Fiber Optic Cable Supplement

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

2

0
0
2
Fiber Optic Cable Supplement

Fiber Optic Cable:


General Information ......................................................2
Interconnect, 1-4 Fiber..................................................3
Distribution, 6-12 Fiber..................................................4
Distribution, 24-72 Fiber................................................5
Indoor/Outdoor, 4-12 Fiber............................................6
Indoor/Outdoor, 24-144 Fiber .......................................7
Outside Plant Armored, 4-12 Fiber ...............................8
Outside Plant Armored, 24-144 Fiber............................9
Outside Plant Dielectric, 4-12 Fiber............................10
Outside Plant Dielectric, 24-144 Fiber .........................11
Buffer Tube Splitter Kits ..............................................12

Summary
n Fiber Optic Cables
Interconnect, distribution,
indoor/outdoor and outside
plant types
Meet all industry specifications
including: ANSI, IEEE, ATM,
Fibre Channel,
Bellcore/Telcordia, TIA/EIA,
ISO/IEC and ICEA

FIBER OPTIC CABLE SUPPLEMENT


FIBER OPTIC CABLE SUPPLEMENT
2

Optical Fiber Cabling Architecture


Horizontal Cabling
Horizontal cabling runs from the
telecommunications room or patch panel to
individual workstations or groups of
workstations.
Backbone Cabling
Backbone cabling connects a group of
telecommunications rooms and can be run
vertically (floor to floor) or horizontally.
Campus Cabling
Campus cabling connects two or more buildings.
The cables can be installed in aerial, underground conduit, or direct buried applications.

Product Facts
n AMP NETCONNECT
Fiber Optic Cables are
tested and designed to
current and proposed
industry specifications for
premise cabling, network
and telecommunications
applications, including:
ANSI X3T9.5 PMD (FDDI)
IEEE 802.3
Gigabit Ethernet
10 Gigabit Ethernet

ATM (155 & 622 Mb/s)


Fiber Channel FC-PH
Telcordia GR-409-CORE
(Indoor)
Telcordia GR-20-CORE
(Outdoor)
TIA/EIA-568-B
ISO/IEC 11801:2000
ICEA-596
ICEA-640
ICEA-696
ANSI X3.166-1990

AMP NETCONNECT Fiber Optic Cables


AMP NETCONNECT multimode fiber cables contain the highest quality optical fiber, and offer the best
performance for laser-based
and LED-based applications. The fiber has been engineered to support applications using the newest laser and
VCSEL technologies (such as Gigabit Ethernet and Ten Gigabit Ethernet), while providing advanced performance
for legacy applications such as FDDI and Token Ring. The 62.5/125m fiber is guaranteed for transmission
distances up to 300m in Gigabit Ethernet compliant systems at 850nm and up to 550m at 1300nm. The 50/125m
fiber is guaranteed for transmission distances up to 600m in Gigabit Ethernet compliant systems at both 850 and
1300nm. Both of the fibers can support Ten Gigabit Ethernet and can operate at significantly greater distances
(greater than 2000m) at slower protocols such as Fast Ethernet. A new fiber type, 850nm Laser-optimized

Fiber
Multimode 62.5/125m
Multimode 50/125m
Multimode 50/125m XG (850nm Laser-optimized)

Gigabit Ethernet
@ 850nm
300m
600m
600m

Gigabit Ethernet
@ 1300nm
550m
600m
600m

10 Gigabit Ethernet Serial


@ 850nm
33m
82m
300m

10 Gigabit Ethernet
WDM @ 1300nm
300m
300m
300m

Optical Fiber Cable Specifications


Singlemode
(1300/1550nm)

Multimode 50/125 XG
(850nm Laser-optimized)
(850/1300nm )

Multimode 50/125
(50/125m)
(850/1300nm )

Multimode 62.5/125
(62.5/125m)
(850/1300nm )

Indoor Cables
Maximum Attenuation (dB/km)
OFL Bandwidth (MHz km)
Laser Bandwidth (MHz km)

0.7/0.7
-/-/-

3.5/1.5
1500/500
2000/-

3.5/1.5
500/500
-/-

3.5/1.5
200/500
-/-

Indoor/Outdoor and OSP Loose Tube Cables


Maximum Attenuation (dB/km)
OFL Bandwidth (MHz km)
Laser Bandwidth (MHz km)

0.5/0.3
-/-/-

3.5/1.5
1500/500
2000/-

3.5/1.5
500/500
-/-

3.5/1.5
200/500
-/-

Optical Fiber Cable Temperature Ranges


Interconnect (Tight Buffered) Cables

Indoor, Distribution (Tight Buffered) Cables

Storage
Operating
Installation
Storage
Operating
Installation

Indoor/Outdoor Cables

Storage
Operating
Installation

OSP (Loose Tube) Cables

Storage
Operating
Installation

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

Riser
-40C to +65C (-40F to +149F)
-20C to +50C (-4F to +122F)
-20C to +50C (-4F to +122F)
-40C to +65C (-40F to +149F)
-20C to +50C (-4F to +122F)
-20C to +50C (-4F to +122F)
Stranded Cables
-40C to +70C (-40F to +160F)
-40C to +70C (-40F to +160F)
-20C to +60C (-4F to +140F)
Stranded Cables
-40C to +70C (-40F to +160F)
-40C to +70C (-40F to +160F)
-20C to +60C (-4F to +140F)

Plenum
-40C to +65C (-40F to +149F)
-20C to +50C (-4F to +122F)
-20C to +50C (-4F to +122F)
-40C to +65C (-40F to +149F)
0C to +50C (32F to +122F)
0C to +50C (32F to +122F)

FIBER OPTIC CABLE SUPPLEMENT

Fiber
Tight
Buffering (900m)

Fiber
Tight
Buffering (900m)
Aramid Strength
Members

Aramid Strength
Members
Outer Jacket

Outer Jacket

Simplex Cable

2-Fiber
Fiber
Fiber

Tight
Buffering (900m)

Tight
Buffering (900m)

Aramid Strength
Members

Aramid Strength
Members

Outer Jacket

Outer Jacket

4-Fiber

Zipcord Cable

Simplex (2.0mm)
Fiber
Count

Unit Count
Units (Fibers/Unit)

UL/NEC
Ratings
Riser
Singlemode
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum

AMP NETCONNECT
Part Number
0-1664006-6
0-1664007-6
2-1664008-1
2-1664009-1
8-1664008-1
8-1664009-1
1-1664010-1
1-1664011-1

Weight
kg/km (lb/kft)
5 (3)
6 (4)
5 (3)
6 (4)
5 (3)
6 (4)
5 (3)
6 (4)

Riser
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum

0-1664000-6
0-1664001-6
2-1664002-1
2-1664003-1
8-1664002-1
8-1664003-1
1-1664004-1
1-1664005-1

8 (5)
9 (6)
8 (5)
9 (6)
8 (5)
9 (6)
8 (5)
9 (6)

2.9 (0.11)

220 (50)

55 (12.5)

58 (2.8)

29 (1.1)

Riser
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum

0-1664018-6
0-1664019-6
2-1664020-1
2-1664021-1
8-1664020-1
8-1664021-1
1-1664022-1
1-1664023-1

6 (4)
8 (5)
6 (4)
8 (5)
6 (4)
8 (5)
6 (4)
8 (5)

2.0x4.0
(0.08x0.16)

220 (50)

55 (12.5)

40 (2.2)

20 (0.8)

2 (1)

Riser
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum

0-1664012-6
0-1664013-6
2-1664014-1
2-1664015-1
8-1664014-1
8-1664015-1
1-1664016-1
1-1664017-1

15 (10)
18 (12)
15 (10)
18 (12)
15 (10)
18 (12)
15 (10)
18 (12)

2.9x5.8
(0.11x0.22)

220 (50)

55 (12.5)

58 (2.2)

29 (1.1)

1 (2)

Riser
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum

0-1664024-6
0-1664025-6
2-1664026-1
2-1664027-1
8-1664026-1
8-1664027-1
1-1664028-1
1-1664029-1

19 (13)
23 (16)
19 (13)
23 (16)
19 (13)
23 (16)
19 (13)
23 (16)

4.8

220 (50)

55 (12.5)

95 (3.8)

48 (1.9)

Riser
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum

0-1664030-6
0-1664031-6
2-1664032-1
2-1664033-1
8-1664032-1
8-1664033-1
1-1664034-1
1-1664035-1

21 (14)
25 (17)
21 (14)
25 (17)
21 (14)
25 (17)
21 (14)
25 (17)

4.8

220 (50)

55 (12.5)

95 (3.8)

48 (1.9)

1 (1)

Fiber
Type

Diameter
mm (in)

Product Facts
n Suitable for pigtails, patch cords,
horizontal cabling and internal
equipment connections
n Suitable for direct termination
with epoxy/polish type,
LightCrimp, LightCrimp Plus
and MT-RJ Connectors
n High performance singlemode
and multimode fibers meet all
industry performance standards
n Strippable buffer coating allows
for easy connectorization
n Aramid yarn reinforcement
n UL and cUL listed OFNR
(Riser)/OFNP(Plenum)
n Designed and tested in
accordance with TIA/EIA-568-B,
Telcordia GR-409-CORE, IEC
793-1/794-1 and ISO/IEC
11801:2000

2.0 (0.08)

Tensile Load N (lbf)


Installation Long Term

220 (50)

55 (12.5)

Bending Radius mm (in)


Installation Long Term

40 (1.6)

20 (0.8)

Simplex (2.9mm)
Singlemode

1 (1)

Zipcord (2.0mm)
Singlemode

2 (1)

Zipcord (2.9mm)
Singlemode

2-Fiber
Singlemode

4-Fiber
Singlemode

1 (4)

FIBER OPTIC CABLE SUPPLEMENT

Interconnect, 1- 4 Fiber

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

FIBER OPTIC CABLE SUPPLEMENT


FIBER OPTIC CABLE SUPPLEMENT

Distribution, 6 - 12 Fiber
Product Facts
n Suitable for horizontal and
intrabuilding backbone cabling,
and for direct termination in
multi-user outlets
n Suitable for direct termination with
epoxy/polish-type, LightCrimp,
LightCrimp Plus and MT-RJ
Connectors
n High performance singlemode
and multimode fibers meet all
industry performance standards
n Strippable 900m tight
buffer coating allows for
easy connectorization
n TIA color-coded fibers
for easy identification
n Hybrid cables provide a
built-in upgrade for future
applications that will
require singlemode fibers
n UL and cUL listed OFNR
(Riser)/OFNP(Plenum)
n Designed and tested in
accordance with TIA/EIA-568-B,
Telcordia GR-409-CORE,
IEC 793-1/794-1, ICEA-596 and
ISO/IEC 11801:2000

Fibers
Tight Buffering (900m)
Strength Members
Outer Jacket

Distribution Fiber Optic Cables

Fiber
Unit Count
Count Unit (Fibers/Unit)

1 (6)

1 (8)

12

1 (12)

Fiber
Type

UL/NEC
Ratings
Riser
Singlemode
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum
Riser
Singlemode
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum
Riser
Singlemode
Plenum
Multimode
Riser
50/125m
Plenum
XG Multimode Riser
50/125m
Plenum
Multimode
Riser
62.5/125m Plenum

Weight
AMP NETCONNECT
Part Number
kg/km (lb/kft)
0-1664036-6
22 (15)
0-1664037-6
24 (16)
2-1664038-1
22 (15)
2-1664039-1
24 (16)
8-1664038-1
22 (15)
8-1664039-1
24 (16)
1-1664040-1
22 (15)
1-1664041-1
24 (16)
0-1664042-6
24 (16)
0-1664043-6
26 (18)
2-1664044-1
24 (16)
2-1664045-1
26 (18)
8-1664044-1
24 (16)
8-1664045-1
26 (18)
1-1664046-1
24 (16)
1-1664047-1
26 (18)
0-1664048-6
36 (24)
0-1664049-6
46 (31)
2-1664050-1
36 (24)
2-1664051-1
46 (31)
8-1664050-1
36 (24)
8-1664051-1
46 (31)
1-1664052-1
36 (24)
1-1664053-1
46 (31)

Diameter
mm (in)

4.8 (0.19)

4.9 (0.19)

6.2 (0.24)

Tensile Load N (lbf)


Installation Long Term
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)
667 (150)
167 (38)
445 (100)
111 (25)

Note: Other cable designs (including hybrid) available. Call for more information.

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

Bending Radius mm (in)


Installation Long Term

96 (3.8)

48 (1.9)

108 (4.2)

54 (2.1)

124 (4.8)

62 (2.4)

FIBER OPTIC CABLE SUPPLEMENT

Dielectric Central
Strength Member
Fibers

Tight Buffering (900m)


Strength Members
Protective Jacket
Binder
Outer Jacket

Product Facts
n Suitable for horizontal and
intrabuilding backbone
cabling, and for direct
termination in multi-user
outlets
n Suitable for direct
termination with
epoxy/polish-type,
LightCrimp, LightCrimp
Plus and MT-RJ connectors
n High performance
singlemode and multimode
fibers meet all industry
performance standards
n Strippable 900m tight
buffer coating allows for
easy connectorization

n TIA color-coded fibers for


easy identification
n Hybrid cables provide a
built-in upgrade for future
applications that will require
singlemode fibers
n UL and cUL listed OFNR
(Riser)/OFNP(Plenum)
n Designed and tested in
accordance with TIA/EIA568-B, Telcordia GR-409CORE, IEC 793-1/794-1,
ICEA-596 and ISO/IEC
11801:2000

Multi-Unit Distribution Fiber Optic Cables


Fiber
Unit Count
Count Unit (Fibers/Unit)

2 (12)

24

1 SM (12)
1 MM (12)

4 (6)

2 SM (6)
2 MM (6)

36

6 (6)

2 SM (6)
4 MM (6)

48

4 (12)

72

6 (12)

2 SM (12)
4 MM (12)

UL/NEC AMP NETCONNECT


Weight
Ratings
Part Number
kg/km (lb/kft)
Riser
0-1664054-6
87 (59)
Singlemode Plenum
0-1664055-6
117 (79)
Multimode
Riser
2-1664056-1
87 (59)
50/125m Plenum
2-1664057-1
117 (79)
XG Multimode Riser
8-1664056-1
87 (59)
50/125m Plenum
8-1664057-1
117 (79)
Multimode
Riser
1-1664058-1
87 (59)
62.5/125m Plenum
1-1664059-1
117 (79)
Hybrid
Riser
4-1664084-1
87(59)
Singlemode- Plenum
4-1664085-1
117 (79)
62.5/125m
Riser
0-1664060-6
160 (109)
Singlemode Plenum
0-1664061-6
200 (140)
Multimode
Riser
2-1664062-1
160 (109)
50/125m Plenum
2-1664063-1
200 (140)
XG Multimode Riser
8-1664062-1
160 (109)
50/125m Plenum
8-1664063-1
200 (140)
Multimode
Riser
1-1664064-1
160 (109)
62.5/125m Plenum
1-1664065-1
200 (140)
Hybrid
Riser
4-1664086-1
160 (109)
Singlemode- Plenum
4-1664087-1
200 (140)
62.5/125m
Riser
0-1664066-6
210 (140)
Singlemode Plenum
0-1664067-6
260 (180)
Multimode
Riser
2-1664068-1
210 (140)
50/125m Plenum
2-1664069-1
260 (180)
XG Multimode Riser
8-1664068-1
210 (140)
50/125m Plenum
8-1664069-1
260 (180)
Multimode
Riser
1-1664070-1
210 (140)
62.5/125m Plenum
1-1664071-1
260 (180)
Hybrid
Riser
4-1664088-1
210 (140)
Singlemode- Plenum
4-1664089-1
260 (180)
62.5/125m
Riser
0-1664072-6
250 (170)
Singlemode Plenum
0-1664073-6
310 (210)
Multimode
Riser
2-1664074-1
250 (170)
50/125m Plenum
2-1664075-1
310 (210)
XG Multimode Riser
8-1664074-1
250 (170)
50/125m Plenum
8-1664075-1
310 (210)
Multimode
Riser
1-1664076-1
250 (170)
62.5/125m Plenum
1-1664077-1
310 (210)
Riser
0-1664078-6
380 (260)
Singlemode Plenum
0-1664079-6
460 (310)
Multimode
Riser
2-1664080-1
380 (260)
50/125m Plenum
2-1664081-1
460 (310)
XG Multimode Riser
8-1664080-1
380 (260)
50/125m Plenum
8-1664081-1
460 (310)
Multimode
Riser
1-1664082-1
380 (260)
62.5/125m Plenum
1-1664083-1
460 (310)
Hybrid
Riser
4-1664090-1
380 (260)
Singlemode- Plenum
4-1664091-1
460 (310)
62.5/125m
Fiber
Type

Diameter
mm (in)

7.2 x 13.4

13.2 (0.54)

16.4 (0.65)

18.2 (0.72)

22.0 (0.86)

Tensile Load N (lbf)


Installation Long Term
1335 (300)
334 (75)
667 (150)
167 (38)
1335 (300)
334 (75)
667 (150)
167 (38)
1335 (300)
334 (75)
667 (15)
167 (38)
1335 (300)
334 (75)
667 (150)
167 (38)
1335 (300)
334 (75)
667 (150)

167 (38)

1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)

334 (75)
167 (38)
334 (75)
167 (38)
334 (175)
167 (38)
334 (75)
167 (38)
334 (75)

667 (150)

167 (38)

1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)

334 (75)
167 (38)
334 (75)
167 (38)
334 (75)
167 (38)
334 (75)
167 (38)
334 (75)

667 (150)

167 (38)

1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)
667 (150)
1335 (300)

334 (75)
167 (38)
334 (75)
167 (38)
334 (75)
167 (38)
334 (75)
167 (38)
334 (75)
167 (38)
334 (75)
167 (38)
334 (75)
167 (38)
334 (75)
167 (38)
334 (75)

667 (150)

167 (38)

Bending Radius mm (in)


Installation Long Term

144 (5.6)

FIBER OPTIC CABLE SUPPLEMENT

Distribution, 24 -72 Fiber

72 (2.8)

201 (8.0)

134 (5.3)

348 (13.8)

174 (6.9)

360 (14.2)

180 (7.1)

432 (17.0)

216 (8.5)

Note: Other cable designs (including hybrid) available. Call for more information.

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

FIBER OPTIC CABLE SUPPLEMENT


FIBER OPTIC CABLE SUPPLEMENT

Indoor/Outdoor, 4-12 Fiber

Fibers
Filled Buffer Tube
Water-Blocking Outer
Strength Members
Strength Members
Outer Jacket

Indoor/Outdoor Single Loose Tube


Cables

Product Facts
n Suitable for:
Outdoor to indoor cable
links without the need
for a building entrance
splice point
Intrabuilding links in a
campus environment
(ducted or direct burial)
Aerial links (when used
with a messenger strand)
Local loop and feeder
networks
Outdoor areas with
intermittent flooding
or moisture
Environments with
severe temperature
fluctuations
Drop or service cables
n High performance
singlemode and
multimode fibers
meet all industry
performance standards
n TIA color-coded fibers
for easy identification

n Gel-filled buffer tube for


water penetration
protection
n Small diameter single tube
construction saves space
inside ducts
n Flame retardant UVprotected jacket for harsh
outdoor environment
n Hybrid cables
provide a built-in upgrade
for future applications
that will require
singlemode fibers
n UL and cUL listed OFNR
(Riser)
n Designed and tested
in accordance with TIA/EIA568-B,
Telcordia GR-409-CORE,
GR-20-CORE,
IEC 793-1/794-1 and
ISO/IEC 11801:2000
n Compatible with Splitter Kits
[see page 12]

Single Loose Tube


Fiber
Count
4

12

Unit Count
Units (Fibers/Unit)

Fiber
UL/NEC AMP NETCONNECT
Weight
Type
Ratings
Part Number
kg/km (lb/kft)
Singlemode
Riser
0-1664092-5
Multimode 50/125m
Riser
2-1664093-5
1 (4)
71 (48)
XG Multimode 50/125m Riser
8-1664093-5
Multimode 62.5/125m
Riser
1-1664094-5
Singlemode
Riser
0-1664095-5
Multimode 50/125m
Riser
2-1664096-5
1 (6)
71 (48)
XG Multimode 50/125m Riser
8-1664096-5
Multimode 62.5/125m
Riser
1-1664097-5
Singlemode
Riser
0-1664098-5
Multimode 50/125m
Riser
2-1664099-5
1 (8)
71 (48)
XG Multimode 50/125m Riser
8-1664099-5
Multimode 62.5/125m
Riser
1-1664100-5
Singlemode
Riser
0-1664101-5
Multimode 50/125m
Riser
2-1664102-5
1 (12)
XG Multimode 50/125m Riser
8-1664102-5
71 (48)
Multimode 62.5/125m
Riser
1-1664103-5
Hybrid SinglemodeRiser
4-1664104-5
1 SM (6)/MM (6)
62.5/125m

Diameter
mm (in)

Tensile Load N (lbf)


Installation Long Term

8.5 (0.34)

1800 (400)

890 (200)

179 (6.8)

85 (3.4)

8.5 (0.34)

1800 (400)

890 (200)

179 (6.8)

85 (3.4)

8.5 (0.34)

1800 (400)

890 (200)

179 (6.8)

85 (3.4)

8.5 (0.34)

1800 (400)

890 (200)

179 (6.8)

85 (3.4)

Note: Other cable designs (including hybrid) available. Call for more information.

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

Bending Radius mm (in)


Installation Long Term

FIBER OPTIC CABLE SUPPLEMENT

Dielectric Central
Strength Member
Water-Blocking Materials
Filled Buffer Tubes
Fibers
Flame Barrier Tapes
Water-Blocking Outer
Strength Members
Outer Jacket

Indoor/Outdoor Stranded Loose Tube


Fiber Optic Cables

Product Facts
n Suitable for:
Outdoor to indoor cable
links without the need
for a building entrance
splice point
Intrabuilding links
(ducted or direct burial)
in a campus environment
Aerial links (when used
with a messenger strand)
Local loop and feeder
networks
Outdoor areas with
intermittent flooding
or moisture
Environments with severe
temperature fluctuations
Drop or service cables
n High performance
singlemode and multimode
fibers meet all industry
performance standards
n TIA color-coded fibers
in TIA color-coded tubes
for easy identification

n Gel-filled buffer tubes and


water swellable yarns for
water penetration protection
n Flame retardant UVprotected jacket for
harsh outdoor environment
n Hybrid cables provide
a built-in upgrade for future
applications
that will require singlemode
fibers
n UL and cUL listed OFNR
(Riser)
n Designed and tested
in accordance with TIA/EIA568-B,
Telcordia GR-409-CORE,
GR-20-CORE,
IEC 793-1/794-1 and
ISO/IEC 11801:2000
n Compatible with Splitter Kits
[see page 12]
n Reverse oscillating lay
tube construction for
ease of mid-span entry

Stranded Loose Tube


Fiber
Count

24

Unit Count
Unit (Fibers/Unit)
2 (12)
1 SM (12)
1 MM (12)

36

3 (12)
1 SM (12)
2 MM (12)

48

72

4 (12)

6 (12)
2 SM (12)
4 MM (12)

96

8 (12)

144

12 (12)

Fiber
UL/NEC AMP NETCONNECT
Weight
Type
Ratings
Part Number
kg/km (lb/kft)
Singlemode
Riser
0-1664105-5
Multimode 50/125m
Riser
2-1664106-5
XG Multimode 50/125m Riser
8-1664106-5
144 (98)
Multimode 62.5/125m
Riser
1-1664107-5
Hybrid
Riser
4-1664123-5
Singlemode-62.5/125m
Singlemode
Riser
0-1664108-5
Multimode 50/125m
Riser
2-1664109-5
XG Multimode 50/125m Riser
8-1664109-5
144 (98)
Multimode 62.5/125m
Riser
1-1664110-5
Hybrid
Riser
4-1664124-5
Singlemode-62.5/125m
Singlemode
Riser
0-1664111-5
Multimode 50/125m
Riser
2-1664112-5
144 (98)
XG Multimode 50/125m Riser
8-1664112-5
Multimode 62.5/125m
Riser
1-1664113-5
Singlemode
Riser
0-1664114-5
Multimode 50/125m
Riser
2-1664115-5
XG Multimode 50/125m Riser
8-1664115-5
168 (110)
Multimode 62.5/125m
Riser
1-1664116-5
Hybrid
Riser
4-1664125-5
Singlemode-62.5/125m
Singlemode
Riser
0-1664117-5
Multimode 50/125m
Riser
2-1664118-5
277 (190)
XG Multimode 50/125m Riser
8-1664118-5
Multimode 62.5/125m
Riser
1-1664119-5
Singlemode
Riser
0-1664120-5
Multimode 50/125m
Riser
2-1664121-5
305 (210)
XG Multimode 50/125m Riser
8-1664121-5
Multimode 62.5/125m
Riser
1-1664122-5

Diameter
mm (in)

Tensile Load N (lbf)


Bending Radius mm (in)
Installation Long Term Installation Long Term

12.3 (0.48)

2700 (600)

890 (200)

246 (9.7)

123 (4.8)

12.3 (0.48)

2700 (600)

890 (200)

246 (9.7)

123 (4.8)

12.3 (0.48)

2700 (600)

890 (200)

246 (9.7)

123 (4.8)

13.1 (0.51)

2700 (600)

890 (200)

261 (10.2)

131 (5.1)

17.0 (0.67)

2700 (600)

890 (200)

304 (12.0)

152 (6.0)

18.8 (0.74)

2700 (600)

890 (200)

370 (14.6)

185 (7.3)

Note: Other cable designs (including hybrid) available. Call for more information.

For More Information, Call 1-800-5530938 www.ampnetconnect.com

FIBER OPTIC CABLE SUPPLEMENT

Indoor/Outdoor, 24 -144 Fiber

FIBER OPTIC CABLE SUPPLEMENT


FIBER OPTIC CABLE SUPPLEMENT

Outside Plant (OSP)


Armored, 4-12 Fiber

Fibers
Filled Buffer Tube
Water-Blocking Outer
Strength Members
Strength Members
Corrugated Armor
Outer Jacket

OSP Armored Single Loose Tube


Fiber Optic Cable

Product Facts
n Suitable for:
Intrabuilding links
(ducted or direct burial)
in a campus environment
Aerial links (when used
with a messenger strand)
Local loop and feeder
networks
Outdoor areas with
intermittent flooding
or moisture
Environments with severe
temperature fluctuations
Drop or service cables
n High performance
singlemode and
multimode fibers meet all
industry performance
standards
n TIA color-coded fibers
for easy identification

n Dry water-blocking
technology
n Small diameter single tube
construction saves space
inside ducts
n Polyethylene UV-protected
jacket for harsh outdoor
environment
n Low friction jacket
for ease of pulling
through ducts
n Armored construction
n Designed and tested
in accordance with
TIA/EIA-568-B,
Telcordia GR-20-CORE,
IEC 793-1/794-1,
ICEA-640 and
ISO/IEC 11801:2000
n Compatible with Splitter
Kits [see page 12]

8
Armored Single Loose Tube
Fiber
Count

Unit Count
Units (Fibers/Unit)

1 (4)

1 (6)

1 (8)

12

1 (12)

Fiber
UL/NEC AMP NETCONNECT
Weight
Diameter
Type
Ratings
Part Number
kg/km (lb/kft) mm (in)
Singlemode
OSP
0-1664160-5
Multimode 50/125m
OSP
2-1664161-5
XG Multimode 50/125m OSP
8-1664161-5
Multimode 62.5/125m
OSP
1-1664162-5
Singlemode
OSP
0-1664163-5
Multimode 50/125m
OSP
2-1664164-5
XG Multimode 50/125m OSP
8-1664164-5
Multimode 62.5/125m
OSP
1-1664165-5
120 (78) 10.7 (0.42)
Singlemode
OSP
0-1664166-5
Multimode 50/125m
OSP
2-1664167-5
XG Multimode 50/125m OSP
8-1664167-5
Multimode 62.5/125m
OSP
1-1664168-5
Singlemode
OSP
0-1664169-5
Multimode 50/125m
OSP
2-1664170-5
XG Multimode 50/125m OSP
8-1664170-5
Multimode 62.5/125m
OSP
1-1664171-5

Tensile Load N (lbf)


Installation Long Term

Bending Radius mm (in)


Installation Long Term

2700 (600)

214 (8.4)

Note: Other cable designs (including hybrid) available. Call for more information.

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

890 (200)

107 (4.2)

FIBER OPTIC CABLE SUPPLEMENT

Dielectric Central
Strength Member
Water-Blocking Materials
Filled Buffer Tubes
Fibers
Outer Strength Members
Corrugated Armor
Outer Jacket

OSP Armored Stranded Loose Tube


Fiber Optic Cable

Product Facts
n Suitable for
Intrabuilding links in a
campus environment
(ducted or direct burial)
Aerial links (when used
with a messenger strand)
Local loop and feeder
networks
Outdoor areas with
intermittent flooding
or moisture
Environments with
severe temperature
fluctuations
Drop or service cables
n High performance
singlemode and multimode
fibers meet all industry
performance standards
n TIAcolor-coded fibers in TIA
color-coded buffer tubes for
easy identification

n Dry water-blocking
technology
n Polyethylene UV-protected
jacket for harsh outdoor
environment
n Low friction jacket for ease
of pulling through ducts
n Armored construction
n Reverse oscillating
lay tube construction
for ease of mid-span entry
n Designed and tested
in accordance with
TIA/EIA-568-B,
Telcordia GR-20-CORE,
IEC 793-1/794-1,
ICEA-640 and
ISO/IEC 11801:2000
n Compatible with Splitter Kits
[see page 12]

FIBER OPTIC CABLE SUPPLEMENT

Outside Plant (OSP)


Armored, 24-144 Fiber

9
Armored Stranded Loose Tube
Fiber
Count

Unit Count
Units (Fibers/Unit)

Fiber
UL/NEC AMP NETCONNECT
Weight
Type
Ratings
Part Number
kg/km (lb/kft)
Singlemode
OSP
0-1664172-5
Multimode 50/125m
OSP
2-1664173-5
170 (120)
XG Multimode 50/125m OSP
8-1664173-5
Multimode 62.5/125m
OSP
1-1664174-5
Singlemode
OSP
0-1664175-5
Multimode 50/125m
OSP
2-1664176-5
160 (110)
XG Multimode 50/125m OSP
8-1664176-5
Multimode 62.5/125m
OSP
1-1664177-5
Singlemode
OSP
0-1664178-5
Multimode 50/125m
OSP
2-1664179-5
160 (110)
XG Multimode 50/125m OSP
8-1664179-5
Multimode 62.5/125m
OSP
1-1664180-5
Singlemode
OSP
0-1664181-5
Multimode 50/125m
OSP
2-1664182-5
200 (140)
XG Multimode 50/125m OSP
8-1664182-5
Multimode 62.5/125m
OSP
1-1664183-5
Singlemode
OSP
0-1664184-5
Multimode 50/125m
OSP
2-1664185-5
230 (160)
XG Multimode 50/125m OSP
8-1664185-5
Multimode 62.5/125m
OSP
1-1664186-5
Singlemode
OSP
0-1664187-5
Multimode 50/125m
OSP
2-1664188-5
350 (240)
XG Multimode 50/125m OSP
8-1664188-5
Multimode 62.5/125m
OSP
1-1664189-5

Diameter
mm (in)

Tensile Load N (lbf)


Installation Long Term

Bending Radius mm (in)


Installation Long Term

24

2 (12)

13.4 (0.53)

2700 (600)

890 (200)

268 (10.6)

134 (5.3)

36

3 (12)

13.4 (0.53)

2700 (600)

890 (200)

268 (10.6)

134 (5.3)

48

4 (12)

13.4 (0.53)

2700 (600)

890 (200)

268 (10.6)

134 (5.3)

72

6 (12)

14.2 (0.56)

2700 (600)

890 (200)

284 (11.2)

142 (5.6)

96

6 (12)

16.0 (0.63)

2700 (600)

890 (200)

320 (12.6)

160 (6.3)

144

12 (12)

20.0 (0.78)

2700 (600)

890 (200)

392 (15.4)

196 (7.7)

Note: Other cable designs (including hybrid) available. Call for more information.

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

FIBER OPTIC CABLE SUPPLEMENT


FIBER OPTIC CABLE SUPPLEMENT

Outside Plant (OSP)


Dielectric, 4-12 Fiber

Fibers
Filled Buffer Tube
Water-Blocking Outer
Strength Members
Strength Members
Outer Jacket

OSP Dielectric Single Loose Tube


Fiber Optic Cable

Product Facts
n Suitable for:
Intrabuilding links
(ducted or direct burial)
in a campus environment
Aerial links (when used
with a messenger strand)
Local loop and feeder
networks
Outdoor areas with
intermittent flooding
or moisture
Environments with severe
temperature fluctuations
Drop or service cables
n High performance
singlemode and
multimode fibers meet all
industry performance
standards
n TIA color-coded fibers
for easy identification

n Dry water-blocking
technology
n Small diameter single tube
construction saves space
inside ducts
n Polyethylene UV-protected
jacket for harsh outdoor
environment
n Low friction jacket
for ease of pulling
through ducts
n All-Dielectric construction
n Designed and tested
in accordance with
TIA/EIA-568-B,
Telcordia GR-20-CORE,
IEC 793-1/794-1,
ICEA-640 and
ISO/IEC 11801:2000
n Compatible with Splitter
Kits [see page 12]

10
Dielectric Single Loose Tube
Fiber
Count

Unit Count
Units (Fibers/Unit)

1 (4)

1 (6)

1 (8)

12

1 (12)

Fiber
UL/NEC AMP NETCONNECT
Weight
Diameter
Type
Ratings
Part Number
kg/km (lb/kft) mm (in)
Singlemode
OSP
0-1664211-5
Multimode 50/125m
OSP
2-1664212-5
XG Multimode 50/125m OSP
8-1664212-5
Multimode 62.5/125m
OSP
1-1664213-5
Singlemode
OSP
0-1664214-5
Multimode 50/125m
OSP
2-1664215-5
XG Multimode 50/125m OSP
8-1664215-5
Multimode 62.5/125m
OSP
1-1664216-5
32 (22)
6.0 (0.24)
Singlemode
OSP
0-1664217-5
Multimode 50/125m
OSP
2-1664218-5
XG Multimode 50/125m OSP
8-1664218-5
Multimode 62.5/125m
OSP
1-1664219-5
Singlemode
OSP
0-1664220-5
Multimode 50/125m
OSP
2-1664221-5
XG Multimode 50/125m OSP
8-1664221-5
Multimode 62.5/125m
OSP
1-1664222-5

Tensile Load N (lbf)


Installation Long Term

Bending Radius mm (in)


Installation Long Term

1000 (220)

100 (3.9)

Note: Other cable designs (including hybrid) available. Call for more information.

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

890 (200)

60 (2.4)

FIBER OPTIC CABLE SUPPLEMENT

Dielectric Central
Strength Member
Water-Blocking Materials
Filled Buffer Tubes
Fibers
Water-Blocking Outer
Strength Members
Outer Jacket

OSP All-Dielectric Stranded Loose Tube


Fiber Optic Cable

Product Facts
n Suitable for
Intrabuilding links in a
campus environment
(ducted or direct burial)
Aerial links (when used
with a messenger strand)
Local loop and feeder
networks
Outdoor areas with
intermittent flooding
or moisture
Environments with
severe temperature
fluctuations
Drop or service cables
n High performance
singlemode and multimode
fibers meet all industry
performance standards
n TIA color-coded fibers in
TIA color-coded gel-filled
buffer tubes for easy
identification

n Dry water-blocking
technology
n Polyethylene UV-protected
jacket for harsh outdoor
environment
n Low friction jacket
for ease of pulling
through ducts
n All-dielectric construction
n Hybrid cables provide a
built-in upgrade for future
applications that will require
singlemode fibers
n Designed and tested
in accordance with TIA/EIA568-B,
Telcordia GR-20-CORE,
IEC 793-1/794-1,
ICEA-640 and
ISO/IEC 11801:2000
n Compatible with Splitter
Kits [see page 12]

FIBER OPTIC CABLE SUPPLEMENT

Outside Plant (OSP)


Dielectric, 24-144 Fiber

11
Dielectric Stranded Loose Tube
Fiber
Unit Count
Count Units (Fibers/Unit)
2 (12)
24
1 SM (12)
1 MM (12)
3 (12)
36
1 SM (12)
2 MM (12)
48

4 (12)

6 (12)
72
2 SM (12)
4 MM (12)
96

8 (12)

144

12 (12)

Fiber
UL/NECAMP NETCONNECT Weight
Type
Ratings
Part Number
kg/km (lb/kft)
Singlemode
OSP
0-1664190-5
Multimode 50/125m
OSP
2-1664191-5
XG Multimode 50/125m OSP
8-1664191-5
100 (68)
Multimode 62.5/125m
OSP
1-1664192-5
Hybrid
OSP
4-1664208-5
Singlemode-62.5/125m
Singlemode
OSP
0-1664193-5
Multimode 50/125m
OSP
2-1664194-5
XG Multimode 50/125m OSP
8-1664194-5
100(68)
Multimode 62.5/125m
OSP
1-1664195-5
Hybrid
OSP
4-1664209-5
Singlemode-62.5/125m
Singlemode
OSP
0-1664196-5
Multimode 50/125m
OSP
2-1664197-5
100(68)
XG Multimode 50/125m OSP
8-1664197-5
Multimode 62.5/125m
OSP
1-1664198-5
Singlemode
OSP
0-1664199-5
Multimode 50/125m
OSP
2-1664200-5
XG Multimode 50/125m OSP
8-1664200-5
130 (88)
Multimode 62.5/125m
OSP
1-1664201-5
Hybrid
OSP
4-1664210-5
Singlemode-62.5/125m
Singlemode
OSP
0-1664202-5
Multimode 50/125m
OSP
2-1664203-5
160 (110)
XG Multimode 50/125m OSP
8-1664203-5
Multimode 62.5/125m
OSP
1-1664204-5
Singlemode
OSP
0-1664205-5
Multimode 50/125m
OSP
2-1664206-5
250 (170)
XG Multimode 50/125m OSP
8-1664206-5
Multimode 62.5/125m
OSP
1-1664207-5

Diameter
mm (in)

Tensile Load N (lbf) Bending Radius mm (in)


Installation Long Term Installation Long Term

11.6 (0.46)

2700 (600)

890 (200)

232 (9.2)

116 (4.6)

11.6 (0.46)

2700 (600)

890 (200)

232 (9.2)

116 (4.6)

11.6 (0.46)

2700 (600)

890 (200)

232 (9.2)

116 (4.6)

12.6 (0.50)

2700 (600)

890 (200)

252 (10.0)

126 (5.0)

14.4 (0.57)

2700 (600)

890 (200)

288 (11.4)

144 (5.7)

18.0 (0.7)

2700 (600)

890 (200)

360 (14.2)

180 (7.1)

Note: Other cable designs (including hybrid) available. Call for more information.

For More Information, Call 1-800-553-0938


www.ampnetconnect.com

FIBER OPTIC CABLE SUPPLEMENT


FIBER OPTIC CABLE SUPPLEMENT

Product Facts
n Designed for use with
AMP NETCONNECT
Indoor/Outdoor and Outside
Plant Fiber Optic Cables
n One design for Single Loose Tube
Cables and another for Stranded
Loose Tube Cables

Buffer Tube Splitter Kits


Description
Stranded Loose Tube
Single Loose Tube

6-Fiber
12-Fiber
6-Fiber
12-Fiber

Part Number
1435018-1
1435019-1
1435020-1
1435021-1

12

In the U.S. 1-800-553-0938


Canada 905-475-6222
Mexico 525-729-0400
South and Central Americas 54-11-4733-2200
www.ampnetconnect.com
e-mail: networking.help@tycoelectronics.com
Copyright 2002 Tyco Electronics Corporation. All rights reserved.
AMP, AMP NETCONNECT, AMPTRAC, NETCONNECT and Tyco are trademarks. iTRACS is a trademark of iTRACS
Corporation. Other products, logos, and Company names mentioned herein may be trademarks of their respective owners.
1654200-pdf-DB-pdf-8/02 Printed in USA