CD Automation CD1800 - User manual

CD1800 DIGITAL INDICATOR

CD1800 Digital Indicator is a panel


mounting instrument designed to have a
digital indication of low and hight DC
voltage inputs.
3½ Digit display (1999) with automatic
sign indication.
18 0 0 Precision is 0.1% ± 1Digit.

APPLICATION
The most common application are:
n RPM indication from tacho signal
n Current indication with signal from
DC-Drive/Inverter
n Speed indication from tacho signal
or from DC-Drive/Inverter
n Pull indication from a load cell
n Position indication from linear

1999 transducer
48

n Digital voltmeter
AUTOMATION
CD-1800
MAIN FEATURES
n Very competitive price
96
n Hight efficiency 3½ digit Display.
n Stick on lables for Engineering
units
n Internal power supply for linear
transducer +5 -5V
44

48

n Three wires potentiometer input


with zero position tuning capability
n Inputs and decimal points
adjustable via jumpers
9 8 75 9

92 DIMENSION
Frontal dimension: 48x96mm
Depth: 83mm
Panel cutout: 45x92mm
Cas material: Noryl UL 94 V-O auto
45

extinguishing
Weight: 300grams.
CD Automation CD1800 - User manual

TECHNICAL DATA

Input type 0-5 Vdc Impedance >100 Kohm


0-10 Vdc Impedance >100 Kohm
0-100 Vdc Impedance >100 Kohm
0-200 Vdc Impedance >100 Kohm
4-20 mA Impedance =250 Ohm
Precision ± 0,1% f.s. ±1 digit
Repeatability ± 0,1% f.s.
Scale range ± 1999 3½ digit
Voltage supply 115-230 Vac ±10%
Consumption 3 VA
Thermal drift ± 200 ppm/°C
Display LED 7 segments 13 mm
Decimal point position Dip switch selectable
Zero adjust ± 150 digit
Span adjust 50%÷150% span
Linear transducer voltage supply+ 5 V - 5 V 10mA max
Working temperature 0÷ +45 °C (U.R.<90%)
Stocking temperature 0÷ +60 °C (U.R.<90%)
Wiring connection Screw terminals
Protection IP 30
Case material Auto extinguishing Noryl UL 94 V-O
Weight 300 grams

INPUT SELECTION VIA BANK SWITCH BS1

BS1 The indicator is supplied pre-configured


to the order code.
J5 J4 J3 J2 J1
Re-configuration of inputs is easy
archived by the user following the below
instructions.
J5 closed 0÷ 5Vdc
J4 closed 0÷ 10Vdc
Rc J3 closed 0÷100Vdc
J2 closed 0÷200Vdc
J1 closed 4÷ 20mA

When input 4÷20mA has been chosed


mount RC=100Kohm
CD Automation CD1800 - User manual

ZERO SPAN TUNING

Remove the frontal flat display filter with


a small screwdriver and you will gain

1. 9.9.9.
access to tuning potentiometers for Zero
and Span scale.
Tune the span pot until to have the
desired full scale indication. After which
tune zero pot up to have Zero read out on
ZERO ZmA SPAN display. After which control again the
span indication.
When 4÷20mA has been used with 4mA
input adjust ZmA potentiometer to have
Zero read out.

DECIMAL POINT SELECTION VIA BANK SWITCH BS2

1.9.9.9.
J6 closed 1.999 read out
J7 closed 19.99 read out
J8 closed 199.9 read out

BS2 J9 closed 1999 3½ digit read out


J6 J7 J8 J9 J9 open 199 3 digit read out
DECIMAL SELECTION FOR
POINT POSITION 3 OR 3½ DIGIT READ OUT

WIRING CONNECTIONS

1 2 3 4 5 6 7 8
- + -5V +5V

115 Vac V
2,5-10K
230 Vac DT

Linear
mA
transducer
INPUT
CD Automation CD1800 - User manual

INDICATOR CODE
Code CD1800 /- - - - / - / M -
Model
Input type
Display colour
Manual type
MODEL
Digital indicator CD1800

INPUT TYPE
Code Description
0005 0-5 Vdc
0010 0-10 Vdc
0100 0-100 Vdc
0200 0-200 Vdc
0420 4-20 mA

OPTION
Code Description
R Red LED display
V Green LED display

TYPE MANUAL
Code Description
1 Italian manual
2 English manual

In normal operation, the operator must not remove the indicator from its housing
or have unrestridted acces to the rear terminals, as this would provide potential
contact with hazardous live parts.
Installation and configuration must be undertaken by technically competent
servicing personnel.

Comply with EMC specification, mark.

Controllers, Drives & Automation


CD Automation s.r.l.
via Picasso, 34/36
20025 Legnano (MI) - ITALIA
Tel. 0039-331-577479 Fax 0039-331-579479
E-MAIL: info@cdautomation.com
WEB:www.cdautomation.com
ENGINEERING UNITS

% % % % % %
bar bar bar bar bar bar
mbar mbar mbar mbar mbar mbar
3 3 3 3 3 3
m /h r m /h r m /h r m /h r m /h r m /h r
rpm rpm rpm rpm rpm rpm
ppm ppm ppm ppm ppm ppm
%RH %RH %RH %RH %RH %RH
psi psi psi psi psi psi
mV mV mV mV mV mV
V V V V V V
mA mA mA mA mA mA
A A A A A A
kW kW kW kW kW kW
W W W W W W
Kg Kg Kg Kg/s Kg/s Kg/s
Kg/h Kg/h Kg/h litres litres litres
l/s l/s l/s l/h l/h l/h
°F °F °F °F °F °F
°C °C °C °C °C °C
mt/s mt/s mt/s mt/min mt/min µ
Hz Hz Hz Hz Hz µ

Cut the engineering unity desired and insert it in the window on the front of the CD1800
ENGINEERING UNITS

% % % % % %
bar bar bar bar bar bar
mbar mbar mbar mbar mbar mbar
3 3 3 3 3 3
m /h r m /h r m /h r m /h r m /h r m /h r
rpm rpm rpm rpm rpm rpm
ppm ppm ppm ppm ppm ppm
%RH %RH %RH %RH %RH %RH
psi psi psi psi psi psi
mV mV mV mV mV mV
V V V V V V
mA mA mA mA mA mA
A A A A A A
kW kW kW kW kW kW
W W W W W W
Kg Kg Kg Kg/s Kg/s Kg/s
Kg/h Kg/h Kg/h litres litres litres
l/s l/s l/s l/h l/h l/h
°F °F °F °F °F °F
°C °C °C °C °C °C
mt/s mt/s mt/s mt/min mt/min µ
Hz Hz Hz Hz Hz µ

Cut the engineering unity desired and insert it in the window on the front of the CD1800