2- Proposed BOQ.
Submitted Item List
Application
Twisted pair cable suitable for High Speed Local Area Networks and
Analogue & Digital video applications
Conductor
Insulation
Cross Support
Al/PET Tape
Sheath
Rip Cord
Drain Wire
Design
Unit Properties
Conductor Solid Plain Copper Wire
Polyethylene
Pair 1: WHITE-Blue/Blue
Insulation Pair 2: WHITE-Orange/Orange
Pair 3: WHITE-Green/Green
Pair 4: WHITE-Brown/Brown
Pair Two wires twisted together
UTP No screen
Overall screen of Aluminium/Polyester
FTP
Foil with tinned copper drain wire
Each pair shielded with Aluminium /
U-FTP Polyester foil, with tinned copper drain
wire, no overall screen
Rip Cord Nylon Yarn
Polyvinyl Chloride (PVC)
Standard Color: Grey
or
Sheath Material
Halogen Free, Flame Retardant
(HFFR/LSZH)
Standard Color: Purple
Standard Put Up Length 305 Metres
*Other Colors, Put Up Lengths and structures can be manufactured upon request, please contact your local B3
International sales representative.
B3 International Page 1 of 3
info@b3cable.com – www.b3cable.com Rev: 1.1
Date: 30/05/2015
Datasheets are subject to change without notice
Category 6A Data Cables
Physical Characteristics
Part Number C1055 C1455 C1555 C1200 C1056 C1456 C1556 C1052 C1057 C1457 C1557 C1053
PVC PVC HFFR/ PVC PVC HFFR/ PVC PVC HFFR/
Sheath Material PVC PVC PVC
CM CMR LSZH CM CMR LSZH CM CMR LSZH
Screen type UTP FTP U-FTP
No. of Pairs 4
Conductor Size (AMG) 23
Drain Wire Size (AMG) - 26 26
Screen Coverage (%) - 115 115
Nom. Radial Thickness
0.5
Sheath (mm)
Nom. Overall Diameter
7.0 7.2 7.8
(mm)
Operating
-20°C to +60°C
Temperature (°C)
Min. Bend Radius
70 72 78
(install) (mm)
Maximum Pulling
160 200 210
Tension (Newton)
B3 International Page 2 of 3
info@b3cable.com – www.b3cable.com Rev: 1.1
Date: 30/05/2015
Datasheets are subject to change without notice
Category 6A Data Cables
Reference Standards
B3 International Page 3 of 3
info@b3cable.com – www.b3cable.com Rev: 1.1
Date: 30/05/2015
Datasheets are subject to change without notice
Fire Resistant Cables - Enhanced
Two core, Overall Screen, LSZH/HFFR Sheath
BS 6387 CWZ, EN 50200 PH120
C1044, C1045, C1283, C1284, C1289, C5126
Applications
Screened two core Fire Resistant cable for Building and Industrial Management
Systems
Conductor
Insulation
PET Tape
Al/PET Tape
PET Tape
Drain Wire
Sheath Appendix to Cert/LPCB ref. No. 1168a-(cl-1)/01
Design
Unit Properties
Conductor 2 x Solid or Flexible Bare Copper wire
Ceramifiable Silicon Rubber
Insulation Core 1: Blue
Core 2: Brown
Wrapping tape PET tape
Drain Wire Solid Tinned Copper wire
Screen Aluminium/Polyester tape
Wrapping tape PET tape
Halogen Free Flame-Retardant (LSZH/HFFR)
Sheath Material
Standard Colour: Red
Standard Put Up Length 305 and 500 metres
*Other Colors, Put Up Lengths and structures can be manufactured upon request, please contact your local B3
International sales representative.
B3 International Page 1 of 2
info@b3cable.com – www.b3cable.com Rev: 1.11
Date: 23/01/2023
Data sheets are subject to change without notice
Fire Resistant Cables - Enhanced
Two core, Overall Screen, LSZH/HFFR Sheath
BS 6387 CWZ, EN 50200 PH120
C1044, C1045, C1283, C1284, C1289, C5126
Physical Characteristics
Reference Standards
EN 50267-2-1, BS EN 50363-1
BS 7655.1.1, BS 7655.6.1 EN 50200 PH120, EN 50200 Annex E
EN 50290-2-27 BS 8434-2+A2:2009 PH120
IEC 60228 IEC 60754-1&-2
IEC 60332-3-24 IEC 61034-1&-2
IEC 60331-21 FE180 BS 6360
BS 6387 CWZ RoHS Directives
*Subject to LPCB certification
B3 International Page 2 of 2
info@b3cable.com – www.b3cable.com Rev: 1.11
Date: 23/01/2023
Data sheets are subject to change without notice
Audio Control & Instrumentation Cable,
2C to 8C, 14AWG Overall Screen,
HFFR/LSZH Sheath
C1701, C1703, C1705, C1707, C1709
Applications
Conductor
Insulation
Al/PET Tape
Sheath
Rip Cord
Drain Wire
Design
Unit Properties
Conductor N x Bare Copper wire, 14AWG flexible
HFFR/LSZH
Core 1: Black
Core 2: White
Core 3: Red
Insulation Core 4: Green
Core 5: Brown
Core 6: Blue
Core 7: Orange
Core 8: Yellow
Drain Wire 24 AWG (7 x 32) Tinned Copper
Screen Aluminium/Polyester 100% Coverage
Rip Cord Nylon Yarn
Flame-Retardant Halogen Free
Sheath Material (HFFR/LSZH)
Standard colour: purple
Standard Put Up Length 305 meters
*Other Colors, Put Up Lengths and structures can be manufactured upon request, please contact your local B3
International sales representative.
B3 International Page 1 of 2
info@b3cable.com – www.b3cable.com Rev: 1.1
Date: 30/05/2015
Datasheets are subject to change without notice
Audio Control & Instrumentation Cable,
2C to 8C, 14AWG Overall Screen,
HFFR/LSZH Sheath
C1701, C1703, C1705, C1707, C1709
Physical Characteristics
Electrical Characteristics
Reference Standards
(BS) EN 50290-2
IEC 60228
IEC 60754-1 & 2
IEC 61034, IEC 60332-3-24
RoHS directives
B3 International Page 2 of 2
info@b3cable.com – www.b3cable.com Rev: 1.1
Date: 30/05/2015
Datasheets are subject to change without notice
5- Country of Origin
6- Product Test
Certificates.
Test Report
C1044-02-0500 2x1.5 sqmm BS 6387 CWZ Screened HFFR
B3 International
info@b3cable.com – www.b3cable.com
Test Report
C1053-06-0305-U/FTP CAT6A HFFR Sheath
Physical Performance
Characteristic Unit Standard Requirement Test Results Remarks
Insulation DCR (20ºC) MΩ*km EN 50290-2-23 > 200 15789 Pass
Insulation Tensile strength, unaged MPa EN 50290-2-23 ≥ 10 15.5 Pass
Insulation Elongation, unaged % EN 50290-2-23 ≥ 300 423.89 Pass
Aging 240 hrs - 100ºC EN 50290-2-23 Pass
Insulation Elongation, aged % EN 50290-2-23 ≥ 300 387.56 Pass
Sheath Tensile strength, unaged MPa EN 50290-2-22-TM51 ≥9 10.91 Pass
Sheath Elongation, unaged % EN 50290-2-22-TM51 ≥ 125 199.45 Pass
Aging 168 hrs - 80ºC EN 50290-2-22-TM51 Pass
Sheath Elongation variation, aged % EN 50290-2-22-TM51 ≤ ± 30 11.2% Pass
Sheath Tensile strength variation, aged % EN 50290-2-22-TM51 ≤ ± 30 5.7% Pass
Heat shock 1 hr at 150°C EN 50290-2-22-TM51 No cracks Pass Pass
Cold bend at -15°C EN 50290-2-22-TM51 No cracks Pass Pass
RoHS Compliant 2002/95/EC Pass Pass
Flame test IEC 60332-1 Pass Pass Pass
Remarks: B3 International hereby declares that above mentioned data was tested towards relevant international standards.
_____________ ___________________
F.Russo Ella Du
Physical Performance
Characteristic Unit Standard Requireme Test Results Remarks
Test Sample Number nt 1 2 3 4 5 6 7
Insulation Tensile strength Mpa (BS) EN 50290-2-27 ≥9 10.04 Pass
Insulation Elongation % (BS) EN 50290-2-27 ≥ 125 247.34 Pass
Insulation Elongation after aging
% (BS) EN 50290-2-27 ≤ ±30 11.8% Pass
168H/100℃
Sheath Tensile strength Mpa (BS) EN 50290-2-27 ≥9 9.74 Pass
Sheath Tensile strength, after aging
% (BS) EN 50290-2-27 ≤ ± 30 6.5% Pass
168H/100℃ Variation
Sheath Elongation % (BS) EN 50290-2-27 ≥ 125 185.74 Pass
Sheath Elongation, after aging
% (BS) EN 50290-2-27 ≤ ±30 11.3% Pass
168H/80℃ Variation
Sheath Heat Shock 1H/150ºC (BS) EN 50290-2-27 no cracks Pass Pass
Sheath Cold Bend 1H/-15 ºC (BS) EN 50290-2-27 no cracks Pass Pass
RoHS Compliance Respective EN directive Pass Pass
Flame Retardancy IEC 60332-3-24 Pass Pass
Low Smoke IEC 61034 Pass Pass
Halogen Free IEC 60754-1&-2 Pass Pass
Remarks: B3 International hereby declares that above mentioned data was tested towards relevant international standards.
_____________ ___________________
F.Russo Ella Du
B3 International S.R.L Tel: +39 02 8732 3325
Via Monti 42 Fax: +39 02 8732 3101
CAP 20016
Milan URL: www.b3cable.com
Italy Email: info@b3cable.com
7- ISO Certificate.
Certificate
Standard ISO 9001:2015
Certificate Registr. No. 01 100 1922565
2022-04-15
TÜV Rheinland Cert GmbH
Am Grauen Stein · 51105 Köln
www.tuv.com
Annex to certificate
Standard ISO 14001:2015
Certificate Registr. No. 01 104 1922565
2022-04-15
TÜV Rheinland Cert GmbH
Am Grauen Stein · 51105 Köln
® TÜV, TUEV and TUV are registered trademarks. Utilisation and application requires prior approval.
Page 1 of 1
www.tuv.com
Certificate
Standard ISO 45001:2018
Certificate Registr. No. 01 213 1922565
2022-04-15
TÜV Rheinland Cert GmbH
Am Grauen Stein · 51105 Köln
www.tuv.com
8- Warranty Letter
Date: 10.03.2016
All our cable are included under five year performance warranty and in
case they fail to meet the performance specification as describes in our
technical data sheets due to manufacturing defect, they will bereplaced
at our expense
Regards,
MATHIAS LUNDH
Director - EU
9- Previous Approvals
Cables Projects
National Guard Housing – Riyadh
Batha Quraish & ICY – 6
Masa’a Haram Extension - Makkah
Escalators & Elevators Project
HADCO Ancillary BLDG
Yanbou Seaport Admin BLDG
Civil Defense – Abha Site
Al-Mashaar Al-Muqadusa – Makkah MMMP
Al Qaser mall - Riyadh
Arac Hotel Makkah
KSU – National Guard Children Hospital
Unified Command center - Makkah
KSU Project ENDT B7 & B8
Umm ul Qura University - Makkah
(PME) Presidency of Metrology & Environment - Jeddah
King Saud Bin Abdul Aziz University Jed & Riyadh
Princess Noora University – Riyadh
CMA Tower – Riyadh
King Abdul Aziz International Airport - Jeddah
MOI – UCC
KSU - Bahra
King Abdullah Financial District – Riyadh (KAFD)
Qurayyah CCPP
ABC – ppl0
Jezan Housing (3000 Villa’s) National Guard
ITCC – Conventional Hotel Riyadh & ICTC
DOKKAH - Makkah
Shamiya Project - Makkah
King Abdulla Foundation Project – Riyadh (KAFP)
Radisson Blu Hotel – Jeddah
Hyatt House Hotel - Jeddah
Rawda Tower - Jeddah
Jebel Omar Development Project - Makkah
Hilton Hotel – Riyadh
SHARMA – North, Tabuk
ROSA Palace - Riyadh
Radisson Blu Hotel – Jeddah
Hyatt House Hotel - Jeddah
Rawda Tower - Jeddah
Jebel Omar Development Project - Makkah
SHARMA Project - Tabuk
Al Raidah Housing - Jeddah
Dhahiat Sumou Development
Thaker City - Makkah
Mental Hospital (400 Bed) - Abha
NEOM Airport – Tabuk
5/21/22, 9:48 AM Aconex
14 Outer Regions
Riyadh, KSA
Riyadh
Saudi Arabia
Status N/A
(0 selected)
Revision
File Document No Revision Title Status
Date
MESSAGE
The attached documents have completed the "14-4800000322/000-IN-Construction - IFR" workflow with the following results :
https://ksa1.aconex.com/Logon 1/2
5/21/22, 9:48 AM Aconex
MOB-ELE-CRS-000194 - Proceed
https://ksa1.aconex.com/Logon 2/2
Material Submittal Form
14-662000-4800000322-
Contractor MOBCO Material Submittal No. MOB-ELE-MAT-000034
Local agent
Delivery Duration
Scheduled Date of
(Long Lead/ Short
Delivery on Site
Lead)
45 Prequalification Approval reference Source Quality Control Reports Certificates & Accreditations
Previous Client Approvals Completed Projects (Similar in Nature) Delegated Design Submittals
Received by Contractor
Signature &
Name
Date
14-662000-4800000322-MOB-ELE-MAT-000034_01 3
Document history
Document approval
14-662000-4800000322-MOB-ELE-MAT-000034_01 4
3/21/22, 10:12 AM Aconex
From Syed Zain Hassan - NEOM - Engineering & Technical Services Dept
Status N/A
(0 selected)
Revision
File Document No Revision Title Status
Date
MESSAGE
The attached documents have completed the "14-4800000322/000-IN-ETSD RQM - IFR(PQP,ITP,PQD,CV)" workflow with the following results
:
14-662000-4800000322-MOB-ELE-MAT-000034_01 7
https://ksa1.aconex.com/Logon 1/2
3/21/22, 10:12 AM Aconex
14-662000-4800000322-
NEOM/AECOM_Review J Maglatang A - Work May Proceed
MOB-ELE-CRS-000125
14-662000-4800000322-MOB-ELE-MAT-000034_01 8
https://ksa1.aconex.com/Logon 2/2
8/22/2021 Aconex
philip green Final (WF-001206) R01H14 - Material Submittal for Fire … 10/04/2021
THE RED SEA DEVELOPMENT COMPANY WORKFLOW TRANSMITTAL TRS01H14-WTRAN-003972
Final (WF-001206) R01H14 - Material Submittal for Fire Alarm Cable And Coaxial
Cable (B3 Brand) for Accommodation and Offices - Supplier "M.AlTaheni Est.
(MTE)"
Status N/A
(1 selected)
R01-H14C03- Accepted
Material Submittal for Fire Alarm Cable And Coaxial Cable (B3 Brand)
BAW-MAT-EL- 00 with
for Accommodation and Offices - Supplier "M.AlTaheni Est. (MTE)"
0010 Comments
ATTRIBUTES
MESSAGE
The attached documents have completed the "R01H14 - Material Submittal for Fire Alarm Cable And Coaxial Cable (B3 Brand) for
Accommodation and Offices - Supplier "M.AlTaheni Est. (MTE)"" workflow with the following results :
https://ksa1.aconex.com/Logon?mainTarget=%2FViewCorrespondence%3FCorrespondence_ID%3D1349348614%26CORRESPONDENCE_MAILBO… 1/2
8/22/2021 Aconex
R01-H14C03-BAW-MAT-
Document Control Review S Alshehri Accepted
EL-0010
a) Italian company B3
approved to supply the
RG6 C1026, RG11 C1027,
and FR C1044&C1045
cables, with the
specifications attached to
the catalog with submitting
a sample for conformity
before supply. b) All
delivered cables
manufactured dates must
be new. c) The approved
cables are subject to be
Supervision Consultant compatible with the
G Sawaya Accepted with Comments
Review SMATV, and Fire Alarm
system by suppliers and
recommendation. d) The
fire-resistant cable color
shall be RED and BLACK
for coaxial as mentioned in
the catalog, e) Warranty
and certificate of origin
shall be submitted. f) The
compliance sheet is not
related to the subject
submittal, the contractor
should follow the guideline
book.
Construction Director
p green Accepted with Comments
Acceptance
https://ksa1.aconex.com/Logon?mainTarget=%2FViewCorrespondence%3FCorrespondence_ID%3D1349348614%26CORRESPONDENCE_MAILBO… 2/2
11/24/21, 7:37 AM Aconex
Status N/A
(0 selected)
MESSAGE
The attached documents have completed the "WS023-EAST- LOW CURRENT CABLES Material Technical Submittals" workflow with the following results :
WS023-RTC-CM-MAR-
Contractor Review R DCC Approved
000073
https://ksa1.aconex.com/Logon 1/1
S5-PRS-01-P01-F12
Material Submittal Form
اد ذج
رو١١٤ ة – ف ذ د وع ا ف ا
Program ح ن ت ور ض اﻷطف ل ا ا درة Package / Group رق
ا – اثن ا/ ا ( ١٠ / ٩ / ٨ /٤ )
يوا ا ق ب١٧ د
Project no. Project name رو ت ا
- ق ١٧ د اق ا جTBC - 01
وع ر ا وع ا ا ي وا ا
Contractor name Material submittal no. ELE – 35
وﻻت لا ء ش
ول ا ا اد ا ر
Contract no. Date
ر ا
TBC-SA-CD-Majal-2342-2020 ا رخ
23/8/2020
CODE B
اﻻﯾطﺎﻟﯾﺔ ﻟﺗورﯾد ﻛﺎﺑل اﻟﺻوﺗﯾﺎت ﺑﺎﻟﻣواﺻﻔﺎت اﻟﻣرﻓﻘﺔ ﺑﺎﻟﻛﺎﺗﻠوج وﺗﻘدﯾم ﻋﯾﻧﺔ ﻟﻠﻣطﺎﺑﻘﺔ ﻗﺑل اﻟﺗورﯾدB3 ﻻ ﻣﺎﻧﻊ ﻣن اﻋﺗﻣﺎد ﺷرﻛﺔ
ﻣﻊ اﻻﻟﺗزام اﻟﺗﺎم ﺑﺎﻟﻣواﺻﻔﺎت اﻟﻔﻧﯾﮫ و ﺟداول اﻟﻛﻣﯾﺎت
ﺳﻌﯾد ﻓﺗﺣﻲ/ م
ﯾﺗم ﺗﻘدﯾم ﻋﯾﻧﺎت ﻟﺟﻣﯾﻊ ﻛﺎﺑﻼت اﻟﺗﯾﺎر اﻟﺧﻔﯾف ﻟﻠﻣطﺎﺑﻘﺔ ﻗﺑل اﻟﺗورﯾد وﻓﻘﺎ ﻟﻠﻣواﺻﻔﺎت اﻟﻔﻧﯾﺔ
Note: ﻼ ظ
These documents have been reviewed for general conformity with Contract terms & conditions, the specifications and bill of
quantities. Such review doesn’t relieve the Contractor of his responsibilities under the terms of the Contract and shall not be
deemed as approval for any further compensation or permission to carry out additional works.
وﻻ ا ا ول ا ا ها وﻻ. ﻷ م وش وط و اص ت و اول ك ت ا ك ه ا ث ئق ا ﺖ
. لإ م ح ت أو أي ا
Package /
Program
ص رو Group G7
ا
ا/ ا
Project no. Project name
TBC-TD-CD-CONS14-5422-2019 ة درة الط ل ال وع
وع ر ا وع ا ا
Material
Contractor name
وﻻت ش وف ل ش submittal no. ECH2-G7-MS-ALL-E-0055
ول ا ا
اد ا ر
Contract no. Date
TBC-SA-CD-SHROOF-2020-340 20-09-2020
ر ا ا رخ
Approved
Subcontractor
Consultant name
دا ب ارا ك (as applicable)
ري اﻻ ا
ول ا ط
()إذا زم ا
Material Description As per
One item only per ﻼت ال ر الخ specification
ن ﻼت الB3
Form (system) ا ﻼت الCAT6A B3 اص با
وصف ا اد ت ﻼت ال Alternative
ذج ﻂ وا ق ﻼت الBulden ا
() ظ م
BOQ reference
Drawing reference no.
ت ا ا ا
ت ول ا
Standards, BS
DIN, ASTM,
Specification reference SASO
اص ا BS ، س ا
DIN, ASTM,
SASO
Address
ال ض ل ج
ان ا Other details
ى أ ص
Local agent
ي د الط ؤ
ا ا ك
Programme date Expected date
material required on of arrival on
site site
اد جا رخا ا رخا
با ا ص لإ
Contractor’s name Date
وﻻت ش وف ل ش 20-09-2020
ول ا ا ا رخ
Signature
ا
Page 1 of 2
Engineer’s comments ﻼحظ ت ال ه س
CODE B
ﻻ ﻣﺎﻧﻊ ﻣن اﻋﺗﻣﺎد ﻛﺎﺑل اﻧذار اﻟﺣرﯾﻖ ﻟﺷرﻛﺔ ﺑﻠدن ﺑﺎﻟﻣواﺻﻔﺎت اﻟﻣرﻓﻘﺔ ﺑﺎﻟﻛﺎﻟﺗﻠوج ﻋﻠﻰ ان ﯾﺗم ﺗﻘدﯾم ﻋﯾﻧﺔ ﻟﻠﻣطﺎﺑﻘﺔ ﻗﺑل اﻟﺗورﯾد ﻣﻊ ﺗﻘدﯾم
ﺷﮭﺎدات اﻟﺿﻣﺎن و اﻟﻣﻧﺷﺄ و اﻟﻣطﺎﺑﻘﺔ ﻋﻠﻰ ان ﯾﻛون اﻟﻛﺎﺑل ﯾﺗﺣﻣل درﺟﺔ ﺣرارة ﺗﺷﻐﯾل 105درﺟﺔ وﻓﻘﺎ ﻟﻠﻛﺎﺗﻠوج اﻟﻣرﻓﻖ
PART NO. 79001FS PART NO. 79002FS ﻣﻊ اﻻﻟﺗزام اﻟﺗﺎم ﺑﺎﻟﻣواﺻﻔﺎت اﻟﻔﻧﯾﺔ وﺟداول اﻟﻛﻣﯾﺎت
ﻻ ﻣﺎﻧﻊ ﻣن اﻋﺗﻣﺎد ﺷرﻛﺔ B3اﻻﯾطﺎﻟﯾﺔ ﻟﺗورﯾد ﻛﺎﺑل اﻟﺻوﺗﯾﺎت وﻛﺎﺑل اﻟداﺗﺎ و ﻛﺎﺑل اﻟﺗﻠﯾﻔون ﺑﺎﻟﻣواﺻﻔﺎت اﻟﻣرﻓﻘﺔ ﺑﺎﻟﻛﺎﺗﻠوج ﻣﻊ ﺗﻘدﯾم ﻋﯾﻧﺔ ﻟﻠﻣطﺎﺑﻘﺔ ﻗﺑل اﻟﺗورﯾد
ﻣﻊ ﺗﻘدﯾم ﺷﮭﺎدات اﻟﺿﻣﺎن و اﻟﻣطﺎﺑﻘﺔ و اﻟﻣﻧﺷﺄ ﻗﺑل اﻟﺗورﯾد ﻣﻊ اﻟﻌﯾﻧﺎت ﻟﻠﻣراﺟﻌﮫ واﻟﻣطﺎﺑﻘﺔ
م /ﺳﻌﯾد ﻓﺗﺣﻲ ﻣﻊ اﻻﻟﺗزام اﻟﺗﺎم ﺑﺎﻟﻣواﺻﻔﺎت اﻟﻔﻧﯾﮫ و ﺟداول اﻟﻛﻣﯾﺎت FOR DATA PART NO. C1200 AND AUDIO CABLE PART NO. C1701
FOR TEL. PART NO. C1031
Note: ﻼ ظ
These documents have been reviewed for general conformity with Contract terms & conditions, the specifications and bill of
quantities. Such review doesn’t relieve the Contractor of his responsibilities under the terms of the Contract and shall not be
deemed as approval for any further compensation or permission to carry out additional works.
وﻻ ا ا ول ا ا ها .وﻻ م وش وط و اص ت و اول ك ت ا ﻷ ه ا ث ئق ك ا ﺖ
. لإ م ح ت أو أي ا
Page 2 of 2
S5-PRS-01-P01-F12
Material Submittal Form
اد ذج
رو١١٤ ة – ف ذ د وع ا ف ا
Program ح ن ت ور ض اﻷطف ل ا ا درة Package / Group رق
ا – اثن ا/ ا ( ١٠ / ٩ / ٨ /٤ )
يوا ا ق ب١٧ د
Project no. Project name رو ت ا
- ق ١٧ د اق ا جTBC - 01
وع ر ا وع ا ا ي وا ا
Contractor name Material submittal no. ELE – 35
وﻻت لا ء ش
ول ا ا اد ا ر
Contract no. Date
ر ا
TBC-SA-CD-Majal-2342-2020 ا رخ
23/8/2020
M.ATTAHEN| EST. / 83
E-y JSi? l. l& $! I etit' bjj stLliid t, LE LUil I ijil." e.\nJ t jL,.1euJ t' g - -.i
Contractor warrant that the submission is fully committed to the drawings and specifications of the
contrac[, except as llterrtiorred later
4 HARD COPIES + 4 CD + SAMPLE
912/2020 f: Date
Approval of materials does not relieve the Contractor of its contractual obligations al8url 4jl-Uill eF &tn!l ua+ ) rl3Jl rLcat
f -i5taa;!i 1+'
l. Consuitant Stamp' NotSpecify or.!L)l!rj)u u rQ[--
"*iil---l
lncorporate Comments & Resubmit
"eey J- I
Rejected o
.'i
N.Amoguis
26-01-2020
Project: Shamiya Extension Project MAKKAH Central Utility
Complex (CUC)
List of reviewed documents:
Submittal Ref. Title Revision
CUC-MAT-BV-EL-G-276 Control Cables For the CBS System 01
(Emergency Lighting Central Battery
System)
Page 1 of 1
10- Legal Documents
رﻣﺰك اﻟﺘﺠﺎري QR Code
ﻣﻦ ﺧﻼﻟﻪ ﻳﻤﻜﻨﻚ اﻟﺘﺤﻘﻖ اﻟﻤﺒﺎﺷﺮ ﻣﻦ اﻟﻌﻠﻮﻣﺎت:
MCgovSA
www.mc.gov.sa
̀˹˺˼˾̀˼˿˾̂
˽˹˼˹˼˽˹˹́˽
˰ϫ˺˽˼˿˹̀˻˼
ΓέΎΟΗϠϟϩΎϛέηϭϲϧϳΣρϟΩϭϣΣϣΔϛέη
ϯΩϭό˰˰˰˰γ ΔρϠΗΧϣΓΩϭΩΣϣΔϳϟϭγϣΕΫ
˰ϫ˺˾˽˾˹̀˼˹ ˰ϫ˺˽˽˼˹̀˺˿ Δϧγ̂̂
˿˾˼˽˻˼˽˼˿ΓΩΟ˼˾˽́
˿˾˼˽˺ ˻˼˽˼˿ ˾˹˿˿˿˾˻˺˻
ϱέΎΟΗϟίϣέϟγϣ˯ΎΟέϟΔρηϧϷΕΎϧΎϳΑϰϠϋωϼρϼϟ
ϱΩϭόγ்˺က˹˹˹က˹˹˹
ϲΑέϐϣϟϥΎοϣέΩϣΣϣϝϼΑ
ΔϛέηϟΩϘϋϪϳϠϋιϧΎϣΏγΣ
ΓΩΟ ΓΩΟ
˰ϫ˺˽˽˽˹˾˹̀ ˻˼́˼˾˿˻˺ ˰ϫ˺˽˽˾˹̀˺˿
àèơƮƨǜǛùơǘƷƽúǩǢǫƱLJǛÞæǧǟƱǞƥǘƷƽ
đĊċčďđčĐďē
ĎĊčĊčĎĊĊĒĎ
ċēđĐĊďĒ
ČċĊČĊĊċĎčČĐ
čĊĊċĊČčČēđ
ďēččēďĐĒď
ČċđĊĒē
ƥǁƳèǠǞƷƫǘÚƵƭǧǪ
100221064831152
ﺗﺸﻬﺪ اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺄن اﻟﻤﻜﻠﻒ أدﻧﺎه ﻣﺴﺠﻞ ﻓﻲ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ
ﺑﺘﺎرﻳﺦ 2022/06/28
Hereby, The General Authority of Zakat & Tax (GAZT) certifies that the taxpayer below is
VAT registered on 28/06/2022
ﻛﻤﻜﻠﻒ ﻣﺴﺠﻞ ﻓﻲ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ،ﻻ ﻳﺠﻮز ﻟﻚ ﺗﺤﺼﻴﻞ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ﻣﻦ ﻋﻤﻼﺋﻚ ﻗﺒﻞ ﺗﺎرﻳﺦ
ﻧﻔﺎذ اﻟﺘﺴﺠﻴﻞ ﺑﺎﻟﻀﺮﻳﺒﺔ .ﻓﻲ ﺣﺎل ﺗﺒﻴﻦ ﻏﻴﺮ ذﻟﻚ ،ﺳﺘﻘﻮم اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺘﻨﻔﻴﺬ اﻟﻐﺮاﻣﺎت اﻟﻤﺴﺘﺤﻘﺔ
100221064831152
First Filing due date: 2022/10/31 ﺗﺎرﻳﺦ اﺳﺘﺤﻘﺎق أول إﻗﺮار ﺿﺮﻳﺒﻲ:
ﻛﻤﻜﻠﻒ ﻣﺴﺠﻞ ﻓﻲ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ،ﻻ ﻳﺠﻮز ﻟﻚ ﺗﺤﺼﻴﻞ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ﻣﻦ ﻋﻤﻼﺋﻚ ﻗﺒﻞ ﺗﺎرﻳﺦ
ﻧﻔﺎذ اﻟﺘﺴﺠﻴﻞ ﺑﺎﻟﻀﺮﻳﺒﺔ .ﻓﻲ ﺣﺎل ﺗﺒﻴﻦ ﻏﻴﺮ ذﻟﻚ ،ﺳﺘﻘﻮم اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺘﻨﻔﻴﺬ اﻟﻐﺮاﻣﺎت اﻟﻤﺴﺘﺤﻘﺔ
١٤٤٥/٠٥/١٣ ﺍﻟﺘﺎﺭﻳﺦ
٢٧/١١/٢٠٢٣ ﺍﻟﻤﻮﺍﻓﻖ
ﺭﻣﺰ ﺍﻟﺸﻬﺎﺩﺓ ٥٩١٣٥١١٣
ﺷﻬﺎﺩﺓ
ﺟﺪﺓ
ﺍﻟﺴﻌﻮﺩﻳﺔ
٥٩٣٣٩٥٦٨٥ ﺭﻗﻢ ﺍﻹﺷﺘﺮﺍﻙ :
ﻣﺼﺪﺭﻩ : ﺭﻗﻢ ﺍﻟﺴﺠﻞ ﺍﻟﺘﺠﺎﺭﻱ٤٠٣٠٣٤٠٠٨٤ :
ﻛﺘﺎﺑﺔ ﺭﻗﻤﺎ
ﺗﺴﻌﺔ ﻭ ﻋﺸﺮﻭﻥ ﻣﺸﺘﺮﻛﺎ ٢٩ ﻋﺪﺩ ﺍﻟﻤﺸﺘﺮﻛﻴﻦ ﺍﻟﺴﻌﻮﺩﻳﻴﻦ
ﺗﺴﻌﺔ ﻭ ﺍﺭﺑﻌﻮﻥ ﻣﺸﺘﺮﻛﺎ ٤٩ ﻋﺪﺩ ﺍﻟﻤﺸﺘﺮﻛﻴﻦ ﻏﻴﺮ ﺍﻟﺴﻌﻮﺩﻳﻴﻦ
ﺛﻤﺎﻧﻴﺔ ﻭ ﺳﺒﻌﻮﻥ ﻣﺸﺘﺮﻛﺎ ٧٨ ﺍﻟﻤﺠﻤﻮﻉ
ﺗﺸﻬﺪ ﺍﻟﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ ﺑﺄﻥ ﺍﻟﻤﻨﺸﺄﺓ ﺍﻟﻤﺬﻛﻮﺭﺓ ﺃﻋﻼﻩ ﻗﺪ ﺃﻭﻓﺖ ﺑﺈﻟﺘﺰﺍﻣﺎﺗﻬﺎ ﺗﺠﺎﻩ ﺍﻟﻤﺆﺳﺴﺔ
ﻭﻓﻖ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻤﻘﺪﻣﺔ ﻣﻨﻬﺎ ﺣﺘﻰ ﺗﺎﺭﻳﺦ ﺇﺻﺪﺍﺭ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ،ﻭﺍﻟﺘﻲ ﺗﻢ ﻣﻨﺤﻬﺎ ﻟﺘﻘﺪﻳﻤﻬﺎ ﻷﻳﺔ ﺟﻬﺔ ﺗﻄﻠﺒﻬﺎ ،ﻭﻫﻲ
ﺻﺎﻟﺤﺔ ﻟﺠﻤﻴﻊ ﺍﻷﻏﺮﺍﺽ ﺍﻟﺘﻲ ﻧﺺ ﻋﻠﻴﻬﺎ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ ﻓﻲ ﺍﻟﻤﺎﺩﺓ ) (١٩/٦ﻣﻨﻪ.
ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﺳﺎﺭﻳﺔ ﺍﻟﻤﻔﻌﻮﻝ ﺣﺘﻰ ١٤٤٥/٠٦/١٣ﻫـ.
ﻋﻦ ﻃﺮﻳﻖ ﺍﺳﺘﺨﺪﺍﻡ ﺃﻭ ﻳﻠﺰﻡ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺻﺤﺔ ﻭﺻﻼﺣﻴﺔ ﺍﻟﺸﻬﺎﺩﺓ ﻋﺒﺮ ﺯﻳﺎﺭﺓ ﺍﻟﺮﺍﺑﻂ
ﺍﻟﺮﻣﺰ ﺍﻟﻤﻌﺮﻑ ﺍﻟﺘﺎﻟﻲ : ﺃﺩﻧﺎﻩ ﻓﻲ ﺍﻟﻤﻮﻗﻊ ﺍﻹﻟﻜﺘﺮﻭﻧﻲ ﻟﻠﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ
www.gosi.gov.sa/vc
ﺗﻌﺪ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﻣﻦ ﺍﻟﻮﺛﺎﺋﻖ ﺍﻻﻟﻜﺘﺮﻭﻧﻴﺔ ﺍﻟﺤﻜﻮﻣﻴﺔ ﺍﻟﺮﺳﻤﻴﺔ ،ﻭﻳﺤﻈﺮ ﻗﻄﻌﻴﺎ ﺗﻘﻠﻴﺪﻫﺎ ﺃﻭ ﺇﺩﺧﺎﻝ ﺃﻱ ﺗﻌﺪﻳﻼﺕ ﻋﻠﻴﻬﺎ ﺳﻮﺍﺀ ﺑﺎﻹﺿﺎﻓﺔ ﺃﻭ ﺍﻟﺤﺬﻑ
ﺃﻭ ﺍﻟﺘﻐﻴﻴﺮ ﻓﻲ ﺑﻴﺎﻧﺎﺗﻬﺎ ﺃﻭ ﻏﻴﺮ ﺫﻟﻚ ﻣﻦ ﺍﻧﻮﺍﻉ ﺍﻟﺘﻌﺪﻳﻞ ،ﻭﺗﻌﺪ ﺍﻟﺸﻬﺎﺩﺓ ﻻﻏﻴﺔ ﺇﺫﺍ ﺷﺎﺑﻬﺎ ﺷﻲﺀ ﻣﻦ ﺫﻟﻚ ،ﻛﻤﺎ ﺗﻌﺮﺽ ﺻﺎﺣﺒﻬﺎ ﻟﻠﻤﻼﺣﻘﺔ ﺍﻟﻨﻈﺎﻣﻴﺔ
ﺃﻣﺎﻡ ﺍﻟﺠﻬﺎﺕ ﺍﻟﻤﺨﺘﺼﺔ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﻣﺎﻳﻔﺮﺿﻪ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ﻣﻦ ﻋﻘﻮﺑﺎﺕ ،ﻭﻻﻳﺠﻮﺯ ﺗﺪﺍﻭﻝ ﺍﻟﺸﻬﺎﺩﺓ ﺇﻻ ﻓﻲ ﺍﻷﻏﺮﺍﺽ ﺍﻟﺘﻲ
ﺃﺻﺪﺭﺕ ﻷﺟﻠﻬﺎ ﻭﻓﻘﺎ ﻷﺣﻜﺎﻡ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ،ﻭﺍﻟﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ﻏﻴﺮ ﻣﺴﺆﻭﻟﻪ ﻋﻦ ﺃﻱ ﺁﺛﺎﺭ ﺃﺧﺮﻯ ﻣﺘﺮﺗﺒﺔ
ﻗﺒﻞ ﺍﻟﻐﻴﺮ ﻋﻦ ﺍﻟﺸﻬﺎﺩﺓ ﻭﻏﻴﺮ ﻣﺴﺆﻭﻟﺔ ﻋﻦ ﺃﻱ ﻋﻤﻠﻴﺔ ﺗﺰﻭﻳﺮ ﺃﻭ ﺗﻌﺪﻳﻞ ﺗﺘﻢ ﻋﻠﻰ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻴﻬﺎ .
/ / / / -
— /
%
1030018512
٣١١٣٣١٦٧٧٥
١٠٣٠٠١٨٥١٢
ﻫـ١٤٤٤/٠٩/٢٦
ﺷﻬﺎدة
Certificate
The Zakat,Tax and Customs ﺗﺸﻬﺪ ﻫﻴﺌﺔ اﻟﺰﻛﺎة واﻟﻀﺮﻳﺒﺔ
Entity Unified No./ID No. ٧٠١٣٥٧٣٦٥٩ رﻗﻢ ﻫﻮﻳﺔ/ اﻟﺮﻗﻢ اﻟﻤﻮﺣﺪ ﻟﻠﻤﻨﺸﺄة
Commercial Registration/License/
٤٠٣٠٣٤٠٠٨٤ ﻋﻘﺪ رﻗﻢ/ رﺧﺼﺔ/ ﺳﺠﻞ ﺗﺠﺎري
Contract No
Has submitted his tax return for the period ending on 31/12/2022 AD, and he ، ﻫـ١٤٤٤/٠٦/٠٧ ﻗﺪم إﻗﺮاره ﻋﻦ اﻟﻔﺘﺮة اﻟﻤﻨﺘﻬﻴﺔ ﻓﻲ
was granted the certificate to complete all his transactions including the وﻗﺪ ﻣﻨﺢ ﻫﺬه اﻟﺸﻬﺎدة ﻹﻧﻬﺎء ﺟﻤﻴﻊ ﻣﻌﺎﻣﻼﺗﻪ ﺑﻤﺎ ﻓﻲ ذﻟﻚ ﺻﺮف
payment of the final amount due on the contract. .ﻣﺴﺘﺤﻘﺎﺗﻪ اﻟﻨﻬﺎﺋﻴﺔ ﻋﻦ اﻟﻌﻘﻮد
The Certificate is valid until 21/10/1445 AH corresponding to 30/04/2024 ﻫـ اﻟﻤﻮاﻓﻖ١٤٤٥/١٠/٢١ ﻳﺴﺮي ﻣﻔﻌﻮل ﻫﺬه اﻟﺸﻬﺎدة ﺣﺘﻰ ﺗﺎرﻳﺦ
AD م٢٠٢٤/٠٤/٣٠
( The Twenty first of Shawwal one thousand four hundred forty-five Hijri ) ( ) اﻟﺤﺎدي و اﻟﻌﺸﺮون ﻣﻦ ﺷﻮال أﻟﻒ و أرﺑﻌﻤﺎﺋﺔ و ﺧﻤﺴﺔ و أرﺑﻌﻮن ﻫﺠﺮي
This certificate is not valid until verified by the Authority's Website: www.zatca.gov.sa
1030018512
٣١١٣٣١٦٧٧٥
١٠٣٠٠١٨٥١٢
١٤٤٤/٠٩/٢٦ﻫـ
اﺧﺮى
ﻓﺮع ﺷﺮﻛﺔ ﻣﺤﻤﻮد اﻟﻄﺤﻴﻨﻲ وﺷﺮﻛﺎة ﻟﻠﺘﺠﺎرة ١٠١٠٨٣٤٩٨١
Riyadh