Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Model DUC-AUS: Dual Check Valves

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

RP/IS-DUC-AUS

Model DUC-AUS
Dual Check Valves
Water Pressure Reducing Valve Water Meter Model DUC-AUS to Sill Cock

Water Supply

Main Supply

Installation Instructions
A. Watts dual check valves may be installed in either a vertical or a horizontal position. Series DUC-AUS should be installed downstream of the water meter and of the water pressure regulator. All outlets including sill cocks must be downstream of the Model DUC-AUS. B. They should always be installed in an accessible location to facilitate the removal for servicing and testing. C. Pipe lines should be thoroughly flushed to remove foreign material before installing the unit. D. Protect from freezing E. Ensure that valve is installed in proper flow direction. Refer to flow direction arrow on valve nameplate or body. F. When installing valve in pipe line, only use wrenching flats provided. Do not apply wrench to body of valve. This will prevent distorting the valve body and component parts. G. These valves incorporate an O-ring union seal that requires minimum tightening of union nut. Do not overtighten. H. These valves contain plastic check modules and should never be directly sweated into the line. Sweat fit adapters should be sweated into the line prior to valve installation. I. Avoid improper application and excessive pipe sealants such as Teflon tape and pipe dope.

IMPORTANT: Inquire with governing authorities for local installation requirements. NOTE: When a pressure reducing valve or dual check valve is installed in the supply line, it creates a closed system which makes plumbing code compliance imperative for system safety. Special attention must be given by all concerned to assure pressure relief protection is provided to protect water heater equipment. It is important to make certain an approved ANSI Z21.22 temperature and pressure relief valve is installed on the storage water heater. High System Pressure If the downstream system pressure is higher than the set pressure under no flow conditions, the cause could be thermal expansion, pressure creep or dirt/debris on the seat. Thermal expansion occurs whenever water is heated in a closed system. The system is closed when supply pressure exceeds 1034 kPa, or a check valve or backflow preventer is installed in the supply piping. You must make provisions for pressure relief protection of your plumbing system and components. The use of a relief valve such as the Watts 530C, BRV, Governor 80, or 3L or potable water expansion tank such as the Watts DET, PLT or DETA may be required. To determine if this is the result of thermal expansion, try briefly opening the cold water tap. If the increased pressure is caused by thermal expansion, the pressure will immediately be relieved and the system will return to the set pressure. Watts offers a pressure test gauge, model 276H300 to assist you in determining if you have high water pressure. The 276H300 when attached to a hose bibb registers the highest pressure reading over the period of time it is left on the system. Watts 276H300 NOTE: Under no circumstances should the Governor 80 be used in place of a water heater relief valve.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

Service, Replacement Parts and Maintenance


Servicing Models DUC-AUS
1. Remove the Model DUC-AUS from the line (union nut and adapter remain in the line). 2. Remove the two check modules by pressing firmly from the outlet end (end with wrench pads). O-ring seals will be removed with the removal of modules from the body. CAUTION: To prevent damage to O-ring seals, do not attempt to pry the O-ring seal free before removing check modules. NOTE: Complete check module assemblies are available as replacement parts. It is recommended that if check modules are fouled, that the entire check module be replaced. 3. Inspect body bore and clean surfaces of any foreign material. 4. Using silicone grease, apply small amount to each exterior surface of the O-ring seals. If O-ring is to be replaced, lubricate as above. A light application of silicone grease to inlet of body bore is beneficial. Do not lubricate seat of seat disc. NOTE: Only US FDA approved silicone grease should be used and is furnished with each Watts Model DUC-AUS. 5. Reinsert the check modules and O-rings into body in direction of flow. NOTE: 1st and 2nd check modules are identical and interchangeable. Do not overtighten union nut.

Series DUC-AUS
Individual O-ring Check Seals

O-ring Module seal

O-ring 2nd Check Module

1st Check Module

Represented by:

Fluidflo Pty Ltd. 107-109 Woodlands Drive Braeside, Victoria 3195 Phone: 1300-662-155 Fax: 1300-799-356 Web: www.fluidflo.com.au

Limited Warranty: Watts Regulator Co. (the Company) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge. THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product. Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

Backflow Prevention Products

USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

RP/IS-DUC-AUS 0845

EDP# 1915934

Watts, 2008

You might also like