Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

specs

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

WWW.CONTROLTECHNIQUES.

COM

GENERAL
PURPOSE
DRIVES
COMMANDER C200 | C300

48
WWW.CONTROLTECHNIQUES.COM

COMMANDER C
SIMPLE, RELIABLE
MOTOR CONTROL
0.25kW - 132kW (0.33 hp to 200hp) 100V | 200V | 400V | 575V | 690V

The new Commander C series has been designed to be a simple and reliable AC motor
speed controller that meets advanced requirements in a wide range of applications and
provides optimum user experience.

Applications:

Pumping, Ventilating
& Compressing

Conveying

Lifting, Hoisting
& Winching
Free 5 year warranty
The Commander C series has a highly robust
Access Control design to cope with harsh environments. It has
proven exceptionally reliable and we feel so
assured about this that we have given it a free
5 year warranty.
Processing
(Mixers, Crushers, Agitators, Now you can buy with the same confidence.
Centrifuges, Extruders)
Warranty terms and conditions apply.

49
WWW.CONTROLTECHNIQUES.COM

KEY GENERAL PURPOSE FUNCTIONS


Function Function

Jog Supply loss detection

Bi-polar reference Low DC link operation

Pre-set speeds 8 Analogue input control

Preset timer Analogue output control

Skip frequencies 3 Temperature monitoring

Skip frequency dead bans Digital input control

Local/Remote Digital output control

S-Ramp Relay control

Acceleration Rates Mechanical Brake Controller

Deceleration Rates 8 Keypad button assignment

Pulse train frequency reference 0 - 100kHz Motorised pot

Torque reference Logic function control

Control mode: Linear V/f Timer function control

Control mode: Quadratic V/f Limit switch control

Control mode: Dynamic V/f Variable selector

Control mode: Set Point V/f PID Control

Stator resistance compensation Energy meter

Slip compensation Trip time stamping

Auto-tune static Trip logging 8

Auto-tune rotating Run time log

Catch a spinning motor Control word control

Stop mode: Ramp Auto reset

Stop mode: Coast Cloning

Stop mode: Fast Ramp On-board PLC 30kb

DC injection braking Additional Application parameters 64

Programmable braking Second motor set-up

Motor Pre-heat control Speed feedback via options

50
WWW.CONTROLTECHNIQUES.COM

SPECIFICATION
Environment

Ambient Operating Size 1 - 4: -20°C to 40°C (-4°F to 104°F) @ 3 kHz switching freq. | Operation to 60°C (140°F) with de-rating
Temperature Size 5 - 9: -20°C to 40°C (-4°F to 104°F) @ 3 kHz switching freq. | Operation to 55°C (131°F) with de-rating

Cooling method Forced convection

Humidity 95 % non-condensing at 40 °C (104 °F)

Size 1 - 4: -40°C to 60°C (-40°F to 140°F) — 24 months Max.


Storage Temperature
Size 5 - 9: -40°C to 55°C (-40°F to 131°F) — 24 months Max.

Altitude De-rate the continuous output current by 1% for every 100 m (328 ft) above 1000 m (3,280 ft) to a maximum of 3000 m (9,840 ft)

Vibration Tested in accordance with IEC 60068-2-64 and IEC 60068-2-6

Mechanical Shock Tested in accordance with IEC 60068-2-27 and IEC 60068-2-29

Enclosure Rating IP20, NEMA 1 conduit kits available

IEC/ EN 61800-3 Immunity and Emissions


EN 61000-6-2: Immunity for industrial environments
Electromagnetic Capability EN 61000-6-4: Emissions for industrial environments
EN 61000-3-2: Harmonic current emissions
An EMC data sheet is available on request

RoHS Complies with the Restriction of Hazardous Substances Directive (2011/65/EU)

AC Supply Requirements

100 V models: 100 to 120 Vac ±10% 575 V models: 500 to 575 V+/-10%
Voltage 200 V models: 200 to 240 Vac ±10% 690 V models: 500 to 690 V=/-10%
400 V models: 380 to 480 Vac ±10%

Phases 1Ø and 3Ø (Model dependent)

Maximum Supply Imbalance 2% negative phase sequence, 3% voltage imbalance between phases

Input Frequency 45 to 66 Hz

Input Displacement Power Factor 0.97

Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8 12 & 16 kHz


Switching Frequency
Size 5 - 9: 2, 3, 4, 6, 8 12 & 16 kHz

Output Frequency Range 0 to 550 Hz

Frequency Accuracy ±0.02% of full scale

Frequency Resolution 0.01 Hz

Analog Input Resolution Voltage mode: 11 bits (unipolar) Current mode: 11 bits

Braking Dynamic braking transistor included, requires external resistor

51
WWW.CONTROLTECHNIQUES.COM

Protection

100 V models: 175 Vdc 400 V models: 330 Vdc 690 V models: 435 Vdc
DC Bus Undervoltage Trip
200 V models: 175 Vdc 575 V models: 435 Vdc

Frame sizes 1 - 4:
100 V models: 510 Vdc 200 V models: 510 Vdc 400V models: 870 Vdc

DC Bus Overvoltage Trip Frame size 5 - 9:


200V models: 415 Vdc 575 V models: 990 Vdc
400 V models: 830 Vdc 690 V models: 1190 Vdc

Drive Overload Trip Programmable: Default settings: 180% for 3s, 150% for 60s

Instantaneous Overcurrent Trip 220% of rated motor current

Phase Loss Trip DC bus ripple threshold exceeded

Over-temperature Trip Drive heatsink temperature exceeds 95°C (203°F)

Short Circuit Trip Protects against output phase-to-phase fault

Ground Fault Trip Protects against output phase-to-ground fault

Motor Thermal Trip Electronically protects the motor from overheating due to loading conditions

Approval & Listings

UL, cUL UL file NMMS/8: E171230

CE CE approval

These products comply with the Restriction of Hazardous Substances Directive (2011/65/EU), the Low Voltage Directive (2014/35/
EU
EU) and the Electromagnetic Compatibility Directive, (2014/30/EU).

RCM RCM Registered supplier No. 12003815281

ISO Manufacturing facilities comply with ISO 9001:2015 and ISO 14001

C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a machine.
Type examination certificates by TÜV Rheinland:
Frame sizes 1 - 4: No. 01/205/5383.03/18
Frame sizes 5 - 9: No. 01/205/5387.02/18
TÜV
Functional safety parameters:
EN ISO 13849-1 - Cat 4, PLe
EN61800-5-2/EN62061/IEC 61508 - SIL 3
UL functional safety approval: FSPC E171230

EAC RU C-GB.HA10.B.01062

Documentation & Downloads


Product documentation and PC tools available for download from:
www.controltechniques.com/support

52
WWW.CONTROLTECHNIQUES.COM

DIMENSIONS
Mounting W
Overall Dimensions Mounting Dimensions Weight
Hole Diameter

Frame Size mm in mm in
mm in kg lb
H W D H W D H W H W

1 160 75 130 6.3 2.95 5.1 143 53 5.7 2.08 5 0.2 0.75 1.65 H

2 205 75 150 8.07 2.95 5.9 194 55 7.63 2.17 5 0.2 1.3 3

3 226 90 160 8.9 3.54 6.3 215 70.7 8.46 2.8 5 0.2 1.5 3.3

4 277 115 175 10.9 4.5 6.9 265 86 10.43 3.4 6 0.23 3.13 6.9

5 391 143 200 15.39 5.63 7.87 375 106 14.76 4.17 6.5 0.26 7.4 16.3 D

6 291 210 227 15.39 8.27 8.94 378 196 14.88 7.72 7 0.28 14 30.9

7 557 270 280 21.93 10.63 11.02 538 220 21.18 8.66 9 0.35 28 61.7

8 804 310 290 31.65 12.21 11.42 884 259 30.87 10.2 9 0.35 52 114.6

9E 1069 310 290 42.09 12.21 11.42 1051 259 41.38 10.2 9 0.35 46 101.4

9A 1108 310 290 43.62 12.21 11.42 1090 259 42.91 10.2 9 0.35 66.5 146.6

CONNECTIONS

Typical Power Connections Default Control Connections

53
WWW.CONTROLTECHNIQUES.COM

PART NUMBERS
C200 03 4 0073 A 10 1 00 AB 100

Frame Size Heavy Duty Current CT Reserved Product Variant


Rating x 10 AB 100 - Standard

Drive Range Voltage Rating A - Internal Line Choke Default Setting


C200 - The lead product for 1 = 100 V E - External Line Choke Required 00 - CT Default
the Commander range 2 = 200 V 01 - US Default
C300 - As C200 + Dual STO 4 = 400 V
5 = 575 V
6 = 690 V

Note: For the STO variants just replace the C200 digits at the start of the part number with C300.

ORDERING GUIDE
How to select a drive
Electrical Considerations Drive Mechanical Mounting
• What is the supply voltage? • Panel mounting – as standard

• Single or three phase input power? • Wall mounting – UL conduit kits are available
• Through panel mounting – frames 5 and up
• What is the motor rating?

• Continuous current – FLA (Full Load Amps)

• Select the drive based on motor Amps rather than


kilowatt/horsepower rating

54
WWW.CONTROLTECHNIQUES.COM

MODEL NUMBER AND RATINGS


100/200 VAC +/-10%

Heavy Duty Normal Duty


Input
Product Code Size
Phases Max Cont. Current Motor Power Motor Power Max Cont. Current Motor Power Motor Power
(A) (kW) (HP) (A) (kW) (HP)

C200-01100017A10100AB100 01 1 1.7 0.25 0.33

C200-01100024A10100AB100 01 1 2.4 0.25 0.5


For Normal Duty applications,
use Heavy Duty ratings.
C200-02100042A10100AB100 02 1 4.2 0.75 1

C200-02100056A10100AB100 02 1 5.6 1.1 1.5

200/240 VAC +/-10%

Heavy Duty Normal Duty


Input
Product Code Size
Phases Max Cont. Current Motor Power Motor Power Max Cont. Current Motor Power Motor Power
(A) (kW) (HP) (A) (kW) (HP)

C200-01200024A10100AB100 1 1 2.4 0.37 0.5

C200-01200033A10100AB100 1 1 3.3 0.55 0.75

C200-01200042A10100AB100 1 1 4.2 0.75 1

C200-02200024A10100AB100 2 1|3 2.4 0.37 0.5

C200-02200033A10100AB100 2 1|3 3.3 0.55 0.75

For Normal Duty applications,


C200-02200042A10100AB100 2 1|3 4.2 0.75 1
use Heavy Duty ratings.

C200-02200056A10100AB100 2 1|3 5.6 1.1 1.5

C200-02200075A10100AB100 2 1|3 7.5 1.5 2

C200-03200100A10100AB100 3 1|3 10 2.2 3

C200-04200133A10100AB100 4 1|3 13.3 3 3

C200-04200176A10100AB100 4 3 17.6 4 5

C200-05200250A10100AB100 5 3 25 5.5 7.5 30 7.5 10

C200-06200330A10100AB100 6 3 33 7.5 10 50 11 15

C200-06200440A10100AB100 6 3 44 11 15 58 15 20

C200-07200610A10100AB100 7 3 61 15 20 75 18.5 25

C200-07200750A10100AB100 7 3 75 18.5 25 94 22 30

C200-07200830A10100AB100 7 3 83 22 30 117 30 40

55
WWW.CONTROLTECHNIQUES.COM

C200-08201160A10100AB100 8 3 116 30 40 149 37 50

C200-08201320A10100AB100 8 3 132 37 50 180 45 60

C200-09201760A10100AB100 9 3 176 45 60 216 55 75

C200-09202190A10100AB100 9 3 219 55 75 266 75 100

C200-09201760E10100AB100 9 3 176 45 60 216 55 75

C200-09202190E10100AB100 9 3 219 55 75 266 75 100

C200-02200056A10100AB100 2 1|3 5.6 1.1 1.5

C200-02200075A10100AB100 2 1|3 7.5 1.5 2

For Normal Duty applications,


C200-03200100A10100AB100 3 1|3 10 2.2 3
use Heavy Duty ratings.

C200-04200133A10100AB100 4 1|3 13.3 3 3

C200-04200176A10100AB100 4 3 17.6 4 5

C200-05200250A10100AB100 5 3 25 5.5 7.5 30 7.5 10

C200-06200330A10100AB100 6 3 33 7.5 10 50 11 15

C200-06200440A10100AB100 6 3 44 11 15 58 15 20

C200-07200610A10100AB100 7 3 61 15 20 75 18.5 25

C200-07200750A10100AB100 7 3 75 18.5 25 94 22 30

C200-07200830A10100AB100 7 3 83 22 30 117 30 40

C200-08201160A10100AB100 8 3 116 30 40 149 37 50

C200-08201320A10100AB100 8 3 132 37 50 180 45 60

C200-09201760A10100AB100 9 3 176 45 60 216 55 75

C200-09202190A10100AB100 9 3 219 55 75 266 75 100

C200-09201760E10100AB100 9 3 176 45 60 216 55 75

C200-09202190E10100AB100 9 3 219 55 75 266 75 100

56
WWW.CONTROLTECHNIQUES.COM

380/480 VAC +/-10%

Heavy Duty Normal Duty


Input
Product Code Size
Phases Max Cont. Current Motor Power Motor Power Max Cont. Current Motor Power Motor Power
(A) (kW) (HP) (A) (kW) (HP)

C200-02400018A10100AB100 2 3 1.8 0.55 0.75

C200-02400023A10100AB100 2 3 2.3 0.75 1

C200-02400032A10100AB100 2 3 3.2 1.1 1.5

C200-02400041A10100AB100 2 3 4.1 1.5 2

For Normal Duty applications,


C200-03400056A10100AB100 3 3 5.6 2.2 3
use Heavy Duty ratings.

C200-03400073A10100AB100 3 3 7.3 3 3

C200-03400094A10100AB100 3 3 9.4 4 5

C200-04400135A10100AB100 4 3 13.5 5.5 7.5

C200-04400170A10100AB100 4 3 17 7.5 10

C200-05400270A10100AB100 5 3 27 11 20 30 15 20

C200-05400300A10100AB100 5 3 30 15 20 30 15 20

C200-06400350A10100AB100 6 3 35 15 25 38 18.5 25

C200-06400420A10100AB100 6 3 42 18.5 30 48 22 30

C200-06400470A10100AB100 6 3 47 22 30 63 30 40

C200-07400660A10100AB100 7 3 66 30 50 79 37 50

C200-07400770A10100AB100 7 3 77 37 60 94 45 60

C200-07401000A10100AB100 7 3 100 45 75 112 55 75

C200-08401340A10100AB100 8 3 134 55 100 155 75 100

C200-08401570A10100AB100 8 3 157 75 125 184 90 125

C200-09402000A10100AB100 9 3 200 90 150 221 110 150

C200-09402240A10100AB100 9 3 224 110 150 266 132 200

C200-09402000E10100AB100 9 3 200 90 150 221 110 150

C200-09402240E10100AB100 9 3 224 110 150 266 132 200

57
WWW.CONTROLTECHNIQUES.COM

500/575 VAC +/-10%

Heavy Duty Normal Duty


Input
Product Code Size
Phases Max Cont. Current Motor Power Motor Power Max Cont. Current Motor Power Motor Power
(A) (kW) (HP) (A) (kW) (HP)

C200-05500040A10100AB100 5 3 4 2.2 3 6.1 4 5

C200-05500069A10100AB100 5 3 6.9 4 5 10 5.5 7.5

C200-06500100A10100AB100 6 3 10 5.5 7.5 12 7.5 10

C200-06500150A10100AB100 6 3 15 7.5 10 17 11 15

C200-06500190A10100AB100 6 3 19 11 15 22 15 20

C200-06500230A10100AB100 6 3 23 15 20 27 18.5 25

C200-06500290A10100AB100 6 3 29 18.5 25 34 22 30

C200-06500350A10100AB100 6 3 35 22 30 43 30 40

C200-07500440A10100AB100 7 3 44 30 40 53 37 50

C200-07500550A10100AB100 7 3 55 37 50 73 45 60

C200-08500630A10100AB100 8 3 63 45 60 86 55 75

C200-08500860A10100AB100 8 3 86 55 75 108 75 100

C200-09501040A10100AB100 9 3 104 75 100 125 90 125

C200-09501310A10100AB100 9 3 131 90 125 150 110 150

C200-09501040E10100AB100 9 3 104 75 100 125 90 125

C200-09501310E10100AB100 9 3 131 90 125 150 110 150

500/690 VAC +/-10%

Heavy Duty Normal Duty


Input
Product Code Size
Phases Max Cont. Current Motor Power Motor Power Max Cont. Current Motor Power Motor Power
(A) (kW) (HP) (A) (kW) (HP)

C200-07600240A10100AB100 7 3 24 18.5 25 30 22 30

C200-07600290A10100AB100 7 3 29 22 30 36 30 40

C200-07600380A10100AB100 7 3 38 30 40 46 37 50

C200-07600440A10100AB100 7 3 44 37 50 52 45 60

C200-07600540A10100AB100 7 3 54 45 60 73 55 75

C200-08600630A10100AB100 8 3 63 55 75 86 75 100

C200-08600860A10100AB100 8 3 86 75 100 108 90 125

C200-09601040A10100AB100 9 3 104 90 125 125 110 150

C200-09601310A10100AB100 9 3 131 110 150 150 132 175

C200-09601040E10100AB100 9 3 104 90 125 125 110 150

C200-09601310E10100AB100 9 3 131 110 150 150 132 175

58