PD 957
PD 957
PD 957
A. Site Criteria
1. Location
Conformity with Zoning Ordinance/Comprehensive
Land Use Plan
Subdivision projects shall be located in residential
zones or other areas appropriate for residential uses. If
there is no Zoning Ordinance or approved Comprehensive
Land Use Plan, the dominant land use principle and site
suitability factors cited herein shall be used in determining
suitability of a project. Subdivision projects supportive of
other major urban activities (e.g. housing for industrial
workers) may be allowed in area zoned for the said urban
activities.
2.Physical Suitability
Subdivision projects shall be located within suitable
sites for housing and outside hazard prone areas and
protection areas as provided for by pertinent laws. Critical
areas (e.g. areas subject to flooding, landslides and those
with unstable soil) must be avoided.
The site shall be stable enough to accommodate
foundation load without excessive earthmoving, grading or
cutting and filling.
3. Accessibility
The site must be served by a road that is readily
accessible to public transportation lines. Said access road
shall conform with the standards set herein to
accommodate expected demand caused by the
development of the area. In no case shall a subdivision
project be approved without the necessary access
road/right-of-way. Said access road right-of-way may be
constructed either by the developer or the local government
unit.
B. Planning Considerations
1. Area Planning
Planning and designing of subdivision projects shall
take into account the following:
a. safety and general welfare of the future occupants:
b. adequate, safe, efficient and integrative road circulation system
servicing every lot therein;
c. judicious allocation of land uses for diversity and amenity;
d. preservation of site
e. proper siting or orientation of lots;
f. harmony with existing and proposed development in the vicinity;
g. Application of workable design principles or parameters for a
c. Density
Density of subdivision projects shall conform with the
residential densities set forth in the zoning ordinance of the
city/municipality where project is located. Where there is a
mixture of housing types within the subdivision (such as
single-detached, row house, town houses, etc.), density
shall include the total number of dwelling units in multistorey structure plus the total number of lots intended for
single and semi-detached houses.
2. Site Preservation
a. Slope
The finished grade shall have a desired slope to allow
rain water to be channeled into street drains. Where cut
and fill is necessary, an appropriate grade shall be attained
to prevent any depression in the area.
Grading and ditching shall be executed in a manner that
will prevent erosion or flooding of adjoining properties.
c. Ground Cover
Grass, shrubs, plants and other landscaping materials
used for ground cover shall be of a variety appropriate
for its intended use and location. They shall be planted so
as to allow well-tended cover of the area.
3. Easements
bodies;
b. National Power Corporation (NPC), on transmission lines;
c. PHIVOLCS per Resolution No. 515, Series of 1992, on
identified fault traces;
d. Other public utility companies and other entities' right-ofway;
e. National/local government units for projects abutting
national roads (primary roads) where adequate easement
shall be provided for, including loading and unloading areas;
f. Other related laws.
4. Circulation
far as practicable
Where a proposed project adjoins a developed property,
roads within the said project shall be
connected/integrated/aligned with existing ones.
Where a proposed project adjoins undeveloped
property, a provision for future connection shall be
mandatory.
C. Design Parameters
1. Land Allocation
For open market and medium cost subdivision projects
with an area of one (1) hectare or more, the percentage
(%) allocation of land shall be as follows:
a. saleable area maximum of 70% of the gross area
b. non-saleable area minimum of 30% of the gross
area
2. Lot requirements
a. Lot Layout:
c. Lot Design
C.1 Saleable lots shall be designed such that they are not
bisected by political boundaries, water courses, drainage ways
and utility lines.
C.2 A lot shall be served by an independent access road.
C.3 Whenever possible, lot frontage elevation shall be at street
level.
C.4 Lot lines shall preferably be made perpendicular to street
lines.
C.5 Deep lots and irregularly shaped lots shall be avoided.
C.6 Lots shall be planned with adequate width for side yards.
C.7 Lots shall be protected against risks.
C.8 Lots shall not be laid out if potential risks exist e.g. erosion,
slides, flooding, fault lines, etc.
d. Lot Frontage
The minimum lot frontages for various types of housing under open
market and medium cost housing projects shall be as follows:
3. Length of Block
Maximum length of block shall be 400 meters, however,
blocks exceeding 250 meters shall be provided with an alley
approximately at mid-length.
4. Shelter Component
a Minimum floor area for open market housing shall be 42
square meters and 30 square meters for medium cost
housing.
b. Minimum level of completion - complete house for all
types of dwelling units based on the submitted specifications.
Provision of firewall shall be in conformity with the Fire Code
of the Philippines and mandatory for duplexes/single attached
units and every unit for rowhouses.
5. Yard/Setback
The minimum setback of dwelling units both for open
market and medium cost housing projects shall conform to
the National Building Code of the Philippines.
6. Water Supply System
a. Specific Rules:
The subdivision water supply shall be mandatory or
obligatorily connected to an appropriate public water
system or community system provided that the water
supply is enough to meet the total daily requirements of the
anticipated population.
b. Water Requirement
Every dwelling unit shall be served by an individual
supply of water sufficient to meet the total hourly domestic
needs of every household for any 8 hour period.
The Average Daily Demand (ADD) for both open market
and medium cost housing projects is 150 liters per capita
per day (LCPD) household
connection. (Per Board Resolution No. 506, series of 1992)
b. Septic Tanks
Where community sewer system is not available,
sewage shall be disposed of and treated in individual septic
tanks.
Construction of individual septic tanks shall conform to
the design standards of Sanitation Code of the Philippines
(PD 856) and National
Plumbing Code of the Philippines (RA 1378).
9. Drainage System
The drainage system of the subdivision shall conform to the
natural drainage pattern of the subdivision site, and shall drain
into appropriate water bodies or public drainage system. In no
case shall drainage outfalls drain into a private lot. Its layout
shall conform to sound engineering design/ principles certified
by a duly licensed civil/sanitary engineer. Drain lines shall be of
durable materials and approved installation practices.
For both open market and medium cost subdivision
projects, underground drainage system shall be properly
engineered and environmentally sound and shall be provided
with adequate Reinforced Concrete Pipes (RCP), catch basins
manholes, inlets and cross drain for efficient maintenance.
Minimum drainage pipes diameter shall be 30 centimeters.
Planning and
Design
Standards
for a Residential
Subdivision
Project
Under PD 957
A. Site Criteria
Conformity to Comprehensive Land Use Plan/Zoning
Ordinance/National Building Code
1. Residential condominium projects shall preferably be
located in areas zoned as or appropriate for residential
uses.
2. Condominium projects shall likewise conform to the
minimum building requirements, lot occupancy, open
spaces, parking and other requirements of the National
Building Code of the Philippines and its Implementing
Rules and Regulations.
B. Planning Consideration
1. Area Planning
a. Supplementary and supportive activities to residential use
shall be allowed provided that the privacy, order, health and safety
of the residents are not jeopardized nor threatened and that the
land use plan and/or zoning ordinance of the locality can
accommodate such mixture of land uses.
b. Open spaces shall be provided within the project site
pursuant to the National Building Code of the Philippines and its
Implementing Rules and Regulations. These shall include courts,
yards, setbacks, light wells, uncovered driveways, access roads,
parking spaces, buffer strips, parks and playgrounds. Except as
may hereafter be otherwise provided these spaces shall be open
from the ground to the sky. The open space shall also be allocated
for basic utilities and community facilities or common areas.
2. Site Preservation/Alteration
a. Slope
The finished grade shall have a desired slope to allow rainwater
C. Design parameters
1. Space location
Space allocations shall provide areas for living, dining,
kitchen, sleeping, toilet and bath, laundry/ drying area and
storage -the minimum sizes of which shall be in
accordance with the requirements of the National Building
Code of the Philippines and its Implementing Rules and
Regulations/referral codes.
c. Access Roads
Roads
such services areas are held in common, they shall have suitable
outdoor locations, fenced or screened and kept away from living
rooms, entrance or front yards.
d.2 Water supply, power, sewerage and drainage utilities shall
conform to the requirements of a subdivision.
d.2.1 Reservoir/Water Tank
For multi-storey buildings.If the height of the building requires
water pressure in excess of that in the main water line, a water
tank shall be provided. Tank shall also be required if the peak
drawn should reduce the pressure on the highest usable floor to
less than 0.06 Mpa the minimum pressure required for
satisfactory operation of fixtures, particularly those with flush
valves.
however, a net floor area of 12 square meters may be allowed provided that:
a.1 These are intended for students/employees/workers and provided further
that the condominium project to which these will be integrated is within highly
urbanized areas.
a.2 The same shall be provided with common basic facilities such as
laundry/drying area and support amenities such as visitor's lounge and dining
area.
a.3 Said facilities/support amenities including all other measures that will
ensure compliance with the intended use of the unit shall be explicitly
indicated in the master deed/ contract to sell.
b. Family Dwelling Unit
The minimum floor area of family condominium units shall be 36 square meters
and 22 square meters for open market and medium cost condominium project
respectively.
Section 4. Variances
These
1. The location is unique and different from the adjacent locality, and
RULE II
APPROVAL OF SUBDIVISION PLAN
2. One (1) set of the following documents duly signed and sealed by a
and
g. For new corporations (3 years and below) statement of
capitalization and sources of income and cash flow to
support work program.
10. Plans, specifications, bills of materials and cost
estimates duly signed and sealed by the appropriate
licensed professionals.
11. Application for permit to drill from the National Water
Resources Board (NWRB).
12. Traffic impact assessment (TIA) for subdivision projects
30 hectares and above.
13.
project and prepare the survey returns with technical description and
computations duly signed and sealed by a licensed geodetic engineer
to be submitted together and in accordance with the approved
subdivision plan, to the Land Management Sector (LMS) for
verification and approval; pursuant to Section 50 of PD 1529
(Property Registration Decree) and sections 4 & 5 of PD 957 and
subject to the provisions of RA 8560 and its implementing rules and
regulations.
RULE IV
REGISTRATION AND LICENSING OF
SUBDIVISION AND CONDOMINIUM
PROJECTS
A. Common Requirements
The owner or the real estate dealer interested in the sale of
lots or units in a subdivision project or condominium project,
respectively, shall register the project with the Board by filing
the following:
1. Sworn Registration Statement using either:
a. HLURB Form 001 for Corporation; or
b. HLURB Form 003 for Single Proprietorship
2. Certified True Copy of Transfer Certificate of Title (TCT) or
b. When certified copy of the TCT was issued more than one
month prior to the application for Certificate of Registration
(CR), affidavit of the owner that the property is free from liens
and encumbrances. When the applicant is not the owner,
deed from the registered owner showing clearly the authority
of the applicant to the property, e.g., its development and sale
of individual lots or units; to sign and receive documents; and,
other relevant authority. In case the subdivision/condominium
project or portion thereof is mortgaged, affidavit of undertaking
to submit title; certification from the mortgagee regarding
outstanding balance of loan and amortization schedule;
mortgage of contract; and, affidavit of undertaking of
mortgagor
B. Additional Requirements
1. For Condominium Projects
a. Master Deeds with Declaration of Registration and
B. Additional Requirements
2. For Subdivision Projects:
a. 2 copies of verified survey returns with label for all non-
B. Additional Requirements
b.1 Sangguniang Resolution/Ordinance granting of development
permit/ subdivision development plan containing the following
information:
b.1.1 full name of the grantee or permittee and his address;
b.1.2 complete project name and its location;
b.1.3 date of the resolution or ordinance;
b.1.4 project area;
b.1.5 full listing of title(s) covering the project;
b.1.6 legal basis of the approval (PD 957, EO 648 and other
related laws);
b.2 Certified true copy of resolution conferring authority to the mayor
or other local government official to issue development permit in
cases where the same was not granted by the Sangguniang
Pangbayan/Panlungsod.
filing of registration
statement within two (2) weeks from receipt of notice to
publish issued by the Board, the owner/developer shall be
required to re-file the application for Certificate of
Registration.
RULE V
REGISTRATION OF REAL ESTATE DEALERS, BROKERS AND
SALESMEN
RULE VI
MISCELLANEOUS PROVISIONS
DEFINITION OF TERMS
For purposes of these rules, the following words and phrases are defined:
a. Board or HLURB -shall mean the Housing and Land Use Regulatory Board.
b. Block a parcel of land bounded on the sides by streets or alleys or pathways
or other natural or man-made features, and occupied by or intended for
buildings.
All lands fronting on one side of a street between the nearest streets,
intersecting, meeting or crossing the aforesaid street.
c. Commercial Condominium a building, or group of buildings, used for office,
businesses, professional services and other commercial enterprise organized,
owned and maintained as a condominium.
d. Common Areas -means the entire project excepting all units separately
granted, held or reserved.
e. Community Facilities -facilities or structures intended to serve common
needs and for the benefit of the community such as schools, places of
worship, hospitals, health centers, barangay centers and other similar
facilities/amenities per PD 1216.
DEFINITION OF TERMS
f. Condominium shall mean an interest in real property consisting of a
ownership and all floor space, facilities and outdoor areas used in
common by all tenants are owned, administered and maintained by a
corporation created pursuant to the provisions of the appropriate statute.
DEFINITION OF TERMS
a. The units comprise not only the space enclosed by the unit
boundaries, but all material parts of the land within the space;
b. The common element means all the property within the development
except the units;
c. The common element is owned by all of the owners as tenants in
common.
A building or group of buildings, in which units are owned individually, and
the structure, common areas and facilities are owned by the owners on a
proportional undivided basis.
g. Condominium Project means the entire parcel of real property divided
or to be divided in condominium, including all structures thereon.
h. Condominium Unit -means a part of the condominium project
intended for any type of independent use or ownership, including one or
more floors (or part or parts of floors) in a building or buildings and such
accessories as may be appended thereto.
DEFINITION OF TERMS
i. Dealer -shall mean any person directly engaged as principal in
DEFINITION OF TERMS
Dwelling Types:
1. Single Detached -a dwelling unit completely surrounded by yards.
2. Single Attached -a dwelling unit with one side attached to a firewall.
3. Duplex -a dwelling unit containing 2 separate living units each of
DEFINITION OF TERMS
n. Living Unit -a dwelling, or portion thereof, providing complete living
DEFINITION OF TERMS
p. Medium Cost and Open Market refers to housing