Control & Protection Solutions: Control Systems & Products For Process, Engines, Compressors and Pumps
Control & Protection Solutions: Control Systems & Products For Process, Engines, Compressors and Pumps
Control & Protection Solutions: Control Systems & Products For Process, Engines, Compressors and Pumps
solutions
• 3 manufacturing facilities
• Over 60 distributors
AMOT’S SERVED MARKETS
OUT A
Diverting
Mixing B
IN A
C
Exploded view of a TCV
Bypass Cooler
B C
A
Inlet
Wax element inside TCV
Temp. sensing Elements
Wax Element operation
Working principle
Thermostatic valves
Valve selection
• FLUID TYPE
• FLOW RATE
• Cast Iron
• H2O, H2O & glycol, oil
• Lowest cost
• Aluminum
• Oil, H2O & glycol
• Low cost
• Bronze
• Deionized H2O, salt water
• Highly flexible, shipboard
• Buna N (Nitrile)
• H2O, H2O & glycol, Oil
• Viton
• Synthetic oil
• Neoprene
• Refrigeration
• Ammonia
• Freon
Model Code
3BOCF16501
MODEL CODE SYSTEM
3 BO C F 160 01 - ___ - ( )
Special Requirements, (MTO) Made-To-Order
Element Assembly Leak Hole, See Table G
Element Assembly Type, See Table F
Temperature Setting, See Table E
TABLE D*
TABLE A TABLE B TABLE C Connections
Valve Size Valve Type Body Material Code No. Type
Inches (mm) Code No. Code No.Material
F ANSI B16.1 (125 lb. Class) "FF Flange"
1-1/2 (40) BO Standard C Cast Iron J ANSI B16.5 (150 lb. Class) "RF Flange"
2 (50) BM Manual Override S Steel H ANSI B16.34 (300 lb. Class) "RF Flange"
2-1/2 (65) BC Tee config, Flanged B Bronze K ANSI B16.37 (600 lb. Class) "RF Flange"
3 (80) 1-1/2, 2" only D Ductile Iron A AMOT MET 1 (ND6) "90 psi Metric Flange"
4 (100) BF Flanged, 2" only R Stainless B AMOT MET 2 (ND10) "150 psi Metric Flange"
5 (125) BH 1-1/2, 2" only Steel C AMOT MET 3 (ND16) "235 psi Metric Flange"
6 (150) BE Low flow, 4" only N Navy Flange per MIL-F-20042
P JIS 5K "FF Flange"
T Threaded NPT to USAS B2.1 (standard)
V Threaded BSP (Tr) and Japanese JIS
W Threaded to SAE J514h straight thrd O-ring seal
Nominal Temperature
Model Code
3BOCF165 01
TABLE E TABLE E (Continued)
Temperature Setting Temperature Setting TABLE F TABLE G
Code Nominal Temp Code Nominal Temp Element Assembly
No. °F (°C) No. °F (°C) Element Assembly Leak Hole
Code No. Type Code Size
*055 55 (13) 160 160 (71) No. Inches (mm)
075 75 (24) 165 165 (74) 01 1096X Standard
090 90 (32) 170 170 (77) 02 1096P Plated with Viton none (standard)
095 95 (35) 175 175 (79) 03 1096X with Viton seals
180 180 (83) 07 2433X Manual Override A 1/2" (12.5)
100 100 (38)
185 185 (85) 11 5566X Reduced stroke B 1/4" (6.4)
105 105 (41)
195 195 (91) 05 6836S Saltwater C 3/8" (9.5)
110 110 (43) 205 205 (96)
115 115 (46) 44 1096X with Neoprene D 1/8" (3.2)
215 215 (102) 45 1096P with Neoprene E 1/16" (1.6)
120 120 (49) 225 225 (107) 20 5566X with Viton F 3/32" (2.4)
*130 130 (54) 230 230 (110) 12 5566P Plated G 3/16" (4.8)
135 135 (57) 235 235 (113) 53 2433X with Viton H 5/16" (7.9)
140 140 (60) 240 240 (116) 50 6836K Kanigen with
145 145 (63) Temperatures apply only Neoprene
*150 150 (66) to 1096 and 2433 Element * = Also avail. as reduced stroke. Contact factory for other temps.
155 155 (69) Assemblies. Indicates Non-Standard, Special Charge
Serviceable Parts
• Temperature element
• Service kits
• Buna N or Viton O rings and gaskets
THERMOSTATIC CONTROL VALVE
• Slow response.
• Fit & Forget solution.
ACTUATED TYPE
Model G
Temperature Control Valves
AMOT Features
• Compact Size
versus other actuated valves
• Sizes
• 50 to 450mm
• Materials
• Cast Iron
• Ductile Iron
• Bronze
• Steel
• Stainless Steel
Mixing application
Diverting Application
Marine Cooling System
Marine Cooling System
Charge Air
(LT) Temperature Control
Typical Applications
• Fluid types
• Fresh water / Lube oil / Sea Water
• Flow rate
• Maximum possible temperature (120°C)
• If likely to exceed 100°C then Viton should be used
• Fast Response
• Reliable Operation
System Components
• Valve
• Actuator
• Controller
• Temperature sensor
• I/P converter
G Valve - Electrical
Valve
• Rotary Valve
• Mixing or
Diverting
Rotary Valve Design
CFD Model
• Open loop
• Panel mounted
• Inputs:
• 3 wire RTD
• 4–20mA
• Outputs:
• 4-20mA
• Logic outputs
• CE marked
• Enclosure Houses
• 8071D
• 2 off solid state relays
• Fuses
• On / Off switch
• Wiring connections
• IP67 Enclosure
protection
Temperature Controller
• IP67 enclosure
protection
• Screw connections
8064A7716-AA
I/P Converter
• Bulkhead mounting
• Input signal 4 - 20mA
• Output signal 3 - 15 psi
• For use as an interface between
8071D temperature controller
and the pneumatic G valve on
the electro - pneumatic system.
• Stainless Steel
• Corrosive environments (offshore)
• Corrosive fluids
Flanged connection
• Flanged 2” –16” ?
• DIN
• ANSI
• JIS
Mode of Operation
• Electric
• Pneumatic
• Electro-pneumatic
Electric System
• Accurate control
• Not fail-safe
Pneumatic System
• Fail-safe
• Will fail to a safe condition
• Old fashioned
• Inaccurate sensing
• Due to capillary
• Difficult to commission
Electro Pneumatic System
Manual Override
• Features:
• High reliability feedback
potentiometer
• Limit switches, Torque
switches plus 2 auxiliary
micro-switches
• Vibration resistant
terminals
• 4-20mA positioner
option.
EA Series Actuator – 4-20mA
Positioner
• Features:
• Position control using 4-
20mA demand
• 4-20mA configurable re-
transmission output
• Internal 4-20mA loop
power supply
• Several interface
configurations possible
• Status LED and two-state
error output
• Solid State power
switching
Configurator 47962X
Calibration / Configuration
GPD – Pneumatic Actuator
• Positioner
• Actuator
• Manual override
(Optional)
GPD – Pneumatic Actuator
GPD – Pneumatic Actuator
• Accessible location
• To enable easy inspection and service
AMOT GED Valve Installation
PT100 Sensor
PID Controller
Oil
In
• Continuously samples oil
• Oil enters top of MPD
• Oil travels through grid
• Oil exits bottom of MPD
Grid
Oil
Out
Theory of operation
Block
Valve
Gas Engine
MPD
Orifice
Block
To Engine
Valve
Bearings,
To Engine Oil Sump
Etc.....
Bleed
Pump Valve
Main Oil Supply Line Filter
Flow
• Install in side stream of main oil supply line Side Stream
• After pump, before filter, in bottom of oil line
• Install above crank case, if possible
• Install block valves before and after the MPD- use a bleed valve with the outlet block valve
• Use an adequate size orifice on the outlet of the MPD to prevent starving the equipment of
oil
• Oil exits MPD into sump
AMOT offers
AMOT offers
the
the World’s Most
World’s Most Complete
Complete Line
Line of
of
Rotating
Rotating Equipment
Equipment Sensors
Sensors && Safety
Safety Controls
Controls !!!!
GAS
Master safety shut down
• Anodized Aluminum
• Hydraulic or Pneumatic
1672 – Pressure sensing valve
• Measurement Principle:
Adjustable pressure switch, actuated by sensed pressure against
a diaphragm or piston operator. The set point is controlled
by the sensed area, and by replacing / adjusting the spring.
• Applications:
Pressure Sensing on
• Compressor Suction / Discharge Lubricating Oil
• Cooling Water Combustion Air
• Control Air Fuel Oil
• Fuel Gas Starting Air
• Key Features:
• Easy Field Adjustment, used in both Hydraulic or Gas
Systems, Factory Set, Gulfproofed, Pneumatic Lockout
available (Range 1).
Temperature valves
2230, 4021, 4075 & 4087
2230 / 4430 Two Way Temperature Sensing
Valve
•2.75”,3.5”,5.5”,7”,& 8” Ø
•Anodized Aluminum
Body
•Pneumatic,Hydraulic, or
Electric actuator
•( no 4”)
4262
4” and 6” Ø Only
Same Actuators as 4261
Broader hose bib mounts
Fuel shutoff / Air start valves
• Principle of Operation
• Pressurize pilot port to open inlet to outlet and close vent
• Remove pressure from pilot port to stop flow across valve
and open vent to outlet
x
Pilot Pilot
Pressure Pressure
Vent Vent
Air / Gas start up valves
• Suitable for
Slow Speed 2
stroke engines
• Speed range of
20 to 250rpm
Thank You