OPTIFLUX 2000

Quick Start

Electromagnetic flow sensor

The documentation is only complete when used in combination with the relevant
documentation for the converter.

KROHNE 01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 2 Friday, January 22, 2010 12:12 PM

CONTENTS

OPTIFLUX 2000

1 Safety instructions

2 Installation

2.1
2.2
2.3
2.4
2.5

Scope of delivery............................................................................................................... 4
Nameplates ...................................................................................................................... 4
Storage ............................................................................................................................. 4
Transport .......................................................................................................................... 5
Installation conditions ...................................................................................................... 5

2.5.1 Inlet and outlet ........................................................................................................................ 5


2.5.2 Mounting position.................................................................................................................... 5
2.5.3 Flange deviation ...................................................................................................................... 6
2.5.4 T-section ................................................................................................................................. 6
2.5.5 Vibration .................................................................................................................................. 6
2.5.6 Magnetic field.......................................................................................................................... 7
2.5.7 Bends ...................................................................................................................................... 7
2.5.8 Open discharge ....................................................................................................................... 8
2.5.9 Control valve ........................................................................................................................... 8
2.5.10 Air venting ............................................................................................................................. 8
2.5.11 Pump ..................................................................................................................................... 9
2.5.12 Temperatures ....................................................................................................................... 9
2.5.13 Vacuum load........................................................................................................................ 10

2.6 Mounting ......................................................................................................................... 11


2.6.1 Torques and pressures......................................................................................................... 11

3 Electrical connections
3.1
3.2
3.3
3.4

14

Safety instructions.......................................................................................................... 14
Grounding ....................................................................................................................... 14
Virtual reference for IFC 300 (C, W and F version) ........................................................ 16
Connection diagram for measuring sensor, field housing ............................................ 17

4 Technical data

18

4.1 Dimensions and weight .................................................................................................. 18

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

Safety instructions

.book Page 3 Friday, January 22, 2010 12:12 PM

SAFETY INSTRUCTIONS 1

OPTIFLUX 2000

Warnings and symbols used


DANGER!
This information refers to the immediate danger when working with electricity.
DANGER!
These warnings must be observed without fail. Even partial disregard of this warning can lead to
serious health problems and even death. There is also the risk of seriously damaging the device
or parts of the operator's plant.
WARNING!
Disregarding this safety warning, even if only in part, poses the risk of serious health problems.
There is also the risk of damaging the device or parts of the operator's plant.
CAUTION!
Disregarding these instructions can result in damage to the device or to parts of the operator's
plant.
INFORMATION!
These instructions contain important information for the handling of the device.

HANDLING
This symbol designates all instructions for actions to be carried out by the operator in the
specified sequence.
i RESULT
This symbol refers to all important consequences of the previous actions.

Safety instructions for the operator


CAUTION!
Installation, assembly, start-up and maintenance may only be performed by appropriately
trained personnel. The regional occupational health and safety directives must always be
observed.
LEGAL NOTICE!
The responsibility as to the suitability and intended use of this device rests solely with the user.
The supplier assumes no responsibility in the event of improper use by the customer. Improper
installation and operation may lead to loss of warranty. In addition, the "Terms and Conditions of
Sale" apply. They appear on the back of the invoice and form the basis of the purchase contract.
INFORMATION!
Further information can be found on the supplied CD-ROM in the manual, on the data sheet,
in special manuals, certificates and on the manufacturer's website.
If you need to return the device to the manufacturer or supplier, please fill out the form
contained on the CD-ROM and send it with the device. Unfortunately, the manufacturer
cannot repair or inspect the device without the completed form.

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

Installation

.book Page 4 Friday, January 22, 2010 12:12 PM

2 INSTALLATION

OPTIFLUX 2000

2.1 Scope of delivery

1
2
3
4

Remote version
Compact version with IFC 300 signal converter
Compact version with IFC 100 (0) signal converter
Compact version with IFC 100 (45) signal converter

Figure 2-1: Scope of delivery


1
2
3
4
5
6

Ordered flowmeter
Product documentation
Factory calibration report
CD-ROM with product documentation
Grounding rings (optionally)
Cable (remote versions only)

2.2 Nameplates
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.

2.3 Storage
Store the device in a dry and dust-free location.
Avoid lasting direct exposure to the sun.
Store the device in its original packing.

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 5 Friday, January 22, 2010 12:12 PM

INSTALLATION 2

OPTIFLUX 2000

2.4 Transport

Figure 2-2: Transport

2.5 Installation conditions


2.5.1 Inlet and outlet

Figure 2-3: Recommended inlet and outlet sections


1 5 DN
2 2 DN

2.5.2 Mounting position

Figure 2-4: Mounting position

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

.book Page 6 Friday, January 22, 2010 12:12 PM

2 INSTALLATION

OPTIFLUX 2000

2.5.3 Flange deviation


CAUTION!
Max. permissible deviation of pipe flange faces:
Lmax - Lmin 0.5 mm / 0.02"

Figure 2-5: Flange deviation


1 Lmax
2 Lmin

2.5.4 T-section

Figure 2-6: Distance after T-sections


1 10 DN

2.5.5 Vibration

Figure 2-7: Avoid vibrations

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 7 Friday, January 22, 2010 12:12 PM

INSTALLATION 2

OPTIFLUX 2000

2.5.6 Magnetic field

Figure 2-8: Avoid magnetic fields

2.5.7 Bends

Figure 2-9: Installation in bending pipes

Figure 2-10: Installation in bending pipes

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

.book Page 8 Friday, January 22, 2010 12:12 PM

2 INSTALLATION

OPTIFLUX 2000

2.5.8 Open discharge

Figure 2-11: Installation before an open discharge

2.5.9 Control valve

Figure 2-12: Installation before control valve

2.5.10 Air venting

Figure 2-13: Air venting


1 5m
2 Air ventilation point

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 9 Friday, January 22, 2010 12:12 PM

INSTALLATION 2

OPTIFLUX 2000

2.5.11 Pump

Figure 2-14: Installation after pump

2.5.12 Temperatures
CAUTION!
Protect the device from direct sunlight.

Temperature range

Process [C]

Ambient [C]

Process [F]

Ambient [F]

min.

max.

min.

max.

min.

max.

min.

max.

Separate flow sensor

-5

80

-40

65

23

176

-40

149

Compact with IFC 300

-5

80

-40

65

23

176

-40

149

Compact with IFC 100

-5

80

-40

65

23

176

-40

149

Separate flow sensor

-5

90

-40

65

23

194

-40

149

Compact with IFC 300

-5

90

-40

65

23

194

-40

149

Compact with IFC 100

-5

90

-40

65

23

194

-40

149

Hardrubber

Polypropylene 1

1 Polypropylene available for DN25...150

Diameter

Minimum operating pressure absolute in mbar (abs) at process


temperature

[mm]

20C

40C

60C

80C

250

250

400

400

DN200...300

250

250

400

400

DN350...1000

500

500

600

600

DN1200...3000

600

600

750

750

Liner in Polypropylene
DN25...150
Liner in Hard rubber

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

.book Page 10 Friday, January 22, 2010 12:12 PM

2 INSTALLATION

OPTIFLUX 2000

Diameter

Minimum operating pressure absolute in psia at process temperature

[inches]

68F

104F

140F

176F

3.6

3.6

5.8

5.8

8...12"

3.6

3.6

5.8

5.8

14...40"

7.3

7.3

8.7

8.7

48...120"

8.7

8.7

10.9

10.9

Liner in Polypropylene
1...6"
Liner in Hard rubber

2.5.13 Vacuum load


Diameter

Minimum operating pressure absolute in mbar (abs) at process


temperature

[mm]

20C

40C

60C

80C

250

250

400

400

DN200...300

250

250

400

400

DN350...1000

500

500

600

600

DN1200...3000

600

600

750

750

Diameter

Minimum operating pressure absolute in psia at process temperature

[inches]

68F

Liner in Polypropylene
DN25...150
Liner in Hard rubber

104F

140F

176F

3.6

3.6

5.8

5.8

8...12"

3.6

3.6

5.8

5.8

14...40"

7.3

7.3

8.7

8.7

48...120"

8.7

8.7

10.9

10.9

Liner in Polypropylene
1...6"
Liner in Hard rubber

10

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 11 Friday, January 22, 2010 12:12 PM

INSTALLATION 2

OPTIFLUX 2000

2.6 Mounting
2.6.1 Torques and pressures

Figure 2-15: Tightening of bolts

Tightening of bolts
1 Step 1: Apply approx. 50% of max. torque given in table.
2 Step 2: Apply approx. 80% of max. torque given in table.
3 Step 3: Apply 100% of max. torque given in table.

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

11

.book Page 12 Friday, January 22, 2010 12:12 PM

2 INSTALLATION

OPTIFLUX 2000

Nominal DN
[mm]

12

Pressure
rating

Bolts

Max. torque [Nm]


Polypropylene

Hardrubber

25

PN 40

4 M 12

22

11

32

PN 40

4 M 16

37

19

40

PN 40

4 M 16

43

25

50

PN 40

4 M 16

55

31

65

PN 16

4 M 16

51

42

65

PN 40

8 M 16

38

21

80

PN 40

8 M 16

47

25

100

PN 16

8 M 16

39

30

125

PN 16

8 M 16

53

40

150

PN 16

8 M 20

68

47

200

PN 10

8 M 20

68

200

PN 16

12 M 20

45

250

PN 10

12 M 20

65

250

PN 16

12 M 24

78

300

PN 10

12 M 20

76

300

PN 16

12 M 24

105

350

PN 10

16 M 20

75

400

PN 10

16 M 24

104

450

PN 10

20 M 24

93

500

PN 10

20 M 24

107

600

PN 10

20 M 27

138

700

PN 10

20 M 27

163

800

PN 10

24 M 30

219

900

PN 10

28 M 30

205

1000

PN 10

28 M 35

261

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 13 Friday, January 22, 2010 12:12 PM

INSTALLATION 2

OPTIFLUX 2000

Nominal size
[inch]

Flange class
[lbs]

Bolts

Max. torque [Nm]


Polypropylene

Hardrubber

150

4 1/2"

6.7

4.4

1 1/2

150

4 1/2"

13

12

150

4 5/8"

24

23

150

4 5/8"

43

39

150

8 5/8"

34

31

150

8 3/4"

61

51

150

8 3/4"

69

10

150

12 7/8"

79

12

150

12 7/8"

104

14

150

12 1"

93

16

150

16 1"

91

18

150

16 1 1/8"

143

20

150

20 1 1/8"

127

24

150

20 1 1/4"

180

28

150

28 1 1/4"

161

32

150

28 1 1/2"

259

36

150

32 1 1/2"

269

40

150

36 1 1/2"

269

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

13

Electrical connections

.book Page 14 Friday, January 22, 2010 12:12 PM

3 ELECTRICAL CONNECTIONS

OPTIFLUX 2000

3.1 Safety instructions


DANGER!
All work on the electrical connections may only be carried out with the power disconnected. Take
note of the voltage data on the nameplate!
DANGER!
Observe the national regulations for electrical installations!
DANGER!
For devices used in hazardous areas, additional safety notes apply; please refer to the Ex
documentation.
WARNING!
Observe without fail the local occupational health and safety regulations. Any work done on the
electrical components of the measuring device may only be carried out by properly trained
specialists.
INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.

3.2 Grounding
DANGER!
The device must be grounded in accordance with regulations in order to protect personnel
against electric shocks.

Figure 3-1: Grounding


1 Metal pipelines, not internally coated. Grounding without grounding rings.
2 Metal pipelines with internal coating and non-conductive pipelines. Grounding with grounding rings.

14

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 15 Friday, January 22, 2010 12:12 PM

ELECTRICAL CONNECTIONS 3

OPTIFLUX 2000

Figure 3-2: Different types of grounding rings


1 Grounding ring number 1
2 Grounding ring number 2
3 Grounding ring number 3

Grounding ring number 1:


3 mm / 0.1" thick (tantalum: 0.5 mm / 0.1")

Grounding ring number 2:


3 mm / 0.1" thick
Prevents damage to the flanges during transport and installation
Especially for flow sensors with PTFE liner

Grounding ring number 3:


3 mm / 0.1" thick
With cylindrical neck (length 30 mm / 1.25" for DN10...150 / 3/8...6")
Prevents damage to the liner when abrasive liquids are used

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

15

.book Page 16 Friday, January 22, 2010 12:12 PM

3 ELECTRICAL CONNECTIONS

OPTIFLUX 2000

3.3 Virtual reference for IFC 300 (C, W and F version)

Figure 3-3: Virtual reference

Possible if:
DN10
Electrical conductivity 200 S/cm
Electrode cable max. 50m.

16

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 17 Friday, January 22, 2010 12:12 PM

OPTIFLUX 2000

ELECTRICAL CONNECTIONS 3

3.4 Connection diagram for measuring sensor, field housing


DANGER!
The device must be grounded in accordance with regulations in order to protect personnel
against electric shocks.
If a shielded field current cable is used, the shield must NOT be connected.
The outer shield of signal cable A or B in the signal converter housing is connected via the
strain relief terminal.
Bending radius of signal and field current cable: 50 mm / 2"
The following illustration is schematic. The positions of the electrical connection terminals
may vary depending on the housing version.

Figure 3-4: Connection diagram for measuring sensor, field housing


1
2
3
4
5
6

Electrical terminal compartment in housing of the signal converter for signal and field current cable.
Signal cable A
Signal cable B
Field current cable C
Connection box of measuring sensor
Functional ground FE

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

17

Technical data

.book Page 18 Friday, January 22, 2010 12:12 PM

4 TECHNICAL DATA

OPTIFLUX 2000

4.1 Dimensions and weight


Remote version

a = 77 mm / 3.1"
b = 139 mm / 5.5" 1
c = 106 mm / 4.2"
Total height = H + a

Compact version with


IFC 300

a = 155 mm / 6.1"
b = 230 mm / 9.1" 1
c = 260 mm / 10.2"
Total height = H + a

Compact version with


IFC 100 (0)
(0 )

a = 82 mm / 3.2"
b = 161 mm / 6.3"
c = 257 mm / 10.1" 1
Total height = H + a

Compact version with


IFC 100 (45)
(45 )

a = 186 mm / 7.3"
b = 161 mm / 6.3"
c = 184 mm / 2.7" 1
Total height = H + a

1 The value may vary depending on the used cable glands.

INFORMATION!
All data given in the following tables are based on standard versions of the sensor only.
Especially for smaller nominal sizes of the sensor, the converter can be bigger than the
sensor.
Note that for other pressure ratings than mentioned, the dimensions may be different.
For full information on converter dimensions see relevant documentation.

18

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 19 Friday, January 22, 2010 12:12 PM

TECHNICAL DATA 4

OPTIFLUX 2000

EN 1092-1
Nominal size
DN

Dimensions [mm]

PN [bar]

L
DIN

Approx.
weight [kg]

ISO

25

40

150

200

140

115

32

40

150

200

157

140

40

40

150

200

166

150

50

40

200

200

186

165

11

65

16

200

200

200

185

80

40

200

200

209

200

14

100

16

250

250

237

220

15

125

16

250

250

266

250

19

150

16

300

300

300

285

27

200

10

350

350

361

340

34

250

10

400

450

408

395

48

300

10

500

500

458

445

58

350

10

500

550

510

505

78

400

10

600

600

568

565

101

450

10

600

618

615

111

500

10

600

671

670

130

600

10

600

781

780

165

700

10

700

898

895

248

800

10

800

1012

1015

331

900

10

900

1114

1115

430

1000

10

1000

1225

1230

507

1200

1200

1417

1405

555

1400

1400

1619

1630

765

1600

1600

1819

1830

1035

1800

1800

2027

2045

1470

2000

2000

2259

2265

1860

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

19

.book Page 20 Friday, January 22, 2010 12:12 PM

4 TECHNICAL DATA

OPTIFLUX 2000

150 lbs flanges


Nominal size
ASME

Dimensions [mm]

PN [psi]

Approx. weight
[kg]

1"

284

150

137

108.0

1"

284

150

155

127.0

10

2"

284

200

179

152.0

13

3"

284

200

204

190.5

17

4"

284

250

241

228.6

23

5"

284

250

268

254.0

27

6"

284

300

297

279.4

34

8"

284

350

362

342.9

43

10"

284

400

414

406.4

65

12"

284

500

477

482.6

94

14"

284

700

525

533.4

129

16"

284

800

583

596.9

165

18"

284

800

628

635

186

20"

284

800

685

698.5

223

24"

284

800

797

812.8

306

CAUTION!
Pressures at 20C / 68F.
For higher temperatures, the pressure and temperature ratings are as per ASME B16.5 (up to
24") or ASME B16.47 (>24").
Dimensions for other sizes on request.

20

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 21 Friday, January 22, 2010 12:12 PM

TECHNICAL DATA 4

OPTIFLUX 2000

Nominal size
ASME

Dimensions [inches]

PN [psi]

Approx. weight
[lbs]

1"

284

5.91

5.39

4.25

18

1"

284

5.91

6.10

5.00

22

2"

284

7.87

7.05

5.98

29

3"

284

7.87

8.03

7.50

37

4"

284

9.84

9.49

9.00

51

5"

284

9.84

10.55

10

60

6"

284

11.81

11.69

11

75

8"

284

13.78

14.25

13.5

95

10"

284

15.75

16.3

16.0

143

12"

284

19.69

18.78

19.0

207

14"

284

27.56

20.67

21.0

284

16"

284

31.50

22.95

23.5

364

18"

284

31.50

24.72

25.0

410

20"

284

31.50

26.97

27.5

492

24"

284

31.50

31.38

32.0

675

CAUTION!
Pressures at 20C / 68F.
For higher temperatures, the pressure and temperature ratings are as per ASME B16.5 (up to
24") or ASME B16.47 (>24").
Dimensions for other sizes on request.

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

21

.book Page 22 Friday, January 22, 2010 12:12 PM

4 TECHNICAL DATA

OPTIFLUX 2000

300 lbs flanges


Nominal size
ASME

Dimensions [mm]

PN [psi]

Approx. weight
[kg]

1"

741

150

145

123.8

1"

741

200

169

155.6

2"

741

250

186

165.1

13

3"

741

250

214

209.6

17

4"

741

300

254

254.0

23

6"

741

320

316

317.5

36

8"

741

400

382

381.0

71

10"

741

500

433

444.5

112

12"

741

600

508

520.7

170

14"

741

700

550

584.2

215

16"

741

800

609

647.7

290

20"

741

800

723

774.7

425

24"

741

800

848

914.4

610

CAUTION!
Pressures at 20C / 68F.
For higher temperatures, the pressure and temperature ratings are as per ASME B16.5 (up to
24") or ASME B16.47 (>24").
Dimensions for other sizes on request.

22

www.krohne.com

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

.book Page 23 Friday, January 22, 2010 12:12 PM

TECHNICAL DATA 4

OPTIFLUX 2000

Nominal size
ASME

Dimensions [inches]

PN [psi]

Approx. weight
[lbs]

1"

741

5.91

5.71

4.87

18

1"

741

7.87

6.65

6.13

20

2"

741

9.84

7.32

6.50

29

3"

741

9.84

8.43

8.25

37

4"

741

11.81

10.00

10.00

51

6"

741

12.60

12.44

12.50

79

8"

741

15.75

15.04

15.0

157

10"

741

19.69

17.05

17.5

247

12"

741

23.62

20.00

20.5

375

14"

741

27.56

21.65

23.0

474

16"

741

31.50

23.98

25.5

639

20"

741

31.50

28.46

30.5

937

24"

741

31.50

33.39

36.0

1345

CAUTION!
Pressures at 20C / 68F.
For higher temperatures, the pressure and temperature ratings are as per ASME B16.5 (up to
24") or ASME B16.47 (>24").
Dimensions for other sizes on request.

01/2010 - 7309842200 - QS OPTIFLUX 2000 en

www.krohne.com

23

.book Page 24 Friday, January 22, 2010 12:12 PM

KROHNE 01/2010 - 7309842200 - QS OPTIFLUX 2000 en - Subject to change without notice.

KROHNE product overview

Electromagnetic flowmeters
Variable area flowmeters
Ultrasonic flowmeters
Mass flowmeters
Vortex flowmeters
Flow controllers
Level meters
Temperature meters
Pressure meters
Analysis products
Measuring systems for the oil and gas industry
Measuring systems for sea-going tankers

Head Office KROHNE Messtechnik GmbH


Ludwig-Krohne-Str. 5
D-47058 Duisburg (Germany)
Tel.:+49 (0)203 301 0
Fax:+49 (0)203 301 10389
info@krohne.de
The current list of all KROHNE contacts and addresses can be found at:
www.krohne.com

You might also like