Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Ground Floor: Legend& Symbols

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

P04-MPW-02B0-10201 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

R R

Q Q

GENERAL NOTES :-
1- ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE MENTIONED.
2- COLD & HOT WATER PIPES MATERIAL IS PP-R PN-20.
P 3- ALL EXPOSED PIPES TO BE UV COATED AGANIST SUN RAYS. P
4- THERMOSTATIC MIXING VALVES MUST BE INSTALLED ON THE HOT
WATER SUPPLY BRANCH FOR EACH TOILET.
5- HOT WATER SUPPLY AND RETURN PIPES SHALL BE
THERMALLY INSULATED.
6- ALL MAIN WATER PIPES ARE ROUTED ABOVE FALSE CEILING
AND IN SHAFTS.
7- DRAWINGS ARE TYPICAL FOR BUILDINGS: P1.4 (2&9)

LEGEND& SYMBOLS:-
N N
AAV AUTOMATIC AIR VENT

LAV LAVATORY
KS KITCHEN SINK

SH SHOWER

CW COLD WATER
M HW HOT WATER M
CWP, HWP, HWRP U/G
TO BE CONNECTED TO
EXTERNAL WATER NETWORKS PPR POLYPROPYLENE

HDPE HIGH DENSITY POLYETHYLENE


90mm CWP UP TO H/L
75mm HWP UP TO H/L WHA WATER HAMMER ARRESTOR
40mm HWRP DN TO U/G

AFF ABOVE FINISH FLOOR

H.B HOSE BIBB


L 40mm HWRR F/A L
DN DOWN
© This drawing and the design it covers are the property of PGESCO.They are merely loaned and on the borrower's express agreement that they will not be reproduced, copied, loaned, exhibited, or used except in the limited way and private use permitted by any written consent given by the lender to the borrower.

32mm CWR T/A


32mm CWP H/L
R-17 32mm HWR T/A
25mm HWP H/L
F/A FROM ABOVE
32mm CWP H/L
20mm HWP H/L T/B TO BELOW
25mm CWP 40mm CWP
32mm CWP
25mm HWP 32mm HWP
25mm HWP
T/A TO ABOVE
32mm CWR T/A 40mm CWR T/A
R-16
32mm HWR T/A 32mm HWR T/A R-15
IV ISOLATION VALVE
40mm CWP
K 32mm HWP
CV CHECK VALVE K
75mm CWP
63mm HWP BL.V BALANCING VALVE
75mm CWP CWR COLD WATER RISER
63mm HWP 40mm CWP
32mm HWP
R-14 CWP COLD WATER PIPE
50mm CWR T/A
40mm HWR T/A
32mm CWR T/A R-13 HWR HOT WATER RISER
32mm HWR T/A
32mm CWR T/A R-12 HWP HOT WATER PIPE
J 32mm HWR T/A J
HWRR HOT WATER RETURN RISER
75mm CWP
40mm CWP 63mm HWP
32mm HWP HWRP HOT WATER RETURN PIPE
40mm CWP
32mm CWP 32mm HWP
25mm HWP R-05 L/L LOW LEVEL
32mm CWR T/A
32mm HWR T/A
50mm CWP
40mm HWP 32mm CWP
H/L HIGH LEVEL
25mm HWP
75mm CWP
63mm HWP 32mm CWR T/A
R-01 U/T UNDER TILES
63mm CWP 32mm HWR T/A
H 50mm CWP 63mm HWP
U/G UNDERGROUND H
40mm HWP
40mm CWP
40mm CWP
40mm HWP
32mm HWP IW IN WALL
63mm CWP 40mm CWP
50mm CWP 63mm HWP 32mm HWP W.M WASHING MACHINE
50mm HWP 40mm CWP
25mm CWP 32mm HWP
25mm HWP 50mm CWP
50mm CWR T/A
D.W DISH WASHER
32mm CWR T/A 63mm CWP 40mm CWP 40mm HWP R-03
R-11 63mm HWP 32mm HWP 63mm CWP 40mm HWR T/A 50mm CWP 40mm CWP
32mm HWR T/A 50mm HWP 50mm CWP 40mm HWP
32mm CWR T/A R-09 32mm CWR T/A R-06 32mm HWP
40mm CWP 40mm HWP
40mm CWR T/A 32mm HWR T/A 32mm HWP 32mm HWR T/A
R-10
40mm HWR T/A
32mm CWP
G 25mm HWP G
40mm CWP
32mm HWP

40mm CWR T/A 32mm CWR T/A 32mm CWR T/A


25mm CWP 32mm HWR T/A R-08 32mm HWR T/A R-07 32mm HWR T/A R-02
25mm HWP
50mm CWR T/A R-04
32mm CWP
40mm HWR T/A
25mm HWP
25mm CWP 25mm CWP
25mm HWP 25mm HWP

F F

REFRENCES:-
E E

D Ground Floor 1
08
05
24
ISSUED FOR USE MA AS HA HA
D

01
07 ISSUED FOR BID MA AS HA HA
0
24

NO. DATE REVISIONS BY DES ENGR. PROJ APPR


CHK SUPV ENGR
DRAWN CHIEF
SCALE 1:100 DATE AUG. 2024 DESIGNED MA MA ENGR

ENGINEERING AUTHORITY OF
C THE ARMED FORCES C
ELECTRO MECHANICAL CONSULTANT:

PGESCO
Integrated Innovative Engineering

CONTRACTOR:

B B
PROJECT:

EL ALAMIN COMPLEX
PARCEL 1.4- TYPE 2 B

WATER SUPPLY SYSTEM DESIGN


PGESCO CONFIDENTIAL
GROUND FLOOR PLAN
A © PGESCO 2023. Contains confidential and/or proprietary JOB NO DWG NO REV A
information to PGESCO Which shall not be used, disclosed
or reproduced in any format by any non-PGESCO party
without PGESCO's prior written permission. All rights reserved. 10218 P04-MPW-02B0-10201 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 841 X 1189 "A0" SIZE