Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Set up mode for RVP510 Encoder

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Encoder PerformanceLine

RxPxxx menu navigation

706402/00 09/2015 page 1 of 7 © ifm electronic gmbh


Contents

1 Abbreviations ................................................................... 3
2 Encoder to speed monitor .............................................. 4
3 Encoder (Enc)................................................................... 5
4 Speed monitor (rPm) ....................................................... 6
5 Counter mode (Cnt) ......................................................... 7

Safety instructions

 Please read the product description prior to set-up of the unit. Ensure that
the product is suitable for your application without any restrictions.

 The unit complies with the relevant regulations and EC directives.

 Improper or non-intended use may lead to malfunctions of the unit or to


unwanted effects in your application.

 That is why installation, electrical connection, set-up, operation and


maintenance of the unit must be carried out by qualified personnel
authorised by the machine operator.

706402/00 09/2015 page 2 of 7 © ifm electronic gmbh


1 Abbreviations
ENC => Encoder / Drehgeber

rPM => rounds per Minute / Umdrehung pro Minute

Cnt => Counter / Zähler

rslt => Resolution / Auflösung

CDir => Count Direction / Drehrichtung

CW => clock wise / in Uhrzeigerrichtung

CCW => counter clock wise / gegen die Uhrzeigerrichtung


ZEro => Zero / Reset des aktuellen Wertes
PST => Position / Wert für den Schaltpunkt

Ou1 => Output / Schaltausgang

SP1 => Setpoint / Einschaltpunkt

RP1 => Resetpoint / Ausschaltpunkt

FL1 => Window low / Fensterfunktion unterer Einschaltpunkt

FH1 => Window high / Fensterfunktion oberer Ausschaltpunkt

In1 => Input / externer Eingang


h.Tim => high Time / Dauer des Schaltausgangs von Ou1

SDLY => Startup Delay / Schaltverzögerung von Ou1


Mode => Mode / Modus

EF => Extended Function / erweiterte Funktionen

RES => Reset / Werkssreset

COLR => Colour / Displayfarbe

DIS => Display / Aktualisierung des Displays

706402/00 09/2015 page 3 of 7 © ifm electronic gmbh


2 Encoder to speed monitor

Preset: Encoder (ENC)


Change to: Speed monitor (rPm)

Enter
rSLt 1024

CDir cw

out TTL

Cnt
Enter Enter
Mode Enc or Enc rPm Safe
2s Enc

EF coLr

With the setting


Mode Cnt

706402/00 09/2015 page 4 of 7 © ifm electronic gmbh


3 Encoder (Enc)

Preset: 1024 signals and HTL


Change to: 360 signals and TTL

361
Enter Enter Enter
rSLt 1024 or 1024 360 Safe
2s 359

CDir cw

HTL
Enter Enter
out HTL or HTL TTL Safe
2s

Mode Enc

EF coLr

706402/00 09/2015 page 5 of 7 © ifm electronic gmbh


4 Speed monitor (rPm)

Preset: rpm with hysteresis function


Modification to: Hz with window function

rPm
Enter Enter Enter
uni rPm or rPm HZ Safe
2s

SP1 Setup => ou1 = Hno/Hnc*

FH1 83.3

RP1 Setup => ou1 = Hno/Hnc*

FL1 66.7
Hnc
Enter Enter
ou1 Hno or Hno Fno Safe
2s Fnc
SDLY 0.5

Mode rPm

EF coLr

* This menu is only displayed for the hysteresis function (Hno or Hnc).

706402/00 09/2015 page 6 of 7 © ifm electronic gmbh


5 Counter mode (CnT)

Preset: 1024 pulses at PSt 1000 pulses and Ou1 = PSt


Modification to: 360 pulses at PSt 90 pulses and Ou1 = PSt+

361
Enter Enter Enter
rSLt 1024 or 1024 360 Safe
2s 359
CDir cw

ZEro ‐‐‐‐ 91
Enter
Enter or 1000 90 Safe
PSt 1000
2s

Enter Enter
ou1 PSt or PSt PSt+ Safe
2s
PSt‐
In1 PSt

h.Tim 0.0

Mode Enc

EF 0.5

706402/00 09/2015 page 7 of 7 © ifm electronic gmbh