Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

f3n2c PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

www.emersonct.

com
800-893-2321

Focus 3

Rugged and Robust


The Focus 3 is a single-phase analog drive for DC
motors with power ranges from 1/4 to 5 hp. Years of
proven engineering design matched with surface mount
technology make this newest Focus product rugged and
reliable.
Customer feedback guided the development of the
Focus 3. Many features that were typically available only
as options are now standard, expanding its versatility
and simplifying installation.
Control Techniques Focus 3 provides flexibility. You can
stock the complete product line with the four chassis
units (two regenerative and two non-regenerative) and
two enclosure kits.

Analog DC Drive

1/4 to 5 hp, 1 phase, 115-230 VAC

Non-regen and Regen models

Isolated control circuit (Regen)

NEMA 4/12 or Chassis

Tachometer or armature feedback

Complete Motor Solutions

Conveyor
Rugged

Focus 3

6
7

1
8 9 0

0 1 2

3 4 5

FO
CU
S

FOCUS CHASSIS

F3N2C

F3R2C
F3N5C

F3R5C

271

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

www.emersonct.com
800-893-2321

RATINGS: FOCUS 3
SINGLE PHASE INPUT
.25 to 1 hp (115 VAC)
.50 to 5 hp (230 VAC)

FEATURE/PERFORMANCE ADVANTAGE
Surface mount design
Provides rugged and reliable operation at a costeffective price
NEMA 4/12 enclosure as standard
Protects the integrity of the drive in tough,
demanding environments
Regenerative and non-regenerative models available in the
same footprint
Minimizes machine design variations

Focus 3

Jumper programmable for:


Voltage rating (115-230 VAC)
Frequency (50/60 Hz)
Speed or torque control
Tachometer or armature feedback
Inherent flexibility in the drive design meets
numerous customer requirements with a minimal
inventory of drive models and options
Independent acceleration and deceleration rates
Adaptable to many machine and process speed
control requirements
Speed and current loop stability adjustments
Precisely matches the drive to the motor dynamics

Non-regenerative
Motor
HP
.25 to 1
.50 to 2
.25 to 1
.50 to 2
3 to 5
3 to 5

Input
AC Amps
Volts
115 14
230 14
115 14
230 14
230 35
230 35

Model

Order
Code

Chassis

F3N2C

NEMA 4/12

F3N2E

Chassis
NEMA 4/12

F3N5C
F3N5E

Model

Order
Code

Chassis

F3R2C

NEMA 4/12

F3R2E

Chassis
NEMA 4/12

F3R5C
F3R5E

Output
DC Volts
Amps
Arm

Field Arm Field

90
180
90
180
180
180

100
200
100
200
200
200

10
10
10
10
25
25

1
1
1
1
1
1

Regenerative
Motor
HP
.25 to 1
.50 to 2
.25 to 1
.50 to 2
3 to 5
3 to 5

Input
AC Amps
Volts
115 16
230 16
115 16
230 16
230 40
230 40

Output
DC Volts
Amps
Arm

Field Arm Field

90
180
90
180
180
180

100
200
100
200
200
200

10
10
10
10
25
25

1
1
1
1
1
1

Focus 3 is available with factory installed modifications.


To order choose the drive required from the table below
and then add modification suffixes to the order code
(separated by hyphens).

Separately adjustable jog speed


Aids the customer in setting up and testing their
machine
Auto (current/voltage signal) or Manual (speed pot)
operation
Provides local or remote speed control without an
option kit
Isolated control circuit (regen)
Signal common can be earth grounded and tied
directly to other drives without additional isolation

Order String
F3

xx

xx
Modification 2, etc.

Modification 1
C = Chassis, E = Enclosed
Drive Horsepower: 2 = 2 hp, 5 = 5 hp
N = Non-regen, R = Regen
F3 = Focus 3 Product Family

272
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

www.emersonct.com
800-893-2321

Focus 3

TERMINAL DIAGRAM: FOCUS 3

TERMINAL DESCRIPTION
Pin #
1
2
3
4
5
6
7
8

Type
+24 VDC Power Supply
Tie Point (motor thermal)
Run Relay
Relay (N.O.)
Relay Common
Relay (N.C.)
Jog Reference Select
(Logic Input)
Jog Pot Supply Input

9
10
11
12

+10 VDC
Speed Reference
-10 VDC (regen only)
Circuit Common

13
14

Minimum Speed Pot


Remote Current Limit Pot
Input
Remote Current Limit Pot
Input
Auto / Manual Input
Current follower Input
Voltage follower Input
DC tachometer Input (-)
DC tachometer Input (+)

15
16
17
18
19
20

Notes
For drive use only
No internal connection
+24 VDC @ 10 mA
Run relay contact
120 VAC, @ 1A resistive
+24 VDC, 30k Ohms
(requires run input)
Analog Input, 10 VDC
(-10 VDC regen only)
Reference Supply, 5 mA max
Analog Input, 10 VDC, 20k Ohms
Reference Supply, 5 mA max
Circuit common hot to earth
ground (non-regen only)
For use with speed pot only
Wiper input (refer to
Jumpers JP6 & JP7)
CW connection
(refer to Jumpers JP6 & JP7)
Logic Input, +24 VDC @ 30k Ohms
Analog Input, 4-20 or 1-5 mA
Analog Input, 200 VDC max
Analog Input, 160 VDC max
Circuit common

273
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

www.emersonct.com
800-893-2321

SPECIFICATIONS: FOCUS 3

DIMENSIONS

Adjustments
Maximum Speed

80 to 120% of rated speed

Minimum Speed

0 to 30% of maximum speed

IR Compensation

0 to 20% of rated voltage

Current Limit

0 to 150% of selected range

Acceleration

0.3 to 20 seconds

Deceleration

0.3 to 20 seconds

Jog Speed

0 to 30% of rated speed

Operator Functions
Speed Adjustment
Start/Stop

Standard
Standard (Enclosed)
Customer Supplied (Chassis)

Run/Jog

Option Kit

Forward/Reverse (Regen Only)

Option Kit

Auto/Manual

Option Kit

Customer Selectable
Rated Input Voltage

115 or 230 VAC

Control Mode

Speed or Torque

Output Current

Hi / Med / Low / Xlow

Armature Voltage Feedback

Hi (180) / Lo (90) VDC

Tachometer Feedback
Speed Feedback Selector
Line Frequency

Focus 3

Current Limit Pot Selector

Hi / Lo
Armature / Tachometer
50 / 60 Hz
Local / Remote

Control
Logic Control Power

24 VDC

Speed Potentiometer

5k Ohms, 2 watts

Speed Regulation
(95% load change):
Armature Voltage Feedback

Tachometer Feedback (i.e. 5PY)

1% of maximum speed with IR


compensation. (does not include drift
due to field)
0.5% of base speed

Drive Operating Conditions


NEMA 4/12 Enclosure
Altitude
Ambient Temperature
Rated Input Voltage
Rated Frequency
Overload Capacity

Standard (Enclosed)
Option Kit (Chassis)
1000m (3,300 ft)
0 to 40C (32 to 104F) (Enclosed)
0 to 55C (32 to 131F) (Chassis)
115-230 VAC 10%
48 to 62 Hz
150% of selected rating

Efficiency:
Controller (min)

98%

Drive (typical)

86%

274
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

www.emersonct.com
800-893-2321

Focus 3

M CONTACTOR KIT

FACTORY INSTALLED MODIFICATIONS


Focus 3 Kits are available as either factory-installed options
or field kits. To order factory installed modifications,
choose the basic drive required from the ratings table on
page 272 and then add modification suffixes (separated
by hyphens) to the basic order code.
Function

Description

Suffix

M
.25 - 1 hp @ 115V
Contactor Kits* .50 - 2 hp @ 230V
3 - 5 hp @ 230V
.5 hp @ 115 V, 2 hp @ 230V
Dynamic
.25 - .33 hp @ 120V, 1.5 hp @ 230V
Braking
.75 - 1 hp @ 230V
Kits
.5 hp @ 230V
.75 - 1 hp @ 115V
3 hp @ 230V
5 hp @ 230V
Toggle
Run / Jog
Switches
Auto / Manual
Forward / Reverse
Signal
Signal Isolation Board
Isolation
Feedback
AC Tachometer Input Board
Speed Pot
Ten-Turn Potentiometer

M1
M2
M5
DB2
DB4
DB6
DB7
DB1
DB3
DB5
TSA
TSB
TSC
NS
ACT
TTP

* When the M kit is factory installed, UL will not apply.

ENCLOSURE OPTIONS
By stocking these two enclosure kits
along with the four chassis drives,
the distributor can supply all Focus 3
models. The enclosure kits include the
speed pot and the start/stop switch
pre-wired to a plug-on terminal
strip and all gasketing required for a
NEMA 4/12 rating.
Description

Order Code

2 hp, non-regen and regen

F3SE

5 hp, non-regen and regen

F3LE

TOGGLE SWITCH (F3TS)


This kit is used to provide one of the following functions:
Run/Jog, Auto/Manual or Fwd/Rev (regen only). It can be
mounted in the Focus 1 or Focus 3 enclosure cover, or
remotely mounted when used with the chassis drive. The
F3TS kit includes the toggle switch, NEMA 4/12 switch
boot and connection wires for enclosure cover use. A
maximum of three kits may be used with the enclosure
cover.

This kit provides a positive


disconnect of the motor
armature when the controller
is stopped, preventing motor
rotation in the event of SCR
misfire due to line noise. It
includes the DB (dynamic
braking) poles, an auxiliary
normally open (N.O.)
contact, all connection wires
and a magnetic contactor
for mounting in the Focus
3 chassis or enclosed drives.
This kit may be required by
local and / or national electrical codes.
Description

Order Code

1 hp, 115 VAC

F3M112

2 hp, 230 VAC

F3M224

5 hp, 230 VAC

F3M524

Focus 3

Options

DYNAMIC BRAKING KIT


Dynamic braking provides rapid motor stopping by
quickly dissipating the stored energy in the rotating
motor and load. These kits are designed for use with the
Focus 3 contactor kits. The resistors have been sized in
accordance with the following NEMA specification for
dynamic braking: Three stops in rapid succession
with the load inertia equal to the motor inertia
then cooling forever.
AC Input

120 VAC

240 VAC

HP (Typical)

DB Kit
Order Code

.25 to .33
.5
.75 to 1
.5
.75 to 1
1.5
2
3
5

F3DB1524
F3DB224
F3DB112
F3DB0524
F3DB224
F3DB1524
F3DB224
F3DB324
F3DB524

275

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

www.emersonct.com
800-893-2321

Focus 3

TEN-TURN SPEED POTENTIOMETER

AC TACHOMETER INPUT
This option kit allows the Focus
3 to accept AC tachometer
feedback. It mounts directly to the
Focus 3 control board and accepts
a range of 45 to 110 VAC at
maximum speed.
Description

Order Code

AC Tachometer Input

F3ACT

SIGNAL ISOLATOR BOARD

This ten-turn speed


pot provides a vernier
scale for precise and
repeatable speed
setting while a
locking tab prevents
inadvertent speed
changes. It may be
mounted in the Focus
1 or Focus 3 enclosure, or in a remote operator station.
Description

Order Code

Ten-Turn Speed Potentiometer

6160-9001

Focus 3

This option is used in


applications where
isolation is required
between an external
control signal and the
motor controller (which
may or may not be at
earth ground potential).
It can be used to isolate a variety of voltage or current
signals (see specifications below) or simply to isolate
the speed potentiometer. The potentiometer power
supply is included. This option can be mounted inside
the Focus 3 cover or panel mounted on a piece of curtis
track (included with kit). Because the board has a unipolar output, it is typically used on single directional
applications.
Specifications
Input Power
Control Relay
Relay Contacts

17 to 30 VDC @ 50 mA max.
(for control circuitry)
24 VDC @ 12.1 mA (JP5 = 24 VDC)
115 VAC @ 20 mA (JP5 = 120 VAC)
(qty. 2) Form A, 1A @ 250 VAC

Isolation Voltage

240 VAC line voltage


2000 VAC hi-pot for 1 minute

Voltage Ranges

5, 12, 26, 52, 98 & 208 VDC


180 Ohms/volt

Current Ranges

0 - 5 or 1- 5 mA
910 Ohms input impedance
0 - 20 or 4 - 20 mA
250 Ohms input impedance

Speed Pot
Output

5k Ohms, 2 watts (includes


+10 VDC power supply for the pot)
0 to +10 VDC (uni-polar)

Description

Order Code

Signal Isolator Board

F3NSBD

276
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

You might also like