Concrete Slope Protection Specifications
Concrete Slope Protection Specifications
Drainage of the bed course or backfill shall be provided as shown on the Plans or as required by the Engineer.
2. STRUCTURAL CONCRETE
Structural Concrete shall consist of furnishing, bending, placing, and finishing concrete in all structures except pavements in accordance with this Figure A1
Specification and conforming to the lines, grades, and dimensions shown on the Plans. Concrete shall consist of a mixture of Portland Cement, fine EL. 9.10
aggregate, coarse aggregate, admixture when specified, and water mixed in the proportions specified or approved by the Engineer.
Proportioning and Strength of Structural Concrete The concrete materials shall be proportioned in accordance with the requirements for each class of
concrete as specified in Table 405.2, using the absolute volume method as outlined in the American Concrete Institute (ACI) Standard 211.1. 2-16mm Ø Bottom Bar
"Recommended Practice for Selecting Proportions for Norma Land Heavyweight Concrete". Other methods of proportioning may be employed in the mix w/ 10mm Ø straight bar
design with prior approval of the Engineer. A change in the source of materials during the progress of work may necessitate a new mix design. stirrup
100
40
Ratio Aggregate x 300 Concrete 10mm Ø straight Bar Stirrup
70
Cylinder Specimen 2-16mm Ø Bottom
See Dowel
40
40 kg
100
Square Opening at 28 days
10 mm Ø U-stirrup sp. @ 30cm O.C. Bar w/ 10mm Ø
( bag ** ) kg/kg mm(inch.) Bar Detail straight bar stirrup
Std. mm MN/m(2psi)
2-10 mm Ø Extra Bar STD. STEEL SHEET
H
364 0.53 50-100 37.5 - 47.5 20.7 PILE (400mm x 100mm 10mm Ø Stirrup
A
(9.1bags) (2-4) (1-1/2" - No. 4 ) (300) x 10mm x 6.0m length sp. @ 30cm O.C.
6.0m STEEL SHEET SKSP TYPE II)
STD. STEEL SHEET
* The measured cement content shall be within plus or minus 2 mass percent of the design cement content PILE
PILE (400mm x 100mm
** Based on 40 kg 2-10mm Ø Straight Bar
x 10mm x 6.0m length
SKSP TYPE II)
3. REINFORCEMENT
a. Bars shall be intermediate grade fy=275Mpa. SECTION PERSPECTIVE OF PILE CAP REBARS
b. Standard hooks shall be complied with at the free end of bar equivalent to 90 bend plus 12db and minimum diameter for bends shall be 6db.
c. Splicing of bars shall be by lapping or butt welding at 20 bar Ø or a minimum of 30cm.
d. Adjacent bar shall be securely held together by #16 tie-wires, each having a minimum length of 25cm.
e. Clear concrete cover between reinforcement bars and embankment materials shall be 75mm and precast mortar blocks should be provide for this purpose.
f. Bar reinforcement for concrete structures, except No. 2 bars shall be deformed in accordance with AASHTO M 42, M 31 and M 53 for Nos. 3 through 11. DOWEL BAR DETAIL
BLOW UP DETAIL "A"
g. Dowel and tie bars shall conform to the requirements of AASHTO M 31 or AASHTO M 42 except that rail steel shall not be used for tie bars that are to be bent and SCALE 1 :25 MTS. SCALE 1 :50 MTS.
restraightened during construction. Tie bars shall be deformed bars. Dowel bars shall be plain round bars. They shall be free from burring or other deformation PERSPECTIVE VIEW OF DOWEL PLAN
restricting slippage in the concrete. Before delivery to the site of the work, a minimum of one half (21) the length of each dowel bar shall be painted with one coat of SCALE NDTS
approved lead or tar paint.
h. The sleeves for dowel bars shall be metal of an approved design to cover 50 mm (2 inches), plus or minus 6.3 mm of the dowel, with a closed end, and with a
i.
j.
suitable stop to hold the end of the sleeve at least 25 mm (1 inch) from the end of the dowel. Sleeves shall be of such design that they do not collapse during
construction.
Plastic coated dowel bar conforming to AASHTO M 254 may be used.
The minimum clear spacing between parallel bars in a layer must be db but not less than 25 mm.
PILE CAP DETAIL AT END SILL
4. MIXING WATER
a. Water to be used shall be clean and free from injurious amounts of oil, acid alkali, salt, organic materials and substances that may be deleterious to concrete or
(BLOW UP DETAIL " B " ) 100 40
reinforcement. SCALE 1 :25 MTS. 175
b. Non-potable water shall be used unless it passes equivalent strength of at least 90% of the strength results of similar samples made using potable water with 50mm Ø PVC drain pipe
same proportions through compressive strength tests 9ASTM C109). 45° Elbow- 50mm Ø 50mm Ø PVC Pipe
End Sill EL. 9.10 PVC Pipe (S-1000) (S-1000)
4.1 STORAGE OF CEMENT AND AGGREGATES
4.2 SAMPLING AND TESTING OF STRUCTURAL CONCRETE EL. 8.70
As work progresses, at least one (1) sample consisting of three (3) concrete cylinder test specimens, 150 x 300mm 96 x 12 inches), shall be taken from each 2-16mm Ø Bottom bar w/
seventy five (75) cubic meters of each class of concrete or fraction thereof placed each day. 2-16mm Ø Bottom Bar
Rubble masonry w/ 10mm Ø straight Bar Stirrup
w/ 10mm Ø straight bar
180
Compliance with the requirements of this section shall be determined in accordance with the following standard methods of AASHTO:
90
stirrup 211kg/[Link]. conc. 100mm Ø PVC Pipe
Sampling of fresh concrete 2-12 mm Ø Extra Bar
binder (S-1000)
Weight per cubic meter and air content (gravi-metric) of concrete
10mm Ø 2-16mm Ø Bottom bar w/
Sieve analysis of fine and coarse aggregate
Stirrup ssp. @ 30cm O.C. 10mm Ø straight Bar Stirrup
Slump of Portland Cement Concrete
50
2-12mm Ø
See Dowel Bar Detail
Extra Bar
5. STEEL SHEET PILE 10 mm Ø U-stirrup sp. @ 30cm O.C.
6.0m SKSP TYPE II 3/8" Ø
100 mm Ø PVC HOR. PIPE DRAIN W/ 3/8" Ø PERFORATED SP. 1 AT
5.1 Alignment and grade are subject to adjustment to suit existing field condition. 2-10 mm Ø Extra Bar
5.2 Distance are in centimeters and elevations are in meters unless otherwise specified. 2-16mm Ø Bottom PERFORATED SP. 1 AT QTR. POINTS QTR. POINTS
5.3 All works shall comply with the NIA Standard Specifications pertaining to this project. Bar w/ 10mm Ø STAGG. AT 45° STAGG. AT 45°
straight bar stirrup 6.0m SKSP TYPE II
5.4 All concrete to be used for the other structures should have a minimum compressive strength
of 3500 PSI at 28 days. 30 cms THK. 3/4" - 1 1/2" COARSE AGG
45°
5.5 All reinforcement to be used shall be GRADE 40 steel. 10mm Ø Stirrup 100mm x 50 mm Ø
5.6 All SHEET PILES to be used should be HOT-ROLLED STEEL SHEET PILES with minimum sp. @ 30cm O.C. PVC TEE Pipe
15 cms THK. 3/16" - 3/4" COARSE AGG (S-1000)
thickness of 10.50mm, effective width of 400mm, effective height of 100mm and unit weight of
48kg/m FY36 (Refer to Table 'A'). 15 cms THK. FINE AGG - CONC. SAND
5.7 The materials for the embankments shall not contain any stump, brush, weed, root, turf, clod DRAIN PIPE DETAIL
and other organic matter, clay or other materials shall be broken and beaten and no 2-10mm Ø Straight Bar
SECTION OF PILE CAP REBARS
accumulations at the foot of side slopes of embankment will be permitted.
PERSPECTIVE OF PILE CAP REBARS 15 cms THK. FINE AGG - CONC. SAND
CONSTRUCTION REQUIREMENT
30 cms THK. 3/4" - 1 1/2" COARSE AGG
Sheet pile shall be driven to elevation shown on the plans or as directed by the engineer. Where impractical to drive to plan elevation due to subsurface
conditions, the driving of piles may be stopped at a higher elevation with the written permission of the engineer. However, before granting such permission, the
engineer shall ascertain that the contractor has adequate equipment for the required driving and that piles can be driven to the plan elevation with the proper use
BLOW UP DETAIL "B" 15 cms THK. 3/16" - 3/4" COARSE AGG