A

PRESENTATION ON
MEDHA ELECTRONIC INTERLOCKING
COURSE DIRECTOR SIR
SHRI K UMA MAHESWARA RAO
(APS)
PRESENTED BY :-
VINAY KUMAR SINGH
PROJECT GUIDE
APP JE SIGNAL/SUR/CR ADSTE/KLBG/SUR/CR
ISJE/02/04/2021/BATCH-4 SSE/SIG/KLBG/SUR/CR
ROLL NO. 50
CONTENTS
1 WHAT IS EI ?
2. WHY EI ?
3. WHY MEDHA EI ? ( ADVANTAGES )
4. WHERE IT CAN BE USED ?
4. POWER SUPPLY DISTRIBUTION
6. HOW EI SYSTEM WORKING ?
5. BUILDING BLOCKS
6. CIU’S ,OC’S CARDS , PP’S CARDS
7. COMMUNICATION BETWEEN VARIOUS CARDS
8. RING MODEM CONFIGURATION
9. FAT TESTING PROCEDURE
10. FAILURES
WHAT IS EI?

 Electronic Interlocking (EI) system is a Microprocessor based


interlocking equipment reads the field and panel inputs and process
them in a fail-safe manner as per logic and generate required field
outputs and panel outputs.
WHY EI?
1. EASY INSTALLATION AND MAINTENANCE
2. REDUCTION IN RELAYS ( BY 60 % APPROX )
3. SPACE SAVING ( BY 50% APPROX )
4. REDUCTION IN POWER CONSUMPTION ( BY 30% APPROX )
5. REDUCTION IN FAILURES ( BY 66% APPROX )
6. REDUCTION IN COPPER CABLE REQUIRED
7. RELIABILITY,AVAILABILTY,FAILURE OF SAFER SIDE, REDUNDANT
8. LESS PRONE TO SHORTCUT ( VCOR DROPS )
9. ALTERATION REQUIRED ONLY CARD CHANGE ( ONE BLOCK)
10. SIMPLER AND FASTER OPERATION WITH VDU
11. INBUILT EVENT LOGGING AND DIAGNOSTIC
12. NO AIR CONDITIONG REQUIRED COMPATIBLE WITH AC RE AREA.
MEDHA EI ADVANTAGES

 FULLY INDIGENEOUS ( MAKE IN INDIA )


 FASTER RESPONSE TIME ( < 3 SEC FOR ANY YARD SIZE )
 2 OUT OF 2 REDUNDANCY
 CENTRAL MODIFICATION NEEDED ONLY
 OFC Interface with Ring Configuration operating at 115.2 kbps
for PP/VDU Control Terminal, Object Controllers and EI
Cascading.
WHERE IT CAN BE USED ?
REDUNDANCY
1. 2 out of 2 architecture
2. 2 out of 2 system with hot
standby
3. 2 out of 3 architecture
4. Can be centralized or
distributed one.
POWER SUPPLY ARRANGEMETS
1. TWO DB’S DB1 ( 110V )
AND DB2 (24V).
2. ONE MINI IPS
3. TWO INDEPENDENT
POWER SOURCE USED.
4. 3 SEPARATE POWER
SUPPLY USED:-
TYPE A 4.5V/8AMPS
TYPE B 4.5V/3AMPS
TYPE C 4.5V/6AMPS
COMMUNICATION CABLE
1. CIU TO MT ( OFC)
2. CIU TO PP ( OFC)
3. OC TO CIU ( OFC)
4. I/P,O/P WFM TO OC
( RS485)
5. CIU TO CB ( OFC)
CENTRALISED ARCHITECTURE ( HOW
ITS WORKING ? )
DISTRIBUTED ARCHITECTURE
BUILDING BLOCKS
MEDHA EI
CENTRAL INTERLOCKING UNIT

Performs the Vital Interlocking


functions and Communicates
with the other Sub-Systems
OBJECT CONTROLLER
®

Acquiring the Vital


Field Input Data and
Driving the Vital Field
Outputs
PANEL PROCESSOR

Acquiring the Operator


Command Inputs and
Displaying the Yard Status
Indication to the Operator
VIDEO DISPLAY UNIT
®

It has the same


Functionality as
Panel
Processor unit
and CCIP
MAINTENANCE TERMINAL
®

Provides Information about Events


& Faults logging, Trouble shooting
and Diagnostic Information of
MEI633.
COUNTERS AND BUZZERS

Used to drive the


Counter and Buzzers
VARIOUS CARDS CIU , OC ,
PP
CENTRAL INTERLOCKING UNIT

®
FPD

CIU-TOPBIN Power
Supply Modules

CIU-BOTTOM BIN
Processor Modules

OFC-RS485
Ring Modem
Central Interlocking Unit
CIU TOP BIN

CH-A CH-B

CCPSB-A SPARE CVPSB-A SPARE SPARE CVPSB-B SPARE CCPSB-B


CIU TOP BIN

CCPSB-A CVPSB-A CCPSB-B


CVPSB-B

CH-A
CH-B
CIU BOTTOM BIN

CH-A CH-B

SPARE SPARE
CIF-A CVHM-A CCC-ACIF-B
CVC-B
CVC-A 2 IN
2 IN CCC-B CVHM-B NUMBER NUMBER
CIU BOTTOM BIN

CH-A CH-B

CIF
CVHM
CCC
CVC
OBJECT CONTROLLER

Acquiring the Vital


Field Input Data and
Driving the Vital Field
Outputs

Features
Consists of 5 I/P cards 3 O/P cards
It can handle upto 64 Input & Outputs
i.e 8x5 = 40 I/P’s, 8x3 =24 O/P’s = 64
OC TOP BIN

®
OC BOTTOM BIN

WFM-5 WFM-6 WFM-0 WFM-1 WFM-2 WFM-3 WFM-4


WFM-7

OCCO-1 ORLD-1 OCCO-2 ORLD-2 OCCO-3 ORLD-3 OVCO OCCI-1 OCCI-2 OCCI-3 OCCI-4 OCCI-5
OC BOTTOM BIN

®
HOW COMMUNICATION
HAPPENING THROUGH
VARIOUS CARDS?
PANEL PROCESSOR TO CIU AND OC
COMMUNICATION
BUTTON
PRESSED INDICATION

PPSB-A
PPOP

PPCC-A CIF-A/CIU-A OC-A

PPIP

CIF-B/CIU-B OC-B
PPCC-B

PPSB-B
COMMUNICATION B/W CIU & OC
24V
CH-A
CCPSB-A CVPSB-A
All OC's
PP
VDU CVHM-A

MT-A
DL-A
CIF-A CCC-A CVC-A FPD-A

MT-B
CIF-B CCC-B CVC-B DL-B
FPD-B

CH-B CVHM-B
All OC's
PP CVPSB-B
VDUw w w a i n d i a . CCPSB-B
c o m

24V
HOW ORLD CARD DRIVES RELAY ?
OPSB-A
OPSC-1 ALL I/P O/P CARD
CH-A
CIF
OVH-A

READ BACK
FROM F.C
USED
OICC-A

OCCO R1
O/P WFM ORLD
R2

OICC-B
OCCI
I/P WFM

OVH-B STATUS
FROM F.C
CH-B
CIF- OPSC-2 ALL I/P O/P CARD
B OPSB-B

w
HOW FIELD OUTPUTS CONNECTED ?
HOW FIELD INPUTS ARE CONNECTED ?
OC-OC RING CONFIGURATION
®
MASTER SLAVE CONFIGURATION
FAT TESTING
PROCEDURE
SIMULATION SETUP
DATA FLOW DIAGRAM
APPLICATION DATA DESIGN ( STAGE 1)
STAGE 2
STAGE 3
STAGE 4
MEDHA SOFTWARES NEEDED
VDU SAVALGI
MEDHA FSP
TYPES OF ALTERATION

MINOR ALTERATION
1. W/O ADDING ANY S/G ONLY LOGIC EQN CHANGE.

MAJOR ALTERATION
1. ADDING NEW S/G COMPLETE TESTING REQUIRED.
FAILURES
CRITICAL FAILURES
NON CRITICAL FAILURES
CRITICAL FAILURES

EI Shut Down – Without O/P Driving getting I/P


Status Eg: If receiving any off ECR without
corresponding O/P Relay (HR)
Power Supply Failure…… Fuse Blow,In sufficient
Battery bank Backup Voltage Etc
NON CRITICAL FAILURE
Relay Drive Fail ------- If Coils supply not available at Relay
(R1,R2 ) , When SystemDrives the supply

Output Relay Read Back Failure – Once Relay energized but


unable to read the front contact of the same

Input Relay Mismatch – Relay Energized & Unable to Read the


status of contact.
OC Shutdown - Forcibly Energizing the Output Relay
Communication Failure - Any Link failure RS485 /
OFC link