AE615

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

SHEET NO. CLUSTER FACILITY ZONE PROJECT NO.

Ministry Of Housing ,Utilities &Urban


Communities
R R

New Urban Communities Authority


W:\2550\A-ARCHITECTURAL\CAD\XREF\SHARE\SUBMISSION\GENERAL PACKAGE 28-04\BIND\AE615

Q Q

CONSULTANT:

www.ecgsa. com
P P

KEY PLAN

N N

GRC PIER DETAIL GRC PIER DETAIL GRC PIER DETAIL GRC PIER DETAIL REMARKS:
01 02 03 04 · ALL DIMENSIONS ARE METRIC (IN mm)
· FFL = FINISH FLOOR LEVEL
M M
· TOC = TOP OF CONCRETE
· TOPR = TOP OF PARAPET

NOTES:
· ALL DIMENSIONS TO BE VERIFIED ON SITE AND APPROVED BY THE ENGINEER
· ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND
ALL RELEVANT SECTIONS OF THE SPECIFICATIONS
· FOR THE STRUCTURE ELEMENTS SUPPORTING MASONRY WORKS REFER TO STRUCTURE
L DRAWINGS. L
· SHOP DRAWINGS FOR THE COORDINATED OPENINGS SHOULD BE SUBMITTED TO THE
AUTHORIZED ENGINEER FOR APPROVAL.
· JUNCTIONS BETWEEN REINFORCED CONCRETE AND BLOCK WORKS SHOULD BE TREATED BY
METAL LATH PRIOR TO APPLYING PLASTER.
· DETAILS OF FIXATION SHOWN ON THIS DRAWING ANCHORAGES, BOLTS, PINS, SCREWS, ETC… ARE
INDICATIVE. CONTRACTOR SHOULD SUBMIT SHOP DRAWINGS AND CALCULATION SHEETS FOR
APPROVAL.
· ALL FACADE LIGHTING FIXATION DETAILS SHOULD BE CONSIDERED IN GRC SHOP DRAWINGS. STRIP
LIGHTING SHOULD BE RECESSED IN GRC PROFILES.
K · ALL GRC COLORS SHOULD MATCH EACH BUILDING COLOR SCHEME. K

J J

H H

GRC PIER DETAIL GRC PIER DETAIL GRC PIER DETAIL GRC PIER DETAIL
05 06 07 08
G G

F F
April 22,
Monday, November
Wednesday, 2020
19, PM
5:42:41
3:21:29
2018 PM

E E
Sheet size - ISO A0 (841* 1189 mm)

D D

C REV DATE ISSUED FOR DRW CHK TL PM C


100 mm

PROJECT DATA:

DISCIPLINE

B B
50 mm

SHEET TYPE
Scanning scale

SHEET TITLE

GRC PIER DETAIL GRC PIER DETAIL GRC PIER DETAIL


09 10 11
SCALE PROJECT NO. ZONE CLUSTER FACILITY SHEET NO. REFERENCES REV.
10 mm

A A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ECG Copyright
THIS DRAWING AND THE DESIGN IT COVERS ARE THE PROPERTY OF THE ENGINEERING CONSULTANTS GROUP .THEY ARE MERELY LOANED ON THE BORROWER'S EXPRESSED AGREEMENT THAT THEY WILL NOT BE REPRODUCED, COPIED, LOANED, EXHIBITED NOR USED EXCEPT FOR LIMITED AND PRIVATE USE PERMITTED BY WRITTEN CONSENT GIVEN BY THE LENDER TO THE BORROWER.