BMS Series

High speed response type with built-in output protection circuit


Features
● Reverse power polarity and overcurrent
● High speed response : Max. 1ms
● Light ON/Dark ON mode selectable by control wire
● Built-in the sensitivity adjustment VR
(Except for through-beam type)

Please read “Caution for your safety” in operation (MS-2) (MS-5)


manual before using. ※ MS-5 is sold separately.

Specifications
NPN open collector output BMS5M-TDT BMS2M-MDT BMS300-DDT
Model
PNP open collector output BMS5M-TDT-P BMS2M-MDT-P BMS300-DDT-P
Sensing type Through-beam Retroreflective Diffuse reflective
※1 ※2
Sensing distance 5m 0.1 to 2m 300mm
Sensing target Opaque materials of Min. ø10mm Opaque materials of Min. ø60mm Translucent, Opaque materials
Hysteresis - Max. 20% at rated settingdistance
Response time Max. 1ms
Power supply 12-24VDC ±10%(Ripple P-P : Max. 10%)
Current consumption Max. 50mA Max. 45mA
Light source Infrared LED(940nm)
Sensitivity adjustment - Adjustable VR
Response time Selectable Light ON or Dark ON by control wire
NPN or PNP open collector output
Control output ●Load voltage : Max. 30VDC ●Load current : Max. 200mA
●Residual voltage - NPN : Max. 1V, PNP : Max. 2.5V
Protection circuit Reverse power polarity, Output short-circuit(Overcurrent) protection circuit
Indicator Operation indicator : Red LED, Power indicator : Red LED(BMS5M-TDT1)
Insulation resistance Min. 20MΩ(at 500VDC megger)
Noise resistance ±240V the square wave noise(pulse width : 1㎲) by the noise simulator
Dielectric strength 1000VAC 50/60Hz for 1minute
Vibration 1.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Shock 500m/s²(50G) in each of X, Y, Z directions for 3 times
Ambient illumination
Sunlight : Max. 11,000㏓, Incandescent lamp : Max. 3,000㏓
Environ-
Ambient temperature -10 to 60℃, storage : -25 to 70℃
ment
Ambient humidity 35 to 85%RH, storage : 35 to 85%RH
Material Case : ABS, Sensing part : Acryl (Through-beam : PC)
ø5mm, 4-wire, Length : 2m(Emitter of through-beam type: ø5mm, 2-wire, Length : 2m)
Cable
(AWG22, Core diameter : 0.08mm, Numner of cores : 60, Insulator out diameter : ø1.25mm)
Reflector(MS-2),
Individual - VR adjustment driver
Accessories VR adjustment driver
Common Mounting bracket, Bolts/nuts
Approval
Unit weight Approx. 180g Approx. 110g Approx. 100g

※1: It is mounting distance between sensor and reflector MS-2 and it is same when MS-5 is used. It is detectable under 0.1m.
※2: It is for Non-glossy white paper(100×100mm)
※ The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.

A-40
Amplifier Built-in type by Side Sensing

Feature data (A)


Photo
electric

Through-beam type sensor

(B)
● BMS5M-TDT ● BMS5M-TDT-P Fiber
optic
sensor
Parallel shifting characteristic Angle characteristic
(C)
Measuring method Data Measuring method Data Door/Area
sensor

(D)
Receiver Receiver Proximity
sensor
5 5

Sensing distance L(m)


Sensing distance L(m)

(E)
3 3 Pressure
ℓ1 θ
sensor
L
L
1 1 (F)
Rotary
encoder

0 0
Emitter 400 200 0 200 400
Emitter 40° 20° 0 20° 40° (G)
ℓ1 ℓ1 Connector/
Left Center Right Socket
Left Center Right
Operation angle θ
Sensing area(mm) (H)
Temp.
controller

Retroreflective type (I)


SSR/
Power
● BMS2M-MDT ● BMS2M-MDT-P controller

Parallel shifting characteristic Sensor angle characteristic (J)


Counter

Measuring method Data Measuring method Data


(K)
Timer
Reflector(MS-2)
Reflector(MS-2)
Sensing distance L(m)

(L)
Sensing distance L(m)

2 2 Panel
meter

ℓ1 L
L (M)
θ Tacho/
1 1 Speed/ Pulse
meter

(N)
0 Display
unit
Reflective 120 60 0 60 120 0
Reflective 40° 20° 0 20° 40°
ℓ1 ℓ1
Left Center Right (O)
Left Center Right Sensor
Operation angle θ controller
Sensing area(mm)

(P)
Switching
power
Retroreflective type Diffuse reflective type supply

(Q)
● BMS2M-MDT ● BMS2M-MDT-P ● BMS300-DDT ● BMS300-DDT-P Stepping
motor&
Driver&Controller
Reflector angle characteristic Sensing area characteristic
(R)
Measuring method Data Measuring method Data Graphic/
Logic
panel

(S)
Reflector(MS-2) Standard sensing target: Field
Non-glossy white paper 400 network
device
100×100mm
Sensing distance L(mm)

2 300
Sensing distance L(m)

ℓ1
(T)
Software
θ L 200
1
L 100 (U)
Other

0
0 20 10 0 10 20
40° 20° 0 20 40° ℓ1 ℓ1
Reflective Center
Diffuse reflective
Left Right Left Center Right
Operation angle θ Sensing area(mm)

A-41
BMS Series

Control output diagram


● NPN open collector output ● PNP open collector output
Photoelectric sensor circuit Connection Photoelectric sensor circuit Connection
(Brown)+V (Brown)+V
(Dark ON) (Dark ON)
Load 1.5Ω
(Black)Output
Overcurrent 39V Ma. 200mA
protection
Main circuit

Main circuit
39V Max. 200mA 12-24VDC±10% (Black)Output +
Overcurrent - 12-24VDC±10%
protection -
1.5Ω (Blue)0V (Light ON)
Load
(Light ON)
(Blue)0V

10kΩ 10kΩ (White)Control


(White)Control

Through-beam: BMS5M-TDT2, Retroreflective: BMS2M-MDT Through-beam: BMS5M-TDT2-P, Retroreflective: BMS2M-MDT-P


Diffuse reflective: BMS300-DDT Diffuse reflective : BMS300-DDT-P
※ Select Light ON / Dark ON by control wire. - Light ON : Connect control wire to 0V / Dark ON : Connect control wire to +V

Operation mode
Operation mode Light ON Dark ON
Received light Received light
Receiver operation
Interrupted light Interrupted light
Operation indicator ON ON
(Red LED) OFF OFF
ON ON
Transistor output
OFF OFF

Connections
BMS5M-TDT, BMS5M-TDT-P BMS2M-MDT, BMS2M-MDT-P BMS300-DDT, BMS300-DDT-P
Emitter Receiver Operation indicator
Power indicatot Operation indicator Operation indicator

Reflector Sensing
(MS-2) target
Sensing
target Sensing
target

Brown Brown Brown


Brown
(Dark ON) (Dark ON) (Dark ON)
Load ① Load ① ①
+ 12-24VDC Black + 12-24VDC Black + 12-24VDC Black Load + 12-24VDC
- ±10% - ±10% - ±10% - ±10%
Blue
Blue Load ② Blue Load

Blue
Load ②
(Light ON) White(Control) (Light ON) White(Control) (Light ON)
White(Control)
①Load connection for NPN output ①Load connection for NPN output ①Load connection for NPN output
②Load connection for PNP output ②Load connection for PNP output ②Load connection for PNP output

※ Dark ON mode is on when control line is opened.

Dimensions ● Connect the bracket


Adjustment VR
(Except for
through-beam type)
36.4
21

Operation indicator 22.5 M4 Bolt


16 Optical axis 29 (Power indicator Optical axis 29
in emitter)
55
38.5

63
51.5
5.5

Cable : ø5, 2m
7.5 15
(unit: mm)

A-42
Amplifier Built-in type by Side Sensing
● Reflector ● Bracket 2-ø4.2 (A)
Photo
electric

13
< MS-2 > < MS-5 >

20.4
sensor

2-ø2.2 (B)
Fiber
optic
20

20.5
sensor

24
60.5
52

5 (C)
12 2 R1 Door/Area
sensor

10°
15.4 7.5

20.4
1.6
(D)
2-ø3.8

13

30°
34 2.5 Proximity
sensor
40.5 5
8.5
(E)
25 Pressure
sensor

(F)
Mounting and sensitivity adjustment Rotary
encoder

Install the sensor to the desired place and check the connections.
(G)
Supply the power to the sensor and adjust the optical axis and the sensitivity as follow ; Connector/
Socket

Optical axis adjustment Sensitivity adjustment


(H)
● Through-beam type ● Retroreflective type Temp.
controller
Set the photoelectric sensor in the middle of the operation Fix the adjustment VR at max.position and then check if the
(I)
range of the operation indicator adjusting the receiver or sensor operates normally to pass the target within sensing SSR/
Power
emitter right and left, up and down. area of the sensor. controller
If the sensor does not work normally by noise or external
shine, turn the adjustment VR slowly up to the position. (J)
Counter
Adjust ※If reflectance of target is higher than non-glossy
Right/Left Receiver white paper, it might cause malfunction by reflection from
(K)
xis the target when the target is near to the photoelectric
ic al a Timer
Opt sensor. Therefore enough space between the target
Emitter should be used and the photoelectric sensor or the (L)
Panel
surface of the target should be mounted at angle of 30° meter
Adjust Up/Down
to 45° against optical axis.
(M)
● Retroreflective type Tacho/
Speed/ Pulse
● Retroreflective type Mount the photoelectric sensor and the reflector face each
meter

Mount the photoelectric sensor and the reflector face each other then fix them in the middle of operation range of the (N)
other then fix them in the middle of operation range of the operation indicator adjusting the reflector right and left, up
Display
unit
operation indicator adjusting the reflector right and left, up and down.
and down. Reflector (O)
Sensor
30 to 45° (MS-2) controller

Adjust Reflector (P)


Switching
Right/Left (MS-2) power
supply
Photoelectric Sensing target <MS-5>
sensor
al axis (Q)
O ptic ※ If the mounting place is too narrow, please use MS-5 Stepping
motor&
instead of MS-2. Driver&Controller
Adjust Up/Down
● Diffuse reflective type (R)
Graphic/
Logic
Set the target at a position to be panel
detected by the beam, then turn ⓐ
● Diffuse reflective type the adjustment VR until position
Optimal (S)
Field
position network
Mount the photoelectric sensor and the target then fix them ⓐ where the operation indicator device
in the middle of operation range of the operation indicator turns ON from min. position of
adjusting the photoelectric sensor right and left, up and the adjustment VR up to position (T)
Software
down. ⓐ which the operation indicator ⓑ
MIN. MAX.
turn ON from min. SENS (U)
Ta k e t h e t a r g e t o u t o f t h e Other
Photoelectric sensing area, then turn the adjustment VR until position
sensor
Sensing
where the indicator turns ON.
target If position ⓑ is not checked, the max.position is ⓑ. Set the
adjustment VR in the middle of two switching position ⓐ, ⓑ.
※ Please be aware not to make the unstable operation of
sensor by background and mounting side.

A-43