All rights reserved. Printed in the Peoples Republic of China. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise without the prior written consent of Maipu Communication Technology Co., Ltd. Maipu makes no representations or warranties with respect to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose. Further, Maipu reserves the right to revise this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or changes. Maipu values and appreciates comments you may have concerning our products or this document. Please address comments to:
All other products or services mentioned herein may be registered trademarks, trademarks, or service marks of their respective manufacturers, companies, or organizations.
Document History
Date 20/09/2007 Revision No. R1.0 Description The MP1700E Series Installation Manual V1.4 provides information about the installation of routers designed and developed by Maipu Communication Technology Co., Ltd
Page 2 of 49
Presentation: (Introductions, procedures, illustrations, completeness, arrangement, appearance) Good Fair Average Poor Accessibility: (Contents, index, headings, numbering) Good Fair Average Poor Editorial: (Language, vocabulary, readability, clarity, technical accuracy, content) Good Fair Average Poor
Please check suggestions to improve this document: Improve introduction Make more concise Improve Contents Add more step-by-step procedures/tutorials Improve arrangement Add more technical information Include images Make it less technical Add more detail Improve index
If you wish to be contacted, complete the following: Name Postcode Telephone Company Address Email
Page 3 of 49
Contents
Modules.................................................................................................... 19
Sync/Async Serial Interface Module (SAE) Series..................................................... 19
1-port High-speed V.24/V.35 Serial Module (1SAE).................................................................19 1SAE Interface Module ..........................................................................................................20 1SAE interface module connected cable..................................................................................20 1SAE Interface Attributes.......................................................................................................20
Page 4 of 49
Page 5 of 49
Page 6 of 49
Installation Manual
Purpose
The MP1700E Series Installation Manual V1.4 provides technical information to understand the installation issues of the routers. The document provides right answers to your technical queries.
Customer Support
If you have problems or questions regarding your product, please contact us by e-mail at overseas@maipu.com. You can also call our International Business Department over +8628-85148850, 85148041, 85148050, 85148750, and 85148997.
Documentation Support
Maipu Communication Technology Co., Ltd welcomes comments and suggestions on the document usefulness. For further queries or suggestions, contact us by e-mail overseas@maipu.com or fax comments to +86-28-85148948. You can visit our website at http://www.maipu.com, which comprises interesting subjects such as product knowledge base, sales & support, and the Maipu news.
Page 7 of 49
Overview
MP1700E router is highly beneficial for finance, telecom, tax, and public security industries and large & medium enterprises. The routers provide a series of highly efficient and low cost network interconnection solution for integration and powerful functions. The router supports: Internet connection Multi-service data integration Branch dialup & backup service Internet & Extranet access
Page 8 of 49
Product Features
High performance & reliability The MP1700E series router CPU provides high performance and RISC communication processor. The software adapts high performance and reliable RTOS and network program design. High port integration - The MP1700E series router has two fixed 10/100M fast Ethernet ports, one high-speed asynchronous interface (1SAE), and voice card and MIM slots. It has powerful multi-port access performance, which provides high price-performance ratio network solution. Modular system structure - The MP1700E series router adapts modular system, which provides different interface configuration. They support various optional interface modules and interface cards, and customers choose different extending interfaces and modules such as Ethernet interface, sync/async interface, asynchronous interface, E1/CE1 interface, ISDN-U IST interface, baseband MODEM, frequency band MODEM and VOP/VOS interface. They also support the site upgrade of all core software and modular components. Routing/transmission integration - The MP1700E series router integrates CSU/DSU, sync 33.6K MODEM, asynchronous 33.6K MODEM, ISDN NT1 and ISDN TE into router to provide required solutions. Universality - The MP1700E series router supports a series of Internet protocol standard (RFC) and international communication network standard.
Page 9 of 49
Structure - The hardware design adapts lower power consumption design and integrated structure design, which has powerful performance on radiation and EMC.
Page 10 of 49
Hardware Features
MP1700E router
Page 11 of 49
Indicators from left to right: SYS & PWR (system and power supply indicator) SYS - System status indicator. It shines fast when system is loading, and after that it shines slowly PWR - System power supply indicator, and it is on after power on. SLOT1 (slot 1 status indicator) ACT - voice card module data indicator RDY - voice card module link status indicator SLOT 0 (slot 0 status indicator) ACT - inserted module data indicator RDY - inserted module link status indicator SA (fixed sync/async serial status indicator) ACT - sync/async serial data indicator LINK - sync/async serial link status indicator CONSOLE (console port) TXD - console port data sending indicator RXD - console port data receiving indicator ETHERNET1 (Ethernet interface1) 100M - 10/100M Ethernet interface data rate indicator. On: 100Moff: 10M ACT - Ethernet interface data indicator ETHERNET0 (Ethernet interface 0) 100M - 10/100M Ethernet interface data rate indicator. On: 100M/off: 10M ACT - Ethernet interface data indicator
Page 12 of 49
S/A
SLOT1 is voice card module slot for VOP/VOS series module; SLOT0 is MIM slot, adopting modularization design, and its function can be realized according to different interface card and relevant software modules.
Page 13 of 49
MP1700E System
MP1700E router basic configuration and working environment:
Item Console port Ethernet interface SA interface Voice card slot MIM slot Processor FLASH SDRAM Dimension (WDH) Power supply input voltage Environment Temperature Environment humidity Power supply rating power Maximum power consumption Description One fixed, async DTE working mode (RJ45) Two fixed 10/100Mbps fast Ethernet (RJ45) One fixed high-speed async/sync interface (DB25) One voice card SLOT1 MIM SLOT0, supports various modules High performance PowerPC processor 8MB 64MB 34023044 (mm) AC: 100 240V 50/60HzDC: 4057V - only MP1700E supports. AC/DC. 0-40 10-90%. Non-condensing 45W 15W
MP1700E router doesnt have asynchronous interfaces with modular and clip design.
Page 14 of 49
Product Functions
MP1700E functions, supported protocols & services:
Supported protocols & Services Network protocol Description WAN supports: PPP PPP compression SLIP CSLIP Frame relay Frame relay switching X.25 X.25 switching HDLC LAPB ISDN LAN is Ethernet network, and it supports two kinds of link layer frame format: Ethernet-II Ethernet-SNAP Dialup network MODEM dialupcall in/call out CALLBACK Dialup on demand Dialup backup Routing protocol Static routing Dynamic routing: RIPv1 RIPv2 OSPF BGP IRMP (compatible with CISCO EIGRP protocol) SNSP (compatible with CISCO ODR protocol) Dial-on-demand routing (DDR) Policy routing Multicast: IGMP PIM-SM PIMDM DVMRP Hot backup: VRRP VBRP (compatible with CISCO HSRP protocol) Network service ARP
Page 15 of 49
Proxy ARP L2TP Configuration command protection IP packet filtering firewall IP UNNUMBERED IP policy routing DHCP relay PAP/CHAP check EASY IP NAT network concealing RADIUS check IPSEC data encryption IKE GRE Load balance MPLS QoS service PQ CQ WFQ CBWFQ LLQ WRED CAR SNMPv1, SNMPv2, SNMPv3 Supporting standard network management (fully compatible with CISCO) Configuration via Console port Local or remote login via local Telnet Configuration command security isolation function Chinese/English prompting and help information Debugging information, for troubleshooting. Login and managing other products via Telnet Download and upload configuration file and application program by FTP Download and upload configuration file and application program by TFTP Colorful distributing debugging information Log function IP packet filtering firewall, PAP/CHAP, MD5, NAT, RADIUS, TACACS, IPsec data encryption
Network management
Security
Page 16 of 49
Working mode
Page 17 of 49
Slot MP1700E series router has two slots: SLOT0 and SLOT1. SLOT0 is MIM module slot, and it supports Ethernet interface module, sync/async interface module, asynchronous interface module, E1/CE1 interface module, U interface module, ST interface module, baseband MODEM interface module, frequency band MODEM module, VOP/VOS module. It is compatible with MP17XXMP26XX series router function module. SLOT1 is voice card slot for VOP/VOS card module, which can access any telephone via dialup or second dialup; you can realize free phone call in network by IP network.
Page 18 of 49
Modules
MP1700E router is modular router and provides two slots. SLOT1 is voice card slot for VOP and VOS series voice modules. SLOT0 is MIM slot compatible with all serial interface modules. Supported modules are 1SAE, 1CE1, 1E1, 1M336, 1M128, 1U, 1VOP, 2VOP, 1VOS, 2VOS, 1ETE, 1ST and 8AX.
Page 19 of 49
Page 20 of 49
Page 21 of 49
Non-channelized E1 Series
1-port Non-channelized E1 (1E1)
1port non-channelized E1 module provides a data transmission port with 2.048Mbit/s bandwidth. E1 is same as CE1, it can be divided into 32 timeslots, and timeslot 0 of E1 can be used to transmit data in unframed mode, to realize 2M transparent transmission.
1 E 1 I n t e r f a ce M o d u l e & Ind i c a t o r
1E1 interface module:
Page 22 of 49
1 E 1 I n t e r f a ce C o nne c t e d C a b l e
1E1 and BNC pin coaxial cable and RJ45-RJ45 straight connected twistedpair cable.
1 E 1 I n t e r f a ce A t t r i b u t e s
1E1 interface attributes: 1-port non-channelized E1 (1E1) attributes:
Attributes Interface Interface number Interface standard Supported service Supported protocol Description BNC 1 group G.703 X.25 FR PPP HDLC
Page 23 of 49
1-port 33.6K frequency-band MODEM (1M336) DIP switch: 1-port 33.6K frequency-band MODEM (1M336) DIP switch:
Mode Frequency-band MODEM mode Console port mode DIP switch 1 OFF ON 2 OFF OFF LINE is used as inbuilt frequency-band MODEM interface. LINE is used as CONSOLE port. Description
Page 24 of 49
1-port 128K baseband MODEM (1M128) Indicator description: 1-port 128K base-band MODEM (1M128) indicator:
ACT
B1 B2
Page 25 of 49
Page 26 of 49
1U Interface Attributes
1U interface attributes: 1-port ISDN U module (1U) interface attributes:
Attributes Tie-in Interface number Supported link protocol Supported network protocol Description RJ45 1 PPP IP
Page 27 of 49
1-port VoIP module (1VOP) indicator: V1 V2 VoIP module indicator. The LED is on during the call. 1VOP module may not have this LED, and if it has, the LED will be not on.
1 V O P M o d u l e C o nne c t e d C a b l e
1VOP module connected cable is RJ45 (4, 5 signal line) and RJ11 telephone line.
Page 28 of 49
1 V O P Int e r f a c e A t t r i b u t e s
1-port Voice module (1VOP) interface attributes: Attributes Interface Interface number Supported protocol Description RJ45 jack 1 H.225 H.245 RTP RTCP G.711 G.723 G.729
2-port VoIP module (2VOP) indicators: V1 V2 VoIP module indicator. LED on: after pickup, during the call. VoIP module indicator. LED on: after pickup, during the call.
2 V O P M o d u l e C o nne c t e d C a b l e
2VOP module connected cable is RJ45 external cable.
Page 29 of 49
1-port switch VoIP module (1VOS) Indicator description: 1-port switch VoIP module (1VOS) indicator: V1 V2 VoIP module indicator. LED on: During the phone call. 1VOS module may not have this LED. Otherwise, the LED will never be on.
Page 30 of 49
1 V O S M o d u l e C o nne c t e d C a b l e
1VOS module connected cable is RJ45 (4, 5 signal line) and RJ11 cable.
1 V O S I n t e r fa c e A t t r i b ut es
1-port switch VoIP module (1VOS) interface attributes: Attributes Interface Interface number Supported protocol Description RJ45 jack 1 H.225 H.245 RTP RTCP G.711 G.723 G.729
Page 31 of 49
Indicator description: 2-port switch VoIP module (2VOS) indicator: V1 V2 VoIP module indicator. LED on: during the phone call VoIP module indicator. LED on: during the phone call
2 V O S M o d u l e C o nne c t e d C a b l e
2VOS module connected cable is RJ45 external cable.
Page 32 of 49
1-port Ethernet module (1ETE) 1-port switch VoIP module (1ETE) indicator: LINK Tx Rx On: link connected LED Blinking: data transmit LED Blinking: data receive
1 E T E M o d u l e C o nne c t e d C a b l e
RJ45 cable.
Page 33 of 49
1-port ISDN S/T module (1ST) indicator: ACT B1 B2 Active indicator, and it is on when it operates normally. B1 channel indicator. The indicator on when using Channel B1, B1=64K or B1+B2=128K B2 channel indicator. The indicator on when using Channel B2, B2=64K or B1+B2=128K
1 S T M o d u l e I n t e r fa c e A t t r i b ut es
1-port ISDN S/T module (1ST) interface attributes: Attributes Tie-in Number Supported protocol Description RJ45 1 PPP
Page 34 of 49
System Installation
Preparation
Read the manual Place router on a safe flat surface Do not put heavy material on router Use UPS Ensure proper grounding
Environment Requirements
Operati ng Environment
To ensure good working of router, maintain stable temperature and humidity. Always place router in the equipment room. The environment requirements are: Environment temperature: 040C Humidity: 1090%. Non-condensing Around the ventilation, the space should be no less than10cm. We suggest installing router on 19-inch standard rack.
Page 35 of 49
Dust-free Environment
Dust is harmful for router operation. Dust causes static absorption. Dust damages the router especially when the temperature and humidity are lower.
7 8
1 1
Page 36 of 49
Chassis Installation
Tools & Equipment
Tools: Screwdriver Anti-static equipment Connected cables: Console port cable Ethernet cable (MP1700E Ethernet cable is configured according to the number of Ethernet modules) Modular interface cable Equipment: Ethernet 10 BASE-T HUB Configuring terminal (can be PC) Equipment relevant to optional module
Page 37 of 49
Machine Installation
The dimension of MP1700E is 340mm x 230mm x 44mmWDHand its installation process is: Step 1: Fix angle iron on front panel or back panel sides with bolts Step 2: Place router on empty slot Step 3: Fix angle iron to slots with bolts Step 4: Bracket and fixed angle iron will be fixed on the rack
Ground wire
Naught wire
Power supply jack
Live wire
Page 38 of 49
Connecting power supply: Put power supply switch to OFF, and then connect one side of power supply cable to the entry of back panel of router, and another side to power supply jackAC: 220V 50Hz/60Hz, DC: -48V, only MP1700E supports Put power supply switch to ON Check whether the power supply lamp of front panel is on, if not, please repeat step one and two.
Page 39 of 49
Module Installation
The routers adapt modular system structure and different kinds of interface configuration. Module installation steps: Step 1: Choose the module and interface. Step 2: Inset the module to slot. Insert the module circuit board into interface card slot. Step 3: Push in the module close to back panel. Step 4: Tighten the screw.
Rack/Desk
Installing routers to 19-inch standard rack: Front-end installation method: Step 1: Install ear bracket to both sides of front-end of MP1700E and fix with screw. Step 2: Place router on standard rack and connect bracket and metal frame with screw.
Page 40 of 49
Hardware Installation
Complete machine installation according to the details, and make sure the power supply switch is OFF Connect one side of AC power supply cable to router power supply, and another side to power supply jack Configure the router through console port after first power on Insert one side of configuration cable to console port, and another side to PC or terminal serial Insert one side of Ethernet cable to LAN interface, and another side to LAN Connect sync/async communication cable to router WAN Interface MP1700E sync/async interface can work in the mode of V.24/V.35, and these two modes are completed by V.24/V.35 button In V.24 mode, interface adopts standard RS232 cable connection In V.35 mode, interface adopts special V.35DTE cable
V.24/V.35 cable
Page 41 of 49
Rate
and
transmission
distance:
Sync/async
serial
supports
different signal standards and baud rates in different working modes. Choose cables as per prevailing conditions.
Page 42 of 49
V.24 cable rate and transmission distance: Baud rate (bps) 2400 4800 9600 19200 38400 64000 115200 Maximum transmission distance (m) 60 60 30 30 20 20 10
V.35 cable rate and transmission distance: Baud rate (bps) 2400 4800 9600 19200 38400 56000 64000 2048000 Maximum transmission distance (m) 1250 625 312 156 78 60 50 30
Page 43 of 49
Step 3: After power on, check indicator status on 1SA module panel. DCD on: Link connected
Page 44 of 49
Page 45 of 49
Page 46 of 49
RJ45 cross cable (type-5 twisted-pair) pin configuration RJ45 1 2 3 6 4 5 7 8 Signal TX+ TXRX+ RX--------Direction > > < < --------RJ45 3 6 1 2 7 8 4 5 Length 2m
Page 47 of 49
5 4 3 2 1 9 8 7 6
RJ45 jack
CONSOLE RJ45 1 2 3 4 5 6 7 8
DB9 8 6 2 5 --3 4 7 1 9
Length 3m
Page 48 of 49
Page 49 of 49