda CEP : 01139-003-S‹o Paulo-SP, Brasil
Cable Add.:SHIMADZU TOKYO Phone: (55)11-3611-1688 Fax. (55)11-3611-2209
SHIMADZU SCIENTIFIC INSTRUMENTS, INC. SHIMADZU (HONG KONG) LIMITED Large sample pan (130mm dia.) and capacity allows optimum sample surface area.
7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A. Suite 1028 Ocean Center, Harbour City, Tsim Sha Tsui, Kowloon HONG KONG
Phone: 1(410)381-1227 Fax. 1(410)381-1222 Toll Free: 1(800)477-1227
SHIMADZU DEUTSCHLAND GmbH
Phone: (852)2375-4979 Fax. (852)2199-7438
SHIMADZU INTERNATIONAL TRADING (SHANGHAI) Co., LTD. SHANGHAI OFFICE
Reliable UniBloc weighing mechanism and unique auto-taring function enable very accurate measurements.
Albert-Hahn-Strasse 6-10, D-47269 Duisburg, F.R. Germany Phone: 49(203)7687-0 Fax. 49(203)766625 24th Floor, Shanghai Xin Hualian Building, No.755 Huaihai Zhong Lu, Shanghai, China
SHIMADZU (ASIA PACIFIC) PTE LTD. Phone: 86-21-6472-8442 Fax. 86-21-6472-8648
16 Science Park Drive #01-01 Singapore Science Park, Singapore 118227, Republic of Singapore Overseas Offices
Phone: 65-6778 6280 Fax. 65-6779 2935 Istanbul, Moscow
SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY. LTD. 4595-03501-30ANS
Units F, 10-16 South Street Rydalmere N.S.W. 2116, Australia
Phone: 61(2)9684-4200 Fax. 61(2)9684-4055
Choice of measuring modes meets your application. Different forms of samples can be measured.
Ending modes
Most samples which vaporize only moisture and cause no
Automatic ending mode

Accurate moisture measurement with new


hazardous reaction under heating can be measured
Automatically ends measurement

Temperature

vaporization
Moisture
when moisture loss over the Moisture vaporization
previous 30 seconds becomes over 30 seconds

weight sensor smaller than specified percentage.


Timed ending mode
Automatic ending

Temperature

vaporization
Moisture
Automatically ends measurement
when the specified amount of
time has elapsed. Powder Particles Paste or liquid
Features
Set ending time
Alternate Drying modes
1 Large sample pan allows even a large Rapid drying mode Various materials can be measured.
First dries with the highest temperature

Temperature

vaporization
Moisture
amount of sample to be placed evenly in a for the specified period, then shifts to
thin layer. The result is accurate and fast the specified temperature shortening
measurements. measurement time.
Slow drying mode
Ending drying
2 Mid-wave infrared quartz heater provides Gently heats samples that

Temperature

vaporization
Moisture
effective drying without interference for a might solidify at the surface or
wide range of samples. Besides the
samples that reduce under Cereals Other foods Chemical resin
high temperature.
excellent drying performance, it offers a long
Step drying mode Cereal, starch, flour, noodles, brewed products, sea foods,
operational life of 20,000 to 30,000 hours.
Allows step by step change of meat products, spices, sweets, diary products, vegetable oil,

Temperature

Temperature
vaporization
Moisture
3 The internal precision weighing balance is drying conditions . This feature is soil, ore, cokes, glass, cement, chemicals fertilizer, paper,
useful when measuring samples that pulp, cotton, fibers.
engineered with a Shimadzu UniBloc cell. contain a large amount of water.
The mechanism provides excellent stability
Predictive measuring mode
and a long operational life against
With preparatory measurements of

Temperature

vaporization
Predicted moisture
repeated temperature changes. the sample, the final result is Meets demands of various industries and fields
predicted from the drying process,
4 Digital control allows a selection of saving time in repeated measurements. Pharmaceuticals, agriculture, food processing, textiles,
Predicted
measurement modes. 10 sets of measurement measurement time chemicals, fertilizer, paper, construction.
settings can be stored for quick recall. Select
one of the 9 combinations of drying and Bar graph display monitors moisture vaporization
halting modes to optimize the measurement Bar graph display What is moisture
of your sample. vaporization rate display
In drying by infrared heater, a large
5 Weight loss rate in the previous thirty amount of moisture vaporizes in
Figure 1 early stage and vaporization slows
seconds is monitored and visually
towards the end of measurement.
presented in the bar graph display. This Vaporized moisture and
The M curve in Figure 2 shows a
feature is especially useful to show that the
vaporization rate
typical vaporization of moisture.

vaporization rate: M
Moisture

Vaporized
moisture: M
measurement is close to completion. M indicates the rate of vaporization.
Monitoring M makes it possible to
6 Shimadzu’s unique WindowsDirect function t(time) gauge how close the measurement is
Figure 2 to completion. The bar graph
is standard. Measurement data can be sent display makes it visible. (Figure 1)
to an application such as Excel® without
any software installation to the computer. Data out put with the optional printer
All you need to add is an RS232C cable. Example of print out in the graph output mode
7 A larger sample pan contributes to Maker :SHIMADZU CORP
Model :MOC-120H
Serial number :D207300000
accurate measurements, but the larger Device ID :ABCD-123
Sample code :B-20
heat capacity normally produces larger Date & time of measurement:2003/08/08,15:07
Measuring conditions storage area number:0
zero drift due to temperature fluctuation. Measurement standard:Dry base
Measurement mode:Preparatory(comparative) measuring mode
The MOC-120H is equipped with a unique Drying temperature setting:110:
Automatic ending condition:0.05%
auto-taring mechanism, which adjusts the Predicted value convergence range:0.5
Wet Mass :5.6892g
zero drift automatically and ensures high
accuracy, even with a larger sample pan.
Elapsed measuring time
8 Bias function allows adjustment to the data Changes in drying temperature
Measured value(%)
obtained by other measuring methods or
other testers.
Predicted measurement
9 Large backlit LCD is easily read even
under poor lighting conditions.
Dry Mass :4.8637g

You might also like