Temperature sensors

E52-E
The E52-E PT100 and thermocouples provide accurate temperature
sensing for standard as well as challenging environments, special ap-
plications and special mounting requirements. The E52-E series is
optimized to work with the range of E5 temperature controllers.
• Thermocouples and PT100 elements
• Wide range of housing, mounting and connection options
• Best performance match with E5 temperature controller portfolio
• Line up for best fitting application performance

Ordering information
Temperature
Type Sensing tube Connection
range
Shape
Diameter

Line Order code


Length

Length
[mm]

[mm]

type*1 Tech- Sub- Min Max

[m]
Series Material Type Fixing
nology type [°C] [°C]

3 E52-ETT3-100-2-A
T 400
6 E52-ETT6-100-2-A
1 E52-ETJ1-100-2-A
–80 2 SUS 316 E52-ETJ2-100-2-A
600 3 E52-ETJ3-100-2-A
4.5 E52-ETJ4.5-100-2-A
J 6 E52-ETJ6-100-2-A
4 E52-ELTJ4-100-2-A
5 E52-ELTJ5-100-2-A
0 400 SUS 304
6 pre-wired E52-ELTJ6-100-2-A
Thermo-
100 2-wire with cable
couple 8 E52-ELTJ8-100-2-A
end shoes
1 E52-ETK1-100-2-A
2 E52-ETK2-100-2-A
smooth tube –80 1100 3 INCONEL 600 E52-ETK3-100-2-A
4.5 E52-ETK4.5-100-2-A
6 2 E52-ETK6-100-2-A
K
4 E52-ELTK4-100-2-A
5 E52-ELTK5-100-2-A
0 400 SUS 304
6 E52-ELTK6-100-2-A
8 E52-ELTK8-100-2-A
3 250 pre-wired E52-EP3-250-2-B
–50 500 SUS 316 with open
6 250 cable ends E52-EP6-250-2-B
4 50 E52-ELP4-50-2-A
PT100 class B 5 3-wire pre-wired E52-ELP5-100-2-A
0 SUS 304 with cable
6 100 end shoes E52-ELP6-100-2-A
400 8 E52-ELP8-100-2-A
–50 6 35 pre-wired E52-EP6-35-2-BG1/4G-B
bajonet
SUS 316 with open
mounting
J 6 15 cable ends E52-ETJ6-15-2-BG1/4G-B
Thermo-
0
couple
enclosed K 1150 6 200 INCONEL 600 2-wire enclosed E52-ETK6-200-T2-B
terminals, screw –
smooth tube PT100 class B –50 500 6 200 SUS 316 terminals E52-EP6-200-T2-B
*1
See Dimensions on page 3

1
E52-E

Temperature
Type Sensing tube Connection
range
Shape

Diameter
Line Order code

Length

Length
[mm]

[mm]
type*1 Tech- Sub- Min Max

[m]
Series Material Type Fixing
nology type [°C] [°C]

enclosed Thermo- K 1150 6 200 INCONEL 600 E52-ETK6-200-T2-CG1/2G-B


terminals, 0 2-wire
couple J 720 6 200 E52-ETJ6-200-T2-CG1/2G-B
G1/2"g
mounting 500 6 200 E52-EP6-200-T2-CG1/2G-B
enclosed
terminals; enclosed
Clamp 6 screw – E52-EP6-100-T2-CC1.5-B
mounting SUS 316 terminals
PT100 class B –50 3-wire
1.5" 200 100
enclosed
terminals;
6 E52-EP6-100-T2-CC2-B
Clamp
mounting 2"
dia
pre-wired
Surface Thermo- 4 mm
J 0 250 10 Cu (tin plated) 2-wire with open 2 E52-ETJS1-B
temperature couple screw
cable ends
hole
Environmen- –40 80 Aluminium enclosed E52-EPE1-B
tal tempera- PT100 class B – – 3-wire screw –
ture –40 80 PVC terminals E52-EPE2-B
up to
Sn = 10 260 M18 44.5 ABS 4-wire 3 ES1B
60 mm pre-wired
Infrared
Non-contact with open
sensor up to cable ends
Sn = 0 400 M18 120 SUS 304 5-wire 2 ES1C-A40
1m
*1
See Dimensions on page 3
Note: Models with tube diameters of 2 inches, 3 inches and 4 inches are available. Refer to the separate E52 Inch Temperature Sensor Datasheet.
Accessories
Temperature range
Type Size Length Material Order code
Min [°C] Max [°C]
RC 1/2 6 E52-EACF1/2-6-B
Compression fitting –200 800 AISI 316
RC 1/4 6 E52-EACF1/4-6-B
1 E52-EACW-K1-B
K
25 E52-EACW-K25-B
Compensation cable Thermocouple –40 200 n.a. Silicone rubber
1 E52-EACW-J1-B
J
25 E52-EACW-J25-B
male E52-EACC-JM1-B
J
Compensation female E52-EACC-JF1-B
–50 120 Thermoplastic
connector male E52-EACC-KM1-B
K
female E52-EACC-KF1-B
10 (for 6) E52-EATW1/2G-10-6-150-B
Thermo well*1 G1/2 gas –200 800 150 AISI 316
12 (for 8) E52-EATW1/2G-12-8-150-B
Signal converters (for Pt100 E52-EASCP1-B
enclosed terminal DIGITAL K E52-EASCK1-B
type) J E52-EASCJ1-B
*1
Thermo wells with different tube lengths and diameters are available. For solutions with matching pairs of temperature sensors and thermowells with fitting screw
connections, contact your Omron representative.

Options (available on request)


1) Sensing head variations 3) Connection variations
a) tip shapes a) pre-wired length please specify length
b) lengths please specify required length material (fiberglass, silicone, teflon, PVC)
c) diameters please specify required diameter (metric or inch) colour codings (refer to page 5)
ends (open, cable shoes, cable clamps)
2) Mounting variations b) Terminals open
a) termowell (different process side thread and well fittings) enclosed
b) bajonet (different process side thread and bajonet fittings)
c) thread (different sizes and types (metric, inch) 4) Special types
Please contact your OMRON representative for special applications
e.g. surface temperature measurement, for hygienic environments,
special shapes, mountings, materials, etc.

2
E52-E
Dimensions
(Detailed dimension drawings are available for each model on request)
Smooth tube types (thermocouples T, J and K and PT100)
E52-ET_ E52-ELT_ E52-EP_ E52-ELP_
dia. dia. dia.

tube length
tube length tube length

250

Ø6 40

connection length connection length


connection length
2000

Bayonet mounting types (PT100) Compensation connector 1 types


E52-EP6-_-2-B_-_ (thermocouples J and K)
E52-ETJ_-_-C1-_/E52-ETK_-_-C1-_

tube
180 max. length
2000 tube length

Note: compatible with female connectors E52-EACC-JF1-_ / E52-EACC-KF1-_


Enclosed terminal types (thermocouples J and K and PT100)
E52-E_-_-T2-_-_
Smooth tube G½˝ mounting Clamp mounting

15

200 130
200
100

3
E52-E

Surface temperature measurement types Environment temperature measurement types


E52-ETJS1-B E52-ESTPCPAN_ E52-EPE1-B E52-EPE2-B
62 62

30

80 80

2000

5000

62 62

20 20

Non-contact – Infrared sensor types


ES1B

44.5 3,000 Mounting Lock Nuts (Two) (Provided)


6.5 ABS resin
Polyolefin tube
Green, Output +
White, Output –
17.8 14.2 dia. 24
Orange, Power +
Shield, Power –
PVC-covered
15 36.5 Screw M18×1.0 (–25°C to 70°C) 26 7

ES1C
12 dia. (lens diameter)

M18×P1.0

60 (threaded section)

24 120 2,000
(cable length)

Accessories
Compression fittings
E52-EACF1/2_ E52-EACF1/4_

~31 ~25

Thermowells Compensation connectors


E52-EATW_ E52-EACC-_M_-_ E52-EACC-_F_-_

10 15 150
175

4
E52-E
Colour codings of compensation cables
(unless otherwise specified the colour coding for sensors is according to IEC 584-3)

ANSI IEC BS DIN JIS


MC96.1 584-3 1843 43714 C1610

Thermocouple
type

+ + + + +
J, L
– – – – –

+ + + + +
K
– – – – –

+ + + + +
T
– – – – –

PT100 reference table temperature – resistance (EN 60751)


0 –10 –20 –30 –40 –50 –60 –70 –80 –90
°C
Ohm
–200 18.49 14.45 10.49 6.99 4.26 2.51
–100 60.26 56.19 52.11 48.00 43.88 39.72 35.54 31.34 27.10 22.83
0 100.00 96.09 92.16 88.22 84.27 80.31 76.33 72.33 68.33 64.30

0 10 20 30 40 50 60 70 80 90
°C
Ohm
0 100.00 103.90 107.79 111.67 115.54 119.40 123.24 127.08 130.90 134.71
100 138.51 142.29 146.07 149.83 153.58 157.33 161.05 164.77 168.48 172.17
200 175.86 179.53 183.19 186.84 190.47 194.10 197.71 201.31 204.90 208.48
300 212.05 215.61 219.15 222.68 226.21 229.72 233.21 236.70 240.18 243.64
400 247.09 250.53 253.96 257.38 260.78 264.18 267.56 270.93 274.29 277.64
500 280.98 284.30 287.62 290.92 294.21 297.49 300.75 304.01 307.25 310.49
600 313.71 316.92 320.12 323.30 326.48 329.64 332.79 335.93 339.06 342.18
700 345.28 348.38 351.46 354.53 357.59 360.64 363.67 366.70 369.71 372.71
800 375.70 378.68 381.65 384.60 387.55 390.48

PT 100 tolerance class definition


Temperature range of validity [°C]
Tolerance class Tolerance values [°C]
Wire wound resistors Film resistors
AA –50 ÷ +250 0 ÷ +150 ± (0,1 + 0,0017 × | t |)
A –100 ÷ +450 –30 ÷ +300 ± (0,15 + 0,002 × | t |)
B –196 ÷ +600 –50 ÷ +500 ± (0,3 + 0,005 × | t |)
C –196 ÷ +600 –50 ÷ +600 ± (0,6 + 0,01 × | t |)

IP rating
Type Order code IP rating (IEC 60529) Type Order code IP rating (IEC 60529)
E52-ETT_-A IP45 Surface temperature E52-ET_S_-B IP44
Smooth tube type E52-ETJ_-A (IP65*1) Environmental tem-
E52-EPE_-B IP66
PRO E52-ETK_-A (IP67, IP68*2) perature
E52-EP_-B IP67, IP68 ES1B IP65
Contact free
E52ELTJ_-A ES1C IP67
*1
Smooth tube type LITE E52-ELTK_-A IP45 Models with fluoro polymere outer cable sheath and IP65 rating are
available. Contact your Omron representative
E52-ELP_-A *2
Models with IP67, IP68 protective structure are available. Contact your
Bayonet mounting E52-E_-B-_-B IP67, IP68 Tube Omron representative.
IP68 Tube
Enclosed terminals E52-E_-T2-B
IP66 Terminal head

5
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.

Warranty and Limitations of Liability

WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR


FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE


OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.

At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:

• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.

• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.

ERRORS AND OMISSIONS


The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

Cat. No. H10E-EN-03 In the interest of product improvement, specifications are subject to change without notice.

OMRON EUROPE B.V.


Wegalaan 67-69,
NL-2132 JD, Hoofddorp,
The Netherlands
Phone: +31 23 568 13 00
Fax: +31 23 568 13 88
industrial.omron.eu