Earth Fault Relays

Earth Fault Relays with separate detection torroids These units ensure the protection of electrical installations. 30mA versions can provide supplementary protection against direct connection. This range of electronic earth fault relays provide monitoring of earth fault currents. When the fault current rises above the selected level, the output contacts of the product operate. Depending on the relay selected, it can have either fixed or adjustable sensitivity, a time delay is also available for selectivity purposes. The relays are linked with detection torroids, 14 separate types are available, circular and rectangular in section (3.26). Common characteristics Positive safety: the relay trips in the event of a break in the relay/torroid link. Positive reset required after a fault is detected. Test button for simulation of a fault. Protected against nuisance tripping from transients. DC sensitive. Output: 1 C/O contact 250V~ 6A AC1. Visual display of fault by red LED Features according to the selected devices Adjustment of sensitivity and delay (sealable). Extra positive safety contact (1C/O 250V~ 6A AC1). Display of fault current before it triggers the relay (5% to 75%). Extra output contact (250V 0.1A max.) to enable remote indication of fault currents over 50% of In. Remote test and reset by 3 wire link. Torroids Circular dia. 35, 70, 105, 140, 210mm Rectangular 70 x 175, 115 x 305, 150 x 350mm Connection capacity Relay - 1.5 to 6mm2 Relay - torroid link 2 wires, 25m max. Test and remote reset link 3 wires, 20m max. For enclosure selection, please consult us.

Earth Fault Relay


Designation Characteristics Width) (in 17.5mm) Cat ref.

HR400

Earth fault relay C/O contact 6A~ AC1 Earth fault relay C/O contact 6A~ AC1 Earth fault relay C/O contact 6A~ AC1 Adjustable sensitivity In = 30mA, 100mA, 300mA 1A,3A Earth fault relay C/O contact 6A~ AC1 Positive safety C/O contact 6A~ AC1 Adjustable sensitivity In = 30mA, 100mA, 300mA 1 & 3A Instant or time delayed 0.13 - 0.3 - 1 & 3 sec 6A~ AC1 Adjustable sensitivity In = 30mA, 100mA, 300mA 1 & 3A Instant or time delayed 0.13 - 0.3 - 1 & 3 sec Earth leakage relay with integral torroid adjustable sensitivity Earth leakage relay with integral torroid adjustable sensitivity instant or time delayed

Instant trip, fixed sensitivity In = 30mA Instant trip, fixed sensitivity In = 300mA

2 Mod 2 Mod 2 Mod

HR400 HR402 HR403 HR410 HR411 HR420

Instant trip or time delay 0.13 - 0.3 - 1 & 3 sec Standard version Version with LED optical scale

3 Mod 3 Mod 3 Mod

Version with LED optical scale and remote test

5 Mod

HR425

4 Mod 6 Mod

HR440 HR441

HR420

3.25

Hager General Catalogue 2009 Protection Devices