Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

Cover_MAEN824E.

fm Page 1 Monday, March 9, 2009 2:17 PM

H-T60
Installation and Operation Manual
MAEN824E, 2009-03 English
Foreword

H-T60 Installation and Operation Manual

Foreword
H-T60 is a Human Machine Interface (HMIs) with a 5.7" STN Liquid Crystal
Display, and is water- and dust-resistant according to IP65/NEMA4X (indoor use
only).
H-T60 is CE-marked and meets your need to be highly transient-resistant while
in operation.
Also, its compact design makes connections with other machinery more flexible,
thus achieving the optimal performance of your machines.
H-Designer is used to design applications of H-T60; it is reliable, user-friendly
and compatible with many models.

© Beijer Electronics AB, MAEN824E, 2009-03


Please read the entire installation manual prior to installing and using this equipment. Only qualified person-
nel may install, operate or repair this equipment. Beijer Electronics AB is not responsible for modified,
altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire
the appropriate knowledge to use the equipment properly in their specific applications. Persons responsible
for the application and the equipment must themselves ensure that each application is in
compliance with all relevant requirements, standards and legislation in respect to configuration and safety.
Only parts and accessories manufactured according to specifications set by Beijer Electronics AB may be
used.
BEIJER ELECTRONICS AB SHALL NOT BE LIABLE TO ANYONE FOR ANY DIRECT,
INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM
THE INSTALLATION, USE OR REPAIR OF THIS EQUIPMENT, WHETHER ARISING IN TORT,
CONTRACT, OR OTHERWISE. BUYER'S SOLE REMEDY SHALL BE THE REPAIR, REPLACE-
MENT, OR REFUND OF PURCHASE PRICE, AND THE CHOICE OF THE APPLICABLE REM-
EDY SHALL BE AT THE SOLE DISCRETION OF BEIJER ELECTRONICS AB.

Beijer Electronics, MAEN824E


Contents

Contents
1 Safety Precautions................................................................................... 5

2 Installation.............................................................................................. 7
2.1 Package Contents......................................................................... 7

3 Product Specifications............................................................................. 8
3.1 Description of Parts ................................................................... 12
3.2 External and Cut-out Dimensions .............................................13
3.3 Mounting Procedure .................................................................. 13
3.4 Grounding .................................................................................14
3.5 Power Supply and Wiring .......................................................... 15

4 Dip Switches......................................................................................... 16

5 Communication Ports........................................................................... 17

6 LCD Contrast Adjustment ................................................................... 18

7 Operation ............................................................................................. 19
7.1 Self Test ..................................................................................... 19
7.2 System Menu ............................................................................. 20
7.3 Key Pad...................................................................................... 21
7.4 Bench and Function Tests .......................................................... 22
7.5 Setting Parameters...................................................................... 22
7.6 Downloading an Application ..................................................... 23
7.7 Uploading an Application .......................................................... 24
7.8 Uploading/Downloading a Recipe .............................................25
7.9 Copying an Application ............................................................. 26
7.10 Passwords................................................................................... 27

Beijer Electronics, MAEN824E


Contents

Beijer Electronics, MAEN824E


Safety Precautions

1 Safety Precautions
Both the installer and the owner and/or operator of the operator terminal must
read and understand this installation manual.
General
– Only qualified personnel may install or operate the operator terminal.
– The operator terminal must be installed according to the installation instruc-
tions.
– The operator terminal is designed for stationary installation on a plane surface,
where the following conditions are fulfilled:
• no high explosive risks
• no strong magnetic fields
• no direct sunlight
• no large, sudden temperature changes
• for use in Pollution Degree 2 Environment
• for use on the flat surface of Types 1 and 4X (indoor use only) enclosures
– Never allow fluids, metal filings or wiring debris to enter any openings in the
operator terminal. This may cause fire or electrical shock.
– The operator terminal fulfills the requirements of article 4 of EMC directive
2004/108/EC.
– Storing the operator terminal where the temperature is lower/higher than
recommended in this manual can cause the LCD display liquid to congeal/
become isotopic.
– The LCD display liquid contains a powerful irritant. In case of skin contact,
wash immediately with plenty of water. In case of eye contact, hold the eye
open, flush with plenty of water and get medical attention.
– The supplier is not responsible for modified, altered or reconstructed equip-
ment.
– Use only parts and accessories manufactured according to specifications of the
supplier.
– Peripheral equipment must be appropriate for the application and location.
– The figures in this manual serves an illustrative purpose. Because of the many
variables associated with any particular installation, the supplier cannot as-
sume responsibility for actual use based on the figures.
– The supplier neither guarantees that the operator terminal is suitable for your
particular application, nor assumes responsibility for your product design, in-
stallation or operation.
Beijer Electronics, MAEN824E 5
Safety Precautions

Power source
– The operator terminal is equipped with a 24 V DC input. Supply power other
than 24 V DC ± 15% will severely damage the operator terminal. Thus, check
the power supply supporting the DC power regularly.
Grounding
– Without grounding, the operator terminal may be severely affected by excess
noise. Make sure that the grounding is done properly from the power connec-
tor at the rear side of the operator terminal. When power is connected, make
sure that the wire is grounded.
– Use a cable of at least 2 mm2 (AWG 14) to ground the operator terminal.
Ground resistance must be less than 100 Ω (class3). Note that the ground
cable must not be connected to the same ground point as the power circuit.
Installation
– Communication cables must be separated from power cables for operational
circuits. Only use shielded cables to avoid unpredictable problems.
During Use
– Emergency stop and other safety functions may not be controlled from the
operator terminal.
– Do not use too much force or sharp objects when touching the keys, display
etc.
Service and Maintenance
– Only qualified personnel should carry out repairs.
– The agreed warranty applies.
– Before carrying out any cleaning or maintenance operations, disconnect the
equipment from the electrical supply.
– Clean the display and surrounding front cover with a soft cloth and mild
detergent.
– Replacing the battery incorrectly may result in explosion. Only use batteries
recommended by the supplier.
Dismantling and Scrapping
– The operator terminal or parts thereof shall be recycled according to local
regulations.
– The following components contain substances that might be hazardous to
health and the environment: lithium battery, electrolytic capacitor and
display.

6 Beijer Electronics, MAEN824E


Installation

2 Installation
2.1 Package Contents
The following parts are found in the box:
– Operator terminal H-T60

– 6 installation fasteners

– Power connector (connected to the 24 V DC power input)

– Installation and operation manual (MAEN824E)

Beijer Electronics, MAEN824E 7


Product Specifications

3 Product Specifications
H-T60t Models:

Parameter H-T60t-Ne H-T60t-Pe H-T60t-S


Front panel, W x H x D 195.0 x 145.0 x 6.0 mm
Mounting depth 59.1 mm
Cut-out dimensions 185.8 x 135.8 mm
Front panel seal IP 65/NEMA 4X (indoor use only)
Keypad specifications 1 “Menu”-key and 5 user-defined function keys (F1-F5).
Pressure: 350 ± 50 gf operating force.
Lifetime: over 1,000,000 activations.
Weight 0.81 kg
COM 1 9-pin female connector: RS232/RS485
COM 2 25-pin female connector: RS232/RS422/RS485
USB port Yes -
CF card port Yes -
Ethernet Yes -
Flash ROM 4 MB
RAM 512 KB
CPU 32-bit RISC
Battery backed memory 512 KB
Data/Recipe 512 KB -
Real time clock Yes (with rechargeable lithium battery)
Display Color TFT LCD, 64K colors, 320 x 240 Color TFT LCD,
pixels. 256 colors, 320 x
240 pixels.
LED backlight lifetime: approximately 30,000 h at 25 °C
Active area of display, 117.2 x 88.4 mm.
WxH 40 x 30 characters of 8 x 8 size can be displayed.
Display adjustment -
Touch screen Analog
Power supply 24 V DC ± 15%. Less than 20 W.

8 Beijer Electronics, MAEN824E


Product Specifications

Parameter H-T60t-Ne H-T60t-Pe H-T60t-S


Ambient temperature 0 ° to +50 °C
Storage temperature -10 ° to +60 °C
Ambient humidity 20 - 90% RH non-condensed
Vibration endurance 0.5 mm displacement, 10-55 Hz, 2 hours per X-, Y- and Z-
axis directions
Shock endurance 10 G, 11 ms 3 times in each direction of X-, Y- and Z-axes
CE EN61000-6-4,EN61000-6-2
Cooling Natural cooling

Beijer Electronics, MAEN824E 9


Product Specifications

H-T60b Models:

Parameter H-T60b-Ne H-T60b-Pe H-T60b-S


Front panel, W x H x D 195.0 x 145.0 x 6.0 mm
Mounting depth 59.1 mm
Cut-out dimensions 185.8 x 135.8 mm
Front panel seal IP 65/NEMA 4X (indoor use only)
Keypad specifications 1 “Menu”-key and 5 user-defined function keys (F1-F5).
Pressure: 350 ± 50 gf operating force.
Lifetime: over 1,000,000 activations.
Weight 0.81 kg
COM 1 9-pin female connector: RS232/RS485
COM2 25-pin female connector: RS232/RS422/RS485
USB port Yes -
CF card port Yes -
Ethernet Yes -
Flash ROM 4 MB
RAM 512 KB
CPU 32-bit RISC
Battery backed memory 512 KB
Data/Recipe 512 KB -
Real time clock Yes (with rechargeable lithium battery)
Display Mono STN LCD, 16 shades of blue, 320 x 240 pixels,
CCFT backlight lifetime: approximately 50,000 h at 25 °C
Active area of display, 117.2 x 88.4 mm.
WxH 40 x 30 characters of 8 x 8 size can be displayed.
Display adjustment Via touch screen
Touch screen Analog
Power supply 24 V DC ± 15%. Less than 20 W.
Ambient temperature 0 ° to +50 °C
Storage temperature -10 ° to +60 °C
Ambient humidity 20 - 90% RH non-condensed

10 Beijer Electronics, MAEN824E


Product Specifications

Parameter H-T60b-Ne H-T60b-Pe H-T60b-S


Vibration endurance 0.5 mm displacement, 10-55 Hz, 2 hours per X-, Y- and Z-
axis directions
Shock endurance 10 G, 11 ms 3 times in each direction of X-, Y- and Z-axes
CE EN61000-6-4, EN61000-6-2
Cooling Natural cooling

Beijer Electronics, MAEN824E 11


Product Specifications

3.1 Description of Parts


Front
Fixture mounting holes

Function keys

Power lamp
Communication lamps
Network lamp

Display

Back
Battery cover
CF card connection
DC power input
DIP switches (1-10)

USB port for transmission


USB port for memory stick

Network connection

COM1: RS232/RS485
COM2: RS232/RS422/RS485

12 Beijer Electronics, MAEN824E


Product Specifications

3.2 External and Cut-out Dimensions


Unit: mm 185.8±0.5

185

135.8±0.5
46.6

59.1

195
6.0
145

135

3.3 Mounting Procedure


1. Cut out the control front panel to match the dimensions (mm) below.

Beijer Electronics, MAEN824E 13


Product Specifications

2. Mount the operator terminal into the cut-out. Insert the fixtures to the
holes on the unit and fasten the screws into the front panel. Do not tighten
the screws with too much or uneven force, or it may cause the deformation
of the operator terminal.
STEP 1 STEP 2 STEP 3

Torque: 0.6 ~ 0.7 Nm (5.31-6.2 lb-in)

3. The operator terminal is to be installed within the angle of 0 to 135 ° as


shown below.

3.4 Grounding
To make sure that the operator terminal works properly and to prevent it from
radiating radio frequency noise, it must be connected to the earth ground.

14 Beijer Electronics, MAEN824E


Product Specifications

3.5 Power Supply and Wiring


H-T60 must use the power supply with 24 V DC and the power consumption
is 20W.

Warning:
To avoid an electrical shock, be sure to switch off the power before connecting the
communication/download cable to the operator terminal.

Perform the following steps to wire the power connector:


1. Unplug the power connector and unscrew the screws.
2. Strip approximately 7-8 mm of insulation. Insert the wire all the way into
the power connector and then turn the screws tight.
3. Plug in the connector to the power input of the operator terminal.

Note:
The power connector is already plugged into the power input of operator terminal
when the package is first opened.

Use copper conductors only, 60/75 °C.

Wire Gauge Stripped


Type Torque
(AWG) Length
Solid 28-12 7-8 mm 4.5 lb-in
-
+

FG
DC 24V
Stranded 30-12 7-8 mm 4.5 lb-in

Beijer Electronics, MAEN824E 15


Dip Switches

4 Dip Switches
Dip switch Function
SW1 Reserved
SW2 Reserved
SW3 SW4 Operation Mode
ON ON Runs user application
ON OFF Runs burn-in test program
OFF ON Updates BIOS
OFF OFF Runs bench test program
SW5 Communication Parameters
ON The operator terminal uses the communication parameters
defined on the operator terminal’s configuration screen for
controller communication.
OFF The operator terminal uses the communication parameters
defined in H-Designer for controller communication.
SW6 Password
ON The operator terminal asks the operator to enter a password
after power-on self-test.
OFF No password is required to start the operator terminal.
SW7 System Menu
ON The operator terminal displays the system menu.
OFF The operator terminal runs user application without displaying
the system menu.
SW8 Default User Level
ON The default user level is set to 1 if the operator terminal
requires no password to start its operation.
OFF The default user level is set to 9 if the operator terminal
requires no password to start its operation.
SW9 Reserved
SW10 COM2 Port
ON For RS485, this switch has to be set ON.
For RS422, this switch has to be set OFF.
OFF

16 Beijer Electronics, MAEN824E


Communication Ports

5 Communication Ports
COM1, a 9-pin female connector, is used to connect the operator terminal to a
controller via RS232 or RS485.
COM2, a 25-pin female connector, is used to connect the operator terminal to
a controller via RS232, RS422 or RS485.
Note:
Make sure that the connection is in accordance with the setting of the dip switches,
for example RS485 corresponds to SW10 = ON. See section 4 Dip Switches.

COM 2
13 12 11 10 9 8 7 6 5 4 3 2 1

25 24 23 22 21 20 19 18 17 16 15 14

Pin Function Pin Function Pin Function


1 RS485+ 1 N/A 14 RS422 TX+
(RS485+)
2 RS232 RXD 2 RS232 TXD 15 RS422 TX-
(RS485-)
3 RS232 TXD 3 RS232 RXD 16 RS422 RX+
4 N/A 4 RS232 RTS 17 RS422 RX-
5 Signal ground 5 RS232 CTS 18
6 RS485- 6 N/A 19
7 RS232 RTS 7 Signal ground 20
8 RS232 CTS 8 Optional; 21 N/A
+5V@100mA output
9 Optional; 9 22
+5V@100mA output
10 N/A 23 RS422 RTS+
11 24 RS422 RTS-
12 RS422 CTS+ 25 N/A
13 RS422 CTS-

Beijer Electronics, MAEN824E 17


LCD Contrast Adjustment

6 LCD Contrast Adjustment


Only available for H-T60b-S, H-T60b-Pe and H-T60b-Ne.
The LCD contrast can be adjusted via the touch screen using the system menu
command F4 - Set, and performing the following steps:
1. Touch the upper-left and lower-right corners of the screen.
2. Follow the route on the screen.
3. Touch the square on the center of the screen to complete the task.
Note:
When using the F4 -Set command all RAM data will be cleared.

See also section 7.2 System Menu.

18 Beijer Electronics, MAEN824E


Operation

7 Operation
7.1 Self Test
Once the operator terminal is turned on, it will automatically execute a self-test
to check its hardware. The results of the self-test will be displayed on the screen
according to the following picture.

If any of tests does not pass the self-test, it will be noted with “Failed” next to
the test item. Additionally, the message “Error! Press screen to continue” will be
displayed at the bottom of the screen.
If the power to the operator terminal or the PC was interrupted while download-
ing, Firmware checksum or Application checksum will not pass the self-test, in-
dicated by “Failed” in the self-test results after power is restored. If this happens,
the user can simply follow the download procedure to re-download the applica-
tion or data. After downloading again, all items should pass the self-test.

Note:
When using the operator terminal for the first time, remember to reset the real
time clock (RTC).

Beijer Electronics, MAEN824E 19


Operation

7.2 System Menu


Set the dip switch SW7 = ON. After the self-test, the system menu of the oper-
ator terminal is displayed on the screen:

The functions of the commands are briefly explained below:

System menu
Function
command
Link The operator terminal is connected.
F2 - Confg Sets up the internal time clock and communication parameters
in the operator terminal. All the settings has to be made for
the operator terminal to work properly.
Use , , and to move to desired field; + and - to set
the value of the field.
F3 - Copy Copies application data to another H-T60.
F4 - Set Adjusts touch panel LCD contrast and clears data RAM.
See also section 6 LCD Contrast Adjustment.
Note: The contrast of the H-T60t models cannot be adjusted.
F5 - Run Runs the application.

20 Beijer Electronics, MAEN824E


Operation

7.3 Key Pad


The six keys on the H-T60 include one menu key and five functional keys (F1-
F5), described below. Press the menu key to slide out the innovative slide-out
menu.
The functional keys can also be defined in H-Designer and used as “Quick-
buttons”, for example, to set an ON/OFF value, to change a screen etc.
For further information about the slide-out menu, please see the H-Designer
User’s Manual.

Menu key
Functional keys F1-F5

When a key is pressed, the operator terminal will make a “beep” sound to signal
that a command is pressed. The default setting, a 200 ms beep, can be config-
ured in H-Designer.

Beijer Electronics, MAEN824E 21


Operation

7.4 Bench and Function Tests


Set dip switches SW3 and SW4 = OFF to be able to run the bench and function
tests for the H-T60. Turn on the operator terminal to display the following
screen:

The bench test performs an overall hardware test, and the function test lets the
user select which item to be tested.

Note:
The bench test will clear the application data of the operator terminal.

7.5 Setting Parameters


There are two ways to configure working parameters; to set parameters in the
operator terminal or in H-Designer.
To set parameters in the operator terminal, select F2 - Confg in the system
menu.

Note:
Remember to set dip switch SW5 = ON if parameters are set in the operator
terminal.

To set parameters in H-Designer, select Application/Workstation Setup. Select


the Connection tab to set communication parameters.

Note:
Remember to set dip switch SW5 = OFF if parameters are set in H-Designer.

22 Beijer Electronics, MAEN824E


Operation

7.6 Downloading an Application


Connect the RS232 port on the PC to the COM1 port on the H-T60 using a
WPC-P8-42 cable, or to the COM2 port using a WPC-P8-41 cable.
The connection can also be made according to the illustration below, where the
left-hand illustration applies to COM1, and the right-hand one to COM2:
9-pin male 9-pin female 25-pin male 9-pin female
RXD 2 2 RD TXD 2 2 RD
TXD 3 3 SD RXD 3 3 SD
GND 5 5 SG GND 7 5 SG
RTS 7 1 CD RTS 4 1 CD
CTS 8 4 DTR CTS 5 4 DTR
6 DSR 6 DSR
7 RTS 7 RTS
8 CTS 8 CTS

Warning:
To avoid an electrical shock, be sure to switch off the power before connecting the
download cable to the operator terminal.

Set the dip switch SW7 = ON. After the self-test, the system menu will be
displayed on the screen and the operator terminal is ready to download the
application.
Start H-Designer and open the application file to be downloaded. Make sure
that the communication parameters are correctly configured. Also remember to
compile the file before downloading it. The file has to be compiled every time a
change has been made in the file before downloading it.
Then select Application/Download Firmware/Application in H-Designer if it
is a first time to download the application to the operator terminal; otherwise,
select Application/Download Application. The following appears on the screen
while the operator terminal is downloading:

Beijer Electronics, MAEN824E 23


Operation

7.7 Uploading an Application


An application can also be uploaded from the operator terminal to the PC.
Thus, a user can save an application as a *.V6F file in H-Designer for future use.
Warning:
To avoid an electrical shock, be sure to switch off the power before connecting the
communication cable to the operator terminal.

Make sure that the operator terminal and the PC are connected according to
section 7.6 Downloading an Application. Set the dip switch SW7 = ON. After
the self-test, the system menu will be displayed on the screen and the operator
terminal is ready to upload the application.
Also make sure that communication parameters are correctly configured. Select
File/Upload Application in H-Designer and the Save As dialog box will appear
on the screen. Enter the name of a firmware file (*.AF6) to save. Click Save.
Then the operator terminal will prompt for a password: enter the password set
in H-Designer from Application/Workstation Setup. Once the correct pass-
word is entered, the operator terminal starts to upload the application to the PC.
For information about setting a password, please see section 7.10 Passwords.
While the operator terminal is uploading, the following is displayed:

After uploading, select File/Reconstruct Source in H-Designer to display the


Open dialog. Open the uploaded application file (*.C64 or *.AA6). The appli-
cation screen will be displayed on the PC monitor. Finally, select File/Save As to
save the application as a *.V6F file. Thus a source file can serve the purposes of
maintenance and modification.
Note:
When uploading for the first time, make sure to first run the application once, or
else the upload function will not work.

24 Beijer Electronics, MAEN824E


Operation

7.8 Uploading/Downloading a Recipe


Set the dip switch SW7 = ON. After the self-test, the system menu will be
displayed on the screen and the operator terminal is ready to upload/download
a recipe.

Uploading a Recipe
Select File/Upload Recipes in H-Designer and the Save As dialog box will
appear on the screen. Enter the name of a recipe file (*.RCP) to save. Click Save.
While the operator terminal is uploading the recipe, Uploading recipes is dis-
played on the screen.

Downloading a Recipe
Open an application file with the recipe to be downloaded in H-Designer. Select
File/Download Recipes to display the Open dialog. Enter the name of the rec-
ipe file (*.RCP) and click Open. While the operator terminal is downloading the
recipe, Downloading recipes is displayed on the screen.:

After the download is finished, select F5 - Run to run the application.


Remember to define the length and the number of recipes in the application.
Also remember to upload the format of recipes from the operator terminal be-
fore starting to edit a new set of recipe data in the PC.
For further information about creating/editing recipes, please see the corre-
sponding chapter in the H-Designer User’s Manual.

Beijer Electronics, MAEN824E 25


Operation

7.9 Copying an Application


To copy an application from one H-T60 to another H-T60, select F3 - Copy
from the system menu. Set the dip switch SW7 = ON and connect the two op-
erator terminals with a download cable. After the self-test, the system menu will
be displayed on the screen.
Select F3 - Copy in the system menu from the operator terminal with the appli-
cation to be copied. The operator terminal will prompt for a password: enter the
password set in H-Designer from Application/Workstation Setup. Once the
correct password is entered, the H-T60 starts to copy the application to the
other H-T60.
For information about setting a password, please see section 7.10 Passwords.
The following appears on the screens during the copying:

Note:
When copying for the first time, make sure to first run the application once, or
else the copy function will not work.

26 Beijer Electronics, MAEN824E


Operation

7.10 Passwords
Scenario 1: Requiring a password to start the operator terminal
If the dip switch SW6 = ON, the user needs to enter a password to start the
operator terminal. For this purpose, the designer can use the object Action
Button in H-Designer to create a button which displays the password table on
the operator terminal display. A user with the right to access the table can register
passwords and user levels in the table, shown below.

In the illustration below, the button is an action button used to display the
password table. When the button is selected the password table is displayed on
the screen for a user with the right to access the table.

How to configure an Action Button is described in the H-Designer User’s


Manual.
After registering passwords and user levels, set the dip switch SW6 = ON (i.e.
password required). Restart the operator terminal and after the self-test the user
will be prompted to enter a password in order to run the operator terminal.

Beijer Electronics, MAEN824E 27


Operation

The operator terminal will determine the user level from the entered password.
For instance, if the level of the password entered by the user is 1, then the oper-
ator terminal will set the user level to1; if the level of the password entered by
the user is 2, then the operator terminal will set the user level to 2. User level 1
has the highest privilege and User level 9 has the lowest.

Note:
Only users of User Level 1 has the right of access to the password table.

Scenario 2: Re-entering a password


The object Action Button in H-Designer also allows the designer to create a but-
ton which asks the user to re-enter a password.
For example, by pressing the button the password keypad will be displayed
to prompt the user to enter a password. After entering the password, the opera-
tor terminal will update the user level according to the most recent password
which has been entered. Therefore, this button can be applied to raise or drop
one’s privileges while the operator terminal is in operation.

How to configure an Action Button is described in the H-Designer User’s


Manual.

28 Beijer Electronics, MAEN824E


Operation

Scenario 3: Password-protecting a button in the operator terminal


The designer can create a button which is protected by a password for execution.
For example, a Goto Screen button can be designed with a high level of security;
which means that a password with a high level of privilege is required in order
to open the other screen. As the button is selected and the current user has a low-
er privilege than has been set for the button, the operator terminal will prompt
the user for a password. The user will need a password with at least the level of
privilege that has been set for the button. This function can restrict users to ac-
cess to certain parts of the application.

Scenario 4: Requiring a password to copy or upload application


When selecting F3 - Copy in the system menu or File/Upload Application in
H-Designer, the operator terminal will prompt for a password. The user will
need to enter the correct password to copy an application from one H-T60 to
another. Note that setting this password is different from the passwords set in
Scenarios 1-3. To set this password, select Application/Workstation Setup in H-
Designer. Under the Password tab, the designer is able to set the password.

Beijer Electronics, MAEN824E 29


Cover_MAEN824E.fm Page 2 Monday, March 9, 2009 2:17 PM

Head Office Subsidiaries


Sweden Germany China
Beijer Electronics Products AB Elektronik-Systeme Lauer GmbH & Co. KG Beijer Electronics Co. Ltd
Box 426 Kelterstraße 59 Room 201, Buildning B, No. 1618,
201 24 Malmö, SWEDEN 72669 Unterensingen, GERMANY Yishan Road, Shanghai 201103, CHINA
Tel: +46 40 35 86 00 Tel.: +49 70 22/96 60-101 Tel: +86 21 6145 0400
Fax: +46 40 93 23 01 Fax: +49 70 22/96 60-103 Fax: +86 21 6145 0499
info@beijerelectronics.com info@systeme-lauer.de info@beijerelectronics.cn

USA Taiwan
Beijer Electronics Inc. Hitech Electronics Corp.
939 N. Plum Grove Road, Suite F 7 & 8 F, No. 108 Min-Quan Road
Schaumburg, IL 601 73, USA Shin-Tien, Taipei Shien, TAIWAN,
Tel: +1 847 619 6068 R.O.C. 231
Fax: +1 847 619 6674 Tel: +886-2-2218-3600
info.usa@beijerelectronics.com Fax: +886-2-2218-9547
hmi@hitech-lcd.com.tw

You might also like