Frequency (HZ) : Parts Layout

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

1 2 3 4 5 6 7 8 9 10

51 mm

[2"]

2438 mm

[8'] 19 mm

648 mm [3/4"]

A [2'-1 1/2"] SIDES (4) A

POLYESTER
DACRON
152 mm
A-A (1:8)
A [6"]

206
610 mm
51 mm
[2']
[2"]

B
19 mm B

[3/4"]

TOP, BOTTOM, & BRACES (7)

[3'-11 5/8"]
51 mm
2438 mm

1210 mm
[8']

[2"] 51 mm

[2"]
SIDE & CORNER BLOCKING (10)

C 19 mm C

[3/4"]

tel: +62 21 295 734 88 / +62 821 7777 1978


Architectural Acoustics
Performance Hall, &
1219 mm

Recording Studio,
[4']

Consultants
145 mm
EFFECTIVE RESPONSE AT 0 DEGREE INCIDENCE
[5 11/16"]

web site: http://www.jhbrandt.net


6 mm
[2'-0 3/16"]
614 mm

[1/4"]

Summarecon Bekasi, Cluster Lotus, IA 20


ISOMETRIC CUT-AWAY VIEW
BRANDT

Absorption Coefficient
6 mm

JH
0.8

Bekasi, West Java, Indonesia


email: john@jhbrandt.net
[1/4"]
0.7
ISOMETRIC VIEW
D D
0.6
A
LIGHTWEIGHT
FIBERGLASS
INSULATION THIS DRAWING IS PROPERTY OF

JH
Recording Studio,

BRANDT
Performance Hall, &
0.4
*Owens Corning R19 - R31, or similar. 10 - 15 kg/m3 density Architectural Acoustics
Consultants
AND AS AN INSTRUMENT OF
SERVICE, MAY NOT BE ALTERED,
REPRODUCED, COPIED OR USED
FOR CONSTRUCTION WITHOUT
THE WRITTEN PERMISSION OF
0.2 JH BRANDT.
© 2020 all rights reserved.

Drafter : Date :
John H. Brandt 05/25/2020

Drafter : Date :

0
20 50 100 200 500 1000 2000 5000 10000 20000 Drafter : Date :

Frequency (Hz) Revision/Issue : Date :

Revision/Issue : Date :

This drawing is to be printed on Scale Metric:


standard A1 paper: 594 mm X 841 mm
-if not, DO NOT SCALE-
1:8

E
PARTS LAYOUT E

Job No : Project Date:


10864 05/25/2020

Sheet :

LIGHTWEIGHT POLYESTER
FIBERGLASS
INSULATION
DACRON
RIGID
FIBERGLASS 1 2 of

1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10

SIDE & CORNER BLOCKING

A A

206
B B
SIDES

POLYESTER /
DACRON
TOP, BOTTOM,
& BRACES

1. ASSEMBLE TOP, BOTTOM, AND SIDES 2. ATTACH FABRIC TO THE INSIDE OF THE 3. INSTALL CENTER BRACES & SLATS AND 4. FILL WITH LIGHTWEIGHT FIBERGLASS
USING DOWELS AND GLUE. MAKE SURE FRAME USING UPHOLSTERERS TAPE OR ADD 41" (6 mm) DACRON / POLYESTER
THE THE UNIT IS 'SQUARE' (90 DEGREE THIN STRIPS OF PLYWOOD. BATTING AGAINST FRONT FABRIC
C
CORNERS). C

tel: +62 21 295 734 88 / +62 821 7777 1978


Architectural Acoustics
Performance Hall, &
Recording Studio,
6. COVER THE BACK OF THE UNIT WITH

Consultants
INEXPENSIVE TICKING FABRIC TO KEEP
THE COMPONENTS STABLE DURING
5. ADD REAR BRACING
SHIPPING AND INSTALLATION.

web site: http://www.jhbrandt.net


Summarecon Bekasi, Cluster Lotus, IA 20
BRANDT

JH Bekasi, West Java, Indonesia


email: john@jhbrandt.net
SEE: Side-Panel Clamps and Doweling.pdf
D D
SLATS (9)

THIS DRAWING IS PROPERTY OF

JH
Recording Studio,

BRANDT
Performance Hall, &
Architectural Acoustics
Consultants
AND AS AN INSTRUMENT OF
SERVICE, MAY NOT BE ALTERED,
REPRODUCED, COPIED OR USED
FOR CONSTRUCTION WITHOUT
THE WRITTEN PERMISSION OF
JH BRANDT.
© 2020 all rights reserved.

2432 mm Drafter : Date :


John H. Brandt 05/25/2020
51 mm
[7'-11 3/4"] Drafter : Date :

[2"] Drafter : Date :

Revision/Issue : Date :

Revision/Issue : Date :

19 mm This drawing is to be printed on Scale Metric:


standard A1 paper: 594 mm X 841 mm
-if not, DO NOT SCALE-
1:8

[3/4"]
E
ASSEMBLY E

Job No : Project Date:


10864 05/25/2020

Sheet :

ALL TREATMENT IS ASSEMBLED USING DOWEL AND GLUE METHOD


2 2 of

1 2 3 4 5 6 7 8 9 10

You might also like