Timers - DELTA PRO series P6SE

ON delay
1 Time range
1 Supply voltage
1 change-over contact
Width 22.5 mm
Industrial design

Technical data
1. Functions Mechanical life: 10 x 106 operations
E ON delay Electrical life: 1 x 105 operations
at 1000VA resistive load
2. Time ranges Switching frequency: max. 60/min at 100VA resistive load
s. table max. 6/min at 1000VA resistive load
(according to IEC 947-5-1)
Insulation voltage: 250V AC (according to IEC 664-1)
3. Indicators Surge voltage: 4kV, overvoltage category III
Green LED ON: indication of supply voltage (according to IEC 664-1)
Yellow LED ON/OFF: indication of relay output
7. Accuracy
Subject to alterations and errors

4. Mechanical design Base accuracy: ±5% (of maximum scale value)


Self-extinguishing plastic housing,IP rating IP40 Adjustment accuracy: ≤5% (of maximum scale value)
Mounted on DIN-Rail TS 35 according to EN 50022 Repetition accuracy: <1%
Mounting position: any Voltage influence: –
Shockproof terminal connection according to VBG 4 Temperature influence: ≤0.1%/°C
(PZ1 required), IP rating IP20
Initial torque: max. 1Nm
Terminal capacity: 8. Ambient conditions
1 x 0.5 to 2.5mm2 with/without multicore cable end Ambient temperature: -25 to+55°C (according to IEC 8-1)
2 x 0.5 to 1.5mm2 with/without multicore cable end -25 to+40°C (according to UL 508)
2 x 1.5mm2 flexible without multicore cable end Storage temperature: -25 to+70°C
Transport temperature: -25 to+70°C
Relative humidity: 15% to 85%
5. Input circuit (according to IEC 721-3-3 class 3K3)
Supply voltages (availability see table): Pollution degree: 3 (according to IEC 664-1)
24V AC/DC terminals A1(+)-A2 (P6SE 24VAC/DC))
42V AC/DC terminals A1(+)-A2 (P6SE 42VAC/DC) 9. Types
48V AC/DC terminals A1(+)-A2 (P6SE 48VAC/DC)
110V AC terminals A1-A2 (P6SE 110VAC)
230V AC terminals A1-A2 (P6SE 230VAC)) Time ranges
Tolerance: 1s 3s 10s 30s 1min 10min 30min 1h
24V DC ±10% (P6SE 24VAC/DC)
24V AC -15% to+10% 24V
AC/DC
X X
42V DC ±10% (P6SE 42VAC/DC)
42V AC -15% to+10% 42V
Supply voltages

48V DC ±10% (P6SE 48VAC/DC) AC/DC


48V AC -15% to+10%
110V AC -15% to+10% (P6SE 110VAC) 48V
AC/DC
X
230V AC -15% to+10% (P6SE 230VAC)
Rated frequency: 48 to 63Hz 110V
Rated consumption: AC
X
24V AC/DC 1VA (0.6W) (P6SE 24VAC/DC)
42V AC/DC 1,5VA (1W) (P6SE 42VAC/DC) 230V
AC
X X X X X
48V AC/DC 1,7VA (1,2W) (P6SE 48VAC/DC)
110V AC 4VA (1.3W) (P6SE 110VAC)
230V AC 8VA (1.3W) (P6SE 230VAC) All marked types are standard types.
Duration of operation: 100% Not marked types only on request (Minimum quantity for an order).
Reset time: 100ms type code:
Residual ripple for DC: 10% P6SE + "supply voltage" + "time range" (e.g.. P6SE 230VAC 10s)
Drop-out voltage: >20% of the supply voltage

6. Output circuit
1 potential free change-over contact
Switching capacity (distance < 5mm): 750VA (3A/250V AC)
Switching capacity (distance > 5mm):^ 1250VA (5A/250V AC)
Fusing: 6A fast acting

Release 07/05 3.03-2


P6SE

Functions
ON delay (E)
When the supply voltage U is applied, the set interval t begins (green
LED flashing). After the interval t has expired (green LED illuminated)
the output relay R switches into on-position (yellow LED illuminated).
This status remains until the supply voltage is interrupted.
If the supply voltage is interrupted before the expiry of the interval t,
the interval already expired is erased and is restarted when the supply
voltage is next applied.

Connections

Subject to alterations and errors


Dimensions