specs
specs
specs
COM
GENERAL
PURPOSE
DRIVES
COMMANDER C200 | C300
48
WWW.CONTROLTECHNIQUES.COM
COMMANDER C
SIMPLE, RELIABLE
MOTOR CONTROL
0.25kW - 132kW (0.33 hp to 200hp) 100V | 200V | 400V | 575V | 690V
The new Commander C series has been designed to be a simple and reliable AC motor
speed controller that meets advanced requirements in a wide range of applications and
provides optimum user experience.
Applications:
Pumping, Ventilating
& Compressing
Conveying
Lifting, Hoisting
& Winching
Free 5 year warranty
The Commander C series has a highly robust
Access Control design to cope with harsh environments. It has
proven exceptionally reliable and we feel so
assured about this that we have given it a free
5 year warranty.
Processing
(Mixers, Crushers, Agitators, Now you can buy with the same confidence.
Centrifuges, Extruders)
Warranty terms and conditions apply.
49
WWW.CONTROLTECHNIQUES.COM
50
WWW.CONTROLTECHNIQUES.COM
SPECIFICATION
Environment
Ambient Operating Size 1 - 4: -20°C to 40°C (-4°F to 104°F) @ 3 kHz switching freq. | Operation to 60°C (140°F) with de-rating
Temperature Size 5 - 9: -20°C to 40°C (-4°F to 104°F) @ 3 kHz switching freq. | Operation to 55°C (131°F) with de-rating
Altitude De-rate the continuous output current by 1% for every 100 m (328 ft) above 1000 m (3,280 ft) to a maximum of 3000 m (9,840 ft)
Mechanical Shock Tested in accordance with IEC 60068-2-27 and IEC 60068-2-29
AC Supply Requirements
100 V models: 100 to 120 Vac ±10% 575 V models: 500 to 575 V+/-10%
Voltage 200 V models: 200 to 240 Vac ±10% 690 V models: 500 to 690 V=/-10%
400 V models: 380 to 480 Vac ±10%
Maximum Supply Imbalance 2% negative phase sequence, 3% voltage imbalance between phases
Input Frequency 45 to 66 Hz
Analog Input Resolution Voltage mode: 11 bits (unipolar) Current mode: 11 bits
51
WWW.CONTROLTECHNIQUES.COM
Protection
100 V models: 175 Vdc 400 V models: 330 Vdc 690 V models: 435 Vdc
DC Bus Undervoltage Trip
200 V models: 175 Vdc 575 V models: 435 Vdc
Frame sizes 1 - 4:
100 V models: 510 Vdc 200 V models: 510 Vdc 400V models: 870 Vdc
Drive Overload Trip Programmable: Default settings: 180% for 3s, 150% for 60s
Motor Thermal Trip Electronically protects the motor from overheating due to loading conditions
CE CE approval
These products comply with the Restriction of Hazardous Substances Directive (2011/65/EU), the Low Voltage Directive (2014/35/
EU
EU) and the Electromagnetic Compatibility Directive, (2014/30/EU).
ISO Manufacturing facilities comply with ISO 9001:2015 and ISO 14001
C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a machine.
Type examination certificates by TÜV Rheinland:
Frame sizes 1 - 4: No. 01/205/5383.03/18
Frame sizes 5 - 9: No. 01/205/5387.02/18
TÜV
Functional safety parameters:
EN ISO 13849-1 - Cat 4, PLe
EN61800-5-2/EN62061/IEC 61508 - SIL 3
UL functional safety approval: FSPC E171230
EAC RU C-GB.HA10.B.01062
52
WWW.CONTROLTECHNIQUES.COM
DIMENSIONS
Mounting W
Overall Dimensions Mounting Dimensions Weight
Hole Diameter
Frame Size mm in mm in
mm in kg lb
H W D H W D H W H W
1 160 75 130 6.3 2.95 5.1 143 53 5.7 2.08 5 0.2 0.75 1.65 H
2 205 75 150 8.07 2.95 5.9 194 55 7.63 2.17 5 0.2 1.3 3
3 226 90 160 8.9 3.54 6.3 215 70.7 8.46 2.8 5 0.2 1.5 3.3
4 277 115 175 10.9 4.5 6.9 265 86 10.43 3.4 6 0.23 3.13 6.9
5 391 143 200 15.39 5.63 7.87 375 106 14.76 4.17 6.5 0.26 7.4 16.3 D
6 291 210 227 15.39 8.27 8.94 378 196 14.88 7.72 7 0.28 14 30.9
7 557 270 280 21.93 10.63 11.02 538 220 21.18 8.66 9 0.35 28 61.7
8 804 310 290 31.65 12.21 11.42 884 259 30.87 10.2 9 0.35 52 114.6
9E 1069 310 290 42.09 12.21 11.42 1051 259 41.38 10.2 9 0.35 46 101.4
9A 1108 310 290 43.62 12.21 11.42 1090 259 42.91 10.2 9 0.35 66.5 146.6
CONNECTIONS
53
WWW.CONTROLTECHNIQUES.COM
PART NUMBERS
C200 03 4 0073 A 10 1 00 AB 100
Note: For the STO variants just replace the C200 digits at the start of the part number with C300.
ORDERING GUIDE
How to select a drive
Electrical Considerations Drive Mechanical Mounting
• What is the supply voltage? • Panel mounting – as standard
• Single or three phase input power? • Wall mounting – UL conduit kits are available
• Through panel mounting – frames 5 and up
• What is the motor rating?
54
WWW.CONTROLTECHNIQUES.COM
C200-04200176A10100AB100 4 3 17.6 4 5
C200-06200330A10100AB100 6 3 33 7.5 10 50 11 15
C200-06200440A10100AB100 6 3 44 11 15 58 15 20
C200-07200610A10100AB100 7 3 61 15 20 75 18.5 25
C200-07200750A10100AB100 7 3 75 18.5 25 94 22 30
C200-07200830A10100AB100 7 3 83 22 30 117 30 40
55
WWW.CONTROLTECHNIQUES.COM
C200-04200176A10100AB100 4 3 17.6 4 5
C200-06200330A10100AB100 6 3 33 7.5 10 50 11 15
C200-06200440A10100AB100 6 3 44 11 15 58 15 20
C200-07200610A10100AB100 7 3 61 15 20 75 18.5 25
C200-07200750A10100AB100 7 3 75 18.5 25 94 22 30
C200-07200830A10100AB100 7 3 83 22 30 117 30 40
56
WWW.CONTROLTECHNIQUES.COM
C200-03400073A10100AB100 3 3 7.3 3 3
C200-03400094A10100AB100 3 3 9.4 4 5
C200-04400170A10100AB100 4 3 17 7.5 10
C200-05400270A10100AB100 5 3 27 11 20 30 15 20
C200-05400300A10100AB100 5 3 30 15 20 30 15 20
C200-06400350A10100AB100 6 3 35 15 25 38 18.5 25
C200-06400420A10100AB100 6 3 42 18.5 30 48 22 30
C200-06400470A10100AB100 6 3 47 22 30 63 30 40
C200-07400660A10100AB100 7 3 66 30 50 79 37 50
C200-07400770A10100AB100 7 3 77 37 60 94 45 60
57
WWW.CONTROLTECHNIQUES.COM
C200-06500150A10100AB100 6 3 15 7.5 10 17 11 15
C200-06500190A10100AB100 6 3 19 11 15 22 15 20
C200-06500230A10100AB100 6 3 23 15 20 27 18.5 25
C200-06500290A10100AB100 6 3 29 18.5 25 34 22 30
C200-06500350A10100AB100 6 3 35 22 30 43 30 40
C200-07500440A10100AB100 7 3 44 30 40 53 37 50
C200-07500550A10100AB100 7 3 55 37 50 73 45 60
C200-08500630A10100AB100 8 3 63 45 60 86 55 75
C200-07600240A10100AB100 7 3 24 18.5 25 30 22 30
C200-07600290A10100AB100 7 3 29 22 30 36 30 40
C200-07600380A10100AB100 7 3 38 30 40 46 37 50
C200-07600440A10100AB100 7 3 44 37 50 52 45 60
C200-07600540A10100AB100 7 3 54 45 60 73 55 75
C200-08600630A10100AB100 8 3 63 55 75 86 75 100
58