AIR CONDITIONING AND HEATING EQUIPMENT
SAFETY SUMMARY
GENERAL SAFETY NOTICES The following general safety notices supplement the specific warnings and cautions appearing elsewhere in this manual. They are recommended precautions that must be understood and applied during operation and maintenance of the equipment covered herein. The general safety notices are presented in the following three sections labeled: First Aid, Operating Precautions and Maintenance Precautions. A listing of the specific warnings and cautions appearing elsewhere in the manual follows the general safety notices. FIRST AID An injury, no matter how slight, should never go unattended. Always obtain first aid or medical attention immediately. OPERATING PRECAUTIONS Always wear safety glasses. Keep hands clear of the evaporator blower and condenser fan. No work should be performed on the unit until all circuit breakers and start--stop switches are turned off, and power supply is disconnected. Always work in pairs. Never work alone. In case of severe vibration or unusual noise, stop the unit and investigate. MAINTENANCE PRECAUTIONS Beware of unannounced starting of the evaporator blower & condenser fan. Do not remove the ceiling grill assembly or the upper unit cover assembly before turning the power off, and disconnecting the power supply. Before disconnecting, discharge capacitors by shorting across the capacitors terminals. (See Paragraph 3.5.8) When disassembling wiring, use numbered stickers to identify wire leads and terminals. This aids in quick, accurate reassembly. Be sure power is turned off before working on motors, controllers, or electrical control switches. Tag any circuit breakers and power supply to prevent accidental energizing of circuits. Do not bypass any electrical safety devices, e.g. bridging an overload, or using any sort of jumper wires. Problems with the system should be diagnosed and any necessary repairs must be performed by qualified service personnel. In case of electrical fire, open circuit switch and extinguish with CO2 (never use water). Use dry nitrogen to pressurize the system for leak checking. Be careful not to exceed 150 psig test pressure in the hermetic compressor. Coil fins are sharp. Use care when removing the cover form the base pan to avoid personal injury. Oil vapor in piping stubs can ignite from torch flame and cause serious injury. Exercise extreme care when brazing, and keep brazing cloth and fire extinguisher handy for emergency use. Disconnect power to the AirV unit before checking the capacitor.
Safety-- i
T-298
SPECIFIC WARNING AND CAUTION STATEMENTS The statements listed below are applicable to the refrigeration unit and appear elsewhere in this manual. These recommended precautions must be understood and applied during operation and maintenance of the equipment covered herein. SPECIFIC WARNINGS AND CAUTIONS
WARNING
Be sure to observe warnings listed in the safety summary in the front of this manual before performing maintenance on the AirV system
WARNING
Before working on the unit be sure to first disconnect all electric power to the unit to avoid the possibility of electrical shock and personal injury. Before disconnecting, discharge capacitors by shorting across the capacitors terminals (Refer to paragraph 3.5.8)
WARNING
Shield coils with cardboard to protect hands against injury from sharp metal edges when removing compressor and other components.
WARNING
Oil vapor in piping stubs can ignite from torch flame and cause serious injury. Exercise extreme care when brazing, and keep brazing cloth and fire extinguisher handy for emergency use.
WARNING
Disconnect power to the AirV unit before checking the capacitor.
WARNING
Do not touch the metal of the screwdriver when discharging the capacitor. You could receive a shock.
WARNING
Before installing thermostat, turn off all power to unit. There may be more than one power disconnect. Electrical shock can cause personal injury or death.
CAUTION
Do not use carbon tetrachloride, solvents, or waxes containing solvents to clean plastic sections. T--298 Safety-- ii
CAUTION
Coil fins are sharp. Use care when removing the cover form the base pan to avoid personal injury.
CAUTION
The change from Fahrenheit to Celsius will be permanent. It cannot be changed back to Fahrenheit.
CAUTION
When re-assembling, ensure the battery springs are correctly placed in the battery spring holders.
CAUTION
Improper wiring or installation may damage thermostat. Wiring must conform to local and national electrical codes.
Safety-- iii
T-298
TABLE OF CONTENTS
PARAGRAPH NUMBER DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 1.2 1.3 1.4 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SERIAL NUMBER IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DESIGN CHANGE DESCRIPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AirV SYSTEM COMPONENT SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.1 Refrigerant Charge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.2 Compressor - 115 Volts, 60 Cycles, 1 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.3 Compressor - 220 Volts, 50 Cycles, 1 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4.4 Thermostat Range (All Free Blow Units) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 1.6 1.7 START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE-STANDARD SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE - HEAT PUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7.1 Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7.2 Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 NO POWER TO UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DUCTED UNIT WILL NOT OPERATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DUCTED UNIT WILL NOT COOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COMPRESSOR POWER SUPPLY OPEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COMPRESSOR RUNS BUT CYCLES, FAN OPERATING ERRATICALLY . . . . . . . . . . . . . . . . . . . . CYCLES ON COMPRESSOR OVERLOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSUFFICIENT COOLING, COOLING AIR NOT ADEQUATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONDENSER AIR NOT ADEQUATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSUFFICIENT COOLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1-1 1-1 1-1 1-1 1-9 1-9 1-9 1-9 1-9 1-9 1-9 1-10 1-10 1-11 2-1 2-1 2-1 2-1 2-1 2-1 2-2 2-2 2-2 2-2 2-2 2-2 2-2 2-2 2-3 2-3 2-3 3-1 3-1 3-1 3-1 3-1 3-1 3-2 3-2 3-2 3-3 3-3 3-3
2.10 COMPRESSOR FLOODING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.11 HEATER CYCLES ON LIMIT SWITCH (HEAT/ COOL VERSION ONLY) . . . . . . . . . . . . . . . . . . . . . 2.12 AIR SWEEP NOT WORKING (FREE BLOW VERSION ONLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.13 WATER LEAKAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.14 INADEQUATE HEAT (FREE-BLOW HEAT ONLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.15 INADEQUATE HEAT (HEAT-PUMP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clearing Diagnostic Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SERVICE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1 3.2 3.3 PREVENTATIVE MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SERVICE - GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CEILING UNIT - FREE BLOW SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.1 Filter Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.2 Ceiling Grill Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.3 Ceiling Panel Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.4 Master Control Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.5 Air Sweep Switch Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.6 Indoor Thermostat Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.7 Air Sweep Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3.8 Heat Strip Assembly Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
T--298
LIST OF FIGURES
FIGURE NUMBER Figure 1-1 Model/Serial Number Plate (Typical) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-2 Roof Unit Component Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-3 Ceiling Unit Component Identification (Free-Blow) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-4 Component Identification - Low Profile - Upper Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-5 Component Listing-Ceiling Unit For Ducted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-6 Ducted System Air Flow Arrangement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-7 Serial Number Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-8 Refrigerant Flow Schematic (Standard System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-9 Refrigerant Flow Schematic - Heat Pump - (Cool Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1-10 Refrigerant Flow Schematic - Heat Pump - (Heat Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-1 Filter Removal - Free Blow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-2 Ceiling Grill - Free Blow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-3 Ceiling Panel Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-4 Ceiling Panel With Heat Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-5 Control Box Assembly - Free Blow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-6 Indoor Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-7 Air sweep motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-8 Heat Strip Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-9 Filter Removal - Ducted Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-10 Ceiling Grill - Ducted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-11 Control Box & PCB Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-12 Control Box Assembly - Ducted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-13 Main/Display PCBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-14 Cover Assembly - Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-15 Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-16 Control Box Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-17 Water Cover Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-18 Upper Scroll Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-19 Motor Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-20 Spring Clamp Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-21 Motor Clip Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-22 Condenser Fan Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-23 Blower Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-24 Condenser With Motor Assembly & Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-25 Set-Up For Discharging a Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Page 1-1 1-3 1-4 1-5 1-6 1-7 1-8 1-9 1-10 1-11 3-1 3-2 3-2 3-2 3-2 3-3 3-3 3-3 3-4 3-4 3-4 3-5 3-5 3-5 3-6 3-6 3-6 3-7 3-7 3-7 3-7 3-8 3-8 3-8 3-9 T--298
LIST OF FIGURES
Figure 3-26 Cover Assembly - Low Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-27 Upper Scroll Assembly Locking Tabs (b.) & Screw Locations (c.) . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-28 Upper Scroll Assembly Keeper Tab Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-29 Upper Scroll & Control Box Cover Removed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-30 Condenser Fan Assembly & Retaining Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-31 Condenser Fan Motor & Fan Assembly Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-32 Condenser Fan Motor & Fan Assembly Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-33 Condenser Motor Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-34 Evaporator Motor Locking Tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-35 Evaporator Motor/Blower Assembly In Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-36 Evaporator Blower Wheel (Flush With End Of Motor Shaft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-37 Control Box Assembly With Capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-38 Remote Control Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-39 Remote Control PCB (FR9 Location) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-40 Wall Thermostat Wiring Diagram - Cool Only Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3-41 Wall Thermostat Wiring Diagram - Heat/Cool Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-1 Upper Unit Schematic - Standard & HC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-2 Upper Unit Schematic - Low Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-3 Ceiling Unit Schematic - Cooling Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-4 Ceiling Unit Schematic - Heat/Cool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-5 Ceiling Unit, Standard - Ducted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-6 Heat Pump - Upper Unit - Free Blow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-7 Heat Pump - Ceiling Unit - Free Blow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-8 Heat Pump - Upper Unit - Ducted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4-9 Heat Pump - Ceiling Unit - Ducted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 3-10 3-10 3-11 3-11 3-11 3-11 3-12 3-12 3-12 3-13 3-13 3-14 3-14 3-17 3-18 4-1 4-1 4-2 4-2 4-2 4-3 4-3 4-4 4-4
LIST OF TABLES
TABLE NUMBER Page Table 1-1 Model Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Table 1-2 Additional Support Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Table 2-1 System Self-diagnostics Function (Ducted Remote) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
T--298 iv
SECTION 1 DESCRIPTION
1.1 INTRODUCTION
MODEL No.
This manual contains service instructions and electrical data for the AirV, Carrier Transport Air Conditionings Recreational Vehicle air conditioning unit. The AirV units are two piece systems, consisting of the Upper Unit and the Ceiling unit. The Upper Unit contains the refrigeration system while the Ceiling Unit contains the controls and vents. The Ceiling Units are available in a free--blow or ducted configuration. The free--blow units (see Figure 1-2) deliver air to the vehicle by means of front and rear end vents and one downward vent (air shower). The vents may all be opened or closed to direct air as desired. The front and rear vents are fitted with motorized dampers that oscillates to produce an air--sweep effect. These units may be fitted with optional electric heat. The ducted units (see Figure 1-5 and Figure 1-6) deliver air through ducting built in the vehicle ceiling. These units are fitted with a 12 VDC microprocessor control system, a display panel (PCB display) and a remote controller. These units may be wired to provide thermostatic control of the vehicle furnace. Carriers AirV air conditioning models include cooling only units, heating/cooling units, and heat pump units. The cooling only units are available with free blow or ducted air delivery. Cooling units with heat strips are available for free blow only. Operation of the AirV units is controlled automatically by the temperature controller (thermostat), which maintains the vehicles interior temperature at the desired set point. Free Blow, cool--only units are available with a wall mounted thermostat. Table 1-1 lists model numbers and descriptions of the AirV units, and Table 1-2 lists additional support manuals that are available. 1.2 SERIAL NUMBER IDENTIFICATION Separate part numbers and serial numbers are provided for the upper and lower unit assemblies The numbers may be found on a plate readable from inside the vehicle, See Figure 1-7. The first two numbers of the serial number, see Figure 3-22, is the week the unit was manufactured. For example, 01 would designate the first week of the year and 52 would designate the last week of the year. The third and fourth numbers designate the year in which the unit was manufactured. For example, 99 would represent the year 1999, 00 the year 2000, and so on. The letter Y and all the numbers after it designates the unit serial number. Example: Y43210 A serial number of 1303Y12345 designates that the unit was manufactured the 13th week of 2003 and the serial number is Y12345.
Carrier
60
Btu/h W A
Air Conditioning C
USE 20 AMP
TIME DELAY FUSE OR CIRCUIT BREAKER
DESIGN PSIG HIGH 350 LO 150 oz R-22 kg COMPRESSOR FAN MOTOR USE CEILING ASSY/ANY RLA FLA
99-00469-01
Figure 1-1 Model/Serial Number Plate (Typical) 1.3 DESIGN CHANGE DESCRIPTIONS The following list provides a description of changes in design and serial number breaks for those changes. 1400Y A diode was added to the Ducted Ceiling assembly control board to stop DC ripple from the converters, 2900Y Cover screw coating was changed in order to eliminate corrosion. 3400Y The plastic shroud was modified to improve drainage. 5100Y A new compressor and capacitor is introduced, improving stability and increasing capacity. 1201Y The temperature sensor was moved to the grill to improve temperature sensing during furnace mode, 2501Y The dual air sweep was added. 4501Y A switch was added to skip compressor malfunction test. 4601Y Change in material was made in order to strengthen the fan propeller. 4901Y The mounting bolt lengths were increased 3/4 inch. 4901Y The polar white ducted ceiling color was cut--in. 0703Y & 1903Y New style PCB -- Cool Mode -- Control & Power Assembly (Fans shut off in auto mode). 0803Y & 2603Y New style PCB -- Heat Pump -- Control & Power Assembly (Fans shut off in auto mode). 4204Y Minimum furnace setpoint lowered from 63F to 45F.
1-1
T--298
Model Number 115V Standard System 68RV14102A 220V Standard System 68RV11302A High Capacity 68RV15102A
Table 1-1. Model Chart UPPER UNIT (ROOF) Part Number Voltage 99--00468--00 115/1/60 99--00468--01 115/1/60 99--00468--02 220/1/50 99--00468--03 220/1/50 99--00468--08 115/1/60 99--00468--09 115/1/60 99--00468--04 115/1/60 (Free Blow) 99--00468--05 115/1/60 (Free Blow) 99--00468--06 115/1/60 (Ducted) 99--00468--07 115/1/60 (Ducted) 99--00468--10 (Free Blow -- High Capacity) 99--00468--12 (Free Blow -- Standard) 115/1/60 115/1/60
Amps 12.8 12.8 5.3 Cool 6.7 Heat 14.5 14.5 12.7 Cool 10.9 Heat 12.7 Cool 10.9 Heat 12.7 Cool 10.9 Heat 12.7 Cool 10.9 Heat 15.1 Cool 13.8 Heat 15.0 Cool 13.7 Heat Options Cool Only Cool Only Heat/Cool Heat/Cool Cool Only Cool Only Cool Only Heat/Cool Cool Only Heat Pump Heat Pump Heat Pump Cool Only Cool Only Heat/Cool Heat/Cool Cool Only Cool Only
Color White Ivory White Ivory White Ivory White Ivory White Ivory White White
LOW PROFILE 68RV15103A LOW PROFILE 68RV14103A Model Number 68RV0010AA 68RV0010BA 68RV0010KA 68RV0030AA 68RV0030BA 68RV0030KA 68RV0012CA 68RV0011LA 68RV0010AB 68RV0010AB 68RV0010BB 68RV0010BB 68RV0040MA 68RV0010DB
Part Number 99--00469--00 99--00469--01 99--00469--02 99--00469--03 99--00469--06 99--00469--04 99--00469--05 99--00469--08 99--00469--10 99--00469--11 99--00469--12 99--00469--13 99--00469--23 99--00469--24 99--00469--25 99--00469--26 99--00469--22 99--00469--29
CEILING UNIT Voltage 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 (12VDC) 220/1/50 220/1/50 220/1/50 220/1/50 115/1/60 115/1/60 115/1/60 (12VDC) 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60 115/1/60
Color White Ivory White Ivory White White Ivory White White White Ivory White White Ivory White Ivory White White
Interface Free Blow Free Blow Free Blow Free Blow Ducted Free Blow Free Blow Free Blow Ducted Free Blow Free Blow Ducted Free Blow Free Blow Free Blow Free Blow Ducted Wall Thermostat Free Blow Wall Thermostat
T--298
1-2
MANUAL-FORM NO. 71LC6A54310 71LH6A54070 71LD6A54070 71LH6A54070 71RQ6A5401A 71DQ6A5401A 71DW6A54070 71LC6A54310 71LH6A54070 71RW6A54310 T--298PL 62--50455--00
Table 1-2 Additional Support Manuals EQUIPMENT COVERED TYPE OF MANUAL AirV 115 Volts--Free Blow (Cool Only) AirV 115 Volts--Free Blow (Heat--Cool) AirV 115 Volts--Ducted (Cool Only) AirV 220 Volts--Free Blow (Heat--Cool) AirV 115 Volts--Free Blow (Heat Pump) AirV 115 Volts--Ducted (Heat Pump) AirV 115 Volts--Ducted Wired Thermostat AirV 115 Volts--Free Blow (Cool Only) AirV 115 Volts--Free Blow (Heat--Cool) AirV 115 Volts--Free Blow Wired Thermostat AirV Basic refrigeration Owners Guide Owners Guide Owners Guide Owners Guide Owners Guide Owners Guide Owners Guide Owners Guide Owners Guide Owners Guide Service Parts Service Training
(For) PART NO. 99--00469--00 99--00469--01 99--00469--02 99--00469--03 99--00469--06 99--00469--08 99--00469--09 99--00469--11 99--00469--12 99--00469--13 99--00469--22 99--00469--23 99--00469--24 99--00469--25 99--00469--26 99--00469--29 ALL ALL
3 4
1. 2. 3.
4. 5.
1. 2.
3. 4.
T--298
1-4
2 3
5 6
10
11
1. 2. 3. 4. 5. 6.
Cover Assembly Scroll Assembly -- Upper Condenser Fan Condenser Motor Evaporator Motor Evaporator Blower Wheel
7. 8. 9. 10. 11.
Condenser Coil Scroll Assembly -- Lower Evaporator Coil Compressor Base Pan Assembly See Figure 1-3 for Ceiling Package (Free--Blow)
Figure 1-4 Component Identification - Low Profile - Upper Unit 1-5 T--298
12 11
10 4 5
9 8
1. 2. 3. 4. 5. 6.
Telescoping Divider (3 different sizes available) Divider Assembly Frame Panel, Insulation Assembly Control Box Assembly Control Box Cover Suction Packing Assembly
Remote Control Assembly Remote Control Bracket Assembly Filter Assemblies (2) PCB Cover PCB Main Assembly PCB Display
Figure 1-5 Component Listing-Ceiling Unit For Ducted Systems T--298 1-6
1 2
SCHEMATIC VIEW
1 5 SUPPLY AIR
INSTALLED VIEW
1. 2. 3. Vehicle Duct System (Connection) 4. Control Box Assembly Telescoping Divider (3 different sizes available) 5. Supply Air Discharge Area Return Air Suction Area Figure 1-6 Ducted System Air Flow Arrangement
1-7
T--298
Upper Unit Serial Number of Ceiling Unit Ceiling Unit (Cover Removed)
Ducted Type
1.4 AirV SYSTEM COMPONENT SPECIFICATIONS 1.4.1 Refrigerant Charge Standard -- High Capacity -- Heat Pump R--22 -- 15.9 Ounces Low Profile (All) R--22 -- 16.9 Ounces 1.4.2 Compressor - 115 Volts, 60 Cycles, 1 Phase a. Locked Rotor Amps - Standard - High Capacity - Heat Pump 64.5 AMPS6 b. Locked Rotor Amps - Low Profile High Capacity 59.0 AMPS c. Fully Loaded Amps - Standard Cooling -- Approximate 12.8 AMPS Heating -- N/A
d. Fully Loaded Amps - High Capacity Cooling -- Approx. 14.5 AMPS Heating -- Approx. 11 AMPS e. Fully Loaded Amps - Low Profile Cooling -- Approx. 14.1 AMPS Heating -- Approx. 13.8 AMPS f. Fully Loaded Amps - Heat Pump Cooling -- Approx. 12.8 AMPS Heating -- Approx. 11 AMPS 1.4.3 Compressor - 220 Volts, 50 Cycles, 1 Phase a. Locked Rotor Amps 23.6 AMPS 1.4.4 Thermostat Range (All Free Blow Units) 61 F (16 C) to 89 F (32 C) 1.5 START-UP Refer to operating instructions in Owners Guide (see Table 1-2) packaged with the vehicle system.
CAPILLARY TUBE
STRAINER
COMPRESSOR
CONDENSER
Figure 1-8 Refrigerant Flow Schematic (Standard System) 1.6 REFRIGERANT CYCLE-STANDARD SYSTEM The cooling cycle is energized when the thermostat, located on the ceiling unit, calls for cooling. The main components of the system are the compressor, air-cooled condenser coil, strainer, capillary tube, evaporator coil and accumulator. The compressor raises the pressure and the temperature of the refrigerant and forces it through the discharge line into the condenser coil. (See Figure 1-8.) The condenser fan circulates surrounding air (which is at a temperature lower than the refrigerant) over the outside of the coil tubes. Heat transfer is established from the refrigerant (inside the tubes) to the air (flowing over the tubes). The tubes have fins designed to improve the transfer of heat from the refrigerant gas to the air. This removal of heat causes the refrigerant to liquefy, thus liquid refrigerant leaves the coil and flows through a strainer to the capillary tube. The strainer removes any impurities within the refrigerant system. The capillary tube meters the flow of liquid refrigerant to the evaporator coil. As the refrigerant flows through the capillary tube, there is a reduction in pressure and temperature. The evaporator blower (fan) pulls vehicle air through the filters, which remove particulate matter, and then pass the cleaned air through the evaporator coil. The low pressure, low temperature liquid that flows into the evaporator coil tubes is colder than the air that is circulated over the tubes. Heat transfer is established from the vehicle air (flowing over the tubes) to the refrigerant (flowing inside the tubes). The evaporator coil tubes have aluminum fins to increase heat transfer from the air to the refrigerant; therefore the cooler air is circulated to the interior of the vehicle. The transfer of heat from the air to the low temperature liquid refrigerant in the indoor coil causes the liquid to vaporize. This low temperature, low pressure vapor passes into the accumulator. The accumulator is designed with the inlet tube delivering refrigerant to the bottom of the tank and the outlet tube taking refrigerant form the top of the tank. This arrangement ensures that only vapor refrigerant is returned to the compressor, where the cycle repeats. When ventilation only is selected, the indoor fan functions to circulate air throughout the vehicle. The refrigerant cycle will remain off.
1-9
T--298
1.7 REFRIGERANT CYCLE - HEAT PUMP DISCHARGE LIQUID SUCTION INDOOR COIL CAPILLARY TUBE
ACCUMULATOR
Figure 1-9 Refrigerant Flow Schematic - Heat Pump - (Cool Mode) 1.7.1 Cooling The cooling cycle is energized when the thermostat, located in the ceiling unit, calls for cooling The system controls are positioned for normal refrigerant flow, with the compressor discharge delivered to the outdoor coil and liquid delivered to the indoor coil. (See Figure 1-9.) The main components of the system are the compressor, reversing valve, air-cooled outdoor coil, strainer, capillary tube, indoor coil, and the accumulator. The compressor raises the pressure and the temperature of the refrigerant and forces it through the discharge line and reversing valve into the outdoor coil. The outdoor fan circulates surrounding air (which is at a temperature lower than the refrigerant) over the outside of the coil tubes. Heat transfer is established from the refrigerant (inside the tubes) to the outdoor air (flowing over the tubes). The tubes have fins designed to improve the transfer of heat from the refrigerant gas to the air; this removal of heat causes the refrigerant to liquefy, thus liquid refrigerant leaves the coil and flows through the strainer to the capillary tube. The strainer removes any impurities within the refrigerant system. The capillary tube meters the flow of liquid refrigerant to the indoor coil. As the refrigerant flows through the capillary tube, there is a reduction in pressure and temperature. The indoor blower (fan) pulls inside air through the filters, which remove particulate matter, and then pass the cleaned air through the indoor coil. The low pressure, low temperature liquid that flows into the indoor coil tubes is colder than the air that is circulated over the tubes. Heat transfer is established from the indoor air (flowing over the tubes) to the refrigerant (flowing inside the tubes). The indoor coil tubes have aluminum fins to increase heat transfer from the air to the refrigerant; therefore the cooler air is circulated to the interior of the vehicle. The transfer of heat from the air to the low temperature liquid refrigerant in the indoor coil causes the liquid to vaporize. This low temperature, low pressure vapor passes into the accumulator. The accumulator is designed with the inlet tube delivering refrigerant to the bottom of the tank and the outlet tube taking refrigerant form the top of the tank. This arrangement ensures that only vapor refrigerant is returned to the compressor, where the cycle repeats. When ventilation only is selected, the indoor fan functions to circulate air throughout the vehicle. The refrigerant cycle will remain off.
T--298
1-10
CAPILLARY TUBE
ACCUMULATOR
Figure 1-10 Refrigerant Flow Schematic - Heat Pump - (Heat Mode) 1.7.2 Heating The heating cycle is energized when the thermostat, located in the ceiling unit, calls for heat The system controls are positioned for reverse refrigerant flow, with the compressor discharge delivered to the indoor coil and liquid delivered to the outdoor coil. (See Figure 1-10.) The main components of the system are the compressor, reversing valve, indoor coil, capillary tube, strainer, air-cooled outdoor coil, and the accumulator. The compressor raises the pressure and the temperature of the refrigerant and forces it through the discharge line and reversing valve into the indoor coil. The indoor blower (fan) pulls inside air through the filters, which remove particulate matter, and then pass the cleaned air through the indoor coil. The vehicle air (which is at a temperature lower than the refrigerant) passes over the outside of the coil tubes. Heat transfer is established from the refrigerant (inside the tubes) to the vehicle air (flowing over the tubes). The tubes have fins designed to improve the transfer of heat from the refrigerant gas to the air; this removal of heat causes the refrigerant to liquefy, thus liquid refrigerant leaves the coil and flows through the strainer to the outdoor coil. The strainer removes any impurities within the refrigerant system. The capillary tube meters the flow of liquid refrigerant to the outdoor coil. As the refrigerant flows through the capillary tube, there is a reduction in pressure and temperature. The low pressure, low temperature liquid that flows into the outdoor coil tubes is colder than the outdoor air that is circulated over the tubes. Heat transfer is established from the outdoor air (flowing over the tubes) to the refrigerant (flowing inside the tubes). The outdoor coil tubes have aluminum fins to increase heat transfer from the air to the refrigerant. The transfer of heat from the air to the low temperature liquid refrigerant in the outdoor coil causes the liquid to vaporize. This low temperature, low pressure vapor passes into the accumulator. The accumulator is designed with the inlet tube delivering refrigerant to the bottom of the tank and the outlet tube taking refrigerant form the top of the tank. This arrangement ensures that only vapor refrigerant is returned to the compressor, where the cycle repeats. When ventilation only is selected, the indoor fan functions to circulate air throughout the vehicle. The refrigerant cycle will remain off.
1-11
T--298
SECTION 2 TROUBLESHOOTING
For ducted units, the green operation indicator LED (SeeFigure 3-9) will flash if there is a problem. Refer to Table 2- for diagnostic information. -1 SYMPTOM AND PROBABLE CAUSE 2.1 NO POWER TO UNIT 1. Master switch off 2. Open circuit breaker 3. Defective wiring 4. Loose electrical connections 5. Faulty switches, thermostat, or fan 6. 12 VDC not connected (Ducted System) 7. 12 VDC in--line fuse open (Ducted) 2.2 DUCTED UNIT WILL NOT OPERATE 1. Display not illuminated 2. Display illuminated 2.3 DUCTED UNIT WILL NOT COOL 1. Green LED light flashes 5 times PROBABLE REMEDY 1. Reset master switch 2. Reset circuit breaker 3. Replace wiring 4. Tighten connections 5. Replace defective components 6. Connect to 12 VDC power source 7. Replace fuse 1. Check 12 Volt DC in--line fuse 2. Check 115 Volt AC Connections 1. Check 115 volt AC power source Momentarily disconnect 12 VDC power source Disable compressor malfunction test switch. Check AMP draw. Check T 2. Remove grill, verify evaporator coil probe is inserted into coil. Check AMP draw. Check T Replace unit
2.4 COMPRESSOR POWER SUPPLY OPEN 1. Loose leads at compressor terminals 1. Tighten leads 2. Defective motor overload switch 2. Replace switch 3. Defective capacitor 3. Replace capacitor -- Refer to Paragraph 3.5.8 4. Open compressor windings 4. Replace compressor 5. Seized compressor 5. Replace compressor 6. Capacitor incorrectly wired 6. Verify capacitor wiring (Refer to wiring diagram) 2.5 COMPRESSOR RUNS BUT CYCLES, FAN OPERATING ERRATICALLY 1. Loose lead at fan motor 1. Tighten lead. 2. Defective or burned out motor 2. Replace motor. 3. Outdoor air restricted or recirculating 3. Check for dirty condenser coil, proper clearance around unit, remove any obstructions. 4. Overcharge or noncondensables in system 4. Check AMP draw 5. Restricted discharge line 5. Check for obstruction in line. Check T. Replace unit. 6. Defective motor overload switch 6. Replace switch.
2-1
T--298
SYSTEM AND PROBABLE CAUSE 2.6 CYCLES ON COMPRESSOR OVERLOAD 1. Defective run capacitor 2. Defective compressor bearings or valves 3. Greatly restricted evaporator air, iced evaporator coil. 4. Low refrigerant charge 5. Evaporator capillary restricted 6. Liquid line restricted 7. Compressor hot
PROBABLE REMEDY 1. Replace capacitor -- Refer to Paragraph 3.5.8 2. Replace unit. 3. Defrost evaporator coil.
4. Replace unit. 5. Replace unit. 6. Replace unit. 7. Verify refrigerant charge. Check AMP draw. Check T. 8. Weak or inconsistent line power 8. Check line voltage at time of compressor start--up. 2.7 INSUFFICIENT COOLING, COOLING AIR NOT ADEQUATE 1. Dirty evaporator coil 1. Clean as required. 2. Iced evaporator coil, slightly low refrigerant charge 2. Defrost or Recharge. 3. Improper fan operation 3. Verify fan rotation (Refer to wiring diagram) 4. Defective fan motor 4. Replace fan motor. 5. Return air filter is dirty 5. Remove and clean filters (Refer to paragraphs 3.3.1 & 3.4.1) 2.8 CONDENSER AIR NOT ADEQUATE 1. Outside Air Restricted 1. Check for obstruction at coil. Remedy as required. 2. Dirty coil 2. Clean coil. 3. Defective fan motor 3. Replace fan motor. 2.9 INSUFFICIENT COOLING 1. Unit undersized 1. Re--evaluate unit for proper capacity. 2. Capillary restricted 2. Check AMP draw. Check T. Replace unit. 2.10 COMPRESSOR FLOODING 1. Unit overcharged 1. Check AMP draw. Check T. Replace unit. 2. Low evaporator airflow 2. Clean filter and/or evaporator coil. 3. Defective electrical connections 3. Check connections per wiring diagram and tighten any loose connections. 2.11 HEATER CYCLES ON LIMIT SWITCH (HEAT/ COOL VERSION ONLY) 1. Dirty filter 1. Clean or replace filter. 2. Blocked evaporator air inlet (indoor) 2. Remove blockage. 3. Low airflow due to fan motor speed 3. Check fan motor. Repair or replace as necessary. 2.12 AIR SWEEP NOT WORKING (FREE BLOW VERSION ONLY) 1. Ceiling grill not properly aligned 1. Align ceiling grill. 2. Linkage in upper control box stuck 2. Align and lubricate linkage. 3. Air sweep motor failure 3. Replace motor. 2.13 WATER LEAKAGE 1. Water dripping from ceiling unit. 1. Verify vehicle is level Tighten unit mounting bolts evenly or replace unit gasket.
T--298
2-2
PROBABLE REMEDY SYSTEM AND PROBABLE CAUSE 2.14 INADEQUATE HEAT (FREE-BLOW HEAT ONLY) 1. No heat from heat strip. 1. Verify AMP draw . ( 13.8 AMP) Verify resistance through heating element. (9 OHM) Check bi--metal switch. If open, replace switch. 2.15 INADEQUATE HEAT (HEAT-PUMP) NOTE: Allow unit to operate 15 minutes after switching from cooling mode. 1. Reversing valve not operating 1. Check for 115 volts at reversing valve coil Check for reversing valve restriction Verify compressor operation 2. Check outdoor coil sensor
2-3
T--298
Table 2- System Self-1 -diagnostics Function (Ducted Remote) Flashes Error Codes Error Contents Display Pattern
0.5 sec. (Twice)
(Priority) 2
1
(Malfunction)
ROOM AIR THERMISTOR FAILURE
3sec .
3sec .
3sec.
3sec.
3sec .
3sec .
3sec .
3sec .
Continuous
FAN Mode
3sec .
NOTE: If more than two errors occur, the highest ranked code is displayed. If the highest ranked error is cleared, the next highest ranked error code is displayed. T--298 2-4
WARNING
Before working on the unit be sure to first disconnect all electric power to the unit to avoid the possibility of electrical shock and personal injury. Before disconnecting, discharge capacitors by shorting across the capacitors terminals (Refer to paragraph 3.5.8)
WARNING
Shield coils with cardboard to protect hands against injury from sharp metal edges when removing compressor and other components. 3.3 CEILING UNIT - FREE BLOW SYSTEMS 3.3.1 Filter Removal The filters (Figure 3-1) are located in the ceiling grill. To remove the filters, do the following: a. Grasp the edge of the filter at recess in the end of the ceiling grill. b. Pull filter completely out of the filter slot. c. Vacuum filter or wash filter in luke--warm water. Shake off excess water and dry thoroughly. d. Replace filter by sliding the filter into the filter slot in the ceiling grill until the filter frame is flush with the interior grill. Filters
CAUTION
Do not use carbon tetrachloride, solvents, or waxes containing solvents to clean plastic sections. Painting--Paint any parts that show evidence of rust with a good rust--prevention paint. Wiring- Check all wiring for deterioration and all electrical contacts for tightness or corrosion. Mounting--Make sure unit is secure on roof according to installation instructions provided in Owners Guide. Check fans to insure that they are correctly positioned in the center of the orifice, and tight on the shaft. Leaks--Check any connections that show evidence of oil or leaks. When unit is properly installed (refer to Owners Guide) check gaskets for possible air leakage. Controls--Check unit to ensure all controls are functioning correctly and unit operation is normal. Vibrations can cause unwanted noise. NOTE Check to ensure that piping is not vibrating against side of the unit. NOTE For proper cleaning and flushing, use a UL approved refrigerant recovery/recycling system. NOTE Refrigerant removal must always include recovering the refrigerant, not allowing it to escape to the atmosphere. 3.2 SERVICE - GENERAL General NotesThese Service Instructions are provided to assist the trained and qualified Carrier service technician in repairing or replacing components of the AirV units. 3-1
Figure 3-1 Filter Removal - Free Blow 3.3.2 Ceiling Grill Removal To remove the ceiling grill (Figure 3-2) do the following: a. Before working on unit place the master switch in the OFF position and disconnect all electrical power. b. Remove 4 screws located on the ceiling grill, making sure to support the weight of the grill. c. Lower the ceiling grill from the ceiling panel. T--298
d. To replace the grill, place the grill up against the ceiling panel and align the screw holes in the grill with the ceiling panel. e. Replace 4 screws.
Heater Assembly Option Mounting Screws Figure 3-4 Ceiling Panel With Heat Option 3.3.4 Master Control Switch To remove the master control switch, do the following: a. Remove ceiling grill. (Refer to paragraph 3.3.2.) b. Remove 5 screws that secure the control assembly (Item 2, Figure 1-3) to the control box cover. c. Remove the master control switch knob by grabbing the outside edge of the knob and pulling it off of the switch stem. d. Remove 2 screws securing the master control switch to the control assembly. e. Carefully disconnect wires from the master control switch. Label wires to aid in reassembly. f. Reverse above procedure for reassembly. Junction Box With Cover Air Sweep Switch
Figure 3-2 Ceiling Grill - Free Blow 3.3.3 Ceiling Panel Removal To remove the ceiling panel (Figure 3-3) do the following: a. Remove the ceiling grill. (Refer to paragraph 3.3.2.) b. Remove 5 screws securing the duct plate to the ceiling panel. c. Remove 4 mounting bolts making sure to support the weight of the ceiling panel. d. Disconnect the unit harnesses and main power wires from the ceiling panel. e. Lower the ceiling panel from the air conditioning unit. f. Reverse above procedure for reassembly.
Air Sweep Cam Serial/Model Number Tag Duct Plate & Mounting Holes
Thermostat
Figure 3-5 Control Box Assembly - Free Blow 3.3.5 Air Sweep Switch Removal To remove the air sweep switch, do the following: a. Remove ceiling grill. (Refer to paragraph 3.3.2.) b. Remove 5 screws securing the control assembly (Item 2, Figure 1-3) to the control box cover. c. Disconnect wires from the air sweep switch. d. Pinch tabs on either end of the switch and slide out of lower control box cover. e. Reverse above procedure for reassembly.
T--298
3-2
3.3.6 Indoor Thermostat Removal To remove the indoor thermostat (Figure 3-6) do the following: a. Remove ceiling grille. (Refer to paragraph 3.3.2.) b. Remove 5 screws securing the control assembly (item 3, Figure 1-3) to the control box cover. c. Remove the indoor thermostat knob by grabbing the outside edge of the knob and pulling it off of the thermostat stem. d.Remove 2 screws that secure the indoor thermostat to the lower control box cover. e. Carefully disconnect the 2 wires from the indoor thermostat. f. Remove the sensing bulb from the plastic clip. g. Carefully slide the sensing bulb through the rubber grommet. h. Remove the thermostat from the control assembly. i. Reverse above procedure for reassembly. Thermostat Air Sweep Motor
Figure 3-7 Air sweep motor 3.3.8 Heat Strip Assembly Removal To remove the heat strip assembly (Figure 3-8) do the following: a. Remove ceiling grille. (Refer to paragraph 3.3.2.) b. Unplug electrical connection at air sweep motor assembly. c. Remove two screws securing heat strip assembly to the ceiling panel assembly. d. Slide heat strip assembly away from air sweep motor assembly and pull down, easing the the electrical connection through the access hole. e. Reverse the procedures for reassembly.
Sensing Bulb Figure 3-6 Indoor Thermostat 3.3.7 Air Sweep Removal To remove the air sweep, do the following: a. Remove ceiling grille. (Refer to paragraph 3.3.2.) b. Remove cam (See Figure 3-3) from air sweep motor shaft. c. Remove 4 screws securing air sweep motor bracket to the ceiling panel assembly. d. Carefully disconnect air sweep motor wire terminations. e. Remove 2 screws securing air sweep motor (Figure 3-7) to control box and remove motor. f. Reverse above procedure for reassembly.
Heat Strip
3-3
T--298
3.4 CEILING UNIT - DUCTED SYSTEMS 3.4.1 Filter Removal The filters (Figure 3-9) are located in the ceiling grill. To remove the filters, do the following: a. Grasp the edge of the filter at recess in the end of the ceiling grill. b. Pull filter completely out of the filter slot. c. Vacuum filter or wash filter in luke--warm water. Shake off excess water and dry thoroughly. d. Replace filter by sliding the filter into the filter slot in the ceiling grill until the filter frame is flush with the interior grill.
c. Remove two screws securing control box cover to control box assembly. See Figure 3-11. d. Remove control box assembly cover.
Mounting Screws
Filters
Figure 3-10 Ceiling Grill - Ducted e. Disconnect blue furnace wires. f. Unplug two connectors from upper unit. g. Unplug DC power plug #1 (red/yellow/black wires) See Figure 3-12
Operation Indicators
h. Unplug relay signal plug #2 (brown/red/orange/ yellow wires). See Figure 3-12 i. While supporting control box assembly remove two screws securing control box assembly to ducted ceiling unit. j. Pull control box assembly from the ducted ceiling unit. k. Reverse above procedure to reassemble.
Figure 3-9 Filter Removal - Ducted Unit 3.4.2 Ceiling Grill Removal To remove the ceiling grill (Figure 3--10) do the following: a. Before working on unit place the master switch in the OFF position and disconnect all electrical power. b. Remove filters (Refer to paragraph 3.4.1). c. Remove 4 screws located on the ceiling grill, (two are under the filters) making sure to support the weight of the grill. d. Lower the ceiling grill from the ceiling panel. e. To replace the grill, place the grill up against the ceiling panel and align the screw holes in the grill with the ceiling panel. f. Replace 4 screws and 2 filters. 3.4.3 Control Box Assembly Removal To remove the control box assembly (Figure 3-11 & Figure 3-12) do the following: a. Remove ceiling grill. Refer to paragraph 3.4.2. b. Disconnect 115 volt (AC) and 12 volt (DC) power wires. T--298 3-4
115V AC 12V DC
3.4.5 PCB Display Removal To remove the PCB display assembly (Figure 3-13) do the following. a. Remove ceiling grill. Refer to paragraph 3.4.2. b. Push large clip away from PCB display assembly.
Fuse
#1
c. Push center clip towards large clip. d. Pull PCB display assembly from PCB cover. e. Unplug display wiring from PCB main assembly.
#2
f. Reverse above procedures of reassembly. 3.4.6 Fuse Removal To remove the fuse (Figure 3-11) do the following:
Figure 3-12 Control Box Assembly - Ducted 3.4.4 Main PCB Board Removal To remove the Main PCB board (Figure 3-13) do the following: a. Remove ceiling grill. Refer to paragraph 3.4.2. b. Remove three screws securing the PCB cover to the ducted ceiling unit. c. Carefully turn over the PCB cover exposing the PCB main and the PCB display assemblies. d. Gently push holding clip away from PCB main assembly. e. Lift PCB main assembly from PCB cover assembly. f. Unplug display wiring plug #4. Figure 3-13 g. Unplug thermistor/thermostat Figure 3-13 wiring plug #3.
a. Remove ceiling grill. Refer to paragraph 3.4.2. b. Turn fuse holder in direction of arrow (counter-- clock-wise). c. Pull fuse from fuse holder. d. Test and/or replace. e. Reverse above procedures for reassembly. 3.5 SERVICE - UPPER UNIT - STANDARD, HC & HP 3.5.1 Exterior Cover Removal
CAUTION
Coil fins are sharp. Use care when removing the cover form the base pan to avoid personal injury. To remove the exterior cover, do the following: a. Before working on unit place the master switch in the OFF position and disconnect all electrical power.
h. Unplug power wiring plug #1. Figure 3-12 i. Unplug signal wiring plug #2. Figure 3-12 j. Reverse above procedures for reassembly.
b. Remove 15 screws securing the unit cover to the base pan assembly. See Figure 3-14. c. Carefully lift the exterior cover off of the unit base pan assembly. d. Reverse above procedure for reassembly.
PCB Main
#4
3.5.2 Compressor Replacement Observe the same procedures for rotary compressors as for reciprocating compressors. a. Follow all safety codes. Reminder: use protective goggles, work gloves, and water soaked quenching cloth. b. Remove exterior cover. refer to paragraph 3.5.1. Disconnect all wiring from the compressor. c. Apply field--supplied, line--tap--valves to the suction and discharge lines as close to the compressor as possible. d. Recover the refrigerant charge from the unit. After recovering, cut the discharge and suction line process tubes below the tube crimps. If you choose a good tubing location for cutting the refrigeration lines initially, the location is easily accessible when making the final joints.
WARNING
Oil vapor in piping stubs can ignite from torch flame and cause serious injury. Exercise extreme care when brazing, and keep brazing cloth and fire extinguisher handy for emergency use. e. Connect a nitrogen supply to the unit at one of the line --tap--valve connectors (5--psig maximum flow), leaving the other connector open to the atmosphere. Braze angle valves with stubs to each process tube. f. Remove compressor from unit (3 bolts). g. Remove line--tap--valves from suction and discharge lines. Carefully braze the holes closed from where the line--tap--valves were removed. h. Clean system: add or replace liquid line filter drier. For proper cleaning and flushing use a UL approved refrigerant recycling system. i. Install new compressor and braze into place with field--supplied copper slip couplings. j.Connect wiring: replace wire terminals if necessary. k. Proceed with evacuation and charging (15.9 OZ. -.45 KG R22). Pinch off lines where angle valves were added. Cut off angle valves above pinch--off , and braze tubes. l. Start up unit. 3.5.3 Control Box Assembly Removal To remove the control box assembly, do the following: a. Remove exterior cover assembly. Refer to paragraph 3.5.1. b. Remove 2 screws securing control box assembly to the lower scroll assembly. (SeeFigure 3-15.)
Water Cover
Figure 3-16 Control Box Removal c. Slide control box out of the lower scroll assembly. (See Figure 3-16.) d. To open control box remove 2 screws securing the water cover to the control box cover. e. Gently lift the water cover off of the control box. (See Figure 3-17.) f. Reverse above procedure for reassembly.
T--298
3-6
3.5.4 Upper Scroll Assembly Removal a. Remove exterior cover assembly. Refer to paragraph 3.5.1. b. Remove 4 screws securing upper scroll assembly to the lower scroll assembly. (See Figure 3-18) c. Gently pry 4 snap clips open and lift the upper scroll assembly off of the lower scroll assembly. d. Reverse above procedure for reassembly. Screws 4 Places
i. Remove condenser fan from motor shaft and lift fan out through the top of the condenser orifice. (See Figure 3-22) j. Remove motor assembly. k.Reverse above procedure for reassembly.
Figure 3-18 Upper Scroll Assembly 3.5.5 Motor Assembly and Condenser Fan Removal a. Remove exterior cover assembly. Refer to paragraph 3.5.1. b. Remove control box assembly. Refer to paragraph 3.5.3. c. Remove upper scroll assembly. Refer to paragraph 3.5.4. d. Remove 4 screws securing the condenser cover to the condenser orifice. (See Figure 3-24.) e. Carefully disconnect motor wire terminations from within the control box. f. Remove 1 screw securing the motor ground lead to the motor bracket assembly. (See Figure 3-19) g. Using flat--nosed pliers, depress the motor spring clamp and slide it off of the condenser fan (See Figure 3-20). h. Lift and slide motor towards evaporator coil to remove condenser fan from the motor shaft. 3-7
Motor Clip
Motor Assembly
Base Pan Base Pan Figure 3-24 Condenser With Motor Assembly & Compressor
T--298
3-8
WARNING
Do not touch the metal of the screwdriver when discharging the capacitor. You could receive a shock. b. After the capacitor has been discharged and all wires removed from the capacitor terminals, use an ohm-meter to test its resistance. c. Set the scale to R x 1K or 10K ohm and place the ohmmeter leads across the capacitor terminals. d. If the ohmmeter first reads 0, then rises toward infinity or some higher resistance, the capacitor is good. e. If the ohmmeter goes to 0 or a low resistance and stays there, the capacitor is shorted and needs to be replaced. f. If the ohmmeter reads infinity (OL) the capacitor is open and needs to be replaced.
WARNING
Disconnect power to the AirV unit before checking the capacitor. To test capacitor to determine if good, open or shorted, an ohm meter can be used. To determine a capacitors capacitance, a capacitor meter is required. Capacitors showing signs of leaks or bulging should be replaced immediately.
ATTACH TO CLEAN UNPAINTED METAL PART OF UNIT FRAME CLIP TO SCREWDRIVER TOUCH TO CAPACITOR TERMINALS TO DISCHARGE CAPACITOR
Figure 3-25 Set-Up For Discharging a Capacitor 3.5.10 Positive Temperature Coefficient Thermister (PTC) (Start Thermistor) Troubleshooting a. Disconnect power from the AirV unit. b. Disconnect the wires to the PTC. c. Using an ohm meter, check for continuity across the PTC. If the PTC does not have continuity, it must be replaced. If continuity exists, reconnect the wires to the PTC. d. Reconnect power to the AirV unit. e. Turn on the AirV unit to start. f. Use a clamp--on amp probe to monitor the amp draw of the compressor during its start--up. When the compressor starts, an amp draw will be indicated for almost a second. If no amp draw is indicated or if the amp draw occurs for much longer than a second, the PTC is defective and must be replaced. 3.5.11 Line Voltage - 10% Line voltage should be checked during peak electrical load periods. With the AirV unit on and the compressor operating, use a voltmeter to check the voltage being supplied to the AirV unit. The voltage must be within 10% of the units required voltage. A voltage drop greater than 10% will cause a premature compressor failure and needs to be corrected immediately.
3-9
T--298
3.6 SERVICE - UPPER UNIT - LOW PROFILE 3.6.1 Exterior Cover Removal b. b.
CAUTION
Coil fins are sharp. Use care when removing the cover form the base pan to avoid personal injury. To remove the exterior cover, do the following: a. Before working on unit place the master switch in the OFF position and disconnect all electrical power. b. Remove (8) screws securing the unit cover to the base pan assembly. See Figure 3-26. c. Carefully lift the exterior cover off of the unit base pan assembly. d. Reverse above procedure for reassembly. b. b.
c. b. b.
Figure 3-27 Upper Scroll Assembly Locking Tabs (b.) & Screw Locations (c.)
Screws Screws
Figure 3-26 Cover Assembly - Low Profile 3.6.2 Upper Scroll Assembly Removal To remove the upper scroll assembly, do the following: a. Remove exterior cover assembly. Refer to paragraph 3.6.1. b. Release the (2) front, (2) rear, (1) left side and (1) right side locking tabs (See Figure 3-27) by pulling back on the tabs (See Figure 3-28). c. Remove the screw (1) from the control box cover (See Figure 3-27). d. With all (6) locking tabs released and control box screw removed, lift the upper scroll assembly off of the lower scroll assembly. e. Reverse above procedure for reassembly. Ensure all (6) locking tabs snap shut & lock.
T--298
3-10
Evaporator Coil
Retaining Ring
Fan Stop Condenser Coil 13MM Bolt Condenser Motor 13MM Bolt
Grommet Figure 3-29 Upper Scroll & Control Box Cover Removed 3.6.3 Condenser Fan Assembly Removal To remove condenser fan assembly, do the following: a. Perform steps outlined in Section 3.6.2. b. Depress and Figure 3-30). remove Retaining Ring (See Tab
c. Using both hands, carefully pull up on fan assembly until it is free of the motor shaft. d. When replacing the fan assembly make sure the fan assembly is against the stop on the shaft (See Figure 3-31) e. Push back on tab to allow fan assembly to rest against stop (See Figure 3-32). Fan assembly will now be flush with the end of the motor shaft. f. Reverse above procedure for reassembly. 3-11 Figure 3-32 Condenser Fan Motor & Fan Assembly Tab T--298
3.6.4 Condenser Motor Removal To remove condenser fan motor, do the following: a. Perform steps outlined in Section 3.6.2. b. Remove (3) 13MM bolts (See Figure 3-31). c. Remove (3) Grommets. Inspect, replace or reuse. d. Cut Tie--Wraps & discard (2 locations). When reassembling, tie--wrap at same 2 locations. e. Remove ground wire from compressor bracket (See Figure 3-33). f. Un--plug (yellow/brown/white) from control box assembly. g. Reverse above procedure for reassembly.
Figure 3-33 Condenser Motor Ground 3.6.5 Evaporator Motor/Blower Assembly Removal To remove the evaporator motor, do the following: a. Perform steps outlined in Section 3.6.2. b. Pull back on and release the (4) locking tabs. There are 2 on each side of the control box assembly. (See Figure 3-34). c. Lift control box assembly from lower scroll assembly, exposing evaporator motor. d. Un--plug (black/blue/white/brown) evaporator motor from control box assembly. e. Remove ground wire (green/yellow) from motor housing. f. Lift motor/blower assembly from lower scroll assembly cradle. g. Carefully remove the blower wheel from the evaporator motor shaft by pushing out from the motor side.
Capacitor
T--298
3-12
NOTE When reassembling the blower wheel on to the motor shaft ensure that the blower wheel is flush with the end of the motor shaft (SeeFigure 3-36). h. Reverse above procedure for reassembly.
NOTE When placing the evaporator motor/blower assembly back into the lower scroll assembly cradle, make sure that the assembly is seated securely in the cradle. (See Figure 3-35).
3.6.6 Compressor Replacement Perform the procedures outlined in Section 3.5.2 There are 4 bolts with the Low Profile Compressor. The system charge for the Low Profile unit is 16.9 OZ. 3.6.7 Capacitor Removal To remove the capacitor, do the following: Wheel Flush With Motor Shaft a. Perform steps a., b. & c. as outlined in Section 3.6.5. b. Perform steps outlined in Sections 3.5.8 & 3.5.9. Figure 3-36 Evaporator Blower Wheel (Flush With End Of Motor Shaft) c. The Low Profile Capacitor is removed from the control box assembly by pushing on the capacitor from under the control box assembly (See Figure 3-35).
Capacitor
Terminal Block
Figure 3-37 Control Box Assembly With Capacitor 3.6.8 Remote Control (Fahrenheit to Celsius) All Remote Control Assemblies in the United States are pre--set to display in Fahrenheit degrees (see Figure 3-38). To change from a Fahrenheit display to a Celsius display do the following: 3-13
CAUTION
The change from Fahrenheit to Celsius will be permanent. It cannot be changed back to Fahrenheit. T--298
a. Remove the batteries from the remote control. b. Carefully remove the remote cover by inserting a narrow flat object between the cover and remote body and prying apart. c. Remove the brass screw holding the PCB in place. d. Carefully remove the PCB board from the remote body, making sure the battery springs release from their holders. e. Locate FR9 on the PCB board (see Figure 3-39).
f. Carefully cut the FR9 jumper wire. g. Reverse above procedure for reassembly.
CAUTION
When re-assembling, ensure the battery springs are correctly placed in the battery spring holders. Battery Springs Spring Holders
PCB
BODY
PCB
FR9
T--298
3-14
3.7 THERMOSTAT INSTALLATION AND STARTUP INSTRUCTIONS (WALL MOUNTED) 3.7.1 Introduction The thermostat is a wall mounted, low--voltage thermostat which maintains room temperature by controlling the operation of a heating and air conditioning system. Batteries are not required; temperature and mode settings are preserved with the power off.
2.Disconnect wires from existing thermostat, one at a time. Be careful not to allow wires to fall back into the wall. 3.As each wire is disconnected, record wire color and terminal marking. 4.Discard or recycle old thermostat. NOTE Mercury is a hazardous waste and must be desposed of properly. c. Seperate the front and back pieces of plastic. d. Route thermostat wires through hole in back piece of plastic. Level plastic against wall (for aesthetic value only -- thermostat need not be leveled for proper operation) and mark wall through 2 mounting holes. e. Drill two 3/16 inch mounting holes in wall where marked. NOTE Mounting holes on thermostat are designed to fit on a horizontal J--Box. f. Secure back plastic to wall with 2 anchors and screws provided, making sure all wires extend through hole in plastic. g. Connect wires to proper terminal of the connector block in the front piece of plastic. h. Pusr any excess wire back into wall. Excess wire inside the thermostat plastic case can interfere with proper air flow across the temperature sensor. Seal hole in wall to prevent air leaks. Leaks can effect operation. i. Snap front and back pieces of plastic together. j. Turn on power to the unit. 3.8 LCD DISPLAY 3.8.1 Cool Only Thermostat (Part No. 1110-421) On power up, the LCD readout will display C (Cool Only). 3.8.2 Heat/Cool Thermostat (Part No. 1110-420) On power up, the LCD readout will display HC (Heat/ Cool). 3.9 SET THERMOSTAT CONFIGURATION While in configuration mode, three option choices can be made. A - Anticipator Value Adjustment d - Display Temperature Fahrenheit/Celcius Selection oF - Offset Adjustment For Room Temperature 3.9.1 Enter Configuration Mode Enter and hold the FAN button for approximately 10 seconds until room temperature disappears and the display reads A. You are now in the configuration mode. 3-15 T--298
CAUTION
Improper wiring or installation may damage thermostat. Wiring must conform to local and national electrical codes.
WARNING
Before installing thermostat, turn off all power to unit. There may be more than one power disconnect. Electrical shock can cause personal injury or death. 3.7.2 Installation NOTE Read all instructions before starting the installation. NOTE The thermostat requires no batteries. The thermostat is not a power stealing device and MUST have both R and C connected. 3.7.3 Thermostat Location The thermostat should be mounted: Approximately 5 foot (1.5m) from the floor. Close to or in a frequently used room, preferably on an inside partitioning wall. On a section of wall without pipes or duct work. The thermostat should NOT be mounted: Close to a window, or an outside wall, or next to a door leading to the outside. Exposed to direct light and heat from a lamp, sun, fireplace, or other temperature--radiating object which may cause a false reading. Close to or in direct airflow from supply registers and return--air grilles. In areas with poor air circulation, such as behind a door or in an alcove. 3.7.4 Install Thermostat - 12VDC a. Turn off all power to unit. b. If an existing thermostat is being replaced: 1.Remove existing thermostat from wall.
NOTE If the FAN button is pressed again or if no button is pressed for two minutes, the thermostat will exit the configuration mode and return to normal operation. To re--enter the configuration mode, the FAN button must be pressed and held for 10 seconds again. While in the configuration mode, the following options are available: A. ANTICIPATOR - Value Adjustment This adjustment controls the sensitivity and cycle rate of the thermostst. Higher numbers decrease the sensitivity and slow the cycle rate. Lower numbers increase the sensitivity and increase the cycle rate. However, a limiting feature will not allow more than 4 equipment cycles per hour, regardless of setting. Values can range from 1 to 3. Factory default setting is 2. This default selection will provide optimum performance in nearly all installations. Try it first. Do not change settings unless there is evidence of need to do so. Unlike conventional anticipators, this setting is not determined by current draw. There is no need to measure, know, or compensate for current. To Adjust: a. Enter configuration mode (if not already there). b. Use UP & DOWN buttons to display A. c. Press MODE button once to display current value. d. Use UP & DOWN buttons to move between values. e. Press MODE buttonto return to A. UP & DOWN buttons now move between option choices A, d, oF or press FAN button to exit configuration mode. d. Fahrenheit/Celsius Selection This selection operates the thermostat in either Fahrenheit or Celsius. To Select: a. Enter configuration mode (if not already there). b. Use UP & DOWN buttons to display d. c. Press MODE button once to display current selection of F or C. d. Use UP & DOWN buttons to change between F & C. e. Press MODE buttonto return to d. UP & DOWN buttons now move between option choices; or press FAN button to exit configuration mode. oF. Room Temperature Offset Adjust Selection The selected number is the number of degrees, plus or minus, which will be added to the actual temperature. The numbers can range between --5 and +5. Factory default is 0. This adjusted value will be used as actual temperature for both display and control action. The effect is that a positive number selection will make the room temperature lower, and vice versa. The thermostat is calibrated within an accuracy of plus or minus 2 degrees when shipped from the factory; this adjustment will provide the best accuracy when set to o. To Select: a. Enter configuration mode (if not already there). b. Use UP & DOWN buttons to display oF . T--298 3-16
c.
d. Use UP & DOWN buttons to select a value between --5 and 5. e. Press MODE buttonto return to oF. UP & DOWN buttons now move between option choices; or press FAN button to exit configuration mode. 3.10 CHECK THERMOSTAT OPERATION 3.10.1 Fan Operation (Cool Only) 1. Press FAN button, starting fan operation. FAN annunciator turns on; Lo is displayed in the room temperature area for 5 seconds indicating Fan Low Speed. 2. Press FAN button, FAN annunciator remains on; Hi is displayed in room temperature area for 5 seconds indicating Fan High Speed. 3. Press FAN button, stopping fan operation. FAN annunciator turns off. 3.10.2 Fan Operation (Heat/Cool) 1. Press FAN button, starting low fan (Lo) operation. FAN annunciator turns on. 2. Press FAN button, starting high fan (Hi) operation. FAN annunciator remains on. 3. Press FAN button, stopping fan operation. FAN annunciator turns off. 3.10.3 Cooling Operation (Cool Only) 1. Press and release MODE button until COOL is displayed. 2. Press DOWN button until LCD readout reads 10 degrees below room temperature. Cooling and High Fan system should begin to operate within 5 minutes. 3.10.4 Cooling Operation (Heat/Cool) 1. Press and release MODE button until COOL is displayed. 2. Press DOWN button until LCD readout reads 10 degrees below room temperature. Cooling and High Fan system should begin to operate within 5 minutes. 3.10.5 Heating Operation (Heat/Cool) 1. Press and release MODE button until HEAT is displayed. 2. Press UP button until LCD readout reads 10 degrees above room temperature. Heating system should begin to operate within 1 minute. 3.11 CHECK THERMOSTAT OPERATION 3.11.1 Temperature Display The thermostat will display room temperature until the UP or DOWN button is pressed. The word SET appears when these buttons are pressed and the current set point is displayed. If no buttons are pressed for 5 seconds, the display will change back to show room temperature.
3.11.2 Timeguard Timer A 3--minute timeguard is built into the thermostat immediately upon power up, and any time the compressor (output Y) turns off. The compressor will not turn on until the timeguard has expired. Pressing UP and FAN buttons simultaneously will override the timeguard for 1 cycle. 3.11.3 Cycle Timer In normal cooling (and heating) operation the thermostat will not allow more than 4 equipment cycles per hour (or 1 cycle every 15 minutes). Both the Y (cooling) and W (heating) outputs have a 15--minute timer that starts counting down when the output is turned on, (e.g., if Y output is turned on for 9 minutes and then satisfies, it cannout turn back on for another 6
minutes regardless of demand). However, pressing UP and FAN buttons simultaneously or changing the set point will override the timer for 1 cycle. 3.11.4 Minimum On Timer Once the equipment has turned on, it will remain on for a minimum of 2 minutes regardless of demand. However, the equipment can turn off in less than 2 minutes if a change in set point, or a changein mode occurs. 3.11.5 Error Messages E4 will be displayed if the thermostat has an internal memory failure. If E4 appears, replace the thermostat. ---- (two dashes) will be displayed if the thermostat cannot properly read the room temperature. If ---appears, replace the thermostat.
UPPER UNIT
Factory Wiring
Field Wiring
Motor
Comp.
1 2 3 4
1 2 3 4
CEILING UNIT
Figure 3-40 Wall Thermostat Wiring Diagram - Cool Only Model 3-17 T--298
Field Wiring
Motor
Comp.
1 2 3 4
21
1 2 3 4
1 2
Blue Blue
+ 12VDC 12 VDC (Gnd)
CEILING UNIT
FURNACE
T--298
3-18
4P
1 2 PLUG CONNECTS TO CEILING UNIT SEE FIG> 4-3 OR 4-4 3 4 GRN/YEL GRN/YEL BLK BLU
2P
1 2 BLK BLU
BRN WHT
GRN/YEL WHT F C H
CAPACITOR
2P
1 2
CONTROL BOX
EVAP. WHT
RED RED
R
BLU
YEL
1 2
YEL
C S OVERLOAD PROTECTOR (If Used) COMPRESSOR
PTC BLU
Figure 4- Upper Unit Schematic - Standard & HC -1 (UNIT - 99- 00468- 10) INDOOR FAN MOTOR
BLK BLU WHT BRN GRN/YEL
PLUG CONNECTS TO CEILING UNIT. SEE DIAGRAM SUPPLIED WITH CEILING UNIT FOR ADDITIONAL WIRING.
4P
1 2 3 4 BLK BLU WHT GRN/YEL FMC YEL WHT BRN 1 2 3 4
4P
1 2 3 4
3P
1 2 1 2 3 BRN WHT WHT YEL WHT BRN
2P
1 2
WHT YEL
F H
CAPACITOR
BLU
RED
LEGEND
OLP: OVERLOAD PROTECTION PTC: START THERMISTER JTB: JOINT TERMINAL BLOCK FMC: INDOOR FAN MOTOR CAPACITOR
YEL
COMPRESSOR
BLK
4
4P
BLU
2
SWITCH POSITION HIGH FAN LOW FAN OFF LOW COOL HIGH COOL O (OFF) ASW I (ON)
CONTACTS MADE 1--4 . 1--6 1--2 . 1--6 NONE 1--2 . 1--6 . 1--8 1--4 . 1--6 . 1--8 2 2 -- 1
ASW
1 6
2 ORN WHT
1 2
ORN
2
3 4
BLK YEL
8 C L
2P
GRN/YEL
ORN
WHT
SW
WHT GRN/YEL
IT
ASM 2P
1 YEL 2
LEGEND
ASM : AIR SWEEP MOTOR ASW : AIR SWEEP SWITCH SW : SWITCH IT : INDOOR THERMOSTAT
4P
1 BLU 2
CONTACTS MADE NONE L1--L . L1--A L1--H . L1--A L2--C . L1--L . L1--A . B--3 L2--C . L1--H . L1--A . B--3 L2--HT . L1--L . L1--A . B--1
2
L L1
YEL
1 B 3
IT
2
ASW HEATER-ASSY
BLK
ORN
ORN
WHT
2P
ORN
RED BLU
WHT GRN/YEL
BLK
ASM
ASW
2 -- 1
HT
BLK WHT
2 1
BLK BT WHT
HEATER
LEGEND
WIRING. ASM AIR SWEEP MOTOR ASW AIR SWEEP SWITCH SW SWITCH IT INDOOR THERMOSTAT CEC CLOSED END CONNECTOR BT BIMETAL
L2
2P
{
LEGEND
2P
WHT 1 2 YEL
WHT GRN/YEL
CEC
1 2 3 4
BLK
WHT
CN3
IDC Th
BRN
1 2 3 4
CN4
RY1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
RY3
RY2
L N2 N1
BLK WHT
GRN/YEL
1 2 3 CN9 1 2 3 4 5 6 7 8 CN9 1 2 3 4 5 6 7 8
1 2 3
1 2 3
CN2 1 2
2 1 CN1
RED BLK
(+) (--)
12 VDC POWER
BLU BLU
DISPLAY PCB AS
PLUG CONNECTS TO CEILING UNIT. SEE DIAGRAM SUPPLIED WITH CEILING UNIT FOR ADDITIONAL WIRING.
FAN MOTOR
4P 1 2 3 4 BLK BLU WHT GRN/YEL GRN/YEL 4P 1 2 3 4 1 2 3 4 BLK BLU WHT BRN
OLP: OVERLOAD PROTECTION PTC: START THERMISTER RVC: REVERSING VALVE COIL
GRN/YEL
BRN
WHT
F H
CAPACITOR
BLU
RED
PTC
FREEZE SWITCH
COMPRESSOR
SW H L L1 A BLK HT HEATER AS L2 C HEATER BT 2P BLK WHT 1 B BLK 3 YEL RED H 1 3 L IT C 2 WHT 2 1 2 1 BRN ASM ORN 2 ASW BLK BLK BLU 1 ORN 2P ORN 1 2 1 2 WHT GRN/YEL WHT
4P 1 2 WIRING. UPPER UNIT FOR ADDITIONAL 3 4 PLUG CONNECTS TO UPPER UNIT. SWITCH POSITION
OFF LOW FAN HIGH FAN LOW COOL HIGH COOL HEATING
CONTACTS MADE
NONE L1--L . L1--A L1--H . L1--A L2--C . L1--L . L1--A . B--3 L2--C . L1--H . L1--A . B--3 L2--HT . L1--L . L1--A . B--1
2P 1 2
2 2- 1 -
WHT
GRN/YEL
4-3
T--298
LEGEND
CN :HOUSING CONNECTOR FAN MOTOR
BLK BLU RED 3 WHT BRN 6 GRN/YEL
PTC :START THERMISTOR OLP :OVERLOAD PROTECTOR RVC :REVERSING VALVE COIL ODA Th :OUTDOOR AIR THERMISTOR ODC Th :OUTDOOR COIL THERMISTOR
1 BLU 2
1 2 RED
3 GRN/YEL 4
BRN F C H
CAPACITOR
WIRING.
COMPRESSOR
OLP RED R 2 (3) YEL C S BLU (IF USED) BLK(BLU) RVC 1
RED
BLU
1 2
PTC
CN
LEGEND
IDC Th: INDOOR COIL THERMISTER RA Th: ROOM AIR THERMISTER ODC Th: OUTDOOR COIL THERMISTER ODA Th :OUTDOOR AIR THERMISTOR RVC: REVERSING VALVE COIL D1: DIODE K: RELAY
CN5 1 2 3 RA Th BLK CN1 1 2 3 4 IDC Th BRN 1 2 3 4 5 6 7 8 CN4 1 2 3 CN9 CN9 1 2 3 4 5 6 7 8 CN6 1 2 3 CN6 1 2 3 4 5 6 7 8 CN4 1 2 3 1 2 3 4 5 6 7 8 BLK BRN ODC ODA RVC 1 2 RED WHT
PLUG CONNECTS TO UPPER UNIT. SEE DIAGRAM SUPPLIED WITH UPPER UNIT FOR ADDITIONAL WIRING.
MOTOR 1 2 3 4 BLK 1 2 CN5 BLU BLK RED GRN/YEL BLK Y COMPRESSOR 2 1 WHT * * * 1 2 3
NOTE
FACTORY WIRING FIELD WIRING (115VAC HIGH VOLT.) FIELD WIRING (12VDC LOW VOLT.)
1 2 3 4 CN3
BLK K7 K2 K3 K4 K1 L N2 N1
115VAC POWER
WHT GRN/YEL
1 2 3 4 5 6 7 8
BLU
DISPLAY PCB AS
T--298
4-4
Figure 4-10 Ceiling Unit - Wall Thermostat - Ducted & Free Blow -
4.2 WALL MOUNTED THERMOSTATS For proper wiring of Wall Mounted Thermostats as an accessory, refer to Figure 3-40 (Wall Thermostat Wiring Diagram -- Cool Only Model) or Figure 3-41 (Wall Thermostat Wiring Diagram -- Heat/Cool Model).
4-5
T--298
INDEX
A
Air Handling System , 3-8 Air Sweep Removal, 3-3 Air Sweep Switch , 3-2
I
Indoor Thermostat , 3-3 INTRODUCTION, 1-1, 4-1
L C
Capacitor Testing, 3-9 Capacitor Testing and Replacement, 3-9 Ceiling Grill -- Ducted, 3-4 Ceiling Grill -- Free Blow, 3-1 Ceiling Panel -- Free Blow, 3-2 CEILING UNIT -- DUCTED SYSTEMS, 3-4 CEILING UNIT -- FREE BLOW , 3-1 Cleaning, 3-1 Compressor , 3-6, 3-13 Condenser Fan, 3-7 Control Box -- Ducted, 3-4 Control Box -- Upper Unit, 3-6 Controls, 3-1 Cool Only Thermostat, 3-15 LCD DISPLAY, 3-15, 3-16 Leaks, 3-1
M
Main Pcb Board, 3-5 Master Control Switch, 3-2 Motor , 3-7 Mounting, 3-1
P
Painting, 3-1 PCB Display , 3-5 PREVENTATIVE MAINTENANCE, 3-1
R
REFRIGERANT CYCLE, 1-9, 1-10
D
Design Change, 1-1
S
Serial Number, 1-1 SERVICE -- GENERAL, 3-1 SERVICE -- UPPER UNIT -- LOW PROFILE, 3-10 SERVICE AND MAINTENANCE, 3-1 START--UP, 1-9
E
Evaporator Blower Wheel, 3-8 Exterior Cover, 3-5, 3-10, 3-15
T F
Filter Removal -- Free Blow, 3-1 Filter Removal -- Ducted, 3-4 Fuse Removal -- Ducted, 3-5 THERMOSTAT INSTALLATION AND START--UP INSTRUCTIONS (WALL MOUNTED), 3-15 TROUBLESHOOTING, 2-1, 2-3
U
Upper Scroll Assembly, 3-7, 3-10, 3-11, 3-12, 3-13
H
Heat Strip, 3-3 Heat/Cool Thermostat, 3-15
W
WIRING SCHEMATICS, 4-1 T--298
Index -1
Carrier Transport Air Conditioning 50 Grumbacher Road York PA 17402 USA Tel: 1-800-673-2431 Fax: 1-717-764-0401
Carrier Transicold Division, Carrier Corporation Transport Air Conditioning Group P.O. Box 4805 Syracuse, N.Y. 13221 U.S A www.carrier.transicold.com
A member of the United Technologies Corporation family. Stock symbol UTX 2006 Carrier Corporation D Printed in U. S. A. 0606